This document provides information on cable termination and accessory products from Raychem, including:
- Heat shrinkable cable terminations for voltages up to 72kV and cable sizes from 4-16 mm2 to 500 mm2.
- Insulating boots, support insulators, and cable box glands for terminations.
- Earthing kits for bonding cable screens to ground for plastic cables with sizes from 16-1000 mm2.
- Heat shrinkable cable joints for voltages up to 72kV, cable sizes from 1.5-1000 mm2, and cable types including single-core, multi-core, armored and unarmored cables.
- Control cable joints for plastic
This document provides information on cable termination and accessory products from Raychem, including:
- Heat shrinkable cable terminations for voltages up to 72kV and cable sizes from 4-16 mm2 to 500 mm2.
- Insulating boots, support insulators, and cable box glands for terminations.
- Earthing kits for bonding cable screens to ground for plastic cables with sizes from 16-1000 mm2.
- Heat shrinkable cable joints for voltages up to 72kV, cable sizes from 1.5-1000 mm2, and cable types including single-core, multi-core, armored and unarmored cables.
- Control cable joints for plastic
Hak Cipta:
Attribution Non-Commercial (BY-NC)
Format Tersedia
Unduh sebagai PDF, TXT atau baca online dari Scribd
This document provides information on cable termination and accessory products from Raychem, including:
- Heat shrinkable cable terminations for voltages up to 72kV and cable sizes from 4-16 mm2 to 500 mm2.
- Insulating boots, support insulators, and cable box glands for terminations.
- Earthing kits for bonding cable screens to ground for plastic cables with sizes from 16-1000 mm2.
- Heat shrinkable cable joints for voltages up to 72kV, cable sizes from 1.5-1000 mm2, and cable types including single-core, multi-core, armored and unarmored cables.
- Control cable joints for plastic
Hak Cipta:
Attribution Non-Commercial (BY-NC)
Format Tersedia
Unduh sebagai PDF, TXT atau baca online dari Scribd
LL2I L5,LeI LLL. 4-26 CableTerminations Heat Shrinkable Type TERMINATION Raychem low voltage heat shrinkable terminations are available for the full range of cable types and sizes. They are acknowleged to be simpler, more reliable, and muchcheaper to intall than traditional systems. Catalog Number
Conductor Size Up to 1kV / Plastic Indoor / Outdoor Four Conductors
mm Not Armoured Wire Armoured
ESTU-OX/4C 4-16 ESTU-OX/4C 25-50 ESTU-OX/4C 70-150 ESTU-OX/4C 185-300 ESTU-OX/4C 500 ESTU-OX/4C 4-16 /WA ESTU-OX/4C 25-50 /WA ESTU-OX/4C 70-150 /WA ESTU-OX/4C 185-300 /WA ESTU-OX/4C 500 /WA 4-16 25-50 70-150 185-300 500 Raychem medium voltage heat shrinkable terminations offer outstanding long term reliability with over 20 years of proven performance in polluted environments. The installation accomodates simplified cable preparation techniques. The factory engineered kit along with clear instruction sheet permits rapid on-site installation. Termination Selector
Choosing one figure from the left-hand column of each table. Voltage (Vmax) Cable size Number of cores Dielectric Location Length (3 c o r e Typical part number: EPKT - 17 D 3 M I H2 Voltage in KV
7 17 24 36 for 7.2 KV for 12 KV and 17.5 KV Size in mm 7.2 KV 12 KV & 17.5 KV 24 KV 36 KV A B C D E F 16-50 70-120 150-240 300-500 630-1000
16-25 35-70 95-240 300-400 500-800 1000
25-50 70-185 240-300 400-630 800-1000
50-95 120-500 240-500 630-1000 Number of Cores
1 3 For Single (1) core For Three (3) core Dielectric or insulation type X M For PLASTIC eg. XLPE, EPDM, EPR, etc. For MIND non-draining paper (not applicable for draining paper cables) Location of Termination I O For INDOOR For OUTDOOR Length ( only three core) of the terminated portion (tail) H1 H2 H3 H4 for 450 mm long for 650 mm long (min for 17.5 KV outdoor and 36 KV indoor) for 800 mm long (min for 24 KV outdoor and 36 KV outdoor) for 1200 mm long A range of accessories for the above terminations are available. Single core kits contain components for 3 single core terminations. Lugs are not included in the kits and should be procured separately.
Raychem terminations are also available for 72KV voltage class. Please contact ADWAN for details. INSULATING BOOTS Raychem heat shrinkable insulating boots allow Raychem terminations to be used in conventional compound and oil filled boxes with air clearances. The design insures good insulation and impulse performance inspite of reduced clearances. The boots can be used with both paper and plastic cables upto 36KV. Catalog Number Conductor Size Straight Boots mm ESIB-4ST/10-35 ESIB-4ST/50-95 ESIB-4ST/120-300 ESIB-4ST/400-630 10-35 50-95 120-300 400-630 Catalog Number Catalog Number Conductor Size Right Angle Boots (Long)
(Short)
mm ESIB-4RL/10-35 ESIB-4RL/50-95 ESIB-4RL/120-300 ESIB-4RL/400-360 ESIB-4RL/70-500 ESIB-4RS/10-35 ESIB-4RS/50-95 ESIB-4RS/120-300 ESIB-4RS/50-95 10-35 50-95 120-300 400-630 70-500 SUPPORT INSULATORS Raychem light weight insulators comprise of a high strength flexible polymeric core housed in a Raychem proven high voltage material. The insulators are supplied with a galvanised iron mounting bracket and is used to support Raychem termination upto 36KV for outdoor use. All kits are supplied as a set of 3. Catalog Number Conductor Size ESIN-4 ESIN-6 up to 17.5 KV up to 36 KV CABLE BOX GLANDS Raychem cable box glands come complete with all the essential hardware for mounting the Raychem terminations. Typically used on cable boxes designed for compound filling where the distance from bushing to base plate is a limiting factor. Catalog Number Conductor Size mm ESGL-4S/3C 25-95 ESGL-4S/3C 120-300 25-95 120-300 Cable glands are available in aluminum for single core cable applications. Please contact ADWAN for details. EARTHING KITS Raychem earthing kits are available for solderless earthing of metal tape shield for plastic cables. Earthing kits are also available for steel wire, steel tape, aluminum wire, and corrugated aluminum armour. Catalog Number Core Dia.
50-150 JOINTS For jointing cables upto 36KV Raychem offers a system based on heat shrinkable materials which is; fast and simple to install, eliminates shelf life limitations, and offers high impact resistance and high earth fault current capacity. Millions of cable joints upto 36KV installed in some of the most severe service condition have confirmed the reliability of Raychem design under high electrical, thermal, and environmental stress. Catalog Number
Conductor Size Upto 1KV/Plastic Four Conductors (Not Armoured)
(Wire Armoured)
mm ESIJ-OX/4C 1.5-6 / NA ESIJ-OX/4C 6-16 / NA ESIJ-OX/4C 16-35/ NA ESIJ-OX/4C 35-70 / NA ESIJ-OX/4C 70-150 / NA ESIJ-OX/4C 150-300 / NA ESIJ-OX/4C 1.5-6 / SA ESIJ-OX/4C 6-16 / SA 1.5-6 6-16 25-50 70-150 185-300 Catalog Number Conductor Size Upto 7.2 ,KV/Plastic One Conductor (Without Armour)
mm ESIJ-2X/1C 25-50 / NA ESIJ-2X/1C 70-120 / NA ESIJ-2X/1C 150-185 / NA ESIJ-2X/1C 240-300 / NA 25-50 70-120 150-185 240-300 Catalog Number
Conductor Size Upto 7.2KV/Plastic Three Conductors (Without Armour)
(With Armour)
mm ESIJ-2X/3C 25-50 / NA ESIJ-2X/3C 70-120 / NA ESIJ-2X/3C 150-185 / NA ESIJ-2X/3C 240-300 / NA ESIJ-2X/3C 25-50 / SA ESIJ-2X/3C 70-120 / SA ESIJ-2X/3C 150-185 / SA ESIJ-2X/3C 240-300 / SA 25-50 70-120 150-185 240-300 Catalog Number Conductor Size Upto 12KV/Plastic One Conductors (Without Armour)
mm ESIJ-3X/1C 16-25 / NA ESIJ-3X/1C 35-70 / NA ESIJ-3X/1C 95-150 / NA ESIJ-3X/1C 185-300 / NA 16-25 35-70 95-150 185-300 Catalog Number
Conductor Size Upto 12KV/Plastic Three Conductors (With Armour)
(With Armour)
mm ESIJ-3X/3C 16-35 / NA ESIJ-3X/3C 50-95 / NA ESIJ-3X/3C 120-185 / NA ESIJ-3X/3C 240-300 / NA ESIJ-3X/3C 16-35 / SA ESIJ-3X/3C 50-95 / SA ESIJ-3X/3C 120-185 / SA ESIJ-3X/3C 240-300 / SA 16-35 50-95 120-185 240-300 Catalog Number Conductor Size Upto 17.5 ,KV/Plastic One Conductor (Without Armour)
mm ESIJ-4X/1C 25-35 / NA ESIJ-4X/1C 50-95 / NA ESIJ-4X/1C 120-185 / NA ESIJ-4X/1C 240-300 / NA 25-35 50-95 120-185 240-300 Catalog Number
Conductor Size Upto 17.5KV/Plastic Three Conductors (Without Armour)
(With Armour)
mm ESIJ-4X/3C 25-35 / NA ESIJ-4X/3C 50-95 / NA ESIJ-4X/3C 120-185 / NA ESIJ-4X/3C 240-300 / NA ESIJ-4X/3C 25-50 / SA ESIJ-4X/3C 70-120 / SA ESIJ-4X/3C 120-185 / SA ESIJ-4X/3C 240-300 / SA 25-35 50-95 120-185 240-300 Catalog Number Conductor Size Upto 36KV/Plastic One Conductors (Without Armour)
mm ESIJ-6X/1C 35-70 / NA ESIJ-6X/1C 95-150 / NA ESIJ-6X/1C 185-400 / NA ESIJ-6X/1C 500-630 / NA 35-70 95-150 185-400 500-630 Catalog Number
Conductor Size Upto 36KV/Plastic Three Conductors (Without Armour)
(With Armour)
mm
ESIJ-6X/3C 35-70 / SA ESIJ-6X/3C 95-150 / SA ESIJ-6X/3C 185-300 / SA 35-70 95-150 185-300 Single core kits contain material for 1 core only. Ferrules are not included in the kits and should be procured separately.
Raychem range of joints include upto 72KV. Please contact ADWAN for CONTROL CABLE JOINTS This range provides heat shrinkable cable joints for multi-core, plastic control cables operating upto 1KV, with armour. Catalog Number Number of Cores Conductor Size mm ECKJ-0017 ECKJ-0018 ECKJ-0019 ECKJ-0020 ECKJ-0021 4-7 8-14 15-21 22-40 41-75 1.0-2.5 1.0-2.5 For multi-pair cables with and without armour and muti core cables without armour. Please contact ADWAN for details. TRANSITION JOINTS Raychem offers a wide range of heat shrinkable transition joint, upto 36KV, for any of the following configurations: -Cables having a different cross sectional areas. -Plastic to paper cables. -Three core plastic or paper cable to three single core plastic or paper cables.
Raychem could also help by designing a transition joint for your specific needs. Please contact ADWAN for details. 04 CABLE TERMINATION & ACCESSORIES LL2I L5,LeI LLL. 4-28 MOTOR CONNECTION KITS MCK heat shrinkable caps replace tape and filler putty methods of insulating connections in motor conduit boxes. Each MCK kit connects a three lead motor. Catalog Number Voltage Rating Feeder Size Lug Length Splice Configuration
mm mm Stub Splice Type V MCK-1V MCK-2V Upto 1 KV Upto 1 KV 2.5-6 4-16 25-95 120-240 44 56 82 133
Catalog Number Voltage Rating Feeder Size Lug Length Splice Configuration
mm mm Stub Splice Type V MCK-6-1V-00 MCK-5-2V-00 Upto 7.2 KV Upto 7.2 KV 6-35 50-120 150-400 127 153 179
Catalog Number Voltage Rating Feeder Size Lug Length Splice Configuration
mm mm Stub Splice Type L
MCK-1L
Upto 1 KV
10-95 120-500
127 210
Catalog Number Voltage Rating Feeder Size Lug Length Splice Configuration
mm mm In-line Splice Type L
MCK-5-1L-00
Upto 7.2 KV
10-120 150-500
153 179
Catalog Number Rectangle Bar Profile Round Bar Diameter Spool Length
(l + t) mm (d) mm
BBIT-25/12-A/U BBIT-40/16-A/U BBIT-65/25-A/U BBIT-100/40-A/U BBIT-150/60-A/U 17-28 28-45 44-67 69-102 102-148 11-20 18-32 28-47 44-72 65-105 30 m 30 m 15 m 15 m 15 m BUS BAR TUBING BBIT and BPTM are heat shrinkable tubings for use on straight or bent bus bars where maximum clearance reduction is required. Ideal for original equipment assembly or in retrofit applications where access to one end is available. Provides insulation upto 36KV and long term reliability even at high continuous operating temperature. Catalog Number Rectangle Bar Profile Round Bar Diameter Spool Length
(l + t) mm (d) mm
BPTM-15/6-A/U BPTM-30/12-A/U BPTM-50/20-A/U BPTM-75/30-A/U BPTM-100/40-A/U BPTM-120/50-A/U BPTM-175/70-A/U 12-18 22-38 36-65 55-95 70-130 90-165 125-235 6.5-12 13.5-25 22-43 33-63 44-86 55-105 80-150 30 m 30 m 30 m 30 m 25 m 25 m 15 m GENERAL PURPOSE TUBING RNF-100 is a flexible, general purpose tubing. Designed for a wide range of applications, RNF- 100 is used extensively for insulation, light weight harness jackets, colour coding, and identification. Available in clear or standard colours. Can be rapidly installed using a variety of heating tools. Catalog Number Application Range Min-Max Dia. Spool Length* 1.2m Length Colour Code Information Colour
mm
RNF-100-3/65-X RNF-100-1/16-X RNF-100-3/32-X RNF-100-1/8-X RNF-100-3/16-X RNF-100-1/4-X RNF-100-3/8-X RNF-100-1/2-X RNF-100-3/4-X RNF-100-1-X RNF-100-1 1/2 RNF-100-2-X RNF-100-3-X RNF-100-4-X 0.6-1.2 0.8-1.6 1.2-2.4 1.6-3.2 2.4-4.8 3.2-6.4 4.8-9.5 6.4-12.7 9.5-19.0 12.7-25.4 19.0-38.0 25.4-51.0 38-76.0 51.0-102.0 300 m 300 m 150 m 150 m 150 m 75 m 75 m 75 m 75 m 30 m 30 m 30 m 15 m 15 m 30 m 30 m 30 m 30 m 30 m 12 m 12 m 0 2 4 6 7 8 8 Bl ack Red Yell ow Bl ue Voil et Grey White Replace X by the colour co de required * MInimum order quantity is spool. XAGA-550 JOINT CLOSURE SYSTEM
XAGA-550 is Heat-shrinkable composite Joint Closure System for environmental and mechanical protection of Joints in the unpressurised Copper Telephone net- works. It is suitable for aerial, buried and ducted applications and has a range of closures to suit all cable sizes. CABLE TERMINATION & ACCESSORIES LL2I L5,LeI LLL. 04 4-29 XAGA 1000 Joint closure system for pressurised copper telephone networks
High performance heat-shrinkable closure for pressurised applications Suitable for aerial, buried and ducted applications Composite material provides high mechanical strength Range of closures to suit all cable sizes Applicable for polyethylene and metal jacketed cables Pre-installed valve for pressure access and measuring Suitable for use with all standard connector systems Up to 4 cables out at each end Wraparound closure suitable for both maintenance and new construction Interchangeable air valve/connector Hot melt adhesive designed specifically for pressurised closure applications BOKT kit contenct