Anda di halaman 1dari 8

BCI184G - Technical Data Sheet

BCI184G
SPECIFICATIONS & OPTIONS
TERMINALS & TERMINAL BOX Standard generators are 3-phase reconnectable with 12 ends brought out to the terminals, which are mounted on a cover at the non-drive end of the generator. A sheet steel terminal box contains the AVR and provides ample space for the customers' wiring and gland arrangements. It has removable panels for easy access.

STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000, VDE 0530, NEMA MG1-32, IEC34, CSA C22.2-100, AS1359. Other standards and certifications can be considered on request. VOLTAGE REGULATORS

SHAFT & KEYS SX460 AVR - STANDARD With this self excited control system the main stator supplies power via the Automatic Voltage Regulator (AVR) to the exciter stator. The high efficiency semiconductors of the AVR ensure positive build-up from initial low levels of residual voltage. The exciter rotor output is fed to the main rotor through a three phase full wave bridge rectifier. This rectifier is protected by a surge suppressor against surges caused, for example, by short circuit. AS440 AVR With this self-excited system the main stator provides power via the AVR to the exciter stator. The high efficiency semi-conductors of the AVR ensure positive build-up from initial low levels of residual voltage. The exciter rotor output is fed to the main rotor through a three-phase full-wave bridge rectifier. The rectifier is protected by a surge suppressor against surges caused, for example, by short circuit or out-of-phase paralleling. The AS440 will support a range of electronic accessories, including a 'droop' Current Transformer (CT) to permit parallel operation with other ac generators. WINDINGS & ELECTRICAL PERFORMANCE All generator stators are wound to 2/3 pitch. This eliminates triplen (3rd, 9th, 15th ) harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads. The 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitches, when in parallel with the mains. A fully connected damper winding reduces oscillations during paralleling. This winding, with the 2/3 pitch and carefully selected pole and tooth designs, ensures very low waveform distortion. All generator rotors are dynamically balanced to better than BS6861:Part 1 Grade 2.5 for minimum vibration in operation. Two bearing generators are balanced with a half key.

INSULATION/IMPREGNATION The insulation system is class 'H'. All wound components are impregnated with materials and processes designed specifically to provide the high build required for static windings and the high mechanical strength required for rotating components.

QUALITY ASSURANCE Generators are manufactured using production procedures having a quality assurance level to BS EN ISO 9001. The stated voltage regulation may not be maintained in the presence of certain radio transmitted signals. Any change in performance will fall within the limits of Criteria 'B' of EN 61000-6-2:2001. At no time will the steady-state voltage regulation exceed 2%.

NB Continuous development of our products entitles us to change specification details without notice, therefore they must not be regarded as binding. Front cover drawing typical of product range.

BCI184G
WINDING 311
CONTROL SYSTEM A.V.R. VOLTAGE REGULATION SUSTAINED SHORT CIRCUIT INSULATION SYSTEM PROTECTION RATED POWER FACTOR STATOR WINDING WINDING PITCH WINDING LEADS STATOR WDG. RESISTANCE ROTOR WDG. RESISTANCE EXCITER STATOR RESISTANCE EXCITER ROTOR RESISTANCE R.F.I. SUPPRESSION WAVEFORM DISTORTION MAXIMUM OVERSPEED BEARING DRIVE END BEARING NON-DRIVE END 1 BEARING WEIGHT COMP. GENERATOR WEIGHT WOUND STATOR WEIGHT WOUND ROTOR WR INERTIA SHIPPING WEIGHTS in a crate PACKING CRATE SIZE 167 kg 64.3 kg 55.98 kg 0.22 kgm 2 172 kg 84 x 59 x 75 (cm) 50 Hz TELEPHONE INTERFERENCE COOLING AIR VOLTAGE SERIES STAR VOLTAGE PARALLEL STAR VOLTAGE SERIES DELTA kVA BASE RATING FOR REACTANCE VALUES Xd DIR. AXIS SYNCHRONOUS X'd DIR. AXIS TRANSIENT X''d DIR. AXIS SUBTRANSIENT Xq QUAD. AXIS REACTANCE X''q QUAD. AXIS SUBTRANSIENT XL LEAKAGE REACTANCE X2 NEGATIVE SEQUENCE X0 ZERO SEQUENCE T'd TRANSIENT TIME CONST. T''d SUB-TRANSTIME CONST. T'do O.C. FIELD TIME CONST. Ta ARMATURE TIME CONST. SHORT CIRCUIT RATIO 380/220 190/110 220/110 31.3 1.729 0.166 0.122 0.864 0.188 0.070 0.155 0.074 THF<2% 0.095 m/sec 200 cfm 400/231 200/115 230/115 31.3 1.560 0.150 0.110 0.780 0.170 0.063 0.140 0.067 415/240 208/120 240/120 31.3 1.449 0.139 0.102 0.725 0.158 0.059 0.130 0.062 440/254 220/127 254/127 27.5 1.467 0.141 0.104 0.734 0.159 0.059 0.132 0.063 416/240 208/120 240/120 35 1.938 0.199 0.124 0.957 0.211 0.078 0.186 0.083 SELF EXCITED STANDARD SX460 1.0 % OPTIONAL AS440 1.0 %

SELF EXCITED MACHINES DO NOT SUSTAIN A SHORT CIRCUIT CURRENT CLASS H IP23 0.8 DOUBLE LAYER CONCENTRIC TWO THIRDS 12 0.214 Ohms PER PHASE AT 22C SERIES STAR CONNECTED 0.83 Ohms at 22C 22 Ohms at 22C 0.115 Ohms PER PHASE AT 22C BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0% 2250 Rev/Min BALL. 6309 - 2RS. (ISO) BALL. 6306 - 2RS. (ISO) 2 BEARING 170 kg 64.3 kg 56.76 kg 0.22 kgm 2 180 kg 84 x 59 x 75 (cm) 60 Hz TIF<50 0.119 m/sec 250 cfm 440/254 220/127 254/127 37.5 1.857 0.190 0.119 0.916 0.202 0.075 0.179 0.080 460/266 230/133 266/133 37.5 1.699 0.174 0.109 0.838 0.185 0.069 0.163 0.073 480/277 240/138 277/138 37.5 1.560 0.160 0.100 0.770 0.170 0.063 0.150 0.067

REACTANCES ARE SATURATED

VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATED 0.024 s 0.006 s 0.55 s 0.007 s 1/Xd

50 Hz

BCI184G
Winding 311 THREE PHASE EFFICIENCY CURVES

60 Hz

BCI184G
Winding 311 THREE PHASE EFFICIENCY CURVES

BCI184G
Winding 311 Locked Rotor Motor Starting Curve

50
30

Hz

346

380

400

415

440

25
PER CENT TRANSIENT VOLTAGE DIP

20

15

10

0 0 10 20 30 40 50 60 70
LOCKED ROTOR kVA

60
30

Hz

380V

416V

440V

460V

480V

25

PER CENT TRANSIENT VOLTAGE DIP

20

15

10

0 0 10 20 30 40 50 60 70 80 90
LOCKED ROTOR kVA

BCI184G

Page left blank intentionally

BCI184G
Winding 311 / 0.8 Power Factor RATINGS
Class - Temp Rise Cont. F - 105/40C 380 190 220 400 200 230 29.0 23.2 86.7 26.8 415 208 240 29.0 23.2 87.0 26.7 440 220 254 25.5 20.4 87.2 26.6 Cont. H - 125/40C 380 190 220 31.3 25.0 85.7 29.2 400 200 230 31.3 25.0 86.2 29.0 415 208 240 31.3 25.0 86.4 29.0 440 220 254 27.5 22.0 86.7 28.9 Standby - 150/40C 380 190 220 32.5 26.0 85.3 30.5 400 200 230 32.5 26.0 85.8 30.3 415 208 240 32.5 26.0 86.1 30.2 440 220 254 28.6 22.9 87.3 26.2 Standby - 163/27C 380 190 220 33.0 26.4 85.2 31.0 400 200 230 33.0 26.4 85.7 30.8 415 208 240 33.0 26.4 86.0 30.7 440 220 254 29.0 23.2 87.2 26.6 Series Star (V) Parallel Star (V) Series Delta (V)

50
Hz

kVA 29.0 kW 23.2 Efficiency (%) 86.4 kW Input 26.9

60
Hz

Series Star (V) Parallel Star (V) Series Delta (V)

416 208 240

440 220 254 34.4 27.5 87.0 31.6

460 230 266 34.4 27.5 87.3 31.5

480 240 277 34.4 27.5 87.5 31.5

416 208 240 35.0 28.0 86.3 32.4

440 220 254 37.5 30.0 86.3 34.8

460 230 266 37.5 30.0 86.7 34.6

480 240 277 37.5 30.0 87.0 34.5

416 208 240 36.3 29.0 86.0 33.8

440 220 254 38.8 31.0 86.0 36.1

460 230 266 38.8 31.0 86.4 35.9

480 240 277 38.8 31.0 86.8 35.8

416 208 240 36.9 29.5 85.9 34.4

440 220 254 40.0 32.0 85.7 37.3

460 230 266 40.0 32.0 86.2 37.1

480 240 277 40.0 32.0 86.5 37.0

kVA 31.3 kW 25.0 Efficiency (%) 87.1 kW Input 28.7

DIMENSIONS

Barnack Road Stamford Lincolnshire PE9 2NB Tel: 00 44 (0)1780 484000 Fax: 00 44 (0)1780 484100