All tests & readings were done at the Laptop PC setup.

Worst-case Scenario Simulation Tests < Note: PLC-CLLI intentionally added another 4-feet of AC-cord >
Our findings: (from A&B w/o PLC-CLLI to E after adding NILI-PLC to NGE)
HomePlug-AV-200Mbps Some of the Equipment Worst-case Worst-case NILI-PLC
Conducted at CAL-LAB Sales & Service Centre, PJ +Noise-Generating Equip. w/o CLLI with CLLI added to
(Indirect NGE in red below) w/o NILI-PLC w/o NILI-PLC some NGE
Date: Feb 17 2009
Test-conditions A B C D E
If we could convert a worst-case** power-line connection-rate for PLC- 1 Central-air-conditioner ON ON ON ON ON
adapters from <30Mbps to >150Mbps, wouldn’t it prove our PLC-CLLI 2 Water-dispenser-chiller ON ON ON ON +NILI-PLC
(PLC-Enhancement series) to be extremely effective? 3 Edward’s PC ON ON ON ON +NILI-PLC
4 Server-PC ON ON ON ON +NILI-PLC
PLC-device sales would simply explode! 5 May’s work-station ON ON ON ON +NILI-PLC
Isn’t this the PLC-breakthrough everyone is waiting for? 6 Front-desk PC-station ON ON ON ON ON
Adding PLC-CLLI enhances PLC-performance with less RF-noise! 7 +PLC-adapter ON ON ON ON ON
8 +FAX-machine ON ON ON ON ON
• Less noise means higher S/N-ratio
9 Laptop PC ON ON ON ON ON
• – leading to higher throughput at lower power transmission; 10 +PLC-adapter ON ON ON ON ON
• – leading to less interference emission; 11 +Power-drill ON ON ON
• – leading to less objections & oppositions 12 +Vacuum cleaner ON ON ON
• – leading to explosion in sales
• – leading to economies of scale (lower-cost) During Transfer of a 700M- Screen Screen Screen Screen Screen
folder (many files - TCP) Print-1 Print-2 Print-3 Print-4 Print-5
• – leading to more sales & more profits & fast ROI Total Time taken (m’s”) 14’29” 7’23” 4’17” 4’20” 4’09”
Latency (ping Av-Max) - mS 21-114 11-38 7-18 7-19 6-17
Sounds unbelievable? Please come and see for yourself! Standby Tx/Rx Rate (Mbps) 21/27 27/90 97/150 101/157 160/164
Completed (at what time) 18:33 18:44 19:03 19:10 19:21
We have documented our findings, should you wish to come and verify.
Date: Feb 17 2009 Feb 17 2009
PLC-CLLI is conclusively proven to be extremely effective! Carried out by Calvin Calvin Calvin Calvin Calvin
Verified by Leong Leong Leong Leong Leong
**How did we create a worst-case network-scenario? Approved for release by Paul Paul Paul Paul Paul
To establish and simulate a worst-case power-line connection-rate (red-light),
we added 4-feet of AC-cord and then shared power supplies to a power- What conclusions can we draw from these findings?
drill, a vacuum-cleaner and a laptop PC with the PLC-adapter, at one end. • A worst-case scenario could be established successfully
At the other end was a typical PC-setup with a PLC-adaptor. See below: • Without the help of PLC-CLLI – Transfer throughput was low
Pink layout was without PLC-CLLI & Light-blue was with PLC-CLLI • NGE (Noise Generating Equipment) made the throughput worse
• When PLC-CLLI were added – throughput increased tremendously
Far apart Far apart
• With PLC-CLLI added – NGE did not have any effect on throughput
• When more NGE were powered via CAL-LAB NILI-PLC (Noise-Isolator
+Lightning Isolator), the results at column E, with the Power-drill & Vacuum-
ROUTER- ROUTER- cleaner running at the Laptop setup, both the Tx & Rx rates were 160Mbps or
SERVER SERVER
more (compared to 21/27Mbps when without PLC-CLLI at column A)
• Performance-enhancement & Noise-isolation of PLC-CLLI were effective –
ETHERNET ETHERNET
SWITCH SWITCH connection-rate improved from <30Mbps to >150Mbps!
LAPTOP
PC PC PC LAPTOP PLC-CLLI can be value-added into PLC-adapters or sold as
STATION STATION PC
VACCUUM
add-on devices. We are looking for international partners!
LCD VACCUUM LCD
CLEANER CLEANER
MONITOR MONITOR
POWER More info in www.cal-lab.com or Contact us:
FAX POWER FAX
DRILL Phone - +6012 771 8225 / +6019 2311829
MACHINE DRILL MACHINE
Email – callabhq@gmail.com / callabkl@gmail.com / callab@callab.com.my