Location Owner Design Parameters Dimention of Column 1 Dimention of Column 2 Column 1 Live Load Column 1 Dead Load Column 2 Live Load Column 2 Dead Load Spacing Between Two Columns Depth fron NG to Base of Footing Soil Bearing Capacity Unit Weight of Soil Unit Weight of Concrete fc' fy Main Reinforcement Bar Solving for Size of Footing P1 x1 P2 x2 P xg qe Aftg L B Depth of Footing Pu1 Pu2 Pu qu d
= 0.3 mm x 0.3 mm = 0.3 mm x 0.3 mm = 320 KN = 500 KN = 350 KN = 500 KN = 4.2 meters = 2 meters = 200 KPa = 18 KN/m^3 = 24 KN/m^3 = 25 MPa = 300 MPa = 14 mm
= 0.00467 KN = 0.00015 meters = 0.00583 KN = 4.20015 meters = 1670 KN = 2.138 meters = 159.86 KPa = 10.45 m square = 4.28 meters = 2.4 meters
Check "d" for two-way or punching shear: For Column 1 bo = 1.2 meters Vu = 1199.44 KN Vc = 1200000 KN oVc = 1020 KN Insuficient effective depth
Check "d" for one-way or wide beam shear: Vu1 = -887.9 KN Vu2 = 891.6 KN Vu3 = 128.6 KN Max Vu Vc oVc Use d Total Depth Design of Main Bars Along Length w1 w2 wu v1 v2 v3 v4 M1 M2 M3 M4 pmax pmin Section Moment, Mu Ru p Use p As Number of bars, N Use N Location = 891.6 KN = 1200000 KN = 1020 KN OK = 600 mm = 690 mm
= 4146667 KN/m = 4316667 KN/m = 593.22 KN/m = 1243.822 KN = 0 KN = 1247.524 KN = -47.298 KN = -0.19 KN-m = -1304.33 KN-m = 7.25 KN-m = 1.88 KN-m = 0.0301 = 0.00467
Section Moment, Mu Ru p Use p As Number of bars, N Use N Location Development Length Ld Minimum Ld Furnished
Use 4.28 m x 2.4 m footing with an effective depth to top bars of 600 mm (total depth = 690 mm), with 99 pcs 14 mm bars for top location on long direction, 88 pcs - 14 mm bars for bottom location on long direction, 9 pcs - 14 mm bars for column 1 location on short direction and 9 pcs - 14 mm bars for column 2 location on short direction of the footing, and at least two column bars mm bars must be extended in the footing.
Print Result
Edit Design
New Design