Anda di halaman 1dari 2

Product Data Submittal

Fulton FB-S Horizontal


Fuel-Fired Steam Boilers

Fulton Models: FB-S 60, 100, 150,


200, 250, 300, 400

Dimensions
Models

FB-S

60

100

150

200

250

300

400

BHP
IN
MM
IN
MM
IN
MM
IN
MM
IN
MM

60
131
3,327
173
4,394
67
1,702
77
1,956
32
813

100
143
3,632
185
4,699
70
1,788
80
2,032
34
837

150
161
4,089
207
5,258
83
2,108
92
2,337
36
914

200
188
4,775
234
5,944
86
2,184
98
2,489
36
914

250
195
4,953
246
6,248
86
2,184
100
2,540
43
1,092

300
236
5,994
286
7,264
86
2,184
100
2,540
43
1,092

400
218
5,537
270
6,858
106
2,692
118
2,997
46
1,168

LB
KG
LB
KG
GAL
LITERS

9,460
4,291
14,972
6,791
661
2,500

11,330
5,139
17,827
8,086
779
2,950

14,300
6,486
22,006
9,982
924
3,500

20,240
9,181
31,032
14,076
1,294
4,900

25,564
11,596
38,783
17,592
1,585
6,000

28,786
13,057
44,207
20,052
1,849
6,998

38,126
17,294
56,407
25,586
2,192
8,297

A. Boiler Length (w/o burner)


B. Boiler Length (w/ burner)
C. Boiler Width (w/ trim)
D. Boiler Height (w/ trim)
E. Door Opening

Approximate Weights
Shipping Weight
Operating Weight
Water Content

Specifications and Dimensions are approximate. We reserve the right to change specifications and/or dimensions without notice.

C
E

A
B

Specifications
Models
Max Operating Pressure *
Steam Output

FB-S

60

100

150

200

250

300

400

BHP
PSI
BAR
LBS/HR
KG/HR

60
150
10.3
2,204
1,000

100
150
10.3
3,306
1,500

150
150
10.3
4,409
2,000

200
150
10.3
6,612
2,999

250
150
10.3
8,816
3,999

300
150
10.3
9,918
4,499

400
150
10.3
13,224
5,998

GPH
LPH
FT3/HR
M3/HR

19
72
2,705
77

28
106
4,058
115

37
140
5,378
153

56
212
8,122
230

75
284
10,806
306

84
318
11,936
338

112
424
15,715
445

IN
MM
IN
MM
IN
MM
IN
MM
IN
MM
IN
MM

2
51
2
51
1.25
32
1.5
38
0.5
13
12
305

2
51
2.5
64
1.25
32
1.5
38
0.5
13
14
356

2
51
3
76
1.25
32
1.5
38
0.5
13
16
381

2
51
4
102
1.25
32
2
51
0.5
13
18
457

2
51
4
102
1.5
38
2
51
0.5
13
20
508

2.5
64
4
102
1.5
38
1.5
38
0.5
13
20
508

3
76
5
127
2
51
2
51
0.5
13
24
610

BHP
KW
BHP
KW

2
1.5
2
1.5

3
2.2
3
2.2

7.5
4.5
7.5
4.5

15
7.5
15
7.5

15
7.5
20
15

15
7.5
20
15

20
15
20
15

Approximate Fuel Usage


Light Oil **
Natural Gas **

Connections
Safety Relief Valve
Steam Outlet (150 lb flange)
Feedwater inlet
Blowdown
Water Column Blowdown
Stack Diameter

Power
Burner Motor (Oil)
Burner Motor (Gas)
* Please consult factory for alternate operating pressures.
** Please consult factory for additional fuel options.
Specifications and Dimensions are approximate. Consult factory for model specific electrical requirements.
We reserve the right to change specifications and/or dimensions without notice.

Fulton Boiler Works, Inc.


3981 Port Street, Box 257
Pulaski, New York USA 13142
Call: 315-298.5121
Fax: 315-298.6390
www.fulton.com

FB-S PDS
080907
Printed in USA

Anda mungkin juga menyukai