Anda di halaman 1dari 2

SUBMITTAL DATA SHEET

R-410A SPLIT SYSTEM CONDENSING UNITS MODELS: 13 SEER18K TO 60K


JOB NAME: PURCHASER: ENGINEER: SUBMITTED TO: SUBMITTED BY: UNIT DESIGNATION: FOR: REF: APPROVAL: DATE: SCHEDULE NO. MODEL NO. CONSTRUCTION: LOCATION: ORDER NO:

Heating & Air Conditioning

PRODUCT DATA Cooling Performance


W AIR DISCHARGE: ALLOW 60 MINIMUM CLEARANCE.

Total Capacity ________ MBH Outdoor Design Temp_________ F

Electrical Data
Power Supply____/___/_____ Compressor Ampacity _______AMPs Total Unit Ampacity ________AMPs Power Input Req__________KW Minimum Wire Size_________AWG Overcurrent Device Fuses Circuit Breaker
DETAIL A POWER WIRING SEE DETAIL A KNOCKOUT 1-11/32 (34.5mm) SERVICE ACCESS ALLOW 24 CLEARANCE AIR INLETS LOUVERED PANELS ALLOW 18 MINIMUM CLEARANCE

NOTE: GRILL APPEARANCE MAY VARY. CONTROL WIRING 7/8 (22.2mm)

Unit Weight
Unit Weight ________LBS

HOLE 1-3/32 (27.8mm) SERVICE FITTING LIQUID LINE CONNECTION DIMENSIONS VAPOR LINE CONNECTION

SERVICE FITTING

DIMENSIONAL DATA

MODEL SIZE 18(cooling unit) 18(heat pump unit) 24 30 36 42 48 60

Dimensions (Inches) "H" in. 24-15/16 24-15/16 24-15/16 24-15/16 24-15/16 29-7/8 33-3/16 33-3/16 "W" in. 21-7/8 23-5/8 23-5/8 28 29-1/8 28 28 29-1/8 "L" in. 21-7/8 23-5/8 23-5/8 28 29-1/8 28 28 29-1/8

Refrigerant Connection Service Valve Size Vapor in. Liquid in. 3/8 3/4 3/8 3/4 3/8 3/4 3/8 3/4 3/8 3/4 3/8 3/4 3/8 7/8 3/8 7/8
5

FEATURES
The compressor is protected against high/low pressure, tempera -ture by a factory installed high/low pressure switch and a tempe -rature sensor which protects the compressor if undesirable oper -ating conditions occur.

MATCHING AIR SIDE EQUIPMENT


Model No. Submittal Form No. ________________ ________________

FIELD INSTALLED ACCESSORIES


Off Cycle Timer () Thermostats Blower Off Delay () Hard Start Kit Low Ambient Pressure Switch ________________ ________________ ________________ ________________ ________________

A liquid line filterdrier is a optional part. We can also ship the unit with the filterdrier per install.

The muffler can make the unit operation more quiet and stable

The low pressure inspect valve can make the installation easy

Accumulator can make the compressor free of liquid-slugged

CLEARANCES
Service Access 18 Inches 6 Inches 60 Inches 0 Inches All Other Sides Above Unit Below Unit

Crankcase heater can protect the compressor when it stand by Low ambient temperature protection (5) High condenser coil temperature protection (127)

High quality heat-exchanger with inner-groove copper pipe and aluminum fin

Anti-rust: painted galvanized steel cabinet, 500 hours salt spray test

The operation ambient temperature rang is : AC 64-109 ; HP 14-109 ;

NOTES: ____________________________________________________________________________________________________ ____________________________________________________________________________________________________ ____________________________________________________________________________________________________ ____________________________________________________________________________________________________


Subject to change without notice. Copyright 2011 by Midea, Inc. All rights reserved.

Midea America Corp. 4 Campus Drive Parsippany,NJ 07054

Anda mungkin juga menyukai