Anda di halaman 1dari 12

Cell Algorithm Switch(UCELLALGOSWITCH)

Function Use this command to modify the algorithm switch of a cell to enable or disable the cell algorithm. Parameter ID CellId Parameter Name Cell ID Parameter Description Meaning: Uniquely identifying a cell. For detailed information of this parameter, refer to 3GPP TS 25.401. GUI Value Range: 0~65535 Actual Value Range: 0~65535 Unit: None Default Value: None Recommended Value: None NBMCacAlgoSwitch Cell CAC algorithm switch Meaning: The above values of the algorithms represent the following information: CRD_ADCTRL: Control NodeB Credit admission control algorithm Only when NODEB_CREDIT_CAC_SWITCH which is set by the SET UCACALGOSWITCH command and this switch are on,the NodeB Credit admission control algorithm is valid. HSDPA_UU_ADCTRL: Control HSDPA UU Load admission control algorithm HSDPA_GBP_MEAS: Control HSDPA HS-DSCH Required Power measurement HSDPA_PBR_MEAS: Control HSDPA HS-DSCH Provided Bit Rate measurement

Parameter ID

Parameter Name

Parameter Description HSUPA_UU_ADCTRL: Control HSUPA UU Load admission control algorithm MBMS_UU_ADCTRL: Control MBMS UU Load admission control algorithm DOFFC: Default DPCH offset configuration algorithm HSUPA_PBR_MEAS: Control HSUPA Provided Bit Rate measurement HSUPA_EDCH_RSEPS_MEAS: Control HSUPA Provided Received Scheduled EDCH Power Share measurement. EMC_UU_ADCTRL: Control power admission for emergency user FACH_UU_ADCTRL: Control admission for user over FACH channels If CRD_ADCTRL,HSDPA_UU_ADCTRL,HSDPA_GBP_MEAS,HSDPA_PBR_MEAS,HSUPA _UU_ADCTRL, MBMS_UU_ADCTRL, DOFFC, HSUPA_PBR_MEAS ,HSUPA_EDCH_RSEPS_MEAS, EMC_UU_ADCTRL,and FACH_UU_ADCTRL are selected, the corresponding algorithms will be enabled; otherwise, disabled. GUI Value Range: CRD_ADCTRL(Credit Admission Control Algorithm), HSDPA_UU_ADCTRL(HSDPA UU Load Admission Control Algorithm), HSUPA_UU_ADCTRL(HSUPA UU Load Admission Control Algorithm), MBMS_UU_ADCTRL(MBMS UU Load Admission Control Algorithm), HSDPA_GBP_MEAS(HSDPA GBP Meas Algorithm), HSDPA_PBR_MEAS(HSDPA PBR Meas Algorithm), DOFFC(DPCH Offset Configuration Algorithm), HSUPA_PBR_MEAS(HSUPA PBR Meas Algorithm), HSUPA_EDCH_RSEPS_MEAS(HSUPA EDCH RSEPS Meas Algorithm), EMC_UU_ADCTRL(emergency call power admission), FACH_UU_ADCTRL(FACH power cac switch) Actual Value Range: CRD_ADCTRL, HSDPA_UU_ADCTRL, HSUPA_UU_ADCTRL, MBMS_UU_ADCTRL, HSDPA_GBP_MEAS, HSDPA_PBR_MEAS, DOFFC, HSUPA_PBR_MEAS, HSUPA_EDCH_RSEPS_MEAS, EMC_UU_ADCTRL,

Parameter ID

Parameter Name FACH_UU_ADCTRL Unit: None Default Value: None Recommended Value: None

Parameter Description

NBMUlCacAlgoSelSwitch

Uplink CAC algorithm switch

Meaning: The algorithms with the above values represent are as follow: ALGORITHM_OFF: Disable uplink call admission control algorithm. ALGORITHM_FIRST: The load factor prediction algorithm will be used in uplink CAC. ALGORITHM_SECOND: The equivalent user number algorithm will be used in uplink CAC. ALGORITHM_THIRD: The loose call admission control algorithm will be used in uplink CAC. GUI Value Range: ALGORITHM_OFF, ALGORITHM_FIRST, ALGORITHM_SECOND, ALGORITHM_THIRD Actual Value Range: ALGORITHM_OFF, ALGORITHM_FIRST, ALGORITHM_SECOND, ALGORITHM_THIRD Unit: None Default Value: None Recommended Value: None

NBMDlCacAlgoSelSwitch

Downlink CAC algorithm switch

Meaning: The algorithms with the above values represent are as follow: ALGORITHM_OFF: Disable downlink call admission control algorithm.

Parameter ID

Parameter Name

Parameter Description ALGORITHM_FIRST: The load factor prediction algorithm will be used in downlink CAC. ALGORITHM_SECOND: The equivalent user number algorithm will be used in downlink CAC. ALGORITHM_THIRD: The loose call admission control algorithm will be used in downlink CAC. GUI Value Range: ALGORITHM_OFF, ALGORITHM_FIRST, ALGORITHM_SECOND, ALGORITHM_THIRD Actual Value Range: ALGORITHM_OFF, ALGORITHM_FIRST, ALGORITHM_SECOND, ALGORITHM_THIRD Unit: None Default Value: None Recommended Value: None

NBMLdcAlgoSwitch

Cell LDC algorithm switch

Meaning: The algorithms with the above values represent are as follow: INTRA_FREQUENCY_LDB: Intra-frequency load balance algorithm. It is also named cell breathing algorithm.Based on the cell load, this algorithm changes the pilot power of the cell to control the load between intra-frequency cells. PUC: Potential user control algorithm. Based on the cell load, this algorithm changes the selection/reselection parameters of a cell to lead the UE to a lighter loaded cell. UL_UU_OLC: UL UU overload congestion control algorithm. When the cell is overloaded in UL, this algorithm reduces the cell load in UL by quick TF restriction or UE release. DL_UU_OLC: DL UU overload congestion control algorithm. When the cell is overloaded in DL, this algorithm reduces the cell load in DL by quick TF restriction or UE release. UL_UU_LDR: UL UU load reshuffling algorithm. When the cell is heavily loaded in UL, this

Parameter ID

Parameter Name

Parameter Description algorithm reduces the cell load in UL by using inter-frequency load handover, BE service rate reduction, uncontrollable real-time service QoS renegotiation, CS should be inter-RAT, PS should be inter-RAT handover, CS should not be inter-RATand, PS should not be interRAT handover and AMR service rate reduction. DL_UU_LDR: DL UU load reshuffling algorithm. When the cell is heavily loaded in DL, this algorithm reduces the cell load in DL by using inter-frequency load handover, BE service rate reduction, uncontrollable real-time service QoS renegotiation, CS should be inter-RAT, PS should be inter-RAT handover, CS should not be inter-RATand, PS should not be interRAT handover, AMR service rate reduction and MBMS service power decrease. OLC_EVENTMEAS: Control OLC event measurement. This algorithm starts the OLC event measurement. CELL_CODE_LDR: Code reshuffling algorithm. When the cell CODE is heavily loaded, this algorithm reduces the cell CODE load by using BE service rate reduction and code tree reshuffling. CELL_CREDIT_LDR:Credit reshuffling algorithm. When the cell credit is heavily loaded, this algorithm reduces the credit load of the cell by using BE service rate reduction, uncontrollable real-time service QoS renegotiation, CS should be inter-RAT, PS should be inter-RAT handover, CS should not be inter-RATand and PS should not be inter-RAT handover. If INTRA_FREQUENCY_LDB, PUC, ULOLC, DLOLC, ULLDR, UDLLDR, OLC_EVENTMEAS, CELL_CODE_LDR and CELL_CREDIT_LDR are selected, the corresponding algorithms will be enabled; otherwise, disabled. GUI Value Range: INTRA_FREQUENCY_LDB(Intra Frequency LDB Algorithm), PUC(Potential User Control Algorithm), UL_UU_LDR(Uplink UU LDR Algorithm), DL_UU_LDR(Downlink UU LDR Algorithm), UL_UU_OLC(Uplink UU OLC Algorithm), DL_UU_OLC(Downlink UU OLC Algorithm), OLC_EVENTMEAS(OLC Event Meas Algorithm), CELL_CODE_LDR(Code LDR Algorithm), CELL_CREDIT_LDR(Credit LDR Algorithm) Actual Value Range: INTRA_FREQUENCY_LDB, PUC, UL_UU_LDR, DL_UU_LDR,

Parameter ID

Parameter Name

Parameter Description UL_UU_OLC, DL_UU_OLC, OLC_EVENTMEAS, CELL_CODE_LDR, CELL_CREDIT_LDR Unit: None Default Value: None Recommended Value: None

NBMMachsResetAlgoSel Switch

Mac-hs Reset algorithm switch

Meaning: The algorithms with the above values represent are as follow: ALGORITHM_REQUIRED: Always reset the mac-hs no matter the cells in question are in the same NodeB or not. ALGORITHM_DEPEND_ON_LCG: Reset the mac-hs only when the cells in question are in the different local cell group. GUI Value Range: ALGORITHM_REQUIRED, ALGORITHM_DEPEND_ON_LCG Actual Value Range: ALGORITHM_REQUIRED, ALGORITHM_DEPEND_ON_LCG Unit: None Default Value: None Recommended Value: ALGORITHM_DEPEND_ON_LCG

HspaPlusSwitch

Cell Hspa Plus function switch

Meaning: If 64QAM,MIMO,E_FACH,DTX_DRX,HS_SCCH_LESS_OPERATION and L2ENHANCED are selected, the corresponding function will be enabled; otherwise, disabled. GUI Value Range: 64QAM(Cell 64QAM Function Switch), MIMO(Cell MIMO Function Switch), E_FACH(Cell E_FACH Function Switch), DTX_DRX(Cell DTX_DRX Function Switch), HS_SCCH_LESS_OPERATION(Cell HS_SCCH LESS OPERATION Function Switch), L2ENHANCED(Cell L2ENHANCED Function Switch)

Parameter ID

Parameter Name

Parameter Description Actual Value Range: 64QAM, MIMO, E_FACH, DTX_DRX, HS_SCCH_LESS_OPERATION, L2ENHANCED Unit: None Default Value: None Recommended Value: None

HspaEnhSwitch

Cell Hspa Enhanced function switch

Meaning: If E_F_DPCH are selected, the corresponding function will be enabled; otherwise, disabled. GUI Value Range: E_F_DPCH_OFF, E_F_DPCH_ON Actual Value Range: E_F_DPCH_OFF, E_F_DPCH_ON Unit: None Default Value: None Recommended Value: E_F_DPCH_OFF

CellCapacityAutoHandleS Cell Capability Auto witch Handle Switch

Meaning: The algorithms with the above values represent are as follow: TX_DIVERSITY_ON_TO_OFF:When TX Diversity is on to off,the algorithms of cell capacity auto handle is open. TX_DIVERSITY_OFF_TO_ON:When TX Diversity is off to on,the algorithms of cell capacity auto handle is open. GUI Value Range: TX_DIVERSITY_ON_TO_OFF(TX diversity capability is on to off), TX_DIVERSITY_OFF_TO_ON(TX diversity capability is off to on) Actual Value Range: TX_DIVERSITY_ON_TO_OFF, TX_DIVERSITY_OFF_TO_ON

Parameter ID

Parameter Name Unit: None Default Value: None Recommended Value: None

Parameter Description

NbmLdcBHOUeSelSwitch BHO Select User algorithm switch

Meaning: The algorithms with the above values represent are as follow: NBM_LDC_ALL_UE: When BHO select user occurs, no need to consider whether target cell support Ue. NBM_LDC_MATCH_UE_ONLY: When BHO select user occurs, only consider Ues supported by target cell. NBM_LDC_MATCH_UE_FIRST: When BHO select user occurs, first consider Ues supported by target cell. GUI Value Range: NBM_LDC_ALL_UE(Select all users), NBM_LDC_MATCH_UE_ONLY(Select users match target cell support only), NBM_LDC_MATCH_UE_FIRST(Select users match target cell support first) Actual Value Range: NBM_LDC_ALL_UE, NBM_LDC_MATCH_UE_ONLY, NBM_LDC_MATCH_UE_FIRST Unit: None Default Value: None Recommended Value: NBM_LDC_MATCH_UE_ONLY

RsvdPara1

Reserved parameter 1

Meaning: The algorithms with the above values represent are as follow: RSVDBIT1: Control RTWP Anti-interfence algorithm RSVDBIT2~RSVDBIT16:Reserved Switch If RSVDBIT1 is selected, the corresponding algorithms will be enabled; otherwise, disabled. GUI Value Range: RSVDBIT1(Reserved Switch 1), RSVDBIT2(Reserved Switch 2), RSVDBIT3(Reserved Switch 3), RSVDBIT4(Reserved Switch 4), RSVDBIT5(Reserved

Parameter ID

Parameter Name

Parameter Description Switch 5), RSVDBIT6(Reserved Switch 6), RSVDBIT7(Reserved Switch 7), RSVDBIT8(Reserved Switch 8), RSVDBIT9(Reserved Switch 9), RSVDBIT10(Reserved Switch 10), RSVDBIT11(Reserved Switch 11), RSVDBIT12(Reserved Switch 12), RSVDBIT13(Reserved Switch 13), RSVDBIT14(Reserved Switch 14), RSVDBIT15(Reserved Switch 15), RSVDBIT16(Reserved Switch 16) Actual Value Range: RSVDBIT1, RSVDBIT2, RSVDBIT3, RSVDBIT4, RSVDBIT5, RSVDBIT6, RSVDBIT7, RSVDBIT8, RSVDBIT9, RSVDBIT10, RSVDBIT11, RSVDBIT12, RSVDBIT13, RSVDBIT14, RSVDBIT15, RSVDBIT16 Unit: None Default Value: None Recommended Value: None

RsvdPara2

Reserved parameter 2

Meaning: Reserved parameter 2 GUI Value Range: 0~4294967295 Actual Value Range: 0~4294967295 Unit: None Default Value: None Recommended Value: 0

RsvdPara3

Reserved parameter 3

Meaning: Reserved parameter 3 GUI Value Range: 0~4294967295 Actual Value Range: 0~4294967295 Unit: None

Parameter ID

Parameter Name Default Value: None Recommended Value: 0

Parameter Description

Example
Modify the algorithm switch of a cell. MOD UCELLALGOSWITCH: CELLID=1, NBMULCACALGOSELSWITCH=ALGORITHM_OFF, NBMDLCACALGOSELSWITCH=ALGORITHM_OFF;


Cell CAC algorithm switch Credit Admission Control Algorithm:ON = HSDPA UU Load Admission Control Algorithm:OFF = HSUPA UU Load Admission Control Algorithm:OFF = MBMS UU Load Admission Control Algorithm:OFF = HSDPA GBP Meas Algorithm:OFF = HSDPA PBR Meas Algorithm:OFF = DPCH Offset Configuration Algorithm:ON = HSUPA PBR Meas Algorithm:OFF = HSUPA EDCH RSEPS Meas Algorithm:OFF = emergency call power admission:ON = FACH power cac switch:OFF Uplink CAC algorithm switch = ALGORITHM_SECOND Downlink CAC algorithm switch = ALGORITHM_FIRST =

Cell LDC algorithm switch


= = = = = = = = = = =

Intra Frequency LDB Algorithm:OFF

Mac-hs Reset algorithm switch Cell Hspa Plus function switch

Potential User Control Algorithm:OFF Uplink UU LDR Algorithm:OFF Downlink UU LDR Algorithm:OFF Uplink UU OLC Algorithm:OFF Downlink UU OLC Algorithm:OFF OLC Event Meas Algorithm:OFF Code LDR Algorithm:OFF Credit LDR Algorithm:OFF ALGORITHM_DEPEND_ON_LCG Cell 64QAM Function Switch:OFF Cell MIMO Function Switch:OFF

Cell Hspa Enhanced function switch Cell Capability Auto Handle Switch BHO Select User algorithm switch Reserved parameter 1

Reserved parameter 2 Reserved parameter 3 (Number of results = 1)

= = = = = = = = = = = = = = = = = = = = = = = = = =

Cell E_FACH Function Switch:OFF Cell DTX_DRX Function Switch:OFF Cell HS_SCCH LESS OPERATION Function Switch:OFF Cell L2ENHANCED Function Switch:OFF E_F_DPCH_OFF TX diversity capability is on to off:OFF TX diversity capability is off to on:OFF Select users match target cell support only Reserved Switch 1:OFF Reserved Switch 2:OFF Reserved Switch 3:OFF Reserved Switch 4:OFF Reserved Switch 5:OFF Reserved Switch 6:OFF Reserved Switch 7:OFF Reserved Switch 8:OFF Reserved Switch 9:OFF Reserved Switch 10:OFF Reserved Switch 11:OFF Reserved Switch 12:OFF Reserved Switch 13:OFF Reserved Switch 14:OFF Reserved Switch 15:OFF Reserved Switch 16:OFF 0 0

Anda mungkin juga menyukai