Siemens Parameters
Siemens
Range
Unit
Default
Parameter
current setting
BB900/DCS1800
same as BCC
TSC
CH Type MAIO
Tch full rate/Tch half rate 01/Tch half rate 0/SDCCH8/Main BCCH/Combined BCCH/BCH/BCCH+ CBCH/PBCCH+PDT CH/PCCCH+PDTCH /PDTCH/Dynamic PDTCH 0~(N-1)
1or2TRX: 1SDCCH/8; 3or4TRX: 2SDCCH/8; 5or6TRX: 3SDCCH/8. And SD dynamic allocation allowed must be Yes CHTYPE MAIO MAIO
Site
Carrier Configuration Table
Static TRX Power Class Carrier Power Type HW-IUO Property TRX Priority
0~6(BTS30,0407 Version), 0~10 (0529 Version), 0~13 (microcell) grade 40W/60W/Default OverLaid Cell /UnderLaid / None 0~7
0 Default None 0
PWRRED
CONCELL
Cell
System Information Table 0 1111000000 111111 Yes 10 Sys information 1~6,2bis,2ter,5bi s,5ter
Sys information 1~6, 2bis, 2ter, 5bis, 5ter Yes / No 0~255 min.
MS MAX Retrans
1,2,4,7 Level 1/ 2/ 3/ 4/ 5/ 6/ 7/ 8/ 9/ 10 Forbidden Level 11/ 12/ 13/ 14/ 15 Forbidden 1024,512,256,128,bit map Yes / No Yes / No Allowed/Mandatory/F orbidden
times
this parameter set more biger , and Call setup successful rate is more higher , but the load of RACHand SDCCH is also heavier. MAXRETR
1,4
Common Access Control Class Special Access Control Classl Cell Channel Description Format ATT PWRC UL DTX
ACC ACC
TRUE TRUE
NSLOTST CB
BS_AG_BLKS_RES
02 (one combined CCCH), 07(others) block one no-combined CCCH/ one combined CCCH/ two no-combined CCCHs/ three nocombined CCCHs/ four no-combined CCCHs
CCCH_CONF BA_PA_MFRAMS
noncombined CCCH 2
fit in with the quantity of TRX in the cell 2-9 CCCH multiframes NFRAMEPG 2
T3212
0255
6min.
15
40,20
4~64
480ms
52
4,3,5,7
MS_ TXPWR_MAX_CCH
020
grade
0(1800),5(900)
MSTXPWRMX
0,5
RXLEV_ACCESS_MIN ACS
0~63 Yes / No
grade
8 No
8,10
Yes / No
No
EHRACT
FALSE/true
CRH
0~14
dBm
Cell reselection hysteresis, step=2;4(normal) , 8~10 (urban) CELLRESH only use in cell broadcast operatting only use in cell broadcast operatting Cell Reselect Parameters Indication
34
CBCH CH Description
6BIT
SMSCBUSE
SMSCBUSE
PI CBQ
Yes / No Yes / No
Yes No
CRESPARI 0,1
Cell Bar Qualify CBQ Cell Reselect Offset, step=2dB, 0~63 means 0~126dB CRESOFF Cell Reselect Temporary Offset, 0~6 is 0~60 dB, 7 is infinite
CRO
0~63
TO
0~7
TEMPOFF
0 No YES 1
Cell Reselect Penalty Time, 0~30 is 20~620ms, when PT=31, C2=C1CRO PENTIME EARCLM 0, 2, 4, 6dBm PWROFS
TRUEfalse
0~3
03
NT 12K FULL RATE, NT 12K HALF RATE, NT 12K, NT 6K, T 9.6K, T 4.8K, T 2.4K, T 1.2K, T 600 BITS, T 1200/75 Not support,A5/1~A5/7 Not hopping/ Baseband hopping/ Radio frequency hopping Yes / No Yes / No Not switchover, Switchover promptly, Switchover when ckeck resource
0110111000 10000000
SPEED145 ENCALSUP
NOENCR&GSMV1
BBHOP/SYNHOP
TRUE
TRX iding function control Cell Allocation Table ARFCN 0 ARFCN 63 BA1(BCCH) Table BCCH of NCell 1 BCCH of NCell 32 BA2(SACCH) Table BCCH of NCell 0 BCCH of NCell 32
CALLF01 . CALLF63
Cell Attribute Table Interf. Band Thrsh. 0 Interf. Band Thrsh. 1 Interf. Band Thrsh. 2 Interf. Band Thrsh. 3 Interf. Band Thrsh. 4 Interf. Band Thrsh. 5
110 105 98 90 87 85
INTAVEPR INTAVEPR#1 INTAVEPR#2 INTAVEPR#3 INTAVEPR#4 INTAVEPR#5 period of SACCH=480ms INTAVEPR period of SACCH=480ms RDLNKTBS RADIOMG PCCCHLDI TCCCHLDI NY1 LAPDOVLT grade-110= dBm; 5(BTS20,BTS22 C),16(BTS3X) RACHBT RACHLAS PWRREDSS T200 T200 T200 T200 T200 T200 T200
1~31
480ms
20
8-4-8-14-20
SACCH Multi_Frames Radio Resource Report Period CCCH Load Indication Period CCCH Load Thrsh. Max Resend Times of Phy. Info. OverLoad Indication Period
480ms s s % times s
31 10 15 100 100 15
RACH Busy Thrsh. Average RACH load TS number Max RC Power Reduction T200 SDCCH(5ms) T200 FACCH/F T200 FACCH/H T200 SACCH TCH SAPI0 T200 SACCH TCH SAPI3 T200 SACCH SDCCH T200 SDCCH SAPI3 T3105
0~63 0~65535 0~255 50~100 40~100 40~100 120~200 120~200 50~100 50~100 0~255
grade timeslot step=2dB 5ms 5ms 5ms 10ms 10ms 10ms 10ms 10ms
DB2
T3105
62(Normal cell), 63(Single timeslot extended cell), 219(Double timeslot extended cell) EXCDIST
ms10-4,2,8,10
MAX TA
0~127
550m
63
FALSE
Frame start time Paging Times Random Access Error Thrsh. Power Class RACH Min. Access Level DC bias voltage Thrsh.
1~8 0~255
times
3 180 5 5
0~63
grade
Cell Extension Type Cell Extension Offset Diversity LNA bypass permitted Cell Call Control Table TCH Immediate Assignment Immediate Assignment Opt. Immediate Assign to Other Cell Assign to Other Cell TCH Assignment Retry Short message uplink disabled Short message downlink disabled OM start intra-cell HO OM start inter-cell HO(intraBSC) OM start inter-BSC HO TCH flow alarm RF CH abnormal release retry Abis flow control permitted
km
STDCELL 32
Yes / No Yes / No Yes / No Yes / No Yes / No Yes / No Yes / No Yes / No Yes / No Yes / No Yes / No Yes / No Yes / No Select circuit pool function,Deselect circuit pool function,Dystem auto~select Yes / No 3~50 0~100 100ms %
Abis flow control permitted Direct Retry Cell Call Control Para. Table T3101(100ms) Assign-TCH idle rate Thrsh.
No Yes 30 80 No Use
ENFORCHO t3101
ENABLE HLFSEC-6
SDCCHCONGTH 70,80,85,100
Assign-TCH re-Estb. rate thrsh. TCH Flow Control Start Thrsh. Max Assignment Retry Times Ilde TCH Thrsh. for SD to TCH HO Max. radioCH release retry times
80 2 2 80 1
SDCCHCONGTH 70,80,85,100
No Use
Service Type Req.(SD to TCH HO) Out HO Request Resend Interval Out BSC HO Req. Resent Times Syst. Delay Frame No.Adjust Response On Out BSC HO Req.
MSC service request,Location update request,Paging response,MSC service re~establish request,Unknow 0~15 s 0~3 times number Yes / No
ENFORCHO BSCTQHO
ENABLE HLFSEC-120
INTERCH
TRUE
Handover
Handover Control Data Table HO Algorithm Min Interval for TCH HOs Min Interval for SD HOs HUAWEI / GSM0508 1~60 s 1~60 s HUAWEI 6 2 No No No
Min Interval for Consecutive HOs Min Interval for Urgent HOs Co-BSC/MSC Adj. SD HO Allowed Penalty Allowed IntraCell HO Allowed Load HO Allowed MS fast moving HO allowed Rx_Level_Drop HO Allowed PBGT HO Allowed
1~60 1~60 Yes / No Yes / No Yes / No Yes / No Yes / No Yes / No Yes / No Yes / No
s s
10,12,14,15,16
MS Power Prediction after HO MR. Preprocessing Transfer Original MR. Transfer BS/MS power class
no No No Yes
No, Yes(15:1)
No No No No
s Parameters
Default
Unit
Same/Not
Question
same same
same same
same
10
255
same
10
same
same
same
same
same
not
not
same same
same
same
0 TRUE 0
same
not same
BBHOP
Huawei Special same same same Huawei Special Huawei Special Huawei Special Huawei Special Huawei Special Huawei Special
same
20
MS10-4
not not same same same same same same same same same
TRUE
same
Huawei Special Huawei Special Huawei Special not 6 same HuaWei special
STDCELL
same not Huawei Special Huawei Huawei Huawei Huawei Huawei Huawei Huawei Huawei Huawei Huawei Huawei Huawei Huawei Special Special Special Special Special Special Special Special Special Special Special Special Special
For inter-cell HO