Anda di halaman 1dari 36

H1 Axial Piston Pump Size 147/165, Single Technical Information

H1 Axial Piston Pump, Size 147/165, Single Technical Information Revisions


Revision History Table of revisions
Date 30 Jul, 2009 Dec 2009 May 2010 Jul, 2010 Nov 2010 Mar 2011 Page 2, 8, 9, 14-16, 24 5 4-6, 10, 12-13 4, 9-10, 20, 36 8-9 Changed First edition Tables Table updated New EC directive Table updated, new back cover Model code updated Rev AA AB AC BA BB BC

Further available literature


Description SD order number Overview, H1 Axial Piston Pumps, Single and Tandem L1012919 Basic Information, H1 Axial Piston Pumps, Single and Tandem 11062168 Technical Information Standard controls AC Automotive control H1 Axial Piston Pump, Size 045/053, Single 11063344 11076185 H1 Axial Piston Pump, Size 045/053, Tandem 11063345 H1 Axial Piston Pump, Size 060/068, Single 11071685 L1003703 H1 Axial Piston Pump, Size 078, Single 11062169 11068353 H1 Axial Piston Pump, Size 089/100, Single 11069970 11071849 H1 Axial Piston Pump, Size 115/130, Single 11063346 11071850 H1 Axial Piston Pump, Size 147/165, Single 11063347 Complementary Products External Remote Charge Pressure Filter 11064579 Speed and Temperature Sensor 11046759 Pressure Sensor L1007019 Hydraulic Fluids, Technical Information Hydraulic Fluids and Lubricants 520L0463 Experience with Biodegradable Hydraulic Fluids 520L0465 Design Guideline for Hydraulic Fluid Cleanliness 520L0467 Application Information Applications Manual, Section 1, Selection of Driveline Components BLN-9885 Applications Manual, Section 2, Pressure and Speed Limits for Hydraulic Units BLN-9884 Applications Manual, Section 4, Transmission Circuit Recommendations BLN-9886 PLUS+1 COMPLIANT (Electrical Installation) H1 Electrical Displacement Control (EDC) 11022744 H1 3-position (FNR) Electric Control 11025001 H1 Non-Feedback Proportional Electric (NFPE) Control 11025002 Service Manuals H1 Axial Piston Pump, Size 045/053, Single 520L0958 H1 Axial Piston Pump, Size 045/053, Tandem 520L0928 H1 Axial Piston Pump, Size 078/115/130/147/165, Single 520L0848
T000 143E

2011 Sauer-Danfoss. All rights reserved. Sauer-Danfoss accepts no responsibility for possible errors in catalogs, brochures and other printed material. Sauer -Danfoss reserves the right to alter its products without prior notice. This also applies to products already ordered provided that such alterations can be made without affecting agreed specifications. All trademarks in this material are properties of their respective owners. Sauer-Danfoss, the Sauer-Danfoss logotype, the Sauer-Danfoss S-icon, PLUS+1, What really matters is inside and Know-How in Motion are trademarks of the Sauer-Danfoss Group. Front cover illustrations: F301 350, P005 265

11063347 Rev BC Mar 2011

H1 Axial Piston Pump, Size 147/165, Single Technical Information Content

Technical Specifications General Technical Specifications

Technical Specifications................................................................................................................................ 4 Shaft Loads........................................................................................................................................................ 6 Mounting Flange Loads................................................................................................................................ 7 Electrical Displacement Control (EDC) Options A2 (12 V)/A3 (24 V)...........................................10 Manual Over Ride (MOR)............................................................................................................................12 Displacement Limiter...................................................................................................................................13 Input Shafts.....................................................................................................................................................14 Option G3, ISO 3019-1, outer dia 44 mm-4 (SAE D, 13 teeth)..................................................14 Option G2, ISO 3019-1, outer dia 44 mm-4 (SAE D, 27 teeth)..................................................14 Option F3, ISO 3019-1, Code 44-3, Diameter 44.5 taper 1:8, without key and no through-hole in the end of the shaft................................................................................................15 Auxiliary Mounting Pads. ............................................................................................................................16 Option H2, ISO 3019-1, flange 82-2 (SAE A, 9 teeth)...................................................................16 Option H1, ISO 3019-1, flange 82-2 (SAE A, 11 teeth) ...............................................................17 Option H3, ISO 3019-1, flange 101-2 (SAE B, 13 teeth)...............................................................18 Option H5, ISO 3019-1, flange 101-2 (SAE B-B, 15 teeth)..........................................................19 Option H6, ISO 3019-1, flange 127-4 (SAE C, 14 teeth)..............................................................20 Option H5, ISO 3019-1, flange 152-4 (SAE D, 13 teeth)..............................................................21 Charge Pump..................................................................................................................................................22 Port Description. ...........................................................................................................................................24 Dimensions. ....................................................................................................................................................26 Controls.......................................................................................................................................................29 Displacement limiters............................................................................................................................30 Displacement limiters............................................................................................................................31

Dimensions

Charge Pump Installation Drawings

11063347 Rev BC Mar 2011

H1 Axial Piston Pump, Size 147/165, Single Technical Information Technical Specifications
Technical Specifications For definitions of the following specifications, see Basic Information 11062168, Operating parameters. General specifications
Design Direction of rotation Pipe connections Axial piston pump of cradle swashplate design with variable displacement Clockwise, counterclockwise Main pressure ports: ISO split flange boss Remaining ports: SAE straight thread O-ring boss Pump installation position is discretionary, however the recommended control position is on the top or at the side, with the top position preferred. If the pump is installed with the control at the bottom, flushing flow must be provided through port M14 located on the EDC, FNR and NFPE control. Vertical input shaft installation is acceptable. If input shaft is at the top 1 bar case pressure must be maintained during operation. The housing must always be filled with hydraulic fluid. Recommended mounting for a multiple pump stack is to arrange the highest power flow towards the input source. Consult Sauer-Danfoss for nonconformance to these guidelines. Will be inlet pressure with internal charge pump. For reference see operating parameter on next page. Will be case pressure with external charge supply. Please verify mating pump shaft seal capability.
T000 126E

Recommended installation position

Auxiliary cavity pressure

Technical data
Feature Unit Size 147 Size 165 [in3] 147.2 [8.98] 165.1 [10.08] Displacement* cm3 Flow at rated (continuous) speed* l/min [US gal/min] 441 [117] 495 [131] Torque at maximum displacement [lbfin/ Nm/bar 2.34 [1430] 2.63 [1605] (theoretical)* 1000psi] Mass moment of inertia of rotating [slugft2] 0.027 [0.0199] kgm2 components Mass [weight] dry (without charge pump or auxiliary mounting kg [lb] 96.0 [211.0] flange) Oil volume liter [US gal] 3.0 [0.8] Mounting flange ISO 3019-1 flange 152-4 (SAE D) ISO 3019-1, outer dia 44 mm - 4 (SAE D, 13 teeth) Input shaft outer diameter, ISO 3019-1, outer dia 44 mm - 4 (SAE D, 27 teeth) splines and tapered shafts Conical keyed shaft end similar to ISO 3019-1 code 44-3, taper 1:8 ISO 3019-1, flange 82 - 2, outer dia 16 mm - 4 (SAE A, 9 teeth) ISO 3019-1, flange 82 - 2, outer dia 19 mm - 4 (SAE A, 11 teeth) Auxiliary mounting flange with metric ISO 3019-1, flange 101 - 2, outer dia 22 mm - 4 (SAE B, 13 teeth) fasteners, ISO 3019-1, flange 101 - 2, outer dia 25 mm - 4 (SAE B-B, 15 teeth) shaft outer diameter and splines ISO 3019-1, flange 127 - 4, outer dia 32 mm - 4 (SAE C, 14 teeth) ISO 3019-1, flange 152 - 4, outer dia 44 mm - 4 (SAE D, 13 teeth) Suction port Port ISO 11926-1 1 5/8 -12 (SAE O-ring boss) Main port configuration 31.5 - 450 bar split flange boss per ISO 6162, M12x1.75 Case drain ports L2, L4 Port ISO 11926-1 1 5/16 -12 (SAE O-ring boss) (SAE O-ring boss) Other ports SAE O-ring boss. See installation drawings at the back of this manual. Customer interface threads Metric fasteners
T301 020E

11063347 Rev BC Mar 2011

H1 Axial Piston Pump, Size 147/165, Single Technical Information Technical Specifications
Technical Specifications (continued) Operating parameters
Unit Minimum for internal charge supply at minimum charge pressure. Performance (pressure and displacement) may be limited due to limited control pressure Minimum for external charge supply at minimum charge pressure. Full performance (pressure and displacement) possible at miInput speed min-1 (rpm) nimum charge and control pressure supply Minimum for full performance (pressure and displacement) for internal charge supply at minimum charge and control pressure Rated Maximum Maximum working pressure Maximum pressure System pressure bar [psi] Maximum low loop Minimum low loop pressure Minimum Charge pressure bar [psi] Maximum Minimum (at corner power for EDC) Control pressure bar [psi] Maximum Rated bar (absolute) [in Hg vacuum] Charge pump inlet Minimum (cold start) pressure Maximum bar [psi] Rated Case pressure bar [psi] Maximum Lip seal external pressure Maximum bar [psi] Feature Size 147 500 Size 165

For definitions of the following specifications, see Basic Information 11062168, Operating parameters.

500

1200 3000 3100 450 480 [6525] [6960] 45 10 16 34 17 40 0.7 0.2 4.0 3.0 5.0 0.4 420 450 [650] [145] [232] [493] [247] [580] [9] [24] [58] [44] [73] [5.8] [6090] [6525]

T000 173E

Fluid specifications
Feature Viscosity Intermittent 1) Minimum Recommended range Maximum Minimum (cold start) 3) Recommended range Rated Maximum intermittent 1) Cleanliness per ISO 4406 Eciency (charge pressure filtration) Eciency (suction and return line filtration) mm2/s Unit [SUS] 5 7 12-80 1600 -40 60-85 104 115 [42] [49] [66-370] [7500] [-40] [140-185] [220] [240] 22/18/13 15-20 = 75 (10 10) 35-45 = 75 (10 2) 100 125

Temperature range 2)

[F]

Filtration (recommended minimum)

-ratio

Recommended inlet screen mesh size m 1) Intermittent = Short term t < 1min per incident and not exceeding 2 % of duty cycle based load-life 2) At the hottest point, normally case drain port 3) Cold start = Short term t < 3min, p 50 bar [725 psi], n 1000 min-1(rpm)

T000 129E

11063347 Rev BC Mar 2011

H1 Axial Piston Pump, Size 147/165, Single Technical Information General Technical Specifications
Shaft Loads External radial shaft loads H1 pumps are designed with bearings that can accept some external radial loads. The external radial shaft load limits are a function of the load position and orientation, and the operating conditions of the unit. External radial shaft loads impact lifetime. For lifetime calculations please contact Sauer-Danfoss representative. The maximum allowable radial load (Re) is based on the maximum external moment (Me) and the distance (L) from the mounting flange to the load. It may be determined using the following table and formula. Re = Me / L Radial load position
0 Re

Re 270 Re 90 Re

Me 180 Re
P003 318E

Me = Shaft moment L = Flange distance Re = External force to the shaft Thrust loads should be avoided. Contact factory in the event thrust loads are anticipated.

11063347 Rev BC Mar 2011

H1 Axial Piston Pump, Size 147/165, Single Technical Information General Technical Specifications
Bearing Life (continued) Maximum external shaft load based on shaft deflection
Unit External radial moment Me Nm [lbfin] Size 147/165 140 [1240]
T301 022E

All external shaft loads affect bearing life. In applications with external shaft loads, minimize the impact by positioning the load at 0 or 180 as shown in the figure. Sauer-Danfoss recommends clamp-type couplings for applications with radial shaft loads. Contact your Sauer-Danfoss representative for an evaluation of unit bearing life if you have continuously applied external loads exceeding 25 % of the maximum allowable radial load (Re) or the pump swashplate is positioned on one side of center all or most of the time. Mounting Flange Loads H1 single pump front flange load The moments shown below apply for control orientation top or side (see table and figures). Mounting flange load
Unit Rated moment MR Shock load moment MS Nm [lbfin] Size 147/165 6500 [57 500] 16 300 [144 000]
T301 023E

MR

MS

P001 916

For calculation details refer to H1 Pump Basic Information Manual 11062168, section Mounting Flange Loads.

11063347 Rev BC Mar 2011

H1 Axial Piston Pump, Size 147/165, Single Technical Information General Technical Specifications
Model Code
H1 P A B C D F E G H G J K M N S T V W X Y

Displacement
147 165 147.2 cm [8.98 in] 165.1 cm [10.08 in] Left hand (counter clockwise) Right hand (clockwise) Revision code Electric Displacement Control (EDC) 12V, Deutsch connector Electric Displacement Control (EDC) 24V, Deutsch connector Electric Displacement Control (EDC) 12V, Deutsch connector, Manual override Electric Displacement Control (EDC) 24V, Deutsch connector, Manual override Orifices, 0.8 mm in servo supply 1 and 2, recommended for propel applications Orifices, 1.3 mm in servo supply 1 and 2 (Standard), recommended for propel applications No orifice, recommended for non-propel applications None Adjustable externally (align with option Y: Settings for adjustment, if applicable)

Rotation
L R

B D

Product version
C A2 A3 A4 A5

Control

Orifices
C1 C2 C3

Displacement limiters
N B

Endcap options

Twin port, ISO 6162 Split flange ports Auxiliary mounting pad None, Match ISO 3019-1, flange 82 - 2 (SAE A, 9 and 11 teeth) Auxiliary mounting pad with below ISO 3019-1, flange 101 2 (SAE B, 13 teeth) ISO 3019-1, flange 152 - 4 (SAE D, 13 teeth) options (K) ISO 3019-1, flange 101 - 2 (SAE B-B, 15 teeth) ISO 3019-1, flange 127 - 4 (SAE C, 14 teeth) Match Integral full Remote and external Integral full Remote and external Suction Suction with below charge flow charge supply for full charge flow charge supply for full filtration filtration options (T) filtration charge flow filtration filtration charge flow filtration D3 X D5 X D6 X D7 X D8 X D9 X

H J

Mounting
G G3 G2 F3 ISO 3019-1, flange 152 - 4 (SAE D) ISO 3019-1, outer dia 44 mm - 4 (SAE D, 13 teeth splined shaft 8/16 pitch) ISO 3019-1, outer dia 44 mm - 4 (SAE D, 27 teeth splined shaft 16/32 pitch) Conical keyed shaft end similar to ISO 3019-1 code 44-3, taper 1:8 (key not supplied with pump)

Input shaft

11063347 Rev BC Mar 2011

H1 Axial Piston Pump, Size 147/165, Single Technical Information General Technical Specifications
Model Code (continued)
A B H1 P D F E G H J K M N S T V W X Y

NN NNN NNN

Auxiliary mounting pad (align with option G: Endcap selection)


NN H2 H1 H3 H5 H6 H4 None ISO 3019-1, flange 82 - 2, outer dia 16 mm - 4 (SAE A, 9 teeth 16/32 coupling) ISO 3019-1, flange 82 - 2, outer dia 19 mm - 4 (SAE A, 11 teeth 16/32 coupling) ISO 3019-1, flange 101 - 2, outer dia 22 mm - 4 (SAE B, 13 teeth 16/32 coupling) ISO 3019-1, flange 101 - 2, outer dia 25 mm - 4 (SAE B-B, 15 teeth 16/32 coupling) ISO 3019-1, flange 127 - 4, outer dia 32 mm - 4 (SAE C, 14 teeth 12/24 coupling) ISO 3019-1, flange 152 - 4, outer dia 44 mm - 4 (SAE D, 13 teeth 8/16 coupling)

M N

Overpressure protection type and setting side A ** Overpressure protection type and setting side B **
** Pressure protection type must be the same for side A and B L High pressure relief valve + pressure limiters with bypass High pressure relief valve only with K bypass (no pressure limiters) L20 K20 200 bar [2900 psi] L23 K23 230 bar [3336 psi] L25 K25 250 bar [3630 psi] L28 K28 280 bar [4061 psi] L30 K30 300 bar [4350 psi] L33 K33 330 bar [4786 psi] Use the selection for ports A and B L35 K35 350 bar [5080 psi] L38 K38 380 bar [5510 psi] L40 K40 400 bar [5800 psi] L42 K42 420 bar [6090 psi] L43 430 bar [6237 psi] (147 cm3 only) L44 440 bar [6382 psi] (147 cm3 only) L45 K45 450 bar [6960 psi] (147 cm3 only) Contact factory for pressures not shown or for applied pressure above rated (see system pressure page 5)

Charge pump
A L N 26 cm/rev [1.57 in/rev] 34 cm/rev [2.07 in/rev] No charge pump, external charge supply, (align with Option T: Filtration Options, option E) Suction filtration (see Basic drawings) Integral full charge flow filtration with bypass and bypass sensor, long filter, order number 11004919 Remote full charge flow filtration (see endcap drawings) External charge flow filtration (see endcap drawings), (align with option S: Charge pump, option N) 20 bar [290 psi] 24 bar [348 psi] 30 bar [435 psi] None Black paint and Sauer-Danfoss nametag None

Filtration options (align with option G: Endcap selection)

L M P E

Charge pressure relief setting (contact factory for pressure not shown)
20 24 30

W X Y

Special hardware features


NN NNN NNN

Paint and nametag Special settings


9

11063347 Rev BC Mar 2011

H1 Axial Piston Pump, Size 147/165, Single Technical Information General Technical Specifications
Electrical Displacement Control (EDC) Options A2 (12 V)/A3 (24 V) EDC Principle The Electrical Displacement Control (EDC) consists of a pair of proportional solenoids on each side of a threeposition, four-way porting spool. The proportional solenoid applies a force input to the spool, which ports hydraulic pressure to either side of a double acting servo piston. Differential pressure across the servo piston rotates the swashplate, changing the pumps displacement from full displacement in one direction to full displacement in the opposite direction. Under some circumstances, such as contamination, the control spool could stick and cause the pump to stay at some displacement. A serviceable 125 m screen is located in the supply line immediately before the control porting spool. Pump displacement vs. control current
100 %
Displacement

P003 191

EDC-Schematic diagram
M14 C1 C2

F00B

F00A Feedback from Swash plate

P003 478E

Control signal requirements Control current


Current mA a b a* b Pin mA mA connections 12 V 640 1640 any order 24 V 330 820 * Factory test current, for vehicle movement or application actuation expect higher or lower value. Voltage
T000133E

-b

-a

"0"

Connector

100 %
P003 479E

2 P003 480

Description Mating connector Wedge lock Socket contact (16 and 18 AWG) Sauer-Danfoss mating connector kit

Quantity 1 1 2 1

Ordering number Deutsch DT06-2S Deutsch W2S Deutsch 0462-201-16141 K29657


T000 134E

10

11063347 Rev BC Mar 2011

H1 Axial Piston Pump, Size 147/165, Single Technical Information General Technical Specifications
Electrical Displacement Control (EDC) Options A2 (12 V)/A3 (24 V) (continued) Solenoid data
Voltage Maximum current Coil resistance @ 20 C [70 F] Coil resistance @ 80 C [176 F] PWM Range PWM Frequency (preferred)* Inductance IP Rating (IEC 60 529) + DIN 40 050, part 9 IP Rating (IEC 60 529) + DIN 40 050, part 9 with mating connector * PWM signal required for optimum control performance. 12V 1800 mA 3.66 4.52 70-200 Hz 100 Hz 33 mH IP 67 IP 69K
T000 135E

24V 920 mA 14.20 17.52

140 mH

Flow table
Shaft rotation CW Coil energized* C2 Port A in Port B out Servo port pressurized M5 * For coil location see installation drawings. CCW C1 out in M4 C2 out in M5 C1 in out M4
T000 136E

Control response H1 controls are available with optional control passage orifices to assist in matching the rate of swashplate response to the application requirements (e.g. in the event of electrical failure). Software ramp or rate limiting should be used to control vehicle response in normal operation. The time required for the pump output flow to change from zero to full flow (acceleration) or full flow to zero (deceleration) is a net function of spool porting, orifices, and charge pressure. A swashplate response table is available for each frame indicating available swashplate response times. Testing should be conducted to verify the proper software and orifice selection for the desired response. H1 pumps are limited in mechanical orificing combinations. Software is envisioned as the means to control the swashplate response in normal operating conditions. Mechanical servo orifices are to be used only for fail-safe return to neutral in the event of an electrical failure. Typical response times shown below at the following conditions: p Viscosity and temperature Charge pressure Speed Response times
Stroking direction Neutral to full flow Full flow to neutral 0.8 mm [0.03 in] Orifice 1.3 mm [0.05 in] Orifice 5.8 s 2.1 s 2.4 s 1.6 s No orifice 1.3 s 1.2 s
T301 024

= = = =

250 bar 30 mm2/s (50 C) 20 bar 1800 min-1 (rpm)

[3626 psi] [141 SUS (122 F)] [290 psi]

11063347 Rev BC Mar 2011

11

H1 Axial Piston Pump, Size 147/165, Single Technical Information General Technical Specifications
Manual Over Ride (MOR) All controls are available with a Manual Over Ride (MOR) either standard or as an option for temporary actuation of the control to aid in diagnostics. Forward-Neutral-Reverse (FNR) and Non Feedback Proportional Electric (NFPE) controls are always supplied with MOR functionality. Unintended MOR operation will cause the pump to go into stroke. The vehicle or device must always be in a safe condition (i.e. vehicle lifted off the ground) when using the MOR function. The MOR plunger has a 4 mm diameter and must be manually depressed to be engaged. Depressing the plunger mechanically moves the control spool which allows the pump to go on stroke. The MOR should be engaged anticipating a full stroke response from the pump. Warning An o-ring seal is used to seal the MOR plunger where initial actuation of the function will require a force of 45 N to engage the plunger. Additional actuations typically require less force to engage the MOR plunger. Proportional control of the pump using the MOR should not be expected. Refer to control flowtable for the relationship of solenoid to direction of flow.

P003 204

MOR-Schematic diagram (EDC shown)


M14

C1

C2

F00B

F00A Feedback from Swash plate

P
P003 205E

12

11063347 Rev BC Mar 2011

H1 Axial Piston Pump, Size 147/165, Single Technical Information General Technical Specifications
Displacement Limiter H1 pumps are designed with optional mechanical displacement (stroke) limiters factory set to max. displacement. The maximum displacement of the pump can be set independently for forward and reverse using the two adjustment screws to mechanically limit the travel of the servo piston down to 50 % displacement. Adjustment procedures are found in the H1 pumps Service Manual. Adjustments under operating conditions may cause leakage. The adjustment screw can be completely removed from the threaded bore if backed out to far. Displacement limiter

P003 266

Displacement change (approximately)


Size 147 165 1 Turn of displacement limiter screw [0.76 in3] 12.4 cm3 3 13.9 cm [0.85 in3] Internal wrench size 6 mm External wrench size 22 mm Torque for external hex seal lock nut 80 Nm [708 lbfin]
T301 025E

For more information refer to H1 pumps Service Manual 520L0848, section Displacement Limiter Adjustment.

11063347 Rev BC Mar 2011

13

H1 Axial Piston Pump, Size 147/165, Single Technical Information Dimensions


Input Shafts Option G3, ISO 3019-1, outer dia 44 mm-4 (SAE D, 13 teeth)
8.0 [0.316] Coupling must not protrude beyond this Point

Mounting ange surface ange 127 - 4 per ISO 3019-1 to be paint free Spline Data Number of Teeth 67.0 Pitch Fraction [2.638] Pressure Angle Pitch- Typ of Fit 39.5 Per [1.555]

: : : : : :

13 8/16 30 41.275 [1.625] Fillet Root Side Fit Ansi B92.1-1996 Class 5

36.4 0.25 [1.433 0.010]

Shaft to be paint free

44.4 0.09 [1.746 0.004]

P003 272E

Specifications
Option Spline Min active spline length2 Torque rating1 Rated torque Maximum torque Nm [lbfin] Nm [lbfin] 1442 [12 800] 2206 [19 500]

mm [in] G3 13 teeth, 8/16 pitch 39.5 [1.555] 1) For definitions of maximum and rated torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication. 2) Minimum active spline length for the specified torque ratings.

T000 200E

Option G2, ISO 3019-1, outer dia 44 mm-4 (SAE D, 27 teeth)


8.05 [0.317] Coupling must not protrude beyond this point

Mounting ange surface ange 127 - 4 per ISO 3019-1 to be paint free Spline Data Number of Teeth 67.0 Pitch Fraction [2.638] Pressure Angle Pitch- Typ of Fit Per 42.0 [1.654]

: : : : : :

27 16/32 30 42.863 [1.688] Fillet Root Side Fit Ansi B92.1-1996 Class 5

Shaft to be paint free

39.5 1.0 [1.555 0.039]

44.36 0.09 [1.746 0.004]

P003 271E

Specifications
Option Spline Min active spline length2 Torque rating1 Rated torque Maximum torque Nm [lbfin] Nm [lbfin] 1615 [14 300] 3000 [26 550]

mm [in] G2 27 teeth, 16/32 pitch 42.0 [1.654] 1) For definitions of maximum and rated torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication. 2) Minimum active spline length for the specified torque ratings.

T000 201E

14

11063347 Rev BC Mar 2011

H1 Axial Piston Pump, Size 147/165, Single Technical Information Dimensions


Input Shafts (continued) Option F3, ISO 3019-1, Code 44-3, Diameter 44.5 taper 1:8, without key and no through-hole in the end of the shaft
Mounting ange surface Flange 127 - 4 per ISO 3019-1 to be paint free Conical keyed shaft end similar to ISO 3019-1 code 38-3 Suitable key 7/16 x 7/16 x 1 3/4 ANSI B17.1 125 0.5 : 1000 1 1/4 -12

mm [in]

44.45 [1.750]

Shafts to be paint free (54.0) [2.126] 93.7 1.0 [3.689 0.039] 39.7 1.0 [1.563 0.039]

Specifications
Option Tapered shaft

8.025 0.8 [0.361 0.31]

Coupling must not overlap till this point

P301 212

Torque rating1) Rated torque* Maximum torque Nm [lfbin] Nm [lfbin] 1766 [15 630] 2354 [20 830] F3 44-3 taper without key 2) 1) For definitions of maximum and rated torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication. 2) Mating part must maintain a minimum gap width of 1.0 mm with the shaft shoulder after installation of the part. Transmittable torque will be reduced if the minimum gap requirement is not met. * Rated torque includes just the capability of the press-fit in accordance with an assumed fastener grade 5.
T000 202E

Tapered shaft customer acknowledgement The Sauer-Danfoss H1 tapered shaft has been designed using the industry standard ISO 3019-1, minus the through-hole in the end of the shaft. Sauer-Danfoss recommends a self-locking nut instead of a castle nut and pin. The nut and mating square-cut key are customer supplied. The specified torque rating of the tapered shaft documented above is based on the cross-sectional diameter of the shaft, through the keyway, and assumes the proper clamp and fit between shaft and coupling. Sauer-Danfoss guarantees the design and manufactured quality of the tapered shaft. The customer is responsible for the design and manufactured quality of the mating female coupling and key and applied torque on the nut. Sauer-Danfoss has made provisions for the key in accordance to the ISO specification with the understanding that the key is solely to assist in the installation of the mating coupling. CCaution Torque must be transmitted by the taper fit between the shaft and its mating coupling, not the key. Torque or loading inadvertently transmitted by the customer supplied key may lead to premature shaft failure.
11063347 Rev BC Mar 2011

15

H1 Axial Piston Pump, Size 147/165, Single Technical Information Dimensions


Auxiliary Mounting Pads Option H2, ISO 3019-1, flange 82-2 (SAE A, 9 teeth)
346.0 2 [13.621 0.079] Mounting ange surface Flange 82 - 2 per iso 3019-1 to be paint free 330.8 2 [13.025 0.079]

2x 106.4 0.35 [4.189 0.014]

+ 0.13 88.621 0

[3.489 + 0.05 ] 0

+ 0.076 82.601 0

Thread : M10 x 1.5-6H THD Depth : 16 [0.63] min. 4x

O-ring seal required 1.96 ref 82.22 [3.237] I.D. x 2.62 [0.103] cross section [0.077] 8.1 0.25 [0.319 0.010]

[3.252 + 0.003 ] 0

4x 53.2 0.175 [2.094 0.007]

15.3 [0.602]

R 0.8 max. [0.031]

Spline data Number of teeth Pitch fraction Pressure angle Pitch- Typ of t per

: : : : : :

9 16/32 30 14.288 [0.5625] Fillet root side Ansi B92.1-1996 class 6

P003 273E

Specifications
Option Spline Torque rating1 maximum torque [lbfin] [1430]
T000 150E

Nm H2 9 teeth, 16/32 pitch 162 1) For definitions of maximum torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication.

C Caution Standard pad cover is installed only to retain coupling during shipping. Do not operate pump without an auxiliary pump or running cover installed.

16

11063347 Rev BC Mar 2011

H1 Axial Piston Pump, Size 147/165, Single Technical Information Dimensions


Auxiliary Mounting Pads (continued) Option H1, ISO 3019-1, flange 82-2 (SAE A, 11 teeth)
346.0 2.0 [13.621 0.079] 330.8 2 [13.025 0.079]

Mounting ange surface Flange 82 - 2 per iso 3019-1 to be paint free

2x 106.4 0.35 [4.189 0.014] 4x 53.2 0.175 [2.094 0.007]

15.3 1 [0.602 0.039] 82.601 + 0.076 0 88.621 + 0.13 0 [3.489 + 0.05 ] 0 [3.252 + 0.003 ] 0

R 0.8 max. [0.031]

Thread : M10 x 1.5-6H THD Depth : 16.0 [0.63] min. 4x

O-ring seal required ref 82.22 [3.237] I.D. x 2.62 [0.103] cross section

1.96 [0.077]

8.1 0.25 [0.319 0.010]

Spline data Number of teeth Pitch fraction Pressure angle Pitch- Typ of t per

: : : : : :

11 16/32 30 17.463 [0.688] Fillet root side Ansi B92.1-1996 class 6

P003 360E

Specifications
Option Spline Torque rating1 maximum torque [lbfin] [2620]
T000 151E

Nm H1 11 teeth, 16/32 pitch 296 1) For definitions of maximum torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication.

C Caution Standard pad cover is installed only to retain coupling during shipping. Do not operate pump without an auxiliary pump or running cover installed.

11063347 Rev BC Mar 2011

17

H1 Axial Piston Pump, Size 147/165, Single Technical Information Dimensions


Auxiliary Mounting Pads (continued) Option H3, ISO 3019-1, flange 101-2 (SAE B, 13 teeth)
346.5 2 [13.642 0.079] Mounting ange surface Flange 101 - 2 per iso 3019-1 To be paint free 330.8 2 [13.025 0.079]

+ 0.076 101.651 0

+ 0.13 107.823 0

Thread : M12 x 1.75 Depth : 25.0 [0.984] min. 4x

O-ring seal required 1.96 ref 94.92 [3.737] I.D. [0.077] x 2.62 [0.103] cross section 11.4 0.25 [0.449 0.010]

[4.245

+ 0.05 ] 0

[4.002 + 0.003 ] 0

2x 146.0 0.35 [5.748 0.014] 4x 73.0 0.175 [2.874 0.007]

20.3 [0.799]

R 0.8 max. [0.031]

Spline data Number of teeth Pitch fraction Pressure angle Pitch- Typ of t per

: : : : : :

13 16/32 30 20.638 [0.813] Fillet root side Ansi B92.1-1996 class 6

P003 274E

Specifications
Option Spline Torque rating1 maximum torque [lbfin] [3500]
T000 152E

Nm H3 13 teeth, 16/32 pitch 395 1) For definitions of maximum torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication.

C Caution Standard pad cover is installed only to retain coupling during shipping. Do not operate pump without an auxiliary pump or running cover installed.
18
11063347 Rev BC Mar 2011

H1 Axial Piston Pump, Size 147/165, Single Technical Information Dimensions


Auxiliary Mounting Pads (continued) Option H5, ISO 3019-1, flange 101-2 (SAE B-B, 15 teeth)

Mounting ange surface Flange 101 - 2 per iso 3019-1 to be paint free

330.8 2 [13.025 0.079]

346.5 2 [13.642 0.079]

[4.245 + 0.005 ] 0

Thread : M12 x 1.75 Depth : 25.0 [0.984] min. 4x

O-ring seal required ref 94.92 [3.737] I.D. 1.96 x 2.62 [0.103] cross section [0.077] 11.4 0.25 [0.449 0.010]

+ 0.13 107.823 0

+ 0.076 101.651 0

R 0.8 max. [0.031]

[4.002 + 0.003 ] 0

2x 146.0 0.35 [5.748 0.014] 4x 73.0 0.175 [2.874 0.007]

21.3 [0.839]

Spline data Number of teeth Pitch fraction Pressure angle Pitch- Typ of t per

: : : : : :

15 16/32 30 23.813 [0.938] Fillet root side Ansi B92.1-1996 class 6

P003 199E

Specifications
Option Spline Torque rating1 maximum torque [lbfin] [6130]
T000 153E

Nm H5 15 teeth, 16/32 pitch 693 1) For definitions of maximum torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication.

C Caution Standard pad cover is installed only to retain coupling during shipping. Do not operate pump without an auxiliary pump or running cover installed.
11063347 Rev BC Mar 2011

19

H1 Axial Piston Pump, Size 147/165, Single Technical Information Dimensions


Auxiliary Mounting Pads (continued) Option H6, ISO 3019-1, flange 127-4 (SAE C, 14 teeth)

Mounting ange surface Flange 127 - 4 per iso 3019-1 to be paint free

349.5 2 [13.762 0.079] 333.8 2 [13.142 0.079]

+ 0.13 134.06 0 [5.278 + 0.005 ] 0

Thread : M16 x 2-6H THD Depth : 28.5 [1.122] min. 2x Thread : M12 x 1.75 Depth : 28.5 [1.122] min. 4x

4x 57.25 0.175 [2.254 0.007] 2x 114.5 0.35 [4.508 0.014]

O-ring seal required ref 120.32 [4.737] I.D. x 2.62 [0.103] cross section 1.96 [0.077] 15.0 0.25 [0.591 0.010]

+ 0.076 127.05 0

R 0.8 max. [0.031]

[5.002 + 0.003 ] 0

181.0 0.35 [7.126 0.014] 2x 90.5 0.175 [3.563 0.007]

23.3 1 [0.917 0.039]

Spline data Number of teeth Pitch fraction Pressure angle Pitch- Typ of t per

: : : : : :

14 12/24 30 29.633 [1.167] Fillet root side Ansi B92.1-1996 class 6 P003 275E

Specifications
Option Spline Torque rating1 maximum torque [lbfin] [7220]
T000 154E

Nm H6 14 teeth, 12/24 pitch 816 1) For definitions of maximum torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication.

C Caution Standard pad cover is installed only to retain coupling during shipping. Do not operate pump without an auxiliary pump or running cover installed.
20
11063347 Rev BC Mar 2011

H1 Axial Piston Pump, Size 147/165, Single Technical Information Dimensions


Auxiliary Mounting Pads (continued) Option H5, ISO 3019-1, flange 152-4 (SAE D, 13 teeth)

4x 161.6 0.35 [6.362 0.014] 8x 80.8 0.175 Mounting ange surface [3.181 0.007] Flange 152-4 per ISO 3019-1 to be paint free

353.9 2 [13.934 0.079] 333.2 2 [13.119 0.079]

27.48 [1.082]

Thread : M20 x 2.5-6H THD Depth : 30.0 [1.181] min. 4x

O-ring seal required ref 150.0 [5.906] I.D. x 3.0 [0.118] cross section

+ 0.13 159.0 0

[6.260 + 0.005 ] 0 + 0.076 152.45 0

[6.002 + 0.003 ] 0

2.5 [0.098] 14.0 [0.551]

Spline data Number of teeth Pitch fraction Pressure angle Pitch- Typ of t per

: : : : : :

13 8/16 30 41.275 [1.625] Fillet root side Ansi B92.1-1996 class 6

P003 276E

Specifications
Option Spline Torque rating1 maximum torque [lbfin] [19 500]
T000 203E

Nm H4 13 teeth, 8/16 pitch 2206 1) For definitions of maximum torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication.

C Caution Standard pad cover is installed only to retain coupling during shipping. Do not operate pump without an auxiliary pump or running cover installed.
11063347 Rev BC Mar 2011

21

H1 Axial Piston Pump, Size 147/165, Single Technical Information Charge Pump
Charge Pump Charge pump sizing/selection In most applications a general guideline is that the charge pump displacement should be at least 10 % of the total displacement of all components in the system. Unusual application conditions may require a more detailed review of charge flow requirements. Please refer to BLN-9885, Selection of Drive line Components, for a detailed procedure. System features and conditions which may invalidate the 10 % guideline include (but are not limited to): Continuous operation at low input speeds (< 1500 min-1 (rpm)) High shock loading and/or long loop lines High flushing flow requirements Multiple Low Speed High Torque motors High input shaft speeds Contact your Sauer-Danfoss representative for application assistance if your application includes any of these conditions. Charge pump flow and power curves Charge pressure: 20 bar [290 psi] Viscosity and temperature: 11 mm2/s [63 SUS] 80 C [180 F] Charge pump flow
27 100 14.0 13.0 21 80 12.0 11.0 10.0 60 l/min 50 10 9 8 7 6 Kw 5 4 3 2 1 0 0 500 1000 1500 2000 Speed min-1(rpm)
P003 335E

Charge pump power requirements

24

90

18

70

7 in 3 /re v]

15 US gal/min

9.0
n 3/ rev ]

cm 3

[2.0

8.0 HP 7.0 6.0

cm 3

9 30 6 20 3 1 0

4.0 3.0 2.0

10

1.0 2500 3000 3500

500 1000

1500 2000 Speed min-1(rpm)

26 cm 3 [1.

34

59 i

5.0

n 3/ rev ]

40

26 cm 3 [1. 5

[2. 0

7 in 3 /re v]

34

9i

12

2500 3000

3500

P003 337E

22

11063347 Rev BC Mar 2011

H1 Axial Piston Pump, Size 147/165, Single Technical Information Notes


Notes

11063347 Rev BC Mar 2011

23

H1 Axial Piston Pump, Size 147/165, Single Technical Information Installation Drawings
Port Description
Servo gage port M4 Port ISO 11926-1 7/16 -20 24.5 max clearance dia for tting System port B 31.5 450 bar Split ange boss per ISO 6162 M12 x 1.75 20 min full thread depth Connector : Deutsch DT04-2P to be paint free Case pressure port Port ISO 11926-1 1 1/16 -12 41 max clearance dia for tting

CCW Rotation

CW Rotation

System port A 31.5 450 bar Split ange boss per ISO 6162 M12 x 1.75 20 min full thread depth

Case drain port L4 Port ISO 11926-1 1 5/16 -12 63 max clearance dia for tting Charge inlet port S Port ISO 11926-1 1 5/8 -12 69 max clearance dia for tting

System A gage port MA Port ISO 11926-1 9/16-18 28 max clearance dia for tting

Port description
Port A B E F L2 L4 MA MB M3 M4 M5 M14 S Description System port A System port B Charge filtration port, from filter Charge filtration port, to filter Case drain port Case drain port System A gage port System B gage port Charge gage port, after filtering Servo gage port Servo gage port Case gage port Charge inlet port Sizes 31.5 31.5 1 1/16 -12 1 1/16 -12 1 5/16 -12 1 5/16 -12 9/16 -18 9/16 -18 9/16 -18 7/16 -20 7/16 -20 7/16 -20 1 5/8 -12
T301 028E

P003 277E

Please contact Sauer-Danfoss for specific installation drawings


24
11063347 Rev BC Mar 2011

H1 Axial Piston Pump, Size 147/165, Single Technical Information Installation Drawings
Port Description (continued)
Case gage port M14 Port ISO 11926-1 - 7/16 -20 21 max. clearance dia for tting (EDC, FNR, NFPE)

System B gage port MB Port ISO 11926-1 9/16-18 28 max clearance dia for tting Charge pressure construction Port ISO 11926-1 - 5/16 -24

Charge ltration port F Port ISO 11926-1 1 1/16 -12 48 max clearance dia for tting to lter Charge ltration port E Port ISO 11926-1 1 1/16 -12 48 max clearance dia for tting from lter Connector : Deutsch DT04-2P to bee paint free Case pressure port Port ISO 11926-1 1 1/16 -12 41 max clearance dia for tting Servo gage port M5 Port ISO 11926-1 7/16 -20 24.5 max clearance dia for tting

Charge pressure construction Port ISO 11926-1 - 5/16 -24

Case drain port L2 Port ISO 11926-1 5/16 -12 63 max clearance dia for tting

Charge gage port M3 Port ISO 11926-1 9/16 -18 28 max clearance dia for tting after ltering

P003 278E

Please contact Sauer-Danfoss for specific installation drawings


11063347 Rev BC Mar 2011

25

H1 Axial Piston Pump, Size 147/165, Single Technical Information Installation Drawings
Dimensions
Servo Gage Port M4 Port ISO 11926-1 7/16 -20 24.5 max clearance dia for tting System Port B 31.5 450 bar Split Flange Boss per ISO 6162 M12 x 1.75 20 min. Full Thread Depth Charge Inlet Port S Port ISO 11926-1 1 5/8 -12 69 max clearance dia for tting 333.0 0.4 [13.112 0.079] [10.068 + 0.024] 0.02 179.9 1.0 [7.08 0.039] Connector : Deutsch DT04-2P to be paint free 150.0 1.0 [5.91 0.039] 51.9 1.0 [2.04 0.039] Case Pressure Port Port ISO 11926-1 1 1/16 -12 41 max clearance dia for tting 12.45 0.25 [0.49 0.01] 1.5 0.5 x 455 [0.059 0.028 x 45] 182.4 1.0 [7.18 0.039] 155.5 1.0 [6.12 0.039] R 0.8 max. [0.031] 0.1 80.0 + 0.2 [3.15 + 0.004] 0.008 42.0 1.0 [1.65 0.039] +0 152.4 0.05 22.9 0.2 [0.90 0.008] 8.05 0.8 [0.317 0.031] 169.9 1.0 [6.69 0.039] ] [6.0 + 0 0.002 0.6 255.7 + 0.5 Mounting Flange surface ange 127 - 4 per ISO 3019-1 to be paint free

135.0 1.0 [5.31 0.039]

Z
81.5 1.0 [3.21 0.039] 0.1 80.0 + 0.2 + 0.004 ] [3.15 0.008

(4x) 31.8 0.25 [1.25 0.01]

(8x) 15.9 0.25 [0.63 0.01]

67.0 1.0 [2.64 0.039]

(8x) 33.3 0.25 [1.31 0.01] System Port A 31.5 450 bar Split Flange Boss per ISO 6162 M12 x 1.75 20 min. Full Thread Depth (4x) 66.6 0.25 [2.62 0.01]

Case Drain Port L4 Port ISO 11926-1 1 5/16 -12 63 max clearance dia for tting

BB
63.5 0.2 [2.5 0.01]

2x

CC
115.4 0.2 [4.54 0.01]

DD
111.0 0.2 [4.37 0.01]

2x

Shaft C L

Shaft C L

Shaft C L

P003 279E

Please contact Sauer-Danfoss for specific installation drawings


26
11063347 Rev BC Mar 2011

H1 Axial Piston Pump, Size 147/165, Single Technical Information Installation Drawings
Dimensions (continued)
179.9 1.0 [7.08 0.039] 150.0 1.0 [5.91 0.039] Connector: Deutsch DT04-2P to be paint free

Y Z
Servo gage port M5 Port ISO 11926-1 7/16 -20 24.5 max clearance dia for tting Charge pressure constr. port Port ISO 11926-1 5/16 -24 152.6 1.0 [6.01 0.039] 131.9 1.0 [5.19 0.039]

Case pressure port Port ISO 11926-1 1 1/16 -12 41 max clearance dia for tting

51.9 1.0 [2.04 0.039]

1.1 [0.043]

182.4 1.0 [7.18 0.039] 155.5 1.0 [6.12 0.039] 135.0 1.0 [5.32 0.039]

81.5 1.0 [3.21 0.039]

Approximate center of gravity 165.0 [6.496] 169.9 1.0 [6.689 0.039]

Charge gage port M3 Port ISO 11926-1 9/16 -18 28 max clearance dia for tting after ltering Case drain port L2 Port ISO 11926-1 1 5/16 -12 63 max clearance dia for tting

112.0 1.0 [4.41 0.039]

24.3 [0.96]

208.3 1.0 [8.20 0.039]

Approximate center of gravity

F-F
11
Charge ltratio n port Port IS F 48 mO 11926-1 1 a x for ttin clearance 1 /16 -12 dia g to lt er

W
270.7 1.0 [10.66 0.039] 87.9 1.0 [3.46 0.039]

Charge pressure construction port Port ISO 11926-1 5/16 -24 System B gage port MB Port ISO 11926-1 9/16 -18 28 max clearance dia for tting

209 max [8.228] 128.4 2.0 [5.055 0.079] 64.2 1.0 [2.528 0.039]

8.0 1.0 [0.315 0.039] 92.0 1.0 [3.62 0.039]

69.0 1.0 [2.717 0.039]

E-E
11
Charge ltratio n port Port IS 48 mO 11926-1 1 E for tt ax clearanc 1 /16 -12 e ing fro m lte dia r

F E
Case gage port M14 Port ISO 11926-1 7/16 -20 21 max clearance dia for tting 270.72 1.0 [10.658 0.039] 273.42 1.0 [10.765 0.039]

F E

Please contact Sauer-Danfoss for specific installation drawings


11063347 Rev BC Mar 2011

113.6 0.1 [4.472 0.039] P003 280E

Charge ltration port F Port ISO 11926-1 11/16 -12 48 max clearance dia for tting to lter Charge ltration port E Port ISO 11926-1 11/16 -12 48 max clearance dia for tting from lter

113.3 0.1 [4.461 0.039]

27

H1 Axial Piston Pump, Size 147/165, Single Technical Information Installation Drawings
Dimensions (continued)

X
System A gage port MA Port ISO 11926-1 9/16 -18 28 max clearance dia for tting

W
255.7 [10.07]

92.0 1.0 [3.62 0.039]

CCW Rotation

CW Rotation

(4x) 40 0.25 [1.575 0.01] other side screw head space

(4x) 80.8 0.25 [3.18 0.01]

0.25 (4x) 20.6 + 0.13 [0.811 + 0.01 ] 0.005 P003 281E

Please contact Sauer-Danfoss for specific installation drawings


28
11063347 Rev BC Mar 2011

(4x) 80.8 0.25 [3.18 0.01]

H1 Axial Piston Pump, Size 147/165, Single Technical Information Installation Drawings
Dimensions (continued) Controls Electric Displacement Control (EDC), option A2 (12 V) / A3 (24 V)
Connector : Deutsch DT04-2P to be paint free

Case gage port M14 Port ISO 11926-1 7/16 -20 21 max clearance dia for tting 128.4 2.0 [5.055 0.079] 64.2 1.0 [2.528 0.039] 209.0 max [8.228]

Shaft C L

87.9 1.0 [3.46 0.039] 121.9 1.0 [4.8 0.039]

Mounting ange

208.3 max [8.2]

2x 182.4 1.0 [7.18 0.04]

Connector : Deutsch DT04-2P to be paint free 2x 150.0 1.0 [5.91 0.04] P003 340E

Shaft C L

Electric Displacement Control (EDC) with manual override, option A4 (12 V) / A5 (24 V)
Connector : Deutsch DT04-2P to be paint free

Case gage port M14 Port ISO 11926-1 7/16 -20 21 max clearance dia for tting 209.0 max [8.228] 128.4 2.0 [5.055 0.079] 64.2 1.0 [2.528 0.039]

Shaft C L

87.9 1.0 [3.46 0.039] 121.9 1.0 [4.8 0.039]

Mounting ange

208.3 max [8.2]

2x 182.4 1.0 [7.18 0.04]

Connector : Deutsch DT04-2P to be paint free 2x 150.0 1.0 [5.91 0.04] P003 341E

Shaft C L

Please contact Sauer-Danfoss for specific installation drawings


11063347 Rev BC Mar 2011

29

H1 Axial Piston Pump, Size 147/165, Single Technical Information Installation Drawings
Dimensions (continued) Displacement limiters Displacement limiter, option B
153.7 1.0 [6.051 0.039] 176.5 2.0 [6.949 0.079] 176.5 2.0 [6.949 0.079]

2 x Wrench size 6 (external hex)

2 x Wrench size 22 (external hex)

103.3 1.0 [4.067 0.039]

P003 344E

Please contact Sauer-Danfoss for specific installation drawings


30
11063347 Rev BC Mar 2011

H1 Axial Piston Pump, Size 147/165, Single Technical Information Installation Drawings
Dimensions (continued) Displacement limiters Suction filtration, option L
0.6 255.7 + 0.5 [10.068 + 0.024 ] 0.02

Charge pump inlet S Port ISO 11926-1 1 5/8 -12

CC
115.8 0.2 [4.56 0.01]

Shaft C L P003 202E

Please contact Sauer-Danfoss for specific installation drawings


11063347 Rev BC Mar 2011

31

H1 Axial Piston Pump, Size 147/165, Single Technical Information Installation Drawings
Dimensions (continued) Filtration Integral full flow charge pressure filtration with filter bypass sensor, option M

203.265 1.0 [8.003 0.039]

Connector : Deutsch DTM04-2P to be paint free Charge gage port M6 Port ISO 11926-1 9/16 -18 before lter 77.75 1.0 [3.061 0.039] 32.7 1.0 [1.288 0.039]

226.0 2.0 [8.884 0.079]

140.3 2.0 [5.522 0.079]

41.62 2.0 [1.639 0.079]

314.91 1.0 [12.398 0.039] 323.72 1.0 [12.745 0.039]

P003 282E

Please contact Sauer-Danfoss for specific installation drawings


32
11063347 Rev BC Mar 2011

H1 Axial Piston Pump, Size 147/165, Single Technical Information Notes


Notes

11063347 Rev BC Mar 2011

33

H1 Axial Piston Pump, Size 147/165, Single Technical Information Notes


Notes

34

11063347 Rev BC Mar 2011

H1 Axial Piston Pump, Size 147/165, Single Technical Information Notes


Notes

11063347 Rev BC Mar 2011

35

Products we o er: Bent Axis Motors Closed Circuit Axial Piston Pumps and Motors Displays Electrohydraulic Power Steering Electrohydraulics Hydraulic Power Steering Integrated Systems Joysticks and Control Handles Microcontrollers and Software Open Circuit Axial Piston Pumps Orbital Motors PLUS+1 GUIDE Proportional Valves Sensors Steering Transit Mixer Drives

Sauer-Danfoss is a global manufacturer and supplier of highquality hydraulic and electronic components. We specialize in providing state-of-the-art technology and solutions that excel in the harsh operating conditions of the mobile o -highway market. Building on our extensive applications expertise, we work closely with our customers to ensure exceptional performance for a broad range of o -highway vehicles. We help OEMs around the world speed up system development, reduce costs and bring vehicles to market faster. Sauer-Danfoss Your Strongest Partner in Mobile Hydraulics.

Go to www.sauer-danfoss.com for further product information.

Wherever o -highway vehicles are at work, so is Sauer-Danfoss. We o er expert worldwide support for our customers, ensuring the best possible solutions for outstanding performance. And with an extensive network of Global Service Partners, we also provide comprehensive global service for all of our components.

Please contact the Sauer-Danfoss representative nearest you.


Local address:

Members of the Sauer-Danfoss Group: Comatrol www.comatrol.com Schwarzmller-Inverter www.schwarzmueller-inverter.com Turolla www.turollaocg.com Hydro-Gear www.hydro-gear.com Sauer-Danfoss-Daikin www.sauer-danfoss-daikin.com

Sauer-Danfoss (US) Company 2800 East 13th Street Ames, IA 50010, USA Phone: +1 515 239 6000 Fax: +1 515 239 6618 Sauer-Danfoss GmbH & Co. OHG Postfach 2460, D-24531 Neumnster Krokamp 35, D-24539 Neumnster, Germany Phone: +49 4321 871 0 Fax: +49 4321 871 122

Sauer-Danfoss ApS DK-6430 Nordborg, Denmark Phone: +45 7488 4444 Fax: +45 7488 4400

Sauer-Danfoss-Daikin LTD. Shin-Osaka TERASAKI 3rd Bldg. 6F 1-5-28 Nishimiyahara, Yodogawa-ku Osaka 532-0004, Japan Phone: +81 6 6395 6066 Fax: +81 6 6395 8585

11063347 Rev BC Mar 2011

www.sauer-danfoss.com