Anda di halaman 1dari 47

Single Packaged

Roof Top Air Conditioners


PY Series
PY036 - PY360
3 TR thru 30 TR
10 kW thru 105 kW

The "Comfort" Series

Company Business
Zamil Air Conditioners was founded in 1974 as one of the first air conditioning business to be established in Saudi Arabia
and today is a leading international manufacturer of air conditioning systems and is No. 1 in the Middle East.
Zamil Air conditioners manufactures both consumer and central air conditioners and has sales operations in over 55
countries in the Middle East, Europe, Africa and Asia.
The companys operations are structured into four Strategic Business Units (SBUs) supporting five in-house product and
service brands as well as a number of international brands under the OEM sales.
The five in-house brands are Classic, Cooline, CoolCare, Clima Tech and Geoclima.
The four SBUs are:
1. Consumer Business Unit supporting Classic, Cooline, GE and OEM brands for consumers.
2. Unitary & Applied Business Unit supporting Classic, Cooline, GE and OEM brands for commercial and industrial
customers.
3. Zamil CoolCare providing engineering & project management services, HVAC maintenance, retrofit services and parts.
4. Geoclima srl is an independent business supporting other SBUs for their requirement of Chillers & Double skin AHUs.
The first three SBUs - Consumer Products, Unitary & Applied Products and CoolCare Service direct their business
operations from the corporate headquarters at Dammam, Saudi Arabia.
Geoclima has its engineering & production departments located at Monfalcone, Italy and has a design center in Austria.
All the four SBUs, while operating independently, supplement each others activities in a way that makes synergy work at
its best and achieve the corporate goals of maximizing customer satisfaction.
Factories and Productions
Zamil Air Conditioners has two manufacturing plants in Dammam, Saudi Arabia and has one speciality production facility
in Italy operated by Geoclima.
The company can produce up to 550,000 Room Air Conditioners, 300,000 Mini-Split systems and 50,000 Central Air
Conditioning systems per year.
Quality & Product Certificates
The Quality systems and policies at Zamil Air Conditioners comply with the required ISO 9001:2000 certification.
Zamil Air Conditioners is the first company in Saudi Arabia to receive the SASO (Saudi Arabias Standard Organization)
Certificate for Room Air Conditioners. ZAC's products are also certified with:
1. CE (Council of European Community)
2. UL (Underwriters Laboratory)
3. Eurovent
4. ASME
5. ETL
Other awards include the prestigious Engineering Excellence Award of General Electric and the inaugural Prince Mohammed
bin Fahd Al Saud Award for Factory Safety.
Our Products
In addition to the consumer products such as the Room Air Conditioners (RAC) and the Mini Splits, Zamil Air Conditioners
manufacturers a host of residential, commercial and industrial air conditioners. This broad range extends from the Concealed Units up to 5 tons, the Ducted Splits up to 30 tons, the Packaged Units up to 90 tons, the Single and Double Skin
Air Handling Units up to 70,630 CFM and the Water Chillers up to 660 tons cooling capacity.

INDEX
Contents

Page

Model decoding ........................................................................................................................................ 3


Blower drive options ................................................................................................................................. 4
Standard specifications/options/accessories ......................................................................................... 5-7
Physical data ......................................................................................................................................... 8-9
Selection procedure ............................................................................................................................... 10
Cooling capacities ............................................................................................................................. 11-15
Electrical data .................................................................................................................................... 16-22
Fan performance data ....................................................................................................................... 23-28
Sound level data ................................................................................................................................ 29-34
Pressure drop/blower motor efficiency ................................................................................................... 35
Unit dimensions ................................................................................................................................. 36-38
Controls and sequence of operation ....................................................................................................... 39
Typical schematic wiring diagram ...................................................................................................... 40-41
Parts list ............................................................................................................................................ 42-44

CONTINUING RESEARCH RESULTS IN STEADY IMPROVEMENTS.


THEREFORE, THESE SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
1

Features
General
Enjoy the "Comfort" series by "Zamil Air Conditioners"
The "Comfort" series of Packaged units (PY) is another perfect illustration of how "Zamil Air Conditioners" can simplify the air conditioning business for Clients, Consultants and Contractors. It is a clear
statement for all that your life will be more "Comfortable" when you
use the (PY) series.

Some of the Salient Features


Quality/Reliability:
Using proven reliable components, the (PY) "Comfort" series is designed, assembled and produced to meet the highest quality standards. It will operate to the satisfaction of the End User years after
years. That translates into peace of mind and sustained "Comfort".
Simple Selection/Design Integration:
The (PY) series is conceived to be easily fitted into the system design. Its compact dimensions and optimized air flow performance will
provide the designer with an added "Comfort" in the process of selecting and integrating the units in the overall design.
Simple Installation/Maintenance:
Connect the Power cables and the Control wiring (all located in one
area), connect ducting using the built-in duct flanges, arrange for
proper drainage, reach in for any part/component through wide ample
service/access doors...Installation and Maintenance cannot be more
"Comfortable".
Ease of Operation:
Let the digital "Performex-1TM" controller do
all the thinking! Just set the desired temperature level and the "Performex-1TM" controller
will take care of all the operating functions
while monitoring any abnormal signal to prevent/protect the unit and its components from
any damage...and ensuring the complete
"Comfort" for the occupants.

And on top of that, the (PY) "Comfort" series comes with a host of
useful features such as the different types of corrosion protection
TM
solutions for the coils, Fresh Air Damper and UV Flow for added
IAQ and "Comfort".
2

F : 460-3-60

M : 380-3-60
(4 WIRE)

H : 208/230-3-60

C : 208/230-1-60*

6
ELECTRICAL
SUPPLY
( V-Ph-Hz )

8
DRIVE
OPTIONS

9
HEATER OPTIONS
(kW/STAGE)

W : 0.75 HP ODP
(DIRECT DRIVE)
D : 10 /2**

C : 7.5 /1

U : 0.5 HP ODP N : DIRECT N : NO HEATER


DRIVE
(DIRECT DRIVE)
A : 5/1

7
BLOWER
MOTOR

L : COPPER FIN
M : ALUMINUM
FINS WITH TG.
N : COPPER FINS
WITH TG.

L : COPPER FIN
M : ALUMINUM
FINS WITH TG.
N : COPPER FINS
WITH TG.

K : COATED
K : COATED
ALUMINUM FIN
ALUMINUM FIN

N : STANDARD UNIT

12
ACCESSORIES

E : 3 HP ODP
G : 5 HP ODP
G : 5 HP ODP
J : 7.5 HP ODP
J : 7.5 HP ODP
J : 7.5 HP ODP
L : 10 HP ODP
L : 10 HP ODP
M : 15 HP ODP

150

180
210

240

300
340

360

Z : 2 HP ODP
E : 3 HP ODP

K : ALT. II

J : ALT. I

R : 1.5 HP ODP
Z : 2 HP ODP

E : 3 HP ODP

F : 460-3-60

M : 380-3-60
(4 WIRE)

H : 208/230-3-60

8
DRIVE
OPTIONS

7
BLOWER
MOTOR

120

090
100

075

3, 4 & 5
6
NOMINAL ELECTRICAL
COOLING
SUPPLY
CAPACITY
( V-Ph-Hz )
(MBH)

L : 40/2 (For PY240 - 360)

K : 35/2

J : 30/2

H : 25/2

G : 20/2

F : 15/2

N : NO HEATER

H : 25/2 (For PY090 - 150)

G : 20/2 (For PY090 - 150)

F : 15/2

E : 12/2

D : 10/2

C : 7.5/1

B : 6/1

N : NO HEATER

9
HEATER OPTIONS
(kW/STAGE)
11
CONDENSER
COIL

12
PDS OPTION

N : COPPER FINS
WITH TG.

M : ALUMINUM
FINS WITH TG.

L : COPPER FIN

N : COPPER FINS
WITH TG.

M : ALUMINUM
FINS WITH TG.

L : COPPER FIN

P : STD. UNIT
K : COATED
K : COATED
WITH PDS
ALUMINUM FIN
ALUMINUM FIN

J : ALUMINUM FIN J : ALUMINUM FIN N : NO PDS

10
EVAPORATOR
COIL

A
B
C
D
E
F
G
H
J
L
M

:
:
:
:
:
:
:
:
:
:
:

F
G
H
J
L
M

:
:
:
:
:
:

I, V & K
U, V & K
I, U, V & K
I&K
V&K
U&K

C : U&V
D : I, U & V
E : I, U & K

K : ADJ.
PRESSURE
SWITCH
A : I&U
B : I&V

V : VOLT FREE
CONTACTS*

U : UVM

N : STD. UNIT
I : ANTI-ICE

B : ECONOMIZER
WITH ENTHALPY
SENSOR

A : ECONOMIZER

C : STD. UNIT WITH


FRESH AIR HOOD
& MANUAL
DAMPER

N : STANDARD UNIT

16
THERMOSTAT
OPTION

D : UNIT WITHOUT
THERMOSTAT

S : UNIT WITH
THERMOSTAT

15
THERMOSTAT
OPTION

D : UNIT
B : 2" THICK
ALUMINUM
WITHOUT
THERMOSTAT

S : UNIT WITH
A : 1" THICK
ALUMINUM
THERMOSTAT

15
FILTER
OPTIONS

A : 1" THICK
ALUMINUM

14
FILTER OPTIONS

14
ACCESSORIES

I&U
I&V
U&V
I, U & V
I, U & K
I, V & K
U, V & K
I, U, V & K
I&K
V&K
U&K

K : ADJ. PRESSURE
SWITCH

V : VOLT FREE
CONTACTS***

N : STD. UNIT
I : ANTI-ICE
U : UVM

13
ELECTRICAL
OPTIONS

13
ELECTRICAL
OPTIONS

NOTE: * Volt free contact option is available as: A) Unit ON/TRIP indication, B) Compressor RUN/TRIP indication, C) Blower motor RUN/TRIP indication.

PACKAGED
UNIT

PY

1&2
BASIC

11
CONDENSER
COIL

J : ALUMINUM FIN J : ALUMINUM FIN

10
EVAPORATOR
COIL

MODEL DECODING

Applicable for PY036 & PY048 models only.


Applicable for PY060 models only.
Volt free contact option is available as: A) Unit ON/TRIP indication, B) Compressor RUN/TRIP indication, C) Blower motor RUN/TRIP indication.

048
060

036

3, 4 & 5
NOMINAL
COOLING
CAPACITY
(MBH)

MODELS: PY075 - PY360 (BELT DRIVEN MOTOR)

*
**
***

NOTE:

PACKAGED
UNIT

PY

1&2
BASIC

MODELS: PY036 - PY060 (DIRECT DRIVE MOTOR)

BLOWER DRIVE OPTIONS


MOTOR
MODEL
NUMBER

OPTION

PY075
PY090
PY100
PY120
PY150
PY180
PY210
PY240
PY300
PY340
PY360

ALT. I
ALT. II
ALT. I
ALT. II
ALT. I
ALT. II
ALT. I
ALT. II
ALT. I
ALT. II

BLOWER

APPROX. SPEED
CHANGE PER
PULLEY TURN
(RPM)

HP

RPM

1.5
2
2
3
2
3

1750
1750
1750
1750
1750
1750
1750
1750
1750
1750

PULLEY
PITCH DIA.
(INCH)
2.7 - 3.7
2.7 - 3.7
2.7 - 3.7
2.7 - 3.7
2.7 - 3.7
3.1 - 4.1
3.1 - 4.1
3.1 - 4.1
3.7 - 4.7
4.8 - 6.0

1750

3.7 - 4.7

719

914

32

1750

4.3 - 5.5

875

1119

8.6

41

SPEED RANGE (RPM)


MINIMUM

MAXIMUM

844
1027
844
1152
716
969
733
889
819
944

1156
1407
1156
1579
981
1281
970
1176
1041
1180

PULLEY
PITCH DIA.
(INCH)
5.6
4.6
5.6
4.1
6.6
5.6
7.4
6.1
7.9
8.9

52
63
52
71
44
52
40
48
37
39

ALT. II

3
5
5
7.5

ALT. I

1750

3.7 - 4.7

752

956

8.6

34

ALT. II

7.5

1750

4.3 - 5.5

875

1119

8.6

41

1750

4.3 - 5.5

684

875

11

32

1750

4.3 - 5.5

875

1119

8.6

41

1750

4.3 - 5.5

684

875

11

32

1750

4.3 - 5.5

875

1119

8.6

41

1750

4.3 - 5.5

684

875

11

32

1750

4.3 - 5.5

875

1119

8.6

41

1750
1750

4.3 - 5.5
5.5 - 6.9

684
875

875
1098

11
11

32
37

ALT. I

ALT. I
ALT. II
ALT. I
ALT. II
ALT. I
ALT. II
ALT. I
ALT. II

7.5
7.5/10
7.5/10
10
15

STANDARD SPECIFICATIONS
A. General
Packaged cooling or combination heating and cooling units suitable for mounting on the roof or ground. The packaged
unit consists of reciprocating compressors, cooling coil, condenser coil, control wiring and interconnecting piping - all
factory assembled and mounted on heavy gauge G-90 galvanized steel sheet press formed base, ready for field connection to utilities and ducts. The packaged unit is of rigid construction with holes provided in the base rails for overhead
rigging. The unit is provided with an integral weather resistant control panel.
These units are rated and tested in accordance with ARI standard 210/ ARI 360.

B. Unit Enclosure
Panels are of heavy gauge, G-90 galvanized steel sheet with removable access panels, completely weatherized for
outdoor installation and properly reinforced and brazed. Panels and access doors are provided for inspection and access
for all internal parts. Enclosures are provided with adequately reinforced points of support for setting the unit. Steel sheet
panels are zinc-coated and galvanized by the hot dip process of lock forming quality conforming to ASTM A 653 commercial weight G-90, followed by baked on electrostatic polyester dry powder coat paint, on all external panels.

C. Compressor
Compressors are hermetic reciprocating for PY036 - PY060 & PY090 - PY120 and hermetic scroll for all other models.
They are provided with all the standard controls and accessories necessary for safe operation. These are equipped with
internal motor protector, factory installed crank case heater and rubber vibration isolator for quiet and efficient operation.

D. Air Cooled Condensing Section


1. The air-cooled condensing section is enclosed within the unit housing and consists of condenser coil, fan(s), electric
motor(s) and inherently protected compressor(s). Inner grooved copper tubes with wall thickness of 0.0175 inches
(0.445 mm), mechanically bonded to enhanced aluminum fins are standard for all condenser coils. Return bends have
0.022 inch thickness (0.56 mm). As an option, corrugated copper fins or enhanced coated aluminum fins may
be provided. Tube support sheets are galvanized steel, formed to provide structural strength.
2. Fans are propeller type, direct driven, upward discharge and provided with fan grille mounted on the casing.
3. Motors are totally enclosed air-over type with class F insulation. Inherent thermal protection is automatic reset type.
4

E. Evaporator Coil Section


1. All cooling coils are of enhanced louvered fins and inner grooved copper tubes with wall thickness of 0.0175 inches
(0.445mm), mechanically bonded to aluminum fins. Return bend has 0.022 inch thickness (0.56 mm). As option,
enhanced coated aluminum fins or corrugated copper fins may be provided. Tube support sheets are galvanized steel, formed to provide structural strength.
2. Drain Pan: An insulated drain Pan made of G-90 galvanized steel is provided.
3. Insulation: Insulation is supplied in adequate density and thickness for all units to prevent condensation from forming
on the unit casing. Insulation meets the requirements of NFPA 90A and is protected against deterioration and erosion
from air currents.

F. Evaporator Fan
PY036 - PY060: Evaporator fan is of a centrifugal forward-curved blade design and sized to meet system airflow/
pressure using direct drive motors. These fans are statically / dynamically balanced in the fan housing during final
assembly. Fan motors have ball bearings and conform to NEMA MG-1 & MG-2. Motor starters are magnetic contactor,
across-the-line type.
PY075 - PY360: Evaporator fan is of centrifugal forward-curved blade design capable of handling total required CFM and
static pressure in the low and the medium ranges. Casings are made of galvanized steel. Blower motors are of the open
drip proof type (totally enclosed types are optional) and conform to NEMA MG-1 and MG-2. Fan drive is through
adjustable pitch pulleys and belt driven. Blower motor is mounted on adjustable base and secured by locking device. Fan
wheels shafts and bearing are selected to operate at 25% below first critical speed. Pillow block bearings are selected for
at 200,000 hours average life at design operating conditions. Shaft is turned, ground and polished from solid steel. Fans
and pulleys are keyed to shaft and designed for continuous operation at maximum motor horse power and fan speed. All
rotating components and assemblies are statically and dynamically balanced and every unit is vibration tested before
shipment from the factory.

G. Microprocessor Controller
These Packaged units are provided with a microprocessor control board incorporating the following features:

BALANCE LOADING OF COMPRESSORS: The units electronic control automatically operates lead/lag sequence
of compressors. This is to load the compressors evenly over long periods of operation. If required however, compressor-1 can also be set to always lead. In this case, compressor-1 always starts first and stops last. (Selectable through
dip switch setting on control board).
PUMP DOWN FUNCTION: In units equipped with pump down system, the controller provides the time delay between
solenoids opening and compressor starting to equalize the pressure in the system necessary for compressor to startup. (Selectable through dip switch setting on control board).
COMPRESSOR ANTI-RECYCLING PROTECTION: The controller has a built-in 3 minutes minimum off timer for
compressor. This is for compressor protection in case of accidental manual re-set or immediate re-cycling of thermostat due to load demand.
COMPRESSOR LOCK-OUT FUNCTION: If any of the units safety control trips due to abnormal conditions, the
electronic controls locks out the compressor after a pre-determined timing preventing a re-start unless attended by a
qualified service technician. The unit can be re-started through thermostat re-set after ensuring safe system conditions.
FAULT DIAGNOSTICS: In case of system fault, LEDs on the board emits a flashing signal indicating where the fault
is. This is to guide the service technician in identifying the fault.
DIGITAL I/Os: The units control board is compatible to operate with a DDC controller or any standard 24V a.c.
thermostat commercially available.
SEQUENTIAL CONTROL: With input signals from the thermostat, the motors in the equipment is started in sequential order: supply fan condenser fan compressor; at a pre-determined timings.

OPTIONS AND ACCESSORIES


A. Electric Heaters
Electric heaters are of the resistance open coil type and conform to UL requirements. Electrical characteristics, kW capacities
and number of stages are as indicated. Airflow switches, fusible links and overheat limit thermostats are provided to shut-off
power in case of airflow failure/overheat. Electric heater kit is installed as an externally mounted kit at the supply opening.

B. UV FlowTM Light Emitters:


The damp & dark environment inside the unit could contribute for the growth and development of hazardous bacteria and fungi.
TM
The UV flow concept uses emitter of Ultra Violet to simulate the effect of healthy sun radiation. This will inhibit the growth of
TM
these microorganism reducing in this manner mold related allergies and diseases. Breath safely with UV flow .
TM

To order UV flow use the kit number in tables below:

MODEL No. PY036/048/060


KIT PART No.

700-391-30

PY075

PY090

PY100

PY120/150

PY180/210

PY240/300/340

PY360

700-391-23

700-391-24

700-391-25

700-391-26

700-391-27

700-391-28

700-391-31

C. Economizer
This can be provided as an option to be ordered separately if required for horizontal discharge units only. Economizer
utilizes cool outside air to satisfy cooling load to minimize energy consumption by maintaining poise between outside air
intake and compressor operation when required as per load demand.
The Economizer is operative either by a dry bulb Outdoor Air Thermostat (OAT) or a Solid State Enthalpy Controller (EC)
to sense the outdoor air temperature. The unit is equipped with an electronic control board, the PsychroTroll with a
sensitive feedback system carefully modulating the damper to allow correct percentage of fresh air and return air. The
PsychroTroll is designed to match with a separate Zamil electronic controller & thermostat.

D. Electronic Thermostat
General information: Electronic thermostat shall control one or two stage heating and cooling applications. The thermostat normally displays room temperature and mode of operation.
The temperature can be set by up/down buttons for both cooling and heating cycles. The thermostat also allows you to
select continuous fan operation, or have the fan on intermittent operation with the equipment.
The thermostat is best located about 1500 mm (5 Ft.) above floor level, on a partition wall (not an outside wall), and should
not be exposed to direct light from lamps, sun etc. It should be in return air stream, away from supply air registers/diffusers.

Single/dual stage - Cooling & heating.


Low voltage control - 24 VAC (nominal).
Room temperature display - in C or F.
Mode of operation - FAN/COOL/HEAT/AUTO.
Fan mode - ON: Continuous fan operation; AUTO: Fan operates ON/OFF with compressor.
Heating & cooling setpoint is permissible.
Temperature set button - Up for increasing & down for decreasing temperature.
Built-in compressor fault & clogged filter indication led lights.
Remote sensing function as an option. Duct sensor is provided with the thermostat.
0

TYPICAL THERMOSTAT
Part No.
800-652-61

Heating Cooling Selector Switch Positions


Stages Stages Mode Switch Fan Switch
1&2

1&2

OFF-HEAT/COOL

ON - AUTO

E. Under Voltage Monitors (UVM)


UVM combines voltage monitoring, phase loss, reversal and imbalance. When the voltage drops below safe limits, the
control relays turn off the equipment. When the device sensed such faults, it will cut-off the supply in the control circuit
thereby cutting off power to the motors. The voltage monitor will re-set automatically when power is brought back to its
normal conditions.
LINE VOLTAGE
RANGE
190 - 480 VAC

TRIP & RE-SET VOLTAGE (% OF SET POINT)


UNDER VOLTAGE

OVER VOLTAGE

PHASE IMBALANCE

TRIP

RE-SET

TRIP

RE-SET

TRIP

RE-SET

90%

93%

110%

107%

6%

4.5%

STANDARD FEATURES/OPTIONS/ACCESSORIES
STANDARD
FEATURES

DESCRIPTION
Horizontal discharge
Compressor crankcase heaters
Evaporator fanbelt driven(1)
Evaporator fan motor ODP type (TEFC type optional)(2)
Condenser fan direct drive, propeller type
Condenser fan motor totally enclosed air-over type
Electric heaters
Filter drier
Filter, synthetic media
Filter, aluminum
Compressor overload protection
Low pressure switch
High pressure switch
Cooling & heating thermostat
Condenser fan guard
Condenser coil guard
Manual outside air damper(3)
Economizer
Enthalpy sensor
NOTES:
(1) Direct drive motors for PY036 to PY060.
(2) TEFC motors are available for PY075 to PY360.
(3) Manual outside air damper is available for PY075 to PY360.

OPTION
(FACTORY
INSTALLED)

ACCESSORY
(FIELD
INSTALLED)

PHYSICAL DATA
(DIRECT DRIVE MOTOR)
MODEL NUMBER

PY036

PY048

PY060

NOMINAL CAPACITY, TONS (kW)

3 (10.5)

4 (14)

5 (17.6)

Quantity

Oil (oz)

45

45

70

COMPRESSOR

Refrigerant

R-22

Operating Charge (oz)


CONDENSER FAN

91

Type/Drive

Nominal CFM (L/S)


Motor HP RPM

EVAPORATOR BLOWER

1 24

1 24

1 24

3200 (1510)

3000 (1415)

3000 (1415)

1/3 1075

1/3 1075

1/3 1075

Inner Grooved Tubes and Enhanced Fins

Type
Tube dia. - Rows - Fins per inch

3/8-1-16

3/8-2-16

3/8-2-16

Total face area, Sq. ft. (Sq. m.)

10.8 (1)

10.8 (1)

10.8 (1)

Type

Centrifugal

Size (inch)

10 x 8

10 x 8

Drive type

Motor HP (Standard)

1200 (566)

1600 (755)

1800 (850)

0.5

0.75

0.75

Type

Inner Grooved Tubes and Enhanced Fins

Tube dia. - Rows - Fins per inch

3/8-3-14

Total face area, Sq. ft. (Sq. m.)

4.5 (0.42)

3/8-3-14

3/8-3-14

5.4 (0.5)

5.4 (0.5)

LOW PRESSURE
SWITCH

Open

25 5 PSIG

Close

50 5 PSIG

RETURN AIR FILTERS

Quantity
Size (inch)

SHIPPING WEIGHT

10 x 8

Direct Drive

Nominal CFM (L/S)

EVAPORATOR COIL

135

Propeller/Direct

Quantity Diameter (inch)

CONDENSER COIL

149

Kgs.

16 x 25

16 x 25

16 x 25

195

213

215

NOTE: Direct drive motors have single speed connection only. Factory set at medium speed.

PHYSICAL DATA
MODEL NUMBER

PY075 PY090 PY100 PY120 PY150 PY180 PY210 PY240 PY300 PY340 PY360

NOMINAL CAPACITY, TONS (kW)


COMPRESSOR

6 (21)

7.5 (26)

8.5 (30)

10 (35)

12 (42)

15 (53)

17.5 (62)

20 (71)

25 (88)

27 (95)

30 (105)

Quantity

Oil (oz)

60

45 x 2

45 x 2

70 x 2

60 x 2 60 & 81 110 x 2 110 x 2 110 x 2 140 x 2 140 x 2

Refrigerant
Operating Charge (oz)
CONDENSER FAN

R-22
144

111 x 2 120 x 2 122 x 2 165 x 2 180 & 212 259 x 2 288 x 2 368 x 2 371 x 2 462 x 2

Type/Drive

Propeller/Direct

Qty. Diameter (inch)

1 26

Nominal CFM (L/S)

4800(2265) 6000(2830)

Motor HP RPM

1/3 850

2 26
6600 (3115)

11500(5425) 11000(5190) 15700(7410)

3/4 1140

CONDENSER COIL Type


3/8-2-16

20 (1.86)

30 (2.78)

Type
12 x 12

15 x 15

Drive type

Factory setting full turns open


Fan pulley pitch dia.

1.5/2

2/3

2/3

56 / 56

3/5
56/184T

5/7.5

5/7.5

7.5

184T/213T

20 x 18

7.5/10

7.5/10

213T/215T

10/15
215T/254T

5.6

5.6

6.6

7.4

7.9

8.6

11

11

11

11

Inner Grooved Tubes and Enhanced Fins


3/8-3-14
6 (0.56)

9 (0.84)

3/8-2-14

Open

25 5 PSIG

Close

50 5 PSIG

RETURN AIR
FILTERS

Qty.

4
16-1/2 x 18-3/8
335

360

3/8-3-14

10 (0.93) 12.5 (1.16) 12.5 (1.16) 19.5 (1.81) 19.5 (1.81)

LOW PRESSURE
SWITCH

SHIPPING WEIGHT Kgs.

18 x 18

845-1405 845-1580 715-1280 730-1175 820-1180 719-1120 752-1120 685-1120 685-1120 685-1120 685-1098

Tube dia. - Rows - Fins per inch

Size (inch)

48 (4)

2400(1135) 3000(1415) 3400(1605) 4000(1890) 4800(2265) 6000(2830) 7000(3300) 7500(3540) 9600(4530) 10500(4955) 11250(5309)

EVAPORATOR COIL Type

Total face area, Sq. ft. (Sq. m.)

38 (3.53)

Belt

Motor Frame (NEMA) Std. / Alt.


Fan RPM range

3/8-3-14

Centrifugal

Size (inch)

Motor HP - Std. / Alt

15400(7268)

1.5 1140

3/8-3-16 3/8-2-14 3/8-3-14 3/8-2-14

Total face area, Sq. ft. (Sq. m.) 14 (1.3) 16 (1.5)

Nominal CFM (L/S)

15000(7080)

Inner Grooved Tubes and Enhanced Fins

Tube dia. - Rows - Fins per inch

EVAPORATOR
BLOWER

2 30

27 (2.5)

445

450

785

27 (2.5)

27 (2.5)

18 x 18 (1)
18 x 24 (3)
24 x 24 (2)

18 x 24
440

22 (2.04)

3/8-4-14

840

12 x 24 (2)
24 x 24 (6)

970

975

1030

1323

SELECTION PROCEDURE
1. Determine cooling and heating capacity requirements at design conditions
Data:
Condenser entering air temperature
Evaporator entering air temperature
Evaporator airflow
Required cooling capacity
Sensible heat capacity
Required heating capacity
External static pressure
Power supply (V-Ph-Hz)

: 950F
: 800F DB / 670F WB
: 7500 CFM
: 235,000 BTUH
: 160,000 BTUH
: 20 kW
: 1.23 INCH WG.
: 208/230-3-60

2. Unit selection based on required cooling capacity


Enter cooling capacity performance data at condenser entering air temp. at 950F and evaporator entering air temp. 800F
DB, 670F WB, 7500 CFM airflow. The PY240 unit will give 250,700 BTUH cooling capacity (gross) and 180,900 BTUH
sensible heat capacity (gross).

3. Electric heater selection


Heating capacity required =20 kW.
Enter electric heating table for PY240 at 208/230-3-60 power supply.
20 kW heater at 208/230 volts satisfies the required heating.

4. Determine fan speed and power requirements at design conditions


Before entering the fan performance tables, calculate the summation of external static pressure for the required components as follows.
External static pressure
Electric heater

: 1.23 INCH WG.


: 0.17 INCH WG.
1.4 INCH WG.

Enter fan performance table for PY240 model. For 7500 CFM and external static pressure of 1.4 INCH WG, it require 911 RPM
and 4.45 brake horse power (BHP) wherein the standard motor will meet job requirements.

5. Determine input power to motor


Use fan motor efficiency table.
BHP x 746 watts
Blower motor watts =
=
Motor efficiency

4.45 x 746
0.81

= 4098 watts.

6. Determine net capacities


Above capacities are gross and do not include blower motor heat gain.
Determine net capacities as follows:
Net cooling capacity
= Gross cooling capacity blower motor heat
= 250,700 (4098 WATTS x 3.413 BTUH/WATTS) = 236,714 BTUH
Net sensible capacity = 180,900 (4098 WATTS x 3.413 BTUH/WATTS) = 166,914 BTUH

7. Altitude correction factors for cooling capacity


ALTITUDE, FT.
FACTOR

2000

4000

6000

8000 10000

Total capacity

0.98

0.96

0.93

0.90

0.88

Sensible capacity

0.93

0.86

0.80

0.75

0.70

10

COOLING CAPACITIES
Model No.: PY036
CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

875/0.087
62
32.14
26.78
3.35
30.42
26.01
3.54
28.56
25.17
3.69
26.69
24.33
3.85
24.48
22.96
4.03

67
35.01
22.48
3.53
33.23
21.76
3.73
31.22
20.95
3.89
29.21
20.14
4.07
26.86
19.38
4.27

72
38.05
18.09
3.71
36.21
17.43
3.92
34.06
16.66
4.11
31.91
15.89
4.31
29.38
15.14
4.53

EVAPORATOR AIRFLOW, CFM/DR


1000/0.096
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
33.25
36.20
39.40
28.96
24.10
19.19
3.44
3.61
3.80
31.46
34.38
37.46
28.18
23.40
18.51
3.62
3.81
4.01
29.50
32.30
35.26
27.31
22.58
17.74
3.77
3.98
4.21
27.54
30.17
33.02
25.70
21.73
16.96
3.94
4.16
4.42
25.27
27.75
30.39
23.71
20.97
16.20
4.12
4.37
4.64

1175/0.107
62
34.41
31.83
3.55
32.56
30.54
3.73
30.51
28.56
3.89
28.52
26.61
4.05
26.11
24.50
4.25

67
37.54
26.27
3.72
35.61
25.54
3.93
33.42
24.69
4.10
31.23
23.84
4.29
28.73
23.10
4.50

72
40.87
20.61
3.90
38.85
19.93
4.13
36.57
19.16
4.34
34.24
18.36
4.54
31.50
17.59
4.78

Model No.: PY048


CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

1500/0.111
62
46.80
43.56
5.32
44.44
42.38
5.37
41.90
40.99
5.59
39.22
38.48
5.82
36.67
35.88
5.96

67
51.50
36.31
5.58
49.10
35.24
5.65
46.37
34.28
5.89
43.50
33.28
6.13
40.71
32.16
6.29

72
56.70
29.01
5.85
54.18
28.01
5.95
51.21
27.04
6.20
48.17
26.08
6.48
45.13
24.99
6.66

EVAPORATOR AIRFLOW, CFM/DR


1650/0.119
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
47.74
52.65
57.96
46.05
38.21
30.25
5.41
5.67
5.96
45.37
50.14
55.33
44.29
37.11
29.22
5.48
5.75
6.05
42.71
47.28
52.34
41.79
36.10
28.28
5.69
5.98
6.31
40.05
44.42
49.22
39.29
35.15
27.31
5.92
6.24
6.60
37.39
41.56
46.16
36.59
34.01
26.23
6.06
6.39
6.77

1875/0.132
62
48.94
47.97
5.55
46.49
45.38
5.61
43.79
42.85
5.82
41.01
40.24
6.05
38.24
37.42
6.20

67
54.06
40.92
5.82
51.45
39.78
5.89
48.53
38.78
6.13
45.52
37.78
6.39
42.59
36.64
6.55

72
59.56
32.03
6.10
56.82
30.97
6.19
53.74
30.02
6.46
50.51
29.04
6.75
47.36
27.95
6.93

Model No.: PY060


CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

1650/0.119
62
56.37
48.70
6.67
53.71
47.63
6.99
50.90
46.48
7.29
48.10
45.39
7.58
45.08
43.38
7.85

TC Total Capacity (1000 Btuh) Gross


SC Sensible Heat Capacity (1000 Btuh) Gross

67
61.80
40.89
7.02
58.87
39.79
7.37
55.87
38.68
7.70
52.79
37.57
8.03
49.57
36.37
8.33

72
67.64
32.93
7.38
64.51
31.87
7.76
61.23
30.78
8.13
57.89
29.68
8.49
54.41
28.50
8.84

kW Total unit power input


DR Wet Bulb depression ratio

EVAPORATOR AIRFLOW, CFM/DR


1875/0.132
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
57.92
63.48
69.59
52.30
43.53
34.70
6.82
7.18
7.52
55.15
60.48
66.35
51.21
42.44
33.64
7.14
7.53
7.91
52.21
57.39
62.96
50.02
41.35
32.53
7.45
7.87
8.30
49.26
54.22
59.48
47.41
40.24
31.42
7.74
8.20
8.67
46.24
50.89
55.85
44.50
39.02
30.21
8.02
8.51
9.02
DBE Dry Bulb Temp. (0F) of Air Entering Coil
WBE Wet Bulb Temp. (0F) of Air Entering Coil

2000/0.139
62
58.65
54.21
6.98
55.77
53.07
7.31
52.90
50.84
7.61
49.85
47.98
7.91
46.80
45.04
8.19

67
64.34
44.98
7.33
61.30
43.90
7.69
58.09
42.76
8.03
54.88
41.65
8.36
51.50
40.43
8.67

DBL Dry Bulb Temp. (0F) of Air Leaving Coil


WBL Wet Bulb Temp. (0F) of Air Leaving Coil

NOTES: 1. Direct interpolation is permissible Do not extrapolate.


2. Capacities above are based on DBE = 800F. For higher or lower DBE, add following Correction Factor to Sensible Capacity = 1.08 x CFM (1 DR) (DBE 80).
3. To calculate leaving conditions, follow this procedure: DBL = DBE (Sensible Capacity (Btuh) / 1.08 x CFM);
WBL = DBL [DR (DBE WBE)].
4. Total unit power input at 0.15 ESP for PY036 & 0.2 ESP for PY048/PY060.

11

72
70.52
35.64
7.68
67.24
34.58
8.08
63.79
33.47
8.46
60.26
32.35
8.84
56.55
31.13
9.20

COOLING CAPACITIES
Model No.: PY075
CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

1900/0.11
62
67.06
58.14
6.92
63.91
56.88
7.36
60.93
55.66
7.85
57.95
54.57
8.39
54.56
53.31
8.99

67
73.14
48.74
7.29
69.85
47.54
7.77
66.72
46.40
8.31
63.42
45.26
8.88
59.80
44.04
9.52

72
79.85
39.29
7.68
76.33
38.11
8.21
72.89
36.95
8.80
69.45
35.88
9.42
65.44
34.61
10.13

EVAPORATOR AIRFLOW, CFM/DR


2400/0.131
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
70.38
76.89
84.00
66.27
54.81
43.26
7.29
7.68
8.08
66.93
73.35
80.28
64.93
53.60
42.09
7.74
8.17
8.63
63.79
69.92
76.66
62.21
52.38
40.94
8.24
8.71
9.23
60.55
66.49
72.93
59.26
51.29
39.84
8.79
9.30
9.88
56.99
62.53
68.69
55.98
49.99
38.57
9.39
9.95
10.60

2900/0.153
62
72.66
70.59
7.75
69.12
67.31
8.20
65.83
64.21
8.71
62.42
61.09
9.26
58.76
57.72
9.86

67
79.58
60.40
8.13
75.81
59.14
8.63
72.29
57.97
9.18
68.64
56.84
9.78
64.62
55.62
10.45

72
87.12
46.93
8.57
83.12
45.71
9.13
79.25
44.49
9.75
75.38
43.40
10.41
71.00
42.15
11.14

Model No.: PY090


CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

2400/0.108
62
81.46
73.14
8.44
77.59
71.53
8.90
73.52
69.80
9.45
69.65
68.36
10.06
65.57
65.23
10.74

67
88.75
61.06
8.83
84.80
59.57
9.34
80.64
58.01
9.95
76.47
56.55
10.62
72.10
55.03
11.39

72
96.62
48.84
9.21
92.59
47.47
9.80
88.14
45.94
10.48
83.79
44.56
11.22
79.14
43.08
12.08

EVAPORATOR AIRFLOW, CFM/DR


3000/0.128
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
85.10
92.86
101.38
82.97
68.39
53.72
8.92
9.31
9.70
81.05
88.70
96.98
80.03
66.90
52.27
9.40
9.85
10.32
76.86
84.28
92.46
75.98
65.29
50.81
9.96
10.47
11.03
72.81
79.99
87.80
72.19
63.90
49.39
10.58
11.16
11.80
68.50
75.43
82.89
68.14
62.40
47.89
11.30
11.95
12.68

3600/0.148
62
87.69
86.46
9.52
83.45
82.40
10.00
79.22
78.31
10.58
74.98
74.34
11.22
70.59
70.22
11.93

67
95.83
75.17
9.91
91.61
73.77
10.46
86.93
72.07
11.11
82.56
70.75
11.81
77.88
69.28
12.62

72
104.74
58.11
10.32
100.24
56.69
10.96
95.43
55.16
11.69
90.62
53.75
12.48
85.66
52.32
13.37

Model No.: PY100


CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

2700/0.109
62
90.59
81.47
9.39
86.12
79.64
9.82
80.82
77.43
10.24
75.88
74.93
10.61
70.71
69.98
10.94

TC Total Capacity (1000 Btuh) Gross


SC Sensible Heat Capacity (1000 Btuh) Gross

67
99.73
68.39
9.88
95.05
66.64
10.36
89.43
64.51
10.81
84.04
62.55
11.22
78.54
60.59
11.59

72
109.63
55.08
10.39
104.86
53.48
10.92
98.69
51.32
11.42
92.99
49.45
11.87
87.05
47.52
12.29

kW Total unit power input


DR Wet Bulb depression ratio

EVAPORATOR AIRFLOW, CFM/DR


3400/0.13
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
95.41
105.24
115.92
93.20
77.20
60.97
9.78
10.28
10.81
90.67
100.23
110.65
89.26
75.41
59.25
10.23
10.77
11.36
84.89
94.19
104.20
83.63
73.20
57.11
10.64
11.23
11.87
79.70
88.59
98.19
78.70
71.30
55.24
11.02
11.65
12.34
74.22
82.69
91.89
73.46
69.27
53.28
11.36
12.03
12.78
DBE Dry Bulb Temp. (0F) of Air Entering Coil
WBE Wet Bulb Temp. (0F) of Air Entering Coil

4100/0.151
62
98.79
97.08
10.34
93.79
92.33
10.79
87.90
86.59
11.21
82.36
81.32
11.59
76.82
76.03
11.94

67
109.14
85.21
10.85
103.98
83.47
11.35
97.58
81.15
11.82
91.72
79.22
12.24
85.67
77.25
12.63

DBL Dry Bulb Temp. (0F) of Air Leaving Coil


WBL Wet Bulb Temp. (0F) of Air Leaving Coil

NOTES: 1. Direct interpolation is permissible Do not extrapolate.


2. Capacities above are based on DBE = 800F. For higher or lower DBE, add following Correction Factor to Sensible Capacity = 1.08 x CFM (1 DR) (DBE 80).
3. To calculate leaving conditions, follow this procedure: DBL = DBE (Sensible Capacity (Btuh) / 1.08 x CFM);
WBL = DBL [DR (DBE WBE)].
4. Total unit power input based on nominal CFM & 0.25 ESP.

12

72
120.35
66.19
11.39
115.05
64.58
11.96
108.33
62.42
12.48
101.97
60.48
12.98
95.25
58.42
13.42

COOLING CAPACITIES
Model No.: PY120
CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

3200/0.105
62
113.22
97.86
11.93
108.34
95.80
12.63
102.48
93.53
13.39
96.91
91.21
13.83
91.33
89.00
15.06

67
124.16
82.33
12.57
119.03
80.37
13.33
112.65
78.08
14.17
106.68
75.86
14.66
100.58
73.73
16.01

72
136.00
66.54
13.21
130.62
64.69
14.05
123.72
62.43
14.98
117.10
60.16
15.53
110.62
58.11
17.02

EVAPORATOR AIRFLOW, CFM/DR


4000/0.124
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
119.04
130.75
143.45
111.20
92.33
73.20
12.57
13.20
13.85
113.81
125.20
137.59
109.11
90.30
71.27
13.27
13.98
14.73
107.54
118.44
130.34
104.40
88.01
69.03
14.07
14.85
15.70
101.61
112.02
123.28
98.74
85.71
66.71
14.51
15.35
16.27
95.69
105.61
116.38
93.25
83.60
64.63
15.77
16.73
17.80

4800/0.143
62
123.19
119.14
13.31
117.75
114.00
14.03
111.27
108.02
14.83
104.99
102.02
15.28
98.72
96.20
16.56

67
135.47
101.49
13.95
129.64
99.44
14.75
122.57
97.14
15.64
115.91
94.84
16.15
109.25
92.76
17.56

72
148.97
79.27
14.62
142.76
77.28
15.52
135.10
74.99
16.51
127.86
72.71
17.11
120.62
70.60
18.67

Model No.: PY150


CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

3800/0.119
62
132.46
116.86
15.50
126.50
114.48
16.56
120.21
111.97
17.73
114.08
109.75
18.94
106.80
106.64
20.42

67
144.81
98.10
16.36
138.55
95.87
17.51
131.46
93.19
18.76
124.87
90.99
20.06
116.97
87.95
21.66

72
158.22
79.11
17.26
151.34
76.82
18.51
143.81
74.26
19.88
136.60
72.00
21.29
128.09
69.07
23.04

EVAPORATOR AIRFLOW, CFM/DR


4800/0.143
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
138.46
151.70
165.93
132.72
109.96
86.83
16.47
17.34
18.29
132.18
144.83
158.69
130.42
107.59
84.58
17.55
18.51
19.58
125.49
137.55
150.62
124.68
105.06
81.96
18.73
19.79
20.97
118.80
130.47
142.97
118.49
102.81
79.69
19.96
21.12
22.43
111.27
122.15
134.07
111.10
99.77
76.79
21.45
22.74
24.23

5800/0.167
62
142.79
141.17
17.67
136.22
135.06
18.76
129.14
128.31
19.95
122.32
122.00
21.19
114.48
114.31
22.70

67
156.65
120.81
18.55
149.61
118.55
19.74
141.82
115.86
21.03
134.27
113.48
22.38
125.72
110.50
24.03

72
171.50
93.81
19.57
164.00
91.59
20.88
155.75
89.05
22.30
147.50
86.63
23.78
138.25
83.71
25.60

Model No.: PY180


CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

4800/0.177
62
163.97
142.89
18.11
156.86
138.23
19.09
147.66
132.49
19.98
139.08
126.87
21.92
129.88
122.94
23.01

TC Total Capacity (1000 Btuh) Gross


SC Sensible Heat Capacity (1000 Btuh) Gross

67
180.21
120.79
18.96
172.51
116.38
20.03
162.52
110.98
21.01
153.16
105.71
23.11
143.38
102.02
24.31

72
197.59
98.18
19.78
189.52
94.20
20.96
178.76
89.21
22.05
168.62
84.36
24.33
157.86
80.69
25.66

kW Total unit power input


DR Wet Bulb depression ratio

EVAPORATOR AIRFLOW, CFM/DR


6000/0.22
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
171.50
188.58
207.16
158.60
132.49
106.04
19.33
20.16
20.98
163.92
180.52
198.62
153.73
127.99
101.95
20.32
21.25
22.20
154.25
170.12
187.24
147.79
122.51
96.82
21.24
22.26
23.33
145.10
160.23
176.64
140.06
117.01
91.86
23.21
24.40
25.65
135.42
149.83
165.26
130.68
113.21
88.11
24.32
25.63
27.04
DBE Dry Bulb Temp. (0F) of Air Entering Coil
WBE Wet Bulb Temp. (0F) of Air Entering Coil

7200/0.264
62
177.25
172.09
20.78
169.10
166.81
21.78
159.06
155.95
22.71
149.65
144.45
24.71
139.61
134.72
25.84

67
195.09
142.56
21.60
186.66
137.91
22.71
175.73
132.21
23.74
165.12
126.27
25.91
154.51
122.57
27.16

DBL Dry Bulb Temp. (0F) of Air Leaving Coil


WBL Wet Bulb Temp. (0F) of Air Leaving Coil

NOTES: 1. Direct interpolation is permissible Do not extrapolate.


2. Capacities above are based on DBE = 800F. For higher or lower DBE, add following Correction Factor to Sensible Capacity = 1.08 x CFM (1 DR) (DBE 80).
3. To calculate leaving conditions, follow this procedure: DBL = DBE (Sensible Capacity (Btuh) / 1.08 x CFM);
WBL = DBL [DR (DBE WBE)].
4. Total unit power input based on nominal CFM & 0.35 ESP.

13

72
214.45
112.68
22.43
205.45
108.44
23.68
193.66
103.23
24.84
182.48
98.06
27.21
170.69
94.28
28.61

COOLING CAPACITIES
Model No.: PY210
CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

5800/0.117
62
193.33
172.74
20.67
183.73
168.85
21.57
171.60
163.06
22.44
159.72
155.25
23.24
149.11
145.15
24.94

67
212.72
144.91
21.89
202.41
141.10
22.88
189.34
135.55
23.82
176.26
129.98
24.70
164.95
125.98
26.55

72
233.75
116.72
23.09
222.50
112.90
24.17
208.25
107.52
25.22
194.25
102.30
26.18
182.00
98.36
28.20

EVAPORATOR AIRFLOW, CFM/DR


7000/0.136
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
201.31
221.84
244.09
192.16
159.50
126.44
22.27
23.49
24.71
191.24
210.91
232.33
187.32
155.60
122.62
23.19
24.49
25.81
178.43
197.25
217.24
174.13
149.98
117.07
24.07
25.45
26.87
165.93
183.60
202.46
161.28
144.30
111.69
24.88
26.35
27.87
154.95
171.76
189.48
150.83
140.28
107.63
26.61
28.23
29.93

8200/0.154
62
207.59
202.99
23.84
196.87
192.84
24.77
183.65
179.23
25.65
170.79
166.00
26.48
159.71
155.47
28.22

67
228.94
173.15
25.05
217.56
169.21
26.07
203.34
163.45
27.05
189.12
157.58
27.96
176.68
153.37
29.87

72
251.66
135.14
26.30
239.64
131.41
27.42
224.09
125.83
28.50
208.89
120.42
29.52
195.46
116.32
31.62

Model No.: PY240


CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

6000/0.095
62
227.71
195.56
25.19
216.21
190.98
26.65
205.23
186.45
28.08
192.68
181.31
29.60
179.35
175.82
30.30

67
249.71
165.51
26.42
237.23
160.83
28.01
225.26
156.23
29.59
211.99
151.35
31.26
197.69
146.01
32.07

72
273.36
134.79
27.68
260.43
130.41
29.45
247.50
125.88
31.20
233.02
120.95
33.06
217.50
115.65
34.01

EVAPORATOR AIRFLOW, CFM/DR


7500/0.112
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
240.52
264.02
289.66
222.35
185.57
148.34
26.39
27.64
28.95
227.78
250.69
275.43
217.42
180.90
143.74
27.89
29.28
30.81
216.01
237.68
261.85
212.84
176.09
139.27
29.35
30.91
32.62
202.61
223.37
246.34
201.77
171.05
134.23
30.90
32.63
34.56
188.56
208.09
229.85
188.20
165.60
128.87
31.63
33.48
35.57

9000/0.128
62
249.41
246.42
27.82
236.08
234.01
29.33
223.53
221.99
30.83
209.80
208.93
32.41
194.90
194.53
33.15

67
274.29
204.04
29.07
260.25
199.33
30.76
246.59
194.46
32.43
231.76
189.51
34.18
215.77
183.99
35.06

72
301.42
160.53
30.46
286.68
156.01
32.38
271.94
151.23
34.24
255.65
146.12
36.23
238.58
140.80
37.27

Model No.: PY300


CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

8000/0.117
62
272.59
248.18
28.59
259.00
242.26
30.97
245.05
236.91
32.93
229.37
224.78
35.03
212.29
208.04
36.39

TC Total Capacity (1000 Btuh) Gross


SC Sensible Heat Capacity (1000 Btuh) Gross

67
299.31
208.42
29.97
285.09
202.89
32.54
269.83
197.37
34.69
253.18
191.26
37.01
234.45
184.39
38.53

72
328.28
168.04
31.41
313.10
162.67
34.23
296.90
157.32
36.61
278.62
151.10
39.18
258.62
144.45
40.92

kW Total unit power input


DR Wet Bulb depression ratio

EVAPORATOR AIRFLOW, CFM/DR


9600/0.135
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
282.35
310.89
341.79
274.35
228.20
181.23
30.19
31.57
33.08
268.55
295.91
325.66
263.18
222.60
175.72
32.59
34.19
35.96
253.91
279.68
308.28
248.83
216.89
170.15
34.58
36.38
38.40
237.59
262.20
289.66
232.84
210.70
164.16
36.73
38.74
41.03
219.61
242.64
268.55
215.22
203.77
157.35
38.10
40.31
42.83
DBE Dry Bulb Temp. (0F) of Air Entering Coil
WBE Wet Bulb Temp. (0F) of Air Entering Coil

11200/0.153
62
290.37
284.56
32.07
275.73
270.22
34.49
260.11
254.91
36.51
243.52
238.65
38.67
224.98
220.48
40.08

67
319.49
246.43
33.47
303.95
240.81
36.13
287.45
235.32
38.36
269.48
229.22
40.75
249.09
222.11
42.35

DBL Dry Bulb Temp. (0F) of Air Leaving Coil


WBL Wet Bulb Temp. (0F) of Air Leaving Coil

NOTES: 1. Direct interpolation is permissible Do not extrapolate.


2. Capacities above are based on DBE = 800F. For higher or lower DBE, add following Correction Factor to Sensible Capacity = 1.08 x CFM (1 DR) (DBE 80).
3. To calculate leaving conditions, follow this procedure: DBL = DBE (Sensible Capacity (Btuh) / 1.08 x CFM);
WBL = DBL [DR (DBE WBE)].
4. Total unit power input based on nominal CFM & 0.35 ESP.

14

72
351.93
193.22
35.05
335.03
187.59
37.97
317.66
182.36
40.46
297.86
176.05
43.15
276.14
169.26
44.98

COOLING CAPACITIES
Model No.: PY340
CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

9000/0.128
62
298.04
277.60
32.18
283.14
271.46
33.37
264.71
262.16
35.17
248.63
243.65
37.11
230.20
225.59
38.45

67
327.36
232.80
33.76
311.36
226.76
35.09
291.46
217.85
37.06
274.29
211.39
39.20
254.00
203.13
40.72

72
359.22
187.34
35.43
341.77
181.25
36.93
320.82
173.05
39.11
301.81
166.40
41.50
280.47
158.76
43.23

EVAPORATOR AIRFLOW, CFM/DR


10500/0.145
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
306.54
337.30
370.67
301.61
250.80
199.18
34.15
35.75
37.48
291.44
320.46
353.02
285.61
244.59
193.34
35.37
37.11
39.01
272.68
300.43
330.84
267.23
236.01
184.81
37.19
39.11
41.25
255.75
282.23
311.38
250.64
229.21
178.25
39.15
41.29
43.68
236.54
261.29
288.75
231.81
220.89
170.24
40.52
42.84
45.46

12000/0.162
62
313.73
307.45
36.11
298.04
292.08
37.34
278.69
273.12
39.18
261.44
256.21
41.16
241.57
236.74
42.54

67
345.43
267.86
37.72
328.27
261.79
39.10
307.46
252.96
41.13
288.73
246.13
43.34
267.40
237.89
44.92

72
380.17
210.38
39.51
361.55
204.30
41.08
339.31
196.02
43.34
319.14
189.35
45.82
295.86
181.26
47.63

Model No.: PY360


CONDENSER
ENTERING AIR
TEMP. (0F)
85

95

105

115

125

TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW

9600/0.066
62
335.06
302.30
36.89
326.69
298.64
39.19
315.40
290.53
41.25
303.69
282.58
43.55
292.81
275.10
45.6

TC Total Capacity (1000 Btuh) Gross


SC Sensible Heat Capacity (1000 Btuh) Gross

67
363.33
251.13
37.66
354.59
247.70
40
342.94
240.62
42.11
330.45
233.36
44.45
318.80
226.53
46.55

72
393.52
199.36
38.35
384.41
196.16
40.77
372.00
189.80
42.95
358.34
183.10
45.36
346.34
177.21
47.54

kW Total unit power input


DR Wet Bulb depression ratio

EVAPORATOR AIRFLOW, CFM/DR


11250/0.078
EVAPORATOR ENTERING AIR, WBE (0F)
62
67
72
344.61
374.08
405.39
330.90
272.29
212.94
38.29
39.02
39.75
335.78
364.81
395.69
325.71
268.75
209.62
40.58
41.36
42.17
324.51
352.62
382.60
311.53
261.38
203.02
42.64
43.46
44.35
312.25
339.45
369.02
296.64
253.75
196.47
44.92
45.8
46.78
300.98
327.75
355.93
282.92
246.98
190.11
46.98
47.9
48.97
DBE Dry Bulb Temp. (0F) of Air Entering Coil
WBE Wet Bulb Temp. (0F) of Air Entering Coil

12500/0.088
62
350.22
339.71
39.44
341.50
331.26
41.72
329.52
316.34
43.78
316.99
301.14
46.05
305.56
287.22
48.1

67
380.42
287.58
40.14
371.21
284.25
42.48
358.74
276.72
44.58
345.20
268.86
46.92
332.73
261.55
49.03

DBL Dry Bulb Temp. (0F) of Air Leaving Coil


WBL Wet Bulb Temp. (0F) of Air Leaving Coil

NOTES: 1. Direct interpolation is permissible Do not extrapolate.


2. Capacities above are based on DBE = 800F. For higher or lower DBE, add following Correction Factor to Sensible Capacity = 1.08 x CFM (1 DR) (DBE 80).
3. To calculate leaving conditions, follow this procedure: DBL = DBE (Sensible Capacity (Btuh) / 1.08 x CFM);
WBL = DBL [DR (DBE WBE)].
4. Total unit power input based on nominal CFM & 0.55 ESP.

15

72
412.72
222.81
40.9
402.48
219.33
43.33
389.55
212.87
45.51
375.00
205.86
47.96
362.07
199.64
50.16

ELECTRICAL DATA
MODEL No.: PY036
POWER
SUPPLY
(V-Ph-Hz)

208/230-1-60

208/230-3-60

380-3-60
(4 WIRE)

460-3-60

VOLTAGE
RANGE

FM

MIN. MAX.

FLA

187

187

342

414

253

253

418

506

2.3

2.3

2.3

0.9

MODEL No.: PY048


COMPRESSOR

BLOWER
MOTOR

RLA

HP

16.7

11.8

5.6

5.4

LRA

84

67

39

29.2

0.5

0.5

0.5

0.5

FLA

1.8

1.8

1.8

0.83

ELECTRIC
HEATER
kW

MCA MOCP

FLA

208/230-3-60

380-3-60
(4 WIRE)

460-3-60

VOLTAGE
RANGE

FM

COMPRESSOR

BLOWER
MOTOR

MIN. MAX.

FLA

RLA

HP

187

342

414

253

418

506

2.3

2.3

0.9

19.6

10.4

10.4

LRA

105

55

55

0.75

0.75

0.75

FLA

4.7

4.7

2.6

- Fan Motor

HP

- Horse Power

FLA

- Full Load Amps

RLA

- Rated Load Amps

LRA

- Locked Rotor Amps

MCA

- Minimum Circuit Amps

MAX.

FM

COMPRESSOR

BLOWER
MOTOR

FLA

RLA

HP

LRA

FLA

ELECTRIC
HEATER
kW

MCA MOCP

FLA

25

40

37.8

21.7

29.4

40

21.7

37.8

60

7.5

32.6

43

45

7.5

32.6

46.6

60

10*

43.5

56.6

60

10*

43.5

60.3

70

18.9

30

27

40
40

12.6

18.9

30

7.5

18.8

25.8

30

10*

25.1

33.6

7.6

7.5

208/230-1-60

187

253

2.3

24.6

132

0.75

4.7

60

12.6

27

7.5

18.8

29.4

40

35

10*

25.1

37.3

40

11.1

15

17.3

25

11.8

15

7.6

17.3

25

11.4

16.5

20

7.5

11.4

20.1

25

10*

15.2

21.3

25

10*

15.2

24.9

25

8.5

15

13.8

20

6.3

8.9

15

7.5

9.4

12.8

15

10*

12.6

16.8

20

208/230-3-60

380-3-60
(4 WIRE)

460-3-60

ELECTRIC
HEATER
kW

MCA MOCP

FLA

31.5

12.6

31.5

50
50

7.5

18.8

31.5

50

10*

25.1

37.3

50

20

30
30

7.6

20

7.5

11.4

20.1

30

10*

15.2

24.9

30

16.5

25

6.3

16.5

25

7.5

9.4

16.5

25

10*

12.6

19

25

LEGEND:
FM

VOLTAGE
RANGE
MIN.

MODEL No.: PY060


POWER
SUPPLY
(V-Ph-Hz)

POWER
SUPPLY
(V-Ph-Hz)

MOCP - Maximum Over Current Protection

* Combination of 2 heater modules


16

187

342

414

253

418

506

2.3

2.3

0.9

16

8.2

8.2

97

50

50

0.75

0.75

0.75

4.7

4.7

2.6

6.3

13.8

20

7.5

9.4

15

20

10*

12.6

19

20

ELECTRICAL DATA
MODELS: PY075 & PY090
MODEL NUMBER

DESCRIPTION

POWER SUPPLY
(V-Ph-Hz)

PY075

VOLTAGE
RANGE
Min.

Max.

FM

COMPRESSOR

FLA

RLA LRA HP FLA Nom. kW

ELECTRIC
HEATER

BM

1.5 5.6
(STD)

187

253

2.5
20.7 156
(3.8 FOR
PY090)
2
(ALT.)

6.6

342

418

2.5

10.7

5/6

12.6/15.1

34/34

50/50

7.5/10

18.8/25.1

34/38.4

50/50

* *
15 *

2
(ALT.)

54.1

60

35

50

5/6

12.6/15.1

35/35

50/50

7.5/10

18.8/25.1

35/39.6

50/50

414

506

1.3
(1.8 FOR
PY090)

10

2
(ALT.)

3.5

FM

- Fan Motor (Condenser)

BM

- Blower Motor

FLA

- Full Load Amps

RLA

- Rated Load Amps

LRA

- Locked Rotor Amps

MCA

- Minimum Circuit Amps

7.5/10

18.8/25.1 39.9/39.9

50/50

10 /12

* *
15*/20*
25*/30*

25.1/30.1 39.9/45.9

50/50

37.7/50.2

60/80

55.4/71

62.8/75.3 86.8/102.4
42.1

90/110
50

5/6

12.6/15.1 42.1/42.1

50/50

7.5/10

18.8/25.1 42.1/42.4

50/50

10 /12

25.1/30.1 42.4/48.6

50/50

37.7/50.2 58.1/73.8

60/80

55.4

60

19.3

25

24.2

30

5/6

7.6/9.1

19.3/19.3

25/25

5/6

7.6/9.1

24.2/24.2

30/30

11.4/15.2 19.3/23.3

25/25

15.2/18.2

7.5/10

* *
*

50/50

23.3/27

25/30

22.8

32.8

35

19.9

30

5/6

7.6/9.1

19.9/19.9

30/30

7.5/10

11.4/15.2

19.9/24

30/30

15.2/18.2

24/27.8

30/30

33.5

35

22.8

16.6

25

5/6

6.3/7.5

16.6/16.6

25/25

7.5/10

9.4/12.6

16.6/19.3

25/25

12.6/15.1 19.3/22.4

25/25

* *
15 *

10 /12

18.8

27

30

17.3

25

5/6

6.3/7.5

17.3/17.3

25/25

7.5/10

9.4/12.6

17.3/20.1

25/25

12.6/15.1 20.1/23.3

25/25

* *
15 *

18.8

MOCP - Maximum Over Current Protection

*Combination of heater

50
50/50

25.1/30.1 39.6/45.9

LEGEND:
- Horse Power

8.8

39.9

12.6/15.1 39.9/39.9

37.7

10 /12

HP

3
(ALT.)

5/6

* *
*

74

13.1 80

MOCP

* *
15*/20*
25*/30*

15

460-3-60

2
6.6
(STD)

MCA

FLA

50/50

37.7

10 /12

1.5
2.8
(STD)

25.1/30.1 38.4/44.6

15

(1.7 FOR
PY090)

ELECTRIC
HEATER

BM

RLA LRA HP FLA


50

* *
15 *

72

FLA
34

10 /12
380-3-60 (4 WIRE)

MOCP

10 /12

1.5 3.4
(STD)

MCA

10 /12
208/230-3-60

PY090
COMPRESSOR
(each)

modules

17

27.9

30

2
(STD)

8.2

50

3
5.14
(ALT.)

7.5/10

11.4/15.2

24.2/24.2

30/30

10 /12

15.2/18.2

24.2/27.8

30/30

22.8/30.4

33.5/43

35/45

38/45.6

52.5/62

60/70

25.3

30

5/6

7.6/9.1

25.3/25.3

30/30

* *
15*/20*
25*/30*
7.5/10

11.4/15.2

25.3/25.4

30/30

10 /12

15.2/18.2

25.4/29.2

30/30

* *
15*/20*
25*/30*

5/6

2
(STD)

5.9

3.5

42

3
(ALT.)

4.1

62.8/75.3 89.5/105.1 100/110

7.5/10

* *
15*/20*
25*/30*

10 /12

22.8/30.4 34.9/44.4
38/45.6

53.9/63.4

40/45
60/70

18.6

20

6.3/7.5

18.6/18.6

20/20

9.4/12.6

18.6/20.1

20/25

12.6/15.1 20.1/23.3

25/25

18.8/25.1 27.9/35.8

30/40
45/60

31.4/37.7

43.6/51.5

19.2

25

5/6

6.3/7.5

19.2/19.2

25/25

9.4/12.6

19.2/20.9

25/25

12.6/15.1

20.9/24

25/25

7.5/10

* *
15*/20*
25*/30*

10 /12

18.8/25.1 28.6/36.5

30/40

31.4/37.7

45/60

44.4/52.3

ELECTRICAL DATA
MODELS: PY100 & PY120
MODEL NUMBER

DESCRIPTION

POWER SUPPLY
(V-Ph-Hz)

PY100

VOLTAGE
RANGE
Min.

Max.

FM

COMPRESSOR
(each)

FLA

RLA LRA HP FLA Nom. kW

ELECTRIC
HEATER

BM

2
6.6
(STD)

208/230-3-60

187

253

3.8

16

97

3
(ALT.)

2
(STD)

380-3-60 (4 WIRE)

342

418

1.7

8.2

8.8

50

3
5.14
(ALT.)

414

506

1.8

8.2

50

3
(ALT.)

4.1

FLA
60

5/6

12.6/15.1

46.4/46.4

60/60

7.5/10

18.8/25.1 46.4/46.4

60/60

10 /12

25.1/30.1 46.4/46.4

60/60

* *
15*/20*
25*/30*

37.7/50.2

- Horse Power

FM

- Fan Motor (Condenser)

BM

- Blower Motor

FLA

- Full Load Amps

RLA

- Rated Load Amps

LRA

- Locked Rotor Amps

MCA

- Minimum Circuit Amps

48.6

60

12.6/15.1

48.6/48.6

60/60

7.5/10

18.8/25.1 48.6/48.6

60/60

10 /12

25.1/30.1 48.6/48.6

60/60

37.7/50.2

60/80

58.1/73.8

24.2

30

7.6/9.1

24.2/24.2

30/30

7.5/10

11.4/15.2

24.2/24.2

30/30

10 /12

15.2/18.2

24.2/27.8

30/30

22.8/30.4

33.5/43

35/45

38/45.6

52.5/62

60/70

25.3

30

5/6

7.6/9.1

25.3/25.3

30/30

7.5/10

11.4/15.2

25.3/25.4

30/30

10 /12

15.2/18.2

25.4/29.2

30/30

22.8/30.4

34.9/44.4

40/45

38/45.6

53.9/63.4

60/70

* *
15*/20*
25*/30*
7.5/10

* *
15*/20*
25*/30*

10 /12

23.8

30

6.3/7.5

23.8/23.8

30/30

9.4/12.6

23.8/23.8

30/30

12.6/15.1 23.8/23.8

30/30

18.8/25.1

27.9/35.8

30/40

31.4/37.7

43.6/51.5

45/60

24.4

30

5/6

6.3/7.5

24.4/24.4

30/30

9.4/12.6

24.4/24.4

30/30

12.6/15.1 24.4/24.4

30/30

7.5/10

* *
15*/20*
25*/30*

10 /12

19.6 105

3
8.8
(STD)

MCA

MOCP

FLA

56.7

70

5/6

12.6/15.1 56.7/56.7

70/70

7.5/10

18.8/25.1 56.7/56.7

70/70

* *

25.1/30.1 56.7/56.7

70/70

* *

37.7/50.2 58.1/73.8

70/80

* *

62.8/75.3 89.5/105.1 100/110

10 /12

15 /20
25 /30

62.8/75.3 89.5/105.1 100/110

5/6

* *
15*/20*
25*/30*

ELECTRIC
HEATER

60/80
90/110

18.8/25.1

28.6/36.5

30/40

31.4/37.7

44.4/52.3

45/60

MOCP - Maximum Over Current Protection

*Combination of heater

55.4/71

62.8/75.3 86.8/102.4

5/6

* *
15*/20*
25*/30*

BM

RLA LRA HP FLA Nom. kW


46.4

LEGEND:
HP

MOCP

2
3.5
(STD)

MCA

5/6

460-3-60

PY120
COMPRESSOR
(each)

modules

18

10.4 55

3
5.14
(STD)

30.2

40

5/6

7.6/9.1

30.2/30.2

40/40

7.5/10

11.4/15.2

30.2/30.2

40/40

* *

15.2/18.2 30.2/30.2

40/40

* *

22.8/30.4 34.9/44.4

40/45

10 /12
15 /20

* *

25 /30

10.4 55

3
(STD)

4.1

38/45.6

53.9/63.4

60/70

29.3

35

5/6

6.3/7.5

29.3/29.3

35/35

7.5/10

9.4/12.6

29.3/29.3

35/35

* *

12.6/15.1 29.3/29.3

35/35

* *

18.8/25.1 29.3/36.5

35/40

* *

31.4/37.7

45/60

10 /12

15 /20
25 /30

44.4/52.3

ELECTRICAL DATA
MODELS: PY150 & PY180
MODEL NUMBER

DESCRIPTION

POWER SUPPLY
(V-Ph-Hz)

PY150

VOLTAGE
RANGE
Min.

FM
COMPR(each)
ESSOR
(1 for PY150 &
2 for PY180) (each)

Max.

FLA

BM

ELECTRIC
HEATER

RLA LRA HP FLA Nom. kW

3
8.8
(STD)

208/230-3-60

187

253

3.8

20.7 156

3 5.14
(STD)

380-3-60 (4 WIRE)

342

418

1.7

10.7

72

5
(ALT.)

8.4

414

506

1.8

10

74

5
(ALT.)

6.4

- Horse Power

FM

- Fan Motor (Condenser)

BM

- Blower Motor

FLA

- Full Load Amps

RLA

- Rated Load Amps

LRA

- Locked Rotor Amps

MCA

- Minimum Circuit Amps

18.8/25.1 59.2/59.2

70/70

25.1/30.1 59.2/59.2

70/70

37.7/50.2 59.2/73.8

70/80

* *
15*/20*
25*/30*

62.8/75.3 89.5/105.1 100/110

63.1

80

5/6

12.6/15.1 63.1/63.1

80/80

7.5/10

18.8/25.1 63.1/63.1

80/80

10 /12

25.1/30.1 63.1/63.1

80/80

* *
15*/20*
25*/30*

37.7/50.2 63.1/78.6
94.4/110

100/125

30.9

40

5/6

7.6/9.1

30.9/30.9

40/40

7.5/10

11.4/15.2

30.9/30.9

40/40

10 /12

15.2/18.2

30.9/30.9

40/40

22.8/30.4 34.9/44.4
53.9/63.4

60/70

34.2

40

5/6

7.6/9.1

34.2/34.2

40/40

7.5/10

11.4/15.2

34.2/34.2

40/40

10 /12

15.2/18.2

34.2/34.2

40/40

22.8/30.4

39/48.5

40/50

38/45.6

58/67.5

60/70

28.4

35

6.3/7.5

28.4/28.4

35/35

9.4/12.6

28.4/28.4

35/35

12.6/15.1 28.4/28.4

35/35

7.5/10

* *
15*/20*
25*/30*

10 /12

18.8/25.1 28.6/36.5

35/40

31.4/37.7

44.4/52.3

45/60

30.7

40

5/6

6.3/7.5

30.7/30.7

40/40

9.4/12.6

7.5/10

* *
15*/20*
25*/30*

10 /12

30.7/30.7

40/40

12.6/15.1 30.7/30.7

40/40

18.8/25.1 31.5/39.4

40/40

31.4/37.7

50/60

modules

19

47.3/55.1

5
12.7
(STD)

32.1 195
&
&
25 164

* *
* *
25*/30*

7.5 20.4
(ALT.)

16.7 123
&
&
12 100

6.4

16.4 95
&
&
12 101
10.2

110
110/110
110/110

62.8/75.3

94.4/110

110/110

93.1

125

* *
* *
25*/30*

10 /12

25.1/30.1 93.1/93.1

125/125

15 /20

37.7/50.2 93.1/93.1

125/125

62.8/75.3 104/119.6

125/125

* *
* *
25*/30*

44.7

60

10 /12

15.2/18.2 44.7/44.7

60/60

15 /20

22.8/30.4 44.7/48.5

60/60

* *
* *
25*/30*

38/45.6

58/67.5

60/70

50.4

60

10 /12

15.2/18.2 50.4/50.4

60/60

15 /20

22.8/30.4 50.4/55.6

60/60

38/45.6

65.1/74.6

70/80

42.5

50

10 /12

12.6/15.1

42.5/42.5

50/50

15 /20

18.8/25.1 42.5/42.5

50/50

31.4/37.7

47.3/55.1

50/60

46.3

60

10 /12

12.6/15.1

46.3/46.3

60/60

15 /20

18.8/25.1 46.3/46.3

60/60

31.4/37.7

60/60

* *
* *
25*/30*

7.5
(ALT.)

25.1/30.1 85.4/85.4

5
(STD)

85.4

FLA

37.7/50.2 85.4/85.4

7.5 14.1
(ALT.)

MOCP

15 /20

5
8.4
(STD)

MCA

10 /12

40/45

38/45.6

* *
15*/20*
25*/30*

ELECTRIC
HEATER

80/80

62.8/75.3

* *
15*/20*
25*/30*

BM

RLA LRA HP FLA Nom. kW

7.5/10

MOCP - Maximum Over Current Protection

*Combination of heater

70

10 /12

LEGEND:
HP

59.2

FLA
70/70

5/6

460-3-60

MOCP

12.6/15.1 59.2/59.2

3
4.1
(STD)

MCA

5/6

5
12.7
(ALT.)

PY180
COMPRESSOR
(each)

* *
* *
25*/30*

52/59.9

ELECTRICAL DATA
MODELS: PY210 & PY240
MODEL NUMBER

DESCRIPTION

POWER SUPPLY
(V-Ph-Hz)

PY210

VOLTAGE
RANGE
Min.

FM
(each)

Max.

FLA

COMPRESSOR
(each)

BM

ELECTRIC
HEATER

RLA LRA HP FLA Nom. kW

5
12.7
(STD)

208/230-3-60

187

253

3.8
33.6 225
(5.4 FOR
PY240)
7.5 20.4
(ALT.)

342

418

1.7

5
6.4
(STD)

1.8
17.3 114
(2.7 FOR
PY240)

95.9/95.9

125/125

62.8/75.3

95.9/110

125/125

103.6

125

* *
* *
25*/30*

10 /12

25.1/30.1 103.6/103.6 125/125

15 /20

37.7/50.2 103.6/103.6 125/125


62.8/75.3

104/119.6

125/125

53.7

70

* *
15*/20*
25*/30*

15.2/18.2 53.7/53.7

70/70

22.8/30.4

53.7/53.7

70/70

38/45.6

58/67.5

70/70

59.4

70

10 /12

* *
* *
25*/30*

15.2/18.2 59.4/59.4

70/70

15 /20

22.8/30.4

59.4/59.4

70/70

38/45.6

65.1/74.6

70/80

48.9

60

12.6/15.1

48.9/48.9

60/60

18.8/25.1

48.9/48.9

60/60

31.4/37.7

48.9/55.1

60/60

52.7

70

10 /12

12.6/15.1

52.7/52.7

70/70

15 /20

18.8/25.1

52.7/52.7

70/70

31.4/37.7

52.7/59.9

70/70

* *
15*/20*
25*/30*

10.2

* *
* *
25*/30*

- Horse Power

FM

- Fan Motor (Condenser)

BM

- Blower Motor

FLA

- Full Load Amps

RLA

- Rated Load Amps

LRA

- Locked Rotor Amps

MCA

- Minimum Circuit Amps

MOCP - Maximum Over Current Protection

*Combination of heater

modules

20

ELECTRIC
HEATER

42

239

7.5 20.4
(STD)

125.7

150

FLA

* *

37.7/50.2 125.7/125.7 150/150

* *

62.8/75.3 125.7/125.7 150/150

* *

87.9/100.4 135.4/151 150/175

15 /20

35 /40

72.4

90

* *

15.2/18.2

72.4/72.4

90/90

* *

22.8/30.4

72.4/72.4

90/90

* *

38/45.6

72.4/74.6

90/90

* *

53.2/60.8

84.1/93.6

90/100

10 /12

15 /20

25 /30

35 /40

58.8

70

* *

12.6/15.1 58.8/58.8

70/70

* *

18.8/25.1

58.8/58.8

70/70

* *

31.4/37.7

58.8/59.9

70/70

* *

43.9/50.2

67.6/75.5

70/80

10 /12

7.5 10.2
(STD)

MOCP

25.1/30.1 125.7/125.7 150/150

25 /30

7.5 14.1
(STD)

MCA

* *

10 /12

19.2 125

LEGEND:

BM

RLA LRA HP FLA Nom. kW

37.7/50.2

7.5
(ALT.)

HP

125
125/125

10 /12

506

23.5 145

7.5 14.1
(ALT.)

414

95.9

FLA

18.6 140

(2.7 FOR
PY240)

460-3-60

MOCP

25.1/30.1 95.9/95.9

10 /12

380-3-60 (4 WIRE)

MCA

* *
15*/20*
25*/30*

10 /12

5
8.4
(STD)

PY240
COMPRESSOR
(each)

15 /20

25 /30

35 /40

ELECTRICAL DATA
MODELS: PY300 & PY340
MODEL NUMBER

DESCRIPTION

POWER
SUPPLY
(V-Ph-Hz)

PY300

VOLTAGE
RANGE
Min.

Max.

FM
(each)
FLA

COMPRESSOR
(each)

BM

ELECTRIC
HEATER

RLA LRA HP FLA Nom. kW

* *
15 */20*
25 */30*
35 */40*

10 /12
7.5 20.4
(STD)

208/230-3-60

187

253

5.4

47.1 245

* *
15 */20*
25 */30*
35 */40*

10 /12
10 24.5
(ALT.)

* *
15 */20*
25 */30*
35 */40*

10 /12
7.5 14.1
(STD)

380-3-60 (4 WIRE)

342

418

2.7

24.4 145

* *
15 */20*
25 */30*
35 */40*

10 /12
10 15.8
(ALT.)

* *
15 */20*
25 */30*
35 */40*

10 /12
7.5 10.2
(STD)

460-3-60

414

506

2.7

19.6 125

* *
15 */20*
25 */30*
35 */40*

10 /12
10
12.2
(ALT.)

PY340

- Horse Power

BM

- Blower Motor

FM

- Fan Motor (Condenser)

RLA

- Rated Load Amps

FLA

- Full Load Amps

LRA

- Locked Rotor Amps

MCA

- Minimum Circuit Amps

137.2

175

BM

7.5 20.4
(STD

62.8/75.3 137.2/137.2 175/175


87.9/100.4 137.2/151 175/175
141.3

175

53.6 300

25.1/30.1 141.3/141.3 175/175


10 24.5
(ALT.)

62.8/75.3 141.3/141.3 175/175


87.9/100.4 141.3/156.1 175/175

74.4

90

74.4/74.4

90/90

22.8/30.4

74.4/74.4

90/90

38/45.6

74.4/74.6

90/90

53.2/60.8

84.1/93.6

90/100

76.1

100

15.2/18.2

76.1/76.1

100/100

22.8/30.4

76.1/76.1

100/100

38/45.6
53.2/60.8

59.7

12.6/15.1 59.7/59.7

70/70

59.7/59.9

70/70

43.9/50.2

67.6/75.5

70/80

61.7

12.6/15.1 61.7/61.7

80

10 15.8
(ALT.)

61.7/61.7

80/80

31.4/37.7

61.7/62.4

80/80

43.9/50.2

70.1/78

80/80

* *
15 */20*
25 */30*
35 */40*

10 /12
7.5 10.2
(STD)

25

150

80/80

18.8/25.1

* *
15 */20*
25 */30*
35 */40*

10 /12

70

59.7/59.7

21

28.6 139

70/70

31.4/37.7

modules

7.5 14.1
(STD)

100/100

18.8/25.1

* *
15 */20*
25 */30*
35 */40*

10 /12

76.1/76.8 100/100
86.3/95.8

* *
15 */20*
25 */30*
35 */40*

10 /12

37.7/50.2 141.3/141.3 175/175

15.2/18.2

* *
15 */20*
25 */30*
35 */40*

10 /12

37.7/50.2 137.2/137.2 175/175

ELECTRIC
HEATER

RLA LRA HP FLA Nom. kW

25.1/30.1 137.2/137.2 175/175

MOCP - Maximum Over Current Protection

*Combination of heater

MOCP

FLA

LEGEND:
HP

MCA

COMPRESSOR
(each)

* *
15 */20*
25 */30*
35 */40*

10 /12
10
12.2
(ALT.)

MCA

MOCP

151.8

200

FLA

25.1/30.1 151.8/151.8 200/200


37.7/50.2 151.8/151.8 200/200
62.8/75.3 151.8/151.8 200/200
87.9/100.4 151.8/151.8 200/200

155.9

200

25.1/30.1 155.9/155.9 200/200


37.7/50.2 155.9/155.9 200/200
62.8/75.3 155.9/155.9 200/200
87.9/100.4 155.9/156.1 200/200

83.9

110

15.2/18.2

83.9/83.9

110/110

22.8/30.4

83.9/83.9

110/110

38/45.6

83.9/83.9

110/110

53.2/60.8

84/94

110/110

85.6

110

15.2/18.2

85.6/85.6

110/110

22.8/30.4

85.6/85.6

110/110

38/45.6

85.6/85.6

110/110

53.2/60.8

86.3/95.8

110/110

71.9

12.6/15.1 71.9/71.9

90
90/90

18.8/25.1

71.9/71.9

90/90

31.4/37.7

71.9/71.9

90/90

43.9/50.2

71.9/75.5

90/90

73.9

12.6/15.1 73.9/73.9

90
90/90

18.8/25.1

73.9/73.9

90/90

31.4/37.7

73.9/73.9

90/90

43.9/50.2

73.9/78

90/90

ELECTRICAL DATA
MODEL: PY360
MODEL NUMBER

DESCRIPTION

POWER
SUPPLY
(V-Ph-Hz)

PY360

VOLTAGE
RANGE
Min.

Max.

FM
(each)
FLA

COMPRESSOR
(each)

BM

ELECTRIC
HEATER

RLA LRA HP FLA Nom. kW

* *
15*/20*
25*/30*
35*/40*

10 /12
10 24.5
(STD)

208/230-3-60

187

253

5.4

58.6 340

* *
15*/20*
25*/30*
35*/40*

10 /12
15
(ALT.)

37

* *
15*/20*
25*/30*
35*/40*

10 /12
10 15.8
(STD)

380-3-60 (4 WIRE)

342

418

2.7

35.7 196

* *
15*/20*
25*/30*
35*/40*

10 /12
15
23.1
(ALT.)

* *
15*/20*
25*/30*
35*/40*

10 /12
10 12.2
(STD)

460-3-60

414

506

2.7

28.6 173

* *
15*/20*
25*/30*
35*/40*

10 /12
15
18.5
(ALT.)

LEGEND:
HP

- Horse Power

BM

- Blower Motor

FM

- Fan Motor (Condenser)

RLA

- Rated Load Amps

FLA

- Full Load Amps

LRA

- Locked Rotor Amps

MCA

- Minimum Circuit Amps

MOCP - Maximum Over Current Protection

*Combination of heater

modules

22

MCA

MOCP

167.2

220

FLA

25.1/30.1 167.2/167.2 220/220


37.7/50.2 167.2/167.2 220/220
62.8/75.3 167.2/167.2 220/220
87.9/100.4 167.2/167.2 220/220

179.7

230

25.1/30.1 179.7/179.7 230/230


37.7/50.2 179.7/179.7 230/230
62.8/75.3 179.7/179.7 230/230
87.9/100.4 179.7/179.7 230/230

101.6

130

15.2/18.2 101.6/101.6 130/130


22.8/30.4 101.6/101.6 130/130
38/45.6

101.6/101.6 130/130

53.2/60.8 101.6/101.6 130/130

108.9

140

15.2/18.2 108.9/108.9 140/140


22.8/30.4 108.9/108.9 140/140
38/45.6

108.9/108.9 140/140

53.2/60.8 108.9/108.9 140/140


82

100

12.6/15.1

82/82

100/100

18.8/25.1

82/82

100/100

31.4/37.7

82/82

100/100

43.9/50.2

82/82

100/100

88.3

12.6/15.1 88.3/88.3

110
110/110

18.8/25.1

88.3/88.3

110/110

31.4/37.7

88.3/88.3

110/110

43.9/50.2

88.3/88.3

110/110

FAN PERFORMANCE DATA


(DIRECT DRIVE MOTOR)
Model No.: PY036
EXTERNAL STATIC PRESSURE (inch wg.)

BLOWER MOTOR
SPEED
0.1

0.2

0.3

0.4

0.5

0.6

CFM

1200

1150

1100

1038

992

946

BHP

0.438

0.433

0.429

0.426

0.417

0.409

CFM

1030

970

894

870

834

798

BHP

0.355

0.350

0.347

0.344

0.340

0.336

CFM

910

840

799

760

704

648

BHP

0.296

0.293

0.290

0.286

0.283

0.279

HIGH

MEDIUM

LOW

Model No.: PY048


EXTERNAL STATIC PRESSURE (inch wg.)

BLOWER MOTOR
SPEED
0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

CFM

1918

1875

1800

1733

1671

1609

1521

1433

1323

1212

BHP

0.94

0.92

0.88

0.83

0.80

0.76

0.72

0.68

0.64

0.59

CFM

1733

1650

1620

1600

1538

1475

1401

1327

1240

1153

BHP

0.84

0.81

0.77

0.74

0.76

0.78

0.69

0.60

0.56

0.52

CFM

1586

1500

1485

1450

1399

1347

1280

1222

1134

1046

BHP

0.77

0.73

0.69

0.66

0.63

0.60

0.57

0.54

0.50

0.46

HIGH

MEDIUM

LOW

Model No.: PY060


EXTERNAL STATIC PRESSURE (inch wg.)

BLOWER MOTOR
SPEED
0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

CFM

2030

2000

1902

1850

1750

1676

1592

1507

1398

1289

BHP

1.08

1.07

1.03

0.99

0.95

0.92

0.88

0.85

0.81

0.77

CFM

1918

1875

1800

1733

1671

1609

1521

1433

1323

1212

BHP

0.94

0.92

0.88

0.83

0.80

0.76

0.72

0.68

0.64

0.59

CFM

1733

1650

1620

1600

1538

1475

1401

1327

1240

1153

BHP

0.84

0.81

0.77

0.74

0.76

0.78

0.69

0.60

0.56

0.52

HIGH

MEDIUM

LOW

NOTES: 1. Values include losses for dry coil, 1" thick filters & unit casing.
2. Direct drive motors have single speed connection only. Factory set at medium speed.

23

FAN PERFORMANCE DATA


Model No.: PY075
External Static Pressure (inch wg.)

Airflow,
CFM (L/S)

0.2

0.4

RPM

BHP

1800 (849)

759*

2000 (944)

0.6

0.8

1.0

1.2

1.4

1.6

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

0.43*

862

0.54

937

0.66

1015

0.78

1088

0.92

1156

1.06

1235

0.98

1270

1.20

805*

0.54*

882

0.65

963

0.78

1039

0.91

1109

1.05

1176

1.19

1242

1.35

1299

1.51

2200 (1038)

845

0.66

911

0.78

989

0.91

1062

1.05

1131

1.19

1196

1.34

1258

1.50

1317

1.67

2400 (1133)

861

0.79

941

0.93

1016

1.06

1080

1.21

1153

1.36

1216

1.52

1277

1.68

1334

1.85

2600 (1227)

895

0.95

971

1.09

1043

1.23

1111

1.38

1175

1.54

1237

1.71

1296

1.87

2800 (1321)

928

1.12

1001

1.27

1070

1.42

1135

1.58

1198

1.75

1258

1.92

3000 (1416)

962

1.31

1044

1.47

1098

1.63

1161

1.80

3200 (1510)

996

1.42

1072

1.69

1125

1.86

II

NOTES:1. Values include losses for filters, unit casing and wet coils.
2. Standard 1.5 HP motor to be used for the unshaded portion.
3. Alt. 2 HP motor to be used for the shaded portion.
4. Bordered regions indicate alternative drives I & II.

* For bold figures, consult your nearest Zamil representative for proper selection of drives. Drives shall be field supplied & installed.

Model No.: PY090


Airflow,
CFM (L/S)
2400 (1133)
2600 (1227)
2800 (1321)
3000 (1416)
3200 (1510)
3400 (1605)
3600 (1699)
3800 (1793)

0.2
RPM BHP

0.4
RPM BHP

External Static Pressure (inch wg.)


0.6
0.8
1.0
1.2
RPM BHP RPM BHP RPM BHP RPM BHP

766*
815*
844
874
904
933
963
993

852
877
902
927
953
980
1007
1034

933
954
976
998
1021
1044
1069
1093

0.65*
0.78*
0.93
1.09
1.27
1.46
1.68
1.92

0.78
0.92
1.07
1.24
1.43
1.63
1.86
2.10

0.91
1.05
1.22
1.39
1.59
1.80
2.04
2.29

1008
1026
1046
1065
1086
1107
1129
1152

1.05
1.20
1.37
1.55
1.76
1.98
2.22
2.48

1079
1095
1112
1130
1153
1167
1187
1208

1.19
1.35
1.52
1.72
1.93
2.16
2.41
2.68

1146
1161
1176
1192
1209
1226
1244
1263

1.34
1.51
1.69
1.88
2.10
2.34
2.60
2.87

1.4
1.6
RPM BHP RPM BHP

1.8
2.0
RPM BHP RPM BHP

1210
1223
1237
1251
1267
1282
1299

1329
1340
1352
1364
1377
1390

1.50
1.67
1.85
2.06
2.28
2.53
2.79

1271
1283
1296
1309
1323
1337

1.66
1.83
2.03
2.24
2.47
2.72

1.83
2.01
2.21
2.42
2.66
2.91

1384
1395
1406
1417
1429

2.00
2.19
2.39
2.61
2.85

II

NOTES:1. Values include losses for filters, unit casing and wet coils.
2. Standard 2 HP motor to be used for the unshaded portion.
3. Alt. 3 HP motor to be used for the shaded portion.
4. Bordered regions indicate alternative drives I & II.

* For bold figures, consult your nearest Zamil representative for proper selection of drives. Drives shall be field supplied & installed.

Model No.: PY100


Airflow,
CFM (L/S)

0.2
RPM BHP

0.4
RPM BHP

External Static Pressure (inch wg.)


0.6
0.8
1.0
1.2
RPM BHP RPM BHP RPM BHP RPM BHP

2700 (1274
2800 (1321)
3000 (1416)
3200 (1510)
3400 (1605
3600 (1699)
3800 (1793)
4000 (1888)

665*
674*
690*
702*
716
732
766
784

0.68*
0.74*
0.78*
0.87*
0.98
1.09
1.28
1.42

723
725
737
744
756
766
793
820

0.78
0.82
0.93
1.01
1.09
1.23
1.40
1.58

785
788
800
804
815
823
852
870

0.93
0.96
1.08
1.18
1.31
1.40
1.60
1.75

848
849
854
857
864
876
904
918

1.07
1.12
1.17
1.23
1.45
1.57
1.78
1.93

905
906
910
913
919
927
954
964

1.24
1.29
1.39
1.49
1.61
1.75
1.94
2.13

4100(1935)

789

1.48

829

1.67

895

1.83

927

2.03

972

2.23

961
962
964
966
970
974
997

1.39
1.43
1.54
1.65
1.80
1.90
2.13

1.4
1.6
RPM BHP RPM BHP

1.8
2.0
RPM BHP RPM BHP

1012
1013
1015
1017
1019
1021

1114
1115
1117
1119

1.54
1.59
1.71
1.83
1.96
2.10

1064
1065
1067
1069
1071

1.73
1.76
1.89
2.00
2.15

NOTES:1. Values include losses for filters, unit casing and wet coils.
2. Standard 2 HP motor to be used for the unshaded portion.
3. Alt. 3 HP motor to be used for the shaded portion.
4. Bordered regions indicate alternative drives I & II.

* For bold figures, consult your nearest Zamil representative for proper selection of drives. Drives shall be field supplied & installed.

24

1.90
1.94
2.11
2.23

1160
1161

II

2.05
2.11

FAN PERFORMANCE DATA


Model No.: PY120
Airflow,
CFM (L/S)

0.2
RPM BHP

0.4
RPM BHP
753
768
782
797
812
827
843

1.01
1.13
1.26
1.39
1.54
1.70
1.87

External Static Pressure (inch wg.)


0.6
0.8
1.0
1.2
RPM BHP RPM BHP RPM BHP RPM BHP
822
834
846
859
872
885
899

1.22
1.35
1.48
1.63
1.78
1.95
2.12

3200 (1510)
3400 (1605)
3600 (1699)
3800 (1793)
4000 (1888)
4200 (1982)
4400 (2076)

680* 0.813*
697* 0.924*
716* 1.042*
733 1.17
749 1.31
767 1.46
785 1.62

4600 (2170)

802

1.80

859

2.05

913

2.31

4800 (2265)

820

1.99

875

2.24

927

2.51

886
897
907
918
929
941
953

1.44
1.57
1.72
1.87
2.03
2.21
2.39

938
946
955
965
970
985
995

1.56
1.71
1.86
2.02
2.19
2.37
2.56

966

2.59

1006

2.77

970

2.80

1006
1013
1021
1029
1037
1046
1056

1.69
1.85
2.01
2.18
2.36
2.55
2.75

1.4
1.6
RPM BHP RPM BHP

1.8
2.0
RPM BHP RPM BHP

1061
1068
1074
1081
1088
1096

1165
1170
1174

1.93
2.09
2.26
2.45
2.63
2.83

1114
1120
1125
1131

2.17
2.34
2.53
2.72

2.41
2.60
2.79

II

NOTES:1. Values include losses for filters, unit casing and wet coils.
2. Standard 3 HP motor to be used.
3. Bordered regions indicate alternative drives I & II.

* For bold figures, consult your nearest Zamil representative for proper selection of drives. Drives shall be field supplied & installed.

Model No.: PY150


Airflow,
CFM (L/S)

0.2
RPM BHP

0.4
RPM BHP

3800 (1793)
4000 (1888)
4200 (1982)
4400 (2076)
4600 (2170)
4800 (2265)
5000 (2360)

733*
749*
767*
785*
802*
820
838

1.17*
1.31*
1.46*
1.62*
1.8*
1.99
2.18

797*
812*
827
843
859
875
891

1.39*
1.54*
1.70
1.87
2.05
2.24
2.45

5200 (2454)

856

2.40

907

5400 (2548)

874

2.62

925

5600 (2643)

898

2.86

5800 (2737)

944

3.12

External Static Pressure (inch wg.)


0.6
0.8
1.0
1.2
RPM BHP RPM BHP RPM BHP RPM BHP

1.4
1.6
RPM BHP RPM BHP

1.8
2.0
RPM BHP RPM BHP
1180

859
872
885
899
913
927
942

1.63
1.78
1.95
2.12
2.31
2.51
2.73

918
929
941
953
966
981
991

1.87
2.03
2.21
2.39
2.59
2.80
3.02

965
974
985
995
1006
1018
1030

2.01
2.19
2.37
2.57
2.77
2.99
3.21

1029
1037
1041
1056
1066
1076
1087

2.18
2.36
2.55
2.75
2.96
3.19
3.42

1081
1088
1096
1105
1113
1123
1132

2.45
2.63
2.83
3.04
3.26
3.49
3.74

2.67

957

2.95

1005

3.25

1042

3.46

1098

3.67

1142

3.99

2.90

972

3.19

1019

3.50

1054

3.71

1109

3.93

1153

4.26

944

3.15

987

3.45

1032

3.76

1067

3.98

1121

4.21

1163

4.54

956

3.41

1002

3.72

1047

4.03

1080

3.26

1133

4.50

1131
1137
1145
1152
1160
1168
1177

2.72
2.91
3.12
3.34
3.57
3.80
4.06

2.99

II

NOTES:1. Values include losses for filters, unit casing and wet coils.
2. Standard 3 HP motor to be used for the unshaded portion.
3. Alt. 5 HP motor to be used for the shaded portion.
4. Bordered regions indicate alternative drives I & II.

* For bold figures, consult your nearest Zamil representative for proper selection of drives. Drives shall be field supplied & installed.

Model No.: PY180


Airflow,
CFM (L/S)
4800 (2265)
5000 (2360
5200 (2454)
5400 (2548)
5600 (2643)
5800 (2737)
6000 (2832)
6200 (2926)
6400 (3020)
6600 (3115)
6800 (3209)
7000 (3303)
7200 (3398)

0.2
RPM BHP

0.4
RPM BHP

652*
668*
683*
699*
719
731
746
762
778
794
809
825
861

711*
725
738
752
766
781
795
809
824
838
870
884
897

1.47*
1.62*
1.80*
1.97*
2.16
2.36
2.58
2.80
3.05
3.30
3.40
3.70
4.00

1.69*
1.85
2.03
2.21
2.41
2.61
2.84
3.07
3.32
3.58
3.70
4.00
4.30

External Static Pressure (inch wg.)


0.6
0.8
1.0
1.2
1.4
1.6
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP

728
740
752
764
776
797
811
830
843
857
878
890
914

1.93
2.10
2.28
2.47
2.67
2.78
2.91
3.15
3.45
3.67
4.00
4.30
4.60

763
773
783
807
818
830
854
865
877
887
902
911
928

2.18
2.26
2.34
2.54
2.74
2.96
3.19
3.36
3.65
3.97
4.30
4.60
4.90

826
844
853
858
872
882
893
904
914
927
952
964
976

2.25
2.43
2.62
2.80
3.03
3.26
3.50
3.75
3.85
4.08
4.60
4.90
5.30

880
888
896
904
913
926
939
948
960
968
971
990
1001

2.53
2.62
2.91
3.12
3.13
3.57
3.61
3.86
4.09
4.41
5.00
5.30
5.60

928
933
940
948
955
963
972
981
1013
1030
1041
1048
1060

2.57
2.77
3.11
3.18
3.45
3.66
3.89
4.19
4.46
4.71
5.30
5.60
5.90

II

970
975
981
1008
1017
1024
1031
1039
1047
1056
1065
1074
1083

2.92
3.12
3.32
3.54
3.77
4.01
4.26
4.53
4.81
5.10
5.70
6.00
6.30

NOTES:1. Values include losses for filters, unit casing and wet coils.
2. Standard 5 HP motor to be used for the unshaded portion.
3. Alt. 7.5 HP motor to be used for the shaded portion.
4. Bordered regions indicate alternative drives I & II.

* For bold figures, consult your nearest Zamil representative for proper selection of drives. Drives shall be field supplied & installed.
25

1.8
RPM BHP

2.0
RPM BHP

1032
1037
1042
1047
1053
1059
1066
1073
1077
1088
1098
1102
1113

1075
1077
1083
1085
1092
1096
1102
1110
1115
1122*
1129*
1137*
1145*

3.22
3.43
3.64
3.87
4.11
4.35
4.61
4.88
5.16
5.46
6.00
6.30
6.70

3.54
3.75
3.97
4.20
4.44
4.70
4.96
5.24
5.52
5.83*
6.40*
6.70*
7.10*

FAN PERFORMANCE DATA


Model No.: PY210
Airflow,
CFM (L/S)
5800 (2737)
6000 (2832)
6200 (2926)
6400 (3020)
6600 (3115)
6800 (3209)
7000 (3303)
7200 (3398)
7400 (3492)
7600 (3587)
7800 (3681)
8000 (3775)
8200 (3870)

0.2
RPM BHP
709*
725*
741*
757
773
808
815
835
855
881
895
903
918

2.21*
2.42*
2.65*
2.90
3.16
3.23
3.56
4.00
4.12
4.40
4.70
5.10
5.45

0.4
RPM BHP
759
774
788
802
824
846
856
872
882
907
912
927
945

2.46
2.68
2.90
3.17
3.42
3.56
3.95
4.20
4.50
4.72
5.00
5.40
5.72

External Static Pressure (inch wg.)


0.6
0.8
1.0
1.2
1.4
1.6
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP

805
826
839
849
875
892
911
925
938
954
968
988
1002

2.93
3.00
3.35
3.60
3.80
4.11
4.40
4.70
5.01
5.25
5.50
5.90
6.32

845
857
870
882
898
910
928
935
959
974
987
1001
1016

3.01
3.30
3.60
3.90
4.13
4.45
4.73
5.00
5.30
5.54
5.93
6.25
6.70

892
901
912
925
945
961
972
978
996
1008
1027
1054
1067

3.30
3.60
3.90
4.30
4.50
4.80
5.00
5.35
5.63
5.90
6.30
6.65
7.12

927
935
946
956
966
977
990
1015
1032
1046
1056
1067

3.62
3.80
4.20
4.60
4.80
5.11
5.34
5.65
5.93
6.30
6.74
7.08

973
982
998
1028
1037
1047
1058
1064
1079
1086
1099

3.80
4.20
4.50
4.90
5.10
5.41
5.69
5.98
6.37
6.70
7.11

1031
1039
1047
1058
1064
1074
1082
1087
1095
1099

4.12
4.60
4.85
5.20
5.42
5.75
6.05
6.30
6.75
7.11

1.8
RPM BHP

2.0
RPM BHP

1067
1074
1081
1088
1091
1106
1111
1120*
1125*

1103
1109
1111
1122*
1129*
1137*
1145*
1150*

4.46
4.92
5.19
5.50
5.78
6.16
6.42
6.8*
7.12*

4.81
5.28
5.55
5.85*
6.15*
6.47*
6.81*
7.23*

II

NOTES:1. Values include losses for filters, unit casing and wet coils.
2. Standard 5 HP motor to be used for the unshaded portion.
3. Alt. 7.5 HP motor to be used for the shaded portion.
4. Bordered regions indicate alternative drives I & II.

* For bold figures, consult your nearest Zamil representative for proper selection of drives. Drives shall be field supplied & installed.

Model No.: PY240


Airflow,
CFM (L/S)
6000 (2832)
6200 (2926
6400 (3020)
6600 (3115)
6800 (3209)
7000 (3303)
7200 (3398)
7400 (3492)
7600 (3587)
7800 (3681)
8000 (3775
8200 (3870)
8400 (3964)
8600 (4058)
8800 (4152)
9000 (4247)

0.2
RPM BHP

0.4
RPM BHP

577*
586*
595*
605*
614*
623*
653*
642*
651*
660*
670*
679*
689
698
707
716

586*
642*
649*
657*
665*
673*
681*
689
697
705
714
707
730
739
747
756

2.03*
2.15*
2.27*
2.39*
2.52*
2.66*
2.80*
2.95*
3.10*
3.26*
4.43*
3.61*
3.79
3.98
4.17
4.38

2.13*
2.25*
2.24*
2.51*
2.64*
2.78*
2.94*
3.09
3.26
3.43
3.60
3.65
3.98
4.17
4.38
4.59

External Static Pressure (inch wg.)


0.6
0.8
1.0
1.2
RPM BHP RPM BHP RPM BHP RPM BHP
689
695
701
708
715
721
728
735
743
750
757
764
772
780
787
795

2.24
2.36
2.50
2.64
2.78
2.93
3.09
3.25
3.43
3.60
3.79
3.97
4.17
4.38
4.59
4.81

741
746
751
757
763
768
774
780
787
793
800
806
813
820
826
833

2.36
2.49
2.63
2.78
2.93
3.09
3.25
3.43
3.61
3.79
3.98
4.17
4.38
4.59
4.81
5.04

790
795
799
804
809
814
819
824
828
835
841
847
853
859
865
871

2.68
2.83
2.98
3.13
3.29
3.46
3.63
3.81
3.97
4.18
4.38
4.59
4.80
5.02
5.24
5.48

837
841
845
850
854
858
862
867
872
875
882
887
892
898
903
909

3.02
3.17
3.33
3.49
3.66
3.83
4.01
4.20
4.39
4.59
4.79
5.01
5.23
5.45
5.68
5.93

1.4
1.6
RPM BHP RPM BHP
882
886
889
893
897
900
904
908
913
917
921
926
930
935
940
945

3.12
3.28
3.44
3.61
3.79
3.97
4.15
4.35
4.55
4.75
4.97
5.18
5.41
5.64
5.88
6.13

926
928
931
935
938
941
945
948
952
956
960
964
968
972
977
981

3.48
3.64
3.81
3.99
4.17
4.36
4.55
4.75
4.96
5.17
5.40
5.62
5.86
6.10
6.34
6.60

NOTES:1. Values include losses for filters, unit casing and wet coils.
2. Standard 7.5 HP motor to be used.
3. Bordered regions indicate alternative drives I & II.

* For bold figures, consult your nearest Zamil representative for proper selection of drives. Drives shall be field supplied & installed.

26

1.8
2.0
RPM BHP RPM BHP
967
969
972
975
978
981
984
987
990
994
997
1001
1004
1008
1012

3.84
4.01
4.19
4.38
4.57
4.76
4.96
5.17
5.38
5.60
5.83
6.07
6.31
6.56
6.81

1006
1009
1011
1014
1016
1019
1022
1024
1027
1030
1034
1037
1040
1044

II

4.22
4.39
4.58
4.77
4.97
5.17
5.38
5.59
5.81
6.04
6.28
6.52
6.77
7.02

FAN PERFORMANCE DATA


Model No.: PY300
Airflow,
CFM (L/S)
8000 (3775
8200 (3870)
8400 (3964)
8600 (4058)
8800 (4152)
9000 (4247)
9200 (4341)
9400 (4436)
9600 (4530)
9800 (4624)
10000 (4719)
10200 (4813)
10400 (4907)
10600 (5002)
10800 (5096)
11000 (5191)
11200 (5286)

0.2
RPM BHP
670*
679*
689
698
707
716
726
735
744
754
763
777
782
792
801
810
820

3.43*
3.61*
3.79
3.98
4.17
4.38
4.42
4.61
4.84
5.07
5.31
5.57
5.83
6.09
6.37
6.65
6.95

0.4
RPM BHP
714
707
730
739
747
756
764
773
781
790
799
808
817
825
834
843
852

3.60
3.65
3.98
4.17
4.38
4.59
4.71
4.83
5.21
5.31
5.56
5.82
6.09
6.36
6.65
6.94
7.24

External Static Pressure (inch wg.)


0.6
0.8
1.0
1.2
RPM BHP RPM BHP RPM BHP RPM BHP
757
764
772
780
787
795
803
810
818
826
834
842
850
859
867
875
883

3.79
3.97
4.17
4.38
4.59
4.81
4.92
5.07
5.31
5.56
6.22
6.48
6.76
7.04
7.33
7.63
7.94

800
806
813
820
826
833
840
848
855
862
869
874
884
892
900
907
915

3.98
4.17
4.38
4.59
4.81
5.04
5.27
5.51
5.76
6.02
6.38
6.66
6.94
7.23
7.53
7.84
8.15

841
847
853
859
865
871
875
884
891
897
904
911
918
925
932
939
946

4.38
4.59
4.80
5.02
5.24
5.48
5.72
5.97
6.22
6.49
6.76
7.04
7.33
7.63
7.93
8.25
8.57

882
887
892
898
903
909
914
920
926
932
938
945
951
958
964
971
978

4.79
5.01
5.23
5.45
5.68
5.93
6.17
6.43
6.69
6.97
7.25
7.53
7.83
8.13
8.45
8.77
9.10

1.4
1.6
RPM BHP RPM BHP

1.8
2.0
RPM BHP RPM BHP

921
926
930
935
940
945
950
956
961
967
972
978
984
990
996
1002

997
1001
1004
1008
1012
1016
1021
1025
1029
1034
1039
1044
1049

4.97
5.18
5.41
5.64
5.88
6.13
6.39
6.65
6.92
7.20
7.49
7.78
8.13
8.40
8.72
9.05

960
964
968
972
977
981
986
991
995
1001
1006
1011
1016
1022
1028

5.40
5.62
5.86
6.10
6.34
6.60
6.86
7.13
7.41
7.70
7.99
8.29
8.60
8.92
9.25

5.83
6.07
6.31
6.56
6.81
7.07
7.34
7.62
7.90
8.20
8.50
8.81
9.13

1034
1037
1040
1044
1047
1051
1055
1059
1063
1067
1071
1076

6.28
6.52
6.77
7.02
7.28
7.55
7.83
8.12
8.41
8.71
9.02
9.33

II

NOTES:1. Values include losses for filters, unit casing and wet coils.
2. Standard 7.5 HP motor to be used for the unshaded portion.
3. Alt. 10 HP motor to be used for the shaded portion.
4. Bordered regions indicate alternative drives I & II.

* For bold figures, consult your nearest Zamil representative for proper selection of drives. Drives shall be field supplied & installed.

Model No.: PY340


Airflow,
CFM (L/S)
9000 (4247)
9200 (4341)
9400 (4436)
9600 (4530)
9800 (4624)
10000 (4719)
10200 (4813)
10400 (4907)
10600 (5002)
10800 (5096)
11000 (5191)
11200 (5286)
11400 (5380)
11600 (5474)
11800 (5569)
12000 (5663)

0.2
RPM BHP
716
726
735
744
754
763
777
782
792
801
810
820
829
839
848
858

3.38
4.59
4.61
4.84
5.07
5.31
5.57
5.83
6.09
6.37
6.65
6.95
7.25
7.57
7.91
8.22

0.4
RPM BHP
756
764
773
781
790
799
808
817
825
834
843
852
861
870
875
887

4.59
4.81
4.83
5.07
5.31
5.56
5.82
6.29
6.56
6.65
6.94
7.24
7.55
7.87
8.20
8.54

External Static Pressure (inch wg.)


0.6
0.8
1.0
1.2
RPM BHP RPM BHP RPM BHP RPM BHP
795
803
810
818
826
834
842
850
859
867
875
883
892
900
909
915

4.81
5.03
5.07
5.31
5.56
6.22
6.48
6.79
7.04
7.33
7.63
7.94
8.26
8.59
8.93
9.27

833
840
848
855
862
869
874
884
892
900
907
915
923
931
939
947

5.04
5.27
5.51
5.76
6.02
6.38
6.66
6.94
7.23
7.53
7.84
8.15
8.48
8.82
9.16
9.51

871
875
884
891
897
904
911
918
925
932
939
946
954
961
969

5.48
5.72
5.97
6.22
6.49
6.76
7.04
7.33
7.63
7.93
8.25
8.57
8.91
9.63
9.60

909
914
920
926
932
938
945
951
958
964
971
978
984

5.93
6.17
6.43
6.69
6.97
7.25
7.53
7.83
8.13
8.45
8.77
9.10
9.44

1.4
1.6
RPM BHP RPM BHP

1.8
2.0
RPM BHP RPM BHP

945
950
956
961
967
972
978
984
990
996
1002
1009

1016
1021
1025
1029
1034
1039
1044
1049

6.13
6.39
6.65
6.92
7.20
7.49
7.78
8.13
8.40
8.72
9.05
9.39

981
986
991
995
1001
1006
1011
1016
1022
1028

6.60
6.86
7.13
7.41
7.70
7.99
8.29
8.60
8.92
9.25

NOTES:1. Values include losses for filters, unit casing and wet coils.
2. Standard 7.5 HP motor to be used for the unshaded portion.
3. Alt. 10 HP motor to be used for the shaded portion.
4. Bordered regions indicate alternative drives I & II.

* For bold figures, consult your nearest Zamil representative for proper selection of drives. Drives shall be field supplied & installed.

27

II

7.07
7.34
7.62
7.90
8.20
8.50
8.81
9.13

1051
1055
1059
1063
1067
1071
1076

7.55
7.83
8.12
8.41
8.71
9.02
9.33

FAN PERFORMANCE DATA


Model No.: PY360
Airflow,
CFM (L/S)
9600 (4530)
9800 (4624)
10000 (4719)
10200 (4813)
10400 (4907)
10600 (5002)
10800 (5096)
11000 (5191)
11200 (5286)
11400 (5380)
11600 (5474)
11800 (5569)
12000 (5663)
12200 (5757)
12400 (5852)
12500 (5899)

0.2
RPM BHP

0.4
RPM BHP

645*
655*
665*
675*
685*
695
705
715
725
735
745
755
765
775
785
795

675*
685*
695
705
715
725
735
745
755
765
775
785
795
805
815
825

5.40*
5.60*
5.80*
6.00*
6.20*
6.40
6.60
6.80
7.00
7.20
7.40
7.60
7.80
8.00
8.20
8.40

5.70*
5.90*
6.10
6.30
6.50
6.70
6.90
7.10
7.30
7.50
7.70
7.90
8.10
8.30
8.50
8.70

External Static Pressure (inch wg.)


0.6
0.8
1.0
1.2
RPM BHP RPM BHP RPM BHP RPM BHP
705
715
725
735
745
755
765
775
785
795
805
815
825
835
845
855

6.10
6.30
6.50
6.70
6.90
7.10
7.30
7.50
7.70
7.90
8.10
8.30
8.50
8.70
8.90
9.10

730
740
750
760
770
780
790
800
810
820
830
840
850
860
870
880

6.50
6.70
6.90
7.10
7.30
7.50
7.70
7.90
8.10
8.30
8.50
8.70
8.90
9.10
9.30
9.50

760
770
780
790
800
810
820
830
840
850
860
870
880
890
900
910

7.00
7.20
7.40
7.60
7.80
8.00
8.20
8.40
8.60
8.80
9.00
9.20
9.40
9.60
9.80
10.00

790
800
810
820
830
840
850
860
870
880
890
900
910
920
930
940

7.40
7.60
7.80
8.00
8.20
8.40
8.60
8.80
9.00
9.20
9.40
9.60
9.80
10.00
10.20
10.40

1.4
1.6
RPM BHP RPM BHP
825
835
845
855
865
875
885
895
905
915
925
935
945
955
965
975

7.90 850
8.10 860
8.30 870
8.50 880
8.70 890
8.90 900
9.10 910
9.30 920
9.50 930
9.70 940
9.90 950
10.10 960
10.30 970
10.50 980
10.70 990
10.90 1000

8.40
8.60
8.80
9.00
9.20
9.40
9.60
9.80
10.00
10.20
10.40
10.60
10.80
11.00
11.20
11.40

NOTES:1. Values include losses for filters, unit casing and wet coils.
2. Standard 10 HP motor to be used for the unshaded portion.
3. Alt. 15 HP motor to be used for the shaded portion.
4. Bordered regions indicate alternative drives I & II.

* For bold figures, consult your nearest Zamil representative for proper selection of drives. Drives shall be field supplied & installed.

28

1.8
2.0
RPM BHP RPM BHP
880
890
900
910
920
930
940
950
960
970
980
990
1000
1010
1020
1030

8.80
9.00
9.20
9.40
9.60
9.80
10.00
10.20
10.40
10.60
10.80
11.00
11.20
11.40
11.60
11.80

II

910
920
930
940
950
960
970
980
990
1000
1010
1020
1030
1040
1050
1060

9.40
9.60
9.80
10.00
10.20
10.40
10.60
10.80
11.00
11.20
11.40
11.60
11.80
12.00
12.20
12.40

SOUND LEVEL DATA


To obtain Sound Pressure Level measured 5 ft. (1.6 m) directly opposite the center of blower inlet:
1. From performance table at operating conditions, find BHP, RPM & Static Efficiency (SE).
SE= (CFM x TSP)/6362 x BHP (see step 4 & table below).
2. Read dBA level from respective graph at operating BHP & SE(%).
3. Knowing RPM, select proper row from sound power factor table and add dBA level to each values in the row to obtain
Sound Power Level (dB re 10-12 watts).
4. Calculate TSP (Total Static Pressure) as follows:
TSP = ISP + ESP
ESP (External Static Pressure) from Job Specification.
ISP (Internal Static Pressure) Calculate from table below.
FACE VELOCITY

INTERNAL STATIC PRESSURE (inch wg.)

(FPM)
2 ROW

3 ROW

4 ROW

200

0.42

0.44

0.47

300

0.67

0.73

0.78

400

0.88

0.95

1.05

450

1.02

1.13

1.23

500

1.16

1.29

1.49

NOTE:
Pressure drop across filter, coil and casing are included in ISP.

29

SOUND LEVEL DATA


MODELS: PY036 - PY060

SOUND POWER FACTOR TABLE


VALUES GIVE TO SOUND POWER
Octave Band
Center Frequency Hz

63

125

250

500

1000

2000

4000

8000

493-887 RPM

7.5

+ 0.5

+ 7.5

+ 10.5

+ 5.5

+2

6.5

887-1750 RPM

+ 0.5

+7

+7

+8

+ 1.5

1.5

6.5

1750-2500 RPM

+ 0.5

+7

+7

+5

+ 4.5

1.5

6.5

To obtain Sound Pressure Level measured 5 ft. (1.6 m) directly opposite the center of blower inlet:
1. From performance table at operating conditions, find BHP, RPM & Static Efficiency (SE).
SE= (CFM x TSP)/6362 x BHP
2. Read dBA level from above graph at operating BHP & SE(%).
3. Knowing RPM, select proper row from above table and add dBA level to each values in the row to obtain Sound Power
Level (dB re 10-12 watts).

30

SOUND LEVEL DATA


MODELS: PY075 - PY090

SOUND POWER FACTOR TABLE


VALUES GIVE TO SOUND POWER
Octave Band
Center Frequency Hz

63

125

250

500

1000

2000

4000

8000

251-495 RPM

+2

+ 11.5

+8

+ 5.5

+2

6.5

495-990 RPM

6.5

+ 1.5

+8

+ 10.5

+5

+ 1.5

1.5

990-1953 RPM

+ 1.5

+8

+7

+8

+ 1.5

7.5

1953-2050 RPM

+ 1.5

+8

+7

+5

+ 4.5

7.5

To obtain Sound Pressure Level measured 5 ft. (1.6 m) directly opposite the center of blower inlet:
1. From performance table at operating conditions, find BHP, RPM & Static Efficiency (SE).
SE= (CFM x TSP)/6362 x BHP
2. Read dBA level from above graph at operating BHP & SE(%).
3. Knowing RPM, select proper row from above table and add dBA level to each values in the row to obtain Sound Power
Level (dB re 10-12 watts).
31

SOUND LEVEL DATA


MODELS: PY100 - PY210

SOUND POWER FACTOR TABLE


VALUES GIVE TO SOUND POWER
Octave Band
Center Frequency Hz

63

125

250

500

1000

2000

4000

8000

211-417 RPM

4.5

+3

+ 12

+8

+5

+2

1.5

417-835 RPM

5.5

+ 2.5

+ 8.5

+ 10.5

+ 4.5

+ 1.5

7.5

835-1647 RPM

5.5

+ 2.5

+8

+7

+7

+1

2.5

7.5

To obtain Sound Pressure Level measured 5 ft. (1.6 m) directly opposite the center of blower inlet:
1. From performance table at operating conditions, find BHP, RPM & Static Efficiency (SE).
SE= (CFM x TSP)/6362 x BHP
2. Read dBA level from above graph at operating BHP & SE(%).
3. Knowing RPM, select proper row from above table and add dBA level to each values in the row to obtain Sound Power
Level (dB re 10-12 watts).
32

SOUND LEVEL DATA


MODELS: PY240 - PY340

SOUND POWER FACTOR TABLE


VALUES GIVE TO SOUND POWER
Octave Band
Center Frequency Hz

63

125

250

500

1000

2000

4000

8000

255-443 RPM

3.5

+4

+ 12.5

+8

+ 4.5

+ 1.5

7.5

443-887 RPM

+ 3.5

+9

+ 10

+4

+1

2.5

887-1750 RPM

+ 3.5

+ 8.5

+7

+7

+ 0.5

To obtain Sound Pressure Level measured 5 ft. (1.6 m) directly opposite the center of blower inlet:
1. From performance table at operating conditions, find BHP, RPM & Static Efficiency (SE).
SE= (CFM x TSP)/6362 x BHP
2. Read dBA level from above graph at operating BHP & SE(%).
3. Knowing RPM, select proper row from above table and add dBA level to each values in the row to obtain Sound Power
Level (dB re 10-12 watts).
33

SOUND LEVEL DATA


MODELS: PY360

SOUND POWER FACTOR TABLE


VALUES GIVE TO SOUND POWER
Octave Band
Center Frequency Hz

63

125

250

500

1000

2000

4000

8000

267-507 RPM

+ 4.5

+ 12.5

+ 7.5

+ 4.5

+ 1.5

7.5

507-1014 RPM

3.5

+ 3.5

+9

+ 10

+4

+ 0.5

2.5

1014-2000 RPM

+ 3.5

+ 8.5

+7

+ 6.5

+ 0.5

To obtain Sound Pressure Level measured 5 ft. (1.6 m) directly opposite to the center of blower inlet:
1. From performance table at operating conditions, find BHP, RPM & Static Efficiency (SE).
SE= (CFM x TSP)/6362 x BHP
2. Read dBA level from above graph at operating BHP & SE(%).
3. Knowing RPM, select proper row from above table and add dBA level to each values in the row to obtain Sound Power
Level (dB re 10-12 watts).
34

STATIC PRESSURE DROP (inch wg.)


MODELS: PY036 - PY060
CFM

COMPONENT

900
0.12
0.19

1 HEATER MODULE
2 HEATER MODULE

1200
0.12
0.19

1400
0.12
0.19

1600
0.13
0.20

1800
0.14
0.21

2000
0.15
0.21

MODELS: PY075 - PY090


COMPONENT
1 HEATER MODULE
2 HEATER MODULE

CFM
1600
0.11
0.18

1800
0.12
0.19

2000
0.13
0.19

2200
0.13
0.19

2400
0.14
0.20

2600
0.15
0.20

3000
0.16
0.21

3200
0.16
0.21

3400
0.17
0.22

3600
0.18
0.23

3800
0.18
0.23

MODELS: PY100 - PY150


CFM
COMPONENT
1 HEATER MODULE
2 HEATER MODULE

2600
0.04
0.06

2800
0.04
0.06

3000
0.05
0.07

3400
0.08
0.10

3800
0.10
0.12

4000
0.11
0.14

4200
0.12
0.15

4800
0.14
0.18

5200
0.16
0.20

5800
0.18
0.22

MODELS: PY180 - PY210


COMPONENT
1 HEATER MODULE
2 HEATER MODULE

CFM
4800
0.08
0.14

5200
0.08
0.14

5600
0.08
0.14

6000
0.08
0.14

6200
0.08
0.14

6800
0.09
0.16

7000
0.10
0.16

7400
0.10
0.16

7600
0.10
0.16

7800
0.11
0.17

8200
0.11
0.17

9600
0.11
0.20

10200
0.12
0.21

10800 11400 12000


0.13
0.14
0.15
0.22
0.23
0.24

MODELS: PY240 - PY360


COMPONENT
1 HEATER MODULE
2 HEATER MODULE

CFM
6000
0.05
0.14

6600
0.06
0.15

7200
0.07
0.16

7800
0.08
0.17

8400
0.09
0.18

9000
0.10
0.19

BLOWER MOTOR EFFICIENCY


MOTOR HP

0.75

1.0

1.5

2.0

3.0

5.0

7.5

10.0

EFFICIENCY (%)

0.81

0.81

0.80

0.81

0.81

0.80

0.81

0.80

NOTE: Convert BHP to watts using following formula


746 x BHP
Watts =
Motor Efficiency

35

UNIT DIMENSIONS
PY036 - PY060

24
[0.94]

NOTE:
1. All dimensions are in mm (dimensions in brackets are in inches).

36

UNIT DIMENSIONS
PY075 - PY150

COMPRESSOR / CONTROLS
ACCESS PANEL

ACCESS PANEL
FOR BLOWER & MOTOR

CONTROL COMPARTMENT
CONDENSER COIL

CONDENSATE DRAIN OUTLET


3/4" NPT

AIR IN

(OPTIONAL)
FRESH AIR OPENING/HOOD

AIR IN

SUPPLY AIR

RETURN AIR

TOP VIEW

AIR OUT

FILTER

RETURN AIR
OPENING

ACCESS
PANEL

SUPPLY AIR
OPENING

CONDENSER COIL

CONDENSER COIL
POWER SUPPLY CONN

132
[5.21]

DRAIN OUTLET

12.7 ( 0.5) MOUNTING HOLES


(2 EACH SIDE)

SIDE VIEW

FRONT VIEW

SIDE VIEW

DIMENSIONS
MODEL
A

PY075 - PY090

2080(81.89)

1162(45.75)

1034(40.71)

PY100 - PY150

2212(87.1)

1408(55.43)

1085(42.72)

1114(43.86) 308(12.15) 550(21.64) 798(31.4) 300(11.81) 251(9.87) 396(15.59) 152(5.98) 175(6.88)


1372(54)

255(10.03) 707(27.84) 790(31.1) 367(14.46) 190(7.48) 476(18.74) 150(5.91) 145(5.71)

NOTE:
1. All dimensions are in mm (dimensions in brackets are in inches).

37

24(0.94)

171(6.73) 1775(69.88)

48(1.89)

200(7.87) 1907(75.08)

UNIT DIMENSIONS
PY180 - PY360

ACCESS PANEL
FOR BLOWER & MOTOR

CONTROLS
ACCESS PANEL

CONDENSER COIL

CONTROL COMPARTMENT

CONDENSATE DRAIN OUTLET


3/4" NPT

A\IR IN

POWER INLET

(OPTIONAL)
FRESH AIR OPENING/HOOD

A\IR IN

CONDENSER COIL
AIR IN

SUPPLY AIR

RETURN AIR

TOP VIEW

AIR OUT

N
CONTROL BOX
ACCESS PANEL

FILTER
ACCESS PANEL

RETURN AIR OPENING

DRAIN OUTLET
144
[5.67]

233
[9.17]

SUPPLY AIR
OPENING

CONDENSER COIL

COMPRESSOR
ACCESS PANEL

POWER INLET
D

SIDE VIEW

G
16 x 25mm
MOUNTING SLOT (3EACH SIDE)
MOUNTING SLOT (4EACH SIDE FOR PY360)

SIDE VIEW

FRONT VIEW

DIMENSIONS
MODEL
A

R
912(35.9)

PY180 - PY210

2794(110)

1778(70) 1266(49.83)1715(67.52) 1737(68.37) 197(7.75)

817(32.17) 720(28.35) 1200(47.25)

83(3.27)

666(26.22) 194(7.64)

171(6.73)

PY240 - PY340

3048(120)

2135(84.1) 1446(56.94) 2075(81.7) 2152(84.72) 324(12.76)

915(36.02) 740(29.13) 1200(47.25)

84(3.31) 1050(41.34) 666(26.22) 289(11.38)

194(7.64)

PY360

3683(145)

938(36.93) 527(20.75)

97(3.83) 1000(39.37) 680(26.77)

372(14.65) 1125(44.29)

2184(86) 1446(56.94)2125(83.66) 2184(86)

42(1.65)

NOTE:
1. All dimensions are in mm (dimensions in brackets are in inches).

38

254(10)

CONTROLS & SEQUENCE OF OPERATION


Scroll compressors are designed to operate in single direction only. Hence, care has to be taken to ensure correct rotation
when the system is operated. Verification of correct rotation is by observing that the suction pressure drops and discharge
pressure rises when compressor run. Reverse rotation results in abnormal sound, as well as, substantially low current draw
and by interchanging power supply wire L1 & L3 will correct this problem.
The operation of the air conditioning unit is controlled by a 24VAC electronic control board.
GENERAL
The thermostat normally displays room temperature and mode of operation. The five buttons on the front of the unit allow
complete control of the thermostat. The thermostat also allows to select continuous fan operation (useful when using an air
cleaner) or have the fan come on with the compressor.
SWITCH FUNCTION
- On/Off Key
: Switch the system On or Off.
- Up Key
: To increases the set temperature.
- Down Key
: To decreases the set temperature.
- Mode Key
: Changes the mode to Fan, Cool, Heat or Auto.
- Fan Key
: Changes the Fan Operation to Auto or Continuous.
- C/F selection : By pressing Mode & UP key together, toggles between C to F or vice versa.
USER CONTROLS
Mode:
Select the desired mode of operation by pressing of the mode button:
In this mode of operation, the compressor will be in inactive state. Display shows room temperature. Fan will be running.

Fan:

Cool:
In this mode of operation, the compressor will be ON after a delay depending on the differential of room temperature & Set temperature.
In this mode of operation, Fan is ON.

Heat:

Auto:
In auto mode, thermostat provide automatic changeover from heating to cooling mode & vice versa. Thermostat
automatically switches to maintain the desired temperature.
DIP SWITCH OPTIONS AND FUNCTIONS
There are 4 small DIP (Dual in line package) switches on the back of the circuit board which must be configured by the
installer.
HOOK-UP WIRING DIAGRAM
( THERMOSTAT CONTROLLER TO PACKAGED UNIT )

DIP SWITCH SELECTION


SWITCH

ON

OFF

N. A.

N. A.

N. A.

THERMOSTAT
(ZAC P/N 80065261)

Y2

NOTE: OPTIONAL CONNECTION :


IF REMOTE TEMPERATURE SENSING
FUNCTION IS REQUIRED.

INDOOR SENSOR REMOTE SENSOR

SENSOR

PACU CONTROL PANEL

Note:
Keep DIP SWITCH 1, 2 & 3 in OFF
position only.

W1
Y1
REMOTE
SENSOR

G
24V(R)

COMPRESSOR FAULT SIGNAL


(VOLT-FREE CONTACT)

ATB

COMP 1

24V(C)
FAULT 1

( OPTIONAL CONNECTION )

FAULT 2

COMP 2
(COMMON)

LVTB
R
C
G
Y1
Y2

LEGEND:
ATB
LVTB

AUXILIARY TERMINAL BLOCK


LOW VOLTAGE TERMINAL BLOCK

39

24V ac
SUPPLY FAN CONTROL
STG1 COOLING
STG2 COOLING

W1

STG1 HEATER

W2

STG2 HEATER

W2

TYPICAL SCHEMATIC WIRING DIAGRAM


REFER TO UNIT
NAMEPLATE FOR
POWER SUPPLY

TO HVTB
L1
ATB (UVM)
JP1 1A
1

(SD)
JP2

TO NTB/HVTB
N/L2

230VAC

ATB

1B
PLEASE REFER TO FAN MOTOR CONTROL
CONNECTION FOR OLR, LOW AMBIENT AND T.O.P
FMC

HC2

SEE OPTIONAL VFC CONNECTION

AFS

28

HC1
BMC

19

(SEE NOTE 3)
OLR-1

PDS2
PDS1

(SEE NOTE 3)

TO ATB
CC2

3A

3B

4A

4B

14

29

30

41B

41A

12

CC1

THERMOSTAT / DDC CONTROLLER

LOCK2(RED)

LOCK1(RED)

PRI

SYSTEM2(ORG)

COMP1

COMP2

P1

P2

INFAN

HEATER1

HEATER2

X1

X2

OUTFAN1

OUTFAN2

LIVE

NEUTRAL

(by others)

LVTB
R

ECB

Y1

Y1

Y2

Y2

W1

W1

W2

W2

R
24Vac

BM CONTROL

STG1 COOLING

Y1

STG2 COOLING

Y2

STG1 HEATING

W1

STG2 HEATING

W2

SYSTEM1(YEL)
ON/OFF

FUSE

(ON/OFF)

ANS

P3_##

HP1

240v

(HP1)

12v-0-12v

HP2

SEC

ON

(HP2)

DIP

LP1

DIP SWITCH

(LP1)

POWER(GRN)
J_PROG

LP2
(LP2)

22A
23A

LPS1

22B
23B

LPS2

NOTE: 1. Refer to next page for legend, notes & wiring diagram for optional items.
2. Refer to unit control box (inside panel) for exact wiring diagram.

40

TYPICAL SCHEMATIC WIRING DIAGRAM


LEGEND
AR
AFS
ATB
BM
BMC
CC
CCA
CB
C. HTR
COMP
ECB
FCS
F
FL
FM
FMC
FR
HC
HPS
HVTB
HTR

AUXILIARY RELAY
AIRFLOW SWITCH
AUXILIARY TERMINAL BLOCK
BLOWER MOTOR
BLOWER MOTOR CONTACTOR
COMPRESSOR CONTACTOR
AUXILIARY CONTACT
CIRCUIT BREAKER
CRANKCASE HEATER
COMPRESSOR
ELECTRONIC CONTROL BOARD
FAN CYCLING SWITCH
FUSE
FUSE LINK
FAN MOTOR (CONDENSER)
FAN MOTOR CONTACTOR
FAULT RELAY
HEATER CONTACTOR
HIGH PRESSURE SWITCH
HIGH VOLTAGE TERMINAL BLOCK
HEATER

JP
L1
L2
L3
LPS
LUG
NTB
O/L
OHT
PDS

JUMPER
LINE 1
LINE 2
LINE 3
LOW PRESSURE SWITCH
LUG GROUND
NEUTRAL TERMINAL BLOCK
OVER LOAD
OVER HEAT THERMOSTAT
PUMP DOWN SOLENOID

SSPS

SOLID STATE PROTECTIVE SYSTEM

SD

SMOKE DETECTOR

TRANS TRANSFORMER
T'STAT THERMOSTAT
UVM

___
+

UNDER VOLTAGE MONITOR


FIELD WIRING
DISCONNECT TAB - 1/4"
SPLICE-CLOSED END
TERMINAL BLOCK OR TERMINATION POINT

NOTES
1. POWER SUPPLY, REFER TO UNIT NAMEPLATE.
2. ANY WIRE REPLACEMENT SHOULD BE OF 900C OR ITS
EQUIVALENT. USE COPPER CONDUCTOR WIRES ONLY.
3. IF PDS & HEATERS ARE FACTORY INSTALLED, PLEASE
READ BROKEN LINES AS CONTINUOUS LINES.
4. POWER MUST BE SUPPLIED TO CRANKCASE HEATER FOR
MINIMUM OF 12 HOURS PRIOR TO SYSTEM START UP.
IF POWER IS OFF 6 HOURS OR MORE, CRANKCASE
HEATER MUST BE ON FOR 12 HOURS BEFORE OPERATING THE SYSTEM.

TO ECB
TO ECB

TO ECB
OUTFAN 1
TO ECB
OUTFAN 2

FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN COMPRESSOR DAMAGE.


TO ECB
OUTFAN 1
TO ECB
OUTFAN 2

5. FUSED DISCONNECT SWITCH OR CIRCUIT BREAKER


TO BE PROVIDED BY CONSUMER WITH RATING AS
RECOMMENDED BY ZAMIL.
6. COMPRESSORS ARE PROVIDED WITH INTERNAL OVERLOAD.
7. IF COMPRESSOR IS SUPPLIED WITH SSPS, CONNECT AS
SHOWN. PLEASE ALLOW 2-3 MINUTES FOR SSPS SWITCH
TO CLOSE, BEFORE STARTING THE UNIT.
8. IF ANY CHANGE IN DIP SWITCH SETTING IS REQUIRED,
TURN OFF POWER FIRST & SET REQUIRED SETTING.
9. NEUTRAL LINE REQUIRED ON 380V-3Ph-60Hz POWER
SUPPLY ONLY.

41

PARTS LIST
MODEL NUMBER

PY036C

PY036H

PY036M

PY036F

PY048C

PY048H

PY048M

PY048F

COMPRESSOR

800-684-01 800-684-04 800-684-14 800-684-07 800-684-03 800-684-06 800-684-09 800-684-09

CONDENSER FAN MOTOR

800-544-02 800-544-02 800-544-02 800-547-32 800-544-02 800-544-02 800-544-02 800-547-32

BLOWER MOTOR

800-547-72 800-547-72 800-547-72 800-547-73 800-546-88 800-546-88 800-546-88 800-546-90

BLOWER WHEEL

800-707-34 800-707-34 800-707-34 800-707-34 800-707-34 800-707-34 800-707-34 800-707-34

CONDENSER FAN PROPELLER

800-225-02 800-225-02 800-225-02 800-225-02 800-225-02 800-225-02 800-225-02 800-225-02

CONTACTOR COMPRESSOR

800-736-07 800-095-01 800-095-01 800-095-01 800-736-22 800-736-22 800-095-01 800-095-01

CONTACTOR BLOWER MOTOR

800-736-27 800-736-27 800-736-27 800-736-27 800-736-27 800-736-27 800-736-27 800-736-27

CAPACITOR FAN MOTOR

800-353-15 800-353-15 800-353-15 800-353-15 800-353-15 800-353-15 800-353-15 800-353-15

AIRFLOW SWITCH

800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02

CAPILLARY

800-390-45 800-390-45 800-390-45 800-390-45 800-390-33 800-390-33 800-390-33 800-390-33

DISTRIBUTOR

800-198-00 800-198-00 800-198-00 800-198-00 800-191-01 800-191-01 800-191-01 800-191-01

LOW PRESSURE CONTROL

800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00

HIGH PRESSURE CONTROL

800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00

FAN GRILLE

800-625-46 800-625-46 800-625-46 800-625-46 800-625-46 800-625-46 800-625-46 800-625-46

FILTER DRIER

800-531-08 800-531-08 800-531-08 800-531-08 800-531-08 800-531-08 800-531-08 800-531-08

CONTROLLER

80065252

80065252

80065252

80065252

80065252

80065252

80065252

80065252

TRANSFORMER

80065253

80065253

80065253

80065253

80065253

80065253

80065253

80065253

MODEL NUMBER

PY060H

PY060M

PY060F

COMPRESSOR

800-672-51

800-672-52

800-672-52

CONDENSER FAN MOTOR

800-544-02

800-544-02

800-547-32

BLOWER MOTOR

800-546-88

800-546-88

800-546-90

BLOWER WHEEL

800-707-34

800-707-34

800-707-34

CONDENSER FAN PROPELLER

800-225-02

800-225-02

800-225-02

CONTACTOR COMPRESSOR

800-736-22

800-095-01

800-095-01

CONTACTOR BLOWER MOTOR

800-736-27

800-736-27

800-736-27

CAPACITOR FAN MOTOR

800-353-15

800-353-15

800-353-15

AIR FLOW SWITCH

800-005-02

800-005-02

800-005-02

CAPILLARY

800-390-37

800-390-37

800-390-37

DISTRIBUTOR

800-191-01

800-191-01

800-191-01

LOW PRESSURE CONTROL

800-557-00

800-557-00

800-557-00

HIGH PRESSURE CONTROL

800-558-00

800-558-00

800-558-00

FAN GRILLE

800-625-46

800-625-46

800-625-46

FILTER DRIER

800-531-08

800-531-08

800-531-08

CONTROLLER

80065252

80065252

80065252

TRANSFORMER

80065253

80065253

80065253

42

PARTS LIST
MODEL NUMBER

PY075H PY075M PY075F PY090H PY090M PY090F PY100H PY100M PY100F

COMPRESSOR

800-674-23 800-674-24 800-674-25 800-684-05 800-684-09 800-684-08 800-684-06 800-684-09 800-684-09

CONDENSER FAN MOTOR

800-545-58 800-545-58 800-545-63 800-545-68 800-545-68 800-545-68 800-545-68 800-545-68 800-545-68

BLOWER MOTOR

800-544-13 800-546-44 800-544-13 800-544-16 800-546-29 800-544-16 800-544-16 800-546-29 800-544-16

BLOWER WHEEL

800-707-46 800-707-46 800-707-46 800-707-46 800-707-46 800-707-46 800-707-02 800-707-02 800-707-02

CONDENSER FAN PROPELLER

800-224-23 800-224-23 800-224-23 800-224-23 800-224-23 800-224-23 800-224-23 800-224-23 800-224-23

CONTACTOR COMPRESSOR

800-736-22 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01

CONTACTOR BLOWER MOTOR

800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01

CONTACTOR COND. FAN MOTOR

N.A.

N.A.

N.A.

800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01

AIRFLOW SWITCH

800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02

EXPANSION VALVE

800-181-00 800-181-00 800-181-00 800-183-01 800-183-01 800-183-01 800-183-01 800-183-01 800-183-01

DISTRIBUTOR

800-192-03 800-192-03 800-192-03 800-198-02 800-198-02 800-198-02 800-198-02 800-198-02 800-198-02

LOW PRESSURE CONTROL

800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00

HIGH PRESSURE CONTROL

800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00

FAN GRILLE

800-625-29 800-625-29 800-625-29 800-625-29 800-625-29 800-625-29 800-625-29 800-625-29 800-625-29

FILTER DRIER

800-531-08 800-531-08 800-531-08 800-531-08 800-531-08 800-531-08 800-531-08 800-531-08 800-531-08

CONTROLLER

80065252 80065252 80065252 80065263 80065263 80065263 80065263 80065263 80065263

TRANSFORMER

80065253 80065253 80065253 80065253 80065253 80065253 80065253 80065253 80065253

MODEL NUMBER

PY120H PY120M PY120F PY150H PY150M PY150F PY180H PY180M PY180F

COMPRESSOR

800-672-51 800-672-52 800-672-52 800-674-23 800-674-24 800-674-25 800-674-76

CONDENSER FAN MOTOR

800-545-68 800-545-68 800-545-68 800-545-68 800-545-68 800-545-68 800-545-68 800-545-68 800-545-68

BLOWER MOTOR

800-544-17 800-546-92 800-544-17 800-544-17 800-546-92 800-544-17 800-544-72 800-544-64 800-544-72

BLOWER WHEEL

800-707-02 800-707-02 800-707-02 800-707-02 800-707-02 800-707-02 800-707-02 800-707-02 800-707-02

CONDENSER FAN PROPELLER

800-224-23 800-224-23 800-224-23 800-224-23 800-224-23 800-224-23 800-224-23 800-224-23 800-224-23

CONTACTOR COMPRESSOR

800-736-22 800-095-01 800-095-01 800-736-22 800-095-01 800-095-01 800-736-22 800-095-01 800-095-01

CONTACTOR BLOWER MOTOR

800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-098-55 800-098-55 800-098-55

CONTACTOR COND. FAN MOTOR

800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01

AIRFLOW SWITCH

800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02

EXPANSION VALVE

800-181-00 800-181-00 800-181-00 800-181-00 800-181-00 800-181-00 800-182-00 800-182-00 800-182-00

DISTRIBUTOR

800-192-03 800-192-03 800-192-03 800-192-03 800-192-03 800-192-03 800-196-00 800-196-00 800-196-00

LOW PRESSURE CONTROL

800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00

HIGH PRESSURE CONTROL

800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00

FAN GRILLE

800-625-29 800-625-29 800-625-29 800-625-29 800-625-29 800-625-29 800-625-74 800-625-74 800-625-74

FILTER DRIER

800-531-08 800-531-08 800-531-08 800-531-08 800-531-08 800-531-08 800-531-05 800-531-05 800-531-05

CONTROLLER

80065263 80065263 80065263 80065263 80065263 80065263 80065263 80065263 80065263

TRANSFORMER

80065253 80065253 80065253 80065253 80065253 80065253 80065253 80065253 80065253

800-674-79

800-674-80
800-674-77

800-674-81
800-674-78

800-736-48

43

PARTS LIST
MODEL NUMBER

PY210H PY210M PY210F PY240H PY240M PY240F PY300H PY300M PY300F

COMPRESSOR

800-674-65 800-674-66 800-674-67 800-674-36 800-674-37 800-674-38 800-674-17 800-674-18 800-674-19

CONDENSER FAN MOTOR

800-545-68 800-545-68 800-545-68 800-555-06 800-555-06 800-555-06 800-555-06 800-555-06 800-555-06

BLOWER MOTOR

800-544-72 800-544-64 800-544-72 800-544-73 800-544-65 800-544-73 800-544-73 800-544-65 800-544-73

BLOWER WHEEL

800-707-02 800-707-02 800-707-02 800-707-23 800-707-23 800-707-23 800-707-23 800-707-23 800-707-23

CONDENSER FAN PROPELLER

800-224-23 800-224-23 800-224-23 800-224-33 800-224-33 800-224-33 800-224-33 800-224-33 800-224-33

CONTACTOR COMPRESSOR

800-736-48 800-736-22 800-095-01 800-736-25 800-736-22 800-736-22 800-736-25 800-736-22 800-736-22

CONTACTOR BLOWER MOTOR

800-098-55 800-098-55 800-098-55 800-098-59 800-098-55 800-098-55 800-098-59 800-098-55 800-098-55

CONTACTOR COND. FAN MOTOR

800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01

AIRFLOW SWITCH

800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02

EXPANSION VALVE

800-182-00 800-182-00 800-182-00 800-185-00 800-185-00 800-185-00 800-186-00 800-186-00 800-186-00

DISTRIBUTOR

800-196-00 800-196-00 800-196-00 800-194-01 800-194-01 800-194-01 800-192-02 800-192-02 800-192-02

LOW PRESSURE CONTROL

800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00

HIGH PRESSURE CONTROL

800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00

FAN GRILLE

800-625-74 800-625-74 800-625-74 800-625-38 800-625-38 800-625-38 800-625-38 800-625-38 800-625-38

FILTER DRIER

800-531-05 800-531-05 800-531-05 800-531-05 800-531-05 800-531-05 800-531-05 800-531-05 800-531-05

CONTROLLER

80065263 80065263 80065263 80065263 80065263 80065263 80065263 80065263 80065263

TRANSFORMER

80065253 80065253 80065253 80065253 80065253 80065253 80065253 80065253 80065253

MODEL NUMBER

PY340H PY340M PY340F PY360H PY360M PY360F

COMPRESSOR

800-614-80 800-614-81 800-614-82 800-614-83 800-614-84 800-614-85

CONDENSER FAN MOTOR

800-555-06 800-555-06 800-555-06 800-555-06 800-555-06 800-555-06

BLOWER MOTOR

800-544-73 800-544-65 800-544-73 800-544-74 800-544-66 800-544-74

BLOWER WHEEL

800-707-23 800-707-23 800-707-23 800-707-94 800-707-94 800-707-94

CONDENSER FAN PROPELLER

800-224-33 800-224-33 800-224-33 800-224-33 800-224-33 800-224-33

CONTACTOR COMPRESSOR

800-098-67 800-736-48 800-736-22 800-098-68 800-736-23 800-736-48

CONTACTOR BLOWER MOTOR

800-098-59 800-098-55 800-098-55 800-098-61 800-098-57 800-098-55

CONTACTOR COND. FAN MOTOR

800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01

AIRFLOW SWITCH

800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02

EXPANSION VALVE

800-186-00 800-186-00 800-186-00 800-186-00 800-186-00 800-186-00

DISTRIBUTOR

800-192-02 800-192-02 800-192-02 800-196-16 800-196-16 800-196-16

LOW PRESSURE CONTROL

800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00

HIGH PRESSURE CONTROL

800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00

FAN GRILLE

800-625-38 800-625-38 800-625-38 800-625-38 800-625-38 800-625-38

FILTER DRIER

800-531-05 800-531-05 800-531-05 800-531-01 800-531-01 800-531-01

CONTROLLER

80065263 80065263 80065263 80065263 80065263 80065263

TRANSFORMER

80065253 80065253 80065253 80065253 80065253 80065253

44

PL-AP-PYS-10-2M-E

Anda mungkin juga menyukai