APPLICATION otes N
NEBB AVR Type Parallel Droop Operation Compounding Circuit Current/Voltage Output
SF2 No No
SF2a Yes No
SF2 b Yes No
DECS-200 mounted in a cabinet and equipped with an MVC 300 (manual voltage control) to provide an additional manual back up device.
Option 2
The second is a complete conversion of the brushless system to a static operation. This was done by removing the excitation system Figure 3: Option 2 - Complete and associated conversion of the brushless system to a compound circuits, static operation via Basler cabinet including the exciter. In order to meet space requirements, a doublesided cubicle was designed to accommodate control and power components in one single-door panel.
became its standard replacement both for new and renovation equipment. They were used primarily in brushless exciter applications where the exciter was controlling the main field of the generator. These AVRs generally required several external modules to provide exciter diode monitoring, manual control and other features. Nowadays the DECS-200 offers a complete solution Figure 5: Basler replaces the aging to cater to the regulator with a DECS-200 on a replacement of standard mounting plate these AVRs in one package or in dual application with bumpless transfer from the main operating unit to its back up AVR. The Basler proposed renovation solution is a standard mounting plate generally sized or adapted to meet the space previously taken by the GX AVR. The DECS-200 and DECS-400 offer superior functionalities and capabilities that enables users to extend the life span of generators and better protect them from harmful conditions. Table 2 on the next page summarizes these additional features. Visit www.basler.com and download more information on Basler's Compact Digital Pre-packaged AVR Mounting Plate Solutions. You also can download Bulletin SZM for details on Baslers DECS-200 and Bulletin SZF for more information on the features of the DECS-400. You can also access product documentation and Application Notes on the web site. To discuss your specific application, consult the Basler factory at (618) 654-2341.
Figure 4: GX 300 and GX 500 were replacements for NEBB voltage regulators
FUNCTIONS AVR CONTROL FIELD CURRENT REGULATION CONTROL MODES FIELD VOLTAGE REGULATION VAR/PF CONTROL PARALLEL COMPENSATION AUTO-TRACKING BETWEEN CONTROL MODES AUTO-TRACKING WITH OPTIONAL UNIT UNDER/OVER EXCITATION LIMITING STATOR CURRENT LIMITING GENERATOR PROTECTION EXCITER DIODE MONITOR UNDERFREQUENCY COMPENSATION OR VOLT/HZ LIMITER GENERATOR BACK UP PROTECTION Field Overvoltage Field Overcurrent Generator Overvoltage Generator Undervoltage Loss of Field Loss of Sensing Voltage INSTRUMENTATION OSCILLOGRAPHY / EVENT RECORDING GENERATOR PARAMETERS METERING TRENDING / LIVE MONITORING COMMUNICATION PORTS RS485 RS232 Ethernet
DECS-200 / DECS-400 YES YES DECS 400 YES YES YES YES YES YES YES YES
GX 300 YES
EXTERNAL MODULE EXTERNAL MODULE YES NO NO EXTERNAL MODULE NO YES YES YES YES NO
EXTERNAL MODULE EXTERNAL MODULE UNDERFREQUENCY UNDERFREQUENCY COMPENSATION COMPENSATION ONLY ONLY
YES
NO
NO
NO NO NO
NO NO NO
NO
NO
P .A.E. Les Pins, 67319 Wasselonne Cedex FRANCE Tel +33 3.88.87.1010 Fax +33 3.88.87.0808 e-mail: franceinfo@basler.com No. 59 Heshun Road Loufeng District (N), Suzhou Industrial Park, 215122, Suzhou, P .R.China Tel +86(0)512 8227 2888 Fax +86(0)512 8227 2887 e-mail: chinainfo@basler.com 55 Ubi Avenue 1 #03-05 Singapore 408935 Tel +65 68.44.6445 Fax +65 65.68.44.8902 e-mail: singaporeinfo@basler.com
Route 143, Box 269, Highland, Illinois U.S.A. 62249 Tel +1 618.654.2341 Fax +1 618.654.2351 e-mail: info@basler.com
www.basler.com
EX-NEBB (7/10)