Revision History
Revision -001 -002 -003 Revision History First release of the Intel Desktop Board DP55SB Product Guide Second release of the Intel Desktop Board DP55SB Product Guide Third release of the Intel Desktop Board DP55SB Product Guide Date July 2009 December 2009 April 2010
If an FCC declaration of conformity marking is present on the board, the following statement applies:
Disclaimer
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTELS TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER, AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice. Intel Desktop Board DP55SB may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request. Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order. Copies of documents which have an ordering number and are referenced in this document, or other Intel literature, may be obtained from Intel Corporation by going to the World Wide Web site at: http://www.intel.com/ or by calling 1-800-548-4725. Intel is a trademark of Intel Corporation in the United States and other countries. * Other names and brands may be claimed as the property of others. Copyright 2009, 2010, Intel Corporation. All rights reserved.
Preface
This Product Guide gives information about board layout, component installation, BIOS update, and regulatory requirements for Intel Desktop Board DP55SB.
Intended Audience
The Product Guide is intended for technically qualified personnel. It is not intended for general audiences.
Document Organization
The chapters in this Product Guide are arranged as follows: 1 2 3 4 A B Desktop Board Features: a summary of product features Installing and Replacing Desktop Board Components: instructions on how to install the Desktop Board and other hardware components Updating the BIOS: instructions on how to update the BIOS Configuring for RAID Using Intel Matrix Storage Technology: information about configuring your system for RAID Error Messages and Indicators: information about BIOS error messages and beep codes Regulatory Compliance: describes the boards adherence to safety standards and EMC regulations and its product certifications
Conventions
The following conventions are used in this manual:
CAUTION
Cautions warn the user about how to prevent damage to hardware or loss of data.
NOTE
Notes call attention to important information.
iii
Terminology
The table below gives descriptions of some common terms used in the product guide.
Term GB GHz KB MB Mb MHz Description Gigabyte (1,073,741,824 bytes) Gigahertz (one billion hertz) Kilobyte (1024 bytes) Megabyte (1,048,576 bytes) Megabit (1,048,576 bits) Megahertz (one million hertz)
iv
Contents
1 Desktop Board Features
Supported Operating Systems..............................................................................11 Desktop Board Components.................................................................................12 Processor..........................................................................................................14 Main Memory.....................................................................................................15 Intel P55 Express Chipset ..................................................................................16 Audio Subsystem ...............................................................................................16 LAN Subsystem .................................................................................................16 Bluetooth* Technology Support............................................................................17 USB 2.0 Support ................................................................................................18 Serial ATA Support .............................................................................................18 Legacy I/O ........................................................................................................19 Expandability.....................................................................................................19 BIOS ................................................................................................................20 Serial ATA Auto Configuration.......................................................................20 PCI Express* Auto Configuration...................................................................20 Security Passwords .....................................................................................20 Hardware Management .......................................................................................21 Hardware Monitoring and Fan Speed Control ..................................................21 Intel Precision Cooling Technology .......................................................21 Chassis Intrusion........................................................................................21 Power Management ............................................................................................22 Software Support .......................................................................................22 ACPI..................................................................................................22 Hardware Support ......................................................................................22 Power Connectors ...............................................................................22 Fan Headers .......................................................................................23 LAN Wake Capabilities..........................................................................23 Instantly Available PC Technology..........................................................23 +5 V Standby Power Indicator...............................................................24 Wake from USB ..................................................................................25 PME# Signal Wake-up Support..............................................................25 WAKE# Signal Wake-up Support ...........................................................25 Wake from Consumer IR ......................................................................25 ENERGY STAR*, e-Standby, and EuP Compliance ............................................25 Onboard Power Button........................................................................................26 Processor and Voltage Regulator LEDs ..................................................................27 Back to BIOS Button...........................................................................................28 Speaker............................................................................................................29 Battery .............................................................................................................29 Real-Time Clock.................................................................................................29
Installing the I/O Shield ......................................................................................33 Installing and Removing the Desktop Board ...........................................................34 Installing and Removing a Processor .....................................................................35 Installing a Processor ..................................................................................35 Installing the Processor Fan Heat Sink ...........................................................40 Connecting the Processor Fan Heat Sink Cable................................................40 Removing the Processor ..............................................................................40 Installing and Removing System Memory ..............................................................41 Guidelines for Dual Channel Memory Configuration ..........................................41 Two or Four DIMMs .............................................................................41 Three DIMMs ......................................................................................42 Installing DIMMs ........................................................................................43 Removing DIMMs........................................................................................45 Installing and Removing PCI Express x16 Graphics Cards.........................................45 Installing a PCI Express x16 Graphics Card ....................................................45 Removing a PCI Express x16 Graphics Card....................................................46 Installing Linked PCI Express Graphics Cards ..................................................47 Connecting the Serial ATA (SATA) Cables ..............................................................49 Connecting to the Internal Headers ......................................................................50 Front Panel Intel HD Audio Header ................................................................51 Consumer IR (CIR) Headers .........................................................................51 Front Panel Header .....................................................................................52 Alternate Front Panel Power LED Header ........................................................52 USB 2.0 Headers ........................................................................................53 IEEE 1394a Header .....................................................................................53 Chassis Intrusion Header .............................................................................54 S/PDIF Header ...........................................................................................54 Connecting to the Audio System...........................................................................55 Connecting Chassis Fan and Power Supply Cables...................................................56 Connecting Chassis Fan Cables .....................................................................56 Connecting Power Supply Cables ..................................................................57 Connecting the Bluetooth Antenna........................................................................58 Setting the BIOS Configuration Jumper .................................................................59 Clearing Passwords ............................................................................................60 Replacing the Battery .........................................................................................61
vi
Contents
B Regulatory Compliance
Safety Standards ...............................................................................................79 Place Battery Marking .................................................................................79 European Union Declaration of Conformity Statement..............................................80 Product Ecology Statements ................................................................................81 Recycling Considerations .............................................................................81 Lead-free 2LI/Pb-free 2LI Board ...................................................................84 Restriction of Hazardous Substances (RoHS) ..................................................85 EU RoHS ............................................................................................85 China RoHS ........................................................................................86 EMC Regulations ................................................................................................88 Ensure Electromagnetic Compatibility (EMC) Compliance ..................................89 Product Certifications..........................................................................................90 Board-Level Certification Markings ................................................................90 Chassis and Component Certifications............................................................91
Figures
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. Intel Desktop Board DP55SB Components ........................................................12 LAN Connector LEDs .....................................................................................17 SATA Drive Activity LED ................................................................................18 Location of the Standby Power Indicator ..........................................................24 Onboard Power Button ..................................................................................26 Location of the Processor and Voltage Regulator LEDs........................................27 Location of the Back to BIOS Button................................................................28 Installing the I/O Shield ................................................................................33 Intel Desktop Board DP55SB Mounting Screw Hole Locations ..............................34 Unlatch the Socket Lever ...............................................................................35 Lift the Load Plate.........................................................................................36 Remove the Socket Cover..............................................................................37 Remove the Processor from the Protective Cover ..............................................38 Install the Processor .....................................................................................38 Lower the Load Plate.....................................................................................39 Secure the Load Plate in Place ........................................................................39 Connecting the Processor Fan Heat Sink Power Cable to the Processor Fan Header..................................................................................................40 Example Dual Channel Memory Configuration with Two DIMMs ...........................41 Example Dual Channel Memory Configuration with Four DIMMs ...........................42 Example Dual Channel Memory Configuration with Three DIMMs .........................42 Use DDR3 DIMMs .........................................................................................43 Installing a DIMM .........................................................................................44 Installing a PCI Express x16 Graphics Card ......................................................46 Removing a PCI Express x16 Graphics Card......................................................47 Installing Linked PCI Express Graphics Cards....................................................48 Connecting the Serial ATA Cables....................................................................49 Internal Headers ..........................................................................................50
vii
Back Panel Audio Connectors .........................................................................55 Location of the Chassis Fan Headers................................................................56 Connecting Power Supply Cables ....................................................................57 Connecting the Bluetooth Antenna ..................................................................58 Location of the BIOS Configuration Jumper Block ..............................................59 Removing the Battery ...................................................................................66 POST Code LED Display .................................................................................75 Intel Desktop Board DP55SB China RoHS Material Self Declaration Table ..............87
Tables
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. Feature Summary.......................................................................................... 9 Intel Desktop Board DP55SB Components ........................................................13 LAN Connector LEDs .....................................................................................17 Front Panel Intel HD Audio Header Signal Names ..............................................51 Front Panel CIR Receiver (Input) Header Signal Names ......................................51 Back Panel CIR Header Emitter (Output) Header Signal Names ...........................52 Front Panel Header Signal Names ...................................................................52 Alternate Front Panel Power LED Header Signal Names ......................................52 USB 2.0 Header Signal Names........................................................................53 IEEE 1394a Header Signal Names ...................................................................53 Chassis Intrusion Header Signal Names ...........................................................54 S/PDIF Header Signal Names .........................................................................54 Jumper Settings for the BIOS Setup Program Modes..........................................60 BIOS Beep Codes .........................................................................................73 Front-panel Power LED Blink Codes .................................................................73 BIOS Error Messages ....................................................................................74 Port 80h POST Codes ....................................................................................76 Safety Standards..........................................................................................79 Lead-Free Second Level Interconnect Marks .....................................................85 China RoHS Environmentally Friendly Use Period Mark .......................................86 EMC Regulations...........................................................................................88 Product Certification Markings ........................................................................90
viii
HD Audio front panel header Onboard 4-pin S/PDIF out connector Back panel S/PDIF out and in optical connectors Expansion Capabilities Legacy I/O Support Peripheral Interfaces One PCI Express 2.0 x16 port One PCI Express 2.0 x8 port Two PCI Express 2.0 x1 ports Legacy I/O Controller that provides Consumer Infrared (CIR) support Up to 13 USB 2.0 ports: Eight ports routed to eight back panel USB connectors Four ports routed to two onboard USB headers One port routed to an onboard vertical USB connector One port routed to the back panel IEEE 1394a connector One port routed to an IEEE 1394a header
Six Serial ATA (SATA) channels (3.0 Gb/s) via the PCH Two external SATA (eSATA) channels via a discrete controller RAID Intel Matrix Storage Technology for Serial ATA continued
10
11
12
13
Online Support For more information on Intel Desktop Board DP55SB consult the following online resources:
Intel Desktop Board DP55SB Desktop Board Support Available configurations for Intel Desktop Board DP55SB Supported processors Chipset information BIOS and driver updates Integration information http://www.intel.com/products/motherboard/DP55SB/ index.htm http://support.intel.com/support/motherboards/deskt op/DP55SB http://www.intel.com/products/motherboard/DP55SB/ index.htm http://processormatch.intel.com http://www.intel.com/products/desktop/chipsets/inde x.htm http://downloadcenter.intel.com/ http://www.intel.com/support/go/buildit
Processor
CAUTION
Failure to use an appropriate power supply and/or not connecting the 12 V (2 x 4 pin) power connector to the Desktop Board may result in damage to the board, or the system may not function properly. Intel Desktop Board DP55SB supports an Intel processor in the LGA1156 package. Processors are not included with the Desktop Board and must be purchased separately. The processor connects to the Desktop Board through the LGA1156 socket. For information on supported processors for Intel Desktop Board DP55SB, go to http://processormatch.intel.com.
14
Main Memory
NOTE
To be fully compliant with all applicable Intel SDRAM memory specifications, the board should be populated with DIMMs that support the Serial Presence Detect (SPD) data structure. If your memory modules do not support SPD, you will see a notification to this effect on the screen at power up. The BIOS will attempt to configure the memory controller for normal operation. The Desktop Board supports the following memory and interface: Four 240-pin Double Data Rate 3 (DDR3) SDRAM Dual Inline Memory Module (DIMM) connectors with gold-plated contacts arranged in two channels 1600+/1333/1066 MHz DDR3 SDRAM Memory Modules
NOTE
DDR3 1600 or higher memory support on this desktop board requires compatible XMP-enabled memory or advanced knowledge of BIOS and manual memory tuning. Individual results may vary. Support for single- and dual-channel memory interleaving Unbuffered, non-registered single- or double-sided DIMMs with a voltage rating of 1.65 V or less
NOTE
Using a DIMM with a voltage rating higher than 1.65 V may damage the processor. Non-ECC DDR3 memory Serial Presence Detect (SPD) memory only Up to 16 GB maximum total system memory
NOTE
32-bit operating systems are limited to a maximum of 4 GB of memory. These operating systems will report less than 4 GB because of the memory used by add-in graphics cards and other system resources.
15
Audio Subsystem
The onboard audio subsystem consists of the following components: Intel P55 PCH Realtek ALC889 codec Back panel audio connectors, including S/PDIF in and out optical ports High Definition Audio front panel header that provides mic in and line out signals for front panel audio connectors An onboard S/PDIF header Dolby* Home Theater certification A signal-to-noise (S/N) ratio of 95 dB Independent multi-streaming 8-channel (7.1) audio (using the back panel audio connectors) and 2-channel audio (using the High Definition Audio front panel header)
LAN Subsystem
The LAN subsystem includes: Intel PCH Intel 82578DM Gigabit (10/100/1000 Mb/s) Ethernet LAN controller RJ-45 LAN connector with integrated status LEDs CSMA/CD protocol engine LAN connect interface between PCH and the LAN controller PCI bus power management
16
Two LEDs are built into the RJ-45 LAN connector located on the back panel (see Figure 2). These LEDs indicate the status of the LAN as shown in Table 3.
17
18
The six onboard SATA channels provided by the PCH support the following Intel Matrix Storage Technology RAID (Redundant Array of Independent Drives) levels: RAID RAID RAID RAID 0 - data striping 1 - data mirroring 0+1 (or RAID 10) - data striping and data mirroring 5 - distributed parity
NOTE
In order to use supported onboard RAID features, you must first enable RAID in the BIOS. Also, during Microsoft Windows XP installation, you must press the F6 key to install the RAID drivers. Refer to your Microsoft Windows XP documentation for more information about installing drivers during installation. Both Microsoft Windows Vista and Microsoft Windows 7 include the necessary RAID drivers for both AHCI and RAID without the need to install separate RAID drivers using the F6 key. The red eSATA connector on the back panel can be used to connect an eSATA drive.
Legacy I/O
Intel Desktop Board DP55SB includes an I/O controller that provides the following legacy I/O features: Consumer Infrared (CIR) support Low pin count (LPC) interface Intelligent power management, including a programmable wake up event interface PCI power management support
Expandability
Intel Desktop Board DP55SB provides the following expansion capability: One PCI Express 2.0 x16 port (x8/x16 electrical) One PCI Express 2.0 x8 port (x8 electrical; x16 compatible) Two PCI Express 2.0 x1 ports
19
BIOS
The BIOS provides the Power-On Self-Test (POST), the BIOS Setup program, and the PCI Express and SATA auto-configuration utilities. The BIOS is stored in the Serial Peripheral Interface (SPI) Flash device. The BIOS can be updated by following the instructions in Chapter 3 starting on page 67.
Security Passwords
The BIOS includes security features that restrict whether the BIOS Setup program can be accessed and who can boot the computer. A supervisor password and a user password can be set for the BIOS Setup and for booting the computer, with the following restrictions: The supervisor password gives unrestricted access to view and change all Setup options. If only the supervisor password is set, pressing <Enter> at the password prompt of Setup gives the user restricted access to Setup. If both the supervisor and user passwords are set, you must enter either the supervisor password or the user password to access Setup. Setup options are then available for viewing and changing depending on whether the supervisor or user password was entered. Setting a user password restricts who can boot the computer. The password prompt is displayed before the computer is booted. If only the supervisor password is set, the computer boots without asking for a password. If both passwords are set, you can enter either password to boot the computer.
Related Links: For instructions on resetting the password, go to Clearing Passwords on page 60.
20
Hardware Management
The hardware management features of Intel Desktop Board DP55SB enable the board to be compatible with the Wired for Management (WfM) specification. The board has several hardware management features including the following: Fan speed monitoring and control Thermal and voltage monitoring Chassis intrusion detection
Chassis Intrusion
The board supports a chassis security feature that detects if the chassis cover has been removed. The security feature uses a mechanical switch on the chassis that can be connected to the chassis intrusion header on the Desktop Board. See Figure 27 for the location of the chassis intrusion header.
21
Power Management
Power management is implemented at several levels, including software support through the Advanced Configuration and Power Interface (ACPI) and the following hardware support: Power connectors Fan headers LAN wake capabilities Instantly Available PC technology (Suspend to RAM) +5 V standby power indicator LED Wake from USB Power Management Event signal (PME#) wakeup support WAKE# signal wake-up support Wake from Consumer IR
Software Support
ACPI
ACPI gives the operating system direct control over the power management and Plug and Play functions of a computer. The use of ACPI with the Desktop Board requires an operating system that provides full ACPI support.
Hardware Support
Power Connectors
ATX12V-compliant power supplies can turn off the computer power through system control. When an ACPI-enabled computer receives the correct command, the power supply removes all non-standby voltages. When resuming from an AC power failure, the computer returns to the power state it was in before power was interrupted (either on or off). The computers response can be set by using the Last Power State feature in the BIOS Setup programs Boot menu. The Desktop Board has three power connectors. See Figure 30 on page 57 for the location of the power connectors.
22
Fan Headers
The function/operation of the fans is as follows: The fans are on when the computer is in the ACPI S0 state. The fans are off when the computer is in the ACPI S3, S4, or S5 state. Each fan header is wired to a tachometer input of the hardware monitoring and control device. All fan headers support closed-loop fan control that can adjust the fan speed or switch the fan on or off as needed. All fan headers have a +12 V DC connection.
The Desktop Board has a 4-pin processor fan header and two 4-pin chassis fan headers.
23
The Desktop Board supports the PCI Bus Power Management Interface Specification. Add-in cards that support this specification can participate in power management and can be used to wake the computer.
Figure 4. Location of the Standby Power Indicator For more information on standby current requirements for the Desktop Board, refer to the Technical Product Specification at http://support.intel.com/support/motherboards/desktop/
24
25
26
27
NOTE
Using the Back to BIOS button does not set the board to the factory BIOS defaults. To restore settings to the factory defaults, use the <F9> key once BIOS setup mode is active.
28
Speaker
A speaker is mounted on the Desktop Board. The speaker provides audible error code (beep code) information during the Power-On Self-Test (POST). Refer to Appendix A for a description of the boards beep codes.
Battery
A battery on the Desktop Board keeps the values in CMOS RAM and the clock current when the computer is turned off. Go to page 61 for instructions on how to replace the battery.
Real-Time Clock
The Desktop Board has a time-of-day clock and 100-year calendar. The battery on the Desktop Board keeps the clock current when the computer is turned off.
29
30
31
Installation Precautions
When you install and test the Intel Desktop Board, observe all warnings and cautions in the installation instructions. To avoid injury, be careful of: Sharp pins on connectors Sharp pins on printed circuit assemblies Rough edges and sharp corners on the chassis Hot components (such as processors, voltage regulators, and heat sinks) Damage to wires that could cause a short circuit
Observe all warnings and cautions that instruct you to refer computer servicing to qualified technical personnel.
32
33
34
Installing a Processor
CAUTION
Before installing or removing a processor, make sure the AC power has been removed by unplugging the power cord from the computer; the standby power LED should not be lit (see Figure 4 on page 24). Failure to do so could damage the processor and the board. To install a processor, follow these instructions: 1. Observe the precautions in "Before You Begin" on page 31. 2. Unlatch the socket lever by pushing the lever down and away from the socket (Figure 10, A and B).
35
3. Rotate the socket lever to lift the load plate away from the socket (Figure 11, A). Make sure that the load plate is in the fully open position (Figure 11, B) while being careful not to damage adjacent components.
36
4. Remove the protective socket cover from the socket by placing your thumb against the front edge of the cover and resting your index finger on the rear grip (Figure 12, A). Lift the front edge of the socket to disengage the cover from the socket and lift the cover up and away from the socket (Figure 12, B). Do not touch the socket contacts.
NOTE
Do not discard the socket cover; save it for possible future use. Always replace the socket cover if you remove the processor from the socket.
37
5. Remove the processor from its protective cover. Hold the processor only at the edges, being careful not to touch the bottom of the processor (see Figure 13).
NOTE
Do not discard the processor cover. Always replace the processor cover if you remove the processor from the socket.
Figure 13. Remove the Processor from the Protective Cover 6. Hold the processor with your thumb and index finger oriented as shown in Figure 14 to align your fingers with the socket finger cutouts. Make sure that the processor Pin 1 indicator (gold triangle) is aligned with the Pin 1 chamfer on the socket (Figure 14, B) and that the notches on the processor align with the posts on the socket (Figure 14, C). Lower the processor straight down without tilting or sliding it in the socket (Figure 14, A).
38
7. Lower the load plate over the processor while leaving the socket lever in the open position(Figure 15).
Figure 15. Lower the Load Plate 8. Lower the socket lever (Figure 16, B) while making sure that the front edge of the load plate slides under the shoulder screw cap as the lever is lowered (Figure 16, A). Latch the socket lever under load plate tab (Figure 16, C, D).
39
Figure 17. Connecting the Processor Fan Heat Sink Power Cable to the Processor Fan Header
40
NOTE
The Intel P55 Express Chipset requires memory to be installed in the Channel A, DIMM 0 slot.
Figure 18. Example Dual Channel Memory Configuration with Two DIMMs If additional memory is to be used, install another matched pair of DIMMs in DIMM 1 (black) in channels A and B (see Figure 19).
41
Figure 19. Example Dual Channel Memory Configuration with Four DIMMs
Three DIMMs
If you want to use three DIMMs in a dual-channel configuration, install a matched pair of DIMMs equal in speed and size in DIMM 0 (blue) and DIMM 1 (black) of channel A. Install a DIMM equal in speed and total size of the DIMMs installed in channel A in either DIMM 0 or DIMM 1 of channel B (see Figure 20).
Figure 20. Example Dual Channel Memory Configuration with Three DIMMs
NOTE
All other memory configurations will result in single channel memory operation.
42
Installing DIMMs
To make sure you have the correct DIMM, place it on the illustration of the DDR3 DIMM in Figure 21. All the notches should match with the DDR3 DIMM.
43
NOTE
For best memory performance, install memory in the blue DIMM sockets first. To install a DIMM, follow these steps: 1. Observe the precautions in "Before You Begin" on page 31. 2. Turn off all peripheral devices connected to the computer. Turn off the computer and disconnect the AC power cord. 3. Remove the computers cover and locate the DIMM sockets (see Figure 22). 4. If a full length PCI Express graphics card is installed in the PCI Express x16 connector, remove the card (see Removing a PCI Express x16 Graphics Card on page 46) to gain access to the DIMM sockets.
Figure 22. Installing a DIMM 5. Make sure the clips at either end of the DIMM socket(s) are pushed outward to the open position. 6. Holding the DIMM by the edges, remove it from its anti-static package. 7. Position the DIMM above the socket. Align the small notch at the bottom edge of the DIMM with the keys in the socket (see inset in Figure 22). 8. Insert the bottom edge of the DIMM into the socket. 9. When the DIMM is inserted, push down on the top edge of the DIMM until the retaining clips snap into place. Make sure the clips are firmly in place.
44
10. Reinstall the PCI Express graphics card (see Installing a PCI Express x16 Graphics Card on page 45) if one was removed in Step 4. 11. Replace the computers cover and reconnect the AC power cord.
Removing DIMMs
To remove a DIMM, follow these steps: 1. 2. 3. 4. 5. Observe the precautions in "Before You Begin" on page 31. Turn off all peripheral devices connected to the computer. Turn off the computer. Remove the AC power cord from the computer. Remove the computers cover. If a full length PCI Express graphics card is installed in the PCI Express x16 connector, remove the card (see Removing a PCI Express x16 Graphics Card on page 46) to gain access to the DIMM sockets. Gently spread the retaining clips at each end of the DIMM socket. The DIMM pops out of the socket. Hold the DIMM by the edges, lift it away from the socket, and store it in an anti-static package. Reinstall the PCI Express graphics card (see Installing a PCI Express x16 Graphics Card on page 45) if one was removed in Step 5 and reconnect any other parts you removed or disconnected to reach the DIMM sockets. Replace the computers cover and reconnect the AC power cord.
6. 7. 8.
9.
CAUTION
When installing a PCI Express card, ensure that the card is fully seated in the PCI Express connector before you power on the system. If the card is not fully seated in the connector, an electrical short may result across the connector pins. Depending on the over-current protection of the power supply, certain Desktop Board components and/or traces may be damaged.
45
Follow these instructions to install a PCI Express x16 graphics card: 1. Observe the precautions in "Before You Begin" on page 31. 2. Place the card in the PCI Express x16 connector (Figure 23, A) and press down on the card until it is completely seated in the connector and the card retention notch on the card snaps into place around the retention mechanism pin on the connector. 3. Secure the cards metal bracket to the chassis back panel with a screw (Figure 23, B). 4. Connect the monitor cable to the graphics card according to the manufacturers instructions.
46
47
Figure 25. Installing Linked PCI Express Graphics Cards For more complete installation and configuration information refer to the documentation supplied by the graphics card manufacturer or visit their website.
48
49
50
NOTE
The Consumer IR option must be enabled in the system BIOS before it can function. Press <F2> at boot to enter the system BIOS, and go to Advanced > Peripheral Configuration > Enhanced Consumer IR, and set this option to Enabled. Table 5 shows the pin assignments and signal names for the front panel CIR receiver (input) header and Table 6 shows the pin assignments and signal names for the back panel CIR emitter (output) header. Table 5. Front Panel CIR Receiver (Input) Header Signal Names
Pin 1 3 5 7 Signal Name Ground No Connection +5 V Standby Key (no pin) Pin 2 4 6 8 Signal Name LED Learn-In Vcc CIR Input
51
Table 6. Back Panel CIR Header Emitter (Output) Header Signal Names
Pin 1 3 5 Signal Name Emitter Out 1 Ground Jack Detect 1 Pin 2 4 6 Signal Name Emitter Out 2 Key (no pin) Jack Detect 2
NOTE
When connecting individual wires from your chassis front panel to the front panel header, be sure to observe the connection polarity. Positive wires are usually solid color and negative wires are usually white or striped.
52
NOTE
Computer systems that have an unshielded cable attached to a USB port might not meet FCC Class B requirements, even if no device or a low-speed USB device is attached to the cable. Use a shielded cable that meets the requirements for a full-speed USB device.
53
S/PDIF Header
Figure 27, I shows the location of the S/PDIF output header. Table 12 shows the pin assignments and signal names for the S/PDIF connector. Table 12. S/PDIF Header Signal Names
Pin 1 2 3 4 Description Ground S/PDIF Out Key (no pin) +5 VDC
54
Item A B C D E F
Description Center Channel and LFE (Subwoofer) Surround Left and Right Side Surround Left and Right/Line In/Retasking Jack Line Out Mic In Side Surround
NOTE
The back panel line out connector is designed to power either headphones or amplified speakers only. Poor audio quality may occur if passive (non-amplified) speakers are connected to this output.
55
56
CAUTION
Failure to use an appropriate power supply and/or not connecting the 12 V (Figure 30, A) power connector to the Desktop Board may result in damage to the board or the system may not function properly. The 2 x 12 pin main power connector (Figure 30, C) is backwards compatible with ATX12V power supplies with 2 x 10 connectors. Use of the SATA-style PCI Express graphics auxiliary power connector (Figure 30, B) is required with ATX12V power supplies when using PCI Express graphics cards that can consume up to 75 W.
57
1. Observe the precautions in "Before You Begin" on page 31. 2. Connect the 12 V processor core voltage power supply cable to the 2 x 4 pin connector (Figure 30, A) . 3. Connect the main power supply cable to the 2 x 12 pin connector (Figure 30, C). 4. If additional power is required for graphics cards, connect the appropriate power supply cable to the SATA-style PCI Express graphics auxiliary power connector (Figure 30, B).
58
Figure 32. Location of the BIOS Configuration Jumper Block The three-pin BIOS jumper block enables board configuration to be done in the BIOS Setup program. Table 13 shows the jumper settings for the BIOS Setup program modes.
59
Table 13. Jumper Settings for the BIOS Setup Program Modes
Jumper Setting Mode Normal (default) (1-2) Description The BIOS uses the current configuration and passwords for booting.
Configure (2-3)
After the Power-On Self-Test (POST) runs, the BIOS displays the Maintenance Menu. Use this menu to clear passwords.
Recovery (None)
Clearing Passwords
This procedure assumes that the board is installed in the computer and the configuration jumper block is set to normal mode. 1. Observe the precautions in "Before You Begin" on page 31. 2. Turn off all peripheral devices connected to the computer. Turn off the computer. Disconnect the computers power cord from the AC power source (wall outlet or power adapter). 3. Remove the computer cover. 4. Find the configuration jumper block (see Figure 32). 5. Place the jumper on pins 2-3 as shown below.
6. Replace the cover, plug in the computer, turn on the computer, and allow it to boot. 7. The computer starts the Setup program. Setup displays the Maintenance menu.
60
8. Use the arrow keys to select Clear Passwords. Press <Enter> and Setup displays a pop-up screen requesting that you confirm clearing the password. Select Yes and press <Enter>. Setup displays the maintenance menu again. 9. Press <F10> to save the current values and exit Setup. 10. Turn off the computer. Disconnect the computers power cord from the AC power source. 11. Remove the computer cover. 12. To restore normal operation, place the jumper on pins 1-2 as shown below.
13. Replace the cover, plug in the computer, and turn on the computer.
CAUTION
Risk of explosion if the battery is replaced with an incorrect type. Batteries should be recycled where possible. Disposal of used batteries must be in accordance with local environmental regulations.
PRCAUTION
Risque d'explosion si la pile usage est remplace par une pile de type incorrect. Les piles usages doivent tre recycles dans la mesure du possible. La mise au rebut des piles usages doit respecter les rglementations locales en vigueur en matire de protection de l'environnement.
FORHOLDSREGEL
Eksplosionsfare, hvis batteriet erstattes med et batteri af en forkert type. Batterier br om muligt genbruges. Bortskaffelse af brugte batterier br foreg i overensstemmelse med gldende miljlovgivning.
61
OBS!
Det kan oppst eksplosjonsfare hvis batteriet skiftes ut med feil type. Brukte batterier br kastes i henhold til gjeldende miljlovgivning.
VIKTIGT!
Risk fr explosion om batteriet erstts med felaktig batterityp. Batterier ska kasseras enligt de lokala miljvrdsbestmmelserna.
VARO
Rjhdysvaara, jos pariston tyyppi on vr. Paristot on kierrtettv, jos se on mahdollista. Kytetyt paristot on hvitettv paikallisten ympristmrysten mukaisesti.
VORSICHT
Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr. Die Batterie darf nur durch denselben oder einen entsprechenden, vom Hersteller empfohlenen Batterietyp ersetzt werden. Entsorgen Sie verbrauchte Batterien den Anweisungen des Herstellers entsprechend.
AVVERTIMENTO
Esiste il pericolo di un esplosione se la pila non viene sostituita in modo corretto. Utilizzare solo pile uguali o di tipo equivalente a quelle consigliate dal produttore. Per disfarsi delle pile usate, seguire le istruzioni del produttore.
PRECAUCIN
Existe peligro de explosin si la pila no se cambia de forma adecuada. Utilice solamente pilas iguales o del mismo tipo que las recomendadas por el fabricante del equipo. Para deshacerse de las pilas usadas, siga igualmente las instrucciones del fabricante.
WAARSCHUWING
Er bestaat ontploffingsgevaar als de batterij wordt vervangen door een onjuist type batterij. Batterijen moeten zoveel mogelijk worden gerecycled. Houd u bij het weggooien van gebruikte batterijen aan de plaatselijke milieuwetgeving.
ATENO
Haver risco de exploso se a bateria for substituda por um tipo de bateria incorreto. As baterias devem ser recicladas nos locais apropriados. A eliminao de baterias usadas deve ser feita de acordo com as regulamentaes ambientais da regio.
ACIAROZNA
, . , , . .
62
UPOZORNN
V ppad vmny baterie za nesprvn druh me dojt k vbuchu. Je-li to mon, baterie by mly bt recyklovny. Baterie je teba zlikvidovat v souladu s mstnmi pedpisy o ivotnm prosted.
. . .
VIGYZAT
Ha a telepet nem a megfelel tpus telepre cserli, az felrobbanhat. A telepeket lehetsg szerint jra kell hasznostani. A hasznlt telepeket a helyi krnyezetvdelmi elrsoknak megfelelen kell kiselejtezni.
AWAS
Risiko letupan wujud jika bateri digantikan dengan jenis yang tidak betul. Bateri sepatutnya dikitar semula jika boleh. Pelupusan bateri terpakai mestilah mematuhi peraturan alam sekitar tempatan.
OSTRZEENIE
Istnieje niebezpieczestwo wybuchu w przypadku zastosowania niewaciwego typu baterii. Zuyte baterie naley w miar moliwoci utylizowa zgodnie z odpowiednimi przepisami ochrony rodowiska.
PRECAUIE
Risc de explozie, dac bateria este nlocuit cu un tip de baterie necorespunztor. Bateriile trebuie reciclate, dac este posibil. Depozitarea bateriilor uzate trebuie s respecte reglementrile locale privind protecia mediului.
. . , .
63
UPOZORNENIE
Ak batriu vymente za nesprvny typ, hroz nebezpeenstvo jej vbuchu. Batrie by sa mali poda monosti vdy recyklova. Likvidcia pouitch batri sa mus vykonva v slade s miestnymi predpismi na ochranu ivotnho prostredia.
POZOR
Zamenjava baterije z baterijo druganega tipa lahko povzroi eksplozijo. e je mogoe, baterije reciklirajte. Rabljene baterije zavrzite v skladu z lokalnimi okoljevarstvenimi predpisi.
. UYARI
Yanl trde pil takldnda patlama riski vardr. Piller mmkn olduunda geri dntrlmelidir. Kullanlm piller, yerel evre yasalarna uygun olarak atlmaldr.
O
, . , . , .
64
65
To replace the battery, follow these steps: 1. Observe the precautions in "Before You Begin" (see page 31). 2. Turn off all peripheral devices connected to the computer. Disconnect the computers power cord from the AC power source (wall outlet or power adapter). 3. Remove the computer cover. 4. Locate the battery on the board (see Figure 33). 5. With a medium flat-bladed screwdriver, gently pry the battery free from its connector. Note the orientation of the + and - on the battery. 6. Install the new battery in the connector, orienting the + and - correctly. 7. Replace the computer cover.
66
Updating the BIOS with the Intel Express BIOS Update Utility
With the Intel Express BIOS Update utility you can update the system BIOS while in the Windows environment. The BIOS file is included in an automated update utility that combines the functionality of the Intel Flash Memory Update Utility and the ease of use of Windows-based installation wizards. To update the BIOS with the Intel Express BIOS Update utility: 1. Go to the Intel World Wide Web site: http://support.intel.com/support/motherboards/desktop/ 2. Navigate to the DP55SB page, click [view] Latest BIOS updates, and select the Express BIOS Update utility file. 3. Download the file to your hard drive. (You can also save this file to a removable USB device. This is useful if you are updating the BIOS for multiple identical systems.) 4. Close all other applications. This step is required. Your system will be rebooted at the last Express BIOS Update window. 5. Double-click the executable file from the location on your hard drive where it was saved. This runs the update program. 6. Follow the instructions provided in the dialog boxes to complete the BIOS update.
67
Updating the BIOS with the ISO Image BIOS Update File or the Iflash Memory Update Utility
You can use the information in this section to update the BIOS using either the Iflash Memory Update Utility or the ISO Image BIOS update file.
You can obtain either of these files through your computer supplier or by navigating to the Intel Desktop Board DP55SB page on the Intel World Wide Web site at: http://support.intel.com/support/motherboards/desktop Navigate to the DP55SB page, click [view] Latest BIOS updates, and select the ISO Image BIOS Update or Iflash BIOS Update utility file.
Updating the BIOS with the ISO Image BIOS Update File
The ISO Image BIOS update allows for the update of an Intel Desktop Board BIOS to the latest production release regardless of the operating system installed on the computer's hard drive and without the need to remove the BIOS configuration jumper. It requires a blank CD-R, a read/writeable CD drive, and software capable of uncompressing and writing the ISO image file to CD. The image uses ISOLINUX* bootloader and automatically launches a script to upgrade the BIOS via the Iflash utility.
68
CAUTION
Do not interrupt the process or the system may not function properly. Follow these instructions to upgrade the BIOS using the ISO Image BIOS file: 1. Download the ISO Image BIOS file. 2. Using software capable of uncompressing and writing an ISO image file to CD, burn the data to a blank CD.
NOTE
Copying the ISO Image BIOS file to CD will not work. The completed CD should contain multiple files and a directory. 3. Insert the CD that was created in the CD-ROM drive of the computer to be upgraded and boot the system. 4. When the "Press ENTER to continue booting from CD-ROM" prompt appears, press the Enter key. The system will boot from the hard drive if no key is pressed within 15 seconds. 5. At the "Welcome to the Intel Desktop Board BIOS Upgrade CD-ROM" page, press any key to confirm the BIOS upgrade operation. 6. Wait for the BIOS upgrade process to complete.
CAUTION
DO NOT POWER DOWN YOUR COMPUTER before the update is complete. The update may take up to 5 minutes.
NOTE
Review the instructions distributed with the update utility before attempting a BIOS update.
69
CAUTION
Do not interrupt the process or the system may not function properly. 1. Uncompress the BIOS update file and copy the .BIO file, IFLASH.EXE, and .ITK file (optional) to a bootable USB flash drive or other bootable USB media. 2. Configure the BIOS or use the F10 option during POST to boot to the USB device. 3. Manually run the IFLASH.EXE file from the USB device and manually update the BIOS.
70
71
Loading the Intel Matrix Storage Technology RAID Drivers and Software (Required for Microsoft Windows XP Installation)
1. Begin Windows Setup by booting from the Windows installation CD. 2. At the beginning of Windows Setup, press <F6> to install a third-party SCSI or RAID driver. When prompted, insert the diskette that contains the Intel Matrix Storage Technology RAID Driver in a USB floppy disk drive. Refer to http://support.microsoft.com/kb/916196/en-us for information on supported USB floppy disk drives. Install the Intel SATA RAID Controller driver. 3. Finish the Windows installation and install all necessary drivers. 4. Install the Intel Matrix Storage Console software via the Intel Express Installer CD included with your Desktop Board or after downloading it from the Internet at http://support.intel.com/support/motherboards/desktop/. The Intel Matrix Storage Console software can be used to manage the RAID configuration.
72
Memory error
Memory error
73
Explanation
Processor was previously shutdown due to a thermal event (overheating). The firmware has detected that a CMOS battery failure occurred. The firmware has detected that a CMOS Checksum Error occurred. The firmware has detected that the system date/time has not been set. The firmware has detected that the system memory has decreased. The system chassis was opened. SERIAL PRESENCE DETECT (SPD) device data missing or inconclusive. Properly programmed SPD device data is required for reliable operation. The installed amount of memory in Channel A is not equal to the amount of memory in Channel B. Maximum memory performance is achieved with equal amounts of memory installed in each channel.
MEM_OPTIMAL_ERROR
74
75
Table 17 lists the Port 80h POST codes in hexadecimal notation. Table 17. Port 80h POST Codes
POST Code 00 01-05 10, 20, 30, 40, 50 08 09 0A, 0B 0C 0D 0E 0F 11 12 13 14 15 16 17, 18 19, 1A 1B, 1C 21 23 24 27 28 29 2A, 2B 31, 33, 34 Description ACPI S States Entering S0 state, standard Entering S1-S5 state Resuming from S1-S5 state Security Phase (SEC) Starting BIOS execution after CPU BIST SPI prefetching and caching Load BSP/APS microcode Platform program base addresses Wake up all APS Initialize NEM Pass entry point of the PEI core PEI Phase Before MRC Set bootmode, GPIO init Early chipset register programming Basic PCH init, discrete device init LAN init Exit early platform init driver SMBUS driver init Entry/Exit to SMBUS execute read/write Entry/Exit to CK505 programming Entry/Exit to PEI overclock programming MEC Memory Detection MRC entry point Reading SPD from memory DIMMs Detecting presence of memory DIMMs Configuring memory Testing memory Exit MRC driver PEI After MRC Start/finish programming MTRR settings PEIMs/Recovery Recovery has initiate, load, valid
76
POST Code 41-43 44-46 47-4C 4D-4F 50-52 58, 59 5A, 5B 5F 60-6F E4 E7 E8 E9 EB 90-95 98-9B B0-BF F8 F9
Description CPU Initialization (PEI, DXE, SMM) Begin to end CPU PEI init Begin to end CPU SMM init/relocate bases CPU DXE phase begin to end CPU DXE SMM phase begin to end I/O Buses PCI enumeration, allocation, hot plug Resetting USB bus Resetting SATA bus and all devices Unrecoverable error, start with PIC Boot Device Selection (BDS) BDS driver entry Entered DXE phase Waiting for user input Checking password Entering BIOS setup Calling legacy option ROMs Keyboard/Mouse (PS/2 or USB) Keyboard initialization Mouse initialization Fixed Media Detecting and initializing fixed media Runtime Phase/EFI Operating System Boot EFI boot service ExitBootServices EFI runtime service SetVirtualAddressMap
77
78
B Regulatory Compliance
This appendix contains the following regulatory compliance information for Intel Desktop Board DP55SB: Safety standards European Union Declaration of Conformity statement Product Ecology statements Electromagnetic Compatibility (EMC) regulations Product certifications
Safety Standards
Intel Desktop Board DP55SB complies with the safety standards stated in Table 18 when correctly installed in a compatible host system. Table 18. Safety Standards
Regulation CSA/UL 60950-1, First Edition EN 60950-1:2006, Second Edition IEC 60950-1:2005, Second Edition Title Information Technology Equipment Safety - Part 1: General Requirements (USA and Canada) Information Technology Equipment Safety - Part 1: General Requirements (European Union) Information Technology Equipment Safety - Part 1: General Requirements (International)
CAUTION
Risk of explosion if the battery is replaced with an incorrect type. Batteries should be recycled where possible. Disposal of used batteries must be in accordance with local environmental regulations. A suitable caution label is included with Intel Desktop Board DP55SB. Related Links For information about replacing the battery, go to page 61.
79
This product follows the provisions of the European Directives 2004/108/EC and 2006/95/EC.
etina Tento vrobek odpovd poadavkm evropskch smrnic 2004/108/EC a 2006/95/EC. Dansk Dette produkt er i overensstemmelse med det europiske direktiv 2004/108/EC & 2006/95/EC. Dutch Dit product is in navolging van de bepalingen van Europees Directief 2004/108/EC & 2006/95/EC. Eesti Antud toode vastab Euroopa direktiivides 2004/108/EC ja 2006/95/EC kehtestatud nuetele. Suomi Tm tuote noudattaa EU-direktiivin 2004/108/EC & 2006/95/EC mryksi. Franais Ce produit est conforme aux exigences de la Directive Europenne 2004/108/EC & 2006/95/EC. Deutsch Dieses Produkt entspricht den Bestimmungen der Europischen Richtlinie 2004/108/EC & 2006/95/EC. 2004/108/EC 2006/95/EC. Magyar E termk megfelel a 2004/108/EC s 2006/95/EC Eurpai Irnyelv elrsainak. Icelandic essi vara stenst regluger Evrpska Efnahags Bandalagsins nmer 2004/108/EC & 2006/95/EC. Italiano Questo prodotto conforme alla Direttiva Europea 2004/108/EC & 2006/95/EC. Latvieu is produkts atbilst Eiropas Direktvu 2004/108/EC un 2006/95/EC noteikumiem.
80
Regulatory Compliance
Lietuvi is produktas atitinka Europos direktyv 2004/108/EC ir 2006/95/EC nuostatas. Malti Dan il-prodott hu konformi mal-provvedimenti tad-Direttivi Ewropej 2004/108/EC u 2006/95/EC. Norsk Dette produktet er i henhold til bestemmelsene i det europeiske direktivet 2004/108/EC & 2006/95/EC. Polski Niniejszy produkt jest zgodny z postanowieniami Dyrektyw Unii Europejskiej 2004/108/EC i 2006/95/EC. Portuguese Este produto cumpre com as normas da Diretiva Europia 2004/108/EC & 2006/95/EC. Espaol Este producto cumple con las normas del Directivo Europeo 2004/108/EC & 2006/95/EC. Slovensky Tento produkt je v slade s ustanoveniami eurpskych direktv 2004/108/EC a 2006/95/EC. Slovenina Izdelek je skladen z dolobami evropskih direktiv 2004/108/EC in 2006/95/EC. Svenska Denna produkt har tillverkats i enlighet med EG-direktiv 2004/108/EC & 2006/95/EC. Trke Bu rn, Avrupa Birliinin 2004/108/EC ve 2006/95/EC ynergelerine uyar.
Recycling Considerations
As part of its commitment to environmental responsibility, Intel has implemented the Intel Product Recycling Program to allow retail consumers of Intels branded products to return used products to selected locations for proper recycling. Please consult http://www.intel.com/intel/other/ehs/product_ecology for the details of this program, including the scope of covered products, available locations, shipping instructions, terms and conditions, etc. Intel Product Recycling Program http://www.intel.com/intel/other/ehs/product_ecology
81
Deutsch Als Teil von Intels Engagement fr den Umweltschutz hat das Unternehmen das Intel Produkt-Recyclingprogramm implementiert, das Einzelhandelskunden von Intel Markenprodukten ermglicht, gebrauchte Produkte an ausgewhlte Standorte fr ordnungsgemes Recycling zurckzugeben. Details zu diesem Programm, einschlielich der darin eingeschlossenen Produkte, verfgbaren Standorte, Versandanweisungen, Bedingungen usw., finden Sie auf der http://www.intel.com/intel/other/ehs/product_ecology Espaol Como parte de su compromiso de responsabilidad medioambiental, Intel ha implantado el programa de reciclaje de productos Intel, que permite que los consumidores al detalle de los productos Intel devuelvan los productos usados en los lugares seleccionados para su correspondiente reciclado. Consulte la http://www.intel.com/intel/other/ehs/product_ecology para ver los detalles del programa, que incluye los productos que abarca, los lugares disponibles, instrucciones de envo, trminos y condiciones, etc. Franais Dans le cadre de son engagement pour la protection de l'environnement, Intel a mis en uvre le programme Intel Product Recycling Program (Programme de recyclage des produits Intel) pour permettre aux consommateurs de produits Intel de recycler les produits uss en les retournant des adresses spcifies. Visitez la page Web http://www.intel.com/intel/other/ehs/product_ecology pour en savoir plus sur ce programme, savoir les produits concerns, les adresses disponibles, les instructions d'expdition, les conditions gnrales, etc. http://www.intel.com/in tel/other/ehs/product_ecology Malay Sebagai sebahagian daripada komitmennya terhadap tanggungjawab persekitaran, Intel telah melaksanakan Program Kitar Semula Produk untuk membenarkan pengguna-pengguna runcit produk jenama Intel memulangkan produk terguna ke lokasi-lokasi terpilih untuk dikitarkan semula dengan betul. Sila rujuk http://www.intel.com/intel/other/ehs/product_ecology untuk mendapatkan butir-butir program ini, termasuklah skop produk yang dirangkumi, lokasi-lokasi tersedia, arahan penghantaran, terma & syarat, dsb.
82
Regulatory Compliance
Portuguese Como parte deste compromisso com o respeito ao ambiente, a Intel implementou o Programa de Reciclagem de Produtos para que os consumidores finais possam enviar produtos Intel usados para locais selecionados, onde esses produtos so reciclados de maneira adequada. Consulte o site http://www.intel.com/intel/other/ehs/product_ecology (em Ingls) para obter os detalhes sobre este programa, inclusive o escopo dos produtos cobertos, os locais disponveis, as instrues de envio, os termos e condies, etc. Russian , Intel Intel (Product Recycling Program) Intel . , - http://www.intel.com/intel/other/ehs/product_ecology , , , , .. Trke Intel, evre sorumluluuna bamllnn bir paras olarak, perakende tketicilerin Intel markal kullanlm rnlerini belirlenmi merkezlere iade edip uygun ekilde geri dntrmesini amalayan Intel rnleri Geri Dnm Programn uygulamaya koymutur. Bu programn rn kapsam, rn iade merkezleri, nakliye talimatlar, kaytlar ve artlar v.s dahil btn ayrntlarn grenmek iin ltfen http://www.intel.com/intel/other/ehs/product_ecology web sayfasna gidin.
83
84
Regulatory Compliance
or
or
The maximum concentrations allowed are 0.1% or 1000 ppm (except for cadmium, which is limited to 0.01% or 100 ppm) by weight of homogeneous material. Intel Desktop Board DP55SB complies with these restrictions.
85
China RoHS
China RoHS is the term used by industry generally to describe legislation implemented by the Ministry of Information Industry (MII) in the People's Republic of China for the control of pollution by electronic information products (EIP). The official title of the China RoHS regulation is Management Methods for Controlling Pollution by Electronic Information Products. China RoHS bans the same substances and has the same limits as EU RoHS. However, the China RoHS regulation requires specific product marking and a selfdeclaration of the controlled substances contained in each product. Intel Desktop Board DP55SB is a China RoHS-compliant product. The required China RoHS mark indicates the products Environmental Friendly Usage Period (EFUP). The EFUP is defined as the number of years for which listed controlled substances will not leak or chemically deteriorate while in the product. The EFUP for Intel Desktop Boards has been determined to be 10 years. The EFUP for Intel Desktop Board DP55SB is shown in Table 20. Table 20. China RoHS Environmentally Friendly Use Period Mark
Description This is an example of the symbol used on Intel Desktop Boards and associated collateral. The color of the mark may vary depending upon the application. The Environmental Friendly Usage Period (EFUP) for Intel Desktop Boards has been determined to be 10 years. Mark
86
Regulatory Compliance
The China MII stipulates that a material Self Declaration Table (SDT) must be included in a products user documentation. The SDT for Intel Desktop Board DP55SB is shown in Figure 35.
Figure 35. Intel Desktop Board DP55SB China RoHS Material Self Declaration Table
87
EMC Regulations
Intel Desktop Board DP55SB complies with the EMC regulations stated in Table 21 when correctly installed in a compatible host system. Table 21. EMC Regulations
Regulation (Class B) FCC 47 CFR Part 15, Subpart B ICES-003 Issue 4 EN55022:2006 Title Title 47 of the Code of Federal Regulations, Part 15, Subpart B, Radio Frequency Devices. (USA) Interference-Causing Equipment Standard, Digital Apparatus. (Canada) Limits and methods of measurement of Radio Interference Characteristics of Information Technology Equipment. (European Union) Information Technology Equipment Immunity Characteristics Limits and methods of measurement. (European Union) Australian Communications Authority, Standard for Electromagnetic Compatibility. (Australia and New Zealand) Limits and methods of measurement of Radio Disturbance Characteristics of Information Technology Equipment. (International) Information Technology Equipment Immunity Characteristics Limits and Methods of Measurement. (International) Voluntary Control for Interference by Information Technology Equipment (Japan) Korean Communications Commission Framework Act on Telecommunications and Radio Waves Act. (South Korea). Bureau of Standards, Metrology and Inspection. (Taiwan)
EN55024:1998 EN55022:2006 CISPR 22:2005 +A1:2005 +A2:2006 CISPR 24:1997 +A1:2001 +A2:2002 VCCI V-3/2007.04, V-4/2007.04 KN-22, KN-24 CNS 13438:2006
Japanese Kanji statement translation: This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual.
88
Regulatory Compliance
Korean Class B statement translation: This is household equipment that is certified to comply with EMC requirements. You may use this equipment in residential environments and other non-residential environments.
If the power supply and other modules or peripherals, as applicable, are not Class B EMC compliant before integration, then EMC testing may be required on a representative sample of the newly completed computer.
89
Product Certifications
Board-Level Certification Markings
Intel Desktop Board DP55SB has the product certification markings shown in Table 22. Table 22. Product Certification Markings
Description UL joint US/Canada Recognized Component mark. Includes adjacent UL file number for Intel Desktop Boards: E210882. FCC Declaration of Conformity logo mark for Class B equipment. Includes Intel name and DP55SB model designation. Mark
CE mark. Declaring compliance to European Union (EU) EMC directive and Low Voltage directive.
Australian Communications Authority (ACA) and New Zealand Radio Spectrum Management (NZ RSM) C-tick mark. Includes adjacent Intel supplier code number, N-232. Japan VCCI (Voluntary Control Council for Interference) mark.
S. Korea KCC (Korean Communications Commission) mark. Includes adjacent KCC certification number: CPU-DP55SB (B).
Taiwan BSMI (Bureau of Standards, Metrology and Inspections) mark. Includes adjacent Intel company number, D33025. Printed wiring board manufacturers recognition mark. Consists of a unique UL recognized manufacturers logo, along with a flammability rating (solder side). V-0
90
Regulatory Compliance
91
92