Conjunto de Manobra e Controle de Baixa Tenso Low Voltage Switchgear and Controlgear
Transformador Mdia Tenso Medium Voltage Transformer Centro de Controle de Motores Baixa Tenso Motor Center Control Low Voltage Conjunto de Manobra Mdia Tenso Medium Voltage Switchgear Chave de Transferncia e Paralelismo Paralleling Switchgear Gerador Generator Transformador Baixa Tenso Low Voltage Transformer Painel de Controle e Automao Low Voltage Switchgear Gerador Auxiliar Roll-up Generator Monitorao Monitoring
RPP Remote Power Panel RPP Chaves Estticas Remote Power Panel Static Switch Servidores UPS Modular Severs Modular UPS PDU Power Distribution Unit
IFS Wiring Closet UPS UPS Auto-Tie UPS Static Auto-Tie UPS
Baterias Batteries
Nossa fbrica local e a equipe de Engenharia e Servios em Sistemas Eltricos mantm o nvel de qualidade e agilidade no atendimento. Local Eaton facilities and engineering services help support service level agreements and disaster recovery.
Electrical Group - PCSO - Diviso Amrica Latina Electrical Group - PCSO - Latin America Division
Mexico Plant
Venezuela ACE
Brazil - So Paulo
Ware House & Logistic Center
EATON CORPORATION
Famlia Gemini
EATON CORPORATION
Famlia Gemini
Caractersticas
Characteristics
Segurana Pessoal
Total separao interna de todas unidades funcionais Mnima proteo do invlucro: IP31, outros graus de proteo disponveis quando solicitados. Medidas para limitar as consequncias de uma falha interna em uma unidade de sada. A proteo interna, incluindo compartimentos abertos, do conjunto IPXXB. Intertravamento automtico da porta de todas as sees de alimentadores previnem o acesso ou remoo quando a chave esta na posio LIGADA Fusveis dentro da partida do motor podem ser somente substituidas quando a unidade extravel esta totalmente removida. Acesso aos cabos das unidades atravs de compartimentos segregados das gavetas e barramentos. Guilhotinas opcionais podem ser montadas para proteger o barramento de distribuio quando as unidades extraveis esto removidas Conexes seguras dos cabos so viveis durante condies normais de operao dos barramentos. O compartimento de entrada de cabos pode ser fornecido de forma a estar livre de presena de tenso.
Personal safety
Full internal separation of all functional units. Enclosure protection IP31 minimum, higher ratings are available when required. Features to limit the consequences of an internal fault in outgoing units. Internal protection, including for opened switchgear compartments, is IPXXB, (maintained even when drives removed). Automatic door interlocking of all outgoing feeder sections prevents access or removal when the switch is in the ON position. Fuse-links within motor starters can only be replaced when the drawout unit is fully removed. Access to cable termination of a drawout unit is possible through a dedicated compartment segregated from units and busbars. Shutters are mounted to guard the distribution busbars when drawers are removed. Safe connection of outgoing cables is feasible under live conditions of the busbar. The cable entry compartment can be supplied as voltage free.
Fault-free zone
Additional options to comply with the requirement of a fault-free zone between incomer and outgoing protection are: Possibilit of full insulation Possibilit of epoxy powder insulated bars for distrbution busbars. Epoxy powder insulated bars for incomer and buscoupler busbars.
Flexibilidade do sistema
Compartimentos para unidades extraveis podem ser modificados no campo. Conexes dos cabos s unidades extraveis podem ser realizadas com barramento vertical energizado. Faixa de tamanhos padronizados de cubculos para acessos frontal e traseiro, entradas / sadas superiores e inferiores de cabos Cubculos projetados para aplicaes com arranjos do conjunto em ngulo de 90 graus. At 14 sadas por coluna. Vasta faixa de opes, tais como partidas suaves, inversores de frequencia, CLPs, chaves de transferncias, controle do fator de potncia, filtros de harmnicas, etc. Conjuntos com as funes integradas de CCM e CDC.
System flexibility
Compartments for drawout units can be modified in the field. Cable connection to drawout units can be accomplished under live conditions of distribution bars. Standard range of cubicle sizes for front/rear connection, bottom or top entry of cables. Corner cubicle for angular mounting. Up to 14 outgoing units per cubicle. Wide range of options, such as soft starters, frequency converters, PLC units and changeover equipment, units for power factor improvement, harmonic filtration,etc. Assemblies with combined motor control and high current distribution functions.
Confiabilidade Operacional
Testado no CEPEL (TTA e PTTA). Separao interna, em conformidade com IEC 60439-1, ABNT NBR IEC 60439-1 Forma 3a, Forma 3b e Forma 4b. Barramento de distribuico vertical totalmente delimitado por uma cmara de barramento isolado Segregao continua dos pinos de contatos principais da unidade extravel, prevenindo falhas entre fase-fase e fase-terra. Barramento vertical de distribuio com arranjo das barras de fase para aumento da refrigerao e confiabilidade. Arranjo dos contatos das garras de fora das unidades extraveis impedem a solda do barramento e o risco da repulso do contato durante um curto circuito. A utilizao sistemtica de torqumetro durante a montagem garante a confiabilidade das conexes eltricas. O projeto, engenharia e montagem da Famlia Gemini so realizados atravs de sistemas de gerenciamento da qualidade ISO 9001 alm do sistema de gerenciamento ambiental ISO 14001.
Operational reliability
CEPEL tested (TTA and PTTA). Internal separation is standard, complying with IEC 60439-1, NEN 60439-1 and BSEN 60439-1 Form 4a type 2, Form 4b types 3, 6 and 7. Vertical distribution busbars are completely enclosed by an insulated busbar chamber. Segregation is continued at the main contact pins of the drawout units, preventing phase-to-phase and phase-toearth faults. Vertical distribution busbars with phase arrangements for increased cooling and reliability. Main isolating scissor-shaped contacts between distribution busbars and drawout units prevent contact wear or welding to busbars and counteract the risk of contact repulsion under short-circuit conditions. The systematic use of torque wrenches during assembly guarantees reliable electrical connections. The design, engineering and assembly of the Gemini system is carried-out within an ISO 9001. Quality Management System and a ISO 14001 Environmental Management System.
Manuteno
Opes para acesso frontal ou traseiro dos cabos de conexo. O uso de matria prima e de componentes de alta qualidade reduzem a manuteno a nveis mnimos. Acessibilidade aos barramentos verticais e horizontais com o equipamento desenergizado.
Maintenance
Options for front or rear cable connections access. The use of high-grade materials and components, reduces maintenance to a minimum. Accessibility of vertical and horizontal busbars with power turned off.
EATON CORPORATION
Famlia Gemini
EATON CORPORATION
Famlia Gemini
Gemini Conjunto de Manobra e Controle de BT Painis de distribuio e comando TTA/ PTTA (NBR IEC 60439-1)
A Famlia Gemini de painis eltricos composta por Conjuntos de Manobra (Gemini Px) e de Controle (Gemini Cr) projetados, desenvolvidos e testados pela Eaton Brasil conforme norma NBR IEC 60439-1. A concepo deste produto baseada nos mais recentes desenvolvimentos e filosofias adotadas atualmente ao redor do mundo.
Gemini Px
Conjunto de Manobra CDC Switchgear
Entrada: Dimenses bsicas: - Altura: 2340 mm - Largura: 800 / 900 mm - Profundidade: 600 (sadas) / 915 mm (entrada com disjuntor Magnum IEC)
n
Incoming: Basic column dimensions: - Height: 2340 mm. - Width: 800 / 900 mm. - Depth: 600 (outgoings) / 915 mm (Incomer with Magnum IEC CB).
n
Gemini Cr
Conjunto de Controle CCM Controlgear
Invlucro metlico. Barreiras metlicas entre sees verticais e unidades de entrada/sada. Unidades fixas, removveis e extraveis. Guilhotinas metlicas para demarrador extravel. Guilhotinas isolantes para disjuntores de potncia extraveis (Magnum IEC). Mximo de 14 (catorze) unidades extraveis de tamanho 1X (gavetas) por coluna vertical do CCM - Baixa Tenso. Tamanho 1X: Demarrador de Partida Direta No Reversvel at 60A ou Alimentador at 160A. Tamanho 2X: Demarrador de Partida Direta No Reversvel at 115A ou Alimentador at 250A. Tamanho 3X: Demarrador de Partida Direta No Reversvel at 200A ou Alimentador at 400A. Tamanho 4X: Demarrador de Partida Direta No Reversvel at 250A ou Alimentador at 630A. Maximo de 3 (trs) unidades extraveis de disjuntor de potncia (Magnum) por coluna vertical de conjunto de manobra de BT. Conectores de potncia de 200A e 400A para gavetas extraveis do CCM. Disjuntor Caixa Moldada fixo ou com plug-in para entrada do CCM. Disjuntor de potncia (Magnum) fixo ou extravel para entrada do CCM. Disjuntor de potncia extravel, Magnum IEC modelos Narrow e Standard Unidades fixas de Partidas Suaves e Inversores de Freqncia. Trs posies definidas para as unidades extraveis: conectado, teste e extrado. Seccionamento duplo das garras de potncia nas unidades extraveis. Extrao dupla (circuito de controle e potncia) nas unidades extraveis. Tomada de controle de 25 pontos com conexo automtica para gavetas extraveis do CCM. Tomada de controle com conexo automtica para disjuntores de potncia (Magnum). Sistema opcional de movimentao (extrao / insero) da gaveta do CCM com a porta do compartimento fechada. Cantoneiras de iamento para cada unidade de transporte. Acessos para conexo de cabos: superior ou inferior. Compartimento de cabos com 250mm de largura para as colunas do CCM.
n n n n
Metallic enclosure. Metallic barriers between vertical sections and incoming / outgoing units. Draw-out, removable and fixed units. Metallic shutters for draw-out starter units Isolating shutters for draw-out Power Circuit-breakers (Magnum IEC). Maximum of 14 (fourteen) draw-out 1X size units (buckets / wrappers) per vertical column of LV MCC. Size 1X: 60A FVNR / DOL starter or 160A feeder. Size 2X: 115A FVNR / DOL starter or 250A feeder. Size 3X: 200A FVNR / DOL starter or 400A feeder. Size 4X: 250A FVNR / DOL starter. Maximum of 3 (three) draw-out units (Magnum) per vertical column of LV SWGR. Power plugs for buckets / wrappers (MCC) with 200A and 400A capacities. Fixed or plug-in Main Incoming MCCB for MCC. Withdrawable Air Power Circuit breakers, type Magnum IEC, Narrow and Standard Designs Soft-starters and AFD fixed units. Three-defined positions for draw-out units: connect, test and removed. Double-sectionalizing of power circuits stabs in the withdrawable units. Double-withdrawing (power & control circuits) in the withdrawable units. Automatic control plug with 25 available connection points for buckets / wrappers units of MCC. Automatic control plug for withdrawable Magnum circuit-breakers Optional MCC bucket racking mechanism with respective front door closed. Lifting angles for each transport unit Cables connection: top or bottom. Cable compartment with 250mm of width for MCC sections.
n n n n
EATON CORPORATION
Famlia Gemini
EATON CORPORATION
Famlia Gemini
Entrada/ interligao Magnum 4000 6300A Incoming / Tie Magnum 4000 - 6300A
Alimentadores Disjuntor de Potncia Magnum at 1600A (Narrow) Feeders Power CB Magnum up to 1600A (ND)
EATON CORPORATION
Famlia Gemini
EATON CORPORATION
Famlia Gemini
TTA (Type-Tested low-voltage switchgear and controlgear Assembly CMC com ensaios de tipo totalmente efetuados): Um painel de BT que est em conformidade com um tipo ou sistema estabelecido sem apresentar desvios que possam influenciar o seu desempenho quando comparado com o prottipo tpico ensaiado e aprovado conforme a NBR IEC 60439-1.
TTA (Type-tested low-voltage switchgear and controlgear assembly): A low-voltage switchgear and controlgear ASSEMBLY conforming to an established type or system without deviations likely to significantly influence the performance, from the typical ASSEMBLY verified to be in accordance with IEC 60439-1.
PTTA (Partially Type-Tested low-voltage switchgear and controlgear Assembly CMC com ensaios de tipo parcialmente efetuados): Um painel de BT que apresenta tanto configuraes ensaiadas quanto outras no ensaiadas, mas cujos desvios foram derivados, por exemplo, por clculo, a partir de prottipos ensaiados e que satisfizeram os requisitos de norma (NBR IEC 60439-1).
PTTA (Partially Type-Tested low-voltage switchgear and controlgear): A low-voltage switchgear and controlgear ASSEMBLY containing both type-tested and non-type-tested arrangements, provided that the latter are derived (e.g. by calculation) from type-tested arrangements which have complied with the relevant tests (see table 7 from IEC 60439-1).
Um conjunto TTA deve atender os requisitos dos seguintes ensaios: Limites de elevao de temperatura. Verificao das propriedades dieltricas atravs de ensaio. Corrente suportvel de curto-circuito. Verificao da eficcia da conexo entre as partes condutoras expostas do CMC e o circuito de proteo. Isto deve ser feito atravs de inspeo ou medio de resistncia. Alm disso, a NBR solicita a verificao da corrente suportvel de curtocircuito do circuito de proteo. Verificao das distncias de isolao e escoamentos. Verificao do funcionamento (operao) mecnico. Verificao do grau de proteo (IP ver IEC 60529).
A TTA assembly should comply with the following tests: Temperature-rise limits. Dielectric properties. Short-circuit withstand strength. Effectiveness of the prospective circuits. Effective connection between the exposed conductive parts of the ASSEMBLY and the protective circuit. Short-circuit withstand strength of the protective circuit Clearances and creepage distances. Mechanical operation. Degree of protection (IP see IEC 60529).
Um conjunto PTTA pode diferir de um TTA no atendimento dos seguintes requisitos: Verificao dos limites de elevao de temperatura por teste ou extrapolao a partir de resultados de um conjunto ensaiado. Verificao da isolao atravs de medio da resistncia de isolamento com um megmetro de no mnimo 500V. Verificao da suportabilidade aos esforos da corrente de curto-circuito atravs de ensaio ou extrapolao (clculos) a partir de arranjos com configuraes similares ensaiadas e aprovadas. Verificao da eficcia da conexo entre as partes condutoras expostas do CMC o circuito de proteo atravs de inspeo ou medio de resistncia.
A PTTA assembly could differ from a TTA in the following requirements: Verification of temperature-rise limits by test or extrapolation. Verification of dielectric properties by test according to 8.2.2 or 8.3.2, or verification of insulation resistance according to 8.3.4 (see IEC 60439-1). Verification of short-circuit withstand strength by test or by extrapolation from similar type-tested arrangements. Verification of the effective connection between the exposed conductive parts of the ASSEMBLY and the protective circuit by inspection or by resistance measurement.
Disjuntor de potncia Magnum na posio extrado. Magnum Power-breaker in the withdrawn position.
Final da Insero do Disjuntor de potncia Magnum Ending of Magnum Power-breaker rack-in process.
Tipo 3b
Type 3b
Busbar
Tipo 4b
Type 4b
Busbar
Barramento
Unidade Funcional
Functional Unit
Barramento
Unidade Funcional
Functional Unit
Barramento
Unidade Funcional
Functional Unit
Unidade Funcional
Functional Unit
Unidade Funcional
Functional Unit
Unidade Funcional
Functional Unit
Terminais
Terminals
Terminais
Terminals
Terminais
Terminals
Terminais
Terminals
Terminais
Terminals
Terminais
Terminals
10
EATON CORPORATION
Famlia Gemini
EATON CORPORATION
Famlia Gemini
11
Tabela 1: Arranjos disponveis para Sadas com Magnum - ND (600mm) Table 1: Available Arrangements for Outgoing Feeders With Magnum - ND (600mm).
2140
Aux 800A(F) 400A(S) 800A(F) 630A(S) 1000A(F) 1000A(S)
2140
Aux 800A(F) 400A(S) 800A(F) 400A(S) 1000A(F) 1000A(S)
2140
Aux 800A(F) 400A(S) 800A(F) 800A(S) 800A(F) 800A(S)
2140
Aux 1000A(F) 1000A(S) Aux 1000A(F) 1000A(S)
2140
Aux 800A(F) 800A(S) Aux 1600A(F) 1250A(S)
2140
Aux 800A(F) 400A(S) Aux 1600A(F) 1600A(S)
1960
Aux 800A(F) 400A(S) 800A(F) 400A(S) 1000A(F) 1000A(S)
Comp. C
Comp. D
1960
Aux 800A(F) 800A(S) Aux 1000A(F) 1000A(S)
1660
Aux 800A(F) 800A(S) Aux 800A(F) 800A(S)
1660
Aux 800A(F) 400A(S) Aux 800A(F) 800A(S)
1660
Aux Aux 1600A(F) 1600A(S) Aux
1250
Aux Aux 1600A(F) 1250A(S) Aux
1250
Aux Aux 1000A(F) 1000A(S) Aux
1250
Aux
Aux 800A(F) 800A(S) Aux
Gemini (CCM com entradas e interligao por Disjuntor de Potncia Magnum) Gemini (LV MCC with Magnum Power breaker as incoming and tie breakers)
Comp. C
Comp. D
1250
Aux 800A(F) 600A(S) Aux 800A(F) 630A(S)
1250
Aux 800A(F) 800A(S) 800A(F) 400A(S) 800A(F) 400A(S)
1250
Aux 800A(F) 300A(S) 800A(F) 300A(S) 800A(F) 630A(S)
1250
Aux
Comp. C
Comp. D
Notas - Notes
F - Frame (Corrente Mxima do Disjuntor) Magnum ND - Narrow Design - Magnum MWN SD - Standart Design - Magnum MWI S - Sensores de Corrente - Current Sensors
12 EATON CORPORATION Famlia Gemini EATON CORPORATION Famlia Gemini 13
Tabela 2: Arranjos disponveis para Entradas com Magnum IEC - SD (750 / 1100mm) Table 2: Available Arrangements for Incomings with Magnum IEC - SD (750 / 1100mm)
Tabela 3: Arranjos disponveis para Interligao com Magnum IEC - SD (900 / 1100mm) Table 3: Available Arrangements for Ties with Magnum IEC - SD (900 / 1100mm)
800
Aux Metering & Control 1250A(F) 800A(S) VT/ CPT or Space
1000
Aux Metering & Control 1250A(F) 1000A(S) VT/ CPT or Space
1250
Aux
1600
Aux Metering & Control 2000A(F) 1600A(S) VT/ CPT or Space
2000
Aux Metering & Control 2500A(F) 2000A(S) VT/ CPT or Space
2500
Aux Metering & Control 3200A(F) 2500A(S) VT/ CPT or Space
800
Metering & Control VT/ CPT or Space 1250A(F) 800A(S) VT/ CPT or Space
1000
Metering & Control VT/ CPT or Space 1250A(F) 1000A(S) VT/ CPT or Space
1250
Metering & Control VT/ CPT or Space 1600A(F) 1250A(S) VT/ CPT or Space
1600
Metering & Control VT/ CPT or Space 2000A(F) 1600A(S) VT/ CPT or Space
2000
Metering & Control VT/ CPT or Space 2500A(F) 2000A(S) VT/ CPT or Space
2500
Metering & Control VT/ CPT or Space 3200A(F) 2500A(S) VT/ CPT or Space
Comp. C
Comp. D
Comp. D
3200
Aux Metering & Control 4000A(F) 3200A(S) VT/ CPT or Space
4000
Aux Metering & Control 5000A(F) 4000A(S) VT/ CPT or Space
5000
Aux
2000
Aux Metering & Control 4000A(F) 2000A(S) VT/ CPT or Space
2500
Aux Metering & Control 5000A(F) 2500A(S) VT/ CPT or Space
3200
Aux Metering & Control 5000A(F) 3200A(S) VT/ CPT or Space
3200
Metering & Control VT/ CPT or Space 4000A(F) 3200A(S) VT/ CPT or Space
4000
Metering & Control VT/ CPT or Space 5000A(F) 4000A(S) VT/ CPT or Space
5000
Metering & Control VT/ CPT or Space 6300A(F) 5000A(S) VT/ CPT or Space
2000
Metering & Control VT/ CPT or Space 4000A(F) 2000A(S) VT/ CPT or Space
2500
Metering & Control VT/ CPT or Space 5000A(F) 2500A(S) VT/ CPT or Space
3200
Metering & Control VT/ CPT or Space 5000A(F) 3200A(S) VT/ CPT or Space
Comp. C
Comp. D
Comp. D
800
Aux Metering & Control 1600A(F) 800A(S) VT/ CPT or Space
1000
Aux Metering & Control 2000A(F) 1000A(S) VT/ CPT or Space
1250
Aux
1600
Aux Metering & Control 3200A(F) 1600A(S) VT/ CPT or Space
800
Metering & Control VT/ CPT or Space 1600A(F) 800A(S) VT/ CPT or Space
1000
Metering & Control VT/ CPT or Space 2000A(F) 1000A(S) VT/ CPT or Space
1250
Metering & Control VT/ CPT or Space 2500A(F) 1250A(S) VT/ CPT or Space
1600
Metering & Control VT/ CPT or Space 3200A(F) 1600A(S) VT/ CPT or Space
Comp. C
Comp. D
Comp. D
Notas - Notes
F - Frame (Corrente Mxima do Disjuntor) Magnum ND - Narrow Design - Magnum MWN SD - Standart Design - Magnum MWI S - Sensores de Corrente - Current Sensors
14 EATON CORPORATION Famlia Gemini
Notas - Notes
F - Frame (Corrente Mxima do Disjuntor) Magnum ND - Narrow Design - Magnum MWN SD - Standart Design - Magnum MWI S - Sensores de Corrente - Current Sensors
EATON CORPORATION Famlia Gemini 15
Tabela 4: Partidas Diretas No Reversveis (FVNR / DOL) / Alimentador em unidades extraveis para cargas rotricas (motores) em 480V rms - IEC AC-3 Table 4: Full Voltage Non-reversing (FVNR) / Direct-on-line (DOL) Starters in withdrawable units for IEC AC-3 Motor Loads at 480V rms
kW
HP
HP
1,6 4,2 6,5 9,7 13,0 18,0 24,0 30,0 36,0 47,0 58,0 69,0 85,0 112,0 138,0 138,0 167,0 191,0 223,0
2,5 2,5 2,5 2,5 2,5 4,0 4,0 6,0 10,0 16,0 16,0 25,0 35,0 50,0 70,0 70,0 95,0 95,0 120,0
HMCPE003A0C HMCPE007C0C HMCPE015E0C HMCPE015E0C HMCPE030H1C HMCPE030H1C HMCPE030H1C HMCPE050K2C HMCPE050K2C HMCPE070M2C HMCPE100R3C HMCPE100T3C HMCPE100T3C HMCPJ250J5L HMCPJ250K5L HMCPJ250K5L HMCPJ250W5L HMCPJ250W5L HMCPL600N6G
GE GE GE GE GE GE GE GE GE GE GE GE GE GJ GJ GJ GJ GJ GL
DILM7-01 DILM9-01 DILM12-01 DILM15-01 DILM17-01 DILM25-01 DILM25-01 DILM40 DILM40 DILM50 DILM65 DILM80 DILM95 DILM115 DILM185/22 DILM185/22 DILM225/22 DILM250/22 DILM250/22
B B B B C C C D D D D F F G G L L L L
ZB12-2,4 ZB12-6 ZB12-10 ZB12-12 ZB32-16 ZB32-24 ZB32-32 ZB65-40 ZB65-40 ZB65-57 ZB65-65 ZB150-70 ZB150-100 ZB150-125 ZB150-150 Z5-160/FF250 Z5-220/FF250 Z5-220/FF250 Z5-250/FF250
B B B B C C C D D D D F F G G L L L L
1 1 1 1 1 1 1 1 1 1 1 2 2 3 3 3 3 4 4
A06C3A A06C3A A09D3A A06C3A B18G3A B18G3A B25J3A B32J3A C40L3A C50L3A D65N3A D85N3A D1ON3A E12R3A E12R3A E12R3A F25S3A F25S3A F25T3A
A A A A B B B B C C D D D E E E F F F
1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 3 3 4
Demarrador partida direta IEC (FVNR) - motor 5HP Demarrador partida direta IEC (FVNR) - motor 7,5HP
Direct-on-line starter (FVNR) - motor 7,5HP Direct-on-line starter (FVNR) - motor 10HP Direct-on-line starter (FVNR) - motor 15HP
Demarrador partida direta IEC (FVNR) - motor 10HP Demarrador partida direta IEC (FVNR) - motor 15HP Demarrador partida direta IEC (FVNR) - motor 20HP
Direct-on-line starter IEC (FVNR) - motor 20HP
Direct-on-line (FVNR)
Demarrador partida direta IEC (FVNR) - motor 30HP Demarrador partida direta IEC (FVNR) - motor 40HP Demarrador partida direta IEC (FVNR) - motor 50HP Demarrador partida direta IEC (FVNR) - motor 60HP Demarrador partida direta IEC (FVNR) - motor 75HP Demarrador partida direta IEC (FVNR) - motor 100HP
Direct-on-line starter (FVNR) - motor 100HP Direct-on-line starter (FVNR) - motor 125HP
Demarrador partida direta IEC (FVNR) - motor 175HP Demarrador partida direta IEC (FVNR) - motor 200HP
16
EATON CORPORATION
Famlia Gemini
EATON CORPORATION
Famlia Gemini
Demarrador - Frame
Tipo de Demarrador
Thermal OL Relay - Z
Disjuntor - Frame
Contator - Frame
Rel Trmico - Z
Contactor - Frame
Contator - DIL
OL Relay - Frame
Contactor - DIL
Starter Frame
Type of Starter
MCCB - Frame
kW AC-3
Narrow Frame (MWN) 4 800 1000 1250 5 800 1000 1250 1600 2000 6 800 1000 1250 1600 2000
Standard Frame (MWI) 6 800 1000 1250 1600 ~ ~ ~ 6 ~ ~ ~ ~ 2000 2500 3200 65/65 65/50 30 50 425,7 371,9 410,2 537,2 524,3 474,2 431,8 558,8 58-68 72-86 70-86 88-112 53-56 55-68 8 800 1000 1250 1600 2000 2500 3200 85/85 85/65 30 50 425,7 371,9 410,2 537,2 524,3 474,2 431,8 558,8 58-68 72-86 70-86 88-112 53-56 55-68 C 800 1000 1250 1600 2000 2500 3200 100/85 4 85/65 30 50 425,7 371,9 410,2 537,2 524,3 474,2 431,8 558,8 58-68 72-86 70-86 88-112 53-56 55-68
Duplo Frame (MWI) 64 4000 84 4000 5000 6300 5 4000 5000 6300
Narrow Frame (MWN) 4 800 1000 1250 5 800 1000 1250 1600 2000 6 800 1000 1250 1600 2000
Standard Frame (MWI) 6 800 1000 1250 1600 ~ ~ ~ 6 ~ ~ ~ ~ 2000 2500 3200 65/65 65/50 30 50 425,7 371,9 410,2 537,2 524,3 474,2 431,8 558,8 58-68 72-86 70-86 88-112 53-56 55-68 8 800 1000 1250 1600 2000 2500 3200 85/85 85/65 30 50 425,7 371,9 410,2 537,2 524,3 474,2 431,8 558,8 58-68 72-86 70-86 88-112 53-56 55-68 C 800 1000 1250 1600 2000 2500 3200 100/85 4 85/65 30 50 425,7 371,9 410,2 537,2 524,3 474,2 431,8 558,8 58-68 72-86 70-86 88-112 53-56 55-68
Duplo Frame (MWI) 64 4000 84 4000 5000 6300 5 4000 5000 6300
~ ~
~ ~
Capacidade de interrupo em 690 VAC Icu/Ics (kA rms) Corrente de Curta Durao Icw 1seg/3seg (kA rms) Tempo Mximo de Abertura (mseg) Tempo Mximo de Fechamento (mseg) Dimenses (mm)
5
40/40 40/~ 30 50 425,7 371,9 317,7 413 524,3 474,2 336 431,3 43 54 48 62 28 32
50/50 50/~ 3 30 50 425,7 371,9 317,7 413 524,3 474,2 336 431,3 43 54 48 62 28 32
65/65 65/40 30 50 425,7 371,9 317,7 413 524,3 474,2 336 431,3 43 54 48 62 28 32
65/65 65/~ 30 50 425,7 371,9 410,2 537,2 524,3 474,2 431,8 558,8 58-68 72-86 70-86 88-112 53-56 55-68
65/65 65/~ 40 70 425,7 371,9 886,5 1120 524,3 474,2 909 1036 107,5 144,7 138,8 166 90,3 113,4
85/85 85/~ 40 70 425,7 371,9 886,5 1120 524,3 474,2 909 1036 125,2 163,3 157,4 200 96,2 120,7
100/100 100/~ 40 70 425,7 371,9 886,5 1120 524,3 474,2 909 1036
Interrupt ratings at 690 Vac Icu/Ics (kArms) Withstand rating Icw 1 sec/3 sec (kArms) Maximum break time (msec) Maximum closing time (msec) Circuit breaker dimensions (mm)
5
40/40 40/~ 30 50
50/50 50/~ 3 30 50 425,7 371,9 317,7 413 524,3 474,2 336 431,3 43 54 48 62 28 32
65/65 65/40 30 50 425,7 371,9 317,7 413 524,3 474,2 336 431,3 43 54 48 62 28 32
65/65 65/~ 30 50 425,7 371,9 410,2 537,2 524,3 474,2 431,8 558,8 58-68 72-86 70-86 88-112 53-56 55-68
65/65 65/~ 40 70 425,7 371,9 886,5 1120 524,3 474,2 909 1036 107,5 144,7 138,8 166 90,3 113,4
85/85 85/~ 40 70 425,7 371,9 886,5 1120 524,3 474,2 909 1036 125,2 163,3 157,4 200 96,2 120,7
100/100 100/~ 40 70 425,7 371,9 886,5 1120 524,3 474,2 909 1036 125,2 163,3 157,4 200 96,2 120,7
Altura Fixo Profundidade Largura (3-plos) Largura (4-plos) Altura Extrao Profundidade Largura (3-plos) Largura (4-plos) Peso do disjuntor de circuito (kg) 5 Fixo Extravel Cela (3-plos) (4-plos) (3-plos) (4-plos) (3-plos) (4-plos)
Height Fixed Depth Width (3-pole) Width (4-pole) Height Drawout Depth Width (3-pole) Width (4-pole) Circuit breaker weight (kg)
5
Caractersticas para uso como interruptor Capacidade de interrupo em 690 Vac Icu/Ics (kA rms) Corrente de Curta Durao Icw 1seg/3seg (kA rms) Corrente Nominal (ampres) Corrente de fechamento e engate kA (pico) 6 Corrente Nominal Mxima (ampres) Corrente de fechamento e engate kA (pico) 6
1
7 7
Maximum interrupt ratings at 690 Vac Icu/Ics (kArms) Withstand ratings Icw 1 sec/3 sec (kArms) Continuous current range (A) Close and latch current (kA peak)
6
7 7
~ ~ ~ ~
~ ~ ~ ~
Maximum continuous current range (A) Close and latch current (kA peak)
1
6
Disjuntores equipados com unidades de disparo eletrnicas integradas (Digitrip) possuem sistema de proteo de tentativa de fechamento em falta pr-ajustado para atuao instantnea com valores de corrente de pico superiores a 25x In. 2 Para esquema IT, os disjuntores Magnum possuem caractersticas relacionadas tenso de 440Vac conforme a NBR IEC 60947-2 Anexo H. Consulte a Eaton para aplicaes de esquema IT para tenso de 690Vac. 3 A capacidade Icw 1seg/ 3seg de 50/30 kA para o disjuntor MWN de 2000A/50 kA
Disjuntores Standard Frame (MWI) de 100 kA so ajustados com alto valor instantneo de disparo para proteo acima de 85 kA. Valor de Icu de 100 kA e Ics de 85 kA em 690Vac. 5 O peso e dimenses mostrados consideram terminais horizontais. 6 A corrente de fechamento e engate aplicvel somente para o uso em disjuntores utilizados como chaves no automticas. Chaves no automticas devem ser aplicadas com dispositivo de sobrecorrente externo apropriado com proteo instantnea de disparo para proteger correntes superiores as correntes de fechamento e engate correspondentes ao disjuntor. 7 A capacidade de interrupo mxima para o Standard Frame (MWI) utilizado como chave no-automtico de 85 KA.
Circuit breakers equipped with integral trip units have a making current release set to trip instantaneously at 25 x In peak current to prevent closing on a fault current exceeding that magnitude. 2 Magnum ACBs carry an IT rating at 440 Vac per IEC 60947-2 Annex H. Contact Eaton for 690 Vac IT applications. 3 The Icw 1 sec/3 sec rating is 50/30 kA for 2000 A MWN 50 kA breaker. 4 Standard frame circuit breakers rated 100 kA are equipped with a high instantaneous trip set to protect above 85 kArms. Icu is 100 kA and Ics is 85 kA at 440 Vac. Icu and Ics are 85 kA at 690 Vac.
The approximate weights and dimensions shown are based on horizontal terminals. 6 Close and latch ratings are applicable only to non-automatic switches. Non-automatic switches should be applied with a suitable external overcurrent device with instantaneous trip to protect above the published close and latch rating. 7 The maximum available instantaneous interrupting rating for the standard frame non-automatic switch is 85 kA.
18
EATON CORPORATION
Famlia Gemini
EATON CORPORATION
Famlia Gemini
19
Na indstria eltrica, a Eaton lder mundial em servios e produtos para controles eltricos, distribuio de energia, UPS, bem como produtos e servios para automao industrial. Atravs de sua avanada engenharia de produto, com mtodos de fabricao de padro global, alm de servios e suporte tcnico, a Diviso Eltrica de Negcios da Eaton desenvolve solues com foco nos clientes, atravs de marcas de renome como: Cutler-Hammer, Powerware, Durant, Heinemann, Holec e MEM, que atendem globalmente s diferentes necessidades dos mercados industriais, concessionrias de energia, residencial, comercial, TI e OEM. A Eaton Corporation um fabricante industrial diversicado com vendas de US$ 15,4 bilhes em 2008. A Eaton
lder mundial em sistemas eltricos e componentes para controle, distribuio e qualidade de energia. Tambm lder em servios e sistemas hidrulicos para equipamentos industriais, mveis e areos; sistemas de direo inteligente para economia de combustvel e segurana em caminhes; sistemas de controle de ar para motores automotivos, bem como solues inteligentes para economia de combustvel e aumento da performance e segurana em motores e outros sistemas. A Eaton conta com 75 mil prossionais e comercializa seus produtos para clientes em mais de 150 pases. Para informaes adicionais sobre a linha completa de produtos Eaton, visite o site www.eaton.com.br
Filiais de Vendas: Tel.: 11 2159-7150 Fax: 11 2159-7156 Tel: 19 2117-0032 2117-0033 2117-0034 Tel.: 31 2112-7070 Fax: 31 2112-7085
Grande So Paulo
Interior de So Paulo e Centro-Oeste Minas Gerais e Norte Rio de Janeiro, Esprito Santo e Nordeste Paran
Tel.: 21 2106-3299 Fax: 21 3884-8704 Tel.: 41 2107-9850 Fax: 41 2107-9851 Tel.: 47 3461-3179 Fax: 47 3461-3101 Tel.: 51 2117-7000 Fax: 51 2117-7004
Santa Catarina
2011 Eaton Corporation Todos os direitos reservados Impresso no Brasil Pub. N BR verso 01 - 03/11 Maro/2011
www.eaton.com.br