Q.1) A salient pole syn. Motor is running with normal excitation.

If the excitation is reduced to zero: a) It becomes an induction motor. b) It becomes a reluctance motor. c) Remains a syn. Motor. d) The motor would stop. Q.2) in a synchronous generator operating at zero pf lagging, effect of armature reaction is: a) b) c) d) Magnetizing Cross magnetizing Demagnetizing Both (a) and (b)

Q.3) for proper synchronization of large syn. Machine to a bus ,frequency of incoming machine should be:a) b) c) d) Exactly the same as that of the bus. Slightly higher than that of the bus Slightly lower than that of the bus Of any value.

Q.4) an alternator is operating on infinite bus .it will develop maxm synchronizing power when it is operating at: a) b) c) d) No load Its steady state stability limit Full load Any load

Q.5) the power angle characteristics of machine infinite bus system is-infinite bus system is-pe=2sin Pu. It is operating at =30 .its synchronizing power co-efficient at operating point is: a) 1.0 b) 2.0 c) d)

Q.6: Which one of the following is the primary reason for placing field on rotor in an alternator? a) b) c) d) Smaller power in field current Insulation of high voltages is made easy on stator than rotor Large power in stator Large current in the stator

Q.7: In a salient pole syn. Machine air gap is: a) b) c) d) Uniform under the whole pole shoe Least under the middle of the pole shoe and increases outwards largest under the middle of the pole shoe and decreases outwards Largest at one end of the pole shoe and increases to the maximum value at other end.

Q.8: slip test of salient pole machine yields: (Id) max=10A (Id) min=6.5A (Vd) max=30V (Vd) min=25V

Then which of the following is correct? a) b) c) d) Xd=3, Xq =3.86 Xd=4.615, Xq=2.5 Xd =3,Xq=2.5 Xd =4.61,Xq=3.86

Q.9: The resultant flux density in the air gap of a syn. Generator is the lowest during a) b) c) d) Open circuit Solid short ckt Full load half load

Q.10: A field excitation of 20A in a certain alternator results in an armature current of 400 A in short circuit and a terminal voltage of 2000 V on an open circuit ,The magnitude of the internal voltage drop within the machine at a load current of 200 A isa) b) c) d) 1V 10V 100V 1000V

Q.11: The voltage across the open circuited field terminals of synchronous machine under slip test is: a) b) c) d) Dc Ac of slip freq. A modulated supply freq. ac voltage with slip freq envelope. None of these

Q.12: A synch generator connected to an infinite bus is supplying electrical power at unity p.f to the bus .if its field current is now increased: a) Both active and reactive power of the generator will remain unchanged. b) The active power supplied will remain constant but the machine will also supply lagging reactive power c) Active power supply will increase and the machine will draw leading reactive power. d) Active power will decrease and machine will supply leading reactive power. Q.13:a 3-ph alternator delivers power to a balanced 3-phase load of power factor 0.707 lagging .it is observed that the open circuit emf phasor leads the corresponding terminal voltage phasor by 15 .neglecting effects of harmonics the angle b/w the axis of the main field mmf and the axis of the armature mmf will bea) b) c) d) 30 60 90 150 electrical

Q.14: In an alternator ,freq per revolution is equal to: a) b) c) d) No. of poles Twice the no. of poles Speed in rpm No. of pole pairs

Q.15: If the E1, E3 and E5 are respectively the rms value of the fundamental, third and fifth harmonic voltage generated in each phase of a Y-connected alternator, then the line voltage isa) 3 b) c) d)