8 or 11-pin socket mounting 2 or 3 change over contacts Long life (minimun 100.000 electrical operations) at 10 A 250 VAC /30 VDC Switching capacity 12 A (5x104 cycles) AC coils 6 to 230 VAC DC coils 6 to 110 VDC Matched sockets available Standard with LED, Push with arm and Flag IP 40 Conform to CE low voltage directive IMQ, UL, TV, CSA approved RCP
Product Description
The RCP relay can be used for a wide range of industrial applications. Available in 2 or 3 changeover contact configuration, Octal or Undecal version.
Ordering Key
Type No. of pins Contact code Rated coil voltage DC / AC
RCP 8 002 24 DC
Type Selection
Contact configuration 2 change over contacts 3 change over contacts (DPDT {2-form C}) (3PDT {3-form C}) Contact rating 10 A 10 A Contact code 002 003
Coil Characteristics, DC
At 20C Nominal voltage VDC 6 12 24 48 60 100 110 Pick-up voltage VDC 4.8 9.6 19.2 38.4 45.0 80.0 88.0 Drop-out voltage VDC 0.6 1.2 2.4 4.8 6.0 10.0 11.0 Pick-up voltage VDC 5.2 10.3 20.7 41.4 48.6 86.4 95.0 At 40C Drop-out voltage VDC 0.6 1.3 2.6 5.1 6.4 10.8 11.8 Coil resistance 23.5 95.0 430.0 1630.0 3000.0 6800.0 6800.0 10% 10% 10% 15% 15% 15% 15%
Coil Characteristics, AC
At 20C Nominal voltage VAC 6 12 24 48 115/120 230 Pick-up voltage VAC 4.8 9.6 19.2 38.4 88.0 176.0 Drop-out voltage VAC 1.8 3.6 7.2 14.4 36.0 72.0 Pick-up voltage VAC 5.2 10.3 20.7 41.4 95.0 190.0 At 40C Drop-out voltage VAC 1.9 3.8 7.7 15.5 38.8 77.7 Coil resistance 40.0 160.0 650.0 2600.0 11000.0 11000.0 10% 10% 10% 15% 15% 15%
16
Contact Characteristics
Arrangement Contact rating (with resistive load) UL rating Usually rating Max. rating Material (1x105 ops) (5x104 ops) 002 / 003 10 A - 250 VAC / 30 VDC 10 A - 250 VAC / 30VDC 1/3 HP at 240 VAC 10 A - 250 VAC / 30 VDC 12 A - 250 VAC / 30 VDC Silver alloy Current Max. switching current Initial contact resistance Max. switch. voltage Max. switch. power Life Electrical life Mechanical life 10 A 50 m (at 1 A 6 VDC) 250 VAC / 30 VDC 2500 VA / 300 W 1x105 ops 1x107 ops
Insulation
Test Voltage (1 min.) Between coil and contacts Between open contacts Contact/Contact Initial insulation resistance 3750 VAC Vr.m.s 750 VAC Vr.m.s 1250 VA Vr.m.s 500 M - 500 VAC Insulation according to EN61810-5 Rated insulation voltage Impulsive insulation voltage Pollution degree Overvoltage category 250 V 3.6 KV 2 III
General Data
Nominal coil power Operating time (At nominal voltage) Release time (At nominal voltage) Temperature rise (At nominal voltage) Ambient temperature 1.5 W / 2.5 VA 30 ms max. 20 ms max. -40 C to +55 C +50 C Vibration resistance Shock resistance Funktional Destructive Humidity Termination Construction Weight 10 to 55 Hz 1.5 mm 100 m/s2 /10 g 500 m/s2 /50 g 98%, +40C% Octal/Undecal-type plug Dust cover ~ 85 g
Dimensions
RCP8 . . . .
Wiring Diagrams
RCP8 . . . .
35.5
56
13 8
4 3 2 1
5 6 7
35.5
6 7 8
3 2 1 8
RCP11 . . . .
RCP11 . . . .
35.5
6 5 4 3 2 1 11 7
56
13 8
7 8 9
8 9 10
35.5
4 3 2 1 11
10
17
Diagrams
1 Coil Operating Range
1.1 1.0 0.9 0.8 0.7 0.6 0 10 +10 +20 +30 +40 +50 +60
Ambient temperature (C)
2 Electrical life
10
DC inductive load L 28 VDC = 40ms
R
0 1 2 3 4 5 6 7 8 9 10 11 12
Switching Current (A) 3 Max. DC load breaking capacity Rated Current (A)
0 1 2 3 4 5 6 7 8 9 10 11 12
Switching Current (A)
10
AC inductive load COS = 0,4
10
Rated Current (A)
5 1 0.5 0.1
DC inductive load L = 40ms
R
5 1 0.5 0.1
AC Resistive load
DC Resistive load
Approvals
U.S.A. CANADA GERMANY ITALY
18