BULLETIN 4820
July 2011
Construction Features
Cast aluminum or
Steel panel with
Pre-punched mounting
Motor supports are
galvanized steel.
of
heavy-gauge
Fans
Pre-engineered
installation.
accessories
to
accommodate
any
Dynamically
duty.
2008 Twin City Fan Companies, Ltd. All rights reserved throughout the world.
Bulletin illustrations cover the general appearance of Twin City Fan & Blower products at the time of publication
and we reserve the right to make changes in design and construction at any time without notice.
Propellers
WPD and WPB propeller fans are available with either
fixed pitch fabricated steel (sizes 21 through 60) or
adjustable pitch cast aluminum propellers(sizes 14
through 60). Each propeller type is designed for a wide
variety of commercial market applications with static
pressure capabilities from 0" to 1". Regardless of the
application requirement, WPD and WPB propellers offer
the right choice.
Propeller Availability
FAN SIZE
14
16
18
21
24
30
36
42
48
54
60
DIRECT DRIVE
E
E
E
E
E/Z
E/Z
E/Z
E/Z
E/Z
BELT DRIVEN
L1, L2, E
L1, L2, E/Z
L1, L2, E/Z
L1, L2, E/Z
L1, L2, E/Z
L1, L2, E/Z
L1, L2, C/Z
L1, L2, C/Z
Model Comparison
Twin City Fan offers a full line of propeller fans available in both direct drive and belt driven. Each model and
propeller type has been designed for a wide variety of commercial market applications. No matter what the
requirements are, Twin City Fan has the propeller fan to suit the application.
Direct Drive
LEVEL
PROPELLER
CONSTRUCTION
MODEL
SIZE
RANGE
PERFORMANCE
RANGE CFM
STATIC PRESSURE
CAPABILITY
PERFORMANCE
DATA LOCATION
Fabricated Aluminum
Blades Riveted to
Steel Hubs
TCPE
8-24
131 to 7,320
Up to 0.625 in w.g.
Bulletin 4800
14-48
883 to 35,350
Up to 1.00 in w.g.
Pages 9-10
24-48
3,100 to 32,200
12-48
686 to 39,980
Up to 1.50 in w.g.
Bulletins
AX500 &
AX510-A
Cast Aluminum
Blades and Hubs
WPD
TCWP
TCWPX
24-60
1,640 to 72,000
Belt Driven
LEVEL
PROPELLER
CONSTRUCTION
MODEL
SIZE
RANGE
PERFORMANCE
RANGE CFM
STATIC PRESSURE
CAPABILITY
PERFORMANCE
DATA LOCATION
WPB L1
21-60
2,970 to 35,100
Up to 0.375 in w.g.
Pages 11-18
Reinforced Galvanized
Steel Blades Riveted to
Galvanized Hubs
WPB L2
21-60
3,450 to 47,600
Up to 0.75 in w.g.
Pages 11-18
21-60
2,200 to 56,700
Cast Aluminum
Blades and Hubs
WPB L3
Cast Aluminum
Blades and Hubs
TCWP
Pages 11-18
Up to 1.00 in w.g.
24-60
3,300 to 62,800
24-48
3,600 to 38,000
Pages 12-18
Up to 1.50 in w.g.
TCWPX
24-72
4,000 to 75,000
Bulletins
AX500 &
AX510-A
Model Nomenclature
WPB - E - 24 - E4 - 16
Model
WPD = Wall Propeller Fan, Direct Drive
WPB = Wall Propeller Fan, Belt Driven
E = Exhaust, S = Supply
Fan Size
Propeller Type
L1 = Level 1, Fab. Steel
L2 = Level 2, Fab. Steel
E4 = Cast Alum., 4 Blade
E8 = Cast Alum., 8 Blade
EXHAUST FAN
in Wall Box with
Backdraft Damper & Weatherhood
FAN
SIZE
14
16
18
21
24
5
PRESS. DROP
CFM
(IN. W.G.)
EXHAUST SUPPLY
1000
0.04
0.06
1200
0.06
0.09
1400
0.09
0.12
1600
0.11
0.16
1800
0.14
0.20
2000
0.18
0.25
2200
0.22
0.30
2400
0.26
0.36
1600
0.07
0.10
1800
0.09
0.12
2000
0.11
0.15
2200
0.13
0.18
2400
0.15
0.21
2600
0.18
0.25
2800
0.21
0.29
3000
0.24
0.34
3500
0.32
0.46
2000
0.07
0.09
2200
0.08
0.11
2400
0.10
0.13
2600
0.11
0.16
2800
0.13
0.18
3000
0.15
0.21
3500
0.20
0.29
4000
0.27
0.37
4500
0.34
0.47
5000
0.41
0.58
2400
0.05
0.07
2600
0.06
0.09
2800
0.07
0.10
3000
0.08
0.11
3500
0.11
0.16
4000
0.15
0.20
4500
0.18
0.26
5000
0.23
0.32
5500
0.27
0.39
6000
0.33
0.46
6500
0.38
0.54
3500
0.07
0.09
4000
0.09
0.12
4500
0.11
0.15
5000
0.13
0.19
6000
0.19
0.27
7000
0.26
0.37
8000
0.34
0.48
9000
0.43
0.61
10000
0.53
0.75
FAN
SIZE
30
36
42
48
SUPPLY FAN
in Wall Box with
Backdraft Damper & Weatherhood
PRESS. DROP
CFM
(IN. W.G.)
EXHAUST SUPPLY
5000
0.05
0.08
6000
0.08
0.11
7000
0.11
0.15
8000
0.14
0.20
9000
0.18
0.25
10000
0.22
0.31
11000
0.26
0.37
12000
0.31
0.44
13000
0.37
0.52
14000
0.43
0.60
15000
0.49
0.69
7000
0.05
0.07
8000
0.07
0.09
9000
0.09
0.12
10000
0.11
0.15
11000
0.13
0.18
12000
0.15
0.21
13000
0.18
0.25
14000
0.21
0.29
16000
0.27
0.38
18000
0.34
0.48
20000
0.42
0.59
22000
0.51
0.72
10000
0.06
0.08
11000
0.07
0.10
12000
0.08
0.12
13000
0.10
0.14
14000
0.11
0.16
16000
0.15
0.21
18000
0.19
0.26
20000
0.23
0.32
22000
0.28
0.39
24000
0.33
0.46
26000
0.39
0.55
28000
0.45
0.63
14000
0.07
0.09
16000
0.09
0.12
18000
0.11
0.15
20000
0.13
0.19
22000
0.16
0.23
24000
0.19
0.27
26000
0.23
0.32
28000
0.26
0.37
30000
0.30
0.43
32000
0.35
0.49
34000
0.39
0.55
36000
0.44
0.62
FAN
SIZE
54
60
PRESS. DROP
CFM
(IN. W.G.)
EXHAUST SUPPLY
11000
0.03
0.04
12000
0.03
0.04
13000
0.04
0.05
14000
0.04
0.06
15000
0.05
0.07
16000
0.05
0.08
18000
0.07
0.10
20000
0.08
0.12
22000
0.10
0.14
24000
0.12
0.17
26000
0.14
0.20
28000
0.17
0.23
30000
0.19
0.27
32000
0.22
0.30
34000
0.24
0.34
36000
0.27
0.39
38000
0.30
0.43
40000
0.34
0.48
42000
0.37
0.52
44000
0.41
0.58
12000
0.02
0.03
13000
0.02
0.03
14000
0.03
0.04
15000
0.03
0.04
16000
0.04
0.05
18000
0.04
0.06
20000
0.06
0.08
22000
0.07
0.09
24000
0.08
0.11
26000
0.09
0.13
28000
0.11
0.15
30000
0.12
0.17
32000
0.14
0.20
34000
0.16
0.22
36000
0.18
0.25
38000
0.20
0.28
40000
0.22
0.31
42000
0.24
0.34
44000
0.27
0.38
46000
0.29
0.41
50000
0.34
0.49
52000
0.37
0.52
54000
0.40
0.57
56000
0.43
0.61
58000
0.46
0.65
Accessories
Wall Box with Guard
Backdraft Damper
Disconnect Switch
A NEMA 1, 3R or 7/9 safety disconnect switch is available for positive electrical shutoff of the fan and the
protection of service personnel. Disconnects are shipped
loose for field mounting and wiring.
Panel Fan
Wall Box
Backdraft Damper
NO
FFO
Weatherhood
Disconnect
Switch
Bird Screen
Damper Guard
Accessories
Wall Collar
The motor side guard meets OSHA standards by completely enclosing the motor and drive components.
Motor side guards are constructed of galvanized
steel side sheets and a removable wire mesh screen.
Prepunched mounting holes allow for easy installation to
the fan. (For use with or without a wall collar.)
Damper Guard
Weatherhood
A weatherhood is available to keep snow and rain from
entering the building and to prevent wind from altering the performance of the fan and backdraft damper.
The weatherhood is designed to fit over the backdraft
damper and can be installed to a wall collar via the
mounting flanges and prepunched mounting holes.
Weatherhoods are constructed of G90 galvanized steel
and are standard with a removable galvanized steel,
wire mesh, bird screen. Available fully assembled or as
a kit (field assembly required) to reduce shipping costs.
Weatherhoods are not weather tight when used with
supply fans.
OSHA Motor
Side Guard
Panel Fan
Wall Collar
Backdraft Damper
Weatherhood
NO
FFO
Disconnect
Switch
Bird Screen
Damper Guard
Mounting Arrangements
Flush with Outside Wall
MOUNTING FLANGE
MOUNTING FLANGE
BACKDRAFT DAMPER
WEATHERHOOD
WITH SCREEN
REMOVABLE
GUARD SCREEN
BACKDRAFT DAMPER
WEATHERHOOD
WITH SCREEN
REMOVABLE
GUARD SCREEN
AIR
FLOW
AIR
FLOW
FAN
FAN
SUPPORT
(BY OTHERS IF NEEDED)
SUPPORT
(BY OTHERS IF NEEDED)
Exhaust
Supply
Middle of Wall
MOUNTING FLANGE
MOUNTING FLANGE
BACKDRAFT DAMPER
WEATHERHOOD
WITH SCREEN
REMOVABLE
GUARD SCREEN
BACKDRAFT DAMPER
AIR
FLOW
AIR
FLOW
FAN
Exhaust
WEATHERHOOD
WITH SCREEN
REMOVABLE
GUARD SCREEN
FAN
SUPPORT
(BY OTHERS IF NEEDED)
SUPPORT
(BY OTHERS IF NEEDED)
Supply
MOUNTING FLANGE
BACKDRAFT DAMPER
BACKDRAFT DAMPER
WEATHERHOOD
WITH SCREEN
REMOVABLE
GUARD SCREEN
AIR
FLOW
AIR
FLOW
FAN
FAN
Exhaust
WEATHERHOOD
WITH SCREEN
REMOVABLE
GUARD SCREEN
SUPPORT
(BY OTHERS IF NEEDED)
SUPPORT
(BY OTHERS IF NEEDED)
Supply
SPACER
(BY OTHERS)
MIN
AIR
FLOW
BACKDRAFT
DAMPER
FAN
SIZE
14
16
18
21
24
30
36
42
48
54
60
MIN.
16
16
16
16
16
16
16
16
16
19
19
MOTOR FAN
BLADE
HP
RPM
ANGLE
Max RPM
20
1750
1
/4
24
1750
E4 Cast
28
1750
Aluminum
1
/3
1750
32
14
16
1750
1
E8 Cast
/4
20
1750
Aluminum
1
/3
1750
24
Max RPM
1
16
/4
1750
1
20
/3
1750
E4 Cast
1750
24
Aluminum
1
28
1750
/2
16
32
1750
1
16
/3
1750
E8 Cast
20
1750
1
/2
Aluminum
24
1750
Max RPM
1
16
/3
1750
1750
20
1
E4 Cast
/2
24
1750
Aluminum
1750
28
3
/4
18
32
1750
12
1750
1
E8 Cast
/2
16
1750
Aluminum
3
/4
1750
20
Max RPM
12
1750
1
/2
16
1750
3
/4
1750
20
E4 Cast
24
1750
Aluminum
1
28
1750
21
1750
32
11/2
3
12
/4
1750
E8 Cast
16
1
1750
1750
20
Aluminum
1 1/2
24
1750
Max RPM
1
12
/2
1750
3
/4
1750
16
E4 Cast
20
1
1750
1750
24
1 1/2
Aluminum
28
1750
2
32
1750
12
1
1750
E8 Cast
16
1 1/2
1750
20
1750
Aluminum
2
24
1750
24
1
30
/4
860
1
/3
860
35
40
860
1
/2
Z5
45
860
1
/2
1160
30
Fabricated
3
35
/4
1160
Steel
40
1
1160
1160
45
1 1/2
30
2
1750
SIZE
PROPELLER
MAX
BHP
E4 =
0.19
0.22
0.26
0.31
0.21
0.26
0.32
E4 =
0.23
0.29
0.37
0.45
0.52
0.34
0.43
0.54
E4 =
0.34
0.43
0.54
0.65
0.80
0.42
0.52
0.68
E4 =
0.40
0.53
0.71
0.89
1.10
1.34
0.68
0.87
1.16
1.45
E4 =
0.55
0.80
1.06
1.37
1.70
2.15
0.98
1.34
1.76
2.22
0.22
0.32
0.42
0.50
0.54
0.77
1.02
1.24
1.89
SONES
@ 0" SP 0.000
0.125
0.150
0.200
0.250
0.300
0.375
0.500
0.625
0.750
1.000
883
1113
1215
1256
1149
1388
1622
1178
1437
1604
1933
2186
2406
1787
2194
2551
1832
1591
1995
2348
2174
2687
3113
3522
3916
1982
2606
3196
2223
2689
3067
3447
1760
2410
3054
2404
3346
4245
4881
5528
6121
2999
3987
4926
5810
3740
4422
5047
5567
2720
3767
4739
5585
3750
4432
4932
2413
3478
4517
5326
3427
4966
6096
7212
8148
9175
4278
5747
7205
8450
4386
5565
6665
7624
8661
3928
5494
6948
8191
3661
4904
6043
7068
8119
3553
5181
6668
7920
6528
4951
5979
6410
7947
7680
7391
6544
1695
2091
2113
2510
2839
2134
2762
NOTES:
1. Performance certified is for installation type A: Free inlet, free outlet.
2. Performance ratings do not include the effects of appurtenances (accessories).
3. The sound ratings shown are loudness values in fan sone at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301.
Values are for installation Type A: Free inlet hemispherical sone levels.
4. The AMCA Certified Ratings Seal applies to sone ratings only.
3711
4615
4324
5930
7252
SIZE
30
36
42
MOTOR FAN
BLADE
HP
RPM
ANGLE
Max RPM
3
12
/4
1160
16
1
1160
E4 Cast
1160
20
11/2
Aluminum
24
1160
28
2
1160
12
1160
E8 Cast
11/2
16
1160
Aluminum
20
2
1160
1
30
/2
860
3
35
/4
860
Z5
40
860
1
45
860
Fabricated
30
1160
1
Steel
1 /2
35
1160
40
2
1160
Max RPM
12
1
1160
1160
16
11/2
E4 Cast
20
2
1160
Aluminum
24
1160
3
28
1160
12
2
1160
E8 Cast
16
1160
3
Aluminum
20
1160
30
860
1
1 /2
Z5
35
860
40
2
860
Fabricated
45
3
860
Steel
30
3
1160
Max RPM
12
11/2
860
16
2
860
E4 Cast
24
3
860
Aluminum
28
860
5
32
860
12
2
860
E8 Cast
16
3
860
20
860
Aluminum
5
24
860
3
860
Z5 Fabricated 30
PROPELLER
Steel
48
35
860
Max RPM
12
2
860
16
860
E4 Cast
3
20
860
Aluminum
24
860
5
28
860
12
3
860
E8 Cast
16
5
860
Aluminum
20
5
860
Z5 Fabricated
Steel
30
860
MAX
BHP
SONES
@ 0" SP 0.000
0.125
0.150
0.200
0.250
0.300
38
27263
25785
25480
25192
24657
24183
0.375
Size = 184T
5683
5197
7283
6843
8872
8439
10268
9817
11744 11287
6239
5966
7950
7706
9713
9467
5477
6996
5996
8246
7243
9071
8089
8932
8552
10950 10568
12863 12375
Size = 215T
7817
7177
10341
9752
13286 12678
15644 15035
18069 17460
8762
8422
11855 11519
14849 14535
10927 10170
13511 12813
15819 14960
17258 16369
16195 15759
Size = 254T
10826
9873
14008 13149
20111 19229
23079 22184
25391 24461
11983 11458
15503 15021
19074 18597
22396 21946
20112 19515
23773
23203
Size = 254T
13637 12468
18080 17009
23252 22149
27396 26291
31657 30550
15343 14728
20780 20168
26044 25476
4.83
28386
47
32263
30838
30504
30178
29548
28944
27605
0.500
5965
7629
9007
10437
5430
7242
9069
0.625
0.750
6565
8029
9409
6540
8064
6696
8627
7961
7752
9818
11479
6515
8653
10428
8613
11562
13948
16335
7719
10847
13977
8241
11002
13273
14788
15033
7205
10278
12819
15184
8753
11431
13870
10113
13367
9341
12666
14169
13121
17656
20539
22750
10403
14097
17804
21132
18229
15814
18632
20684
13085
16081
18163
13034
16931
20214
16809
15701
19115
15127
22221
20821
18852
14925
20122
24331
28516
12354
17773
22278
26440
14943
19685
23972
18942
24467
17620
23356
16204
22064
26290
24703
22762
1.000
7222
10750
12575
15785
NOTES:
1. Performance certified is for installation type A: Free inlet, free outlet.
2. Performance ratings do not include the effects of appurtenances (accessories).
3. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301.
Values are for installation Type A: Free inlet hemispherical sone levels.
4. The AMCA Certified Ratings Seal applies to sone ratings only.
10
/4
761
785
L1
812
1
/3
837
Fabricated
864
Steel
914
1
/2
959
989
Level 2 Performance Max RPM
914
1
/2
959
L2
989
Fabricated
1046
3
Steel
/4
1097
1133
Level 3 Performance Max RPM
20
1309
1
/4
28
1116
32
1043
1440
20
1
/3
28
1228
32
1147
E4 Cast
1650
20
1
Aluminum
28
1407
/2
32
1314
1888
20
3
28
/4
1610
32
1504
1
32
/4
886
1
E8 Cast
32
/3
975
1
/2
1116
32
Aluminum
3
32
/4
1278
PROPELLER
MAX
BHP
SONES
@ 0" SP
0.100
0.125
0.150
0.200
0.250
0.300
0.375
0.500
0.625
0.750
3559
3611
3447
4515
4815
4764
4165
4278
4138
3693
3551
3466
4695
4121
1.000
NOTES:
1. Performance certified is for installation type A: Free inlet, free outlet.
2. Power rating (BHP) does not include transmission losses.
3. Performance ratings do not include the effects of appurtenances (accessories).
4. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301.
Values are for installation Type A: Free inlet hemispherical sone levels.
5. The AMCA Certified Ratings Seal applies to sone ratings only.
11
/4
609
0.25
10.3
5237
4508
4183
3843
629
0.28
10.6
5409
4729
4427
4108
651
0.30
11.4
5599
4961
4694
4384
3650
1
/3
671
0.33
12.2
5771
5166
4928
4629
3963
L1
692
0.37
12.9
5951
5375
5164
4886
4281
Fabricated
732
0.43
13.9
6295
5765
5590
5363
4816
4150
1
Steel
/2
768
0.50
15.2
6605
6109
5953
5766
5263
4703
809
0.59
16.3
6957
6495
6354
6197
5763
5264
4658
838
0.65
17.1
7207
6765
6633
6489
6109
5630
5102
3
/4
879
0.75
18.5
7559
7143
7022
6891
6573
6132
5672
907
0.83
19.5
7800
7400
7285
7161
6874
6474
6030
Level 2 Performance Max RPM L2 = 986 Max Motor Frame Size = 145T
732
0.43
13.9
6295
5765
5590
5363
4816
4150
1
/2
768
0.50
15.2
6605
6109
5953
5766
5263
4703
809
0.59
16.3
6957
6495
6354
6197
5763
5264
4658
L2
838
0.65
17.1
7207
6765
6633
6489
6109
5630
5102
3
/4
879
0.75
18.5
7559
7143
7022
6891
6573
6132
5672
Fabricated
907
0.83
19.5
7800
7400
7285
7161
6874
6474
6030
5247
Steel
938
0.91
20
8067
7682
7573
7457
7195
6843
6413
5721
1
967
1.00
22
8316
7945
7841
7731
7486
7174
6767
6132
986
1.06
22
8480
8117
8016
7909
7674
7384
7000
6384
Level 3 Performance Max RPM E4 = 1930 E8 = 1175 Z5 = 1450 Max Motor Frame Size = 145T
16
1336
0.37
25
4987
4596
4493
4390
4177
3947
3690
3232
1
24
/3
1110
0.37
20
5644
5103
4970
4841
4571
4254
3890
3221
32
964
0.37
16.5
5904
5276
5110
4940
4571
4150
3683
1531
0.55
32
5715
5376
5289
5200
5019
4835
4640
4317
16
1
24
/2
1272
0.55
25
6468
5996
5878
5761
5533
5300
5039
4583
E4 Cast
32
1104
0.55
21
6761
6219
6077
5933
5638
5319
4966
4383
1752
0.82
43
6540
6246
6171
6094
5940
5782
5622
5372
16
Aluminum
3
/4
24
1456
0.82
32
7404
6991
6888
6785
6580
6381
6181
5855
32
1263
0.82
26
7735
7265
7143
7020
6769
6512
6241
5794
16
1929
1.10
52
7201
6935
6867
6798
6659
6518
6375
6157
24
1
1602
1.10
39
8146
7771
7677
7583
7396
7211
7031
6757
32
1391
1.10
30
8518
8094
7985
7875
7650
7421
7187
6816
1
32
/3
813
0.37
14.0
5545
5107
4984
4855
4571
4203
3688
1
E8 Cast
/2
931
0.55
17.0
6350
5975
5874
5768
5545
5300
5012
4399
32
3
32
/4
1066
0.82
21
7271
6949
6863
6775
6592
6398
6191
5839
Aluminum
32
1
1173
1.10
24
8001
7710
7634
7556
7395
7227
7050
6766
30
1004
0.37
18.9
5239
4811
4708
4610
4423
4219
3952
3326
1
/3
45
766
0.37
14.7
5851
5210
5048
4879
4384
1150
0.55
23
6001
5624
5533
5443
5270
5107
4937
4622
30
1
Z5
/2
45
878
0.55
18.5
6707
6154
6009
5867
5574
5177
4482
Fabricated
1316
0.82
28
6867
6536
6455
6375
6217
6065
5922
5705
30
3
/4
Steel
45
1005
0.82
23
7677
7198
7074
6948
6698
6446
6149
5366
30
1448
1.10
32
7556
7254
7180
7107
6962
6818
6681
6485
1
45
1106
1.10
27
8449
8015
7904
7791
7562
7336
7107
6689
PROPELLER
0.500
0.625
0.750
1.000
3657
4905
5196
4946
5770
6237
6115
4341
4388
3582
5330
5614
5311
4815
4873
4968
6185
5318
3721
5250
4531
6146
5696
5035
NOTES:
1. Performance certified is for installation type A: Free inlet, free outlet.
2. Power rating (BHP) does not include transmission losses.
3. Performance ratings do not include the effects of appurtenances (accessories).
4. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301.
Values are for installation Type A: Free inlet hemispherical sone levels.
5. The AMCA Certified Ratings Seal applies to sone ratings only.
12
420
433
448
1
/3
462
477
L1
504
1
/2
529
Fabricated
546
Steel
577
3
/4
605
625
646
1
666
696
Level 2 Performance Max RPM
577
3
/4
605
625
646
1
666
L2
696
Fabricated
727
Steel
762
11/2
787
814
2
839
866
Level 3 Performance Max RPM
16
984
1
24
827
/2
32
716
1126
16
3
24
946
/4
32
820
16
1239
24
1
1041
E4 Cast
32
902
1418
16
Aluminum
1
24
1191
1 /2
32
1033
16
1561
24
2
1311
32
1137
24
1502
28
3
1393
32
1302
1
32
/2
614
3
32
/4
703
E8 Cast
32
1
774
Aluminum
1
886
32
1 /2
32
2
975
35
815
1
/2
45
682
933
35
3
/4
45
781
Z5
35
1027
1
45
859
Fabricated
1174
35
1
Steel
1 /2
45
984
35
1294
2
45
1082
45
3
1240
PROPELLER
MAX
BHP
SONES
@ 0" SP
0.100
0.125
0.150
0.200
0.250
0.300
0.375
0.500
0.625
0.750
1.000
Size = 145T
7242
7840
8677
Size = 184T
7242
7840
8677
9457
8239
10297
9268
10895
9929
11529
10602
12095
11205
12681
11849
Size = 184T
5475
4789
5752
5070
6853
6385
7450
6765
7368
6148
7868
7477
8636
8110
8736
7972
9401
9083
10382
9979
10756
10157
10586
10306
11731
11373
12266
11758
13827
13518
14270
13921
14553
14149
5383
7336
6354
8688
7952
10525
10077
11855
11527
6038
7804
7464
9067
9005
10909
11125
12334
12670
15076
8666
9500
10307
5392
6739
6981
5751
8515
9217
9047
9818
10750
10834
12998
13308
13413
7879
8259
7307
9290
10025
9771
12458
12650
12610
8710
9149
8136
11861
11943
11747
6569
9014
10772
7765
9727
8596
7114
6908
7186
10374
10089
9125
7107
8500
7359
10471
10485
11971
12144
14633
9647
8676
11287
11138
13869
10521
9637
13000
11927
NOTES:
1. Performance certified is for installation type A: Free inlet, free outlet.
2. Power rating (BHP) does not include transmission losses.
3. Performance ratings do not include the effects of appurtenances (accessories).
4. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301.
Values are for installation Type A: Free inlet hemispherical sone levels.
5. The AMCA Certified Ratings Seal applies to sone ratings only.
13
/3
358
369
390
1
/2
410
L1
423
Fabricated
447
3
Steel
/4
469
484
500
1
516
533
Level 2 Performance Max RPM
500
1
516
533
L2
563
11/2
591
Fabricated
610
Steel
631
2
650
671
Level 3 Performance Max RPM
20
877
3
/4
28
738
32
686
20
966
28
1
812
32
755
1105
20
1
28
930
1 /2
E4 Cast
32
865
Aluminum
20
1217
28
2
1023
32
952
20
1392
28
3
1171
32
1089
PROPELLER
28
32
E8 Cast
Aluminum
Z5
Fabricated
Steel
32
32
32
32
32
35
45
35
45
35
45
35
45
35
45
45
5
/4
1
1
1 /2
2
3
3
/4
1
11/2
2
3
5
MAX
BHP
SONES
@ 0" SP
0.100
0.125
0.150
0.200
0.250
0.300
0.375
0.500
0.625
8609
9684
10465
11237
8890
0.750
10325
10879
10134
12282
13245
12946
15060
16574
16616
11201
11673
10754
14251
15439
15183
13345
14203
13454
20311
19344
11072
15061
13665
1391
5.47
59
24195
23664
23527
23389
23108
22819
22523
22062
21235
1292
5.47
53
24728
24113
23955
23796
23473
23142
22805
22283
21368
575
633
724
797
913
688
576
757
634
868
726
954
799
1092
915
1084
0.83
1.10
1.65
2.20
3.30
0.82
0.82
1.09
1.10
1.64
1.65
2.19
2.19
3.26
3.30
5.49
19.7
24
30
34
40
20
16.6
23
19.1
29
24
34
28
43
34
47
12118
13340
15258
16797
19241
12471
13473
13722
14829
15734
16981
17293
18689
19795
21402
25355
11223
12540
14569
16176
18705
11558
11997
12905
13499
15034
15829
16662
17647
19248
20497
24595
10974
12321
14386
16013
18565
11301
11615
12681
13152
14847
15531
16495
17379
19106
20266
24402
10711
12095
14197
15846
18424
11028
11221
12448
12805
14654
15229
16325
17108
18962
20033
24208
10137
11610
13803
15501
18134
10416
10325
11940
12072
14250
14622
15971
16558
18665
19561
23817
9453
11073
13382
15138
17833
9730
8555
10448
12928
14754
17521
8948
9202
12155
14132
17029
10357
12876
16128
11367
11228
13811
13990
15597
16006
18357
19080
23420
10741
9653
13329
13279
15197
15430
18036
18600
23018
12533
11944
14533
14457
17525
17861
22409
1.000
8946
9944
9271
11189
10966
13288
11760
16565
16458
21384
15487
14265
20257
18990
NOTES:
1. Performance certified is for installation type A: Free inlet, free outlet.
2. Power rating (BHP) does not include transmission losses.
3. Performance ratings do not include the effects of appurtenances (accessories).
4. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301.
Values are for installation Type A: Free inlet hemispherical sone levels.
5. The AMCA Certified Ratings Seal applies to sone ratings only.
14
/3
276
285
302
1
/2
316
L1
327
Fabricated
345
3
Steel
/4
362
374
387
1
399
411
Level 2 Performance Max RPM
387
1
399
411
435
1
456
1 /2
471
L2
487
2
502
Fabricated
518
Steel
548
3
575
593
640
5
681
703
Level 3 Performance Max RPM
20
669
28
1
568
32
530
20
768
651
28
11/2
32
608
E4 Cast
20
841
Aluminum
28
2
718
32
668
20
964
28
3
820
32
767
32
5
909
32
1
453
E8 Cast
520
32
11/2
32
2
572
Aluminum
32
3
655
30
603
1
45
467
690
30
11/2
45
534
Z5
30
760
2
Fabricated
45
588
Steel
30
870
3
45
673
40
850
5
45
798
PROPELLER
MAX
BHP
SONES
@ 0" SP
0.100
0.125
0.150
0.200
0.250
0.300
0.375
0.500
0.625
0.750
11225
13664
15286
16285
18909
21433
22801
12083
13858
16928
19193
20417
14316
17362
18653
1.000
10810
13776
13676
12150
17594
18442
18128
24373
16199
16266
14979
22660
13237
18112
15681
14294
20658
11851
14805
18560
17035
25124
24746
16713
15708
22702
21016
21254
NOTES:
1. Performance certified is for installation type A: Free inlet, free outlet.
2. Power rating (BHP) does not include transmission losses.
3. Performance ratings do not include the effects of appurtenances (accessories).
4. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301.
Values are for installation Type A: Free inlet hemispherical sone levels.
5. The AMCA Certified Ratings Seal applies to sone ratings only.
15
/2
254
262
L1
277
Fabricated
3
/4
291
Steel
300
310
1
320
330
Level 2 Performance Max RPM
310
1
320
330
349
1
1 /2
366
378
L2
391
2
403
Fabricated
416
Steel
440
3
461
476
514
5
547
564
Level 3 Performance Max RPM
20
685
28
11/2
575
32
535
20
753
28
2
633
32
589
E4 Cast
20
862
28
3
725
Aluminum
32
674
20
1022
28
5
860
32
800
985
28
71/2
32
916
1
32
1 /2
448
E8 Cast
32
2
494
32
3
565
Aluminum
32
5
670
35
537
11/2
45
449
35
591
2
Z5
45
495
35
677
Fabricated
3
45
567
Steel
35
802
5
45
671
1
45
7 /2
769
PROPELLER
MAX
BHP
SONES
@ 0" SP
0.100
0.125
0.150
0.200
0.250
0.300
0.375
0.500
0.625
0.750
15790
17499
20870
23584
25051
17462
20979
22448
19257
1.000
14830
14140
19773
21106
20091
25976
28509
28543
34904
35140
17572
17488
24473
26447
25851
33103
33194
22783
24072
22536
31305
30975
20331
27751
25716
23008
26535
24205
32840
29917
27257
25350
21247
28529
28117
35101
NOTES:
1. Performance certified is for installation type A: Free inlet, free outlet.
2. Power rating (BHP) does not include transmission losses.
3. Performance ratings do not include the effects of appurtenances (accessories).
4. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301.
Values are for installation Type A: Free inlet hemispherical sone levels.
5. The AMCA Certified Ratings Seal applies to sone ratings only.
16
3/4
240
248
L1
256
1
264
Fabricated
273
Steel
289
303
11/2
312
Level 2 Performance Max RPM
289
11/2
303
312
323
2
333
L2
344
Fabricated
364
Steel
3
381
394
425
5
452
467
Level 3 Performance Max RPM
10
660
11/2
20
530
10
725
2
20
582
10
830
C3 Cast
3
20
667
Aluminum
10
985
5
20
791
908
20
71/2
25
854
25
10
940
10
531
20
11/2
436
25
403
10
585
20
2
480
25
443
10
669
C6 Cast
20
3
550
Aluminum
25
508
10
794
20
5
652
25
602
749
20
71/2
25
691
20
10
761
30
444
11/2
45
341
30
489
2
45
376
Z5
30
560
3
45
430
Fabricated
30
663
Steel
5
45
510
622
40
71/2
45
584
45
10
643
PROPELLER
MAX
BHP
SONES
@ 0" SP
0.100
0.125
0.150
0.200
0.250
0.300
0.375
0.500
0.625
22416
25838
27592
21092
23857
0.750
1.000
17658
26128
26073
34338
32920
39085
22950
20366
31021
28580
35683
19821
26557
22600
31709
13369
19649
19710
16345
27041
28835
28062
36278
35355
37164
24642
25678
23554
33832
32947
34771
31198
29620
32225
28684
25812
36186
33296
41823
31966
22560
22866
30849
27629
39360
38496
44931
37003
NOTES:
1. Performance certified is for installation type A: Free inlet, free outlet.
2. Power rating (BHP) does not include transmission losses.
3. Performance ratings do not include the effects of appurtenances (accessories).
4. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301.
Values are for installation Type A: Free inlet hemispherical sone levels.
5. The AMCA Certified Ratings Seal applies to sone ratings only.
17
/4
200
207
214
1
220
L1
228
Fabricated
241
Steel
252
11/2
261
269
2
278
287
Level 2 Performance Max RPM
241
11/2
252
261
269
2
278
L2
287
Fabricated
303
Steel
3
318
328
354
5
377
389
Level 3 Performance Max RPM
10
678
20
2
534
25
489
10
777
20
3
610
25
560
C3 Cast
10
920
20
5
724
Aluminum
25
664
955
10
1
20
828
7 /2
25
760
20
912
10
25
839
10
547
20
2
438
25
400
10
626
20
3
501
25
458
10
742
C6 Cast
20
5
594
Aluminum
25
543
849
10
1
20
680
7 /2
25
621
15
833
20
10
752
25
687
30
395
11/2
45
302
30
435
2
45
333
30
498
3
Z5
45
381
30
591
Fabricated
5
45
452
Steel
554
40
71/2
45
517
35
673
40
10
608
45
569
PROPELLER
MAX
BHP
SONES
@ 0" SP
0.100
0.125
0.150
0.200
0.250
0.300
0.375
0.500
0.625
0.750
1.000
27486
26591
23625
19738
29712
36750
25734
31767
22544
43921
39446
12819
39844
35318
20515
15979
29154
29840
28906
35976
38810
38056
43319
45436
44957
26443
25958
22965
33854
34978
34138
41106
42561
41770
31667
31752
25817
38587
39054
38245
33676
32917
44629
43043
37471
26570
28891
18205
22958
33668
30341
44030
42214
50097
50961
50172
39113
47506
47634
45645
NOTES:
1. Performance certified is for installation type A: Free inlet, free outlet.
2. Power rating (BHP) does not include transmission losses.
3. Performance ratings do not include the effects of appurtenances (accessories).
4. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA Standard 301.
Values are for installation Type A: Free inlet hemispherical sone levels.
5. The AMCA Certified Ratings Seal applies to sone ratings only.
18
Dimensional Data
Direct Drive - WPD
C SQ. OUTSIDE
D MAX
2.00
D MAX
AIR
FLOW
A DIA.
AIR
FLOW
A DIA.
2.00
C SQ.
14
16
18
21
24
30
36
42
48
14.25
16.25
18.25
21.25
24.25
30.38
36.38
42.38
48.38
2.75
3.00
3.00
3.50
3.50
4.00
5.00
5.50
6.00
17
20
22
25
28
36
42
48
54
MAX
DAMPER
EXHAUST
SUPPLY
11.18
11.18
11.18
14.41
14.55
14.74
15.67
23.59
23.59
14.88
14.88
14.88
17.36
17.36
19.05
19.93
30.00
30.00
MOTOR
SIZE
14
17
19
22
25
33
39
45
51
x
x
x
x
x
x
x
x
x
FRAME
56
56
56
145T
184T
184T
215T
254T
254T
14
17
19
22
25
33
39
45
51
D MAX
2.00
D MAX
AIR
FLOW
A DIA.
AIR
FLOW
A DIA.
2.00
19
A
21.25
24.25
30.38
36.38
42.38
48.38
54.38
60.38
B
3.50
3.50
4.00
5.00
5.50
6.00
6.50
7.25
C SQ.
25
28
36
42
48
54
60
66
EXHAUST
L1
15.88
16.19
17.81
17.50
17.88
18.75
18.88
19.50
L2
15.88
16.19
19.31
19.13
19.38
20.13
20.50
24.75
SUPPLY
L1
18.44
19.19
20.50
21.50
22.19
23.06
23.69
24.44
L2
18.44
19.19
22.00
23.13
23.75
24.63
25.19
29.94
DAMPER
SIZE
22
25
33
39
45
51
57
63
x
x
x
x
x
x
x
x
22
25
33
39
45
51
57
63
MAX MOTOR
FRAME
L1
L2
56
56
145T
145T
145T
145T
145T
145T
145T
145T
184T
184T
184T
184T
184T
215T
Dimensional Data
Belt Driven - WPB, Level 3, Sizes 21-36
C SQ. OUTSIDE
D MAX
AIR
FLOW
2.00
D MAX
A DIA.
AIR
FLOW
A DIA.
2.00
D MAX
SIZE
C SQ.
21
24
30
36
21.25
24.25
30.38
36.38
3.50
3.50
4.00
5.00
25
28
36
42
MAX
DAMPER
EXHAUST
SUPPLY
17.25
17.25
18.31
18.31
20.50
20.50
20.93
21.93
MOTOR
SIZE
22
25
33
39
x
x
x
x
FRAME
145T
145T
184T
184T
22
25
33
39
D MAX
AIR
FLOW
D MAX
A DIA.
2.00
2.00
AIR
FLOW
A DIA.
20
SIZE
C SQ.
42
48
54
60
42.38
48.38
54.38
60.38
5.50
6.00
6.50
7.25
48
54
60
66
DAMPER
EXHAUST
SUPPLY
21.31
21.31
26.13
26.13
26.75
26.75
32.30
32.30
SIZE
45
51
57
63
x
x
x
x
45
51
57
63
MAX
MOTOR
FRAME
215T
215T
254T
256T
MINIMUM
SIZE
A SQ.
(INSIDE)
16 GA.
C
SQ.
Wall Collar
16 GA.
Backdraft Damper
B SQ.
I.D.
6.25"
REF
AIRFLOW
31/2"
TYP
SIZE
14
16
18
21
24
30
36
42
48
54
60
C REF.
3
/4" Reg. & 5/8"
Ext. TYP
3
5
14.63
17.63
19.63
22.63
25.63
33.63
39.63
45.63
51.63
57.63
63.63
SIZE
A SQ.
C SQ.
WALL
20.00
20.00
20.00
21.00
22.00
23.00
23.00
24.00
25.00
26.00
26.00
14.63
17.63
19.63
22.63
25.63
33.63
39.63
45.63
51.63
57.63
63.63
OPENING
18
21
23
26
29
37
43
49
55
61
67
B SQ.
14
17
19
22
25
33
39
45
51
57
63
3.50
3.50
3.50
3.50
3.50
3.50
5.50
5.50
5.00
5.00
5.00
17.25
20.25
22.25
25.25
28.25
36.25
42.25
48.25
54.25
60.25
66.25
A SQ.
FLANGE
17.00
20.00
22.00
25.00
28.00
36.00
42.00
48.00
54.00
60.00
66.00
NO. OF
PANELS
1
1
1
1
1
1
2
2
2
2
2
5
/8"
TYP
A SQ.
O.D.
B SQ.
I.D.
33.50
34.00
34.00
36.00
37.00
40.00
40.00
43.00
43.00
49.00
50.00
14
16
18
21
24
30
36
42
48
54
60
3"
C
OPEN
POSITION
31/2"
TYP
WALL
OPENING
18
21
23
26
29
37
43
49
55
61
67
17.25
20.25
22.25
25.25
28.25
36.25
42.25
48.25
54.25
60.25
66.25
SIZE
S
5
/8"
TYP
C SQ.
14
16
18
21
24
30
36
42
48
54
60
14
16
18
21
24
30
36
42
48
54
60
A SQ.
MINIMUM
A SQ.
I.D.
C SQ.
A SQ.
A SQ.
REG.
EXT.
17.25
21.25
20.25
24.25
22.25
26.25
25.25
29.25
28.25
32.25
36.25
40.25
42.25
46.25
48.25
52.25
54.25
58.25
60.25
64.25
66.25
70.25
B SQ.
REG.
EXT.
14.63
14.75
17.63
17.75
19.63
19.75
22.63
22.75
25.63
25.75
33.63
33.75
39.63
39.75
45.63
45.75
51.63
51.75
57.63
57.75
63.63
63.75
GA.
15.06
17.13
19.50
22.09
25.13
33.25
39.25
45.25
51.25
56.00
61.25
18
18
18
18
18
16
16
16
16
16
16
30
21
18 GA.
C
SQ.
A SQ.
SIZE
A SQ.
B SQ.
C SQ.
14
16
18
21
24
30
36
42
48
54
60
15
18
20
23
26
34
40
46
52
58
64
15.75
18.75
20.75
23.75
26.75
34.75
40.75
46.75
52.75
58.75
64.75
17
20
22
25
28
36
42
48
54
60
66
SIZE
A SQ.
14
16
18
21
24
30
36
42
48
54
60
16.88
19.88
21.88
24.88
27.88
35.19
41.19
47.19
53.19
59.19
65.19
15.25
15.50
15.50
20.50
23.50
23.50
25.50
29.50
30.25
27.75
32.00
C3
345
423
C6
369
438
8"
18 GA.
A SQ.
OUTSIDE
Engineering Data
Approx. Shipping Weight (LB.)
FAN SIZE
WPD
E8
45
49
52
69
77
105
154
210
224
E4
41
47
50
58
74
99
127
195
208
14
16
18
21
24
30
36
42
48
54
60
Z5
78
111
175
229
247
L1
61
69
90
115
147
160
184
261
L2
69
74
100
127
167
248
276
368
WPB
E8
75
86
118
146
212
289
E4
72
80
103
139
197
273
Z5
90
124
161
267
324
440
470
Material Specification
FAN
SIZE
14
16
18
21
24
30
36
42
48
54
60
22
WPD
18
18
18
18
16
16
16
14
14
FAN PANEL
WPB
L1/L2
E/C/Z
18
18
18
18
16
16
16
14
18
16
16
16
14
14
14
14
GAUGE OF MATERIAL
DRIVE FRAME
PROPELLERS
WPB
WPD
L1/L2
E
C
L1/L2
E/C/Z
14
14
14
14
12
12
12
10
10
14
14
12
12
12
12
12
12
14
14
12
12
12
12
10
10
16
16
16
16
14
14
14
12
DIE
CAST
ALUM.
CAST
ALUM.
HUBS
Z
L1/L2
L1
L2
E/C/Z
14
14
12
10
10
10
10
14
14
14
14
12
12
12
3
/16
12
12
12
10
10
7
7
3
/4
3
/4
3
/4
3
/4
1
1
1
13/16
3
/4
3
/4
1
1
13/16
13/16
13/16
11/2
1
1
1
1
13/16
17/16
17/16
111/16
23