Anda di halaman 1dari 4

CLLI CLLI I

INSIDE NSIDE
CLLI SF9512- SD-4C SD4Ccu Trinity SF9812DSL SCSF-9512 SP9201 SLAN CLLI SD-4C SF9512CU (TM- SP9201- DCJ-cu DCJ-cu+E DELAY-
Model DSL or ARD +ARD or DSL I-T Pack or ARD ARD -DAF 1236 Model 1278 MARCONI) EXD 24V-1A/2A (12V-2A) OFF- SW
RRP @ RM 79.00 89.00 108.00 123.00 89.00 53.00 43.00 39.00 RRP @ RM 89.00 93.00 29.00 29.00 29.00 43.00

CLLI – ICT-series CLLI – ICT-series


SF9512 CLLI model: Trinity I-T Pack (MS4+3) Trinity IT-pack
CLLI model: SF9512-DSL / D / AR
13A-plug + 1.5M AC-cable / 13A socket-outlet + 13A-plug + 2M cable / 13A socket-outlet x4 +
RJ-11 (IN-OUT) 3x2-pin outlets
Max. power: 1KW / 5A Max. power: 2KW / 10A
Type approval ref: by request Type approval ref: by request
Applications: Applications:
To create safe-island connected to 2-external To create safe-island connected to 2-external
links – Power-line & Tel-line links – Power-line & Tel-line
• SF9512-DSL +E for Broadband ADSL modem • SF9512-DSL +E for ADSL modem
• SF9512-AR-D for FAX / Cordless-phone • Optional fused version for 5A or 10A
Front & Back of IT-pack
< Same 3-versions without Power-section are
available as SP9201 series > Typical installation – ICT series
From Telco
For Tel-line + Local-Area-Network:
• SD-4Ccu(+AR-D) for Network-PC / FAX / SD-4Ccu(+DSL)
Cordless-phone / printer (3-external links) for Broadband
• SD-4Ccu(+DSL) for broadband-PC + Network Micro-
+ LAN filter

CLLI model: SP9201-DAF 1&2 = DSL in or


out 1
ADSL RJ-11 (IN-OUT) + RJ-11 out for ANALOG 2 3 SF9512-D
phone / FAX 3 = out to
1 ANALOG phone MDSC0039 + SF9512-DSL Safe-island
Type approval ref: by request SP9201-DAF
Applications: or FAX #2
2 3
• 3-in-1 CLLI for Telephone-line + DSL + Micro Auto
filter Dialer FAX-machine
SP9201-DAF DSL Wi-Fi Router-
• Direct replacement for Micro-filter + functions Modem Switch or
as Lightning Isolator for telephone line. Cordless-phone
ALARM PANEL
(Detailed protection Safe-island
Important: available by #3
This CLLI enhances high-speed DSL & must be request) PC + Monitor
+ PRINTER ++
used together with MDSC0039 or similar power CLLI
Safe-island #1 (Details for Network
that provides an EARTH terminal. cable by request)

Without correctly creating a safe-island, CLLI cannot be effective!


1. Each EARTH-wire of cable-CLLI must be connected to the CLLI at power supply. Safe-island #4 CLLI-LAN series Safe-island #5
2. Partial protection is NOT effective! We discourage using any CLLI, if you do not SD-4Ccu(+DSL)
intend to fully follow our suggestions! But please beware of IMITATIONS!
SD-4C
3. Tech-support hot-line: 012-771 8225 / Reseller Assistance: 012-773 8225 PC-SETUP
+ PC-SETUP
Specs, Prices, Versions & Conditions are subject to change without notice. DSL-MODEM +
Kindly refer to www.cal-lab.com for latest info. Before you make any purchase, please + NETWORK
make sure you know the model or version as we have NO REFUND policy. NETWORK
Non-tampered CLLI can be exchange-replaced @ RM25 or less, for life (LLSWA)
Call / FAX: 06-9517680 or 03-77268680 Email: callab@callab.com.my PLC-CLLI series for PLC-adapters are also available by request
CLLI I CLLI
NSIDE INSIDE
CLLI SFTV9622 SFTV9622 STV9511 Trinity MD-FC MDSC- CLLI SL-AR +E SL9602 MD-3Phase MD-4Ccu MD-4Ccu MD-4Ccu CAREFREE
Model -FC -FC-MS2+3 AV-pack 0039FC Model 1.5A or 3A -F (2A) 24V-2A +24V-2A (CB-5V-1A) LITE DIY
RRP @ RM 99.00 113.00 79.00 143.00 33.00 63.00 RRP @RM 89.00 79.00 53.00 43.00 43.00 53.00 43.00

CLLI Home-Entertainment series CLLI Home-Entertainment series


CLLI model: SFTV9622FC-MS2+3 Also available: CLLI model: Trinity A-V Pack (MS3+3)
13A-plug + 1.5M cable / 13A socket-outlet x2 + 3x2- single-outlet 13A-plug + 2M cable / 13A socket-outlet x3
pin outlets versions + 3x2-pin outlets
SFTV9622FC
Max. power: 2KW / 10A &
Max. power: 2KW / 10A
Type approval ref: by request SFTV9822FC Type approval ref: by request Trinity A-V Pack
Applications: Applications:
To create a safe-island for equipment setup SFTV9622FC-MS2+3 To create a safe-island for equipment setup
linked to 4-external sources - power + linked to 4-external sources - power +
Telephone-line + TV-Antenna + Satellite cable Telephone-line + TV-Antenna + Satellite cable

• For Satellite decoder +TV +HI-FI setup. • For Satellite decoder + TV +HI-FI setup
• Also available a version with single power • Isolation circuits at all out-puts
outlet to be used with multiple trailing sockets • Optional fused version for 5A or 10A
• The Tel-line isolator is for analog phone / FAX
or dial-up modem only (not for DSL).
Typical installation – Home-Entertainment series
From Telco
CLLI model: MDSC0039-FC
A-V Pack
13A-plug + 1.5M cable / 13A socket-outlet + F- For user-safety, Or
Connector for Satellite cable SP9201-DAF SFTV9622FC
Max. power: 2KW / 10A must be grounded Or MD-series
1 correctly.
Applications: 2 3
Used to create a safe-island for equipment MDSC0039-FC
setup connected to 2-external links – Power +
Satellite cable

• For Satellite Decoder without Tel-line & TV- Add SP9201- Sat.- Hi-Fi Safe-zone
antenna connections DAF or Micro- Decoder Amplifier Or
• Add MDTV or SP-series, if necessary. filter before Safe-island
• Can also be used for IDU & ODU of connecting to Created by
Satellite
Communications equipment. TV + CLLI
Decoder, if
sharing ADSL- DVD-player +
line ++
Without correctly creating a safe-island, CLLI cannot be effective!
4. Each EARTH-wire of cable-CLLI must be connected to the CLLI at power supply.
5. Partial protection is NOT effective! We discourage using any CLLI, if you do not
PLC-CLLI +HI-FI
intend to fully follow our suggestions! But please beware of IMITATIONS!
6. Tech-support hot-line: 012-771 8225 / Reseller Assistance: 012-773 8225 NILI-PLC-GBH
PLC-adapter PLC-adapter
Specs, Prices, Versions & Conditions are subject to change without notice.
Safe-island #1 AV-centre Room
Kindly refer to www.cal-lab.com for latest info. Before you make any purchase,
To equipment that setup Video Hi-Fi ++
please make sure you know the model or version as we have NO REFUND policy.
generates RF-noise or Video Hi-Fi ++ setup
Non-tampered CLLI can be exchange-replaced @ RM25 or less, for life (LLSWA)
Call / FAX: 06-9517680 or 03-77268680 Email: callab@callab.com.my dampens DATA-signal Safe-island #2 Safe-island #3
What Is EPSM? • When both of your feet are on the EPSM – if there was a high voltage
present, it would not conduct to your body because you are standing on
(Equal Potential Safety Mat) INSULATING-material, gradually shifting to be at equal-potential.
Patent-pending, filed by Paul Chang – Chief Inventor of CAL-LAB • As soon as you are on the EPSM, it would gradually equalize your body-
potential to that of the refrigerator’s or any other equipment that are also on
Brief Background – why is EPSM a life-saver? the same EPSM (forming one safe-island).
A woman died when she grabbed the handle of a refrigerator, just as a lightning • Because, once you are on the EPSM, you are at Equal Potential with ALL
discharge was downloaded onto the EARTH-connection leading to the refrigerator! equipment or conductors on it, you have an environment as safe as that of
Her sister who was nearby was injured although she was not touching anything. a bird perching on a high-tension cable.

An analysis into the forces involved would have revealed that the ELCB or How can EPSM be successful & effective?
modern-day RCCD could not have made any difference in this case, because
• It must be kept dry at all times
the Earth-VOLTAGE-rise or Earth-POTENTIAL-rise at the refrigerator handle
• It must be connected to the same EARTH-point as the refrigerator handle
was not caused by the power supply lines. Switching off the power supply
• You must not touch the refrigerator handle before both your feet are on the
would have no difference on the outcome!
EPSM
• Once on the EPSM, you must not touch any item that is not on the same
The only way she could have been saved would be to put her in a situation
EPSM.
or an environment like a bird perched on a 132KV high-tension cable! The bird
is not affected by the tremendously high voltage because the bird is at EQUAL • A correctly set up PC work-station will also become a safe-island.
POTENTIAL (no voltage-difference) with the cable (therefore no current
flowing through its body). A typical SAFE-island setup with CLLI + EPSM
Danger from STEP-potential Difference is avoided
EPSM (Equal Potential Safety Mat) creates exactly the same SAFE-
environment for you at a chosen area in your home or work-place –
such as kitchen, computer work-area or work-station. So that you are
always safe from electricity-leakage or lightning discharge!

How does EPSM work?


The Bird-analogy
• When the bird approached the high-tension cable, whatever STATIC-
voltage-potential it was at would be shifted to that of the high-tension cable’s,
gradually – because it was not touching another cable
• If the bird’s wings were spread between two of the high-tension cables,
it would be cooked immediately
• The bird was safe at more than 100,000volts because it was not touching
another cable – hence there was no potential difference to conduct current
through its body.

The EPSM
• There must not be any substantial voltage difference between your left
foot and your right foot (step-potential) when you step onto the EPSM –
hence the EPSM must present a floating platform with immunity to at least
few thousand volts, so that when one of your feet lands on it, it does not More info in www.cal-lab.com or Contact us:
conduct any current. Phone - +6012 771 8225 / +6019 2311829
Email – callabhq@gmail.com / callabkl@gmail.com / callab@callab.com.my
Related Related
CLLI CLLI
Model PLC-WM2 MD-PLC-2 MD-PLC-2(GBH) MD-PLC-3 PLC-WP3 Model NILI-PLC-1 MD-SC-NIF-1 SC-NIF-1 SC-NIF-1(+E) PLCI-MODULE NILI-WP-1
RRP @RM 113.00 118.00 123.00 143.00 143.00 RRP @RM 99.00 73.00 63.00 73.00 63.00 93.00

CLLI BPL-PLC Series (Patent pending) Why Do You Need PLC-Cal-Lab Lightning Isolators for
LIGHTNING ISOLATORS For Broadband-over-Power-Line set-up Broadband-over-Power-Line.
Typical Installation for stand-alone PLC-setup 2-reasons why every PLC-setup needs a PLC-CLLI
• PLC adapters & connected equipment are not cheap – but they are
PLC-adapter – plug here What can be plugged into this? prone to lightning & surge damages.
(Max. 2000W – UK or Univ. outlet) • Our PLC-CLLI is effective! Not only all interconnected equipment can
PC-setup - forming one SAFE-island
share one wall-outlet & be safe from lightning strikes, but at the same
where every interconnected device draws
power from it. (no link to another setup) time, PLC connection-rate is enhanced!
Customized version or Module:
Available by special order only Very Important Notes:
1. A NILI-PLC-Twin is needed at each PLC-adapter setup.
Specifications:
2. NILI-PLC may be used to reduce RF-noise from being injected or to
Model NILI-PLC (1, 2 or 3 outlets) MD-PLC (1, 2 or 3 outlets)
prevent data signal from being weakened by other equipment.
Working Voltage 100~250Vac (optional) 100~250Vac (optional)
3. In simulation tests on Feb 17 2009, the connection-rate of HomePlug-AV-
Let Through Voltage 275Vrms 275Vrms
200Mbps improved from less than 30Mbps to more than 150Mbps.
Static Potential Limit 275Vrms 275Vrms
4. With PLC-CLLI, a vacuum cleaner + a power-drill sharing supply from
Isolation by Over-current or over-voltage Over-current or over-voltage
the same wall outlet with the PLC=adapter – had no negative effect!
Filter Lo-pass + EMI + E2 Lo-pass + EMI + E2
5. Performance-enhancement & Lightning isolation features of PLC-CLLI
Plug & Socket +10cm AC cord or Wall-P&S +1.5M AC cord +UK or UNIV-outlet can be cost-effectively added or retro-fitted into PLC-adapters.
PLC-WP-1 or -3 MD-PLC-2 or -3 (+E)
How to use PLC-CLLI in In-premises setups
NILI-PLC-1
Short AC cord
For cleaner
:Where Access is via DSL modem
Power-line
SP9201-DSL
or SP9201- PLC-adapter
PLC-adapter DAF
NILI-PLC-1 PLCI-MODULE
Modem-
Router
BPL0801T BPL0801T
+E +HI-FI PC-setup
PC-setup Monitor or
Monitor Video Hi-Fi ++
Printer ++
PLC- Safe-island #2
• CLLI are sold with Lifetime Service Warranty – see LLSWA Safe-island #1 adapter
• Correct installation is vital for equipment & USER safeties!
• Terms & Conditions in WARRANTY CARD & Thank-you note. NILI9920-PLC
• Technical Assistance / Important Info in: www.cal-lab.com BPL0801T
PC-setup
SPECS, PRICES & CONDITIONS subject to change. Refer to: www.cal-lab.com Safe-island #4 Monitor
For help, call / FAX: 06-9517680 / 03-7726 8680 Email: callab@callab.com.my Printer ++
To equipment that
Service centre: HQ – 30 Lrg. Kurau 9, Tmn Sg Abong, 84000 Muar, Johor, Malaysia.
generates RF-noise or
Non-tampered & lightning-damaged CLLI can be exchanged @ RM25 or less! Safe-island #3
Tech-assist: 012-771 8225 / Reseller-assist: 012-773 8225 dampens DATA-signal

Anda mungkin juga menyukai