ABB LV Power Protection Solutions PCS100 AVC, 160 kVA to 20 MVA Active Voltage Conditioner

Service and support PCS100 team provide global service and support of installation and commisioning of PCS100 products
Comprehensive global services portfolio ABB services span the entire product ownership life cycle: - Pre-purchase engineering - Installation and commissioning - Technical support - Training - Preventive and corrective maintenance and maintenance spare parts kits - Retrofit and refurbishment - Globally available, supported by regional service hubs and operating in more than 100 countries - Spare part availability and stocking - On-site repairs - 24 x 365 local support line Custom tailored service contracts - ABB services can be packaged into a custom service contract - Tailored to the specific needs of each customer - Contracts can be made at any stage of ABB product ownership - Service contracts provide customers with improved cost controls, increased operational efficiency, lower capital expenditures, and extend ABB product life time Life cycle management ABBs life cycle management model maximizes the value of the equipment and maintenance investment by maintaining high availability, eliminating unplanned repair costs and extending the lifetime of the drive. Life cycle management includes: - Spare parts and expertise throughout the life cycle - Efficient product support and maintenance for improved reliability - Functionality upgrades to the initial product Engineering and technical support ABBs engineering team provides the necessary electrical, protective and monitoring equipment, delivering a high level of energy continuity and superior power quality in a safe and cost effective system. The PCS100 is available in several capacities, depending on the scope of application. - Pre-purchase engineering to help select and integrate ABB PCS100 products - Customer assistance in sizing and modeling of systems - Other life cycle engineering and technical support is available by phone, email, or on-site visits, or as agreed in an ABB services contract - Redundant inverter design increases reliability and availability and is part of a proven family of global ABB products - Scalable building block design Training - Product training includes installation, commissioning, and maintenance - Training either at ABB Universities or at a customer site - Training can be included in an ABB services contract

2 Product brochure | PCS100 Active Voltage Conditioner

PCS100 AVC, 160 kVA to 20 MVA Protects sensitive industrial and commercial loads from voltage disturbances
Product overview The ABB PCS100 AVC is an inverter based system that protects sensitive industrial and commercial loads from voltage disturbances. Providing fast, accurate voltage sag and surge correction as well as continuous voltage regulation and load voltage compensation, the PCS100 AVC has been optimally designed to give required equipment immunity from the level of voltage sags expected on the AC supply network. Available in load capacities of 160 kVA - 20 MVA the PCS100 AVC has an operating efficiency exceeding 98%. User benefits Reliable Low maintenance Small footprint High efficiency Features - Simple user controls - Rugged overload capability - Short circuit protected - Extensive diagnostics - Fault log and voltage event data logging - Ethernet connectivity - Modular construction Performance 30% AVC Three-phase voltage sags: - 70% remaining 100% correction - 60% remaining 90% correction Single-phase voltage sags: - 55% remaining 100% correction 40% AVC Three-phase voltage sags: - 60% remaining 100% correction - 50% remaining 90% correction PCS100 Active Voltage Conditioner ( AVC ) Single-phase voltage sags: - 45% remaining 100% correction Generic performance - Partial correction, three-phase sags down to 30% remaining voltage - Partial correction, single-phase sags down to 0% remaining voltage - Continuous ONLINE regulation - Correction for voltage vector phase angle errors created by faults in the supply - Voltage unbalance correction - Flicker mitigation Single line diagram Typical configuration

Utility network Input voltage waveform Input circuit breaker 3ph utility supply Customer supplied Auxiliary circuit breaker Inverter / Bypass
Auto transformer ( only for 208/220V supplies )

3ph compensating voltage Injection transformer

Output voltage waveform

Non essential support loads - Pumps and fans - Lighting - Air conditioning - Heating

3ph load voltage

PCS100 AVC

Essential process loads - Measurement - Monitoring - Control - Variable speed drives tools - Vacuum pumps - Semiconductor tools

Rectifier

The PCS100 AVC protects UPS operation and gives extended battery life

UPS

Critical control loads - Computers - PLCs - DCS - SCADA

PCS100 Active Voltage Conditioner | Product brochure 3

Technical specifications
Model Range Rating Utility Input Voltage Voltage tolerance Frequency Frequency tolerance Power system type Over voltage category Fault capacity Output Voltage Voltage regulation Equivalent series impendance Displacement power factor Crest factor Performance Efficiency Overload capability Sag correction response Sag depth for full correction Transformer Transformer type Insulation Finish Vector group Bypass Capacity of model rating Overload capacity 100% (kVA) 125% for 10 minutes 150% for 1 minute 500% for 1 second 2000% for 200 ms Transfer time inverter Transfer time bypass Equiv series impedance Serial comms Access protocol Ethernet connectivity Modbus-TCP to bypass < 0.5 ms to inverter < 250 ms bypass < 2.5% typical Certifications Safety, EMC Semi F47 Quality Controls 210 mm colour LCD display Touch panel All adjustments and monitoring in English alphanumerics Full parameter control C-Tick,CE pending By test ISO 9001 Dry UL class N, 200C Dipped for moisture proofing Diii > 98% (typically 99%) 150% for 30 sec, once per 500s Initial < 250 us, Complete < 1/2 cycle 30% standard, 40% option Control inputs Control outputs Service MTTR Diagnostics Remote monitoring Standards Quality Marking Safety EMC Performance ISO 9001 CE IEC 62103 - Electronic equipment for use in power installations CISPR 11 class A Semi F47 IEC 61000-4-34 Testing and measurement techniquesvoltage dips, short interruptions and voltage variations 30 min typical by module exchange Non volatile event & service log Optional secure connection to ABB To match input voltage note 2 +/- 1% typical to +/- 2% max < 4% (model specific) 0 lagging to 0.9 leading 2.0 at rated power 208-480 V +/- 10% 50-60 Hz +/- 5 Hz TN-S III 20 pu for 200 ms note 3 150 to 2400 kVA note 1 Environmental Min operating temp Max operating temp Cooling power electronics Cooling transformer Humidity Pollution degree rating Noise Enclosure IP rating Enclosures options Enclosure colour Altitude above sea level Interface User interface Communications 8.4" color touchpanel Modbus TCP Ethernet Remote web server Ethernet Start & Stop/reset digital inputs Runing, warning and fault relays 0C, 32F 40C, 104F (with derating to 50C, 122F ) Fan forced ventilation Fan assisted ventilation < 95%, non-condensing 2 < 75 dBA @ 2 m IP20 / NEMA 1 IP21 Dust protection (filters) RAL 7035 < 1000 m without derating
2UCD301081-P_i

Note 1: Higher power avaliable by request Voltage set point Adjustable in 0.1% steps Note 2: Output voltage can be adjusted by +/- 10% in 0.1% steps Note 3: Upstream protection must be installed as per product documentation * All specifications are subject to change without prior notice.