Thermodynamic model of HPeIP leakage and IP turbine efciency

Jian-qun Xu
a
, Gang Li
a
, Ling Li
a,
*
, Ke-yi Zhou
a
, Yong-feng Shi
b
a
School of Energy and Environment, Southeast University, Nanjing 210096, China
b
Huadian Electric Power Research Institute, Hangzhou 310030, China
a r t i c l e i n f o
Article history:
Received 25 June 2010
Accepted 14 September 2010
Available online 19 September 2010
Keywords:
Steam turbine
Steam leakage
Temperature variation method
Numerical calculation method
Error analysis
IP turbine efciency
a b s t r a c t
In this paper, temperature variation method and numerical calculation method are both presented for
the calculation of the HPeIP steam leakage through midspan packing (N2 packing), which is called N2
leakage for short, and an error analysis mathematical model about the impact of measured parameters
error on N2 leakage rate is established. The two methods have been both applied to a 600 MW super-
critical steam turbines N2 leakage rate estimation, and the results show that numerical calculation
method can estimate N2 leakage rate as accurately as temperature variation method, and the chief
parameters which affect the accuracy of N2 leakage rate are hot reheat temperature and IP turbine
exhaust temperature. Taking the leakage from HP turbine exhaust balance piston to IP turbine exhaust
zone (N1 leakage) quantity into account, which has great inuence on N2 leakage calculation precision,
combined with N2 leakage, IP turbine efciency is calculated exactly, and the result indicates that:
Compared to N1 leakage, N2 leakage is the main factor which affects the IP efciency.
2010 Elsevier Ltd. All rights reserved.
1. Introduction
Steam turbine thermal performance parameters are the
important indexes to evaluate operation states and equipment
performance, among these parameters, turbine efciency shows
the degree of turbine ow path aerodynamics perfection, and heat
rate expresses the steam turbines capacity of converting heat to
work. To obtain these parameters accurately is important for steam
turbine operation optimization, energy saving and technological
innovation. Generally, combined HPeIP casing steam turbine has
HPeIP leakage (N2 leakage in this paper) [1], which inuences the
accuracy of efciency and other performances, and the denition
can be seen in Fig. 1. For impulse steam turbine, N2 leakage mixes
with the main steamow behind IP turbine rst-stage; for reaction
steam turbine, which has no impeller and balance hole, N2 leakage
mixes with the main steam ow behind the stationary blades of IP
turbine rst-stage.
N2 leakage causes loss, because it cannot produce work in HP
turbine and stationary blades of IP turbine rst-stage [2]. Mean-
while, without being reheated, the leakage will also reduce the cycle
efciency. If N2 leakage is ignored in the thermal calculation, IP
turbine efciency and heat rate of the unit will be greater than the
actual value, i.e. the leakage reduces the economy of the steam
turbine unit. As the application of steam seals is the most popular
means usedinthesteamturbinetoreducetheleakage, thereis much
researchon its behavior, aiming to increase its durability and reduce
the leakage. Tong Seop Kim and Kyu Sang Cha [3] analyzed the
inuence of conguration and clearance on the leakage behavior of
labyrinth seals. Jun Li, et al. [4] used the three-dimensional
Reynolds-averaged NaviereStokes (RANS) solutions from CFX to
investigate the leakage ow characteristics in the labyrinth honey-
comb seal of steam turbines. Luis San Andres, et al. [5] proved that
the hybrid brush seal (HBS) was more durable and reliable than
conventional brush seals, and allows reverse shaft rotation without
seal damage, and the result indicated that ow rate measurements
at room temperature 25

C had a leakage reduction of about 36%
compared with a rst generation shoed-brush seal.
There are also some calculation methods, when N2 internal
packing is intact and the installation gap is under the limited level,
Martins formula can be applied to N2 leakage rate estimation, and
the result is almost equal to the actual leakage quantity, meeting
the requirements of engineering calculations. However, the seal
teeth are easy to wear as the result of rotor deection and vibration.
In this condition, Martins formula does not work well, with the
coefcient has changed. In addition, it is impossible to install a ow
orice plate to measure the actual steam leakage quantity.
For some turbines with blowdown valves (BDV), which are
installed on the front of IP section, the N2 leakage quantity can be
calculated by blowdown method [6], and its impact on the ef-
ciency of IP turbine can be analyzed, while it is unfeasible to install
BDV just for this purpose for its high cost and security risks.
Currently, temperature variation method is usually used in the
* Corresponding author.
E-mail address: lilingseu@126.com (L. Li).
Contents lists available at ScienceDirect
Applied Thermal Engineering
j ournal homepage: www. el sevi er. com/ l ocat e/ apt hermeng
1359-4311/$ e see front matter 2010 Elsevier Ltd. All rights reserved.
doi:10.1016/j.applthermaleng.2010.09.011
Applied Thermal Engineering 31 (2011) 311e318
calculation of N2 leakage [7], Caudill and Griebenow [8] explained
the principles of the temperature variation method, and Ray Beebe
[9] demonstrated a case of practical application.
However, all the methods mentioned above does not analyze
the inuence of the leakage on the IP turbine efciency effectively,
so the author presented a new calculation method e numerical
calculation method [10], which cannot only calculate the leakage as
exactly as temperature variation method, but also can analyze the
inuence of leakage on the IP turbine in detail. In order to improve
this method, the N2 leakage rate error analysis equations as the
further development of numerical calculation method are derived
in this paper.
Aiming to explain the numerical calculation method exactly,
the temperature variation method with its issues in application
and numerical calculation method are both concerned in this
paper. What is more, the impact of measured parameters (such as
pressure, temperature) error on the results of the leakage calcu-
lation is analyzed in detail. As there are N2 leakage and N1
leakage, the measured parameters are not the actual parameters
of IP turbine ow path, and the tested IP turbine efciency is not
the actual value. In order to calculate the IP turbine efciency
accurately [11], these two leakages must be taken into account
together. A supercritical 600 MW steam turbine is taken as an
example to illustrate the theory above.
2. Temperature variation method
2.1. Temperature variation method principles
The steam behind HP turbine rst-stage leaks into IP turbine
through N2 internal packing actually, there is a little amount of
other steam ow, such as intercalated layer leakage between HP
inside and outside cylinder, and Warren Hopson [12,13] specied
these leakage. Since this paper is not a study on the inuence of N2
leakage on steam ow in IP turbine rst-stage, rotor cooling and
heat transfer, therefore, it is reasonable to approximately assume
that N2 leakage mixes with hot reheat steamat IP turbine inlet, and
the mixed steam ows through IP turbine ow path.
Several N2 leakage rates are assumed between design value and
maximumvalue, and IP turbine efciency is calculated respectively
with each rate. IP turbine inlet parameters are the mixture
parameters, which is mixed by assumed N2 leakage and hot reheat
steam, and the outlet parameters are the IP turbine exhaust
measured parameters.
Nomenclature
Dh enthalpy drop, kJ/kg
x N2 leakage rate, %
h
R
hot reheat steam enthalpy, kJ/kg
h
I
HP turbine rst-stage outlet enthalpy, kJ/kg
h
c
IP turbine exhaust enthalpy, kJ/kg
Dh
t
ideal enthalpy drop, kJ/kg
h
i
IP turbine efciency, %
Dx variable quantity of N2 leakage rate variation, %
Dh
I
variable quantity of HP turbine rst-stage outlet
enthalpy, kJ/kg
Dh
c
variable quantity of IP turbine exhaust enthalpy, kJ/kg
Dh
R
variable quantity of hot reheat steam enthalpy, kJ/kg
D(Dh
t
) variable quantity of ideal enthalpy drop, kJ/kg
k adiabatic exponent for steam
R
g
gas constant for steam, kJ/(kg.K)
DT variable quantity of temperature, K
Dp variable quantity of pressure, MPa
p
2
outlet steam pressure, MPa
T
2
outlet steam temperature, K
p
1
inlet steam pressure, MPa
T
1
inlet steam temperature, K
c
p
specic heat at constant pressure, kJ/(kg.K)
a
gl
N1 leakage quantity, kg
h
gp
HP turbine exhaust enthalpy, kJ/kg
a
4
fourth extraction quantity (to deaerator and feedwater
pump turbine), kJ/kg
h
zp
enthalpy of steam in crossover pipe, kJ/kg
h
4
fourth extraction enthalpy, kJ/kg
Subscripts
I HP turbine rst-stage
1 inlet of steam turbine
2 outlet of turbine
Superscripts

0
the parameter is for the second test condition
fourth steam
extraction
Crossover pipe
between IP and LP
HP exhaust balance piston
HP exhaust
check valve
Equilibrium pipe
steam baffle
IP balance piston
Measurement
point
Measurement point of
HP exhaust zone
Measurement point
of IP exhaust
Equilibrium pipe
N2 leakage
N1 leakage
N1 leakage
Fig. 1. N1 leakage and N2 leakage.
J.-q. Xu et al. / Applied Thermal Engineering 31 (2011) 311e318 312
Then the relationship curve between N2 leakage rate and IP
turbine efciency is depicted, which is named test 1. Corresponding
to the same IP turbine exhaust parameters, the IP turbine efciency
is higher with the smaller assumed N2 leakage rate, because the
effective enthalpy drop increases, while the ideal enthalpy drop is
near constant. Therefore, N2 leakage rate vs IP turbine efciency
curve is descending. There must be a point inthe curvewhichmeans
the actual N2 leakage rate and IP turbine efciency, but these two
parameters are both unknown, so the solution demands an addi-
tional condition keeping N2 leakage rated and IP turbine efciency
equal to the test 1, i.e. the owof HP and IP turbines remains nearly
unchanged in the other operating condition. That is, HP rst-stage
pressure, hot reheat steampressure and IP turbine exhaust pressure
should be almost equal to the corresponding pressure of test 1.
Only the change in main steamtemperature or hot reheat steam
temperature satises this requirement. For example, reduce the hot
reheat steam temperature, then according to the measured IP
turbine exhaust parameters, use the same method mentioned
above, the relationship curve between N2 leakage rate and IP
turbine efciency, test 2, can be depicted on the same graph with
test 1 curve. As the hot reheat steamtemperature decreases, the N2
leakage quantity decreases, and the effective enthalpy drop
increases, but the ideal enthalpy drop increases slightly, therefore
the IP turbine efciency raises up on a small scale, showing this N2
leakage rate has slight affection on IP turbine efciency. Therefore,
the slope of test 2 is smaller than that of test 1, and then two curves
have an intersection, which indicates the same IP turbine efciency
of the two test conditions, and shows the actual IP turbine ef-
ciency and true N2 leakage rate.
2.2. Temperature variation method practical application issues
(1) HP turbine rst-stage temperature
The enthalpyafter the HPrst-stage is usedinthe N2leakagerate
calculation process. For the steam turbine unit with nozzle gov-
erning, if the valve position of each nozzle regulator is different,
the HP turbine rst-stage temperature distribution will be
uneven in the circumferential direction. So it is better to operate
with single valve, nozzle regulators fully open, or two conditions
withsame valve position. Another advantage of doing sois that, if
HP turbine rst-stage temperature measuring point is out of
control, the HP turbine rst-stage steam temperature can be
calculated according to estimated stage efciency, with the
systematic errors under the extent permitted.
(2) Temperature variation Extent and test load
As shown in Fig. 2, the angle between the two curves will be
smaller if the temperature difference between the two test
conditions is smaller. Then, even a small error of measured
parameters can lead to a larger error on the test results. As it is
the major problem that needs to be avoided, the two test
conditions temperature change should be as great as possible,
increasing the angle and IP turbine efciency difference
produced by N2 leakage, and improving the N2 leakage test
accuracy. In N2 leakage test, there are several means to regulate
the steam temperature, among them, swing burner and regu-
lating gas bafe opening degree are the key means. In addition,
test load should be under the full capacity, for the boiler could
have enough room to regulate. At present, the recommended
temperature change range of the two tests is 30 e41.7

C.
(3) Tests stability
If the measured parameters of the two tests have the same
direction deviations and the amounts are similar, N2 leakage
rate will change slightly, or, N2 leakage rate will change greatly,
namely, the major factor that impacts N2 leakage rate is the
deviation direction of measured parameters of the two test
conditions.
3. Numerical calculation method
3.1. Numerical calculation method principles
Approximately, considering N2 leakage mixes with hot reheat
steam before IP turbine rst-stage, the parameters of mixed steam
as IP turbine inlet parameters and the parameters of IP turbine
exhaust as outlet parameters as demonstrated [10], the actual
enthalpy drop Dh of steam in IP turbine is:
Dh
xh
I
h
c
h
R
h
c

1 x
(1)
The IP turbine efciency h
i
is:
h
i

xh
I
h
c
h
R
h
c

Dh
t
1 x
(2)
where, x is the N2 leakage rate(N2 leakage quantity/IP turbine
admission quantity), h
R
is the hot reheat steam enthalpy, h
I
is the
HP turbine rst-stage outlet enthalpy, h
c
is the IP turbine exhaust
enthalpy, Dh
t
is the ideal enthalpy drop of the mixture of N2
leakage and hot reheat steam.
N2 leakage rate and IP turbine efciency are both unknown in
equation (2), therefore, to gain simultaneous solution needs
another equation. In the condition that main steam temperature or
hot reheat steam temperature changed and the other parameters
unchanged, N2 leakage and IP turbine efciency are nearly
constant, for main steam ow and reheat steam ow unchanged
and pressure before and after separation seal and pressure before
each stage unchanged. Therefore, change main steam temperature
and hot reheat steam temperature, keep N2 leakage rate and IP
turbine efciency unchanged, so another operation condition and
another IP turbine efciency equation can be obtained:
h
i

x
_
h
0
I
h
0
c
_

_
h
0
R
h
0
c
_
Dh
0
t
1 x
(3)
The superscript
0
indicates that the parameter is for the second
test condition. Substitute equation (2) into equation (3) and elim-
inate h
i
, then N2 leakage rate x can be acquired.
0.89
0.895
0.9
0.905
0.91
0.915
0.92
0.925
0 0.01 0.02 0.03 0.04 0.05 0.06
N2 leakage rate
I
P

t
u
r
b
i
n
e

e
f
f
i
c
i
e
n
c
y
Fig. 2. IP turbine efciency vs N2 leakage rate.
J.-q. Xu et al. / Applied Thermal Engineering 31 (2011) 311e318 313
x
h
R
h
c
Dh
0
t

_
h
0
R
h
0
c
_
Dh
t
_
h
0
I
h
0
c
_
Dh
t
h
I
h
c
Dh
0
t
(4)
3.2. The error analysis equations based on numerical calculation
method
The enthalpy error and ideal enthalpy drop caused by measured
parameters deviation (temperature or pressure) inuence the
accuracy of N2 leakage rate x, which are analyzed as follows:
1) x variation caused by the error of HP turbine rst-stage
enthalpy h
I
Dx

_
h
R
h
c
Dh
0
t

_
h
0
R
h
0
c
_
Dh
t

__
h
0
I
h
0
c
_
Dh
t
h
I
h
c
Dh
0
c

2

_
Dh
t
Dh
0
I
Dh
0
t
Dh
I
_
(5)
2) x variation caused by the error of IP turbine exhaust enthalpy h
c
Dx
_
Dh
0
c
Dh
t
Dh
c
Dh
0
t
_

__
h
0
I
h
0
c
_
Dh
t
h
I
h
c
Dh
0
t

__
h
0
I
h
0
c
_
Dh
t
h
I
h
c
Dh
0
t

_
h
R
h
c
Dh
0
t

_
h
0
R
h
0
c
_
Dh
t

__
h
0
I
h
0
c
_
Dh
t
h
I
h
c
Dh
0
t

2

_
Dh
0
t
Dh
c
Dh
t
Dh
0
c
_
(6)
3) x variation caused by the error of hot reheat steam enthalpy h
R
Dx
Dh
0
t
Dh
R
Dh
t
Dh
0
R
_
h
0
I
h
0
c
_
Dh
t
h
I
h
c
Dh
0
t
(7)
4) x variation caused by the error of ideal enthalpy drop Dh
t
In analysis of the inuence of the measured parameters error on
steam enthalpy values and ideal enthalpy drop, the ideal gas
formulas [14] are applied for approximate calculation. For ideal gas,
the temperature variation affects enthalpy and pressure variation
(temperature unchanged), and affects the ideal enthalpy drop (for
steam k 1.3, R
g
0.462) as follows:
Dh c
p
DT
k
k 1
R
g
DT (9)
DDh
t
R
g
T
0
_
p
2
p
0
_
1=k
1
p
0
Dp
2
R
g
T
0
_
p
2
p
0
_
1=k
p
2
1
p
2
0
Dp
0
(10)
With equations (9) and (10), enthalpy change Dh and ideal enthalpy
drop change D(Dh
t
) which caused by temperature variation DT and
pressure variation Dp can be calculated, and the corresponding
change of N2 leakage rate can be calculated by substituting Dh, D
(Dh
t
) into equations (5)e(8).
4. Calculation of a practical steam turbine
4.1. N2 leakage test
A 600 MW supercritical steam turbine, model N600-24.2/566/
566, whose N2 leakage rate design value is 1.20%, while the tested
value is 2.55% before overhaul, is conducted N2 leakage test after
overhaul.
The N2 leakage test is carrying out at 3VWO condition, and the
test conditions are: Test 1, keep main steam temperature rated and
reduce the hot reheat steam temperature; test 2, keep hot reheat
steam temperature rated and reduce the main steam temperature;
test 3, keep hot reheat steam and main steam temperature both
rated. Each test lasts for 2 h, and during the test the unit is keeping
well isolated. The measured parameters include: main steam
pressure and temperature, hot reheat steam pressure and
temperature, IP turbine exhaust pressure and temperature, HP
turbine rs-stage pressure and temperature, atmospheric pressure.
At the same time obtain the standard elevation of measuring
points.
After the abnormal data points are removed, average the
monitoring parameters of test 1 and 2. As N2 leakage test requires
higher stability of the test data of test 3, average its test data at the
most stable period. Then use the atmospheric pressure and stan-
dard elevation to amend average pressure to absolute pressure. The
relevant test data are arranged in Table 1.
4.2. N2 leakage rate calculation
Based on the temperature variation method and numerical
calculation method mentioned above, N2 leakage rates are esti-
mated as follows.
(1) Temperature variation method
It is assumed that N2 leakage rates are 0%, 2% and 5% respec-
tively, and IP turbine efciency of each test is calculated, as shown
in Table 2.
According to the results, the relationship curve between N2
leakage rate and IP turbine efciency is plotted (see Fig. 2). The
curves of the three tests cross at three points, so three N2 leakage
rates are available, that is, one N2 leakage rate is calculated by any
two of the three tests in combination, the results are shown in
Table 3. N2 leakage rate takes the result of combination 1,
x 1.669%.
(2) Numerical calculation method
For any combination of two tests in Table 1, N2 leakage rate is
iteratively calculated with formula (4). For the rst iterative
Dx

_
h
0
R
h
0
c
___
h
0
I
h
0
c
_
Dh
t
h
I
h
c
Dh
0
t


_
h
R
h
c
Dh
0
t

_
h
0
R
h
0
c
_
Dh
t
_
h
0
I
h
0
c
_
__
h
0
I
h
0
c
_
Dh
t
h
I
h
c
Dh
0
t

2
DDh
t

h
R
h
c

__
h
0
I
h
0
c
_
Dh
t
h
I
h
c
Dh
0
t


_
h
R
h
c
Dh
0
t

_
h
0
R
h
0
c
_
Dh
t

h
I
h
c

__
h
0
I
h
0
c
_
Dh
t
h
I
h
c
Dh
0
t

2
D
_
Dh
0
t
_
(8)
J.-q. Xu et al. / Applied Thermal Engineering 31 (2011) 311e318 314
calculation, Dh
t
and Dh
0
t
are assumed as the ideal enthalpy drop of
hot reheat steam, and in each subsequent iterative calculation Dh
t
and Dh
t
are assumed as the ideal enthalpy drop of the mixed steam.
After 10 iterations, the change of x is less than 10
7
, then it can be
said that x has been convergent, and the iteration is over, three N2
leakage rates are available, showing as Table 3. The N2 leakage rate
is x 1.655%.
As shown in Table 3, for a combination of any two tests in Table
1, N2 leakage rates estimated by temperature variation method and
numerical calculation method are almost identical. The N2 leakage
rate calculated by combination 1 is between combination 2 and
combination 3, and the difference is extremely small, indicating
great precision. N2 leakage rate is taken as the result calculated by
combination 1, because the denominator of error analysis formulas
of combination 1 are bigger than other combinations, and the same
measured parameters error will cause the smallest error on N2
leakage rate, that is, the N2 leakage rate of combination 1 has the
highest precision.
4.3. Error analysis
Take the N2 leakage rate 1.655% of combination 1 calculated by
numerical calculation method as the reference value, and analyze
the impact of measured parameters error on N2 leakage rate, under
the condition of one measured parameter changed, while other
parameters unchanged.
As can be seen from Table 2, the maximum arithmetic average
error of hot reheat pressure, hot reheat temperature, IP turbine
exhaust pressure, IP turbine exhaust temperature, HP turbine rst-
stage pressure, HP turbine rst-stage temperature of the three tests
are respectively 0.030 MPa, 2.738

C, 0.007 MPa, 2.081

C,
0.120 MPa, 1.265

C. The arithmetic average error is mainly caused
by the uctuation of steam turbine operating condition, and the
measurement error is much smaller than the arithmetic average
error. It is assumed that the measurement error of test 1 is the
maximum arithmetic average error mentioned above, that is, the
relative error of hot reheat pressure, hot reheat temperature, IP
turbine exhaust pressure, IP turbine exhaust temperature, HP
turbine rst-stage pressure and HP turbine rst-stage temperature
are respectively 0.815%, 0.516%, 0.782%, 0.633%, 0.724%, 0.249%.
As follows, the ideal gas formula and IAPWS-IF67 are used to
analyze the change of steam enthalpy and ideal enthalpy drop
caused by measured parameters error (temperature and pressure),
and then the error analysis formulas are used to calculate the
deviation of N2 leakage rate.
(1) The ideal gas formulas
Apply equations (9) and (10) to calculate the change in the
corresponding enthalpy and ideal enthalpy drop caused by
measured parameters error, and then use the error analysis
formulas (5)e(8) to calculate the corresponding deviation of N2
leakage rate, results are shown in Table 4.
As the pressure deviation does not affect the enthalpy value
when use the ideal gas formulas, the Table 4 doesnt give the
inuence of rst-stage pressure error on N2 leakage rate.
(2) IAPWS-IF67
IAPWS-IF67 is used to calculate the change of corresponding
enthalpy and ideal enthalpy drop caused by measured parameters
error. The error of hot reheat pressure, hot reheat temperature and
IP exhaust pressure affects not only the corresponding steam
enthalpy, but also affects the ideal enthalpy drop; while the error of
IP exhaust temperature, rst-stage pressure and rst-stage
temperature only affects the steam enthalpy. Therefore, N2 leakage
rate deviation caused by the measured parameters error above is
the sum of that caused by the error of steam enthalpy and ideal
enthalpy drop. Then error analysis formulas (5)e(8) can be used to
calculate the corresponding deviation of N2 leakage rate, results are
shown in Table 4.
According toTable 4, the deviations of N2 leakage rate calculated
by the ideal gas formulas and IAPWS-IF67 are almost equal, and the
difference of absolute value is less than 0.377%. Thus, in order to
facilitate the engineering application, the ideal gas formulas are
used to analyze N2 leakage rate deviation caused by measured
parameters error, with sufcient accuracy; in condition of other
parameters unchanged and only one parameter changed. The error
of hot reheat temperature and IP turbine exhaust temperature has
the greatest impact on N2 leakage rate, next, hot reheat pressure
and IP exhaust pressure, and measurement error of rst-stage
parameters have the least impact on N2 leakage rate.
4.4. N1 leakage quantity and its impact on N2 leakage rate
accuracy
For some turbines, there is some N1 leakage (see Fig. 1). As the
measuring points of IP turbine exhaust are located at the crossover
pipe between IP and LP, the tested IP exhaust temperatures is less
than the actual temperature. Therefore, in order to obtain the real IP
turbine exhaust temperature, N1 leakage quantity of test 3 is
calculated in this paper.
N1 leakage enters the exhaust pressure area by two routes after
completely mixed, that is, one ows into the crossover pipe, and the
other ows into the fourth extraction paragraphs, with the consid-
eration that the amount of these two routes are equal, and N1
leakageenthalpy has the same value of HP turbine exhaust enthalpy.
The parameters required for calculation are shown in Table 5.
According to mass conservation and energy conservation,
there are,
a
gl
2
h
gp

_
a
4

a
gl
2
_
h
zp
a
4
h
4
(11)
Table 2
Value of IP turbine efciency.
N2 leakage rate 0% 2% 5%
IP efciency/% Test 1 91.664 90.980 89.999
Test 2 92.070 90.897 89.206
Test 3 91.851 90.926 89.594
Table 3
Results of N2 leakage rates.
Calculation method Combination 1 Combination 2 Combination 3
Temperature variation 1.669% 1.815% 1.522%
Numerical calculation 1.655% 1.763% 1.543%
Table 1
Test Data of N2 leakage test.
Parameters Test 1 Test 2 Test 3
Main steam pressure (MPa) 23.564 22.922 23.617
Main steam temperature (

C) 558.351 529.790 561.255


Hot reheat pressure (MPa) 3.682 3.745 3.772
Hot reheat temperature (

C) 531.085 564.097 567.721


IP exhaust pressure (MPa) 0.895 0.915 0.922
IP exhaust temperature (

C) 328.714 355.107 358.556


First-stage pressure (MPa) 16.574 16.166 16.630
First-stage temperature (

C) 508.710 478.301 508.344


J.-q. Xu et al. / Applied Thermal Engineering 31 (2011) 311e318 315
where, a
gl
is the N1 leakage quantity, h
gp
is the HP turbine exhaust
enthalpy, a
4
is the fourth extraction quantity (to deaerator and
feedwater pump turbine), h
zp
is the enthalpy of steam in crossover
pipe, h
4
is the fourth extraction enthalpy. The N1 leakage quantity
calculated by equation (11) is 8.729 t/h.
The leakage quantity from HP exhaust steam balance piston to
crossover pipe is 4.365 t/h (half of N1 leakage quantity). It is
assumed that IP turbine exhaust pressure remains same before and
after steam mixing, then obtain the actual IP turbine exhaust steam
temperature of test 3, which is 358.895

C, 0.338

C higher than the
measured temperature. Similarly, N1 leakage of test 1 and 2 are
8.845 t/h and 8.398 t/h, and the actual IP exhaust temperature of
test 1 and 2 are 328.959

C and 355.539

C, 0.246

C and 0.432

C
higher than the measured temperature.
Combine the actual IP turbine exhaust temperature obtained
here with the parameters inTable 1, to calculate N2 leakage rates by
using the two methods, results are showed in Table 6, and N2
leakage rate-IP turbine efciency curves, according to temperature
variation method, are shown in Fig. 3.
Basedonthe calculationabove, it is obvious that N1leakage affects
N2 leakage rate accuracy greatly. Although, in the three tests, N1
leakage quantity remains almost the same, but N1 leakage enthalpy
and IP exhaust enthalpy between any two tests have large discrep-
ancy, that is, IP exhaust temperature of the three tests are all greater
than the value without leakage, but the increment between each test
is great, so N1 leakage has a great impact on N2 leakage rate.
5. Check of IP turbine efciency
5.1. IP turbine efciency calculation
The thermodynamic process line of IP turbine is shown in Fig. 4.
IP turbine inlet and outlet measured parameters of test 3 are given
in Table 1, and measured IP turbine efciency is 91.849%, with the
thermal process line 2e3. Impact of Steam leakage on IP thermal
process is shown in Fig. 4: point 1, actual IP turbine inlet point
considering the impact of N2 leakage; point 2, measured parame-
ters of IP turbine inlet (hot reheat) point; point 3, measured IP
turbine outlet point; point 4, actual IP turbine outlet points
(IP turbine exhaust).
Based on the steamleakage quantity calculated above, the actual
IP turbine efciency of test 3 can be calculated as follows.
(1) Consider N2 leakage only
N2 leakage rate takes the value 1.334%, which calculated by
temperature variation method in Section 4.4. At this point, the
steam enthalpy of IP turbine inlet is 3597.235 kJ/kg, inlet steam
temperature is 566.053

C, the outlet parameter is the measured
value, and the corresponding thermal process line is 1e3, as
a result, the IP turbine efciency is 91.096%, 0.753% lower than the
measured value.
(2) Consider N1 leakage only
Table 4
Impact of measured parameters error on the results of N2 leakage according to ideal gas property formulas IAPWS-IF67 (reference value of N2 leakage rate is 1.655%).
Measured parameters Hot reheat
pressure
Hot reheat
temperature
IP exhaust
pressure
IP exhaust
temperature
First-stage
pressure
First-stage
temperature
Relative error of measured parameters/% 0.815 0.516 0.782 0.633 0.249 0.724
Change in N2 leakage rate (ideal gas)/% 1.362 3.561 1.245 2.751 0 0.027
Change in N2 leakage rate (IAPWS-IF67)/% 1.571 3.264 1.409 3.128 0.018 0.043
Absolute value of difference of N2 leakage rate
change/%
0.209 0.297 0.164 0.377 0.018 0.016
Table 5
Data used to calculate N1 leakage quantity.
Parameters Unit HP exhaust zone Fourth steam extraction Crossover pipe
Pressure Mpa 4.058 0.963 0.922
Temperature

C 305.595 356.514 358.556
Enthalpy kJ/kg 2975.988 3173.029 3178.096
Flow rate t/h e 174.098 1239.959
Table 6
Results of N2 leakage rates (according to the actual IP turbine exhaust temperature).
Calculation method Combination 1 Combination 2 Combination 3
Temperature variation 1.334% 1.399% 1.267%
Numerical calculation 1.321% 1.404% 1.237%
0.885
0.89
0.895
0.9
0.905
0.91
0.915
0.92
0.925
0 0.01 0.02 0.03 0.04 0.05 0.06
N2 leakage rate
I
P

t
u
r
b
i
n
e

e
f
f
i
c
i
e
n
c
y
Fig. 3. N2 leakage rate vs IP turbine efciency (according to the actual IP exhaust
temperature).
Fig. 4. IP turbine thermodynamic process.
J.-q. Xu et al. / Applied Thermal Engineering 31 (2011) 311e318 316
At this point, the steam enthalpy of IP turbine outlet is
3178.810 kJ/kg, outlet steam temperature is 358.895

C, the inlet
parameter is the measured value, and the corresponding thermal
process line is 2e4, thence the IP turbine efciency is 91.694%,
0.155% lower than the measured value.
(3) Consider the two leakages
At this condition, the steam enthalpy of IP inlet is 3597.235 kJ/
kg, inlet steam temperature is 566.053

C, the steam enthalpy of IP
turbine outlet is 3178.810 kJ/kg, outlet steam temperature is
358.895

C, and the corresponding thermal process line is 1e4, so
the IP turbine efciency is 91.075%, 0.774% lower than the
measured value.
In order to compare the impact of the two steam leakages on IP
turbine efciency under different operation conditions, calculation
is done on the basis of the steam turbine design data (see Fig. 5).
That is, load operation condition from 30% to 100%: as consider the
impact of N2 leakage, IP turbine efciency is 0.253%e0.636% lower
than the measured value; taking N1 leakage into account, IP turbine
efciency is 0.089%e0.187% lower than the measured value; IP
turbine efciency is 0.341%e0.823% lower than the measured
value, considering the impact of both two leakages.
5.2. The expression of IP turbine efciency deviation
The expression of IP turbine efciency is dened by:
h
i

Dh
Dh
t

h
1
h
2
h
1
h
1t

T
1
T
2
T
1
_
1
_
p2
p1
_k1
k
_
1
T2
T1
1
_
p2
p1
_k1
k
(12)
where, subscript 1 indicates IP turbine inlet, and 2 indicates IP
turbine outlet.
N2 leakage and N1 leakage affect IP turbine inlet and outlet
temperatures. As the leakage quantity compared to the main steam
ow rate is small, it is assumed that the pressure of IP inlet and
outlet are not affected. The deviation of IP turbine efciency can be
calculated approximately by the formula as follows:
Dh
i

1
1
_
p2
p1
_k1
k
_
T
2
T
2
1
DT
1

1
T
1
DT
2
_
(13)
According to equation (13): Steam leakage affects the IP turbine
efciency through the inuence of IP turbine inlet and outlet
temperatures; for the same inlet and outlet temperature variation
DT
1
and DT
2
, outlet temperature variation affects IP turbine ef-
ciency greater than that of inlet temperature. In the condition of the
same quantity of N2 leakage and N1 leakage, the IP turbine inlet
temperature variation DT
1
is greater than the outlet temperature
variation DT
2
, mainly because only half of N1 leakage entering the
crossover pipe between IP and LP. Therefore, N2 leakage has
a greater impact on IP turbine efciency.
6. Conclusions
(1) Due to the installation gap bias and the N2 packing seal friction
during operation, N2 leakage is often greater than the design
value, which affects the steam turbine economy. The actual
leakage rate of the 600 MW unit in this paper used to be about
2.13 times of the design value, while after overhaul the N2
leakage rate is close to the design value, and N1 leakage
quantity reaches to the design value, showing the good effects
of overhaul.
(2) The N2 leakage test theory of temperature variation method
and the issues should be noticed in practical application are
discussed in this paper, owning the actual operation guiding
signicance.
(3) As can be seen from the calculations above, the N2 leakage
rates calculated by numerical calculation and temperature
variation method are almost identical, indicating that the
numerical calculations method also can estimate N2 leakage
rate successfully, and can be used to simplify on-line calcula-
tion, achieving real-time monitoring of N2 leakage rate.
(4) The error analysis shows that the most inuential parameters
on the accuracy of N2 leakage rate are hot reheat steam
temperature and IP exhaust steam temperature, so it is critical
to ensure the temperature measurement accuracy in the test.
(5) The application of ideal gas formula or IAPWS-IF67 for the
analysis of N2 variation caused by measured parameters error
nearly has the same accuracy. To facilitate the analysis and
engineering application, can apply the ideal gas formula to
analyze the impact of measured parameters (temperature and
pressure) error on N2 leakage rate.
(6) In order to estimate N2 leakage more accurately, IP exhaust
temperature measuring points must be ranked in the nal
stage of IP turbine, or calculate N1 leakage quantity and then
nd the exact IP exhaust temperature, as the N1 leakage affects
the test accuracy of N2 leakage rate greatly.
(7) With the same leakage quantity, N2 leakage has greater impact
on IP efciency than N1 leakage.
The impact of N1 and N2 leakage on IP turbine efficiency under different operation conditions
90.000%
90.500%
91.000%
91.500%
92.000%
92.500%
100% 75% 50% 40% 30%
load
I
P

t
u
r
b
i
n
e

e
f
f
i
c
i
e
n
c
y
tested IP turbine efficiency
IP turbine efficiency,considering N1
leakage
IP turbine efficiency,considering N2
leakage
IP turbine efficiency,considering the
two leakages
Fig. 5. Impact of N1 leakage and N2 leakage on IP turbine efciency under different operation conditions.
J.-q. Xu et al. / Applied Thermal Engineering 31 (2011) 311e318 317
Acknowledgements
The tests in this paper were nished with the help of the
researcher Xiao-ling Zhu, who helped us to do these tests exactly,
and provided us a lot of valuable experience.
References
[1] T. Fiadjoe, Estimating HPeIP midspan packing leakage in combined cycles,
Eng. Gas Turbines Power 30 (2) (2008) 023007.1e023007.4.
[2] J.D. Denton, Loss mechanisms in turbomachines, Turbomachinery 115 (1993)
621e656.
[3] T.S. Kim, K.S. Cha, Comparative analysis of the inuence of labyrinth seal
conguration on leakage behavior, Mech. Sci. Technol. 23 (2009) 2830e2838.
[4] J. Li, S.R. Kong, X. . Yan, et al., Numerical investigations on leakage perfor-
mance of the rotating labyrinth honeycomb seal, Eng. Gas Turbines Power 132
(2010) 062501.1e062501.10.
[5] L.S. Andres, J. Baker, A. Delgado, Measurements of leakage and power loss in
a hybrid brush seal, Eng. Gas Turbines Power 131 (2009) 012505.1e012505.6.
[6] J.A. Booth, D.E. Kantemann, Estimating the Leakage from HP to IP Turbine
Section, EPRI power plant performance monitoring conference/workshop,
Washington, DC; October 24, 1984.
[7] X.H. Jiang, Z.Q. Cao, N2 leakage test for HP-IP combined casing, Therm Turbine
35 (3) (2003) 184e187 (in Chinese).
[8] M.B. Caudill, R.D. Griebenow, P.E. Santee Cooper, Analysis of leakage between
HP and IP Turbines using PEPSE, PEPSE Users Group Meeting, Rochester, New
York; June, 1991, com/papers/1991.
[9] R. Beebe, Monitoring Central Gland Leakage on Combined HP-IP Casing steam
turbines, in: Proceedings of the rst World Congress on Engineering Asset
Management (WCEAM), Gold Coast, Australia; 2006. p. 11e4.
[10] J.Q. Xu, X.H. Jiang, Z.Q. Cao, The calculation and error analysis for HPeIP
midspan packing leakage in steam turbines, Therm Turbine 38 (2009)
102e105 (in Chinese).
[11] H. Jiang, H. Li, Z.W. Wang, et al., Determination of target valve for steam
Turbines cylinder efciency, Therm Power Gener. 37 (7) (2008) 15e19
(in Chinese).
[12] W. Hopson, Finding and xing leakage within combined HPeIP steam
turbines: Part I, Power 115 (7) (2007) 26e33.
[13] W. Hopson, Finding and xing leakage within combined HP-IP steam
turbines: Part II, Power 115 (8) (2007) 35e43.
[14] J.B. Jones, R.E. Dugan, Engineering Thermodynamics. Prentice Hall Inc, New
Jersey, 1996.
J.-q. Xu et al. / Applied Thermal Engineering 31 (2011) 311e318 318