CYLINDRICAL CASED AXIAL FLOW FANS

THGT Series

F400-120

F300-120

F200-120

Short casing

Range of adjustable pitch aerofoil blade,


cased axial flow fans designed for smoke
extract in fire conditions and certified
F400-120, F300-120 and F200-120
(CE marked).
Casings formed from rolled sheet steel with
a corrosion resistant hot dipped galvanised
finish for all models.
All models F400-120 except 2 poles
incorporate separate high grade diecast aluminium blades locked within an
aluminium injected hub (diameters from 400
to 630) or a pressed sheet steel hub.
(diameters from 710 to 1250).
F300-120 and F200-120 models incorporate
an aluminium injected hub (diameters from
400 to 800) or a pressed sheet steel hub.
(diameters from 900 to 1250).
2 POLES F400-120 model with aluminium
impeller / hub formed from a one piece
casting.
All models are available in both short and
long casing versions except 2 poles F400-120
model only supplied with long casing.
Long casing versions (L) include an
external terminal box.
Suitable for horizontal or vertical
mounting installation.
Motors
Available, depending upon the model:
- with three phase motors in 2, 4 or 6 poles.
- with three phase two speed motors, 2/4,
4/8 or 6/12 poles.
F400-120 motors are IP55, class H insulation.
F300-120 motors are IP55, class H insulation.
F200-120 motors are IP55, class F insulation.
Electrical supplies:
Three phase 230/400V-50Hz up to 3 kW.
Three phase 400V-50Hz, for higher
power motors and two speed motors.
(See characteristics chart).
Motors suitable for inverter control.
In emergeny operation, direct protected
power supply.
On demand: 4/6 poles 2-speed motors.
Specic applications

Long casing
(L version)

F400-120

F300-120

F200-120

Ofcially
approved to
EN12101-3
standard.
Certicate n
0370-CPD-0348

ON REQUEST
Ofcially
approved to
EN12101-3
standard.
Certicate n
0370-CPD-0742

ON REQUEST
Ofcially
approved to
EN12101-3
standard.
Certicate n
0370-CPD-0349

Highly versatile range due to different number of available blades and adjustable pitch angles

Car Parks

Industrial
kitchens

Impellers with 3, 5, 6, 7 or 9 blades with adjustable pitch angles, allowing the most optimum selection to achieve with every kind of
installation requirements.

Cylindrical cased axial ow fans THGT

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series - 2 POLES F400-120

F400-120

Cased axial fan rated F400-120 for smoke


extract in fire condition. Long casing formed
from rolled sheet steel with a corrosion
resistant hot dipped galvanised finish.
Aluminium Impeller / hub formed from a
one piece casting, dinamically balanced.
Motors
Available, depending upon the model:
- with three phase motors in 2 poles.
- with three phase two speed motors in
2/4 poles.
F400-120 motors are IP55 - Class H
insulation and external terminal box,
situated out of the airflow.
Electrical supplies:
Three phase 230/400V-50 Hz up to 3 kW.
Three phase 400V-50Hz, for higher
power motors and two speed motors.
Specic applications

F400-120
Ofcially
approved
to EN12101-3
standard.
Certicate n
0370-CPD-0741

Terminal box in option


External terminal box for
ease of connection.

www.solerpalau.com

Car Parks

Industrial
kitchens

Impeller dinamically
balanced
Alluminium impeller
manufactured from one
piece casting. Dinamically
balanced, according to ISO 1940
standard, giving vibration free
operation.

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series

Motor approved S1 and S2


F400-120, F300-120 or
F200-120 certied motors
approved for running
continuously (S1) or for
emergency operation (S2).

Corrosion resistance
Casings formed from rolled
sheet steel with a corrosion
resistant hot dipped
galvanised nish.

Impeller dynamically balanced


According to ISO 1940
standard, providing vibration
free operation.

Wide blade design higher pressure


Wide blade design to ensure the highest efcient airow performances.
F400-120: Conguration 1: from 400 to 630 models.
Conguration 2: from 710 to 1250 models.
F200-120 / F300-120: Conguration 1: from 400 to 800 models.
Conguration 2: from 900 to 1250 models.

Motor support
Manufactured from
electrowelded sheet steel.
F400-120 models from 400 to
800. F300-120 and F200-120
models from 400 to 800

Aerodynamic motor support


Aerodynamic design of the
motor support to optimise
airow performances models
from 900 to 1250.

Terminal box in option


External terminal box for
ease of connection (Long
casing version).

R EFERENCE
T

G
1

1234567-

8-

6
2

0
3

6
4

8
5

1,5 kW
8

Product range.
Number of poles.
Diameters.
Number of blades.
Blade pitch angle.
Airflow direction: B (Impeller-Motor) / A (Motor-Impeller).
Blank: with short casing without external terminal box.
K: with short casing with external terminal box.
L: with external terminal box.
LP: without external terminal box and with inspection box.
Motor power.

Cylindrical cased axial ow fans THGT

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
MOTOR POWERS (kW) FOR THGT PRODUCT RANGE
2 POLES
1
4 POLES
SPEED
6 POLES
MOTORS
F200-120

0,55

0,75

1,1

1,5

2,2

5,5

7,5

11

15

18,5

1,1

1,5

2,2

5,5

7,5

11

15

18,5

22

1,1

1,5

2,2

5,5

7,5

11

15

18,5

22

2,2/0,45

3/0,6

4,5/1

6,2/1,3

8,3/1,7

12/3

16/3,2

2,3/0,5

3/0,65

4/0,75

6,8/1,4

8,4/2,05 10,5/2,2 15,5/2,7

1,1/0,25 1,5/0,33
2/4 POLES
2
4/8 POLES 0,55/0,13 0,75/0,12 1,1/0,26 1,7/0,35
SPEED
0,75/0,15 1,3/0,2 1,5/0,25
6/12 POLES
2 POLES
1
4 POLES
SPEED
6 POLES
MOTORS
F300-120
2/4 POLES
2
4/8 POLES
SPEED
6/12 POLES
2 POLES
1
4 POLES
SPEED
6 POLES
MOTORS
F400-120
2/4 POLES
2
4/8 POLES
SPEED
6/12 POLES

0,55

0,55/0,09

0,55

0,75

2,2/0,37 3/0,55

4/0,65 5,5/1

7,5/1,3

11/1,8

37

22/4,4 33/8 42/10

15/2,5 18,5/3 25/4,5

1,1

1,5

2,2

5,5

7,5

11

15

1,1

1,5

2,2

5,5

7,5

11

15

18,5
18,5

22

1,1

1,5

2,2

5,5

7,5

11

15

18,5

22

1,1/0,25

1,5/0,35

2,2/0,6

3,1/0,8

4,4/1,1

6/1,5

8/2

12/3

16/4

0,75/0,12

1,1/0,18

1,5/0,25

2,2/0,37

3/0,55

4/0,75

5,5/1,1

7,5/1,5

11/3

17/4,3

20/5

28/6,5

0,75/0,12

1,1/0,18

1,5/0,25

2,2/0,37

3/0,55

4/0,65

6/1,2

7,5/1,5

12/2,4

17/4,3

20/5

28/6,5

1,1

1,5

2,2

5,5

7,5

11

15

1,1

1,5

2,2

5,5

7,5

11

15

18,5

22

1,1

1,5

2,2

5,5

7,5

11

15

18,5

22

0,75

30

1,1/0,25

1,5/0,37

2,2/0,5

3,1/0,8

4,4/1,1

6/1,5

8/2

12/3

16/4

0,55/0,09

0,75/0,12

1,1/0,18

1,5/0,25

2,2/0,37

3/0,55

4/0,75

5,5/1,1

7,5/1,5

11/3

17/4,3

20/5

28/6,5

0,55/0,09

0,75/0,12

1,1/0,18

1,5/0,25

2,2/0,37

3/0,55

4/0,65

6/1,2

7,5/1,5

12/2,4

17/4,3

20/5

28/6,5

30

37

45

35/8 37/9,2 44/11

30

37

45

30/8 37/9,2 44/11

* Note: For 2 speed motors, the powers may have small variations depending on the motor manufacturer.

TECHNICAL CHARACTERISTICS - MOTORS F400-120


Before installation check that the product electrical characteristics listed on the data plate label (voltage, power, frequency, etc.) match those of the intended
electrical supply.

THGT 1 SPEED MODELS


TECHNICAL CHARACTERISTICS - MOTORS F400 120 - 2 poles - 2950 rpm (one piece impeller)
Model

Motor
power
(kW)

230 V

400 V

THGT/2-400-6/27

1,1

5,5

3,1

48

THGT/2-400-6/32

1,5

8,0

4,6

53

THGT/2-450-6/22

1,5

5,5

3,1

48

THGT/2-450-6/27

2,2

THGT/2-450-6/32

THGT/2-500-6/17

1,5

Full load current


(A)

Weight
(Kg)

Model

Motor
power
(kW)

230 V

THGT/2-560-6/17

7,7

101

THGT/2-560-6/22

5,5

10,6

120

THGT/2-560-6/27

7,5

14,1

124

Full load current


(A)
400 V

8,0

4,6

53

THGT/2-630-6/17

7,5

14,1

133

10,3

5,9

48

THGT/2-630-6/22

7,5

14,1

141

THGT/2-630-6/27

11

17,3

175

5,5

3,1

63

THGT/2-630-6/32

15

20,4

181

THGT/2-500-6/22

10,3

5,9

73

THGT/2-500-6/27

7,7

88

We reserve right to supply different motors and hence data may change.

www.solerpalau.com

Weight
(Kg)

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
TECHNICAL CHARACTERISTICS - MOTORS F400 120 - 4 poles - 1450 rpm
Model

Motor
power
(kW)

THGT/4-400-6/- 0,55
THGT/4-450-6/- 0,55

0,55
0,55

Full load
current motor
(A)
V1

V2

2,2

1,3

2,2

1,3

Weight
(Kg)
Short
casing
38
39

Model

Long
casing
44
45

THGT/4-500-6/-0,55

0,55

2,2

1,3

45

51

THGT/4-500-6/-0,75

0,75

2,8

1,6

46

52

THGT/4-500-6/-1,1

1,1

4,2

2,4

51

57

Motor
power
(kW)

Full load
current motor
(A)

Weight
(Kg)

THGT/4-900-6/-3

10,7

6,2

Short
casing
104

THGT/4-900-6/-4

8,1

117

140

THGT/4-900-6/-5,5

5,5

10,5

130

153

THGT/4-900-6/-7,5

7,5

14,1

144

167

THGT/4-900-6/-11

11

21,2

171

194

THGT/4-900-9/-5,5

5,5

10,5

135

157

THGT/4-900-9/-7,5

7,5

14,1

149

171

THGT/4-900-9/-11

11

21,2

176

198

THGT/4-900-9/-15

15

28,7

204

226

V1

V2

Long
casing
127

THGT/4-560-6/-0,55

0,55

2,2

1,3

54

71

THGT/4-560-6/-0,75

0,75

2,8

1,6

55

72

THGT/4-560-6/-1,1

1,1

4,2

2,4

60

77

THGT/4-560-6/-1,5

1,5

5,7

3,3

61

78

THGT/4-1000-3/-3

10,7

6,2

111

132

THGT/4-560-6/-2,2

2,2

8,1

4,6

67

84

THGT/4-1000-3/-4

8,1

124

145

THGT/4-1000-3/-5,5

5,5

10,5

137

158

THGT/4-1000-3/-7,5

7,5

14,1

151

172

THGT/4-1000-3/-11

11

21,2

178

199

THGT/4-630-6/-0,75

0,75

2,8

1,6

59

74

THGT/4-630-6/-1,1

1,1

4,2

2,4

64

79

THGT/4-630-6/-1,5

1,5

5,7

3,3

65

80

THGT/4-630-6/-2,2

2,2

8,1

4,6

71

86

THGT/4-1000-6/-4

8,1

129

150

THGT/4-630-6/-3

10,7

6,2

74

89

THGT/4-1000-6/-5,5

5,5

10,5

142

163

THGT/4-1000-6/-7,5

7,5

14,1

156

177

THGT/4-1000-6/-11

11

21,2

183

204

THGT/4-1000-6/-15

15

28,7

211

232

THGT/4-1000-6/-18,5

18,5

35,1

259

280

THGT/4-710-5/-1,1

1,1

4,2

2,4

70

93

THGT/4-710-5/-1,5

1,5

5,7

3,3

71

94

THGT/4-710-5/-2,2

2,2

8,1

4,6

73

96

THGT/4-710-5/-3

10,7

6,2

76

99

THGT/4-710-5/-4

8,1

89

112

THGT/4-1000-9/-5,5

5,5

10,5

147

168

THGT/4-710-5/-5,5

5,5

10,5

102

125

THGT/4-1000-9/-7,5

7,5

14,1

161

182

THGT/4-1000-9/-11

11

21,2

188

209

THGT/4-1000-9/-15

15

28,7

216

237

THGT/4-1000-9/-18,5

18,5

35,1

264

285

THGT/4-1000-9/-22

22

40,5

265

286

THGT/4-710-7/-1,1

1,1

4,2

2,4

72

95

THGT/4-710-7/-1,5

1,5

5,7

3,3

73

96

THGT/4-710-7/-2,2

2,2

8,1

4,6

75

98

THGT/4-710-7/-3

10,7

6,2

78

101

THGT/4-710-7/-4

8,1

91

114

THGT/4-1250-3/-7,5

7,5

14,1

183

225

THGT/4-710-7/-5,5

5,5

10,5

104

127

THGT/4-1250-3/-11

11

21,2

210

252

THGT/4-1250-3/-15

15

28,7

238

280

THGT/4-1250-3/-18,5

18,5

35,1

286

328

THGT/4-1250-3/-22

22

40,5

287

329

THGT/4-1250-3/-30

30

56,2

347

389

THGT/4-800-3/-1,1

1,1

4,2

2,4

76

97

THGT/4-800-3/-1,5

1,5

5,7

3,3

77

98

THGT/4-800-3/-2,2

2,2

8,1

4,6

83

104

THGT/4-800-3/-3

10,7

6,2

86

107

THGT/4-800-3/-4

8,1

99

120

THGT/4-1250-6/-15

15

28,7

244

286

THGT/4-800-3/-5,5

5,5

10,5

112

133

THGT/4-1250-6/-18,5

18,5

35,1

292

334

THGT/4-1250-6/-22

22

40,5

293

335

THGT/4-1250-6/-30

30

56,2

353

395

THGT/4-1250-6/-37

37

66,6

454

496

THGT/4-1250-6/-45

45

80,7

499

541

THGT/4-800-6/-1,5

1,5

5,7

3,3

81

101

THGT/4-800-6/-2,2

2,2

8,1

4,6

87

107

THGT/4-800-6/-3

10,7

6,2

90

110

THGT/4-800-6/-4

8,1

103

123

THGT/4-800-6/-5,5

5,5

10,5

116

136

THGT/4-1250-9/-15

15

28,7

250

292

THGT/4-800-6/-7,5

7,5

14,1

130

150

THGT/4-1250-9/-18,5

18,5

35,1

298

340

THGT/4-1250-9/-22

22

40,5

299

341

THGT/4-1250-9/-30

30

56,2

359

401

THGT/4-1250-9/-37

37

66,6

460

502

THGT/4-1250-9/-45

45

80,7

505

547

THGT/4-800-9/-2,2

2,2

8,1

4,6

90

111

THGT/4-800-9/-3

10,7

6,2

93

114

THGT/4-800-9/-4

8,1

106

127

THGT/4-800-9/-5,5

5,5

10,5

119

140

THGT/4-800-9/-7,5

7,5

14,1

133

154

THGT/4-900-3/-2,2

2,2

8,1

4,6

96

119

THGT/4-900-3/-3

10,7

6,2

99

122

THGT/4-900-3/-4

8,1

112

135

THGT/4-900-3/-5,5

5,5

10,5

125

148

THGT/4-900-3/-7,5

7,5

14,1

139

162

We reserve right to supply different motors and hence data may change.

Cylindrical cased axial ow fans THGT

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
TECHNICAL CHARACTERISTICS - MOTORS F400 120 - 6 poles - 950 rpm
Model

THGT/6-560-6/- 0,55

Motor
power
(kW)

0,55

Full load
current
(A)
V1

V2

2,6

1,5

Model

Weight
(Kg)
Short
casing
54

Long
casing
71

Motor
power
(kW)

Full load
current
(A)
V1

V2
3,7

THGT/6-1000-3/- 1,5

1,5

6,5

THGT/6-1000-3/- 2,2

2,2

9,2

Weight
(Kg)
Short
casing
106

Long
casing
127

5,3

115

136

THGT/6-630-6/- 0,55

0,55

2,6

1,5

57

72

THGT/6-1000-3/- 3

12,7

7,3

139

160

THGT/6-630-6/- 0,75

0,75

3,4

2,0

62

77

THGT/6-1000-3/- 4

9,5

145

166

THGT/6-630-6/- 1,1

1,1

4,8

2,8

66

81
THGT/6-1000-6/-1,5

1,5

6,5

3,7

113

134

THGT/6-710-5/- 0,55

0,55

2,6

1,5

59

82

THGT/6-1000-6/-2,2

2,2

9,2

5,3

123

144

THGT/6-710-5/- 0,75

0,75

3,4

2,0

64

87

THGT/6-1000-6/-3

12,7

7,3

147

168

THGT/6-710-5/- 1,1

1,1

4,8

2,8

68

91

THGT/6-1000-6/-4

9,5

153

174

THGT/6-710-7/- 0,55

0,55

2,6

1,5

61

84

THGT/6-1000-6/-5,5

5,5

12,8

157

178

THGT/6-710-7/- 0,75

0,75

3,4

2,0

66

89

THGT/6-1000-9/- 2,2

2,2

9,2

5,3

126

147

THGT/6-710-7/- 1,1

1,1

4,8

2,8

70

93

THGT/6-1000-9/- 3

12,7

7,3

150

171

THGT/6-1000-9/- 4

9,5

156

177

THGT/6-800-3/- 0,75

0,75

3,4

2,0

73

94

THGT/6-800-3/- 1,1

1,1

4,8

2,8

77

98

THGT/6-800-3/- 1,5

1,5

6,5

3,7

82

103

THGT/6-800-6/- 0,75

0,75

3,4

2,0

76

96

THGT/6-800-6/- 1,1

1,1

4,8

2,8

80

100

THGT/6-800-6/- 1,5

1,5

6,5

3,7

86

106

THGT/6-800-6/- 2,2

2,2

9,2

5,3

95

115

THGT/6-800-9/- 0,75

0,75

3,4

2,0

79

100

THGT/6-800-9/- 1,1

1,1

4,8

2,8

83

104

THGT/6-800-9/- 1,5

1,5

6,5

3,7

89

110

THGT/6-800-9/- 2,2

2,2

THGT/6-800-9/- 3

THGT/6-900-3/- 1,5
THGT/6-900-3/- 2,2

9,2

5,3

98

119

12,7

7,3

122

143

1,5

6,4

3,7

95

118

2,2

9,2

5,3

104

127

THGT/6-1000-9/- 5,5

5,5

12,8

160

181

THGT/6-1000-9/- 7,5

7,5

15,0

204

225

THGT/6-1250-3/-2,2

2,2

9,2

5,3

151

193

THGT/6-1250-3/-3

12,7

7,3

175

217

THGT/6-1250-3/-4

9,5

181

223

THGT/6-1250-3/-5,5

5,5

12,8

185

227

THGT/6-1250-3/-7,5

7,5

15,0

229

271

THGT/6-1250-3/-11

11

22,0

249

291

THGT/6-1250-6/- 4

9,5

190

232

THGT/6-1250-6/- 5,5

5,5

12,8

194

236

THGT/6-1250-6/- 7,5

7,5

15,0

238

280

THGT/6-1250-6/- 11

11

22,0

258

300

THGT/6-1250-6/- 15

15

27,9

296

338

THGT/6-1250-9/-5,5

5,5

12,8

200

242

THGT/6-1250-9/-7,5

7,5

15,0

244

286

THGT/6-900-6/- 1,5

1,5

6,5

3,7

99

122

THGT/6-900-6/- 2,2

2,2

9,2

5,3

108

131

THGT/6-1250-9/-11

11

22,0

264

306

THGT/6-900-6/- 3

12,7

7,3

132

155

THGT/6-1250-9/-15

15

27,9

302

344

THGT/6-900-6/- 4

9,5

138

161

THGT/6-900-9/- 1,5

1,5

6,5

3,7

103

125

THGT/6-900-9/- 2,2

2,2

9,2

5,3

113

135

THGT/6-900-9/- 3

12,7

7,3

137

159

THGT/6-900-9/- 4

9,5

143

165

THGT/6-900-9/- 5,5

5,5

12,8

147

169

THGT/6-1250-9/-18,5

18,5

35,7

342

384

THGT/6-1250-9/-22

22

42,3

360

402

We reserve right to supply different motors and hence data may change.

www.solerpalau.com

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
TECHNICAL CHARACTERISTICS - MOTORS F400-120
Before installation check that the product electrical characteristics listed on the data plate label (voltage, power, frequency, etc.) match those of the intended
electrical supply.

THGT 2 SPEED MODELS


TECHNICAL CHARACTERISTICS - MOTORS F400 120 - 2/4 poles - 2950/1450 rpm (one piece impeller)
Model

Motor
power
(kW)

Full load current


motor
(A)

Weight
(Kg)

Model

Motor
power
(kW)

Full load current


motor
(A)

Weight
(Kg)

V1

V2

V1

V2

V1

V2

V1

V2

THGT/2/4-400-6/27

1,1

0,25

2,4

0,8

48

THGT/2/4-560-6/17

4,4

1,1

8,6

2,8

101

THGT/2/4-400-6/32

1,5

0,37

3,5

1,3

54

THGT/2/4-560-6/22

1,5

11,4

3,7

120

THGT/2/4-560-6/27

15,3

4,8

127

THGT/2/4-450-6/22

1,5

0,37

3,5

1,3

61

THGT/2/4-450-6/27

2,2

0,5

4,6

1,5

61

THGT/2/4-630-6/17

15,3

4,8

133

THGT/2/4-450-6/32

3,1

0,8

6,2

2,0

63

THGT/2/4-630-6/22

15,3

4,8

141

THGT/2/4-630-6/27

12

23,1

7,3

215

THGT/2/4-630-6/32

16

30,5

9,6

202

THGT/2/4-500-6/17

1,5

0,37

3,5

1,3

64

THGT/2/4-500-6/22

3,1

0,8

6,2

2,0

76

THGT/2/4-500-6/27

4,4

1,1

8,6

2,8

87

We reserve right to supply different motors and hence data may change.

TECHNICAL CHARACTERISTICS - MOTORS F400 120 - 4/8 poles - 1450/730 rpm


Model

Motor
power
(kW)

THGT/4/8-400-6/- 0,55/0,09

Full load
current motor
(A)

V1

V2

V1

V2

0,55

0,09

1,7

0,8

Weight
(Kg)
Short Long
casing casing
38
44

Model

Motor
power
(kW)
V1

V2

Full load
current motor
(A)
V1

V2

Weight
(Kg)
Short Long
casing casing
76
97

THGT/4/8-800-3/-1,1/0,18

1,1

0,18

2,7

1,2

THGT/4/8-800-3/-1,5/0,25

1,5

0,25

3,7

1,6

77

98

THGT/4/8-800-3/-2,2/0,37

2,2

0,37

4,7

1,7

83

104
107

THGT/4/8-450-6/- 0,55/0,09

0,55

0,09

1,7

0,8

39

45

THGT/4/8-800-3/-3/0,65

0,55

6,3

2,4

86

THGT/4/8-500-6/-0,55/0,09

0,55

0,09

1,7

0,8

45

51

THGT/4/8-800-3/-4/0,75

0,75

8,4

2,3

99

120

THGT/4/8-500-6/-0,75/0,12

0,75

0,12

1,9

0,8

46

52

THGT/4/8-800-3/-5,5/1,1

5,5

1,1

11,7

3,7

112

133

THGT/4/8-500-6/-1,1/0,18

1,1

0,18

2,7

1,2

51

57
THGT/4/8-800-6/-1,5/0,25

1,5

0,25

3,7

1,6

81

101

THGT/4/8-560-6/-0,55/0,09

0,55

0,09

1,7

0,8

54

71

THGT/4/8-800-6/-2,2/0,37

2,2

0,37

4,7

1,7

87

107

THGT/4/8-560-6/-0,75/0,12

0,75

0,12

1,9

0,8

55

72

THGT/4/8-800-6/-3/0,65

0,55

6,3

2,4

90

110

THGT/4/8-560-6/-1,1/0,18

1,1

0,18

2,7

1,2

60

77

THGT/4/8-800-6/-4/0,75

0,75

8,4

2,3

103

123

THGT/4/8-560-6/-1,5/0,25

1,5

0,25

3,7

1,6

61

78

THGT/4/8-800-6/-5,5/1,1

5,5

1,1

11,7

3,7

116

136

THGT/4/8-560-6/-2,2/0,37

2,2

0,37

4,7

1,7

67

84

THGT/4/8-800-6/-7,5/1,5

7,5

1,5

15,9

4,7

130

150

THGT/4/8-630-6/-0,75/0,12

0,75

0,12

1,9

0,8

59

74

THGT/4/8-800-9/-2,2/0,37

2,2

0,37

4,7

1,7

90

111

THGT/4/8-630-6/-1,1/0,18

1,1

0,18

2,7

1,2

64

79

THGT/4/8-800-9/-3/0,65

0,55

6,3

2,4

93

114

THGT/4/8-630-6/-1,5/0,25

1,5

0,25

3,7

1,6

65

80

THGT/4/8-800-9/-4/0,75

0,75

8,4

2,3

106

127

THGT/4/8-630-6/-2,2/0,37

2,2

0,37

4,7

1,7

71

86

THGT/4/8-800-9/-5,5/1,1

5,5

1,1

11,7

3,7

119

140

THGT/4/8-630-6/-3/0,65

0,55

6,3

2,4

74

89

THGT/4/8-800-9/-7,5/1,5

7,5

1,5

15,9

4,7

133

154

THGT/4/8-710-5/-1,1/0,18

1,1

0,18

2,7

1,2

70

93

THGT/4/8-900-3/-2,2/0,37

2,2

0,37

4,7

1,7

96

119

THGT/4/8-710-5/-1,5/0,25

1,5

0,25

3,7

1,6

71

94

THGT/4/8-900-3/-3/0,65

0,55

6,3

2,4

99

122

THGT/4/8-710-5/-2,2/0,37

2,2

0,37

4,7

1,7

73

96

THGT/4/8-900-3/-4/0,75

0,75

8,4

2,3

112

135

THGT/4/8-710-5/-3/0,65

0,55

6,3

2,4

76

99

THGT/4/8-900-3/-5,5/1,1

5,5

1,1

11,7

3,7

125

148

THGT/4/8-710-5/-4/0,75

0,75

8,4

2,3

89

112

THGT/4/8-900-3/-7,5/1,5

7,5

1,5

15,9

4,7

139

162

THGT/4/8-710-5/-5,5/1,1

5,5

1,1

11,7

3,7

102

125

THGT/4/8-710-7/-1,1/0,18

1,1

0,18

2,7

1,2

72

95

THGT/4/8-710-7/-1,5/0,25

1,5

0,25

3,7

1,6

73

96

THGT/4/8-710-7/-2,2/0,37

2,2

0,37

4,7

1,7

75

98

THGT/4/8-710-7/-3/0,65

0,55

6,3

2,4

78

101

THGT/4/8-710-7/-4/0,75

0,75

8,4

2,3

91

114

THGT/4/8-710-7/-5,5/1,1

5,5

1,1

11,7

3,7

104

127

We reserve right to supply different motors and hence data may change.

Cylindrical cased axial ow fans THGT

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
TECHNICAL CHARACTERISTICS - MOTORS F400 120 - 4/8 poles - 1450/730 rpm (continuation)
Model

Motor
power
(kW)

Full load
current motor
(A)

Weight
(Kg)
Short
Long
casing casing
104
127

Model

Motor
power
(kW)

V1

V2

V1

V2

THGT/4/8-900-6/-3/0,65

0,55

6,3

2,4

THGT/4/8-900-6/-4/0,75

0,75

8,4

2,3

117

140

THGT/4/8-1250-3/-11/3

11

THGT/4/8-900-6/-5,5/1,1

5,5

1,1

11,7

3,7

130

153

THGT/4/8-1250-3/-17/4,3

THGT/4/8-900-6/-7,5/1,5

7,5

1,5

15,9

4,7

144

167

THGT/4/8-900-6/-11/3

11

21,0

171

194

THGT/4/8-900-9/-5,5/1,1
THGT/4/8-900-9/-7,5/1,5

5,5

1,1

11,7

3,7

135

157

7,5

Full load
current motor
(A)

Weight
(Kg)
Short
Long
casing casing
183
225

V1

V2

V1

V2

7,5

1,5

15,9

4,7

21,0

7,0

210

252

17

4,3

33,4

12,7

238

280

THGT/4/8-1250-3/-20/5

20

38,6

14,1

286

328

THGT/4/8-1250-3/-28/6,5

28

6,5

52,0

18

287

329

THGT/4/8-1250-3/-35/8

35

67,3

21,8

347

389

THGT/4/8-1250-3/-7,5/1,5

1,5

15,9

4,7

149

171

THGT/4/8-1250-6/-17/4,3

17

4,3

33,4

12,7

244

286

THGT/4/8-900-9/-11/3

11

21,0

176

198

THGT/4/8-1250-6/-20/5

20

38,6

14,1

292

334

THGT/4/8-900-9/-15

17

4,3

33,4

12,7

204

226

THGT/4/8-1250-6/-28/6,5

28

6,5

52,0

18

293

335

THGT/4/8-1250-6/-35/8

35

67,3

21,8

353

395

THGT/4/8-1250-6/-37/9,2

37

9,2

74,2

25,4

454

496

THGT/4/8-1250-6/-44/11

44

80,2

27,2

499

541

THGT/4/8-1250-9/-17/4,3

17

4,3

33,4

12,7

250

292

THGT/4/8-1250-9/-20/5

20

38,6

14,1

298

340

28

6,5

52,0

18

299

341

THGT/4/8-1000-3/-3/0,55

0,55

6,3

2,4

111

132

THGT/4/8-1000-3/-4/0,75

0,75

8,4

2,3

124

145

THGT/4/8-1000-3/-5,5/1,1

5,5

1,1

11,7

3,7

137

158

7,5

1,5

15,9

4,7

151

172

21,0

178

199

THGT/4/8-1000-3/-7,5/1,5
THGT/4/8-1000-3/-11/3

11

11

THGT/4/8-1000-6/-4/0,75

0,75

8,4

2,3

129

150

THGT/4/8-1250-9/-28/6,5

THGT/4/8-1000-6/-5,5/1,1

5,5

1,1

11,7

3,7

142

163

THGT/4/8-1250-9/-35/8

35

67,3

21,8

359

401

THGT/4/8-1000-6/-7,5/1,5

7,5

1,5

15,9

4,7

156

177

THGT/4/8-1250-9/-37/9,2

37

9,2

74,2

25,4

460

502

THGT/4/8-1250-9/-44/11

44

80,2

27,2

505

547

THGT/4/8-1000-6/-11/3

11

21,0

7,0

183

204

THGT/4/8-1000-6/-17/4,3

17

4,3

33,4

12,7

211

232

THGT/4/8-1000-6/-20/5

20

38,6

14,1

259

280

THGT/4/8-1000-9/-5,5/1,1

5,5

1,1

11,7

3,7

147

168

THGT/4/8-1000-9/-7,5/1,5

7,5

1,5

15,9

4,7

161

182

THGT/4/8-1000-9/-11/3

11

21,0

188

209

THGT/4/8-1000-9/-17/4,3

17

4,3

33,4

12,7

216

237

THGT/4/8-1000-9/-20/5

20

38,6

14,1

264

285

THGT/4/8-1000-9/-28/6,5

28

6,5

52,0

18

265

286

11

We reserve right to supply different motors and hence data may change.

www.solerpalau.com

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
TECHNICAL CHARACTERISTICS - MOTORS F400 120 - 6/12 poles - 950/475 rpm
Model

Motor
power
(kW)

THGT/6/12-560-6/- 0,55/0,09

Full load
current motor
(A)

V1

V2

V1

V2

0,55

0,09

2,1

0,9

Model

Weight
(Kg)
Short
casing
54

Long
casing
71

Motor
power
(kW)

Full load
current motor
(A)

V1

V2

V1

THGT/6/12-1000-3/- 1,5/0,25

1,5

0,25

4,2

THGT/6/12-1000-3/- 2,2/0,37

2,2

0,37

5,7

Weight
(Kg)

1,7

Short
casing
106

Long
casing
127

V2

2,2

115

136

THGT/6/12-630-6/- 0,55/0,09

0,55

0,09

2,1

0,9

57

72

THGT/6/12-1000-3/- 3/0,55

0,55

8,9

3,8

139

160

THGT/6/12-630-6/- 0,75/0,12

0,75

0,12

2,3

1,0

62

77

THGT/6/12-1000-3/- 4/0,65

0,65

9,3

2,9

145

166

THGT/6/12-630-6/- 1,1/0,18

1,1

0,18

4,5

1,7

66

81
THGT/6/12-1000-6/-1,5/0,25

1,5

0,25

4,2

1,7

113

134

THGT/6/12-710-5/- 0,55/0,09

0,55

0,09

2,1

0,9

59

82

THGT/6/12-1000-6/-2,2/0,37

2,2

0,37

5,7

2,2

123

144

THGT/6/12-710-5/- 0,75/0,12

0,75

0,12

2,3

1,0

64

87

THGT/6/12-1000-6/-3/0,55

0,55

8,9

3,8

147

168

THGT/6/12-710-5/- 1,1/0,18

1,1

0,18

4,5

1,7

68

91

THGT/6/12-1000-6/-4/0,65

0,65

9,3

2,9

153

174

THGT/6/12-1000-6/-6/1,2

1,2

13,4

5,6

157

178

THGT/6/12-710-7/- 0,55/0,09

0,55

0,09

2,1

0,9

61

84

THGT/6/12-710-7/- 0,75/0,12

0,75

0,12

2,3

1,0

66

89

THGT/6/12-1000-9/- 2,2/0,37

2,2

0,37

5,7

2,2

126

147

THGT/6/12-710-7/- 1,1/0,18

1,1

0,18

4,5

1,7

70

93

THGT/6/12-1000-9/- 3/0,55

0,55

8,9

3,8

150

171

THGT/6/12-1000-9/- 4/0,65

0,65

9,3

2,9

156

177

THGT/6/12-1000-9/- 6/1,2

1,2

13,4

5,6

160

181

THGT/6/12-1000-9/- 7,5/1,5

7,5

1,5

16,4

6,5

204

225

THGT/6/12-1250-3/-2,2/0,37

2,2

0,37

5,7

2,2

151

193

THGT/6/12-1250-3/-3/0,55

0,55

8,9

3,8

175

217

THGT/6/12-1250-3/-4/0,65

0,65

9,3

2,9

181

223

THGT/6/12-1250-3/-6/1,2

1,2

13,4

5,6

185

227

THGT/6/12-1250-3/-7,5/1,5

7,5

1,5

16,4

6,5

229

271

THGT/6/12-1250-3/-12/2,4

12

2,4

23,4

8,1

249

291

THGT/6/12-1250-6/- 4/0,65

0,65

9,3

2,9

190

232

THGT/6/12-1250-6/- 6/1,2

1,2

13,4

5,6

194

236

THGT/6/12-1250-6/- 7,5/1,5

7,5

1,5

16,4

6,5

238

280

THGT/6/12-1250-6/- 12/2,4

12

2,4

23,4

8,1

258

300

THGT/6/12-1250-6/- 17/4,3

17

4,3

31,0

10,2

296

338

THGT/6/12-800-3/- 0,75/0,12

0,75

0,12

2,3

1,0

73

94

THGT/6/12-800-3/- 1,1/0,18

1,1

0,18

4,5

1,7

77

98

THGT/6/12-800-3/- 1,5/0,25

1,5

0,25

4,2

1,7

82

103

THGT/6/12-800-6/- 0,75/0,12

0,75

0,12

2,3

1,0

76

96

THGT/6/12-800-6/- 1,1/0,18

1,1

0,18

4,5

1,7

80

100

THGT/6/12-800-6/- 1,5/0,25

1,5

0,25

4,2

1,7

86

106

THGT/6/12-800-6/- 2,2/0,37

2,2

0,37

5,7

2,2

95

115

THGT/6/12-800-9/- 0,75/0,12

0,75

0,12

2,3

1,0

79

100

THGT/6/12-800-9/- 1,1/0,18

1,1

0,18

4,5

1,7

83

104

THGT/6/12-800-9/- 1,5/0,25

1,5

0,25

4,2

1,7

89

110

THGT/6/12-800-9/- 2,2/0,37

2,2

0,37

5,7

2,2

98

119

THGT/6/12-800-9/- 3/0,55

0,55

8,9

3,8

122

143

THGT/6/12-900-3/- 1,5/0,25

1,5

0,25

4,2

1,7

95

118

THGT/6/12-900-3/- 2,2/0,37

2,2

0,37

5,7

2,2

104

127

THGT/6/12-1250-9/-6/1,2

1,2

13,4

5,6

200

242

7,5

1,5

16,4

6,5

244

286

THGT/6/12-900-6/- 1,5/0,25

1,5

0,25

4,2

1,7

99

122

THGT/6/12-1250-9/-7,5/1,5

THGT/6/12-900-6/- 2,2/0,37

2,2

0,37

5,7

2,2

108

131

THGT/6/12-1250-9/-12/2,4

12

2,4

23,4

8,1

264

306

THGT/6/12-900-6/- 3/0,55

0,55

8,9

3,8

132

155

THGT/6/12-1250-9/-17/4,3

17

4,3

31,0

10,2

302

344

161

THGT/6/12-1250-9/-20/5

20

39,0

14,3

342

384

THGT/6/12-1250-9/-28/6,5

28

6,5

52,6

17,9

360

402

THGT/6/12-900-6/- 4/0,65
THGT/6/12-900-9/- 1,5/0,25

4
1,5

0,65
0,25

9,3
4,2

2,9
1,7

138
103

125

THGT/6/12-900-9/- 2,2/0,37

2,2

0,37

5,7

2,2

113

135

THGT/6/12-900-9/- 3/0,55

0,55

8,9

3,8

137

159

THGT/6/12-900-9/- 4/0,65

0,65

THGT/6/12-900-9/- 6/1,2

1,2

9,3

2,9

143

165

13,4

5,6

147

169

We reserve right to supply different motors and hence data may change.

Cylindrical cased axial ow fans THGT

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
TECHNICAL CHARACTERISTICS - MOTORS F300-120
Before installation check that the product electrical characteristics listed on the data plate label (voltage, power, frequency, etc.) match those of the intended
electrical supply.

THGT 1 SPEED MODELS


TECHNICAL CHARACTERISTICS - MOTORS F300 120 - 2 poles - 2950 rpm
Model

Motor
power
(kW)

Full load
current
(A)

Model

Weight
(Kg)

Full load
current
(A)

Weight
(Kg)

THGT/2-400-6/-1,1

1,1

4,1

2,3

Short
casing
37

THGT/2-560-6/-3

10,3

5,9

THGT/2-400-6/-1,5

1,5

5,5

3,1

44

50

THGT/2-560-6/-4

7,7

72

79

THGT/2-400-6/-2,2

2,2

8,0

4,6

46

52

THGT/2-560-6/-5,5

5,5

10,6

75

82

THGT/2-560-6/-7,5

7,5

14,1

89

96

THGT/2-560-6/-9,2

9,2

17,3

104

111

230 V

400 V

THGT/2-450-6/-2,2

2,2

THGT/2-450-6/-3

THGT/2-500-6/-2,2

2,2

THGT/2-500-6/-3

10,3

5,9

THGT/2-500-6/-4

7,7

THGT/2-500-6/-5,5

5,5

10,6

71

Long
casing
43

Motor
power
(kW)

230 V

400 V

Short
casing
59

Long
casing
66

8,0

4,6

48

54

10,3

5,9

52

58
THGT/2-630-6/-5,5

5,5

10,6

77

86

8,0

4,6

51

57

THGT/2-630-6/-7,5

7,5

14,1

91

100

55

61

THGT/2-630-6/-9,2

9,2

17,3

101

110

68

74

THGT/2-630-6/-11

11

20,4

135

152

77

THGT/2-630-6/-15

15

27,6

143

160

THGT/2-630-6/-18,5

18,5

33,7

155

172

We reserve right to supply different motors and hence data may change.

TECHNICAL CHARACTERISTICS - MOTORS F300 120 - 4 poles - 1450 rpm


Model

THGT/4-400-6/- 0,55

Motor
power
(kW)

0,55

Full load
current
(A)
230 V

400 V

2,2

1,3

Model

Weight
(Kg)
Short
casing
38

Long
casing
44

Motor
power
(kW)

Full load
current
(A)

Weight
(Kg)

THGT/4-800-3/-1,1

1,1

4,2

2,4

Short
casing
76

THGT/4-800-3/-1,5

1,5

5,7

3,3

77

98

THGT/4-800-3/-2,2

2,2

8,1

4,6

83

104

230 V

400 V

Long
casing
97

THGT/4-450-6/- 0,55

0,55

2,2

1,3

39

45

THGT/4-800-3/-3

10,7

6,2

86

107

THGT/4-500-6/-0,55

0,55

2,2

1,3

45

51

THGT/4-800-3/-4

8,1

99

120

THGT/4-500-6/-0,75

0,75

2,8

1,6

46

52

THGT/4-800-3/-5,5

5,5

10,5

112

133

THGT/4-500-6/-1,1

1,1

4,2

2,4

51

57
THGT/4-800-6/-1,5

1,5

5,7

3,3

81

101

THGT/4-560-6/-0,55

0,55

2,2

1,3

54

71

THGT/4-800-6/-2,2

2,2

8,1

4,6

87

107

THGT/4-560-6/-0,75

0,75

2,8

1,6

55

72

THGT/4-800-6/-3

10,7

6,2

90

11

THGT/4-560-6/-1,1

1,1

4,2

2,4

60

77

THGT/4-800-6/-4

8,1

103

123

THGT/4-560-6/-1,5

1,5

5,7

3,3

61

78

THGT/4-800-6/-5,5

5,5

10,5

116

136

THGT/4-560-6/-2,2

2,2

8,1

4,6

67

84

THGT/4-800-6/-7,5

7,5

14,1

130

150

THGT/4-630-6/-0,75

0,75

2,8

1,6

59

74

THGT/4-800-9/-2,2

2,2

8,1

4,6

90

111

THGT/4-630-6/-1,1

1,1

4,2

2,4

64

79

THGT/4-800-9/-3

10,7

6,2

93

114

THGT/4-630-6/-1,5

1,5

5,7

3,3

65

80

THGT/4-800-9/-4

8,1

106

127

THGT/4-630-6/-2,2

2,2

8,1

4,6

71

86

THGT/4-800-9/-5,5

5,5

10,5

119

140

THGT/4-630-6/-3

10,7

6,2

74

89

THGT/4-800-9/-7,5

7,5

14,1

133

154

THGT/4-710-3/-0,75

0,75

2,8

1,6

49

72

THGT/4-900-3/-2,2

2,2

8,1

4,6

96

119

THGT/4-710-3/-1,1

1,1

4,2

2,4

59

82

THGT/4-900-3/-3

10,7

6,2

99

122

THGT/4-710-3/-1,5

1,5

5,7

3,3

62

85

THGT/4-900-3/-4

8,1

112

135

THGT/4-710-3/-2,2

2,2

8,1

4,6

67

90

THGT/4-900-3/-5,5

5,5

10,5

125

148

THGT/4-710-3/-3

10,7

6,2

70

93

THGT/4-900-3/-7,5

7,5

14,1

139

162

THGT/4-710-6/-1,1

1,1

4,2

2,4

59

82

THGT/4-710-6/-1,5

1,5

5,7

3,3

62

85

THGT/4-710-6/-2,2

2,2

8,1

4,6

68

91

THGT/4-710-6/-3

10,7

6,2

71

94

THGT/4-710-6/-4

8,1

74

97

We reserve right to supply different motors and hence data may change.

www.solerpalau.com

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
TECHNICAL CHARACTERISTICS - MOTORS F300 120 - 4 poles - 1450 rpm (continuation)
Model

Motor
power
(kW)

Full load
current
(A)

Weight
(Kg)

Motor
power
(kW)

Full load
current
(A)

Weight
(Kg)

THGT/4-900-6/-3

10,7

6,2

Short
casing
104

THGT/4-1250-3/-7,5

7,5

14,1

Short
casing
183

THGT/4-900-6/-4

8,1

117

140

THGT/4-1250-3/-11

11

21,2

210

252

THGT/4-900-6/-5,5

5,5

10,5

130

153

THGT/4-1250-3/-15

15

28,7

238

280

THGT/4-900-6/-7,5

7,5

14,1

144

167

THGT/4-1250-3/-18,5

18,5

35,1

286

328

THGT/4-900-6/-11

11

21,2

171

194

THGT/4-1250-3/-22

22

40,5

287

329

THGT/4-1250-3/-30

30

56,2

347

389

230 V

400 V

Long
casing
127

Model

230 V

400 V

Long
casing
225

THGT/4-900-9/-5,5

5,5

10,5

135

157

THGT/4-900-9/-7,5

7,5

14,1

149

171

THGT/4-1250-6/-15

15

28,7

244

286

THGT/4-900-9/-11

11

21,2

176

198

THGT/4-1250-6/-18,5

18,5

35,1

292

334

THGT/4-900-9/-15

15

28,7

204

226

THGT/4-1250-6/-22

22

40,5

293

335

THGT/4-1250-6/-30

30

56,2

353

395

THGT/4-1000-3/-3

10,7

6,2

111

132

THGT/4-1250-6/-37

37

66,6

454

496

THGT/4-1000-3/-4

8,1

124

145

THGT/4-1250-6/-45

45

80,7

499

541

THGT/4-1000-3/-5,5

5,5

10,5

137

158

THGT/4-1000-3/-7,5

7,5

14,1

151

172

THGT/4-1250-9/-15

15

28,7

250

292

THGT/4-1000-3/-11

11

21,2

178

199

THGT/4-1250-9/-18,5

18,5

35,1

298

340

THGT/4-1250-9/-22

22

40,5

299

341

THGT/4-1000-6/-4

8,1

129

150

THGT/4-1250-9/-30

30

56,2

359

401

THGT/4-1000-6/-5,5

5,5

10,5

142

163

THGT/4-1250-9/-37

37

66,6

460

502

THGT/4-1000-6/-7,5

7,5

14,1

156

177

THGT/4-1250-9/-45

45

80,7

505

547

THGT/4-1000-6/-11

11

21,2

183

204

THGT/4-1000-6/-15

15

28,7

211

232

THGT/4-1000-6/-18,5

18,5

35,1

259

280

THGT/4-1000-9/-5,5

5,5

10,5

147

168

THGT/4-1000-9/-7,5

7,5

14,1

161

182

THGT/4-1000-9/-11

11

21,2

188

209

THGT/4-1000-9/-15

15

28,7

216

237

THGT/4-1000-9/-18,5

18,5

35,1

264

285

THGT/4-1000-9/-22

22

40,5

265

286

We reserve right to supply different motors and hence data may change.

Cylindrical cased axial ow fans THGT

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
TECHNICAL CHARACTERISTICS - MOTORS F300 120 - 6 poles - 950 rpm
Model

THGT/6-560-6/- 0,55

Motor
power
(kW)

0,55

Full load
current
(A)
230 V

400 V

2,6

1,5

Model

Weight
(Kg)
Short
casing
54

Long
casing
71

Motor
power
(kW)

Full load
current
(A)
230 V

400 V
3,7

THGT/6-1000-3/- 1,5

1,5

6,5

THGT/6-1000-3/- 2,2

2,2

9,2

Weight
(Kg)
Short
casing
106

Long
casing
127

5,3

115

136

THGT/6-630-6/- 0,55

0,55

2,6

1,5

57

72

THGT/6-1000-3/- 3

12,7

7,3

139

160

THGT/6-630-6/- 0,75

0,75

3,4

2,0

62

77

THGT/6-1000-3/- 4

9,5

145

166

THGT/6-630-6/- 1,1

1,1

4,8

2,8

66

81
THGT/6-1000-6/-1,5

1,5

6,5

3,7

113

134

THGT/6-710-3/- 0,55

0,55

2,6

1,5

57

80

THGT/6-1000-6/-2,2

2,2

9,2

5,3

123

144

THGT/6-710-3/- 0,75

0,75

3,4

2,0

59

82

THGT/6-1000-6/-3

12,7

7,3

147

168

THGT/6-1000-6/-4

9,5

153

174

THGT/6-1000-6/-5,5

5,5

12,8

157

178

THGT/6-710-6/- 0,55

0,55

2,6

1,5

60

83

THGT/6-710-6/- 0,75

0,75

3,4

2,0

62

85

THGT/6-710-6/- 1,1

1,1

4,8

2,8

65

88

THGT/6-1000-9/- 2,2

2,2

9,2

5,3

126

147

THGT/6-1000-9/- 3

12,7

7,3

150

171

THGT/6-1000-9/- 4

9,5

156

177

THGT/6-1000-9/- 5,5

5,5

12,8

160

181

THGT/6-1000-9/- 7,5

7,5

15,0

204

225

THGT/6-1250-3/-2,2

2,2

9,2

5,3

151

193

THGT/6-1250-3/-3

12,7

7,3

175

217

THGT/6-1250-3/-4

9,5

181

223

THGT/6-1250-3/-5,5

5,5

12,8

185

227

THGT/6-1250-3/-7,5

7,5

15,0

229

271

THGT/6-1250-3/-11

11

22,0

249

291

THGT/6-1250-6/- 4

9,5

190

232

THGT/6-1250-6/- 5,5

5,5

12,8

194

236

THGT/6-1250-6/- 7,5

7,5

15,0

238

280

THGT/6-800-3/- 0,55

0,55

2,6

1,5

67

88

THGT/6-800-3/- 0,75

0,75

3,4

2,0

69

90

THGT/6-800-3/- 1,1

1,1

4,8

2,8

72

93

THGT/6-800-3/- 1,5

1,5

6,5

3,7

79

100

THGT/6-800-6/- 0,55

0,55

2,6

1,5

71

91

THGT/6-800-6/- 0,75

0,75

3,4

2,0

73

93

THGT/6-800-6/- 1,1

1,1

4,8

2,8

76

96

THGT/6-800-6/- 1,5

1,5

6,5

3,7

83

103

THGT/6-800-6/- 2,2

2,2

9,2

5,3

97

107

THGT/6-800-9/- 0,75

0,75

3,4

2,0

79

100

THGT/6-800-9/- 1,1

1,1

4,8

2,8

83

104

THGT/6-800-9/- 1,5

1,5

6,5

3,7

89

110

THGT/6-800-9/- 2,2

2,2

9,2

5,3

98

119

THGT/6-800-9/- 3

12,7

7,3

122

143

THGT/6-900-3/- 1,5

1,5

6,4

3,7

95

118

THGT/6-900-3/- 2,2

2,2

9,2

5,3

104

127

THGT/6-900-6/- 1,5

1,5

6,5

3,7

99

122

THGT/6-1250-9/-11

THGT/6-900-6/- 2,2

2,2

9,2

5,3

108

131

THGT/6-900-6/- 3

THGT/6-900-6/- 4

THGT/6-900-9/- 1,5
THGT/6-900-9/- 2,2

12,7

7,3

132

THGT/6-1250-6/- 11

11

22,0

258

300

THGT/6-1250-6/- 15

15

27,9

296

338

THGT/6-1250-9/-5,5

5,5

12,8

200

242

THGT/6-1250-9/-7,5

7,5

15,0

244

286

11

22,0

264

306

THGT/6-1250-9/-15

15

27,9

302

344

155

THGT/6-1250-9/-18,5

18,5

35,7

342

384

THGT/6-1250-9/-22

22

42,3

360

402

9,5

138

161

1,5

6,5

3,7

103

125

2,2

9,2

5,3

113

135

THGT/6-900-9/- 3

12,7

7,3

137

159

THGT/6-900-9/- 4

9,5

143

165

THGT/6-900-9/- 5,5

5,5

12,8

147

169

We reserve right to supply different motors and hence data may change.

www.solerpalau.com

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
TECHNICAL CHARACTERISTICS - MOTORS F300-120
Before installation check that the product electrical characteristics listed on the data plate label (voltage, power, frequency, etc.) match those of the intended
electrical supply.

THGT 2 SPEED MODELS


TECHNICAL CHARACTERISTICS - MOTORS F300 120 - 2/4 poles - 2950/1450 rpm
Model

Motor
power
(kW)

Full load
current motor
(A)

Model

Weight
(Kg)

Full load
current motor
(A)

Weight
(Kg)

THGT/2/4-400-6/-1,1/0,25

1,1

0,25

2,5

0,7

Short
casing
37

THGT/2/4-560-6/-3,1/0,8

3,1

0,8

6,2

THGT/2/4-400-6/-1,5/0,35

1,5

0,35

3,8

0,9

44

50

THGT/2/4-560-6/-4,4/1,1

4,4

1,1

8,6

2,8

72

79

THGT/2/4-400-6/-2,2/0,6

2,2

0,6

4,8

1,5

46

52

THGT/2/4-560-6/-6/1,5

1,5

11,4

3,7

75

82

THGT/2/4-560-6/-8/2

15,3

4,8

89

96

THGT/2/4-450-6/-2,2/0,6

2,2

0,6

4,8

1,5

48

54

THGT/2/4-450-6/-3,1/0,8

3,1

0,8

6,2

2,0

52

58

THGT/2/4-630-6/-6/1,5

1,5

11,4

3,7

77

86

THGT/2/4-630-6/-8/2

15,3

4,8

91

100

V1

V2

V1

V2

Long
casing
43

Motor
power
(kW)
V1

V2

V1

V2
2,0

Short
casing
59

Long
casing
66

THGT/2/4-500-6/-2,2/0,6

2,2

0,6

4,8

1,5

51

57

THGT/2/4-630-6/-12/3

12

23,1

7,3

135

152

THGT/2/4-500-6/-3,1/0,8

3,1

0,8

6,2

2,0

55

61

THGT/2/4-630-6/-16/4

16

30,5

9,6

143

160

THGT/2/4-500-6/-4,4/1,1

4,4

1,1

8,6

2,8

68

74

THGT/2/4-500-6/-6/1,5

1,5

11,4

3,7

71

77

We reserve right to supply different motors and hence data may change.

TECHNICAL CHARACTERISTICS - MOTORS F300 120 - 4/8 poles - 1450-730 rpm


Model

Motor
power
(kW)

THGT/4/8-400-6/- 0,55/0,09

Full load
current motor
(A)

V1

V2

V1

V2

0,55

0,09

1,7

0,8

Model

Weight
(Kg)
Short
casing
33

Long
casing
39

Motor
power
(kW)

Full load
current motor
(A)

Weight
(Kg)

V1

V2

V1

V2

THGT/4/8-800-3/-1,1/0,18

1,1

0,18

2,7

1,2

Short
casing
76

Long
casing
97

THGT/4/8-800-3/-1,5/025

1,5

0,25

3,7

1,6

77

98

THGT/4/8-800-3/-2,2/0,37

2,2

0,37

4,7

1,7

83

104

THGT/4/8-800-3/-3/0,55

0,55

6,3

2,4

86

107

THGT/4/8-800-3/-4/0,75

0,75

8,4

2,3

99

120

THGT/4/8-800-3/-5,5/1,1

5,5

1,1

11,7

3,7

112

133

THGT/4/8-450-6/-0,55/0,09

0,55

0,09

1,7

0,8

38

44

THGT/4/8-500-6/-0,55/0,09

0,55

0,09

1,7

0,8

41

47

THGT/4/8-500-6/-0,75/0,12

0,75

0,12

2,3

0,9

42

48

THGT/4/8-500-6/-1,1/0,18

1,1

0,18

2,7

1,2

49

55

THGT/4/8-560-6/-0,55/0,09

0,55

0,09

1,7

0,8

45

52

THGT/4/8-800-6/-1,5/025

1,5

0,25

3,7

1,6

81

101

THGT/4/8-560-6/-0,75/0,12

0,75

0,12

2,3

0,9

46

53

THGT/4/8-800-6/-2,2/0,37

2,2

0,37

4,7

1,7

87

107

60

THGT/4/8-800-6/-3/0,55

0,55

6,3

2,4

90

11

0,75

8,4

2,3

103

123

THGT/4/8-560-6/-1,1/0,18

1,1

0,18

2,7

1,2

53

THGT/4/8-560-6/-1,5/025

1,5

0,25

3,7

1,6

56

63

THGT/4/8-800-6/-4/0,75

THGT/4/8-560-6/-2,2/0,37

2,2

0,37

4,7

1,7

58

65

THGT/4/8-800-6/-5,5/1,1

5,5

1,1

11,7

3,7

116

136

THGT/4/8-800-6/-7,5/1,5

7,5

1,5

15,9

4,7

130

150

THGT/4/8-630-6/-0,75/0,12

0,75

0,12

2,3

0,9

45

63

THGT/4/8-630-6/-1,1/0,18

1,1

0,18

2,7

1,2

55

64

THGT/4/8-800-9/-2,2/0,37

2,2

0,37

4,7

1,7

90

111

THGT/4/8-630-6/-1,5/025

1,5

0,25

3,7

1,6

58

67

THGT/4/8-800-9/-3/0,55

0,55

6,3

2,4

93

114

THGT/4/8-630-6/-2,2/0,37

2,2

0,37

4,7

1,7

60

69

THGT/4/8-800-9/-4/0,75

0,75

8,4

2,3

106

127

THGT/4/8-630-6/-3/0,55

0,55

6,3

2,4

64

73

THGT/4/8-800-9/-5,5/1,1

5,5

1,1

11,7

3,7

119

140

THGT/4/8-800-9/-7,5/1,5

7,5

1,5

15,9

4,7

133

154

THGT/4/8-710-3/-0,75/0,12

0,75

0,12

2,3

0,9

49

72

THGT/4/8-710-3/-1,1/0,18

1,1

0,18

2,7

1,2

59

82

THGT/4/8-900-3/-2,2/0,37

2,2

0,37

4,7

1,7

96

119

THGT/4/8-710-3/-1,5/025

1,5

0,25

3,7

1,6

62

85

THGT/4/8-900-3/-3/0,55

0,55

6,3

2,4

99

122

THGT/4/8-710-3/-2,2/0,37

2,2

0,37

4,7

1,7

67

90

THGT/4/8-900-3/-4/0,75

0,75

8,4

2,3

112

135

THGT/4/8-710-3/-3/0,55

0,55

6,3

2,4

70

93

THGT/4/8-900-3/-5,5/1,1

5,5

1,1

11,7

3,7

125

148

THGT/4/8-900-3/-7,5/1,5

7,5

1,5

15,9

4,7

139

162

THGT/4/8-710-6/-1,1/0,18

1,1

0,18

2,7

1,2

59

82

THGT/4/8-710-6/-1,5/025

1,5

0,25

3,7

1,6

62

85

THGT/4/8-710-6/-2,2/0,37

2,2

0,37

4,7

1,7

68

91

THGT/4/8-710-6/-3/0,55

0,55

6,3

2,4

71

94

THGT/4/8-710-6/-4/0,75

0,75

8,4

2,3

74

97

We reserve right to supply different motors and hence data may change.

Cylindrical cased axial ow fans THGT

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
TECHNICAL CHARACTERISTICS - MOTORS F300 120 - 4/8 poles - 1450-730 rpm (continuation)
Model

Motor
power
(kW)

Full load
current motor
(A)

Weight
(Kg)

Model

Motor
power
(kW)

Full load
current motor
(A)

2,3

Short
casing
104

Long
casing
127

1,5

15,9

3,7

117

140

THGT/4/8-1250-3/-11/3

11

21,0

15,9

4,7

130

153

THGT/4/8-1250-3/-17/4,3

17

4,3

21,0

7,0

144

167

THGT/4/8-1250-3/-20/5

20

4,3

33,4

12,7

171

194

THGT/4/8-1250-3/-28/6,5
THGT/4/8-1250-3/-35/8

V1

V2

V1

V2

THGT/4/8-900-6/-4/0,75

THGT/4/8-900-6/-5,5/1,1

5,5

0,75

8,4

1,1

11,7

THGT/4/8-900-6/-7,5/1,5

7,5

1,5

THGT/4/8-900-6/-11/3

11

THGT/4/8-900-6/-17/4,3

17

4,7

Short
casing
183

Long
casing
225

7,0

210

252

33,4

12,7

238

280

38,6

14,1

286

328

28

6,5

52,0

18,0

287

329

35

67,3

21,8

347

389

V1
THGT/4/8-1250-3/-7,5/1,5

Weight
(Kg)

7,5

V2

V1

V2

THGT/4/8-900-9/-5,5/1,1

5,5

1,1

11,7

3,7

135

157

THGT/4/8-900-9/-7,5/1,5

7,5

1,5

15,9

4,7

149

171

THGT/4/8-1250-6/-17/4,3

17

4,3

33,4

12,7

244

286

THGT/4/8-900-9/-11/3

11

21,0

7,0

176

198

THGT/4/8-1250-6/-20/5

20

38,6

14,1

292

334

THGT/4/8-900-9/-17/4,3

17

4,3

33,4

12,7

204

226

THGT/4/8-1250-6/-28/6,5

28

6,5

52,0

18,0

293

335

THGT/4/8-1250-6/-35/8

35

67,3

21,8

353

395

THGT/4/8-1250-6/-37/9,2

37

9,2

74,2

25,4

454

496

THGT/4/8-1250-6/-44/11

44

80,2

27,2

499

541

THGT/4/8-1000-3/-3/0,55

0,55

6,3

2,4

111

132

THGT/4/8-1000-3/-4/0,75

0,75

8,4

2,3

124

145

THGT/4/8-1000-3/-5,5/1,1

5,5

1,1

11,7

3,7

137

158

THGT/4/8-1000-3/-7,5/1,5

7,5

1,5

15,9

4,7

151

172

THGT/4/8-1000-3/-11/3

11

21,0

7,0

178

199

THGT/4/8-1000-6/-4/0,75

0,75

8,4

2,3

129

THGT/4/8-1000-6/-5,5/1,1

5,5

1,1

11,7

3,7

THGT/4/8-1000-6/-7,5/1,5

7,5

1,5

15,9

4,7

11

THGT/4/8-1250-9/-17/4,3

17

4,3

33,4

12,7

250

292

THGT/4/8-1250-9/-20/5

20

38,6

14,1

298

340

150

THGT/4/8-1250-9/-28/6,5

28

6,5

52,0

18,0

299

341

142

163

THGT/4/8-1250-9/-35/8

35

67,3

21,8

359

401

156

177

THGT/4/8-1250-9/-37/9,2

37

9,2

74,2

25,4

460

502

THGT/4/8-1250-9/-44/11

44

80,2

27,2

505

547

THGT/4/8-1000-6/-11/3

11

21,0

7,0

183

204

THGT/4/8-1000-6/-17/4,3

17

4,3

33,4

12,7

211

232

THGT/4/8-1000-6/-20/5

20

38,6

14,1

259

280

THGT/4/8-1000-9/-5,5/1,1

5,5

1,1

11,7

3,7

147

168

THGT/4/8-1000-9/-7,5/1,5

7,5

1,5

15,9

4,7

161

182

THGT/4/8-1000-9/-11/3

11

21,0

7,0

188

209

THGT/4/8-1000-9/-17/4,3

17

4,3

33,4

12,7

216

237

THGT/4/8-1000-9/-20/5

20

38,6

14,1

264

285

11

We reserve right to supply different motors and hence data may change.

www.solerpalau.com

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
TECHNICAL CHARACTERISTICS - MOTORS F300 120 - 6/12 poles - 950-475 rpm
Model

Motor
power
(kW)

THGT/6/12-560-6/- 0,55/0,09

Full load
current motor
(A)

V1

V2

V1

V2

0,55

0,09

2,1

0,9

Model

Weight
(Kg)
Short
casing
54

Long
casing
71

Motor
power
(kW)

Full load
current motor
(A)

Weight
(Kg)

1,7

Short
casing
106

Long
casing
127

V1

V2

V1

V2

THGT/6/12-1000-3/- 1,5/0,25

1,5

0,25

4,2

THGT/6/12-1000-3/- 2,2/0,37

2,2

0,37

5,7

2,2

115

136

THGT/6/12-630-6/- 0,55/0,09

0,55

0,09

2,1

0,9

57

72

THGT/6/12-1000-3/- 3/0,55

0,55

8,9

3,8

139

160

THGT/6/12-630-6/- 0,75/0,12

0,75

0,12

2,3

1,0

62

77

THGT/6/12-1000-3/- 4/0,65

0,65

9,3

2,9

145

166

THGT/6/12-630-6/- 1,1/0,18

1,1

0,18

4,5

1,7

66

81
THGT/6/12-1000-6/-1,5/0,25

1,5

0,25

4,2

1,7

113

134

THGT/6/12-710-3/- 0,55/0,09

0,55

0,09

2,1

0,9

57

80

THGT/6/12-1000-6/-2,2/0,37

2,2

0,37

5,7

2,2

123

144

THGT/6/12-710-3/- 0,75/0,12

0,75

0,12

2,3

1,0

59

82

THGT/6/12-1000-6/-3/0,55

0,55

8,9

3,8

147

168

THGT/6/12-1000-6/-4/0,65

0,65

9,3

2,9

153

174

THGT/6/12-1000-6/-6/1,2

1,2

13,4

5,6

157

178

THGT/6/12-1000-9/- 2,2/0,37

2,2

0,37

5,7

2,2

126

147

THGT/6/12-1000-9/- 3/0,55

0,55

8,9

3,8

150

171

THGT/6/12-1000-9/- 4/0,65

0,65

9,3

2,9

156

177

THGT/6/12-1000-9/- 6/1,2

1,2

13,4

5,6

160

181

THGT/6/12-1000-9/- 7,5/1,5

7,5

1,5

16,4

6,5

204

225

THGT/6/12-1250-3/-2,2/0,37

2,2

0,37

5,7

2,2

151

193

THGT/6/12-1250-3/-3/0,55

0,55

8,9

3,8

175

217

THGT/6/12-1250-3/-4/0,65

0,65

9,3

2,9

181

223

THGT/6/12-1250-3/-6/1,2

1,2

13,4

5,6

185

227

THGT/6/12-1250-3/-7,5/1,5

7,5

1,5

16,4

6,5

229

271

23,4

8,1

249

291

THGT/6/12-710-6/- 0,55/0,09

0,55

0,09

2,1

0,9

60

83

THGT/6/12-710-6/- 0,75/0,12

0,75

0,12

2,3

1,0

62

85

THGT/6/12-710-6/- 1,1/0,18

1,1

0,18

4,5

1,7

65

88

THGT/6/12-800-3/- 0,55/0,09

0,55

0,09

2,1

0,9

67

88

THGT/6/12-800-3/- 0,75/0,12

0,75

0,12

2,3

1,0

69

90

THGT/6/12-800-3/- 1,1/0,18

1,1

0,18

4,5

1,7

72

93

THGT/6/12-800-3/- 1,5/0,25

1,5

0,25

4,2

1,7

79

100

THGT/6/12-800-6/- 0,55/0,09

0,55

0,09

2,1

0,9

71

91

THGT/6/12-800-6/- 0,75/0,12

0,75

0,12

2,3

1,0

73

93

THGT/6/12-800-6/- 1,1/0,18

1,1

0,18

4,5

1,7

76

96

THGT/6/12-800-6/- 1,5/0,25

1,5

0,25

4,2

1,7

83

103

THGT/6/12-800-6/- 2,2/0,37

2,2

0,37

5,7

2,2

97

107

THGT/6/12-800-9/- 0,75/0,12

0,75

0,12

2,3

1,0

79

100

THGT/6/12-800-9/- 1,1/0,18

1,1

0,18

4,5

1,7

83

104

THGT/6/12-800-9/- 1,5/0,25

1,5

0,25

4,2

1,7

89

110

THGT/6/12-800-9/- 2,2/0,37

2,2

0,37

5,7

2,2

98

119

THGT/6/12-800-9/- 3/0,55

0,55

8,9

3,8

122

143

THGT/6/12-900-3/- 1,5/0,25

1,5

0,25

4,2

1,7

95

118

THGT/6/12-900-3/- 2,2/0,37

2,2

0,37

5,7

2,2

104

127

THGT/6/12-900-6/- 1,5/0,25

1,5

0,25

4,2

1,7

99

122

THGT/6/12-1250-9/-12/2,4

THGT/6/12-900-6/- 2,2/0,37

2,2

0,37

5,7

2,2

108

131

THGT/6/12-900-6/- 3/0,55

0,55

8,9

3,8

132

THGT/6/12-1250-3/-12/2,4

12

2,4

THGT/6/12-1250-6/- 4/0,65

0,65

9,3

2,9

190

232

THGT/6/12-1250-6/- 6/1,2

1,2

13,4

5,6

194

236

THGT/6/12-1250-6/- 7,5/1,5

7,5

1,5

16,4

6,5

238

280

THGT/6/12-1250-6/- 12/2,4

12

2,4

23,4

8,1

258

300

THGT/6/12-1250-6/- 17/4,3

17

4,3

31,0

10,2

296

338

THGT/6/12-1250-9/-6/1,2

1,2

13,4

5,6

200

242

THGT/6/12-1250-9/-7,5/1,5

7,5

1,5

16,4

6,5

244

286

12

2,4

23,4

8,1

264

306

THGT/6/12-1250-9/-17/4,3

17

4,3

31,0

10,2

302

344

155

THGT/6/12-1250-9/-20/5

20

39,0

14,3

342

384

THGT/6/12-1250-9/-28/6,5

28

6,5

52,6

17,9

360

402

THGT/6/12-900-6/- 4/0,65

0,65

9,3

2,9

138

161

THGT/6/12-900-9/- 1,5/0,25

1,5

0,25

4,2

1,7

103

125

THGT/6/12-900-9/- 2,2/0,37

2,2

0,37

5,7

2,2

113

135

THGT/6/12-900-9/- 3/0,55

0,55

8,9

3,8

137

159

THGT/6/12-900-9/- 4/0,65

0,65

9,3

2,9

143

165

THGT/6/12-900-9/- 6/1,2

1,2

13,4

5,6

147

169

We reserve right to supply different motors and hence data may change.

Cylindrical cased axial ow fans THGT

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
TECHNICAL CHARACTERISTICS - MOTORS F200-120
Before installation check that the product electrical characteristics listed on the data plate label (voltage, power, frequency, etc.) match those of the intended
electrical supply.

THGT 1 SPEED MODELS


TECHNICAL CHARACTERISTICS - MOTORS F200 120 - 2 poles - 2950 rpm
Model

Motor
power
(kW)

Full load
current
(A)

Model

Weight
(Kg)

Full load
current
(A)

Weight
(Kg)

THGT/2-400-6/-1,1

1,1

3,9

2,3

Short
casing
37

THGT/2-560-6/-3

10,3

5,9

THGT/2-400-6/-1,5

1,5

5,2

3,0

44

50

THGT/2-560-6/-4

7,1

72

79

THGT/2-400-6/-2,2

2,2

7,7

4,4

46

52

THGT/2-560-6/-5,5

5,5

10,3

75

82

THGT/2-560-6/-7,5

7,5

13,3

89

96

THGT/2-560-6/-9,2

11

19,2

104

111

230 V

400 V

THGT/2-450-6/-2,2

2,2

THGT/2-450-6/-3

THGT/2-500-6/-2,2

2,2

THGT/2-500-6/-3

10,3

5,9

THGT/2-500-6/-4

7,1

THGT/2-500-6/-5,5

5,5

10,3

71

Long
casing
43

Motor
power
(kW)

230 V

400 V

Short
casing
59

Long
casing
66

7,7

4,4

48

54

10,3

5,9

52

58
THGT/2-630-6/-5,5

5,5

10,3

77

86

7,7

4,4

51

57

THGT/2-630-6/-7,5

7,5

13,3

91

100

55

61

THGT/2-630-6/-11

11

19,2

135

152

68

74

THGT/2-630-6/-15

15

26,0

143

160

77

THGT/2-630-6/-18,5

18,5

32,5

155

172

We reserve right to supply different motors and hence data may change.

TECHNICAL CHARACTERISTICS - MOTORS F200 120 - 4 poles - 1450 rpm


Model

THGT/4-400-6/- 0,55

Motor
power
(kW)

0,55

Full load
current
(A)
230 V

400 V

2,4

1,4

Model

Weight
(Kg)
Short
casing
38

Long
casing
44

Motor
power
(kW)

Full load
current
(A)

Weight
(Kg)

THGT/4-800-3/-1,1

1,1

4,2

2,4

Short
casing
76

THGT/4-800-3/-1,5

1,5

5,6

3,2

77

98

THGT/4-800-3/-2,2

2,2

8,3

4,8

83

104

THGT/4-800-3/-3

11,3

6,5

86

107

THGT/4-800-3/-4

8,6

99

120

THGT/4-800-3/-5,5

5,5

10,6

112

133

230 V

400 V

Long
casing
97

THGT/4-450-6/- 0,55

0,55

2,4

1,4

39

45

THGT/4-500-6/-0,55

0,55

2,4

1,4

45

51

THGT/4-500-6/-0,75

0,75

3,3

1,9

46

52

THGT/4-500-6/-1,1

1,1

4,2

2,4

51

57

THGT/4-560-6/-0,55

0,55

2,4

1,4

54

71

THGT/4-800-6/-1,5

1,5

5,6

3,2

81

101

THGT/4-560-6/-0,75

0,75

3,3

1,9

55

72

THGT/4-800-6/-2,2

2,2

8,3

4,8

87

107

THGT/4-560-6/-1,1

1,1

4,2

2,4

60

77

THGT/4-800-6/-3

11,3

6,5

90

11

THGT/4-560-6/-1,5

1,5

5,6

3,2

61

78

THGT/4-800-6/-4

8,6

103

123

THGT/4-560-6/-2,2

2,2

8,3

4,8

67

84

THGT/4-800-6/-5,5

5,5

10,6

116

136

THGT/4-800-6/-7,5

7,5

14,0

130

150

THGT/4-630-6/-0,75

0,75

3,3

1,9

59

74

THGT/4-630-6/-1,1

1,1

4,2

2,4

64

79

THGT/4-800-9/-2,2

2,2

8,3

4,8

90

111

THGT/4-630-6/-1,5

1,5

5,6

3,2

65

80

THGT/4-800-9/-3

11,3

6,5

93

114

THGT/4-630-6/-2,2

2,2

8,3

4,8

71

86

THGT/4-800-9/-4

8,6

106

127

THGT/4-630-6/-3

11,3

6,5

74

89

THGT/4-800-9/-5,5

5,5

10,6

119

140

THGT/4-800-9/-7,5

7,5

14,0

133

154

TGT/4-710-3/-0,75

0,75

3,3

1,9

49

72

TGT/4-710-3/-1,1

1,1

4,2

2,4

59

82

THGT/4-900-3/-2,2

2,2

8,3

4,8

96

119

TGT/4-710-3/-1,5

1,5

5,6

3,2

62

85

THGT/4-900-3/-3

11,3

6,5

99

122

TGT/4-710-3/-2,2

2,2

8,3

4,8

67

90

THGT/4-900-3/-4

8,6

112

135

TGT/4-710-3/-3

11,3

6,5

70

93

THGT/4-900-3/-5,5

5,5

10,6

125

148

THGT/4-900-3/-7,5

7,5

14,0

139

162

TGT/4-710-6/-1,1

1,1

4,2

2,4

59

82

TGT/4-710-6/-1,5

1,5

5,6

3,2

62

85

TGT/4-710-6/-2,2

2,2

8,3

4,8

68

91

TGT/4-710-6/-3

11,3

6,5

71

94

TGT/4-710-6/-4

8,6

74

97

We reserve right to supply different motors and hence data may change.

www.solerpalau.com

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
TECHNICAL CHARACTERISTICS - MOTORS F200 120 - 4 poles - 1450 rpm (continuation)
Model

Motor
power
(kW)

Full load
current
(A)

Model

Weight
(Kg)

Full load
current
(A)

Weight
(Kg)

THGT/4-900-6/-3

11,3

6,5

Short
casing
104

THGT/4-1250-3/-7,5

7,5

14,0

Short
casing
183

THGT/4-900-6/-4

8,6

117

140

THGT/4-1250-3/-11

11

21,0

210

252

THGT/4-900-6/-5,5

5,5

10,6

130

153

THGT/4-1250-3/-15

15

28,5

238

280

THGT/4-900-6/-7,5

7,5

14,0

144

167

THGT/4-1250-3/-18,5

18,5

34,0

286

328

THGT/4-900-6/-11

11

21,0

171

194

THGT/4-1250-3/-22

22

41,0

287

329

THGT/4-1250-3/-30

30

55,0

347

389

230 V

400 V

Long
casing
127

Motor
power
(kW)

230 V

400 V

Long
casing
225

THGT/4-900-9/-5,5

5,5

10,6

135

157

THGT/4-900-9/-7,5

7,5

14,0

149

171

THGT/4-1250-6/-15

15

28,5

244

286

THGT/4-900-9/-11

11

21,0

176

198

THGT/4-1250-6/-18,5

18,5

34,0

292

334

THGT/4-900-9/-15

15

28,5

204

226

THGT/4-1250-6/-22

22

41,0

293

335

THGT/4-1250-6/-30

30

55,0

353

395

THGT/4-1000-3/-3

11,3

6,5

111

132

THGT/4-1250-6/-37

37

68,0

454

496

THGT/4-1000-3/-4

8,6

124

145

THGT/4-1250-6/-45

45

80,0

499

541

THGT/4-1000-3/-5,5

5,5

10,6

137

158

THGT/4-1000-3/-7,5

7,5

14,0

151

172

THGT/4-1250-9/-15

15

28,5

250

292

THGT/4-1000-3/-11

11

21,0

178

199

THGT/4-1250-9/-18,5

18,5

34,0

298

340

THGT/4-1250-9/-22

22

41,0

299

341

THGT/4-1000-6/-4

8,6

129

150

THGT/4-1250-9/-30

30

55,0

359

401

THGT/4-1000-6/-5,5

5,5

10,6

142

163

THGT/4-1250-9/-37

37

68,0

460

502

THGT/4-1000-6/-7,5

7,5

14,0

156

177

THGT/4-1250-9/-45

45

80,0

505

547

THGT/4-1000-6/-11

11

21,0

183

204

THGT/4-1000-6/-15

15

28,5

211

232

THGT/4-1000-6/-18,5

18,5

34,0

259

280

THGT/4-1000-9/-5,5

5,5

10,6

147

168

THGT/4-1000-9/-7,5

7,5

14,0

161

182

THGT/4-1000-9/-11

11

21,0

188

209

THGT/4-1000-9/-15

15

28,5

216

237

THGT/4-1000-9/-18,5

18,5

34,0

264

285

THGT/4-1000-9/-22

22

41,0

265

286

We reserve right to supply different motors and hence data may change.

Cylindrical cased axial ow fans THGT

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
TECHNICAL CHARACTERISTICS - MOTORS F200 120 - 6 poles - 950 rpm
Model

THGT/6-560-6/- 0,55

Motor
power
(kW)

0,55

Full load
current
(A)
230 V

400 V

2,7

1,6

Model

Weight
(Kg)
Short
casing
54

Long
casing
71

Motor
power
(kW)

Full load
current
(A)

Weight
(Kg)

THGT/6-1000-3/- 1,5

1,5

6,8

3,9

Short
casing
106

THGT/6-1000-3/- 2,2

2,2

8,9

230 V

400 V

Long
casing
127

5,1

115

136

THGT/6-630-6/- 0,55

0,55

2,7

1,6

57

72

THGT/6-1000-3/- 3

11,1

6,4

139

160

THGT/6-630-6/- 0,75

0,75

4,1

2,4

62

77

THGT/6-1000-3/- 4

8,3

145

166

THGT/6-630-6/- 1,1

1,1

5,7

3,3

66

81
THGT/6-1000-6/-1,5

1,5

6,8

3,9

113

134

TGT/6-710-3/- 0,55

0,55

2,7

1,6

57

80

THGT/6-1000-6/-2,2

2,2

8,9

5,1

123

144

TGT/6-710-3/- 0,75

0,75

4,1

2,4

59

82

THGT/6-1000-6/-3

11,1

6,4

147

168

THGT/6-1000-6/-4

8,3

153

174

THGT/6-1000-6/-5,5

5,5

12,0

157

178

TGT/6-710-6/- 0,55

0,55

2,7

1,6

60

83

TGT/6-710-6/- 0,75

0,75

4,1

2,4

62

85

TGT/6-710-6/- 1,1

1,1

5,7

3,3

65

88

THGT/6-1000-9/- 2,2

2,2

8,9

5,1

126

147

THGT/6-1000-9/- 3

11,1

6,4

150

171

TGT/6-800-3/- 0,55

0,55

2,7

1,6

67

88

THGT/6-1000-9/- 4

8,3

156

177

TGT/6-800-3/- 0,75

0,75

4,1

2,4

69

90

THGT/6-1000-9/- 5,5

5,5

12,0

160

181

TGT/6-800-3/- 1,1

1,1

5,7

3,3

72

93

THGT/6-1000-9/- 7,5

7,5

15,6

204

225

TGT/6-800-3/- 1,5

1,5

6,8

3,9

79

100
THGT/6-1250-3/-2,2

2,2

8,9

5,1

151

193

TGT/6-800-6/- 0,55

0,55

2,7

1,6

71

91

THGT/6-1250-3/-3

11,1

6,4

175

217

TGT/6-800-6/- 0,75

0,75

4,1

2,4

73

93

THGT/6-1250-3/-4

8,3

181

223

TGT/6-800-6/- 1,1

1,1

5,7

3,3

76

96

THGT/6-1250-3/-5,5

5,5

12,0

185

227

TGT/6-800-6/- 1,5

1,5

6,8

3,9

83

103

THGT/6-1250-3/-7,5

7,5

15,6

229

271

TGT/6-800-6/- 2,2

2,2

8,9

5,1

97

107

THGT/6-1250-3/-11

11

23,0

249

291

THGT/6-800-9/- 0,75

0,75

4,1

2,4

79

100

THGT/6-1250-6/- 4

8,3

190

232

THGT/6-800-9/- 1,1

1,1

5,7

3,3

83

104

THGT/6-1250-6/- 5,5

5,5

12,0

194

236

THGT/6-800-9/- 1,5

1,5

6,8

3,9

89

110

THGT/6-1250-6/- 7,5

7,5

15,6

238

280

THGT/6-800-9/- 2,2

2,2

8,9

5,1

98

119

THGT/6-1250-6/- 11

11

23,0

258

300

THGT/6-800-9/- 3

11,1

6,4

122

143

THGT/6-1250-6/- 15

15

31,0

296

338

THGT/6-900-3/- 1,5

1,5

6,8

3,9

95

118

THGT/6-1250-9/-5,5

5,5

12,0

200

242

THGT/6-900-3/- 2,2

2,2

8,9

5,1

104

127

THGT/6-1250-9/-7,5

7,5

15,6

244

286

THGT/6-1250-9/-11

11

23,0

264

306

THGT/6-900-6/- 1,5

1,5

6,8

3,9

99

122

THGT/6-1250-9/-15

15

31,0

302

344

THGT/6-900-6/- 2,2

2,2

8,9

5,1

108

131

THGT/6-1250-9/-18,5

18,5

36,0

342

384

THGT/6-900-6/- 3

11,1

6,4

132

155

THGT/6-1250-9/-22

22

42,0

360

402

THGT/6-900-6/- 4

8,3

138

161

THGT/6-900-9/- 1,5

1,5

6,8

3,9

103

125

THGT/6-900-9/- 2,2

2,2

8,9

5,1

113

135

THGT/6-900-9/- 3

11,1

6,4

137

159

THGT/6-900-9/- 4

8,3

143

165

THGT/6-900-9/- 5,5

5,5

12,0

147

169

We reserve right to supply different motors and hence data may change.

www.solerpalau.com

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
TECHNICAL CHARACTERISTICS - MOTORS F200-120
Before installation check that the product electrical characteristics listed on the data plate label (voltage, power, frequency, etc.) match those of the intended
electrical supply.

THGT 2 SPEED MODELS


TECHNICAL CHARACTERISTICS - MOTORS F200 120 - 2/4 poles - 2950/1450 rpm
Model

Motor
power
(kW)

Full load
current motor
(A)

Model

Weight
(Kg)

Full load
current motor
(A)

Weight
(Kg)

THGT/2/4-400-6/-1,1/0,25

1,1

0,25

2,4

0,9

Short
casing
37

THGT/2/4-560-6/-3/0,6

0,6

6,2

1,9

Short
casing
59

THGT/2/4-400-6/-1,5/0,33

1,5

0,33

3,3

1,1

44

50

THGT/2/4-560-6/-4,5/1

4,5

8,4

2,4

72

79

THGT/2/4-400-6/-2,2/0,45

2,2

0,45

4,6

1,4

46

52

THGT/2/4-560-6/-6,2/1,3

6,2

1,3

11,8

3,5

75

82

THGT/2/4-560-6/-8,3/1,7

8,3

1,7

15,4

4,2

89

96

THGT/2/4-630-6/-6,2/1,3

1,5

11,4

3,7

77

86

THGT/2/4-630-6/-8,3/1,7

8,3

1,7

15,4

4,2

91

100

V1

V2

V1

V2

Long
casing
43

Motor
power
(kW)

THGT/2/4-450-6/-2,2/0,45

2,2

0,45

4,6

1,4

48

54

THGT/2/4-450-6/-3/0,6

0,6

6,2

1,9

52

58

V1

V2

V1

V2

Long
casing
66

THGT/2/4-500-6/-2,2/0,45

2,2

0,45

4,6

1,4

51

57

THGT/2/4-630-6/-12/3

12

23,1

7,3

135

152

THGT/2/4-500-6/-3/0,6

0,6

6,2

1,9

55

61

THGT/2/4-630-6/-16/3,2

16

3,2

28,5

7,0

143

160

THGT/2/4-500-6/-4,5/1

4,5

8,4

2,4

68

74

THGT/2/4-500-6/-6,2/1,3

6,2

1,3

11,8

3,5

71

77

We reserve right to supply different motors and hence data may change.

TECHNICAL CHARACTERISTICS - MOTORS F200 120 - 4/8 poles - 1450-730 rpm


Model

Motor
power
(kW)

THGT/4/8-400-6/- 0,55/0,13

Full load
current motor
(A)

V1

V2

V1

V2

0,55

0,13

1,8

0,7

Model

Weight
(Kg)
Short
casing
33

Long
casing
39

Motor
power
(kW)

Full load
current motor
(A)

Weight
(Kg)

V1

V2

V1

V2

THGT/4/8-800-3/-1,1/0,26

1,1

0,26

2,8

1,2

Short
casing
76

Long
casing
97

THGT/4/8-800-3/-1,7/0,35

1,7

0,35

4,0

1,6

77

98

THGT/4/8-800-3/-2,3/0,5

2,3

0,5

5,2

1,9

83

104

THGT/4/8-800-3/-3/0,65

0,65

6,8

2,5

86

107

THGT/4/8-800-3/-4/0,75

0,75

8,7

3,5

99

120

THGT/4/8-800-3/-6,8/1,4

6,8

1,4

13,7

5,1

112

133

THGT/4/8-450-6/-0,55/0,13

0,55

0,13

1,8

0,7

38

44

THGT/4/8-500-6/-0,55/0,13

0,55

0,13

1,8

0,7

41

47

THGT/4/8-500-6/-0,75/0,12

0,75

0,12

2,3

0,9

42

48

THGT/4/8-500-6/-1,1/0,26

1,1

0,26

2,8

1,2

49

55

THGT/4/8-560-6/-0,55/0,13

0,55

0,13

1,8

0,7

45

52

THGT/4/8-800-6/-1,7/0,35

1,7

0,35

4,0

1,6

81

101

53

THGT/4/8-800-6/-2,3/0,5

2,3

0,5

5,2

1,9

87

107

60

THGT/4/8-800-6/-3/0,65

0,65

6,8

2,5

90

11

0,75

8,7

3,5

103

123

THGT/4/8-560-6/-0,75/0,12
THGT/4/8-560-6/-1,1/0,26

0,75
1,1

0,12
0,26

2,3
2,8

0,9
1,2

46
53

THGT/4/8-560-6/-1,7/0,35

1,7

0,35

4,0

1,6

56

63

THGT/4/8-800-6/-4/0,75

THGT/4/8-560-6/-2,3/0,5

2,3

0,5

5,2

1,9

58

65

THGT/4/8-800-6/-6,8/1,4

6,8

1,4

13,7

5,1

116

136

THGT/4/8-800-6/-8,4/2,05

8,4

2,05

16,6

6,2

130

150

THGT/4/8-630-6/-0,75/0,12

0,75

0,12

2,3

0,9

45

63

THGT/4/8-630-6/-1,1/0,26

1,1

0,26

2,8

1,2

55

64

THGT/4/8-800-9/-2,3/0,5

2,3

0,5

5,2

1,9

90

111

THGT/4/8-630-6/-1,7/0,35

1,7

0,35

4,0

1,6

58

67

THGT/4/8-800-9/-3/0,65

0,65

6,8

2,5

93

114

THGT/4/8-630-6/-2,3/0,5

2,3

0,5

5,2

1,9

60

69

THGT/4/8-800-9/-4/0,75

0,75

8,7

3,5

106

127

THGT/4/8-630-6/-3/0,55

0,65

6,8

2,5

64

73

THGT/4/8-800-9/-6,8/1,4

6,8

1,4

13,7

5,1

119

140

THGT/4/8-800-9/-8,4/2,05

8,4

2,05

16,6

6,2

133

154

THGT/4/8-710-3/-0,75/0,12

0,75

0,12

2,3

0,9

49

72

THGT/4/8-710-3/-1,1/0,26

1,1

0,26

2,8

1,2

59

82

THGT/4/8-710-3/-1,7/0,35

1,7

0,35

4,0

1,6

62

85

THGT/4/8-710-3/-2,3/0,5

2,3

0,5

5,2

1,9

67

90

THGT/4/8-710-3/-3/0,65

0,65

6,8

2,5

70

93

THGT/4/8-710-6/-1,1/0,26

1,1

0,26

2,8

1,2

59

82

THGT/4/8-710-6/-1,7/0,35

1,7

0,35

4,0

1,6

62

85

THGT/4/8-710-6/-2,3/0,5

2,3

0,5

5,2

1,9

68

91

THGT/4/8-710-6/-3/0,65

0,65

6,8

2,5

71

94

THGT/4/8-710-6/-4/0,75

0,75

8,7

3,5

74

97

We reserve right to supply different motors and hence data may change.

Cylindrical cased axial ow fans THGT

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
TECHNICAL CHARACTERISTICS - MOTORS F200 120 - 4/8 poles - 1450-730 rpm (continuation)
Model

Motor
power
(kW)

Full load
current motor
(A)

Weight
(Kg)

Motor
power
(kW)

Full load
current motor
(A)

Weight
(Kg)

THGT/4/8-900-3/-2,3/0,5

2,3

0,5

5,2

1,9

Short
casing
96

THGT/4/8-1000-9/-6,8/1,4

6,8

1,4

13,7

5,1

THGT/4/8-900-3/-3/0,65

0,65

6,8

2,5

99

122

THGT/4/8-1000-9/-8,4/2,05

8,4

2,05

16,6

6,2

161

182

THGT/4/8-900-3/-4/0,75

0,75

8,7

3,5

112

135

THGT/4/8-1000-9/-10,5/2,2

10,5

2,2

21,0

7,4

188

209

V1

V2

V1

V2

Long
casing
119

Model

V1

V2

V1

V2

Short
casing
147

Long
casing
168

THGT/4/8-900-3/-6,8/1,4

6,8

1,4

13,7

5,1

125

148

THGT/4/8-1000-9/-15,5/2,7

15,5

2,7

30,0

9,5

216

237

THGT/4/8-900-3/-8,4/2,05

8,4

2,05

16,6

6,2

139

162

THGT/4/8-1000-9/-22/4,4

22

4,4

43,0

15,0

265

286

THGT/4/8-900-6/-4/0,75

0,75

8,7

3,5

104

127

THGT/4/8-1250-3/-8,4/2,05

8,4

THGT/4/8-900-6/-6,8/1,4

6,8

1,4

13,7

5,1

117

140

THGT/4/8-1250-3/-10,5/2,2

10,5

2,05

16,6

6,2

183

225

2,2

21,0

7,4

210

252

THGT/4/8-900-6/-8,4/2,05

8,4

130

153

THGT/4/8-1250-3/-15,5/2,7

15,5

2,7

30,0

9,5

238

280

THGT/4/8-900-6/-10,5/2,2

10,5

2,2

21,0

7,4

144

167

THGT/4/8-1250-3/-22/4,4

22

4,4

43,0

15,0

287

329

THGT/4/8-900-6/-17/4,3

15,5

2,7

30,0

9,5

171

194

THGT/4/8-1250-3/-33/8

33

61,0

21,0

347

389

THGT/4/8-900-9/-6,8/1,4

6,8

1,4

13,7

5,1

135

157

THGT/4/8-1250-6/-15,5/2,7

15,5

2,7

30,0

9,5

244

286

THGT/4/8-900-9/-8,4/2,05

8,4

2,05

16,6

6,2

149

171

THGT/4/8-1250-6/-22/4,4

22

4,4

43,0

15,0

293

335

THGT/4/8-900-9/-10,5/2,2

10,5

2,2

21,0

7,4

176

198

THGT/4/8-1250-6/-33/8

33

61,0

21,0

353

395

THGT/4/8-900-9/-17/4,3

15,5

2,7

30,0

9,5

204

226

THGT/4/8-1250-6/-42/10

42

10

85,0

27,0

454

496

THGT/4/8-1000-3/-3/0,65

0,65

6,8

2,5

111

132

THGT/4/8-1000-3/-4/0,75

0,75

8,7

3,5

124

145

THGT/4/8-1000-3/-6,8/1,4

6,8

1,4

13,7

5,1

137

158

THGT/4/8-1000-3/-8,4/2,05

8,4

2,05

16,6

6,2

151

172

THGT/4/8-1000-3/-10,5/2,2

10,5

2,2

21,0

7,4

178

199

THGT/4/8-1000-6/-4/0,75

0,75

8,7

3,5

129

150

THGT/4/8-1000-6/-6,8/1,4

6,8

1,4

13,7

5,1

142

163

THGT/4/8-1000-6/-8,4/2,05

8,4

THGT/4/8-1000-6/-10,5/2,2

10,5

2,05

16,6

6,2

156

177

2,2

21,0

7,4

183

204

THGT/4/8-1000-6/-15,5/2,7

15,5

2,7

30,0

9,5

211

232

THGT/4/8-1000-6/-22/4,4

22

4,4

43,0

15,0

259

280

THGT/4/8-1250-9/-15,5/2,7

15,5

2,7

30,0

9,5

250

292

THGT/4/8-1250-9/-22/4,4

22

4,4

43,0

15,0

299

341

THGT/4/8-1250-9/-33/8

33

61,0

21,0

359

401

THGT/4/8-1250-9/-42/10

42

10

85,0

27,0

460

502

We reserve right to supply different motors and hence data may change.

www.solerpalau.com

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
TECHNICAL CHARACTERISTICS - MOTORS F200 120 - 6/12 poles - 950-475 rpm
Model

Motor
power
(kW)

THGT/6/12-560-6/- 0,75/0,15

Full load
current motor
(A)

V1

V2

V1

V2

0,75

0,15

2,1

0,8

Model

Weight
(Kg)
Short
casing
54

Long
casing
71

Motor
power
(kW)

Full load
current motor
(A)

Weight
(Kg)

1,5

Short
casing
106

Long
casing
127

V1

V2

V1

V2

THGT/6/12-1000-3/- 1,5/0,25

1,5

0,25

4,0

THGT/6/12-1000-3/- 2,2/0,37

2,2

0,37

5,6

2,1

115

136

THGT/6/12-630-6/- 0,75/0,15

0,75

0,15

2,1

0,8

62

77

THGT/6/12-1000-3/- 3/0,55

0,55

8,0

3,8

139

160

THGT/6/12-630-6/- 1,3/0,2

1,3

0,2

3,5

1,2

66

81

THGT/6/12-1000-3/- 4/0,65

0,65

10,4

3,1

145

166

THGT/6/12-710-3/- 0,75/0,15

0,75

0,15

2,1

0,8

59

82

THGT/6/12-1000-6/-1,5/0,25

1,5

0,25

4,0

1,5

113

134

THGT/6/12-1000-6/-2,2/0,37

2,2

0,37

5,6

2,1

123

144

THGT/6/12-710-6/- 0,75/0,15

0,75

0,15

2,1

0,8

62

85

THGT/6/12-1000-6/-3/0,55

0,55

8,0

3,8

147

168

THGT/6/12-710-6/- 1,3/0,2

1,3

0,2

3,5

1,2

65

88

THGT/6/12-1000-6/-4/0,65

0,65

10,4

3,1

153

174

THGT/6/12-1000-6/-5,5/1

5,5

14,1

5,4

157

178

THGT/6/12-1000-9/- 2,2/0,37

2,2

0,37

5,6

2,1

126

147

THGT/6/12-1000-9/- 3/0,55

0,55

8,0

3,8

150

171

THGT/6/12-1000-9/- 4/0,65

0,65

10,4

3,1

156

177

THGT/6/12-800-3/- 0,75/0,15

0,75

0,15

2,1

0,8

69

90

THGT/6/12-800-3/- 1,3/0,2

1,3

0,2

3,5

1,2

72

93

THGT/6/12-800-3/- 1,5

1,5

0,25

4,0

1,5

79

100

THGT/6/12-800-6/- 0,75/0,15

0,75

0,15

2,1

0,8

73

93

THGT/6/12-1000-9/- 5,5/1

5,5

14,1

5,4

160

181

THGT/6/12-800-6/- 1,3/0,2

1,3

0,2

3,5

1,2

76

96

THGT/6/12-1000-9/- 7,5/1,3

7,5

1,3

17,5

5,5

204

225

THGT/6/12-800-6/- 1,5/0,25

1,5

0,25

4,0

1,5

83

103

THGT/6/12-800-6/- 2,2/0,37

2,2

0,37

5,6

2,1

97

107

THGT/6/12-1250-3/-2,2/0,37

2,2

0,37

5,6

2,1

151

193

THGT/6/12-1250-3/-3/0,55

0,55

8,0

3,8

175

217

THGT/6/12-800-9/- 0,75/0,15

0,75

0,15

2,1

0,8

79

100

THGT/6/12-1250-3/-4/0,65

0,65

10,4

3,1

181

223

THGT/6/12-800-9/- 1,3/0,2

1,3

0,2

3,5

1,2

83

104

THGT/6/12-1250-3/-5,5/1

5,5

14,1

5,4

185

227

THGT/6/12-800-9/- 1,5/0,25

1,5

0,25

4,0

1,5

89

110

THGT/6/12-1250-3/-7,5/1,3

7,5

1,3

17,5

5,5

229

271

THGT/6/12-800-9/- 2,2/0,37

2,2

0,37

5,6

2,1

98

119

THGT/6/12-1250-3/-11/1,8

11

1,8

26,2

8,0

249

291

THGT/6/12-800-9/- 3/0,55

0,55

8,0

3,8

122

143
THGT/6/12-1250-6/- 4/0,65

0,65

10,4

3,1

190

232

THGT/6/12-900-3/- 1,5/0,25

1,5

0,25

4,0

1,5

95

118

THGT/6/12-1250-6/- 5,5/1

5,5

14,1

5,4

194

236

THGT/6/12-900-3/- 2,2/0,37

2,2

0,37

5,7

2,2

104

127

THGT/6/12-1250-6/- 7,5/1,3

7,5

1,3

17,5

5,5

238

280

THGT/6/12-1250-6/- 11/1,8

11

1,8

26,2

8,0

258

300

THGT/6/12-1250-6/- 15/2,5

15

2,5

33,4

10,4

296

338

THGT/6/12-900-6/- 1,5/0,25

1,5

0,25

4,0

1,5

99

122

THGT/6/12-900-6/- 2,2/0,37

2,2

0,37

5,6

2,1

108

131

THGT/6/12-900-6/- 3/0,55

0,55

8,0

3,8

132

155

THGT/6/12-1250-9/-5,5/1

5,5

14,1

5,4

200

242

THGT/6/12-900-6/- 4/0,65

0,65

10,4

3,1

138

161

THGT/6/12-1250-9/-7,5/1,3

7,5

1,3

17,5

5,5

244

286

THGT/6/12-1250-9/-11/1,8

11

1,8

26,2

8,0

264

306

THGT/6/12-900-9/- 1,5/0,25

1,5

0,25

4,0

1,5

103

125

THGT/6/12-1250-9/-15/2,5

15

2,5

33,4

10,4

302

344

THGT/6/12-900-9/- 2,2/0,37

2,2

0,37

5,6

2,1

113

135

THGT/6/12-1250-9/-18,5/3

18,5

38,2

11,5

342

384

THGT/6/12-900-9/- 3/0,55

0,55

8,0

3,8

137

159

THGT/6/12-1250-9/-25/4,5

25

4,5

52,2

16,6

360

402

THGT/6/12-900-9/- 4/0,65

0,65

10,4

3,1

143

165

THGT/6/12-900-9/- 5,5/1

5,5

14,1

5,4

147

169

We reserve right to supply different motors and hence data may change.

Cylindrical cased axial ow fans THGT

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
DIMENSIONS (mm)

AL

AC

N x F

C max

THGT short casing

THGT long casing

Model

AC

AL

400

250

380

400

402

450

487

12

450

250

480

450

457

500

537

12

500

250

480

500

467

560

595

12

12

560

280

600

560

564

620

655

12

12

630

280

600 (700*)

630

564

690

725

12

12

710

380

600

710

564

770

806

12

16

800

380

600

800

564

860

896

12

16

900

450

750

900

737

970

1005

15

16

1000

450

780

1000

767

1070

1105

15

16

1250

500

1150

1250

895

1320

1355

15

20

* F200-120 2 pole motors 11kW AL=700

www.solerpalau.com

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
MOUNTING ACCESSORIES
Model

Circular duct
matching flange

Bellmouth
protection guard

Circular flexible
connector

Inlet grille guard

Outlet grille guard

400

ARO BRIDA THGT-400 N

EMB- 400T

ACOPEL F400-400/160 N

DEF.ASP.TGT/THGT-400 (impeller side)

DEF. DES. TGT/ THGT-400 (motor side)

450

ARO BRIDA THGT-450 N

EMB- 450T

ACOPEL F400-450/160 N

DEF.ASP.TGT/THGT-450 (impeller side)

DEF. DES. TGT/ THGT-450 (motor side)

500

ARO BRIDA THGT-500 N

EMB- 500T

ACOPEL F400-500/160 N

DEF.ASP.TGT/THGT-500 (impeller side)

DEF. DES. TGT/ THGT-500 (motor side)

560

ARO BRIDA THGT-560 N

EMB- 560T

ACOPEL F400-560/160 N

DEF.ASP.TGT/THGT-560 (impeller side)

DEF. DES. TGT/ THGT-560 (motor side)

630

ARO BRIDA THGT-630 N

EMB- 630T

ACOPEL F400-630/160 N

DEF.ASP.TGT/THGT-630 (impeller side)

DEF. DES. TGT/ THGT-630 (motor side)

710

ARO BRIDA THGT-710 N

EMB- 710T

ACOPEL F400-710/180 N

DEF.ASP.TGT/THGT-710 (impeller side)

DEF. DES. TGT/ THGT-710 (motor side)

800

ARO BRIDA THGT-800 N

EMB- 800T

ACOPEL F400-800/180 N

DEF.ASP.TGT/THGT-800 (impeller side)

DEF. DES. TGT/ THGT-800 (motor side)

900

ARO BRIDA THGT-900 N

EMB- 900T

ACOPEL F400-900/180 N

DEF.ASP.TGT/THGT-900 (impeller side)

DEF. DES. TGT/ THGT-900 (motor side)

1000

ARO BRIDA THGT-1000 N

EMB- 1000T

ACOPEL F400-1000/180 N DEF.ASP.TGT/THGT-1000 (impeller side) DEF. DES. TGT/ THGT-1000 (motor side)

1250

ARO BRIDA THGT-1250 N

EMB- 1250T

ACOPEL F400-1250/200 N DEF.ASP.TGT/THGT-1250 (impeller side) DEF. DES. TGT/ THGT-1250 (motor side)

Model

Support feet (horizontal)

Support feet (vertical)

Back draft
shutter

Circular sound
attenuator

Attenuator with
acoustic pod

400

PIE SOPORTE TGT/THGT-400

PIE SOPORTE TGT/THGT-400 V

CLAR-400

SIL CZ 400

SIL CZO 400

450

PIE SOPORTE TGT/THGT-450

PIE SOPORTE TGT/THGT-450 V

CLAR-450

SIL CZ 450

SIL CZO 450

500

PIE SOPORTE TGT/THGT-500

PIE SOPORTE TGT/THGT-500 V

CLAR-500

SIL CZ 500

SIL CZO 500

560

PIE SOPORTE TGT/THGT-560

PIE SOPORTE TGT/THGT-560 V

CLAR 560

SIL CZ 560

SIL CZO 560

630

PIE SOPORTE TGT/THGT-630

PIE SOPORTE TGT/THGT-630 V

CLAR 630

SIL CZ 630

SIL CZO 630

710

PIE SOPORTE TGT/THGT-710

PIE SOPORTE TGT/THGT-710 V

CLAR 710

SIL CZ 710

SIL CZO 710

800

PIE SOPORTE TGT/THGT-800

PIE SOPORTE TGT/THGT-800 V

CLAR 800

SIL CZ 800

SIL CZO 800

900

PIE SOPORTE TGT/THGT-900

PIE SOPORTE TGT/THGT-900 V

CLAR 900

SIL CZ 900

SIL CZO 900

1000

PIE SOPORTE TGT/THGT-1000

PIE SOPORTE TGT/THGT-1000 V

CLAR 1000

SIL CZ 1000

SIL CZO 1000

1250

PIE SOPORTE TGT/THGT-1250

PIE SOPORTE TGT/THGT-1250 V

CLAR 1250

SIL CZ 1250

SIL CZO 1250

Antivibration mount

Divide the total


weight of the fan by
4, as you need 4
antivibration mounts
per unit. (see the table
in the mounting
accesories).

For more information see Mounting accessories.

Cylindrical cased axial ow fans THGT

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
FITTING ANTI-VIBRATION MOUNTS IN THE SHORT CASING MODELS
OUTLET

INLET

Defensa descarga
Inlet grille

air-stream direction
Flexible flange connector

Matching flange

Ducting

Matching flange

Ducting

Support feet

Back draft
shutter

Inlet adapter
protection guard

For more information see Mounting accessories.

FITTING ANTI-VIBRATION MOUNTS IN THE SHORT CASING MODELS


When fitting anti-vibration mountings,
short casing models, it is recommended
they are fitted to a suitable support frame
(not supplied by S&P) following the
minimum distances as specified in the table.

L min.

www.solerpalau.com

THGT model

L min.

R min.

Total

400

370

60

430

450

430

70

500

500

440

70

510

560

550

80

630

630

550

80

630

710

550

80

630

800

550

90

640

900

750

100

850

1000

750

100

850

1250

900

100

1000

R
min.

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
EXAMPLE OF SELECTING THGT FANS
3

qv: Air volume in m /h and m /s.


psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

sf

psf

(Pa)
121416

32
600

30

28

10
8

THGT
Number of poles

500

Nominal diameter (mm)


Number of blades

1000
6

400

Working point of
maximum efficiency
(curve 16)

THGT/4-1000-6/_-_kW
Hz

102

105

26
20 22
24
18
102

102

104

300

105

103

100

101

104 dB(A) [LwA]

63

38

38

31

125

22

21

19

250

12

12

500

1000

2000

4000

13

14

11

8000

21

23

19

200

100

120

Table of correction factors for the calculation of the


sound power level spectrum.

0
10000

Pabs
(W)

THE SOUND LEVEL VALUES IN THE PERFORMANCE CURVES


CORRESPOND TO SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES LpA, SUBTRACT
REDUCTION DUE TO DISTANCE.

105

20000

102

30000

40000

11,1

101

100

50000
13

Required working point:


Airflow..................: 40,000 m3/hr = 11,1 m3/s
Pressure...: 23.4 mmWG

15

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

80000 qv [m3/h]

70000

17

19

qv [m3/s]

21

18000

32
30
28

14000

26
24
22
20

7200
6000

With the required volume and pressure calculated, trace along the vertical axis (against volume
value: 40,000 m3/h) and horizontal axis (against pressure value: 23.4 mmWG) to the point of
intersection as shown. This intersection point lies on the fan curve (green line) with 18 blade pitch
angle. From this point we can also approximate the sound power level as being 99 dB(A), as this
value lies between 100 dB(A) and 98 dB(A).
On the same graphic, the intersection point with the red line gives the dynamic pressure with 12.4 mmWG.
On the bottom part of the graphic, the intersection point with the fan curve (18) gives, on the left
scale, the absorbed power (4,768W) at the motor shaft. We recommend to apply a 10% security
margin on this value to select the motor power (horizontal red line directly above this value and
corresponding with the recommended power motor shown on the right scale 5,5kW).
Depending on the noise area (A, B, C), to obtain the sound power level spectrum, subtract the correction
factors corresponding on the area (in this case B) from the global value lain on the graph (99 dB(A)).

103

60000

10000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

18
8 10

2000
10000

20000

30000

12

40000

16

14

50000

VSD* SR* d[%]*

60000

80000 qv [m3/h]

70000

N*

[kW]

[m3/h]

[Pa] [RPM]

Total

No

53,5

55,9

4,208

22.032

367

1451

10

Total

No

56,4

58,5

4,684

24.054

395

1445

12

5,5

Total

No

57,7

59,3

5,699

28.352

418

1474

14

7,5

Total

No

62,5

63,8

6,360

33.975

421

1474

16

7,5

Total

No

64,5

65,3

7,412

37.265

461

1469

PM* MC*

EC*

18

11

Total

No

68,3

68,7

8,801

40.215

536

1478

20

11

Total

No

66,9

66,9

9,902

43.479

548

1476

22

11

Total

No

67,1

67,1

11,216 49.012

552

1470

24

11

Total

No

66,0

65,9

12,726 50.974

594

1466

26

15

Total

No

64,1

63,9

14,662 53.641

632

1473

28

18,5

Total

No

65,4

65,1

16,138 61.355

618

1488

30

18,5

Total

No

65,7

65,3

18,333 60.204

720

1486

32

18,5

Total

No

67,5

67,0

19,838 64.313

749

1481

Its total sound power level is 103 dB(A), (the sound level average value).
The sound spectrum can be calculated from the noise area (the three areas delimited by grey lines):
A, B, or C. In this case the working point is at the A area. To obtain the value of the spectrum for every
octave band. For every eighth, the coefficient should be subtracted from the total sound power level.
At 3 meters of distance, the sound pressure level is 65 dB(A).

Spectrum sound power level


Hz
63
125
250
500
1000
2000
4000
8000

dB(A)
103
103
103
103
103
103
103
103

A
38
22
12
5
4
7
13
21

Sound pressure spectrum


Lw dB(A)
65
81
91
98
99
96
90
82

Cylindrical cased axial ow fans THGT

The resulting model would be


THGT/4-1000/6-16-7,5 kW

Hz
63
125
250
500
1000
2000
4000
8000

dB(A)
65
81
91
98
99
96
90
82

Atten.
20
20
20
20
20
20
20
20

Lp dB(A)
45
61
71
78
79
76
70
62

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 2 POLE MOTORS - THGT F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf
[Pa]

450

32
400

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

27
93

350

91
300

250

90dB(A) [LwA]
THGT F400
Number of poles

200

Nominal diameter (mm)

91

400

Number of blades

150

THGT/2-400-6/_-_KW

100

Acoustic characteristics
Sound power spectrum: The sound levels shown in these tables are sound power levels
at the outlet and inlet, in dB(A) for frequency ranges at three points of the curve:
A- free outlet, B- medium pressure, C- maximum pressure.
THGT/2- 400-6/27

63

125

250

500

1.000

2.000

50

63

74

83

87

86

81

74

47

65

74

82

87

86

82

75

49

65

75

83

88

87

83

76

THGT/2- 400-6/32

63

125

250 500

1.000

2.000

56

69

88

86

86

0
2000

3000

4000

5000

6000

7000

8000 qv [m3/h]

4.000 8.000

80

90

92

50

4.000 8.000
83

0.6

0.8

1.2

1.4

1.6

1.8

2.2

qv [m3/s]

P [W ]
1800

76

49

66

76

82

86

85

81

74

49

66

76

83

86

85

82

74

1600

1400

32
1200

27

1000

800
2000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

www.solerpalau.com

3000

4000

5000

VSD* SR* d[%]*

6000

7000

8000 qv [m3/h]

N*

[kW]

[m3/h]

[Pa] [RPM]

27

1,1

Total

No

39,8

45,2

1,394

4.832

413

2888

32

1,5

Total

No

40,2

45,0

1,767

5.772

441

2915

PM* MC*

EC*

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 2 POLE MOTORS - THGT F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf
[Pa]

32
500

27

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

98
400

96
22
95

300

95dB(A) [LwA]

THGT F400
Number of poles

91

Nominal diameter (mm)

450

Number of blades

93

200

THGT/2-450-6/_-_KW

95

100

92
94
Acoustic characteristics
Sound power spectrum: The sound levels shown in these tables are sound power levels
at the outlet and inlet, in dB(A) for frequency ranges at three points of the curve:
A- free outlet, B- medium pressure, C- maximum pressure.
THGT/2- 450-6/22

63

125

250

500

1000

2000

4000

8000

51

64

76

89

91

89

85

77

48

62

77

85

88

88

82

71

49

63

78

86

90

89

84

73

THGT/2- 450-6/27

63

125

250

500

1000

2000

4000

8000

55

68

79

88

92

91

86

78

48

65

74

82

87

86

82

75

48

65

74

82

88

86

83

75

THGT/2- 450-6/32

63

125 250

500

1000

2000

4000

8000

61

74

85

92

94

92

88

81

53

70

80

87

90

89

86

78

53

70

80

87

90

89

86

78

0
4000

5000

1.2

1.4

6000
1.6

7000
1.8

8000

9000

2.2

2.4

2.6

10000
2.8

11000
3

12000 qv [m3/h]
3.2

qv [m3/s]

P [W ]

3000

32

2500

2000

27
1500

22
1000
4000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

Cylindrical cased axial ow fans THGT

5000

6000

7000

8000

VSD* SR* d[%]*

9000

10000

11000

12000 qv [m3/h]

PM* MC*

EC*

N*

[kW]

[m3/h]

[Pa] [RPM]

22

1,5

Total

No

40,4

45,3

1,699

6.290

391

2924

27

2,2

Total

No

44,6

48,4

2,474

7.536

527

2897

32

Total

No

43,3

46,4

3,199

9.049

549

2944

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 2 POLE MOTORS - THGT F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf
[Pa]

27
22
500

101

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

400

101

17
102

95dB(A) [LwA]

300
THGT F400

97

Number of poles

Nominal diameter (mm)

500

Number of blades

200

97

THGT/2-500-6/_-_KW

95

100

97
97
Acoustic characteristics
Sound power spectrum: The sound levels shown in these tables are sound power levels
at the outlet and inlet, in dB(A) for frequency ranges at three points of the curve:
A- free outlet, B- medium pressure, C- maximum pressure.
THGT/2- 500-6/17

63

125

250

500

1000

2000

4000

8000

57

70

84

95

99

96

90

81

53

67

83

90

93

92

87

80

53

66

82

90

93

91

87

79

THGT/2- 500-6/22

63

125

250

500

1000

2000

4000

8000

57

70

82

95

97

95

91

83

52

66

81

89

93

92

87

76

52

66

81

90

93

92

87

76

THGT/2- 500-6/27

63

125

250

500

1000

2000

4000

8000

60

74

84

93

97

96

91

84

52

69

78

86

91

90

86

79

52

69

78

86

91

90

86

79

0
5000
P [W ]
4500

1.4

6000
1.6

7000
1.8

8000
2.2

9000
2.4

10000

2.6

2.8

11000
3

12000

3.2

13000

3.4

3.6

14000
3.8

15000 qv [m3/h]

qv [m3/s]

4000

27

3500

3000

2500

22
2000

17
1500
5000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

www.solerpalau.com

6000

7000

8000

9000

10000

VSD* SR* d[%]*

11000

12000

13000

14000

N*

[kW]

[m3/h]

40,7

45,0

2,081

7.529

404

45,3

48,6

3,039

9.387

525

2945

44,2

46,5

4,353 11.660

590

2900

PM* MC*

EC*

17

1,5

Total

No

22

Total

No

27

Total

No

15000 qv [m3/h]

[Pa] [RPM]
2897

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 2 POLE MOTORS - THGT F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf
[Pa]

27
700

17

22
107

600

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

108
108
500

400

100dB(A) [LwA]
101

THGT F400
Number of poles

102

Nominal diameter (mm)

300

560

Number of blades

200
THGT/2-560-6/_-_KW

99
101
100

Acoustic characteristics
Sound power spectrum: The sound levels shown in these tables are sound power levels
at the outlet and inlet, in dB(A) for frequency ranges at three points of the curve:
A- free outlet, B- medium pressure, C- maximum pressure.
THGT/2- 560-6/17

63

125

250

500

1000

2000

4000

8000

63

76

90

101

105

102

96

87

58

71

87

95

98

96

92

84

57

70

86

94

97

95

91

84

THGT/2- 560-6/22

63

125

250

500

1000

2000

4000

8000

63

76

88

101

104

102

97

90

56

70

85

94

97

96

91

80

56

70

85

93

97

96

91

80

THGT/2- 560-6/27

63

125

250

500

1000

2000

4000

8000

66

79

90

99

103

102

97

90

56

73

83

91

96

95

91

83

56

72

82

90

95

94

90

83

101

0
6000

8000
2

10000
2.5

12000
3

3.5

14000

16000

4.5

Cylindrical cased axial ow fans THGT

22000 qv [m3/h]

5.5

qv [m3/s]

7000

6000

27
5000

22

4000

17

2000
6000

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

20000

P [W ]

3000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

18000

8000

10000

12000

14000

VSD* SR* d[%]*

PM* MC*

EC*

17

Total

No

22

5,5

Total

No

27

7,5

Total

No

16000

18000
[m3/h]

20000

N*

[kW]

44,4

47,2

3,649 10.641

549

2917

48,1

49,9

5,246 14.055

642

2948

51,8

52,6

7,543 16.577

847

2936

22000 qv [m3/h]

[Pa] [RPM]

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 2 POLE MOTORS - THGT F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf

17

[Pa]

22

900

27
800

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

32

113

113

700

114
114

600

500

107dB(A) [LwA]
104

THGT F400
Number of poles
Nominal diameter (mm)

106

400

107

630

Number of blades

300

THGT/2-630-6/_-_KW

200

105

100
Acoustic characteristics
Sound power spectrum: The sound levels shown in these tables are sound power levels
at the outlet and inlet, in dB(A) for frequency ranges at three points of the curve:
A- free outlet, B- medium pressure, C- maximum pressure.
THGT/2- 630-6/17

63

125

250

500

1000

2000

4000

8000

69

82

97

107

111

109

103

94

62

76

92

100

103

101

97

89

61

74

90

98

102

100

95

88

THGT/2- 630-6/22

63

125

250

500

1000

2000

4000

8000

70

83

95

108

110

108

104

97

61

74

90

98

102

101

96

85

60

74

89

98

101

100

95

84

THGT/2- 630-6/27

63

125

250

500

1000

2000

4000

8000

72

85

96

105

109

108

103

96

61

78

87

95

101

99

95

88

60

76

86

94

100

98

94

87

THGT/2- 630-6/32

63

125

250

500

1000

2000

4000

8000

76

89

100

106

108

106

103

96

66

83

92

99

102

102

98

91

65

82

92

99

102

101

98

90

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

www.solerpalau.com

0
8000

12000

16000

20000
5

24000
6

106

103

105

28000
7

32000

36000 qv [m3/h]

10

qv [m3/s]

P [W ]
16000
14000

32

12000
10000

27

8000

22
6000

17
4000
8000

12000

16000

PM* MC*
17
22

EC*

20000

24000

VSD* SR* d[%]*

28000

[m3/h]

32000

36000 qv [m3/h]

N*

[kW]

7,5

Total

No

50,4

51,7

6,267 15.928

[Pa] [RPM]
715

2951

7,5

Total

No

52,6

53,0

8,672 19.355

848

2929

27

11

Total

No

51,6

51,6 11,664 23.893

906

2936

32

15

Total

No

47,7

47,4 16,045 27.305 1009

2936

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 2 POLE MOTORS - THGT F200 - F300
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

psf
[Pa]

20
18

400

94

Nominal diameter (mm)


Number of blades

63

92

92

94

92

91

92dB(A) [LwA]

400

200

THGT/2-400-6/_-_ kW
Hz

94

300
THGT F200 - F300
Number of poles

26
24
22

16

500

30 32 34
28

42

43

36

125

29

30

23

250

17

17

14

500

1000

2000

4000

10

8000

17

19

14

Table of correction factors for the calculation of the


sound power level spectrum.

100

0
2000

94

3000

0.6

0.8

4000
1

1.2

92

5000

91

6000

1.4

1.6

91

7000
1.8

8000

2.2

9000
2.4

10000 qv [m3/h]

2.6

qv [m3/s]

P [W ]

2200

34
1800

32
30
1400

28
26
24

1000

22
16

600
2000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

Cylindrical cased axial ow fans THGT

3000

4000

PM* MC*

EC*

18 20

5000

6000

VSD* SR* d[%]*

7000

8000

N*

[kW]

[m3/h]

9000

10000 qv [m3/h]

[Pa] [RPM]

16

1,1

Total

No

38,8

45,2

0,984

3653

376

2932

18

1,1

Total

No

41,2

47,3

1,099

4080

398

2924

20

1,5

Total

No

46,5

52,3

1,202

4428

454

2953

22

1,5

Total

No

48,8

54,3

1,364

5033

473

2942

24

1,5

Total

No

48,8

54,0

1,503

5283

497

2932

26

1,5

Total

No

48,4

53,4

1,616

5735

487

2931

28

2,2

Total

No

48,5

53,2

1,816

6295

500

2933

30

2,2

Total

No

47,6

52,0

2,034

6676

520

2922

32

2,2

Total

No

46,5

50,7

2,190

7059

516

2919

34

2,2

Total

No

45,2

49,1

2,421

7207

544

2909

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 2 POLE MOTORS - THGT F200 - F300
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf
[Pa]

26

600

24

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

400

Number of blades

97

450

100

96

95dB(A) [LwA]

200
THGT/4-450-6/_-_ kW
Hz

98

300

Nominal diameter (mm)

22
20

18

102

THGT F200 - F300


Number of poles

16

500

63

42

43

36

125

29

30

23

250

17

17

14

500

1000

2000

4000

10

8000

17

19

14

Table of correction factors for the calculation of the


sound power level spectrum.

100

99

0
4000

5000

1.2

6000

95

7000

1.6

8000

9000
2.4

95

10000

11000

2.8

12000 qv [m3/h]
3.2

qv [m3/s]

P [W ]

2600

2200

26
22

1800

24

20
1400

16

1000
4000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

www.solerpalau.com

5000

6000

PM* MC*

EC*

7000

18

8000

VSD* SR* d[%]*

9000

10000

N*

[kW]

[m3/h]

11000

12000 qv [m3/h]

[Pa] [RPM]

16

1,5

Total

No

41,3

46,1

1,754

5726

454

2918

18

1,5

Total

No

43,5

48,0

1,955

6115

500

2909

20

2,2

Total

No

47,2

51,3

2,235

7012

541

2913

22

2,2

Total

No

49,1

53,0

2,465

7602

572

2906

24

2,2

Total

No

49,1

52,7

2,717

7936

605

2890

26

Total

No

59,2

62,7

2,858

9425

642

2940

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 2 POLE MOTORS - THGT F200 - F300
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf
[Pa]

8 101214

900

800

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

700

98

500
THGT F200 - F300
Number of poles

Nominal diameter (mm)


Number of blades

B
100

103

98

97dB(A) [LwA]

300

200
63

98

400

500

THGT/2-500-6/_-_ kW
Hz

26
24
20 22
16 18
100

105

600

42

43

36

125

29

30

23

250

17

17

14

500

1000

2000

4000

10

8000

17

19

14

Table of correction factors for the calculation of the


sound power level spectrum.

100

100
0
2000

4000

0.5

102

6000

1.5

8000
2

98

10000

2.5

12000
3.5

97

14000

16000 qv [m3/h]

4.5

qv [m3/s]

P [W ]
4500
4000

26
24

3500

22

3000

20
2500

16

2000

12
1500

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

Cylindrical cased axial ow fans THGT

14

10

1000
2000

18

4000

6000

8000

PM* MC*

EC*

2,2

Total

No

10

2,2

Total

No

12

2,2

Total

No

14

2,2

Total

16

18

20

22

10000

VSD* SR* d[%]*

12000

14000

16000 qv [m3/h]

N*

[kW]

[m3/h]

40,5

45,3

1,739

4009

630

2935

41,8

46,2

2,048

4805

643

2924

45,1

49,2

2,239

5694

639

2909

No

46,7

50,6

2,456

7433

556

2896

Total

No

47,0

50,5

2,795

8525

555

2953

Total

No

49,5

52,7

3,126

9419

591

2945

Total

No

50,2

53,1

3,506

10220

619

2923

Total

No

49,3

51,8

4,018

11085

642

2917

24

Total

No

50,1

52,4

4,344

11665

670

2897

26

Total

No

49,8

51,8

4,790

12561

681

2884

[Pa] [RPM]

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 2 POLE MOTORS - THGT F200 - F300
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf
[Pa]

1000

8101214

900

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

101

18

Number of blades

101

22
20 103

16

Nominal diameter (mm)

104

106

101

100dB(A) [LwA]

400

560
6

300
THGT/2-560-6/_-_ kW
Hz

108

700

500

Number of poles

28

24

800

600

THGT F200 - F300

26

63

42

43

36

125

29

30

23

250

17

17

14

500

1000

2000

4000

10

8000

17

19

14

Table of correction factors for the calculation of the


sound power level spectrum.

200

100

0
4000

104

8000

105

12000

101

16000
4

100

20000

24000

28000 qv [m3/h]
7

qv [m3/s]
3

P [W ]
10000
9000

28
8000

26
7000

24

6000

22
5000

20

4000

16

3000

8 10

2000
4000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

www.solerpalau.com

18

7000

10000

12

13000

14

16000

VSD* SR* d[%]*

19000

22000

25000

N*

[kW]

[m3/h]

44,8

48,1

3,030

6466

755

2948

45,9

48,9

3,343

7272

760

2942

47,7

50,5

3,582

9803

627

2922

No

50,6

53,1

4,086

11113

669

2911

Total

No

52,8

54,7

5,001

12938

734

2948

Total

No

54,0

55,5

5,734

14390

771

2940

Total

No

55,1

56,3

6,411

15509

819

2950

7,5

Total

No

55,9

56,8

7,223

16381

886

2941

24

7,5

Total

No

55,8

56,4

8,027

17570

917

2933

26

9,2

Total

No

56,1

56,5

8,803

19003

935

2948

28

9,2

Total

No

53,7

53,8

9,626

19776

942

2943

PM* MC*

EC*

Total

No

10

Total

No

12

Total

No

14

5,5

Total

16

5,5

18

7,5

20

7,5

22

28000 qv [m3/h]

[Pa] [RPM]

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 2 POLE MOTORS - THGT F200 - F300
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf
[Pa]

1400

101214

1300

8
1200

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

1100

Nominal diameter (mm)


Number of blades

111

105

900

700

Number of poles

18 20
22

1000

800
THGT

16
24 26

107

28 30
32
107

107

600

630

108

109

107

107

104dB(A) [LwA]

500

400
THGT/2-630-6/_-_ kW

300
Hz

63

42

43

36

125

29

30

23

250

17

17

14

500

1000

2000

4000

10

8000

17

19

14

Table of correction factors for the calculation of the


sound power level spectrum.

200

108

108

107

104

107

100
0
5000

10000
2

15000

20000

25000
6

30000

35000
9

40000 qv [m3/h]

10

11

qv [m3/s]

P [W ]
20000
18000

32

16000

30
28

14000

26
24

12000

22

10000

20

8000
6000
4000

2000
5000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

Cylindrical cased axial ow fans THGT

10000

15000

10

12

14

20000

25000

VSD* SR* d[%]*

PM* MC*

EC*

5,5

Total

No

10

5,5

Total

No

12

5,5

Total

No

14

7,5

Total

16

7,5

18

11

20

11

22

16

18

30000

35000

[m3/h]

40000 qv [m3/h]

N*

[kW]

[Pa] [RPM]

48,8

51,0

4,593

9830

821

2953

50,3

52,1

5,180

12340

760

2948

53,7

55,0

6,248

11159

1091

2932

No

55,9

57,0

6,843

15500

889

2948

Total

No

56,9

57,6

7,863

17380

929

2936

Total

No

57,9

58,3

8,858

20032

922

2926

Total

No

56,0

56,0

10,656

23527

905

2961

11

Total

No

55,9

55,8

12,261

25488

964

2954

24

15

Total

No

56,0

55,8

13,540

26643

1021

2964

26

15

Total

No

55,7

55,5

14,962

28197

1059

2958

28

15

Total

No

54,5

54,2

16,843

30173

1091

2946

30

18,5

Total

No

54,3

53,9

18,525

30007

1205

2954

32

18,5

Total

No

52,7

52,2

20,212

31178

1230

2949

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 4 POLE MOTORS - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

THGT F200 - F300 - F400


Number of poles

160

Number of blades

36
34
32
30
120

20
18

400

60

THGT/4-400-6/_-_KW

40

63

38

38

31

125

22

21

19

20

250

12

12

500

1000

2000

4000

13

14

11

P [W ]

8000

21

23

19

350

Table of correction factors for the calculation of the


sound power level spectrum.

71

100

80

8 1012 1416

140

Nominal diameter (mm)

Hz

psf
[Pa]

74

0.2

0.3

75

0.4

2000
0.5

2500

0.6

0.7

76

74

75

77

1500

75

75

78

74

1000

28

78

81

B
A

0
500

22 24

74

74

74

3000
0.8

3500
0.9

75dB(A) [LwA]

4000
1.1

75

4500
1.2

5000 qv [m3 /h]

1.3

300

qv [m3/s]

36
34

250

32
30

200

28
150

22
100
50

8
0
500

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

www.solerpalau.com

1000

12

10

1500

16

14

2000

2500

18

3000

VSD* SR* d[%]*

24

20

3500

4000

N*

[kW]

[m3/h]

4500

PM* MC*

EC*

0,55

Total

No

41,3

55,6

0,054

880

[Pa] [RPM]
90

1493

10

0,55

Total

No

47,0

60,6

0,071

989

122

1491

12

0,55

Total

No

40,6

53,3

0,096

1131

124

1489

14

0,55

Total

No

41,4

53,8

0,110

1326

123

1488

16

0,55

Total

No

43,0

55,2

0,117

1972

91

1487

18

0,55

Total

No

44,8

56,6

0,137

2211

99

1485

20

0,55

Total

No

45,7

57,0

0,162

2350

113

1483

22

0,55

Total

No

46,3

57,2

0,187

2619

118

1480

24

0,55

Total

No

46,2

56,8

0,214

2816

126

1478

28

0,55

Total

No

42,9

53,0

0,254

3120

125

1473

30

0,55

Total

No

42,8

52,7

0,276

3370

125

1471

32

0,55

Total

No

42,0

51,6

0,304

3527

130

1468

34

0,55

Total

No

41,2

50,5

0,335

3726

133

1465

36

0,55

Total

No

41,4

50,4

0,374

3839

145

1460

Cylindrical cased axial ow fans THGT

5000 qv [m3 /h]

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 4 POLE MOTORS - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf
[Pa]

180

10 14
8 12 16

343638
32
30
28
26
24

160

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

140

75
100

THGT F200 - F300 - F400


Number of poles

Nominal diameter (mm)


Number of blades

80

80

79

B
78

82

78

78

78

79dB(A) [LwA]

60

40
63

79

450

THGT/4-450-6/_-_ kW
Hz

22
20
84 18
81

120

38

38

31

125

22

21

19

250

12

12

500

1000

2000

4000

13

14

11

8000

21

23

19

Table of correction factors for the calculation of the


sound power level spectrum.

20

A
78

0
1000

80

2000
0.4

78

3000

0.6

0.8

4000
1

78

78

5000

1.2

6000

1.4

79

7000

1.6

1.8

8000 qv [m3/h]

2.2

qv [m3/s]

P [W ]
700

38

600

36
34

500

32

400

30
28

300
200

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

Cylindrical cased axial ow fans THGT

14
10 12

100
1000

16 18

2000

3000

PM* MC*

EC*

0,55

Total

No

10

0,55

Total

No

12

0,55

Total

14

0,55

16

0,55

18

0,55

20

20

4000

22

5000

VSD* SR* d[%]*

24

26

6000

7000

8000 qv [m3/h]

N*

[kW]

[m3/h]

34,0

45,6

0,146

1297

138

1484

35,1

46,2

0,173

1516

144

1482

No

36,2

46,9

0,203

1664

159

1479

Total

No

36,6

47,0

0,223

1908

154

1477

Total

No

37,7

48,1

0,223

2873

105

1477

Total

No

40,4

50,5

0,255

3195

116

1473

0,55

Total

No

42,7

52,4

0,290

3546

125

1470

22

0,55

Total

No

44,1

53,5

0,331

3830

137

1465

24

0,55

Total

No

47,9

57,0

0,366

4192

150

1461

26

0,55

Total

No

48,6

57,4

0,399

4506

154

1457

28

0,55

Total

No

47,6

56,2

0,442

4872

154

1452

30

0,55

Total

No

47,6

56,0

0,478

5064

161

1448

32

0,55

Total

No

44,1

52,0

0,573

5358

169

1449

34

0,55

Total

No

44,1

51,8

0,613

5559

175

1446

36

0,55

Total

No

43,5

51,0

0,654

5813

176

1442

38

0,55

Total

No

41,9

49,2

0,703

6068

174

1437

[Pa] [RPM]

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 4 POLE MOTORS - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

psf
[Pa]

16
14 18
240

200

34
3032
28
26
24
22
20
84
82

160

87
THGT F200 - F300 - F400
Number of poles

120

Nominal diameter (mm)


Number of blades

500
6

80
THGT/4-500-6/_-_ kW
Hz
63

38

38

31

125

22

21

19

250

12

12

500

1000

2000

4000

13

14

11

8000

21

23

19

Table of correction factors for the calculation of the


sound power level spectrum.

40

B
A

84

3000
0.5

82

81

83
0
1000

36

81

83dB(A) [LwA]

82

81

5000

83

81

81

7000

1.5

83

9000

11000 qv [m3/h]

2.5

qv [m3/s]

P [W ]

1000

36
34

800

32
30
600

28

400

14 16
200
1000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

www.solerpalau.com

3000

18

5000

20

22

24

26

7000

VSD* SR* d[%]*

9000

11000 qv [m3/h]

N*

[kW]

[m3/h]

38,4

47,5

0,366

3686

137

1472

41,7

50,5

0,411

4187

147

1467

No

44,7

53,2

0,457

4629

159

1462

Total

No

46,4

54,6

0,507

5143

164

1458

Total

No

47,4

55,3

0,568

5504

176

1451

Total

No

48,7

56,4

0,613

6026

177

1446

0,55

Total

No

48,5

55,9

0,678

6292

187

1439

28

0,75

Total

No

48,7

55,8

0,757

6826

194

1451

30

0,75

Total

No

48,9

55,8

0,808

7361

192

1446

32

0,75

Total

No

48,2

54,9

0,867

7795

192

1440

34

0,75

Total

No

47,8

54,3

0,956

7872

209

1433

36

1,1

Total

No

48,2

54,4

1,050

8445

215

1455

PM* MC*

EC*

14

0,55

Total

No

16

0,55

Total

No

18

0,55

Total

20

0,55

22

0,55

24

0,55

26

[Pa] [RPM]

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 4 POLE MOTORS - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

psf
[Pa]

280

240

90
160

Nominal diameter (mm)


Number of blades

120

560

26

34
32
30
28

87

36
38

85

86

87

85

87

84

84

85

87dB(A) [LwA]

80

THGT/4-560-6/_-_ kW
Hz

24
20 22

200

THGT F200 - F300 - F400


Number of poles

12 16
101418

63

38

38

31

125

22

21

19

250

12

12

500

1000

2000

4000

13

14

11

8000

21

23

19

Table of correction factors for the calculation of the


sound power level spectrum.

40

0
2000

85

4000

86

6000

1.5

84

8000
2

10000
2.5

84

85

12000

14000

16000 qv [m3/h]

qv [m3/s]

86

3.5

P [W ]

1800

38
36
34

1400

32
30
28

1000

26
24
600

14
10 12
200
2000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

Cylindrical cased axial ow fans THGT

4000

6000

PM* MC*

EC*

10

0,55

Total

No

12

0,55

Total

No

14

0,55

Total

16

0,55

18

0,55

20

0,75

22

16 18

8000

20

22

10000

VSD* SR* d[%]*

12000

14000

16000 qv [m3/h]

N*

[kW]

[m3/h]

38,6

47,0

0,476

3532

187

1461

40,3

48,5

0,510

4609

160

1457

No

43,2

51,1

0,570

5595

158

1452

Total

No

46,2

53,8

0,632

6204

169

1442

Total

No

48,0

55,3

0,712

7138

171

1436

Total

No

50,1

57,0

0,810

7717

188

1448

0,75

Total

No

51,0

57,6

0,901

8416

195

1440

24

1,1

Total

No

54,5

60,7

1,065

9145

227

1454

26

1,1

Total

No

54,4

60,3

1,182

9418

245

1449

28

1,1

Total

No

54,7

60,4

1,275

10229

245

1443

30

1,1

Total

No

54,6

60,1

1,375

10490

258

1438

32

1,1

Total

No

52,4

57,5

1,549

10473

279

1444

34

1,5

Total

No

52,6

57,6

1,622

12053

254

1438

36

1,5

Total

No

50,7

55,4

1,789

11718

278

1431

38

2,2

Total

No

51,0

55,5

1,947

12224

293

1461

[Pa] [RPM]

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 4 POLE MOTORS - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

psf
[Pa]

10 14
8 12 1618

350

300

34
30

250

200
THGT F200 - F300 - F400
Number of poles

93

90

88

90

91

Nominal diameter (mm)


Number of blades

150

630

89

63

38

38

31

125

22

21

19

250

12

12

500

1000

2000

4000

13

14

11

8000

21

23

19

Table of correction factors for the calculation of the


sound power level spectrum.

91

87

87

90dB(A) [LwA]

89

100

THGT/4-630-6/_-_ kW
Hz

87

36
38

28
26
24
22
20

50

89

89

87

87

89

90

0
0

4000

8000

12000

16000
4

20000
5

24000 qv [m3/h]
6

qv [m3/s]

P [W ]

38
36

3200
2800

34

2400

30

2000

28
1600

26
24

1200

22
20

800

400
0

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

www.solerpalau.com

4000

10 12

8000

14

16 18

12000

VSD* SR* d[%]*

16000

20000

24000 qv [m3/h]

N*

[kW]

[m3/h]

41,7

49,2

0,655

4649

212

1458

44,9

52,1

0,730

6353

185

1452

No

47,0

54,0

0,793

7441

181

1446

Total

No

50,0

56,5

0,926

8402

198

1437

Total

No

55,5

61,7

1,039

9800

212

1455

Total

No

56,9

62,8

1,171

10385

231

1448

1,1

Total

No

58,2

63,7

1,346

11193

252

1440

22

1,5

Total

No

59,1

64,3

1,535

12264

265

1443

24

1,5

Total

No

58,6

63,4

1,731

13578

268

1431

26

2,2

Total

No

58,9

63,4

1,927

14076

290

1459

28

2,2

Total

No

58,1

62,3

2,182

14920

305

1454

30

2,2

Total

No

58,9

62,7

2,487

16522

318

1449

34

Total

No

55,7

59,1

2,962

17466

339

1461

36

Total

No

56,4

59,5

3,230

18369

356

1458

38

Total

No

55,2

58,1

3,488

19046

364

1453

PM* MC*

EC*

0,75

Total

No

10

0,75

Total

No

12

0,75

Total

14

0,75

16

1,1

18

1,1

20

[Pa] [RPM]

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 4 POLE MOTORS - THGT F200 - F300
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

psf

12
8101416

[Pa]

280

240

24
26

200

160
THGT F200 - F300
Number of poles

89

93

91

28 32
90 30 92

Nominal diameter (mm)


Number of blades

120

710

92

63

22

20

18

125

19

19

17

250

13

11

12

500

1000

2000

4000

11

13

12

8000

18

20

20

Table of correction factors for the calculation of the


sound power level spectrum.

91

80

THGT/4-710-3/_-_ kW
Hz

18 20 22

40

92

91dB(A) [LwA]

89

88

90

88

89

91

0
0

4000

8000

12000
3

16000
4

20000
5

24000
6

28000 qv [m3/h]

qv [m3/s]

P [W ]

32
30

2400

28
2000

26
1600

24
20

1200

22

18
800

12
8

14

16

10

400
0

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

Cylindrical cased axial ow fans THGT

4000

8000

12000

PM* MC*

EC*

0,75

Total

No

10

0,75

Total

No

12

0,75

Total

14

1,1

16

1,1

18

1,1

20

16000

VSD* SR* d[%]*

20000

24000

28000 qv [m3/h]

N*

[kW]

[m3/h]

54,5

61,8

0,683

9540

140

1452

56,4

63,5

0,760

10730

144

1444

No

57,5

64,2

0,885

12403

147

1433

Total

No

59,9

66,2

1,015

13792

158

1456

Total

No

63,0

69,2

1,068

15253

158

1452

Total

No

63,0

68,8

1,231

15796

176

1444

1,5

Total

No

61,1

66,5

1,401

16402

188

1446

22

1,5

Total

No

62,0

67,2

1,535

19083

179

1443

24

1,5

Total

No

61,0

65,8

1,762

19188

202

1430

26

2,2

Total

No

62,0

66,4

2,011

19688

228

1458

28

2,2

Total

No

60,6

64,7

2,242

21146

231

1451

30

Total

No

61,9

65,7

2,486

22414

247

1466

32

Total

No

59,5

63,1

2,712

22645

257

1461

[Pa] [RPM]

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 4 POLE MOTORS - THGT F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

THGT F400

10 14
8 12 1618

400

350

28
26

250

90

Number of blades

710

150

THGT/4-710-5/_-_ kW

100

63

38

38

31

125

22

21

19

250

12

12

500

1000

2000

4000

13

14

11

8000

21

23

19

Table of correction factors for the calculation of the


sound power level spectrum.

95

B
A

Nominal diameter (mm)

32 34
30

38

22 24
20

300

200

Number of poles

Hz

psf
[Pa]

50

92

93

92

93

93

90

92

93

94

91

92

90

94dB(A) [LwA]

91

92

0
0

4000

8000

12000

16000

20000
5

24000
6

qv [m3/s]

5000

38

4500
4000

34
32
30

2500

28
26

2000
1500
1000

12
8 10

500
0

www.solerpalau.com

32000 qv [m3/h]

P [W ]

3000

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

28000

3500

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

94

4000

8000

12000

14 16

16000

VSD* SR* d[%]*

22
20
18

24

20000

24000

28000

N*

[kW]

[m3/h]

43,6

50,4

0,841

6075

217

1465

46,9

53,3

0,980

7820

212

1457

No

50,3

56,3

1,146

9705

214

1451

Total

No

52,7

58,3

1,291

10547

233

1443

Total

No

53,2

58,4

1,502

11693

246

1446

Total

No

55,5

60,4

1,715

13691

250

1438

2,2

Total

No

57,3

61,8

1,969

14407

282

1460

22

2,2

Total

No

58,2

62,4

2,207

15122

306

1453

24

2,2

Total

No

58,2

62,0

2,515

16478

320

1443

26

Total

No

59,4

62,9

2,849

18799

323

1462

28

Total

No

58,4

61,6

3,183

19253

347

1458

30

Total

No

57,5

60,3

3,577

20137

368

1450

32

Total

No

55,5

58,1

3,972

20388

389

1458

34

5,5

Total

No

57,4

59,7

4,306

23946

371

1472

38

5,5

Total

No

54,8

56,7

4,983

27964

352

1472

PM* MC*

EC*

1,1

Total

No

10

1,1

Total

No

12

1,1

Total

14

1,1

16

1,5

18

1,5

20

32000 qv [m3/h]

[Pa] [RPM]

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 4 POLE MOTORS - THGT F200 - F300
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

psf
[Pa]

1012
14
8

440
400
360
320

30
24 2628 32
22
1618
20

280

91

240

B
A

THGT F200 - F300


Number of poles

200

Nominal diameter (mm)


Number of blades

710

160

120

THGT/4-710-6/_-_ kW
Hz

63

38

38

31

125

22

21

19

250

12

12

500

1000

2000

4000

13

14

11

8000

21

23

19

Table of correction factors for the calculation of the


sound power level spectrum.

96

80
40

92

93

93

94

91

92

93

93dB(A) [LwA]

91

93

91

91

92

0
0

4000

8000

12000

16000

20000
5

24000
6

28000

32000 qv [m3/h]

qv [m3/s]

P [W ]

32

4000
3500

30

3000

28
26

2500

24
22

2000

20
18

1500

12

1000

14

16

8 10

500
0

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

Cylindrical cased axial ow fans THGT

4000

8000

PM* MC*

EC*

12000

16000

VSD* SR* d[%]*

20000

24000

N*

[kW]

[m3/h]

28000

32000 qv [m3/h]

[Pa] [RPM]

1,1

Total

No

53,5

59,7

1,049

8522

237

1454

10

1,1

Total

No

55,6

61,4

1,203

10188

236

1444

12

1,5

Total

No

55,1

60,4

1,461

12065

240

1445

14

1,5

Total

No

58,9

64,0

1,581

13769

242

1438

16

1,5

Total

No

58,6

63,3

1,786

14239

265

1428

18

2,2

Total

No

58,7

62,9

2,137

16378

275

1455

20

2,2

Total

No

63,3

67,3

2,337

18160

292

1447

22

Total

No

64,4

68,1

2,659

19780

311

1464

24

Total

No

62,7

66,2

2,826

21038

302

1457

26

Total

No

63,6

66,8

3,152

22501

320

1452

28

Total

No

62,6

65,6

3,349

23573

320

1449

30

Total

No

60,8

63,4

3,867

25107

337

1456

32

Total

No

59,6

62,0

4,246

25990

350

1449

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 4 POLE MOTORS - THGT F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

THGT

psf

12 16
81014 18

[Pa]

400

36
34
32
30
28

350

22
20

250

B
A

Nominal diameter (mm)


Number of blades

710

150

THGT/4-710-7/_-_kW
Hz

100

63

38

38

31

125

22

21

19

250

12

12

500

1000

2000

4000

13

14

11

8000

21

23

19

Table of correction factors for the calculation of the


sound power level spectrum.

97

91

200

Number of poles

24
300

50

92

94

94

95

94

91

94

91

93

95

93

91

91

94dB(A) [LwA]

93

94

0
0

4000

8000

12000

16000

20000
5

24000
6

28000

32000 qv [m3/h]

qv [m3/s]

P [W ]
5000

36
34

4000

32
30

3000

28
24

2000

12
8 10

1000

14

16

18

20

22

0
0

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

www.solerpalau.com

4000

8000

12000

16000

VSD* SR* d[%]*

20000

24000

28000

N*

[kW]

[m3/h]

40,1

46,1

1,125

5676

285

1451

41,7

47,4

1,273

6436

296

1445

No

43,0

48,4

1,403

8153

266

1449

Total

No

44,6

49,8

1,527

10291

238

1444

Total

No

47,2

52,0

1,757

11597

258

1434

Total

No

49,4

53,8

1,987

12661

279

1421

2,2

Total

No

53,0

57,1

2,285

14331

304

1454

22

Total

No

54,4

58,0

2,674

16099

324

1467

24

Total

No

56,1

59,3

3,084

17599

352

1456

28

Total

No

54,1

56,8

3,694

19053

377

1449

30

Total

No

54,5

56,9

4,253

20957

397

1454

32

Total

No

54,6

56,7

4,651

21372

428

1449

34

5,5

Total

No

55,4

57,3

5,036

23818

420

1468

36

5,5

Total

No

54,8

56,4

5,597

24149

456

1466

PM* MC*

EC*

1,1

Total

No

10

1,1

Total

No

12

1,5

Total

14

1,5

16

1,5

18

1,5

20

32000 qv [m3/h]

[Pa] [RPM]

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 4 POLE MOTORS - THGT F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf
[Pa]

1216
81014 18

350

28

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

93

63

96
100

22

20

18

125

19

19

17

250

13

11

12

500

1000

2000

4000

11

13

12

8000

18

94

94

96

150

800

THGT/4-800-3/_-_ kW
Hz

96

Number of blades

250

200

Nominal diameter (mm)

32

2426
22
20

300

THGT F400
Number of poles

30

20

20

Table of correction factors for the calculation of the


sound power level spectrum.

94

92

93

95dB(A) [LwA]

93

92

93

95

20000

25000

30000

35000

50

96
0
0

5000
1

10000
2

15000
4

40000 qv [m3/h]

10

11

qv [m3/s]

P [W ]
4500

32
4000

30
3500

28

3000

26
24

2500

22

2000
1500
1000

10

14
12

20
18
16

500
0

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

Cylindrical cased axial ow fans THGT

5000

10000

PM* MC*

EC*

15000

20000

VSD* SR* d[%]*

25000

30000

N*

[kW]

[m3/h]

35000

40000 qv [m3/h]

[Pa] [RPM]

1,1

Total

No

48,0

54,6

0,916

8847

179

1460

10

1,1

Total

No

52,1

58,2

1,101

11120

186

1452

12

1,1

Total

No

53,9

59,5

1,308

13203

193

1441

14

1,5

Total

No

54,1

59,3

1,512

13959

212

1445

16

1,5

Total

No

56,0

60,8

1,725

15967

218

1433

18

2,2

Total

No

57,8

62,2

2,028

17678

239

1456

20

2,2

Total

No

57,1

61,2

2,289

17505

269

1450

22

Total

No

57,8

61,4

2,744

19510

293

1464

24

Total

No

56,9

60,2

3,044

19992

313

1458

26

Total

No

55,9

58,9

3,374

21680

314

1455

28

Total

No

54,6

57,2

3,832

23514

321

1458

30

5,5

Total

No

56,9

59,3

4,200

25599

336

1476

32

5,5

Total

No

56,1

58,2

4,666

29911

315

1473

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 4 POLE MOTORS - THGT F200 - F300
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

psf

10 14
8 12 16

[Pa]

280

240

20 22

200

Number of blades

120

800

94

96

32
96

94

22

20

18

125

19

19

17

250

13

11

12

500

1000

2000

4000

11

13

12

8000

18

20

20

Table of correction factors for the calculation of the


sound power level spectrum.

92

94

93

95dB(A) [LwA]

80

THGT/4-800-3/_-_ kW

63

96

30

Nominal diameter (mm)

Hz

93

160
THGT F200 - F300
Number of poles

2628

18

40

96

93

92

93

95

30000

35000

0
0

5000
1

10000
2

15000

20000

25000

40000 qv [m3/h]

10

11

qv [m3/s]

P [W ]

32

4000

30

3500

28

3000

26

2500

22

2000

18

1500

20

16

1000

14
12
10

500
0

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

www.solerpalau.com

5000

10000

PM* MC*

EC*

15000

20000

VSD* SR* d[%]*

25000

30000

35000

40000 qv [m3/h]

N*

[kW]

[m3/h]

[Pa] [RPM]

1,1

Total

No

58,6

64,9

1,026

14310

151

1454

10

1,1

Total

No

61,5

67,4

1,169

16052

161

1448

12

1,5

Total

No

62,9

68,4

1,339

17410

174

1448

14

1,5

Total

No

61,7

67,0

1,477

18576

176

1441

16

2,2

Total

No

61,7

66,6

1,672

21159

175

1431

18

Total

No

60,3

64,7

2,054

23234

192

1455

20

Total

No

64,0

68,0

2,321

24379

219

1467

22

Total

No

62,9

66,6

2,571

25631

227

1464

26

Total

No

58,2

61,3

3,208

25203

267

1453

28

Total

No

60,2

63,0

3,609

29333

267

1461

30

Total

No

57,5

60,0

4,034

29826

280

1455

32

5,5

Total

No

60,8

63,1

4,386

31988

301

1472

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 4 POLE MOTORS - THGT F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf
[Pa]

500

10121416

450

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

30
28
26

400

24
22
18 20

350

300
THGT F400

250

Number of poles

Nominal diameter (mm)


Number of blades

95

99

200

800

32

96

97

96

97

94

97

95

96dB(A) [LwA]

150

THGT/4-800-6/_-_ kW
Hz

63

38

38

31

125

22

21

19

250

12

12

500

1000

2000

4000

13

14

11

8000

21

23

19

Table of correction factors for the calculation of the


sound power level spectrum.

100

50

97

96

94

95

96

0
0

5000
1

10000
2

15000

20000

25000

30000
8

35000
9

40000 qv [m3/h]

10

11

qv [m3/s]

P [W ]
7000

32
6000

30
5000

28
26

4000

24
22

3000
2000

8 10

1000
0

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

Cylindrical cased axial ow fans THGT

5000

10000

PM* MC*

EC*

15000

12

14

20000

VSD* SR* d[%]*

20
18
16

25000

30000

N*

[kW]

[m3/h]

35000

40000 qv [m3/h]

[Pa] [RPM]

1,5

Total

No

42,9

48,0

1,555

7990

301

1442

10

1,5

Total

No

44,4

49,1

1,809

9588

302

1430

12

2,2

Total

No

50,4

54,7

2,118

13514

284

1457

14

2,2

Total

No

52,3

56,3

2,375

15388

291

1450

16

Total

No

55,6

59,0

2,945

18078

326

1456

18

Total

No

56,7

59,9

3,174

19094

339

1455

20

Total

No

56,2

59,1

3,499

21844

322

1450

22

Total

No

57,5

59,9

4,267

23366

377

1455

24

5,5

Total

No

60,9

62,9

4,791

25745

405

1469

26

5,5

Total

No

60,1

61,9

5,311

26241

437

1468

28

5,5

Total

No

59,2

60,7

5,918

28243

445

1462

30

7,5

Total

No

58,7

59,8

6,649

29304

479

1473

32

7,5

Total

No

58,5

59,4

7,167

30498

494

1473

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 4 POLE MOTORS - THGT F200 - F300
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf
[Pa]

8101214

450

400

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

350

24
16

300

Nominal diameter (mm)


Number of blades

200

96

97

800

97

97

94

95

96dB(A) [LwA]

150

THGT/4-800-6/_-_ kW

100
Hz

96

250
THGT F200 - F300
Number of poles

99

95

32

262830

20 22
18

63

38

38

31

125

22

21

19

250

12

12

500

1000

2000

4000

13

14

11

8000

21

23

19

Table of correction factors for the calculation of the


sound power level spectrum.

50

97

96

94

95

96

30000

35000

40000

0
0

5000
1

10000
2

15000

20000
5

25000

10

11

45000 qv [m3/h]
12

qv [m3/s]

P [W ]

32

7000

30

6000

28
5000

26
24
22

4000

20
18

3000
2000

12

10

16
14

1000
0

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

www.solerpalau.com

5000

10000

15000

20000

25000

VSD* SR* d[%]*

30000

35000

40000

45000 qv [m3/h]

N*

[kW]

[m3/h]

[Pa] [RPM]

53,4

58,3

1,658

13339

239

1434

59,2

63,7

1,956

15603

267

1458

No

60,5

64,6

2,251

18276

267

1449

Total

No

60,7

64,2

2,788

20610

296

1462

Total

No

64,3

67,6

3,016

22820

304

1456

Total

No

64,4

67,3

3,477

24957

322

1446

Total

No

64,7

67,3

3,963

26584

345

1456

22

Total

No

64,4

66,7

4,373

27949

361

1449

24

5,5

Total

No

67,0

69,0

4,812

29373

397

1468

26

5,5

Total

No

63,3

65,0

5,389

31644

387

1466

28

7,5

Total

No

64,2

65,6

6,075

33061

425

1475

30

7,5

Total

No

63,2

64,3

6,683

34155

445

1473

32

7,5

Total

No

62,5

63,4

7,272

34496

475

1469

PM* MC*

EC*

1,5

Total

No

10

2,2

Total

No

12

2,2

Total

14

16

18

20

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 4 POLE MOTORS - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

psf
[Pa]

12
500

400

300
4

Nominal diameter (mm)


Number of blades

22

800

63

40

38

32

125

26

19

19

250

14

11

500

1000

2000

4000

12

13

10

8000

20

21

17

Table of correction factors for the calculation of the


sound power level spectrum.

32

99

96

99

200

30
28
26
24

98dB(A) [LwA]

B
95

THGT/4-800-9/_-_ kW
Hz

20

101

THGT F200 - F300 - F400


Number of poles

1416
18

100

0
5000

98

10000
2

15000

95

97

95

20000
5

95

25000
6

30000

97

35000
9

40000 qv [m3/h]

10

11

qv [m3/s]

P [W ]
9000
8000

32

7000

30

6000

28
5000

26
24

4000

22
20

3000
2000
5000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

Cylindrical cased axial ow fans THGT

12 14
10000

15000

16

20000

18
25000

VSD* SR* d[%]*

30000

35000

40000 qv [m3/h]

N*

[kW]

[m3/h]

[Pa] [RPM]

41,6

45,1

2,810

10603

398

1437

43,7

47,0

2,995

14613

322

1454

No

46,2

49,2

3,378

16701

336

1453

Total

No

48,8

51,4

3,836

18491

364

1444

Total

No

50,4

52,6

4,474

20727

390

1449

Total

No

55,7

57,6

5,060

22808

441

1470

5,5

Total

No

55,7

57,3

5,540

24397

453

1465

26

5,5

Total

No

56,5

57,7

6,539

26631

497

1460

28

7,5

Total

No

55,2

56,2

7,087

28639

491

1473

30

7,5

Total

No

56,4

57,1

7,946

31203

514

1471

32

7,5

Total

No

56,3

56,6

9,005

32306

563

1465

PM* MC*

EC*

12

2,2

Total

No

14

Total

No

16

Total

18

20

22

5,5

24

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 4 POLE MOTORS - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf
[Pa]

810121416

400

32
28

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

THGT F200 - F300 - F400


Number of poles

Number of blades

97

250

200

100

900

97

97

100

96

99dB(A) [LwA]

95

150

THGT/4-900-3/_-_kW

63

26
24
22
20
100 18
97

300

Nominal diameter (mm)

Hz

350

100

22

20

18

125

19

19

17

250

13

11

12

500

1000

2000

4000

11

13

12

8000

18

20

20

Table of correction factors for the calculation of the


sound power level spectrum.

50

100

96

96

95

99

0
0

5000
1

10000
2

15000
4

20000
5

25000

30000
8

35000
9

40000

10

11

45000
12

50000 qv [m3/h]

13

qv [m3/s]

P [W ]

32

7000
6000

28
26

5000

24
4000

22
20

3000

18
14

2000

1000
0

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

www.solerpalau.com

5000

10000

15000

20000

10

25000

VSD* SR* d[%]*

16

12
30000

35000

40000

45000

N*

[kW]

[m3/h]

[Pa]

50,0

55,2

1,511

14820

183

1472

53,5

58,3

1,762

17192

197

1463

No

56,6

60,9

2,074

19562

216

1459

No

57,2

61,0

2,532

21964

238

1465

Total

No

57,8

61,2

2,954

23780

259

1460

Total

No

57,7

60,6

3,437

25721

277

1466

Total

No

56,4

59,0

3,951

27968

287

1460

Total

No

56,2

58,4

4,500

29133

313

1453

24

5,5

Total

No

57,8

59,7

4,983

32341

320

1471

26

5,5

Total

No

56,5

58,1

5,593

32754

347

1466

28

7,5

Total

No

60,5

61,8

6,189

34125

395

1477

32

7,5

Total

No

57,1

58,0

7,315

39749

378

1471

PM* MC*

EC*

2,2

Total

No

10

2,2

Total

No

12

2,2

Total

14

Total

16

18

20

22

50000 qv [m3/h]

[RPM]

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 4 POLE MOTORS - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

psf
[Pa]

10121416
18
700 8

600

30
500

20

B
A

400
THGT F200 - F300 - F400
Number of poles

Nominal diameter (mm)


Number of blades

300

900
6

200

THGT/4-900-6/_-_ kW
Hz

63

38

38

31

125

22

21

19

250

12

12

500

1000

2000

4000

13

14

11

8000

21

23

19

Table of correction factors for the calculation of the


sound power level spectrum.

100

99

22

24

103

26

99

101

28

101

99

100

97

101

99

20000

30000

98

100dB(A) [LwA]

98

97

100

0
0

10000
1

40000

11

50000
13

60000 qv [m3/h]
15

qv [m3/s]

P [W ]

10000

30
28

8000

26
24

6000

22
20
18

4000

16
14
0

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Static pressure
Speed

Cylindrical cased axial ow fans THGT

10 12

2000
10000
PM* MC*

20000
EC*

30000

VSD* SR* d[%]*

40000

50000

60000 qv [m3/h]

N*

[kW]

[m3/h]

[Pa] [RPM]

Total

No

44,9

48,6

2,639

12369

345

1463

10

Total

No

47,9

51,2

3,061

16697

316

1457

12

Total

No

49,0

52,0

3,420

19042

317

1451

14

Total

No

51,5

53,9

4,164

23235

332

1454

16

Total

No

53,2

55,3

4,657

27330

325

1452

18

5,5

Total

No

56,9

58,7

5,236

30652

347

1470

20

7,5

Total

No

62,6

63,8

6,401

32240

448

1478

22

7,5

Total

No

65,1

66,0

7,227

35512

477

1469

24

11

Total

No

63,9

64,5

8,127

36949

506

1484

26

11

Total

No

67,1

67,3

9,388

39425

575

1483

28

11

Total

No

64,2

64,3

10,254

40783

580

1479

30

11

Total

No

63,3

63,3

11,605

43227

612

1476

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 4 POLE MOTORS - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

psf
[Pa]

14
12 16

600

18
500

28
26
24

22
20

THGT F200 - F300 - F400

300

Nominal diameter (mm)


Number of blades

900
9

200
THGT/4-900-9/_-_ kW
Hz

63

40

38

32

125

26

29

29

250

24

11

500

1000

2000

4000

12

13

10

8000

20

21

17

Table of correction factors for the calculation of the


sound power level spectrum.

400

104

Number of poles

32
30

100

101

B
A

0
10000

102

98

99

101

20000
3

102 dB(A) [LwA]

100

99

98

30000

40000

101

101

50000
11

60000 qv [m3/h]

13

15

qv [m3/s]

P [W ]
14000

32
30

12000

28

10000

26
8000

24
22

6000

20

4000

12
2000
10000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Static pressure
Speed

www.solerpalau.com

20000

14

16

18

30000

40000

VSD* SR* d[%]*

50000

60000 qv [m3/h]

N*

[kW]

[m3/h]

[Pa] [RPM]

43,6

45,7

4,694

18968

388

1474

45,6

47,5

4,963

22662

359

1470

No

48,5

50,0

5,781

26340

381

1465

Total

No

55,2

56,4

6,528

29399

442

1476

Total

No

56,9

57,8

7,276

31226

479

1474

Total

No

59,5

59,9

8,807

36015

524

1485

11

Total

No

62,6

62,6

9,904

38418

578

1482

26

11

Total

No

63,2

63,2

11,204

40774

623

1476

28

15

Total

No

60,3

60,2

12,373

44472

604

1483

30

15

Total

No

60,1

59,9

14,057

48152

631

1479

32

15

Total

No

62,2

62,0

15,111

50687

668

1475

PM* MC*

EC*

12

5,5

Total

No

14

5,5

Total

No

16

5,5

Total

18

7,5

20

7,5

22

11

24

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 4 POLE MOTORS - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf

8 12101416

[Pa]

30

400

20
18

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

THGT F200 - F300 - F400


Number of poles

Number of blades

63

101
300

102

100

101

103

98

100

250

200

103

100

102dB(A) [LwA]

1000

150

THGT/4-1000-3/_-_ kW
Hz

2426 28
22

350

Nominal diameter (mm)

32

100

22

20

18

125

19

19

17

250

13

11

12

500

1000

2000

4000

11

13

12

8000

18

20

20

Table of correction factors for the calculation of the


sound power level spectrum.

50

103

99

100

98

102

0
0

10000
1

20000

30000
7

40000

11

50000
13

60000
15

70000 qv [m3/h]

17

19

qv [m3/s]

P [W ]

32
11000

30
28
9000

26
24

7000

22
20

5000

18
16

3000

8 10

14
12

1000
0

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

Cylindrical cased axial ow fans THGT

10000

20000

30000

40000

PM* MC*

EC*

VSD* SR* d[%]*

Total

No

10

Total

No

12

Total

14

16

18

5,5

20

50000

60000

70000 qv [m3/h]

N*

[kW]

[m3/h]

[Pa] [RPM]

60,1

64,1

2,306

21339

234

1461

64,0

67,6

2,705

23546

265

1453

No

60,9

64,1

3,158

25769

269

1445

Total

No

61,4

64,0

3,866

28168

304

1457

Total

No

61,3

63,5

4,554

32580

308

1448

Total

No

64,4

66,1

5,482

38624

329

1476

5,5

Total

No

62,3

63,6

6,326

39247

361

1469

22

7,5

Total

No

63,1

64,1

6,889

37952

412

1471

24

7,5

Total

No

62,9

63,6

7,805

43138

410

1465

26

7,5

Total

No

61,7

62,1

8,618

45180

424

1460

28

11

Total

No

58,9

58,9

9,901

48190

436

1475

30

11

Total

No

60,8

60,8

10,489

53790

427

1475

32

11

Total

No

60,2

60,2

11,715

51652

491

1469

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 4 POLE MOTORS - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf 121416

[Pa]

32
600

30
28

10

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

8
500

400

102

105

26
20 22
24
18
102

102

104

THGT F200 - F300 - F400


Number of poles

300

Nominal diameter (mm)


Number of blades

105

103

100

101

104 dB(A) [LwA]

1000
6

200

THGT/4-1000-6/_-_ kW
Hz
63

38

38

31

125

22

21

19

250

12

12

500

1000

2000

4000

13

14

11

8000

21

23

19

Table of correction factors for the calculation of the


sound power level spectrum.

100

0
10000
3

105

20000
5

102

30000
7

40000

11

101

100

50000
13

60000
15

103

70000

17

19

80000 qv [m3/h]
21

qv [m3/s]

P [W ]

18000

32
30
28

14000

26
24

10000

22
20
18

6000

8 10
2000
10000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

www.solerpalau.com

12

14

20000

30000

40000

PM* MC*

EC*

VSD* SR* d[%]*

Total

No

10

Total

No

12

5,5

Total

14

7,5

16

7,5

18

11

20

16

50000

60000

70000

80000 qv [m3/h]

N*

[kW]

[m3/h]

[Pa] [RPM]

53,5

55,9

4,208

22032

367

1451

56,4

58,5

4,684

24054

395

1445

No

57,7

59,3

5,699

28352

418

1474

Total

No

62,5

63,8

6,360

33975

421

1474

Total

No

64,5

65,3

7,412

37265

461

1469

Total

No

68,3

68,7

8,801

40215

536

1478

11

Total

No

66,9

66,9

9,902

43479

548

1476

22

11

Total

No

67,1

67,1

11,216 49012

552

1470

24

11

Total

No

66,0

65,9

12,726 50974

594

1466

26

15

Total

No

64,1

63,9

14,662 53641

632

1473

28

18,5

Total

No

65,4

65,1

16,138 61355

618

1488

30

18,5

Total

No

65,7

65,3

18,333 60204

720

1486

32

18,5

Total

No

67,5

67,0

19,838 64313

749

1481

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 4 POLE MOTORS - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

THGT F200 - F300 - F400


Number of poles

Number of blades

12

800

700

8
30

500

400

28

18 20

600

Nominal diameter (mm)

26
24

22
103

107

104

103

106

1000

106

300

THGT/4-1000-9/_-_ kW
Hz

psf

[Pa] 10 1416

200

63

40

38

32

125

26

19

19

250

14

11

500

1000

2000

4000

12

13

10

8000

20

21

17

Table of correction factors for the calculation of the


sound power level spectrum.

100

0
10000
3

106

20000
5

105

101

104

30000
7

11

104dB(A) [LwA]

102

101

40000

102

50000
13

60000
15

104

70000

17

19

80000 qv [m3/h]
21

qv [m3/s]

P [W ]
22000

30
18000

28
26

14000

24
22

10000

18

20

16
6000

8
2000
10000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

Cylindrical cased axial ow fans THGT

10

12

14

20000

30000

40000

50000

PM* MC*

EC*

VSD* SR* d[%]*

5,5

Total

No

10

7,5

Total

No

12

7,5

Total

14

7,5

16

11

18

11

20

60000

70000

80000 qv [m3/h]

N*

[kW]

[m3/h]

[Pa] [RPM]

48,4

50,0

5,621

17471

566

1476

50,5

51,8

6,307

22937

499

1473

No

54,2

55,1

7,143

29082

478

1468

Total

No

58,2

58,8

8,109

33922

500

1463

Total

No

61,2

61,3

9,600

38457

548

1476

Total

No

61,6

61,6

10,924 41569

582

1472

11

Total

No

63,1

63,0

12,025 44066

619

1468

22

15

Total

No

64,4

64,2

14,232 48312

682

1474

24

15

Total

No

65,9

65,6

15,949 55119

685

1470

26

18,5

Total

No

63,8

63,4

18,421 58461

724

1484

28

22

Total

No

66,7

66,2

20,209 61072

795

1480

301

22

Total

No

66,4

65,9

22,508 63755

844

1476

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 4 POLE MOTORS - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf
[Pa]

550

22 24 26
10 12 14 16

500

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

Number of poles

30 32

20

450

400

350
THGT F200 - F300 - F400

18

28

300

109

108

106

107

108

104

110 dB(A) [LwA]

Nominal diameter (mm)


Number of blades

1250

250

111

106

109

200

THGT/4-1250-3/_-_kW
Hz
63

22

20

18

125

19

19

17

250

13

11

12

150

100

111
50
10000

500

1000

2000

4000

11

13

12

P [W ]

8000

18

20

20

28000

Table of correction factors for the calculation of the


sound power level spectrum.

30000
7

106

50000
11

70000

15

19

106

104
90000

23

109

110000
27

130000 qv [m3/h]

31

35

qv [m3/s]

32
30
28

24000

26
20000

24
22

16000

20
18

12000

16
12

8000
4000
10000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

www.solerpalau.com

8
30000

50000

14

10
70000

VSD* SR* d[%]*

90000

110000

130000 qv [m3/h]

N*

[kW]

[m3/h]

[Pa] [RPM]

64,7

66,3

5,643

41588

317

1479

69,0

70,1

6,852

43258

395

1474

No

65,3

65,5

9,478

59981

371

1479

Total

No

67,8

67,8

10,609

62460

414

1472

Total

No

68,8

68,7

11,980

66314

447

1480

Total

No

68,9

68,7

13,570

71853

469

1478

15

Total

No

68,6

68,3

15,743

77165

505

1475

22

18,5

Total

No

72,0

71,7

16,943

77909

564

1479

24

22

Total

No

69,6

69,2

19,726

85581

580

1482

26

22

Total

No

68,6

68,1

21,699

89415

603

1478

28

30

Total

No

67,2

66,6

24,395

91319

650

1488

30

30

Total

No

67,4

66,7

26,756

96372

680

1485

32

30

Total

No

66,2

65,4

29,808 101860

708

1483

PM* MC*

EC*

7,5

Total

No

10

7,5

Total

No

12

11

Total

14

11

16

15

18

15

20

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 4 POLE MOTORS - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf
[Pa]

10 12 1416
8

800

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

700

600

500
THGT F200 - F300 - F40
Number of poles

Number of blades

108

109

300

38

31

125

22

21

19

250

12

12

500

1000

2000

4000

13

14

11

21

109

113

38

8000

111

111 dB(A) [LwA]

400

1250

THGT/4-1250-6/_-_ kW

63

110

Nominal diameter (mm)

Hz

28 30

18 20 22 24 26

23

19

Table of correction factors for the calculation of the


sound power level spectrum.

108

106

111

200

112
100
10000
3

30000
7

50000
11

108
70000

15

19

108

106

90000
23

110000
27

110

130000

31

35

150000 qv [m3/h]
39

qv [m3/s]

P [W ]
45000

30
28

40000
35000

26
24

30000

22

25000

20
20000

18
16

15000

14

10000

5000
10000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

Cylindrical cased axial ow fans THGT

10

30000

50000

12

70000

90000

110000

VSD* SR* d[%]*

N*

[kW]

[m3/h]

130000

PM* MC*

EC*

15

Total

No

61,6

61,7

10,315

43651

523

1485

10

15

Total

No

64,5

64,4

11,966

50747

548

1481

12

15

Total

No

67,1

66,9

14,097

58941

578

1477

14

18,5

Total

No

70,5

70,2

16,677

67521

626

1480

16

18,5

Total

No

71,3

70,9

19,295

75294

657

1477

18

22

Total

No

71,3

70,7

22,653

82062

708

1477

20

30

Total

No

71,9

71,2

25,918

87699

765

1486

22

30

Total

No

71,8

71,0

29,854

92880

831

1481

24

37

Total

No

70,6

69,7

33,705

96137

892

1487

26

37

Total

No

69,9

69,0

37,124

99982

936

1485

28

45

Total

No

66,5

65,4

43,879 105931

996

1486

30

45

Total

No

69,9

68,8

46,545 112731 1048

1485

150000 qv [m3/h]

[Pa] [RPM]

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 4 POLE MOTORS - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf
[Pa]

10 12 14 16

1100

8
1000

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

18

900

800

700
THGT F200 - F300 - F400
Number of poles

600

110

20 22 24

111

109 dB(A) [LwA]

108

Nominal diameter (mm)


Number of blades

1250

500

113

106

109

108

400

THGT/4-1250-9/_-_ kW
Hz
63

40

38

32

125

26

19

19

300

200

250

14

11

500

1000

2000

4000

12

13

10

P [W ]

8000

20

21

17

40000

Table of correction factors for the calculation of the


sound power level spectrum.

100
10000
3

112

30000
7

50000
11

108

70000

15

90000

19

108

106

23

110000
27

31

130000
35

150000 qv [m3/h]
39

qv [m3/s]

24
35000

22
30000

20
25000

18
16

20000

14
12

15000

10
8
10000
10000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

www.solerpalau.com

30000

50000

70000

90000

PM* MC*

EC*

VSD* SR* d[%]*

15

Total

No

10

18,5

Total

No

12

18,5

Total

14

22

16

30

18

30

20

110000

130000

150000 qv [m3/h]

N*

[kW]

[m3/h]

56,7

56,5

14,254

43369

671

1476

60,4

60,1

16,067

55232

632

1481

No

64,4

64,0

19,123

63274

701

1477

Total

No

66,6

66,1

21,199

69909

727

1478

Total

No

68,8

68,2

24,708

77013

793

1486

Total

No

68,9

68,2

27,794

83437

825

1483

30

Total

No

70,9

70,1

32,183

92260

888

1479

22

37

Total

No

70,7

69,8

37,421

97650

974

1485

24

45

Total

No

71,2

70,2

42,061 103105 1045

1484

[Pa] [RPM]

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 6 POLE MOTORS - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

psf
[Pa]

110

Number of poles

77
80

60

Number of blades

50

560
6

40

THGT/6-560-6/_-_ kW
Hz

30

63

33

33

28

125

18

15

18

250

10

500

1000

2000

10

4000

15

16

13

8000

23

25

21

Table of correction factors for the calculation of the


sound power level spectrum.

90

Nominal diameter (mm)

34
32
38
28 30
26
24
75
76
77
22
79
20
18 77

100

70
THGT F200 - F300 - F400

1214
16
10

120

20

B
A

75

10
0
1000

2000
1

3000
1.2

75

76

74

75

4000

5000

1.4

1.6

74

74

75

76dB(A) [LwA]

74

75

76

6000

7000

8000

9000

10000

11000 qv [m3/h]

2.2

2.4

2.6

2.8

1.8

qv [m3/s]

P [W ]

38
600

34
500

32
30

400

28
26

300

24

200

10
3000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

Cylindrical cased axial ow fans THGT

4000

12 14
5000

16

18

6000

VSD* SR* d[%]*

20

22

7000

8000

9000

10000

N*

[kW]

[m3/h]

34,2

45,2

0,179

2384

93

996

34,3

45,1

0,194

2956

81

994

No

37,0

47,6

0,212

3808

74

991

Total

No

39,0

49,3

0,236

4256

78

988

Total

No

41,4

51,3

0,269

4729

85

983

Total

No

43,4

53,0

0,303

5266

89

978

0,55

Total

No

44,7

54,0

0,332

5562

96

974

24

0,55

Total

No

43,7

52,7

0,372

5871

99

968

26

0,55

Total

No

45,6

54,5

0,389

6595

96

966

28

0,55

Total

No

43,4

52,0

0,440

6612

104

959

30

0,55

Total

No

44,0

52,4

0,470

7056

105

954

32

0,55

Total

No

41,5

49,7

0,503

7628

98

950

34

0,55

Total

No

40,6

48,3

0,616

7363

122

958

38

0,55

Total

No

40,7

48,0

0,695

8082

126

951

PM* MC*

EC*

10

0,55

Total

No

12

0,55

Total

No

14

0,55

Total

16

0,55

18

0,55

20

0,55

22

11000 qv [m3/h]

[Pa] [RPM]

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 6 POLE MOTORS - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf
[Pa]

140

1012
14
8

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

120

16
100

76

80
THGT F200 - F300 - F400
Number of poles

Nominal diameter (mm)


Number of blades

60

630
6

40

THGT/6-630-6/_-_ kW
Hz

63

33

33

28

125

18

15

18

250

10

500

1000

2000

10

4000

15

16

13

8000

23

25

21

Table of correction factors for the calculation of the


sound power level spectrum.

28
26
1820
2224

20

82

80

B
A
78

78
0
2000

79

80

4000
1

79

78

1.5

8000

80dB(A) [LwA]

79

78

81

78

78

6000

32 34 36 38
30

79

78

10000
2.5

12000
3

80

14000

16000 qv [m3/h]

qv [m3/s]

3.5

P [W ]
1000

38
36

800

34
30 32
28

600

26
24

400

12
8 10

200

2000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

www.solerpalau.com

4000

16

14

22
20

18

6000

8000

10000

PM* MC*

EC*

VSD* SR* d[%]*

0,55

Total

No

10

0,55

Total

No

12

0,55

Total

14

0,55

16

0,55

18

0,55

20

12000

14000

16000 qv [m3/h]

N*

[kW]

[m3/h]

34,8

45,1

0,238

3175

94

988

36,8

46,8

0,258

4115

83

985

No

39,6

49,3

0,293

4811

87

980

Total

No

40,8

50,2

0,332

5159

95

974

Total

No

44,3

53,3

0,371

6182

96

969

Total

No

45,0

53,7

0,419

7045

96

962

0,55

Total

No

45,8

54,2

0,472

7706

100

954

22

0,55

Total

No

45,6

53,7

0,522

8062

106

947

24

0,55

Total

No

45,5

53,3

0,587

8139

118

937

26

0,55

Total

No

44,6

52,0

0,683

8956

122

952

28

0,55

Total

No

44,6

51,8

0,741

9394

127

946

30

0,55

Total

No

44,7

51,6

0,810

9713

134

940

32

0,75

Total

No

49,9

56,8

0,804

10496

138

956

34

0,75

Total

No

50,5

57,2

0,865

10703

147

951

36

1,1

Total

No

49,5

55,9

0,978

11471

152

968

38

1,1

Total

No

48,7

54,9

1,057

11926

156

965

[Pa] [RPM]

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 6 POLE MOTORS - THGT F200 - F300
qv = Air volume in m3/h and m3/s.
psf = Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

psf
[Pa]

10 14
8 12 16

140

120

78

Nominal diameter (mm)


Number of blades

60

710
3

40

THGT/6-710-3/_-_ kW
Hz
63

25

25

22

125

19

17

18

250

11

10

500

1000

2000

4000

13

14

14

8000

20

22

23

Table of correction factors for the calculation of the


sound power level spectrum.

20

2224
81

82

B
A

80
THGT F200 - F300
Number of poles

18
20

100

283032
81

82

80

81

78

81

80

79

81dB(A) [LwA]

80

78

81

0
0

2000

4000

0.5

6000
1.5

8000
2

10000
2.5

12000
3

3.5

14000

16000

4.5

18000 qv [m3/h]
5

qv [m3/s]

P [W ]
800

32
30

700

28
600

24
22

500

20
18
16

400

14

300

10

12

200
0

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

Cylindrical cased axial ow fans THGT

2000

4000

6000

8000

10000

VSD* SR* d[%]*

12000

14000

16000

N*

[kW]

[m3/h]

35,6

45,0

0,325

5624

74

986

38,6

47,8

0,354

6974

71

984

No

42,1

51,0

0,390

7998

74

981

Total

No

44,0

52,7

0,427

8936

75

978

Total

No

44,9

53,3

0,470

9824

77

973

Total

No

46,6

54,8

0,512

10550

81

970

0,55

Total

No

48,3

56,2

0,555

10968

88

965

22

0,55

Total

No

49,4

57,1

0,597

12345

86

960

24

0,55

Total

No

50,8

58,3

0,657

12763

94

957

28

0,75

Total

No

53,9

61,3

0,680

14005

94

962

30

0,75

Total

No

55,4

62,5

0,742

14678

101

957

32

0,75

Total

No

55,0

61,9

0,800

15158

104

951

PM* MC*

EC*

0,55

Total

No

10

0,55

Total

No

12

0,55

Total

14

0,55

16

0,55

18

0,55

20

18000 qv [m3/h]

[Pa] [RPM]

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 6 POLE MOTORS - THGT F400
qv = Air volume in m3/h and m3/s.
psf = Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf
[Pa]

141618

180

160

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

120

100
THGT F400
Number of poles

Nominal diameter (mm)


Number of blades

80

710
5

60

THGT/6-710-5/_-_ kW

40
Hz

63

33

32

33

125

26

25

15

250

500

1000

2000

10

10

10

4000

17

16

16

8000

25

25

25

Table of correction factors for the calculation of the


sound power level spectrum.

28

140

20

22 24 26
20
82

84

B
A

30

82

82

83

80

81

81

0
2000

4000
1

6000
1.5

8000
2

32

82dB(A) [LwA]

81

80

10000
2.5

12000
3

82

14000

16000

4.5

3.5

18000
5

20000 qv [m3/h]
5.5

qv [m3/s]

P [W ]

1200

32
1000

30
28

800

26
22 24

600

20
18

400
2000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

www.solerpalau.com

14
4000

6000

8000

10000

16
12000

VSD* SR* d[%]*

14000

16000

18000

N*

[kW]

[m3/h]

38,2

46,3

0,532

6777

108

966

42,1

49,8

0,598

8188

111

961

No

43,8

51,3

0,656

8914

116

955

Total

No

45,3

52,5

0,727

9628

123

947

Total

No

45,8

52,7

0,804

10407

127

939

Total

No

52,5

59,4

0,798

11926

126

956

0,75

Total

No

52,0

58,7

0,882

12241

134

948

28

1,1

Total

No

52,1

58,3

1,033

13238

146

965

30

1,1

Total

No

51,4

57,4

1,117

13137

157

961

32

1,1

Total

No

50,0

55,7

1,243

14388

155

957

PM* MC*

EC*

14

0,55

Total

No

16

0,55

Total

No

18

0,55

Total

20

0,55

22

0,55

24

0,75

26

[Pa] [RPM]

Cylindrical cased axial ow fans THGT

20000 qv [m3/h]

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 6 POLE MOTORS - THGT F200 - F300
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf
[Pa]

10 14
8 12 16

180

160

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

140

120

84
100

THGT F200 - F300


Number of poles

Nominal diameter (mm)


Number of blades

80

710
6

60

THGT/6-710-6/_-_ kW

40
Hz

63

33

32

33

125

26

25

15

250

500

1000

2000

10

10

10

4000

17

16

16

8000

25

25

25

26 28 30
22 24

18 20

20

85

B
A

83

82

83

82
0
2000

4000
1

6000
1.5

82

10000
2.5

83

81

82

8000

32

83dB(A) [LwA]

81

81

81

12000
3

3.5

14000

16000

4.5

82

18000

20000 qv [m3/h]

5.5

qv [m3/s]

P [W ]
1200

32

Table of correction factors for the calculation of the


sound power level spectrum.

30
1000

28
26

800

24
22

600

400

200
2000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

Cylindrical cased axial ow fans THGT

4000

6000

8000

10 12

10000

14

16

12000

VSD* SR* d[%]*

18 20

14000

16000

18000

N*

[kW]

[m3/h]

37,5

46,0

0,448

5534

109

976

41,1

49,3

0,500

6537

113

971

No

43,8

51,8

0,549

7651

113

967

Total

No

44,9

52,6

0,609

8489

116

962

Total

No

47,9

55,3

0,666

9471

121

955

Total

No

48,7

55,9

0,734

10357

124

949

0,75

Total

No

57,8

65,0

0,724

11560

130

957

22

0,75

Total

No

58,5

65,4

0,803

12335

137

951

24

0,75

Total

No

56,8

63,5

0,876

13108

136

945

26

1,1

Total

No

57,5

63,8

1,007

14492

143

964

28

1,1

Total

No

56,2

62,3

1,100

15539

143

960

30

1,1

Total

No

55,9

61,7

1,197

16292

148

956

32

1,1

Total

No

54,6

60,2

1,297

16676

153

951

PM* MC*

EC*

0,55

Total

No

10

0,55

Total

No

12

0,55

Total

14

0,55

16

0,55

18

0,55

20

20000 qv [m3/h]

[Pa] [RPM]

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 6 POLE MOTORS - THGT F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf
[Pa]

180

1618

160

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

28

Nominal diameter (mm)


Number of blades

80

710
7

60

THGT/6-710-_/_-_ kW

40
Hz

63

33

33

28

125

18

15

18

250

10

500

1000

2000

10

4000

13

16

13

8000

19

25

21

Table of correction factors for the calculation of the


sound power level spectrum.

22
20

120

100
Number of poles

26
24

140

THGT F400

20

30 32

84

84

B
A

0
4000

82

81

8000
2

84

81

82

6000
1.5

83

82

80

10000
2.5

12000
3

83 dB(A) [LwA]

83

14000

16000

4.5

3.5

18000

20000 qv [m3/h]

5.5

qv [m3/s]

P [W ]
1400

1200

32
30

1000

28
26

800

22
600

16
400
4000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

www.solerpalau.com

24

20

6000

8000

10000

18

12000

VSD* SR* d[%]*

14000

16000

18000

20000 qv [m3/h]

N*

[kW]

[m3/h]

37,9

45,3

0,665

7699

118

953

40,2

47,4

0,741

8608

124

945

No

42,1

49,0

0,813

9460

130

939

Total

No

42,5

49,1

0,909

9986

139

926

Total

No

49,1

55,5

0,967

11027

155

944

Total

No

49,8

55,9

1,088

12102

161

961

1,1

Total

No

48,7

54,6

1,191

12950

160

957

30

1,1

Total

No

48,6

54,2

1,312

13417

171

953

32

1,1

Total

No

47,7

53,0

1,439

13853

178

947

PM* MC*

EC*

16

0,55

Total

No

18

0,55

Total

No

20

0,55

Total

22

0,55

24

0,75

26

1,1

28

[Pa] [RPM]

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 6 POLE MOTORS - THGT F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

psf
[Pa]

18

140

120

100

80

32

30
28
20 2224 26

84

84

86

THGT F400
Number of poles

Nominal diameter (mm)


Number of blades

40

63

85 dB(A) [LwA]

THGT/6-800-3/_-_ kW
Hz

83

82

60

800

25

25

22

125

19

17

18

250

11

10

500

1000

2000

4000

13

14

14

8000

20

22

23

Table of correction factors for the calculation of the


sound power level spectrum.

20

0
4000

6000

82

8000

10000

12000

14000

83

16000

18000

85

20000

22000

24000 qv [m3/h]

qv [m3/s]

P [W ]
1400

32
1200

30
28

1000

26
800

24
22

600

18
400
4000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

Cylindrical cased axial ow fans THGT

6000

8000

10000

12000

14000

VSD* SR* d[%]*

16000

20

18000

20000

22000

24000 qv [m3/h]

N*

[kW]

[m3/h]

[Pa] [RPM]

51,1

58,6

0,647

10976

108

966

51,5

58,7

0,739

12113

113

960

No

50,9

57,7

0,829

12931

118

953

Total

No

50,0

56,5

0,935

13342

126

947

Total

No

50,8

57,0

1,064

13966

140

963

Total

No

49,0

54,8

1,202

14163

150

959

1,5

Total

No

49,9

55,5

1,307

15018

157

973

1,5

Total

No

47,7

53,0

1,473

15147

167

969

PM* MC*

EC*

18

0,75

Total

No

20

0,75

Total

No

22

0,75

Total

24

0,75

26

1,1

28

1,1

30
32

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 6 POLE MOTORS - THGT F200 - F300
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

psf
[Pa]

140

8
120

THGT F200 - F300


6

Nominal diameter (mm)


Number of blades

60

800
3

40

THGT/6-800-3/_-_ kW
Hz

63

25

25

22

125

19

17

18

250

11

10

500

1000

2000

4000

13

14

14

8000

20

22

23

Table of correction factors for the calculation of the


sound power level spectrum.

16

100

80
Number of poles

12
10 14

20

B
A

84

85

2830
84

84

85

83

6000
1

86

83

82

10000
2

32

82

85
0
2000

18202224

82

14000

85 dB(A) [LwA]

18000

85

83

22000

26000 qv [m3/h]

qv [m3/s]

P [W ]

32
30

1300

1100

28

900

24
22

700

500

8
300
2000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

www.solerpalau.com

6000

10000

10

12

20
16 18
14

14000

VSD* SR* d[%]*

18000

22000

26000 qv [m3/h]

N*

[kW]

[m3/h]

38,2

46,9

0,425

8812

66

972

41,9

50,3

0,473

10172

70

971

No

45,1

53,3

0,514

11625

72

966

Total

No

47,3

55,1

0,593

12503

81

959

Total

No

49,3

56,8

0,643

13659

84

953

Total

No

57,3

64,8

0,658

14821

92

964

0,75

Total

No

57,9

65,1

0,719

15560

96

958

22

0,75

Total

No

56,7

63,7

0,790

17074

94

954

24

1,1

Total

No

54,7

61,3

0,905

17899

100

968

28

1,1

Total

No

51,6

57,6

1,147

20280

105

958

30

1,1

Total

No

54,0

59,7

1,270

21623

114

955

32

1,5

Total

No

55,4

61,0

1,329

21698

122

971

PM* MC*

EC*

0,55

Total

No

10

0,55

Total

No

12

0,55

Total

14

0,55

16

0,55

18

0,75

20

[Pa] [RPM]

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 6 POLE MOTORS - THGT F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

psf

12 16
10 1418

[Pa]

210

32
28
26
24

180

20
150

THGT F400
Number of poles

Nominal diameter (mm)


Number of blades

86

90

86

86

800

87

84

85

86 dB(A) [LwA]

60
THGT/6-800-6/_-_ kW
Hz

88

120

22

63

33

33

28

125

18

15

18

250

10

500

1000

2000

10

4000

15

16

13

8000

23

25

21

Table of correction factors for the calculation of the


sound power level spectrum.

30

85

84

85

86

0
0

3000

6000

9000
2

12000
3

15000

18000

21000

24000

27000 qv [m3/h]
7

qv [m3/s]

P [W ]

2000

32
1600

28
26

1200

24
22
20

800

18
16
14
10 12

400
0

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

Cylindrical cased axial ow fans THGT

3000

6000

9000

12000

15000

VSD* SR* d[%]*

18000

21000

24000

N*

[kW]

[m3/h]

40,2

47,9

0,615

6755

132

968

43,6

50,9

0,690

8915

121

965

No

45,8

52,8

0,771

9809

129

959

Total

No

47,4

54,2

0,848

11281

128

953

Total

No

48,3

54,7

0,978

12175

140

943

Total

No

51,0

56,9

1,171

13746

156

960

1,1

Total

No

52,2

57,7

1,362

15136

169

951

24

1,5

Total

No

54,7

59,9

1,488

15903

184

967

26

1,5

Total

No

53,9

58,8

1,664

16646

194

962

28

2,2

Total

No

53,2

57,8

1,904

17963

203

969

30

2,2

Total

No

52,0

56,5

1,946

19621

185

970

32

2,2

Total

No

53,0

57,1

2,276

18873

230

963

PM* MC*

EC*

10

0,75

Total

No

12

0,75

Total

No

14

0,75

Total

16

0,75

18

0,75

20

1,1

22

27000 qv [m3/h]

[Pa] [RPM]

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 6 POLE MOTORS - THGT F200 - F300
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

psf
[Pa]

210

12
10 1416
8

180

18 20
82
120

THGT F200 - F300


Number of poles

Nominal diameter (mm)


Number of blades

90

800
6

60

THGT/6-800-6/_-_ kW
Hz

63

33

33

28

125

18

15

18

250

10

500

1000

2000

10

4000

13

16

13

8000

19

25

21

Table of correction factors for the calculation of the


sound power level spectrum.

150

30

88

B
A

26 28 32
30
22 24
86
87
86

86

86

84

86
0
3000

6000

9000
2

85

85

12000
3

15000

84

18000

21000

86 dB(A) [LwA]

85

86

24000

27000

30000 qv [m3/h]
8

qv [m3/s]

P [W ]

2000

32
30

1600

28
26
24

1200

20
18

800

12 14
8 10
400
3000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

www.solerpalau.com

22

6000

9000

12000

15000

16

18000

VSD* SR* d[%]*

21000

24000

27000

N*

[kW]

[m3/h]

42,8

50,4

0,641

8478

116

955

44,2

51,6

0,681

9743

111

951

No

48,0

55,0

0,781

11414

118

939

Total

No

55,4

62,4

0,775

12560

123

954

Total

No

57,0

63,5

0,925

14084

134

942

Total

No

57,7

63,9

1,043

15966

135

963

1,1

Total

No

57,9

63,8

1,189

17293

143

956

22

1,5

Total

No

61,8

67,4

1,316

19389

151

970

24

1,5

Total

No

61,3

66,6

1,482

19830

165

972

26

1,5

Total

No

59,2

64,1

1,684

20923

171

960

28

2,2

Total

No

59,6

64,3

1,832

22093

178

971

30

2,2

Total

No

59,6

64,1

1,923

23966

172

968

32

2,2

Total

No

59,0

63,3

2,128

24020

188

962

PM* MC*

EC*

0,55

Total

No

10

0,55

Total

No

12

0,55

Total

14

0,75

16

0,75

18

1,1

20

30000 qv [m3/h]

[Pa] [RPM]

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 6 POLE MOTORS - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf
[Pa]

141618

240

32
30

210

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

Number of blades

20

90

88

87

88

800

88

86

86

87 dB(A) [LwA]

90

60

THGT/6-800-9/_-_ kW

63

150

Nominal diameter (mm)

Hz

24
22

120

THGT F200 - F300 - F400


Number of poles

180

28
26

37

31

29

125

22

15

16

250

11

10

500

1000

2000

4000

14

15

11

8000

22

23

19

Table of correction factors for the calculation of the


sound power level spectrum.

30

0
3000

87

6000

9000
2

85

12000

15000

86

18000

21000

87

24000

27000 qv [m3/h]
7

qv [m3/s]

P [W ]

2500

32
2000

30
28
26

1500

24
22
20

1000

18
14

500
3000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

Cylindrical cased axial ow fans THGT

6000

9000

12000

16

15000

VSD* SR* d[%]*

18000

21000

24000

27000 qv [m3/h]

N*

[kW]

[m3/h]

38,5

45,0

0,934

8841

147

947

40,9

47,1

1,035

10721

142

937

No

44,6

50,3

1,257

12373

163

954

Total

No

46,0

51,5

1,372

13300

171

948

Total

No

50,1

55,2

1,583

14804

193

965

Total

No

52,5

57,2

1,813

16663

204

973

2,2

Total

No

52,4

56,8

2,041

17982

213

968

28

2,2

Total

No

52,9

57,0

2,248

19110

223

964

30

Total

No

54,2

58,0

2,499

19637

248

979

32

Total

No

53,6

57,2

2,741

21147

249

976

PM* MC*

EC*

14

0,75

Total

No

16

0,75

Total

No

18

1,1

Total

20

1,1

22

1,5

24

2,2

26

[Pa] [RPM]

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 6 POLE MOTORS - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

THGT F200 - F300 - F400


Number of poles

Number of blades

160

30

140

24
22
20

120

100

80

86

32

28
26

89

87

88

90

85

87

900

60

THGT/6-900-3/_-_ kW

63

14
8 1012 1618

Nominal diameter (mm)

Hz

psf
[Pa]

89

25

22

125

19

17

18

250

11

10

500

1000

2000

4000

13

14

14

8000

20

22

23

Table of correction factors for the calculation of the


sound power level spectrum.

89 dB(A) [LwA]

40

25

86

20

89

85

85

87

24000

28000

32000 qv [m3/h]

qv [m3/s]

89

0
0

4000

8000

12000

16000

20000
5

P [W ]

32
2000

30
28
26

1600

24
22

1200

18
800

16
8

400
0

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

www.solerpalau.com

20

4000

8000

12000

10

16000

VSD* SR* d[%]*

12

14

20000

24000

28000

32000 qv [m3/h]

N*

[kW]

[m3/h]

40,0

48,0

0,538

9118

85

992

44,8

52,5

0,617

11309

88

990

No

48,5

55,7

0,727

12883

98

988

Total

No

51,3

58,2

0,826

14011

109

986

Total

No

52,6

59,2

0,909

15896

108

985

Total

No

53,7

59,8

1,089

17299

122

980

1,5

Total

No

54,2

60,0

1,205

17275

136

976

22

1,5

Total

No

53,6

59,1

1,374

18995

140

972

24

1,5

Total

No

52,3

57,5

1,535

20199

143

969

26

1,5

Total

No

52,2

57,1

1,665

21042

149

964

28

2,2

Total

No

51,6

56,1

1,933

22445

160

971

30

2,2

Total

No

50,4

54,7

2,136

23206

167

968

32

2,2

Total

No

49,8

53,8

2,333

24262

173

964

PM* MC*

EC*

1,5

Total

No

10

1,5

Total

No

12

1,5

Total

14

1,5

16

1,5

18

1,5

20

[Pa] [RPM]

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 6 POLE MOTORS - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

THGT F200 - F300 - F400


Number of poles

psf

12 16
810 14 18

[Pa]

240

200

32

20 22
160

120

92

89

89

91

Nominal diameter (mm)


Number of blades

900

90

80

THGT/6-900-6/_-_ kW
Hz

30
24 28

63

33

33

28

125

18

15

18

250

10

500

1000

2000

10

4000

15

16

13

8000

23

25

21

Table of correction factors for the calculation of the


sound power level spectrum.

40

89

90

87

88

88

87

90 dB(A) [LwA]

88

90

0
0

5000

10000
2

15000

20000

25000

30000
8

35000
9

40000 qv [m3/h]

10

11

qv [m3/s]

P [W ]
4000

32

3500

30

3000

28
2500

24

2000

22
1500

16

1000

12
8 10

500
0

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

Cylindrical cased axial ow fans THGT

5000

10000

15000

18

20

14

20000

VSD* SR* d[%]*

25000

30000

35000

40000 qv [m3/h]

N*

[kW]

[m3/h]

40,1

46,8

0,867

7680

163

985

42,0

48,5

0,951

11513

125

983

No

45,6

51,7

1,083

15398

114

979

Total

No

49,4

55,0

1,296

16002

144

976

Total

No

51,7

56,8

1,553

17712

163

980

Total

No

53,1

58,0

1,666

20075

158

976

2,2

Total

No

51,5

56,2

1,845

21549

158

974

22

Total

No

53,8

57,9

2,260

23462

185

983

24

Total

No

54,6

58,3

2,570

24629

205

979

28

Total

No

53,1

56,3

3,180

25980

234

973

30

Total

No

52,6

55,5

3,489

29274

225

970

32

Total

No

50,0

52,6

3,944

31583

224

981

PM* MC*

EC*

1,5

Total

No

10

1,5

Total

No

12

1,5

Total

14

1,5

16

2,2

18

2,2

20

[Pa] [RPM]

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 6 POLE MOTOR - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

psf
[Pa]

14
12 1618

280

240

22
160

THGT F200 - F300 - F400


Number of poles

Nominal diameter (mm)


Number of blades

120

900
9

80

THGT/6-900-9/_-_ kW
Hz

63

37

31

29

125

22

15

16

250

11

10

500

1000

2000

4000

14

15

11

8000

22

23

19

Table of correction factors for the calculation of the


sound power level spectrum.

40

20

200

B
A

0
5000

93

30 32

91

90

91

15000

91

89

89

90

10000
2

28
24 26

89

20000
5

89

25000
6

91 dB(A) [LwA]

91

30000

35000
9

40000 qv [m3/h]

10

11

qv [m3/s]

P [W ]
4500

32

4000
3500

30
28

3000

26

2500

24
22

2000

20
18

1500

12 14

1000
5000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

www.solerpalau.com

16

10000

15000

20000

25000

PM* MC*

EC*

VSD* SR* d[%]*

12

1,5

Total

No

14

1,5

Total

No

16

1,5

Total

18

2,2

20

2,2

22

2,2

24

30000

35000

40000 qv [m3/h]

N*

[kW]

[m3/h]

[Pa] [RPM]

39,9

45,1

1,495

10156

212

970

41,4

46,6

1,533

16449

137

969

No

44,3

49,1

1,770

17784

157

962

Total

No

44,7

49,0

2,068

19061

175

970

Total

No

47,2

51,3

2,245

21926

173

964

Total

No

50,4

54,2

2,558

23852

193

961

Total

No

51,5

54,9

2,966

26354

208

977

26

Total

No

52,5

55,5

3,397

27426

232

972

28

Total

No

49,1

51,6

4,070

29781

240

981

30

5,5

Total

No

51,4

53,8

4,178

31974

242

983

32

5,5

Total

No

50,2

52,4

4,561

33940

243

981

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 6 POLE MOTORS - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

psf
[Pa]

180

32

1416
22 24 26
20

160

18

140

91

120

100

90

Nominal diameter (mm)


Number of blades

1000
3

60

THGT/6-1000-3/_-_ kW
Hz
63

89

80

40

25

25

22

125

19

17

18

250

11

10

500

1000

2000

4000

13

14

14

8000

20

22

23

Table of correction factors for the calculation of the


sound power level spectrum.

93

91

THGT F200 - F300 - F400


Number of poles

30

28

88

92 dB(A) [LwA]

90

A
88

20

0
8000

12000
3

16000
4

20000
5

88

24000

28000

32000

90

36000

92

40000

10

44000 qv [m3/h]

11

12

qv [m3/s]

P [W ]

32

3500

30
3000

28
26

2500

24
2000

22
20
18

1500

16

14
1000
8000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

Cylindrical cased axial ow fans THGT

12000

16000

20000

24000

28000

VSD* SR* d[%]*

32000

36000

40000

44000 qv [m3/h]

N*

[kW]

[m3/h]

[Pa] [RPM]

57,8

63,5

1,273

19885

133

979

57,5

62,7

1,497

21530

144

973

No

59,3

64,2

1,686

22951

157

968

Total

No

59,9

64,5

1,886

24690

165

971

Total

No

59,5

63,8

2,088

26108

172

967

Total

No

57,6

61,6

2,325

30726

157

961

Total

No

54,7

58,2

2,827

29176

191

981

28

Total

No

56,0

59,3

3,077

30308

205

978

30

Total

No

55,3

58,3

3,365

31836

211

976

32

5,5

Total

No

54,8

57,5

3,696

33067

221

982

PM* MC*

EC*

14

1,5

Total

No

16

1,5

Total

No

18

1,5

Total

20

2,2

22

2,2

24

2,2

26

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 6 POLE MOTORS - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf

240

10
18

180

150

91

26

22
20

94

24

92

94

92

B
94

92

90

91

93 dB(A) [LwA]

Nominal diameter (mm)


Number of blades

1000

90

60

THGT/6-1000-6/_-_ kW
Hz

30
28

120

THGT F200 - F300 - F400


Number of poles

1214

16
210

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

32

[Pa]

63

33

33

28

125

18

15

18

250

10

500

1000

2000

10

4000

15

16

13

8000

23

25

21

Table of correction factors for the calculation of the


sound power level spectrum.

A
94

30

0
8000

91

16000
3

24000
6

90

32000
8

91

40000
10

11

93

48000
12

13

56000 qv [m3/h]
14

15

qv [m3/s]

P [W ]
6000

32
5000

30
28

4000

26
24
3000

22
20
18

2000

8 10

1000
8000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

www.solerpalau.com

16000

14

12

24000

16

32000

VSD* SR* d[%]*

40000

48000

56000 qv [m3/h]

N*

[kW]

[m3/h]

[Pa] [RPM]

51,1

56,7

1,311

13795

175

976

50,0

55,2

1,518

16457

166

972

No

54,0

58,8

1,738

18990

178

966

Total

No

57,7

62,1

2,058

22302

192

969

Total

No

60,0

64,0

2,308

24669

202

965

Total

No

59,4

62,8

2,889

27332

226

980

Total

No

59,2

62,3

3,300

29697

237

979

22

Total

No

60,1

62,9

3,652

30390

260

982

24

Total

No

58,4

60,9

4,017

33049

256

980

26

5,5

Total

No

62,0

64,3

4,402

35136

280

980

28

5,5

Total

No

61,1

63,1

4,936

36463

298

977

30

5,5

Total

No

61,3

63,0

5,328

38513

305

975

32

5,5

Total

No

60,3

61,7

6,093

40173

329

971

PM* MC*

EC*

1,5

Total

No

10

1,5

Total

No

12

1,5

Total

14

2,2

16

2,2

18

20

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 6 POLE MOTORS - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

THGT F200 - F300 - F400


Number of poles

Number of blades

121416

320

10
280

18 20
24

22
240

200

160
6

Nominal diameter (mm)

92

96

2628

92

30

32

93

95

B
94

95

1000

92

92

94 dB(A) [LwA]

120

THGT/6-1000-9/_-_ kW
Hz

psf
[Pa]

80

63

37

31

29

125

22

15

16

250

11

10

500

1000

2000

4000

14

15

11

8000

22

23

19

Table of correction factors for the calculation of the


sound power level spectrum.

40

95
0
8000

93

16000
3

24000
6

91

32000

40000
10

94

92

11

48000
12

13

56000 qv [m3/h]
14

15

qv [m3/s]

P [W ]
7000

32
30

6000

28

5000

26
4000

24
20

3000

22

18
14

2000

10

8
1000
8000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

Cylindrical cased axial ow fans THGT

16000

16

12

24000

32000

VSD* SR* d[%]*

40000

48000

56000 qv [m3/h]

N*

[kW]

[m3/h]

[Pa] [RPM]

45,3

50,1

1,767

12137

240

973

47,2

51,7

1,984

14822

227

969

No

52

56,2

2,19

18966

215

963

Total

No

52,2

55,8

2,704

23325

217

982

Total

No

56,1

59,4

2,993

25633

234

978

Total

No

57,3

60,2

3,487

27989

257

974

Total

No

58,4

60,9

4,000

29917

281

982

22

5,5

Total

No

61,7

64,0

4,285

32217

295

981

24

5,5

Total

No

61,8

63,7

4,969

35361

313

978

26

5,5

Total

No

62,1

63,7

5,535

37749

328

975

28

5,5

Total

No

60,8

62,2

6,024

39945

330

971

30

7,5

Total

No

59,3

60,3

6,937

42978

345

984

32

7,5

Total

No

61,4

62,2

7,634

45015

375

978

PM* MC*

EC*

2,2

Total

No

10

2,2

Total

No

12

2,2

Total

14

16

18

20

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 6 POLE MOTORS - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf
[Pa]

220

22
20
18
16

1012 14
8

28
2426

30 32

200

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

180

98

160

140
THGT F200 - F300 - F400
Number of poles

Number of blades

100

1250
3

100

THGT/6-1250-3/_-_ kW
Hz

96

97

100

120

Nominal diameter (mm)

97

80

63

25

25

22

125

19

17

18

250

11

10

500

1000

2000

4000

13

14

14

8000

20

22

23

Table of correction factors for the calculation of the


sound power level spectrum.

95

94

96

99 dB(A) [LwA]

60

100
40
10000

94

30000
4

94

96

50000
10

12

14

70000
16

18

20

24

qv [m3/s]

32
30

8000

28

7000

26
24
22

4000

18

20

16

3000

14

2000

1000
10000

www.solerpalau.com

22

9000

5000

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

90000 qv [m3/h]

P [W ]

6000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

99

10

30000

12

50000
VSD* SR* d[%]*

70000

90000 qv [m3/h]

N*

[kW]

[m3/h]

[Pa] [RPM]

57,6

62,3

1,814

27979

135

972

61,1

65,3

2,18

30147

159

981

No

63

66,9

2,454

37682

147

979

Total

No

62,8

66,2

2,928

39380

168

974

Total

No

61,0

63,8

3,649

43780

183

983

Total

No

62,1

64,4

4,284

47791

201

979

5,5

Total

No

64,9

67,0

4,604

50506

214

978

22

5,5

Total

No

63,7

65,6

5,126

51979

227

975

24

5,5

Total

No

63,3

64,8

5,800

56271

236

971

26

7,5

Total

No

61,6

62,7

6,729

58759

256

984

28

7,5

Total

No

63,4

64,2

7,392

62995

270

982

30

7,5

Total

No

63,5

64,1

8,179

65820

287

979

32

11

Total

No

63,7

64,0

9,062

69622

303

988

PM* MC*

EC*

2,2

Total

No

10

Total

No

12

Total

14

16

18

20

Cylindrical cased axial ow fans THGT

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 6 POLE MOTORS - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

psf
[Pa]

10 12 14
8
18 20
16

99
250

200

Nominal diameter (mm)


Number of blades

26

28

30

100

99

98

101 dB(A) [LwA]

1250

101

150
THGT/6-1250-6/_-_ kW
Hz

22 24

300

THGT F200 - F300 - F400


Number of poles

32

350

63

33

33

28

125

18

15

18

250

10

500

1000

2000

10

4000

15

16

13

8000

23

25

21

Table of correction factors for the calculation of the


sound power level spectrum.

100

98

96

98

100

A
101

50
10000

30000
4

97

96

50000
10

12

14

98

70000
16

18

100

90000

20

22

24

qv [m3/h]

26

qv [m3/s]

P [W ]

32

14000

30
12000

28
26

10000

24
22

8000

20
6000

18
16
14

4000

8
2000
10000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

Cylindrical cased axial ow fans THGT

30000

12

10
50000

VSD* SR* d[%]*

70000

90000

N*

[kW]

[m3/h]

[Pa] [RPM]

55,5

58,5

3,423

31205

219

985

58,7

61,4

3,824

34362

235

981

No

64,5

66,7

4,489

39942

261

980

Total

No

66,2

68,0

5,310

45488

278

975

Total

No

66,2

67,6

6,016

49612

289

970

Total

No

69,1

70,1

6,939

53578

322

983

7,5

Total

No

68,9

69,5

7,952

58698

336

980

22

11

Total

No

69,8

70,1

9,065

62532

365

986

24

11

Total

No

69,0

69,1 10,024

65821

380

985

26

11

Total

No

68,9

68,9 11,670

70018

415

980

28

15

Total

No

70,1

70,0 12,725

74098

437

985

30

15

Total

No

69,6

69,4 14,066

77246

461

983

32

15

Total

No

68,9

68,6 15,490

80168

486

982

PM* MC*

EC*

Total

No

10

Total

No

12

5,5

Total

14

5,5

16

5,5

18

7,5

20

qv [m3/h]

www.solerpalau.com

CYLINDRICAL CASED AXIAL FLOW FANS


THGT Series
PERFORMANCE CURVES - 6 POLE MOTORS - THGT F200 - F300 - F400
qv: Air volume in m3/h and m3/s.
psf: Static pressure in Pa.
Dry air at 20C and 760 mmHg.
Performance data in accordance with ISO 5801 and
AMCA 210-99 Standards.

psf
[Pa]

10 12 14
8

450

400

THE SOUND LEVEL VALUES IN THE


PERFORMANCE CURVES CORRESPOND TO
SOUND POWER LEVELS LwA. TO CONVERT THIS
DATA INTO SOUND PRESSURE LEVEL VALUES
LpA, SUBTRACT REDUCTION DUE TO DISTANCE.

350

THGT F200 - F300 - F400

250

Number of poles

Number of blades

1250

24 26
20 22

102

28 30

32

100

100

102 dB(A) [LwA]

B
102

200

150

THGT/6-1250-9/_-_ kW

63

100

18

Nominal diameter (mm)

Hz

300

16

37

31

29

125

22

15

16

250

11

10

500

1000

2000

4000

14

15

11

8000

22

23

19

Table of correction factors for the calculation of the


sound power level spectrum.

99

98

100

101

100

102
50
10000

30000
4

97

99
50000

10

12

14

99

70000
16

18

101

90000

20

22

24

110000 qv [m3/h]

26

28

30

qv [m3/s]

P [W ]

32
30

18000

28
14000

26
24
22

10000

20
18
6000

8 10
2000
10000

MC
EC
VSD
SR
d[%]
N
[kW]
[m3/h]
[Pa]
[RPM]

Measurement category
Efficiency category
Speed control: supplied with the fan
Specific ratio
Total efficiency
Efficiency grade
Absorbed power
Air volume
Total pressure
Speed

www.solerpalau.com

30000

12

14

50000

16

70000

VSD* SR* d[%]*

90000

110000 qv [m3/h]

N*

[kW]

[m3/h]

[Pa] [RPM]

53,6

55,9

4,345

29083

288

980

57,5

59,5

4,899

36937

274

978

No

59,7

61,3

5,618

40821

296

973

Total

No

63,7

64,9

6,524

45225

331

984

Total

No

64,4

65,2

7,413

49548

347

980

Total

No

66,7

67,1

8,699

55515

375

985

11

Total

No

67,9

68,0 10,246

62272

402

981

22

11

Total

No

68,1

68,1 11,769

66864

432

978

24

15

Total

No

71,1

71,0 12,993

71462

467

987

26

15

Total

No

70,1

69,9 14,806

74687

502

984

28

18,5

Total

No

69,5

69,2 16,548

77638

535

988

30

18,5

Total

No

69,2

68,8 18,477

81225

571

986

32

22

Total

No

66,8

66,3 20,405

86388

576

987

PM* MC*

EC*

5,5

Total

No

10

5,5

Total

No

12

5,5

Total

14

7,5

16

7,5

18

11

20