BMC Software is releasing version 20.11.01 of the BMC Atrium Orchestrator content. This release includes changes to base and application adapters and run books only, and not the platform. BMC Atrium Orchestrator content version 20.11.01 is certified with BMC Atrium Orchestrator platform version 7.6.02.00 only. BMC Atrium Orchestrator content version 20.11.01 is not supported on platform versions earlier than 7.6.02.00. This document provides information about corrected problems and known issues in this release. These release notes supplement the information in the BMC Atrium Orchestrator product manuals.
NOTE
Before you install the product, check the Customer Support website at http://www.bmc.com/support for:
s s s
Updated documentation (for example, flashes and technical bulletins) Product downloads, patches, and fixes Product availability and compatibility (PAC) data
The following topics are discussed: Release versioning scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Change in location of compatibility and operating system support information . . . . Whats new . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BMC Atrium Orchestrator Application Adapter for Microsoft System Center Configuration Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BMC Atrium Orchestrator Run Book for Discovery Synchronization . . . . . . . . . . Whats changed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Attribute support in the form view for adapter configuration. . . . . . . . . . . . . . . . . Enhancements to the base adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HTTP adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IMAP and POP adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Telnet, SSH, and Command Line adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Form view for adapter configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BMC Atrium Orchestrator Application Adapter for VMware vCloud. . . . . . . . . . 3 3 3 3 4 4 4 5 5 5 6 6 7
*186216* *186216*
*186216*
New operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 New monitor adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Dynamic adapter configuration support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Compose vApp operation enhancements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 BMC Atrium Orchestrator Application Adapter for BMC BladeLogic Network Automation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 New configuration element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Application version support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Renamed element in Perform Custom Action operation . . . . . . . . . . . . . . . . . . 8 BMC Atrium Orchestrator Application Adapter for BMC Event Manager and BMC ProactiveNet Performance Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Integration of BMC EM with BMC ProactiveNet Performance Manager. . . . . 9 Change in the book title . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Application version support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 BMC Atrium Orchestrator Application Adapter for Amazon EC2 . . . . . . . . . . . . 10 Adapter configuration enhancement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Dynamic mode for signing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 BMC Atrium Orchestrator Application Adapter for BMC BladeLogic Server Automation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Support for BMC BladeLogic Web Services interface . . . . . . . . . . . . . . . . . . . . 10 Application version support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 BMC Atrium Orchestrator Application Adapter for VMware Infrastructure . . . 11 New operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Application version support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 BMC Atrium Orchestrator Application Adapter for BMC Remedy AR System . 12 Set and Update operations enhancement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Application version support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 New configuration element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 BMC Atrium Orchestrator Application Adapter for Cisco LAN Management Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Run book names updated in the content installation program. . . . . . . . . . . . . . . . 12 BMC Continuous Compliance for Servers Run Books . . . . . . . . . . . . . . . . . . . . . . . 13 Closed Loop Server Audit Run Book . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Server Incident Enrichment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Operations Actions Configuration Management Module . . . . . . . . . . . . . . . . . . . . 13 Adapters, modules, run books, and solutions included in the content installation program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 License entitlements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Corrected problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Issues resolved in the 7.6.05.01 content patch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Known issues. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Workarounds for INSTALL-1273 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Installing BMC Atrium Orchestrator content. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Downloading the licensed product from the EPD website . . . . . . . . . . . . . . . . . . . 31 Prerequisites for installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Silent installation names for adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Where to view the latest product information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Product documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Customer support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Support website . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Whats new
This release introduces the following new application adapter and new run book.
BMC Atrium Orchestrator Application Adapter for Microsoft System Center Configuration Manager
The BMC Atrium Orchestrator Application Adapter for Microsoft System Center Configuration Manager consists of an actor and a monitor adapter. The actor adapter executes operations on the Microsoft System Center Configuration Manager application by running VBScripts from the command line. The monitor adapter polls the Microsoft System Center Configuration Manager application for events after a preconfigured interval. Based on the search criteria defined in the monitor configuration, the monitor adapter generates events for the BMC Atrium Orchestrator adapter manager. The events are then used by workflows. The BMC Atrium Orchestrator Application Adapter for Microsoft System Center Configuration Manager supports the software deployment use case.
For more information about the Microsoft System Center Configuration Manager adapter, see the BMC Atrium Orchestrator Application Adapter for Microsoft System Center Configuration Manager User Guide.
Whats changed
This section describes enhancements and changes in base and application adapters, run books, and modules.
Base and application adapters now support the encryption-type attribute, which indicates whether the password or the pass phrase specified is encrypted and is an attribute of the <password> or the <passphrase> element. The following base adapters support attributes in the form view:
s s s s
s s s s
EMC CLARiiON Storage HP AssetCenter HP Operations Manager HP Service Center HP Service Desk HP Network Node Manager
s s s s s s
HP Service Manager IBM Tivoli Storage Manager Microsoft System Center Operations Manager NetApp Storage Service-now Solaris Zones
For more information about the attribute support enhancement, see the BMC Atrium Orchestrator Base Adapters User Guide or the corresponding BMC Atrium Orchestrator application adapter user guide.
HTTP adapter
The HTTP adapter now has a new configuration element, <proxy-ntlmauthentication> that specifies the type of authentication to support NTLMv2. The adapter now supports both NTLMv1 and NTLMv2 authentication for the proxy server and the target server.
The form view for the IMAP adapter configuration now contains the Ignore Peer Name In Attachment field that adds or removes the peer name from an email event XML. The IMAP and POP adapters now each have the following new configuration elements:
s
<expand-htmltext-attachment>: Specifies whether the HTML data content of a message that is sent as an attachment appears in the <bodypart> element in an adapter event. <expand-plaintext-attachment>: Specifies whether the plain text content of a message that is sent as an attachment appears in the <bodypart> element in an adapter event.
Also, these adapters support nested (forwarded) emails. The adapter event XML contains the following elements, which are added as child elements to one of the <bodypart> elements in the header:
s s s s s s
New operations
The BMC Atrium Orchestrator Application Adapter for VMware vCloud now supports the following operations:
s
Template Management operations Clone vApp Template Get vApp Template OVF Descriptor Import OVF as vApp Template Delete vApp Template Export vApp Template as OVF Network Management operations Create Organization Network Delete Organization Network Modify Organization Network Organization Management operations Create Organization Delete Organization Modify Organization
BMC Atrium Orchestrator Application Adapter for BMC BladeLogic Network Automation
BMC Atrium Orchestrator Application Adapter for BMC BladeLogic Network Automation
This section describes the enhancements for the BMC Atrium Orchestrator Application Adapter for BMC BladeLogic Network Automation. For more information about these enhancements, see the BMC Atrium Orchestrator Application Adapter for BMC BladeLogic Network Automation User Guide.
BMC Atrium Orchestrator Application Adapter for BMC Event Manager and BMC ProactiveNet Performance Manager
BMC Atrium Orchestrator Application Adapter for BMC Event Manager and BMC ProactiveNet Performance Manager
This section describes the enhancements for the BMC Atrium Orchestrator Application Adapter for BMC Event Manager and BMC ProactiveNet Performance Manager. For more information about these enhancements, see the BMC Atrium Orchestrator Application Adapter for BMC Event Manager and BMC ProactiveNet Performance Manager User Guide.
Compatible with BMC Compatible with BMC Event Manager 7.2.01? Event Manager 7.3? Yes No Yes Yes
BMC Atrium Orchestrator Application Adapter for BMC BladeLogic Server Automation
This section describes the enhancements for the BMC BladeLogic Server Automation adapter. For more information about these enhancements, see the BMC Atrium Orchestrator Application Adapter for BMC BladeLogic Server Automation User Guide.
10
NOTE
The BMC BladeLogic Web Services interface supports authentication based on Secure Remote Protocol (SRP) only and is available in BMC BladeLogic Server Automation version 8.1 only.
New operations
The VMware Infrastructure actor adapter now supports the following new operations:
s
vApp Configuration operations Import OVF Template As vApp Export vApp As OVF Template VM Configuration operations Create vApp Clone vApp Update vApp Configuration Import OVF Template As VM Export VM As OVF Template Basic vApp operations Power On vApp Power Off vApp Unregister vApp
11
BMC Atrium Orchestrator Application Adapter for Cisco LAN Management Solutions
The BMC Atrium Orchestrator Application Adapter for Cisco LAN Management Solutions will no longer be supported and support is withdrawn.
12
Table 3 lists the run books that have been deleted or renamed in the 20.11.01 content installation program. Table 3 Run books updated in the 20.11.01 content installation program
Run book name in 20.11.01 content installation program Removed (now available only in the BMC Cloud Lifecycle Management solution) Continuous Compliance for Network (renamed) Continuous Compliance for Server (renamed)
Run book name in the 7.6.05 content installation program Server Instance SA Placement Engine Closed Loop Change Management Continuous Compliance for BladeLogic
NOTE
If BMC BladeLogic Decision Support for Server Automation is installed with a non-default port number, update the Server Name item as ServerName:portNumber.
13
Adapters, modules, run books, and solutions included in the content installation program
Adapters, modules, run books, and solutions included in the content installation program
The following adapters are included in the BMC Atrium Orchestrator content installation program:
s
Base Adapters Amazon EC2 Atrium CMDB BMC BladeLogic Network Automation BMC BladeLogic Server Automation BMC Event Manager and ProactiveNet BMC Performance Manager Portal BMC Remedy Action Request (AR) System EMC CLARiiON Storage HP Asset Center HP Network Node Manager
HP Operations Manager (for Windows and UNIX) HP Service Center HP Service Desk HP Service Manager HP Storage Essentials IBM Tivoli Netcool OMNIbus IBM Tivoli Storage Manager Service-now Solaris Zones Microsoft Active Directory Microsoft Exchange 2003
Microsoft Exchange 2007 Microsoft Operations Manager 2005 Microsoft System Center Configuration Manager Microsoft System Center Operations Manager NetApp Rapid Cloning Utility NetApp Storage VMware Infrastructure VMware Lifecycle Manager VMware vCloud
s s
s s
The following run books are included in the BMC Atrium Orchestrator content installation program:
s s
Continuous compliance for Network Continuous compliance for Server BladeLogic ITSM Integration Closed Loop Server Audit Closed Loop Server Compliance Server Incident Enrichment
s s s
14
License entitlements
The following Operations Actions (OA) management modules are included in the BMC Atrium Orchestrator content installation program:
s s
AutoPilot OA Change Management AutoPilot OA Configuration Management AutoPilot OA Configuration Utilities AutoPilot OA Credentials Store AutoPilot OA Event Management
s s
AutoPilot OA Incident Management AutoPilot OA Problem Management AutoPilot OA Task Management AutoPilot OA Storage Management AutoPilot OA Virtual Server Management
s s s
s s s
The following core modules are included in the BMC Atrium Orchestrator content installation program:
s s s s
AutoPilot AD Utilities AutoPilot OA Applications Utilities AutoPilot OA Common Utilities AutoPilot OA Directory Services Utilities
s s s s
AutoPilot OA File Utilities AutoPilot OA Network Utilities AutoPilot OA Operating System Utilities AutoPilot OA Physical Device Utilities
The following solutions are included in the BMC Atrium Orchestrator content installation program:
s
BMC Continuous Compliance for Networks BMC Continuous Compliance for Servers BMC NetApp Solutions
s s
License entitlements
Table 4 lists the license entitlements for the BMC Atrium Orchestrator version 20.11.01 product content. Table 4 License entitlements for the BMC Atrium Orchestrator version 20.11.01 product content (part 1 of 2)
BMC product descriptions and license rights Base adapters are system interfaces, gateways, or connectors used to talk to thirdparty systems by using a standard protocol (SNMP, command line, SSH, Telnet, JMS, SOAP, and so forth.). This component is licensed per adapter, with each unique adapter requiring a separate license.
15
Corrected problems
Table 4
License entitlements for the BMC Atrium Orchestrator version 20.11.01 product content (part 2 of 2)
BMC product descriptions and license rights Application adapters are predeveloped, out-of-the-box system interfaces, gateways, or connectors used to talk to vendor-specific (but not BMC) applications (HP Storage Essentials, Microsoft Active Directory, VMware Virtual Infrastructure, and so forth). This component is licensed per adapter, with each unique adapter requiring a separate license. Run books are collections of prebuilt workflows that automate end-to-end processes in a particular domain. Each run book is licensed per instance, with each unique run book requiring a separate license.
Corrected problems
The following problems were reported earlier and were corrected in this version. Table 5
Support ID None None
ISS03681327 ISS03702185
The IMAP monitor adapter event did not include the MIME type (HTML or plain text) of an attachment. In the BMC Atrium Orchestrator Application Adapter for BMC BladeLogic Server Automation, when you executed an NSH script from the default directory, the script failed. The POP adapter did not process the queue of emails when it resumed from a fault state or when it was restarted. The Update Incidents workflow in the OA-Incident Management module reorganized the description fields.
None
ADAPTER-4502
ISS03711077 ISS03718548
ADAPTER-4511 MODULE-2743
16
None
ADAPTER-4571
The BMC Atrium Orchestrator Application Adapter for BMC BladeLogic Network Automation did not support the <allowunsigned-certificate> element that was required for certificate installation. The <vcenter-server-version> element in the BMC Atrium Orchestrator Application Adapter for VMware Infrastructure that specified the target vCenter server version was not supported at the adapter request level. This caused dynamic target functionality to fail if the target environment contained vCenter servers with different versions.
None
ADAPTER-4490
17
Known issues
Known issues
The following issues remain open in this release. Table 7
Support ID Installation issues None INSTALL-1235 The BMC Atrium Orchestrator content installer fails to install the Continuous Compliance for Networks solution, displaying Failed to install ITSM extensions. Workaround: 1. Using an account with administrative privileges, log on to BMC Remedy AR System. 2. In the Quick Links section, click AR System Administration Console. 3. Select the System > General > Server Information > Configuration tab. 4. Select the Development Cache Mode and Enable Multiple Assign Groups check boxes. 5. Click Apply. 6. Install the Continuous Compliance for Networks solution. None INSTALL-1273 When you create a change request (CR) with invalid assignment details in the task template, the following message is displayed: The Assignment Information is not valid. Use the menus provided on the 'Assignee Company', 'Assignee Organization' and 'Assignee Group' or the type ahead return function on the 'Assignee Group' or 'Assignee fields' fields to select this information. Also, assignment issues occur for the following solutions:
s s s
Workaround: For detailed instructions, see Workarounds for INSTALL-1273 on page 29.
18
Known issues
Table 7
Support ID None
Upgrade issues None AMP-17536 The BMC Atrium Orchestrator Application Adapter for VMware Infrastructure, which requires a certificate does not work when you upgrade from platform version 7.6.01.04 to 7.6.02. The Windows Command adapter response displays The handle is invalid. <command>commandName</command> intermittently when you specify a request with multiple targets. For base adapters in a Linux environment, if an error occurs in the OS close() operation, subsequent calls re-attempt the close() operation. The SQL monitor adapter cannot invoke a stored procedure containing an OUT parameter in MY SQL. When you use the form view to configure the base and application adapters, the description is not consistent and contains punctuation errors. The Web Services adapter displays two lines of unnecessary warning messages, which correspond to each outbound web service message. If you specify invalid values in the form view when configuring an adapter, switching to the XML view does not populate these incorrect values within the respective elements.
None
ADAPTER-293
None None
ISS03617538 None
19
Known issues
Table 7
Support ID None
None
ADAPTER-4418
When you specify the soap URL without specifying the port number using the Web Services adapter, the CertificateManagement instance is not created. A NullPointerException is displayed and the certificate is not installed in the cacerts file. Workaround: Specify the soap URL with the port number even if you use the default port. For example, specify: https://hostName:portNumber (for any other port other than default) https://hostName:443 (for default port)
None
ADAPTER-4455
For the Poll Asynchronous method in the JAX-WS approach, concurrent Web Services adapter requests do not work using different user credentials. The <verify-os> element does not work as expected for SCP, FTP, and SFTP adapters. When you execute the get-dir command using the SFTP adapter, the adapter response displays an error and the operation is unsuccessful. When you execute the put-dir command specifying an incorrect path for a local folder or both, local and remote folders, using the SFTP adapter, the adapter response displays success without an error message. The <ktgt-cache-file-name> element is incorrectly accepted as <ktgt-cache-filename> when you configure the KSSH adapter using the form view. Workaround: Switch to the XML view and modify the <ktgt-cachefilename> element.
None
ADAPTER-4733
None
ADAPTER-4744
For the Telnet adapter, the form view displays the default value of Login Prompt as "login" instead of "login:" and the default value of Password Prompt as "Password" instead of "Password:."
20
Known issues
Table 7
Support ID None
None
ADAPTER-4642
The Create_VApp operation does not create a vApp under a resource pool where the resource pool exists under a vApp. The valid values in the description for the Preferred PK Algorithm field should be ssh-dss and ssh-rsa instead of ssh Dss and ssh Rsa. With version 8.0 (SP4) and later releases of the BMC BladeLogic Server Automation application, the adapter does not select the correct executable with the desired extension and displays the Could not find jvm_path message. Workaround: 1. Create a system variable named NSHDIR and set its value to C:\Program Files\BMC Software\BladeLogic\8.0\NSH. 2. Add %NSHDIR%\bin to the systems path variable (if it does not already exist). 3. Restart the CDP server.
21
Known issues
Table 7
Support ID None
None
ADAPTER-4322
The nexec command does not correctly handle NSH scripts with arguments that have empty values when executed on a remote computer. Workaround: When executing NSH scripts on a remote computer, specify arguments that have empty values as single quotes within double quotes ("''").
A single NSH script or command executed on a 64-bit computer opens multiple sessions. The <exit-code> and <status> elements are incorrectly set for Jython scripts in the adapter response. NSH commands do not execute correctly when the <timeout-secs> element specified in the configuration or request is equal to the command execution time. If the arguments for a script have leading or trailing spaces for multiple arguments, the spaces are not retained in the response for all the arguments. However, for a single argument, spaces are retained. The Get Message operation does not support the <recipientsinfo> element because the value of this element is first stored in a variable and then extracted to display information about recipients. You must specify the <name> element within the <parameter> element to execute adapter requests. If you specify only the <value> element without the <parameter> element, the adapter does not use the <value> element because it does not support positional parameters. The Get Distribution Group Member operation does not support the <credential> element. The <server> element is required for the New Receive Connector operation when the Microsoft Exchange server is installed on a 32-bit computer. If you specify the distinguished name within single quotes in adapter requests, an error message is displayed. The <RecipientFilter> element in the Set Dynamic Distribution Group operation does not work. The <SourceTransportServers> element is required in the New Send Connector operation to define a send connector.
None
ADAPTER-4704
None
ADAPTER-3380
None None
ADAPTER-3381 ADAPTER-3382
22
Known issues
Table 7
Support ID None
None
ADAPTER-3403
None None
ADAPTER-3405 ADAPTER-3408
None
ADAPTER-3409
None
ADAPTER-1370
None None
ADAPTER-1371 ADAPTER-1374
The register-image operation does not add root device and block device mapping information to the Amazon Machine Image (AMI). The describe-image-attribute operation response does not retrieve kernel, ramdisk, and block-device-mapping information of the created image. The <groups> element in the authorize-security-groupingress operation request does not work. The delete-key-pair operation response displays success when you specify a nonexistent key pair in the request. The describe-image-attribute operation displays success when you specify more than one conditional parameter.
23
Known issues
Table 7
Support ID None
None
ADAPTER-1383
BMC Event Manager and BMC ProactiveNet Performance Manager adapter issues None None ADAPTER-1679 ADAPTER-1733
None
ADAPTER-1756
VMware vCloud adapter issues None None None None ADAPTER-4351 ADAPTER-4436 ADAPTER-4441 ADAPTER-4463
24
Known issues
Table 7
Support ID None
None
ADAPTER-4612
The Add Organization Network operation does not create a NATrouted network. However, the adapter response shows successful execution. The Add Organization Network operation does not add multiple IP ranges when creating a new network. The Modify Organization Network operation displays Cannot update-undeploy the network first when you update the network's fence mode. The Modify Organization Network operation does not update the modified network with the value specified in the <network-poolid> element. A similar issue occurs with the <parent-network-id> element for a bridged network.
None None
ADAPTER-4621 ADAPTER-4623
None
ADAPTER-4624
None None
ADAPTER-4662 ADAPTER-4663
The Create Organization operation does not support MD5DIGEST and NTLM values for the <authentication-mechanism> element. The Create Organization operation does not add the following elements specified in the adapter request to the newly created organization:
s s s
None None
ADAPTER-4673 ADAPTER-4717
The Create Organization operation does not allow you to specify the SMTP server port. The <vm-startup-details> element does not work when the vApp template is specified in the Compose_vApp operation. In the BMC Atrium Orchestrator Application Adapter for VMware Lifecycle Manager User Guide information for the Apply Placement operation, the <comment> element is incorrectly marked as required. This element is optional. In the BMC Atrium Orchestrator Application Adapter for VMware Lifecycle Manager User Guide information for the Apply Placement operation, the <shapingTemplate> element is incorrectly marked as required. This element is optional.
None
ADAPTER-2564
25
Known issues
Table 7
Support ID None
Microsoft System Center Configuration Manager adapter issues None BMCCAT-2684 The actor and monitor adapters cannot be enabled on a peer installed on the same computer as the Microsoft System Center Configuration Manager application. The Windows 2008 server systeminfo command does not return the System Up Time parameter value in its output. Without the System Up Time value, the validation phase of the Server Restart and Server Start workflows fails. Workaround: 1. Download the uptime.exe utility from the Microsoft Support website at http://support.microsoft.com/kb/232243. 2. Install the uptime.exe utility in the Windows\System32 directory or in the directory of your choice. Make sure that the Windows\System32 directory, or whatever directory you save the utility to, is defined in the system path variable of the Windows 2008 server host computer. The Server Restart and Server Start workflows automatically invoke the uptime.exe utility and parse its output to extract the system uptime value. None MODULE-2704 The AutoPilot-OA-Operating_System_Utilities:Service_Controller :Create SC workflow fails if the binary path contains a space. For example, the command, C:\Users\Administrator>sc \\10.20.88.45 create TestService binpath= C:\Program Files\BMC BladeLogic\NSH\bin\awk.exe displayname= myService fails because there is a space between the words Program and Files.
26
Known issues
Table 7
Support ID None
None
MODULE-2720
Get Interface Duplex Get Interface Queue Drops Get Interface Speed Get Interface Status
MODULE-2758 MODULE-2744
The Problem Management module cannot create a new known issue. Using the Operator Initiated Change in the BMC Continuous Compliance for Servers Run Book after BMC BladeLogic starts to run the requested job, the IT Service Management (ITSM) Task status does not change from Assigned to Work In Progress. The task remains in the Assigned status.
27
Known issues
Table 7
Support ID
ISS03728336
None
MODULE-2770
In the Triage and Remediation run books, an incident is not closed after a change request is completed in ITSM 7.6.04. Use the following BMC Remedy AR System configuration steps as a workaround to resolve the issue. Workaround using BMC Remedy AR System Developer Studio: 1. Launch BMC Remedy AR System Developer Studio. 2. Log in as an administrator. 3. Navigate to All Objects > Filters and then double-click Filters. 4. In the window listing all the filters, search for AO:TR:Common:Change filter. 5. Open the filter and in Execution Options, change the execution order from 500 to 912. 6. Click Save. Workaround using BMC Remedy AR System User Tool: 1. Launch BMC Remedy AR System User Tool. 2. Log in as an administrator. 3. In the Quick Links panel, click Application Administration Console. 4. In Application Administration Console, click the Custom Configuration tab. 5. Expand Incident Management > Advanced Options and then double-click Rules. 6. In the Incident Rules windows, for Assignment Engine Integration, select Yes. 7. Click Save.
28
To create a change request with valid assignment details in the task template for the Continuous Compliance for Servers solution 1 Navigate to the BMC Remedy AR System home page. 2 In the Quick Links section, click Application Administration Console. 3 Click the Custom Configuration tab and then select Task Management System >
Template.
4 Open the BladeLogic Audit Task Template task template. 5 Click the Assignment tab. 6 Select the same values from the list that you specified at installation for the
following fields, and then click Save:
s s s s s
BladeLogic Compliance Task Template Operator Initiated Change Task Template BladeLogic Audit Task Template
To create a change request (CR) with valid assignment details in the task template for the Triage and Remediation solution 1 Navigate to the BMC Remedy AR System home page. 2 In the Quick Links section, click Application Administration Console. 3 Click the Custom Configuration tab and then select Task Management System >
Template.
29
4 Open the Triage Remediation DB Tablespace Full task template. 5 Click the Assignment tab. 6 Select the same values from the list that you specified at installation for the
following fields, and then click Save:
s s s s s
Triage Remediation ESX Host Not Responding Triage Remediation Failed Backup Recovery Triage Remediation OS Disk Space Full Clean Temp Triage Remediation OS Disk Space Full Compress Logs Triage Remediation OS Disk Space Full Delete Cache Triage Remediation Server Actions Triage Remediation Service Actions Triage Remediation DB Tablespace Full
To create a change request (CR) with valid Assignment Details in the task template for the NetApp solution 1 Navigate to the BMC Remedy AR System home page. 2 In the Quick Links section, click Application Administration Console. 3 Click the Custom Configuration tab and then select Task Management System >
Template.
4 Open the Storage Provisioning Provision Storage Task task template. 5 Click the Assignment tab. 6 Select the same values from the list that you specified at installation for the
following fields, and then click Save:
30
s s s s s
Storage Provisioning Provision Virtual Server Task Storage Provisioning Provision Storage Task
To download the licensed product from the EPD website 1 Create a directory in which to place the downloaded files. NOTE
On Windows computers, ensure that the directory is only one level into the directory structure. The EPD package creates a directory in the temporary directory when you extract the files, and the directory that contains the installation image should not be in a directory deeper than two levels into the directory structure.
31
2 Go to https://webapps.bmc.com/signon/content/logon.jsp. 3 Enter your user ID and password, and click Submit. 4 Click Download Product. 5 On the Export Compliance and Access Terms page, provide the required
information, agree to the terms of the agreements, and click Continue.
6 If you are accessing this site for the first time, create an EPD profile; otherwise, skip
to step 7 on page 32:
A Under Localized Languages, select the language for the licensed product release. B Under Install Platforms, select the platforms to download for the licensed
product.
C Click Save Profile. 7 Verify that the correct profile is displayed for your download purpose, and select
the Licensed Product tab.
8 Locate the licensed product: A Locate the product name and expand its entries to show the available version
numbers.
B Select the check box next to the licensed product and documents to download. 9 To download the selected items, click Download (FTP) or Download Manager:
s
Download (FTP) places the selected items in an FTP directory, and the
resume an interrupted download if the connection is lost. This method requires a one-time installation of the AkamiNetSession Client program on the target computer and is usually the faster and more reliable way to transfer files. A checksum is used to verify file integrity automatically.
You must have the Access Manager and repository platform components installed and running.
32
You can find the complete instructions for installing and configuring the BMC Atrium Orchestrator platform components in the BMC Atrium Orchestrator Installation Guide. This guide is located on the BMC Customer Support website at http://webapps.bmc.com/support/faces/az/prodversion.jsp?prodverseqid=190 115.
s
The computer from which you run the installation program must have network access to the repository.
To install BMC Atrium Orchestrator content with the GUI installation program 1 Navigate to and start the installation program.
s s
2 On the Welcome panel, click Next. 3 On the license agreement panel, select I agree to the terms of the license agreement
then click Next.
4 On the Directory Selection panel, accept the default location, or click Browse to
select a different location and click Next.
5 On the Installation Type panel, select Custom feature set, and click Next.
Do not select BSM Solutions unless you have purchased a BMC solution and have reviewed the applicable documentation for that solution.
NOTE
If you select existing application adapters or base adapters, they will be updated to the current version when you click Install.
33
7 On the Adapter feature selection panel, select the adapters to install, and click Next:
s s
To select all adapters, select Adapters. To select all the adapters in a group, select Base adapters, BMC application adapters, or Third party adapters.
8 On the Module feature selection panel, select the run books, management
modules, and core modules to install, and click Next:
s s
To you select all modules, select Modules. To select all the modules in a group, select Run books, Management modules, or Core modules.
NOTE
You can find additional logging for BMC Remedy ITSM artifacts in the installationHome/import-logs folder only when you install a solution.
9 On the Installation Preview panel, review the features. When you have finished
reviewing the summary, click Install.
For a complete list of silent installation names for adapters, see the BMC Atrium Orchestrator Installation Guide.
34
Product documents
The following documents support the product and are introduced in this release:
s
BMC Atrium Orchestrator Application Adapter for Microsoft System Center Configuration Manager User Guide BMC Atrium Orchestrator Run Book for BMC Discovery Synchronization Getting Started Guide
s s s s s
s s
BMC Atrium Orchestrator Application Adapter for HP Network Node Manager User Guide BMC Atrium Orchestrator Application Adapter for HP Service Desk User Guide BMC Atrium Orchestrator Application Adapter for HP ServiceCenter User Guide BMC Atrium Orchestrator Application Adapter for Microsoft Exchange 2003 User Guide BMC Atrium Orchestrator Application Adapter for Microsoft Exchange 2007 User Guide BMC Atrium Orchestrator Application Adapter for Microsoft Active Directory User Guide BMC Atrium Orchestrator Application Adapter for Microsoft Operations Manager 2005 User Guide BMC Atrium Orchestrator Application Adapter for VMware Lifecycle Manager User Guide BMC Atrium Orchestrator Application Adapter for VMware Infrastructure User Guide BMC Atrium Orchestrator Application Adapter for Microsoft System Center Operations Manager 2007 User Guide BMC Atrium Orchestrator Application Adapter for BMC Event Manager and BMC ProactiveNet Performance Manager User Guide BMC Atrium Orchestrator Application Adapter for BMC BladeLogic Server Automation User Guide
35
Customer support
s s s s s
s s s s s
s s s s s s
BMC Atrium Orchestrator Application Adapter for BMC Performance Manager Portal User Guide BMC Atrium Orchestrator Application Adapter for BMC BladeLogic Network Automation User Guide BMC Atrium Orchestrator Application Adapter for BMC Remedy AR System User Guide BMC Atrium Orchestrator Application Adapter for BMC Atrium CMDB User Guide BMC Atrium Orchestrator Application Adapter for HP Asset Center User Guide BMC Atrium Orchestrator Application Adapter for HP Operations Manager User Guide BMC Atrium Orchestrator Application Adapter for IBM Tivoli Storage Manager User Guide BMC Atrium Orchestrator Application Adapter for IBM Tivoli Netcool OMNIbus User Guide BMC Atrium Orchestrator Application Adapter for HP Storage Essentials User Guide BMC Atrium Orchestrator Application Adapter for HP Service Manager User Guide BMC Atrium Orchestrator Application Adapter for NetApp Storage User Guide BMC Atrium Orchestrator Application Adapter for Amazon EC2 User Guide BMC Atrium Orchestrator Application Adapter for EMC CLARiiON Storage Adapter User Guide BMC Atrium Orchestrator Application Adapter for NetApp Rapid Cloning Utility User Guide BMC Atrium Orchestrator Application Adapter for VMware vCloud User Guide BMC Atrium Orchestrator Application Adapter for Solaris Zones User Guide BMC Atrium Orchestrator Application Adapter for Service-Now USer Guide BMC Atrium Orchestrator Base Adapters User Guide BMC Atrium Orchestrator Operations Actions Management Modules User Guide BMC Atrium Orchestrator Run Book for NetApp Solutions Getting Started Guide
To view the latest BMC documents, see the Customer Support website at http://www.bmc.com/support. Notices, such as flashes, technical bulletins, and release notes, are available on the website. You can subscribe to proactive alerts to receive e-mail messages when notices are issued or updated. For more information about proactive alerts, see the Customer Support website.
Customer support
You can obtain technical support by using the BMC Software Customer Support website or by contacting Customer Support by telephone or e-mail.
36
Support website
Support website
You can obtain technical support from BMC at http://www.bmc.com/support. From this website, you can:
s
Read overviews about the different levels of support services and other programs that BMC offers Find current information about BMC products Search the knowledge base for issues similar to yours and possible solutions, or for articles about the product Order or download product documentation Download products and maintenance Report an issue or ask a question Subscribe to receive proactive e-mail alerts when new product notices are released Find worldwide BMC support center locations and contact information, including e-mail addresses, fax numbers, and telephone numbers
s s
s s s s s
37
Copyright 2011 BladeLogic, Inc. BMC, BMC Software, and the BMC Software logo are the exclusive properties of BMC Software, Inc., are registered with the U.S. Patent and Trademark Office, and may be registered or pending registration in other countries. All other BMC trademarks, service marks, and logos may be registered or pending registration in the U.S. or in other countries. All other trademarks or registered trademarks are the property of their respective owners. BladeLogic and the BladeLogic logo are the exclusive properties of BladeLogic, Inc. The BladeLogic trademark is registered with the U.S. Patent and Trademark Office, and may be registered or pending registration in other countries. All other BladeLogic trademarks, servicemarks, and logos may be registered or pending registration in the U.S. or in other countries. All other trademarks or registered trademarks are the property of their respective owners. IBM, Netcool, and Tivoli are registered trademarks of International Business Machines Corporation in the United States, other countries, or both. Linux is the registered trademark of Linus Torvalds. Oracle and Java are registered trademarks of Oracle and/or its affiliates. Other names may be trademarks of their respective owners UNIX is the registered trademark of The Open Group in the US and other countries. The information included in this documentation is the proprietary and confidential information of BMC Software, Inc., its affiliates, or licensors. Your use of this information is subject to the terms and conditions of the applicable End User License agreement for the product and to the proprietary and restricted rights notices included in the product documentation. BMC SOFTWARE INC 2101 CITYWEST BLVD, HOUSTON TX 77042-2827, USA 713 918 8800 Customer Support: 800 537 1813 (United States and Canada) or contact your local support center
38