Anda di halaman 1dari 10

Hydraulic Excavator R 9350 Electric

Operating Weight
with Backhoe Attachment: 314,600 kg / 693,600 lb
with Shovel Attachment: 322,500 kg / 712,000 lb
Engine Output: 1200 kW / 1675 hp
Bucket Capacity: 15,30 – 18,00 m3 / 20.0 – 23.5 yd3
Shovel Capacity: 15,30 – 18,00 m3 / 20.0 – 23.5 yd3

TB R B E DIN i dd Uh
Uppercarriage R 9350 Electric
1
8

2 9

10
4

11
6

13

12

14

1 Catwalks 8 Swing Gear


2 Control Panel 9 Hydraulic Oil Coolers
3 Operator’s Seat 10 Hydraulic Tank
4 Cab 11 Hydraulic and Electric Rotary Connection
5 High Voltage Compartment 12 Splitterbox
6 Grease Container for Centralized Lubrication 13 Pumps
7 Low Voltage Compartment 14 Electric Motor

2 R 9350 Electric
Technical Data
Engine Hydraulic System
Incoming Supply Requirements Hydraulic pumps
Network power supply __ 3-Phase AC for attachment and
Voltage ______________________ 6000 Volts ± 10 % travel drive,
Frequency (standard) __ 50 Hz ± 1 Hz (or 60 Hz – dependent on country) max. flow __________________ 3016 l/min./797 gpm
Nominal excavator Max. working
power ________________________ 1250 kW pressure ____________________ 320 bar/4640 PSI
Average energy Hydraulic pumps
consumption ______________ 1000 kWh at S1 for swing drive,
(Other voltages available on request) max. flow __________________ 780 l/min./206 gpm
Electric Motor Specifications Max. working
Manufacturing pressure ____________________ 350 bar/5075 PSI
company ____________________ ALSTOM Pump regulation ______________ horsepower summation with pressure com-
Model ________________________ N3 RX 450 pensation, flow compensation, automatic
Type __________________________ AC squirrel cage motor oil flow optimizer
Number of motor ________ 1 Hydraulic tank capacity ______ 2200 l/581 gal
Output of one motor ____ 1200 kW at 1500 RPM Hydraulic system capacity __ 4200 l/1110 gal
(or 1800 RPM at 60 Hz) Hydraulic oil filter ______________ filtration of entire return flow, 1 high pres-
Power factor ______________ cos f = 0,88 sure filter for each main pump
Protection class __________ IP 55 EN 60529 Hydraulic oil cooler __________ with thermostatically regulated cooling fan
Isolation class ____________ F driven via hydraulic piston pumps
Motor cooling ____________ integrated air-to-air heat exchanger Lubrication ______________________ central lubrication system
Motor construction ____ IM 2001
Starting method __________ starting transformer

Electrical System Hydraulic Controls


the high and low tension cubicle are integrated with a robust
sheet steel construction Servo circuit independant, electric over hydraulic pro-
____________________
High Voltage Section ________ • Protection class IP 55 EN 60529 portional controls of each function
• Mechanical isolator switch on outside of Emergency control ______ via accumulator for all attachment func-
enclosure to disconnect high voltage for tions with stopped engine
maintenance Power distribution ____________ via monoblock control valves with inte-
• Electrically operated interlocks to dis- grated primary relief valves and flanged on
connect high voltage when enclosure secondary valves for travel
doors are opened Flow summation ________ to attachment and travel drive
• Main circuit breaker for protection against Control functions
short circuit, undervoltage and as emer- Attachment and
gency stop swing ________________________ proportional via joystick levers
• High voltage contactors for main motor Travel ________________________ proportional via foot pedals or hand levers
control Bottom dump bucket __ proportional via foot pedals
• High voltage current limiting fuses for
transformer primary protection
• Start transformer to reduce inrush current
• One three phase transformer: 6000 V/ Swing Drive
400 V for auxiliary components
• One three phase transformer: 6000 V/ Hydraulic motor ________________ 2 Liebherr axial piston motors
230 V for auxiliary components Swing gear ______________________ 2 Liebherr planetary reduction gears
• Three current transformers to drive Swing ring ______________________ Liebherr, sealed triple roller swing ring,
conventional motor protection relay internal teeth
• Thermostatically controlled fans and anti- Swing speed ____________________ 0 – 3.5 RPM
condensation heaters inside enclosure Swing torque ____________ 1120 kNm
Low Voltage Section ________ • Protection class IP 55 EN 60529 Swing-holding brake ________ hydraulically released, maintenance-free,
• Three phase transformer secondary pro- multi-disc brakes integrated in each swing
tected with circuit breaker and protected gear
against earth leakage
• Ground fault protection with leakage cur-
rent device
• Step down transformer 400 V/24 V AC Uppercarriage
net stabilized for bordcontrol
• Step down transformer 400 V/24 V DC for Design torque resistant designed upper frame in
____________________________
the control circuits box type construction for superior strength
• Motor protection relay for: and durability
– motor winding and bearing temperature Attachment mounting ________ parallel longitudinal main girders in box-
– overload section construction
– single phase Catwalks ________________________ on the left side with a hydraulically driven
– stalling access ladder, additional emergency ladder
– ground fault in front of the cab
– short circuit
– phase failure
– phase main motor sequence protection
for all hydraulic pumps and three phase
auxiliary drive
• Power supply for continuous monitoring
system
• Electrically operated interlocks to dis-
connect high voltage when enclosure
door are opened
• Thermostatically controlled fans and anti-
condensation heaters inside enclosure

R 9350 Electric 3
Technical Data
Service Flap Central Lubrication System
Design hydraulically actuated service flap, easily
____________________________ Type ________________________________ Lincoln Centromatic lubrication system for
accessible from ground level to allow: the entire attachment and swing ring
• hydraulic oil refill Grease pumps ________________ Lincoln Powermaster pumps with switch
• splitterbox oil quick change over function, plus 1 separate pump for
• swing gearbox oil quick change swing ring teeth
• windshield washer water refilling Capacity __________________________ 200 l/53 gal bulk container for attachment
• grease refill with filters for both containers and swing ring, separated 80 l/21 gal
• swing ring gearing grease barrel refilling grease drum for swing ring teeth
via grease filter
• attachment/swing bearing grease barrel
refilling via grease filter
Quick coupler upon request Attachment
Design box type structure with large steel castings
____________________________
in all high-stress areas
Operator’s Cab Pivots ____________________________ sealed with double side centering with
1 single floating pin per side, all bearings
Design resiliently mounted, sound insulated, large
____________________________ with wear resistant, steel bushings, bolts
windows for all-around visibility, integrated hardened and chromium-plated
falling object protection FOPS Hydraulic cylinders __________ Liebherr design, all cylinders located in well
Operator’s seat ________________ suspended, body-contoured with shock protected areas
absorber, adjustable to operator’s weight Hydraulic connections ______ pipes and hoses equipped with SAE split
Cabin windows ________________ 20,5 mm/0.8 in tinted armored glass for flange connections
front window and left hand side windows, Kinematics ______________________ Liebherr parallel face shovel attachment
all other windows in tinted safety glass, geometry
high pressure windshieldwasher-system
with 75 l/20 gal watertank, sun louvers on
all windows in heavy duty design
Heating system/ High Voltage Cable (as option)
Air conditioning ________________ heavy duty, high output air conditioner and
heater unit Flexible medium-voltage
Cabin pressurization ________ ventilation unit with filters cables ____________________________ are to be selected in accordance with the
Controls __________________________ joystick levers integrated into armrest of application for trailing operation, particu-
seat larly suitable for applications in which
Monitoring ______________________ via gauge and display abrasion and extremely high mechanical
Automatic engine shut off __ in case of winding and bearing overheating stresses are to be expected
Safety functions ______________ additional gauges with constant display for: Approvals/standards ________ • DIN VDE 0250, Part 813
engine load factor, hourmeter, hydraulic oil (VDE = Association of German Electrical
temperature Engineers)
• MSHA P-189-4
(= Mine Safety and Health Administration/
Harrisburg, USA)
Undercarriage • WUG/GE-83/98
(= Approval of the Polish Mining Inspec-
Construction ____________________ the construction of the undercarriage is the torate, necessary for use of cables in
same as on the diesel version Polish mines)
High voltage supply Cable capacity ________________ 300 m trailing cable
cable ______________________________ the high voltage supply cable enters at the Cable sizes ______________________ dependent on voltage, current and cable
rear of the undercarriage in a contact box, length
protection classification IP 67, a sealed slip Current-carrying capacity __ according to DIN VDE 0298, Part 4
ring connection with 4 power rings and
brushholders, protection classification
IP 67, between under- and uppercarriage
feeds the high voltage section
Design ____________________________ 3-piece undercarriage,
box type structures for center piece and
side frames, stress relieved
Hydraulic motor ________________ 2 axial piston motors per side frame
Travel gear ______________________ Liebherr reduction gear
Travel speed ____________________ 0 – 2,2 km/h / 0 – 1.4 mph
Parking brake __________________ spring engaged, hydraulically released wet
multi-disc brakes for each travel motor,
maintenance-free
Track components ____________ D12, maintenance-free forged double
ground pad
Track rollers/
Carrier rollers __________________ 9/2
Automatic track tensioner __ pressurized hydraulic cylinder with accu-
mulator
Transport ________________________ undercarriage side frames are removable

4 R 9350 Electric
Dimensions
A2
E A1
F D A

W1 W
C
H1 H2
H

K P
Q

L N
U S
Z B
V G
X

mm/ft in mm/ft in
A 6390/21’ ” P 2360/ 7’ 9”
A1 6490/21’ 4” Q 982/ 3’ 1”
A2 7190/23’ 7” S 5000/16’ 5”
C 7570/24’10” U 8334/27’ 1”
D 6360/20’10” Z 10470/34’ 4”
E 6525/21’ 5” N 850/ 2’ 9”
F 3100/10’ 2” B 6080/19’11”
H 5435/17’10” G 6340/20’10”
H1 6455/21’ 2” V 11800/38’ 9”
H2 6725/22’ 1” W 8100/26’ 7”
K 2235/ 7’ 4” W1 8700/28’ 7”
L 6400/20’11” X 18450/60’ 6”

A2
E A1
F D A

C
W1 H1 H2
H

K P
Q

L N
U S
Z B
V1 G
X1

mm/ft in mm/ft in
A 6390/21’ ” P 2360/ 7’ 9”
A1 6490/21’ 4” Q 982/ 3’ 1”
A2 7190/23’ 7” S 5000/16’ 5”
C 7570/24’10” U 8334/27’ 1”
D 6360/20’10” Z 10470/34’ 4”
E 6525/21’ 5” N 850/ 2’ 9”
F 3100/10’ 2” B 6080/19’11”
H 5435/17’10” G 6340/20’10”
H1 6455/21’ 2” V1 15900/52’20”
H2 6725/22’ 1” W1 7100/23’ 4”
K 2235/ 7’ 4” X1 20700/67’11”
L 6400/20’11”

R 9350 Electric 5
Backhoe Attachment
with Gooseneck Boom 9,30 m/30’6” and Stick 4,20 m/13’8”
ft m

60
Digging Envelope
-18
Max. reach at ground level 16,30 m/53’6”
-16 Max. teeth height 15,40 m/50’6”
50
Max. dump height 10,20 m/33’6”
-14
Max. digging depth 9,50 m/31’2”
40 -12
Max. digging force 880 kN ( 89,7 t)/197,750 lb
-10 Max. breakout force 1020 kN (104,0 t)/229,280 lb
30
-8

20 -6
Operating Weight
-4 and Ground Pressure
10
-2 The operating weight includes the basic machine with backhoe
attachment and a 18,00 m3/23.5 yd3 bucket.
0 0
Pad width mm/in 850/34
-2 Weight kg/lb 314600/693,600
-10 Ground pressure kg/cm2/PSI 2,61/37.12
-4

-20 -6

-8
-30
-10
18 16 14 12 10 8 6 4 2 0 m

60 50 40 30 20 10 0 ft

Bucket
Cutting width SAE mm/in 3400/1341) 3400/1341) 3400/1341)
Capacity SAE heaped m3/yd3 15,30/20 17,00/22.2 18,00/23.5
Weight kg/lb 17000/37,480 17790/39,220 18155/40,020
Suitable for material up to a specific weight of t/m3/lb/yd3 2,10/3,570 1,90/3,230 1,80/3,000
Wear kit level II II II
Bucket with delta cutting edge and tooth system Posilok size S 95.
1)

Wear kit level II: For heavy rock, not deteriorated or cracked. Has to be shot to be dug.
Additional buckets on request.

6 R 9350 Electric
Shovel Attachment
with Shovel Boom 6,75 m/22’2” and Stick 4,20 m/13’8”
ft m
Digging Envelope
60 18
Max. reach at ground level 13,75 m/45’1”
Max. dump height 11,20 m/36’9”

Seite ist rechts 2 mm schmäler


16
50 Max. crowd length 5,20 m/17’1”
Bucket opening width T 2500 mm/98”
14

Crowd force at ground level 1040 kN (106,0 t)/233,690 lb


40 12 Max. crowd force 1300 kN (132,5 t)/292,110 lb
T Max. breakout force 1060 kN (108,0 t)/238,100 lb
10
30
8

20 6
Operating Weight
and Ground Pressure
4
10 The operating weight includes the basic machine with shovel attach-
ment and a 18,00 m3/23.5 yd3 bucket.
2
Pad width mm/in 850/34
0 0 Weight kg/lb 322500/712,000
Ground pressure kg/cm2/PSI 2,68/38.12
-2
-10
-4
14 12 10 8 6 4 2 0m

50 40 30 20 10 0 ft

Bottom Dump Bucket


Cutting width SAE mm/in 4100/1611) 4100/1611) 4100/1611)
Capacity SAE heaped m3/yd3 15,30/20 17,00/22.2 18,00/23.5
Weight kg/lb 30000/66,140 31000/68,340 31500/69,450
Suitable for material up to a specific weight of t/m3/lb/yd3 2,10/3,570 1,90/3,230 1,80/3,000
Wear kit level II II II
Bottom dump bucket with delta cutting edge and tooth system Posilok size S 95.
1)

Wear kit level II: For heavy rock, not deteriorated or cracked. Has to be shot to be dug.
Additional bottom dump buckets on request.

R 9350 Electric 7
Component Dimensions and Weights
L

Seite ist rechts 15 mm schmäler (Klappseite)


Cab
H L Length mm/ft in 3215/10’6”
H Height mm/ft in 2885/ 9’6”
Width mm/ft in 1900/ 6’3”
Weight kg/lb 2800/6,170

Cab Elevation (with grease container and


electrical box)
L Length mm/ft in 2415/7’11”
H H Height mm/ft in 2550/8’ 4”
Width mm/ft in 2500/8’ 2”
Weight kg/lb 4200/9,260

L
Electric Box High Voltage
(with substructure switch box)
L Length mm/ft in 3000/9’8”
H
H Height mm/ft in 2900/9’5”
Width mm/ft in 2200/7’2”
Weight kg/lb 7200/15,870

B1

Powerpack (with Electric Box Low Voltage)


L Length mm/ft in 4800/15’9”
H1 H2
H1 Height mm/ft in 3000/ 9’8”
L H2 Height mm/ft in 3400/11’1”
B1 Width mm/ft in 2200/ 7’2”
L Weight kg/lb 17500/36,600

Rotation Deck (with swing ring, swing gears,


control valve bracket and service flap)
H L Length mm/ft in 8100/26’7”
H Height mm/ft in 3882/12’8”
Width mm/ft in 3700/12’2”
Weight kg/lb 46900/103,400

Counterweight
H
L Length mm/ft in 1100/ 3’7”
H Height mm/ft in 3250/10’8”
Width mm/ft in 6000/19’8”
Weight kg/lb 25320/55,820

Hydraulik Tank with Fans


H L Length mm/ft in 4920/16’2”
H Height mm/ft in 2900/ 9’6”
Width mm/ft in 1820/ 6’ ”
Weight kg/lb 7800/17,200

Hydraulic Oil
Weight kg/lb 4450/9,810

8 R 9350 Electric
Component Dimensions and Weights
L Small Pieces

Seite ist rechts 15 mm schmäler (Klappseite)


L Length mm/ft in 4500/14’9”
H Height mm/ft in 2600/ 8’6”
H
Width mm/ft in 2000/ 6’7”
Weight kg/lb 4500/9,920

Catwalk Box Left


H L Length mm/ft in 2140/7’ ”
H Height mm/ft in 2960/9’9”
Width mm/ft in 700/2’4”
Weight kg/lb 1900/4,190

H Catwalk Box Right


L Length mm/ft in 2180/7’2”
H Height mm/ft in 2960/9’9”
Width mm/ft in 950/3’1”
L Weight kg/lb 1600/3,530

Side Frame (two)


L
L Length mm/ft in 8334/27’ 4”
H Height mm/ft in 2360/ 7’ 9”
Width over
travel drive mm/ft in 2055/ 6’ 9”
H Width without
travel drive mm/ft in 1485/ 4’10”
Weight kg/lb 2 x 45400/2 x 100,100

H
Undercarriage Central Girder
L Length mm/ft in 3670/12’ ”
H Height mm/ft in 2482/ 8’2”
Width mm/ft in 3670/ 8’9”
L Weight kg/lb 27800/61,300

Shovel Boom
H L Length mm/ft in 7250/23’ 9”
H Height mm/ft in 2350/ 7’ 9”
Width mm/ft in 2400/ 7’10”
Weight kg/lb 25200/55,560

Hoist Cylinder (two)


L
for Shovel Attachment
L Length mm/ft in 4690/15’ 5”
Ø Diameter mm/in 550/ ’22”
Weight kg/lb 2 x 3510/2 x 7,700

H Shovel Stick
L Length mm/ft in 4700/15’5”
H Height mm/ft in 1900/ 6’3”
Width mm/ft in 2250/ 7’5”
L Weight kg/lb 12750/28,110

R 9350 Electric 9
Component Dimensions and Weights
L
Crowd Cylinder (two)
L Length mm/ft in 3350/11’’
Ø Diameter mm/in 400/15”
Weight kg/lb 2 x 1470/2 x 3,240

Seite ist rechts 2 mm schmäler


Bottom Dump 15,30 m3/ 17,00 m3/ 18,00 m3/
H Bucket 20.0 yd3 22.2 yd3 23.5 yd3
L Length mm/ft in 3700/12’2” 3900/12’10” 4200/13’9”
H Height mm/ft in 3800/12’6” 3800/12’ 6” 3800/12’6”
Width mm/ft in 4200/13’9” 4200/13’ 9” 4200/13’9”
L Weight kg/lb 30000/66,000 31000/68,340 31500/69,450

RG-BK-RP LFR/SP 10215820-0-08.06 Illustrations and data may differ from standard equipment. Subject to change without notice. All indicated loads are based in accordance with ISO 9248.
L
Bucket Tilt Cylinder (two)
L Length mm/ft in 3950/13’’
Ø Diameter mm/in 450/18”
Weight kg/lb 2 x 2015/2 x 4,440

L
Gooseneck Boom
with Stick Cylinders
H L Length mm/ft in 9800/32’ 2”
H Height mm/ft in 3900/12’10”
Width mm/ft in 2200/ 7’ 3”
Weight kg/lb 30700/67,682

Hoist Cylinders (two)


L
for Backhoe Attachment
L Length mm/ft in 4680/15’ 4”
Ø Diameter mm/in 550/ ’22”
Weight kg/lb 2 x 3800/2 x 8,380

Stick with Bucket Cylinders


H L Length mm/ft in 6000/19’ 8”
H Height mm/ft in 2400/ 7’10”
Width mm/ft in 1750/ 5’ 9”
Weight kg/lb 18940/41,670

H
Backhoe Bucket 15,30 m3/ 17,00 m3/ 18,0 m3/
20.0 yd3 22.2 yd3 23.5 yd3
L Length mm/ft in 4000/13’ 1” 4000/13’1” 4200/13’9”
H Height mm/ft in 2700/ 8’10” 2800/ 9’2” 2800/ 9’2”
Width mm/ft in 3500/11’ 6” 3500/11’6” 3500/11’6”
L Weight kg/lb 17000/37,480 17790/39,220 18155/40,020

Liebherr-France SAS
2, avenue Joseph Rey, B.P. 90287, F-68005 Colmar Cedex
콯 +33 389 21 30 30, Fax +33 389 21 37 93
www.liebherr.com, E-Mail: info.lfr@liebherr.com

Anda mungkin juga menyukai