CC205~MECHANIC OF STRUCTURE

EXPERIMENT 2(B)

TITLE : Bending Moment Variation for Various Loading Conditions

OBJECTIVES : This experiment examines how bending moment varies at the cut position of the beam for various loading conditions.

INTRODUCTION :

*Bending Moment

In a similar manner it can that if the Bending moments (BM) of the forces to the left of AA are clockwise then the bending moment of the forces to the right of AA must be anticlockwise. Bending Moment at AA is defined as the algebraic sum of the moments about the section of all forces acting on either side of the section Bending moments are considered positive when the moment on the left portion is clockwise and on the right anticlockwise. This is referred to as aging bending moment as it tends to make the beam concave upwards at AA. A negative bending moment is termed hogging.

JKA, POLITEKNIK SULTAN ABDUL HALIM MUADZAM SHAH

CC205~MECHANIC OF STRUCTURE

APPARATUS :

1) Digital Force Display

2) Load and Hanger

3) Rules

JKA, POLITEKNIK SULTAN ABDUL HALIM MUADZAM SHAH

CC205~MECHANIC OF STRUCTURE

THEORY :

We know that if a body or object of any sort is stationary, then the forces on it balance, as follows: (1) Vertical equilibrium (total force up = total force down) (2) Horizontal equilibrium (total force right = total force left) (3) Moment equilibrium (total clockwise moment = total anticlockwise moment). We will use the statement: The Bending Moment at the cut is equal to the algebraic sum of the moments caused by the forces acting to the left or right of the cut.

JKA, POLITEKNIK SULTAN ABDUL HALIM MUADZAM SHAH

CC205~MECHANIC OF STRUCTURE

PROCEDUR:

(i)

Check the Digital Force Display meter reads zero with no load.

(ii)Measure the first position

JKA, POLITEKNIK SULTAN ABDUL HALIM MUADZAM SHAH

CC205~MECHANIC OF STRUCTURE

(iii) Carefully load the beam with the hangers in the positions shown in Figure 1, using the loads indicated in table 2a. cut 140mm W1 RA 300mm RB

W1 = 3.92 N (400g) Figure 1 : Force diagram (iii) Record the Digital Force Display reading as in a figure 2 and figure 3. (iv) Repeat the procedure with the beam loaded as in figure (v) Convert the mass into a load (in N refer table 1a)

140mm RA 260mm W1 W2 W1 = 1.96 N (200g) W2 = 3.92 N (400g)

cut RB

Figure 2 : Force diagram 240mm 400mm RA W1 = 4.91 N (500g) W2 = 3.92 N (400g) Figure 3 : Force diagram W1 W2 RB cut

JKA, POLITEKNIK SULTAN ABDUL HALIM MUADZAM SHAH

CC205~MECHANIC OF STRUCTURE

Result : Figure W1 (N) W2 (N) Experimental bending moment (Nm) 1 2 3 RA (N) RB (N) Theoretical bending moment (Nm)

CALCULATION : Calculation for Theoretical bending moment (Nm) W : Load (N), a : the distance to the load (not the cut) (m) -3 Load 3.92 Load 5.88 Load 8.83
( ) ( )

Calculation for RA and RB : Figure 1 : Figure 2 : Figure 3 :

DISCUSSION :
JKA, POLITEKNIK SULTAN ABDUL HALIM MUADZAM SHAH

CC205~MECHANIC OF STRUCTURE

1. Comment on how the result of the experiments compare with those calculated using the theory.

CONCLUSION :

REFERENCE :