Anda di halaman 1dari 26

ICON Product Guide

PLTC / ITC Instrumentation and Control Cables

The Quality Connection

Product range

Telecommunication cables Data- and Bus cables (copper and fiber optic) Mining cables Cables for special applications Instrumentationand control cables Thermocouple extension and compensating cables Power cables (low and medium voltage)

Table of contents
Table of contents

Introduction of Standards and Product Programme

Page

Group 4: ICON Instrumentation Cables acc. to UL Common types UL listed as PLTC/ITC acc. to UL 13 / 2250 Technical Data Construction Electrical Data Common types UL listed as TC acc. to UL 1277 Technical Data Construction Electrical Data 300 V 600 V Page Page Page Page Page Page Page E1 E2 E3 E4 E6 E7 E8

Group 5: ICON Control Cables acc. to UL 1277 Common types Technical Data Construction Electrical Data 600 V Page Page Page Page F1 F2 F3 F4

Conversion of General Units Conductor Comparison AWG - Metric Color code of standardized Product Programme Identification of Instrumentation and Thermocouple Cables

Page Page Page Page

G1 G2 G3 G4

Note: LEONI Kerpen GmbH can not be held responsible in any form whatsover for any information provided by this publication.
Issue 20070924 LEONI Kerpen 



LEONI Kerpen

 ntroduction of Standards I and Product Programme


The Standards
The product programme Instrumentation Cable ICON covers products which are based on the European standard EN 50288-7 and the US-American standards UL 13, UL 2250 and UL1277. This product programme gives extensive coverage to the requirements of the different Installation and Safety Regulations which are applied for measurement, control and monitoring systems in industrial plants. As a result the user has a product programme at his disposal for applications world wide.

EN 50288-7
The European standard EN 50288-7 represents the first standard for instrumentation cables for onshore applications which has been created by a recognised international standardisation organisation. The future meaning of this standard will be underlined by the fact that it will also become national standard in all CENELEC attached countries (at present 28). National standards conflicting with the EN-Standard will have to be withdrawn after a transitional period.

UL 13, UL 2250 and UL 1277


Instrumentation, Control and Thermocouple extension cables according to above standards have to be applied in those systems, where Installation and Safety regulations are based on the National Electrical Code (NEC). The NEC Handbook is published by the National Fire Protection Association a leading US standardisation for safety, particularly for fire protection. As installation guide it is mandatory in the USA, however, it is also practised in some other countries. Instrumentation, Control and Thermocouple extension cables will thereby meet the following standards and types: 300 V   Power Limited Tray Cable (PLTC) acc. to UL 13 Instrumentation Tray Cable(ITC) acc. to UL 2250

600 V Tray Cable (TC) acc. to UL 1277

LEONI Kerpen



PLTC / ITC Cables

LEONI Kerpen





LEONI Kerpen

Group 4:

Instrumentation Cable
acc. to UL 13/2250

LEONI Kerpen

 E1

Instrumentation Cable PLTC/ITC Common Types

acc. to UL 13 /2250 300 V

Single & Multipair and Multi-Triple, individual and/or collective shield, PVC-jacket unarmoured, armoured
Technical Data Type of insulation/jacket Type of cabling elements No. of cabling elements Conductor sizes PVCw/PVCw Pair, Triple, PiMF, TiMF 1, 2, 4, 6, 8, 10, 12, 16, 20, 24, 36 AWG 20/7, AWG 18/7, AWG 16/7 XLPE/PVCw Pair, Triple, PiMF, TiMF 1, 2, 4, 6, 8, 10, 12, 16, 20, 24, 36 AWG 20/7, AWG 18/7, AWG 16/7

1. Unarmoured types Laying Bending radius

RE-Yw(St)Yw-fl RE-2X(St)Yw-fl Recommended for indoor and outdoor installation, on Recommended for indoor and outdoor installation, on racks, trays, in conduits, in dry and wet locations racks, trays, in conduits, in dry and wet locations 7.5 x cable 7.5 x cable

2. Armoured types Laying Bending radius Temperature range during operation during installation Reaction to fire Flame propagation a) Test on single cable b) Test on bunched cables Sunlight resistance Oil resistance Application

RE-Yw(St)YwSWAYw-fl Recommended for outdoor installation, on racks, trays, in conduits, in dry and wet locations 10 x cable

----

- 30 C up to 105 C - 5 C up to 50 C

- 30 C up to 90 C - 5 C up to 50 C

IEC 60332-1 IEC 60332-3 part 24 (Cat. C), UL 13 vertical tray tested UL 1581 Section 1200 ICEA S-82-552 For transmission of analogue and digital signals in instrument and control systems; allowed for use in hazardous classified locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources, e.g. public mains electricity supply

 E2

LEONI Kerpen

Instrumentation Cable PLTC/ITC Common Types

acc. to UL 13 /2250 300 V

Single & Multipair and Multi-Triple, individual and/or collective shield, PVC-jacket unarmoured, armoured
Construction Product Type Conductor size conductor design Unarmoured Types Plain annealed copper; 7 stranded acc. UL 13 AWG 20/7 7 x 0.320 AWG 18/7 7 x 0.404 Armoured Types Plain annealed copper; 7 stranded acc. UL 13 AWG 16/7 7 x 0.510

mm

Insulation materials

Cross linked Polyethylene XLPE or Polyvinylchloride heat resistant PVCw

Polyvinylchloride heat resistant PVCw

Cabling element 1) without ind. shield with ind. shield Pair, Triple PiMF, TiMF Pair, Triple PiMF, TiMF

Individual shield Wrapping

Aluminium/Plastic-tape over stranded tinned copper drain wire, plastic tape under and above shield at least one plastic tape above cable core at least one plastic tape above cable core

Overall shield

Aluminium/Plastic tape over stranded tinned copper drain wire

Inner jacket

--

PVC, black

Armouring

--

Galvanized steel wire armouring; wire depending on cable- under armouring, at least 0.9 mm PVCw black or blue for intrisically safe systems

Outer jacket Colour

Marking

LEONI KERPEN ICON no. of elements size type of shield (UL) PLTC / ITC 300 V temperature rating sun res Length Marking

1)

Colour codes of cabling elements: see appendix II LEONI Kerpen  E3

Instrumentation Cable PLTC/ITC Common Types

acc. to UL 13 /2250 300 V

Single & Multipair and Multi-Triple, individual and/or collective shield, PVC-jacket unarmoured, armoured
Electrical Data at 20C Properties Conductor sizes Conductor resistance Insulation resistance at 15.6 C PVCw -insulation XLPE -insulation Inductance Mutual capacitance PVCw-insulation Pair, Triple 1), 2) PiMF, TiMF XLPE-insulation Pair, Triple 1), 2) PiMF, TiMF Test voltage Core/core Core/shield Operating voltage (Urms) (Urms) (Urms) max. V V V 1500 1500 300 1500 1500 300 1500 1500 300 300 V Character nom. max Unit mm /km AWG 20/7 35.78 Values AWG 18/7 22.78 AWG 16/7 14.25

min. min. max.

Mxkm Mxkm mH/km

30.5 810 1

30.5 810 1

30.5 810 1

max. max.

nF/km nF/km

132 187

132 187

132 187

max. max.

nF/km nF/km

80 120

80 120

80 120

1) 2)

Values for cables with 1 element correspond to those for PiMF and TiMF resp. Values for cables with 2 up to 4 elements + 20%

 E4

LEONI Kerpen

Group 4:

Instrumentation Cable
acc. to UL 1277

LEONI Kerpen

 E5

Instrumentation Cable TC Common Types


Single & Multipair and Multi-Triple, individual and/or collective shield, PVC-jacket unarmoured
Technical Data Type of insulation/jacket Type of cabling elements No. of cabling elements Conductor sizes Unarmoured types Laying Bending radius Temperature range during operation during installation Reaction to fire Flame propagation a) Test on single cable b) Test on bunched cables Sunlight resistance Oil resistance Application PVCwNC/PVCw Pair, Triple, PiMF, TiMF 1, 2, 4, 6, 8, 12, 24, 36 AWG 18/7, AWG 16/7, AWG 14/7 RE-Yw4Y(St)Yw-fl PVCw/PVCw Pair, Triple, PiMF, TiMF 1, 2, 4, 6, 8, 12, 24, 36 AWG 18/7, AWG 16/7, AWG 14/7 RE-Yw(St)Yw-fl

acc. to UL 1277 600 V

XLPE/PVCw Pair, Triple, PiMF, TiMF 1, 2, 4, 6, 8, 12, 24, 36 AWG 18/7, AWG 16/7, AWG 14/7 RE-2X(St)Yw-fl

Recommended for indoor and outdoor installation, on racks,trays, in conduits, in dry and wet locations, for direct burial 10 x cable 7.5 x cable 7.5 x cable

- 30C up to + 90C - 5C up to + 50C

- 30C up to + 90C - 5C up to + 50C

- 30C up to + 90C - 5C up to + 50C

IEC 60332-1 IEC 60332-3 part 24 (Cat. C), UL 1685 vertical tray test, IEEE 383 vertical tray test UL 1581 Section 1200 ICEA S-82-552 For transmission of analogue and digital signals in instrument and control systems; UL-listed tray cable in compliance with NEC article 336, for use in hazardous classified locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources, e.g. public mains electricity supply

 E6

LEONI Kerpen

Instrumentation Cable TC Common Types


Single & Multipair and Multi-Triple, individual and/or collective shield, PVC-jacket unarmoured
Construction Product Types Conductor size conductor design Insulation materials AWG 18/7 7 x 0.404 Unarmoured Types

acc. to UL 1277 600 V

Plain annealed copper; 7 stranded acc. UL 13 AWG 16/7 7 x 0.490 AWG 14/7 7 x 0.620

mm

Polyvinylchloride PVC heat resistant PVCw with nylon jacket NC or Polyvinylchloride PVC heat resistant PVCw or Cross linked Polyethylene XLPE

Cabling element without ind. shield with ind. shield Individual shield Wrapping Overall shield Outer jacket Colour Marking

Pair, Triple PiMF, TiMF Aluminium/Plastic-tape over stranded tinned copper drain wire plastic tape under and above shield at least one plastic tape above cable core Aluminium/Plastic tape over stranded tinned copper drain wire PVCw black or blue for intrinsically safe systems LEONI KERPEN ICON no. of elements size type of shield (UL) TC type of conductor / jacket material 600 V temperature rating sun res dir bur length marking

LEONI Kerpen

 E7

Instrumentation Cable TC Common Types


Single & Multipair and Multi-Triple, individual and/or collective shield, PVC-jacket unarmoured
Electrical Data at 20C Properties Conductor sizes Conductor resistance Insulation resistance at 15 C 1) PVCw -insulation XLPE -insulation Inductance Mutual capacitance PVCw-insulation with NC Pair, Triple 2), 3) PiMF, TiMF PVCw-insulation Pair, Triple 2), 3) PiMF, TiMF XLPE-insulation Pair, Triple 2), 3) PiMF, TiMF Test voltage Core/core (Urms) Core/shield (Urms) Operating voltage (Urms) max. 600 V Character nom. max Unit mm /km AWG 18/7 22.78

acc. to UL 1277 600 V

Values AWG 16/7 14.25 AWG 14/7 8.94

min. min. max.

Mxkm Mxkm mH/km

175 810 1

175 810 1

175 810 1

max. max.

nF/km nF/km

155 210

155 210

155 210

max. max.

nF/km nF/km

125 170

125 170

125 170

max. max.

nF/km nF/km

75 120

75 120

75 120

V V V

2000 4) 2000 4) 600

2000 4) 2000 4) 600

2000 4) 2000 4) 600

1) 2) 3)

in Water Values for cables with 1 element correspond to those for PiMF and TiMF resp. Values for cables with 2 up to 4 elements + 20% 3000 V for XLPE-insulated Types

4)

 E8

LEONI Kerpen

Group 5:

Control Cable acc. to UL 1277

Control Cable TC 600 V

plain stranded copper conductors, cores, overall static screen

PVC-insulation, PVC-jacket

PVC/NC-insulation, PVC-jacket

XLPE-insulation, PVC-jacket

unarmoured

unarmoured

unarmoured

LEONI Kerpen

 F1

Control Cable TC Common Types

acc. to UL 1277 600 V

Multi core, collective shield, PVC-jacket armoured


Technical Data Type of insulation/jacket Type of cabling elements No. of cabling elements Conductor sizes Unarmoured types Laying PVCwNC/PVCw Cores 2, 3, 4, 5, 7, 10, 12, 16, 21, 25 AWG 18/7, AWG 16/7, AWG 14/7 RE-Yw4Y(St)Yw-fl PVCw/PVCw Cores 2, 3, 4, 5, 7, 10, 12, 16, 21, 25 AWG 18/7, AWG 16/7, AWG 14/7 RE-Yw(St)Yw-fl XLPE/PVCw Cores 2, 3, 4, 5, 7, 10, 12, 16, 21, 25 AWG 18/7, AWG 16/7, AWG 14/7 RE-2X(St)Yw-fl

Recommended for indoor and outdoor installation, on racks,trays, in conduits, in dry and wet locations, for direct burial 10 x cable 7.5 x cable 7.5 x cable

Bending radius Temperature range during operation during installation Reaction to fire Flame propagation a) Test on single cable b) Test on bunched cables Sunlight resistance

- 30C up to + 90C - 5C up to + 50C

- 30C up to + 90C - 5C up to + 50C

- 30C up to + 90C - 5C up to + 50C

IEC 60332-1 IEC 60332-3 part 24 (Cat. C), UL 1685 vertical tray test, IEEE 383 vertical tray test UL 1581 Section 1200

Oil resistance Application

ICEA S-82-552 For transmission of analogue and digital signals in instrument and control systems; UL-listed tray cable in compliance with NEC article 336, for use in hazardous classified locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources, e.g. public mains electricity supply

 F2

LEONI Kerpen

Control Cable TC Common Types

acc. to UL 1277 600 V

Multi core, collective shield, PVC-jacket armoured


Construction Product Types Conductor size conductor design (mm) AWG 18/7 7 x 0.404 unarmoured types Plain annealed copper; 7 stranded acc. UL 13 AWG 16/7 7 x 0.490 AWG 14/7 7 x 0.620

Insulation materials

Polyvinylchloride PVC heat resistant PVCw with nylon jacket NC or Polyvinylchloride PVC heat resistant PVCw or Cross linked Polyethylene XLPE Core at least one plastic tape above cable core Aluminium/Plastic tape over stranded tinned copper drain wire PVCw, black or blue for intrinsically safe systems

Cabling element Wrapping Overall shield Outer jacket Colour Marking

LEONI KERPEN ICON no. of elements size type of shield (UL) TC type of conductor/ jacket material 600 V temperature rating sun res dir bur length marking

LEONI Kerpen

 F3

Control Cable TC Common Types

acc. to UL 1277 600 V

Multi core, collective shield, PVC-jacket armoured


Electrical Data at 20C Properties Conductor sizes 600 V Character nom. Unit mm AWG 18/7 Values AWG 16/7 AWG 14/7

Conductor resistance

max

/km

22.78

14.25

8.94

Insulation resistance at 15 C 1) PVCw -insulation XLPE -insulation PVCwNC -insulation Inductance Test voltage Core/core Core/shield Operating voltage

min. min. min. max

Mxkm Mxkm Mxkm mH/km

175 810 205 1

175 810 205 1

175 810 205 1

(Urms) (Urms) (Urms) max.

V V V

2000 2) 2000 2) 600

2000 2) 2000 2) 600

2000 2) 2000 2) 600

1) 2)

in Water

3000 V for XLPE-insulated Types

 F4

LEONI Kerpen

Table 1: Conversion of General Units


Length
1 mil 1 inch (in) 1 foot (ft) 1 yard (yd) 1 mile (mi.) 1 statute mile (mi.) 1 intern naut. mile (sm) = = = = = = = = = = = = = = = = 0.0254 25.4 0.305 0.914 1.61 1.61 1.852 16.39 0.0283 0.765 159 3.79 4.55 0.1 38 4.448 9964 mm mm m m km km km cm3 m3 m3 l l l

Area
1 1 1 1 1 1 circ. mil (CM) MCM square inch (in2) square foot (ft )
2

= = = = = =

0.0005067 0.5067 645.16 0.0929 0.836 2.59

mm2 mm2 mm2 m2 m2 km2

square yard (yd2) square mile (sq.mi.)

Volume
1 cubic inch (m3) 1 cubic foot (ft )
3

1 cubic yard (yd3) 1 barrel 1 US gallon (US gal) 1 UK gallon (UK gal)

Force
1 poundal (pdl) 1 pound-force (lbf) 1 Brit.ton-force N N N

Mass
1 1 1 1 ounce (oz) pound (lb) Brit.ton (long ton) US ton (short ton) Brit.therm.unit (B U) Brit.therm.unit N/m2 N/m2 N/m2 at = = = = = = 0.0284 0.454 1016 907 1055 0.000293 kg kg kg kg J kWh

Power
1 horsepower (H.P.) = 0.746 kW

Energy
1 1

Pressure
1 bf/in2 (psi) 1 lbf/ft
2

= = = = = = = = = =

0.06895 0.000479 0.0000532 0.703 0.62 1.61 0.62 3.28 3.28 3.28

bar bar bar kp/cm2 F/km M x km dB/km pF/m dB/km /km

= = = =

6.895 47.9 5.32 0.0703

1 lbf/yd2 1 lbf/in2 (psi) 1 f per mile 1 M per mile 1 decibel per mile 1 pf per foot 1 decibel per 1000 ft 1 per 1000 ft

Electrical Unit per Length

Abbreviations for Multiples and Submultiples


prefix Tera Giga Mega Kilo Hekto Deka abridged mark T G M k h da power 1012 10 10 10
9

multiple name billion * milliard * million thousand hundred ten

prefix Piko Nano Mikro Milli Zenti Dezi

abridged mark p n m c d 10
1

power 1012 10 10
9

submultiple name billionth * milliardth * millionth thousanth hundredth tenth

106
3

106
3

102
1

102

* In United States 109 means a billion and 1012 means a trillion

LEONI Kerpen

 G1

Table 2: Conductor Comparison AWG - Metric


Solid plain annealed copper conductors
Conductor Size EN 50288-73) AWG 30 28 26 24 22 --20 --18 --16 --14 --12 --Metric1) (mm) 0.051 0.081 0.128 0.205 0.324 0.5 0.517 0.75 0.82 1 1.3 1.5 2.1 2.5 3.3 4 No. of wires 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Conductor- (mm) 0.254 0.320 0.404 0.511 0.643 0.8 0.813 1.0 1.02 1.13 1.29 1.37 1.63 1.76 2.05 2.26 (/km) ----------36.8 --25.0 --18.5 --12.3 --7.56 --4.70 (/1000 ft) ----------11.2 --7.6 --5.6 --3.76 --2.31 --1.43 (/km) 361 228 154 97.6 56.3 --35.2 --22.3 --14.0 --8.79 --5.52 --(/1000 ft) 110 69.3 46.9 29.7 17.2 --10.7 --6.8 --4.3 --2.67 --1.68 --Electrical Resistance2) UL 134)

Stranded plain annealed copper conductors


Conductor Size EN 50288-73) AWG 24 22 --20 --18 --16 --14 --12 --Metric
1)

Electrical Resistance2) UL 134) (/km) 91.1 57.6 --35.8 --22.8 --14.2 --8.94 --5.63 --(/1000 ft) 27.8 17.6 --11.0 --6.9 --4.36 --2.72 --1.72 --Conductor- (mm) 0.579 0.729 0.9 0.919 1.11 1.16 1.29 1.46 1.59 1.85 2.01 2.32 2.58 (/km) ----36.8 --25.0 --18.5 --12.3 --7.56 --4.70 (/1000 ft) ----11.2 --7.6 --5.6 --3.76 --2.31 --1.43

No. of wires 7 7 7 7 7 7 7 7 7 7 7 7 7

(mm) 0.205 0.327 0.5 0.517 0.75 0.82 1 1.3 1.5 2.1 2.5 3.3 4

1) 2) 3) 4)

Sizes acc. to EN 50288-7 printed in blue The value for the electrical resistance is given for 20C (68.0 F) The value for the electrical resistance acc. to EN 50288-7 is for the finished cables with multipairs/triples The value for the electrical resistance acc. to UL 13 is calculated for one pair/triple and an assembly of pairs/triples LEONI Kerpen

 G2

Color Code of Instrumentation and Control Cables acc. to UL


Color code of standardized Product Programme

Cabling element Core 1) Rated voltage 300 V


-black/white continuously numbered on white core 1, 2, 3.. for multi-element cables, starting with 1 in the centre black/white/red continuously numbered on white core 1, 2, 3.. for multi-element cables, starting with 1 in the centre

Pair 2)

Triple 2)

600 V

black continuously numbered 1, 2, 3 .. for multi-core cables, starting with 1 in the centre

black/white

black/white/red

continuously numbered on blue core continuously numbered on white 1, 2, 3.. for multi-element cables, starting with 1 in the centre core 1, 2, 3.. for multi-element cables, starting with 1 in the centre

1) 2)

Communication wire principially applied as last element in the outer layer Identification scheme for elements with and without individual shield

Other color codes on request

LEONI Kerpen

 G3

Identification of Instrumentation and Thermocouple Cables


Type Designations of KERPENs Instrumentation- and Thermocouple Cable read as follows:
Type abbreviation code No. of cabling elements Type of cabling element Conductor size in mm (stranded conductors) or conductor diameter in mm (solid conductors)

followed by (where and when applicable): Type of conductor material (for Thermocouple cable only, see Table 1) Abbreviation sign for cables with Circuit Integrity Properties Individual shielding of pairs and triples resp. Rated Voltage Standard

Abbreviation Code
RERT -v Y Yw Yv 2Y 2X H 2G 4Y (ST) (L) C K PiMF TiMF (C) Cable Type Instrumentation and Instrumentation Control Cable resp. Thermocouple Extension or Compensating Cable Metal cladding of conductor Copper conductor, tinned Insulation and/or jacket materials Insulation, inner or outer jacket of Polyvinylchloride (PVC) Insulation, inner or outer jacket of heat resistant Polyvinylchloride (PVCw) Outer jacket of Polyvinylchloride of increased thickness Insulation, inner or outer jacket of Polyethylene (PE) Insulation of crosslinked Polyethylene (XLPE) Inner or outer jacket of halogen-free, flame retardant compound (LSZH) Insulation of silicone (Sil) Covering of Polyamide (Nylon) Shielding Static shield of Aluminium laminated plastic tape Longitudinally applied Aluminium foil, one or both sides plastic coated Braid of tinned or untinned copper wires over cable core Wrapping of copper foils Pair in Metal Foil Triple in Metal Foil Braid of tinned or untinned copper wires over single cabling element SWA RG FG B Q Armour Galvanized round steel wires Galvanized round steel wires with counter helix of galvanized steel tape Galvanized flat steel wires with counter helix of galvanized steel tape Double layer of galvanized steel tapes Braid of galvanized round steel wires M Mz Metal jacket Jacket of lead Jacket of lead alloy

CI

Other properties Circuit Integrity (Fire resistant)

-fl
F

Increased flame retardancy; requirements for IEC 60332-3-24 (cat.C) fulfilled 1)


Cable core petrojelly filled

1)

This property will be indicated on the outer jacket of PVC-jacketed cables with the marking RP LEONI Kerpen

 G4

Type of Cabling Elements


The type of cabling elements are indicated by figures resp. by figures with an additional information for individual shielded cabling elements Core Pair Triple Individual shielded pair Individual shielded triple no figure 2 3 2 PiMF 3 TiMF

Indication Examples:
Instrumentation cable RE, 24 triples 3, conductor size 1.3 mm, insulation of PE 2Y, individual TiMF and overall shield (St), inner jacket of PVC Y, lead jacket M, inner jacket of PVC Y, steel wire armour SWA, outer jacket of PVC Y-fl, rated voltage 300 V, standard EN 50288-7
RE-2Y(St)YMYSWAY-fl 24 x 3 x 1.3 mm TiMF 300 V EN 50288-7

Thermocouple extension RT-, 8 pairs 2, conductor diameter 0,8 mm, conductor material KX, insulation of heat resistant PVC Yw, overall shield (St), inner jacket of heat resistant PVC Yw, steel wire armour SWA, outer jacket of heat resistant PVC Yw, rated voltage 300 V, standard EN 50288-7
RT-Yw(St)YwSWAYw-fl 8 x 2 x 0.8 mm KX 300 V EN 50288-7

Instrumentation control cable RE-, halogen-free with Circuit Integrity CI, 8 cores, conductor size 2.5 mm, insulation of XLPE 2X, overall shield (St), outer jacket of halogen-free, flame retardant compound H, rated voltage 500 V, standard EN 50288-7
RE-2X(St)H 8 x 2.5 mm CI 500 V EN 50288-7

Instrumentation cable RE, 12 pairs 2, conductor size 1.5 mm, insulation of XLPE 2X, individual shield PiMF, Multi layer jacket (L)2Y, steel wire armour SWA, outer jacket of PE 2Y, rated voltage 300 V, standard EN 50288-7
RE-2X(L)2Y4YSWA2Y 12 x 2 x 1.5 mm PiMF 300 V EN 50288-7

Instrumentation cable RE, 24 triples 3, conductor size AWG 20/7, insulation of heat resistant PVC Yw, individual shield TiMF and overall shield (ST), outer jacket of heat resistant PVCw Yw, rated voltage 300 V standard UL 13
RE-Yw(ST)Yw-fl 24 x 3 x AWG 20/7 TiMF 300 V UL 13

LEONI Kerpen

 G5

LEONI Kerpen GmbH Business Unit Industrial Projects

Zweifaller Strasse 275-287 52224 Stolberg Germany Phone +49 (0)2402-17-307 Fax +49 (0)2402-75590 E-Mail info@leoni-kerpen.com www.leoni-kerpen.com