Anda di halaman 1dari 9

Product data sheet

6AV6647-0AF11-3AX0
SIMATIC HMI KTP1000 BASIC COLOR PN, BASIC PANEL, KEY AND TOUCH OPERATION, 10" TFT DISPLAY, 256 COLORS, PROFINET INTERFACE, CONFIGURATION FROM WINCC FLEXIBLE 2008 SP2 COMPACT/ WINCC BASIC V10.5/ STEP7 BASIC V10.5, CONTAINS OPEN SOURCE SW WHICH IS PROVIDED FREE OF CHARGE FOR DETAILS SEE CD

Display
Design of display Screen diagonal Display width Display height Number of colors TFT 10.4 in 211.2 mm 158.4 mm 256

Resolution (pixels)
Horizontal image resolution Vertical image resolution 640 480

Backlighting
MTBF backlighting (at 25 C) Dimmable backlight 50000 h No

Control elements Keyboard fonts


Number of function keys Keys with LED System keys Numeric/alphabetical input Numeric keyboard Yes ; Onscreen keyboard 8 No No

6AV6647-0AF11-3AX0 Page 1/ 9

07/11/2013

subject to modifications Copyright Siemens AG 2013

Alphanumeric keyboard

Yes ; Onscreen keyboard

Touch operation
Design as touch screen Yes

Installation type/mounting
Mounting in portrait format possible Mounting in landscape format possible No Yes

Supply voltage
Type of supply voltage Rated voltage/DC permissible range, lower limit (DC) permissible range, upper limit (DC) DC 24 V 19.2 V 28.8 V

Input current
Current consumption (rated value) Inrush current As 0.6 A 0.2 As

Power
Power consumption, typ. 15 W

Processor
Processor type X86 ARM No Yes ; RISC 32-bit

Memory
Flash RAM Usable memory for user data Yes Yes 2 Mbyte

Type of output
Acoustics Buzzer Speaker Yes No

Time of day Clock


Hardware clock (real-time clock) Software clock Battery-backed Synchronizable No Yes No Yes

Interfaces
Number of RS 485 interfaces Number of USB interfaces Number of SD card slots 0 0 0

6AV6647-0AF11-3AX0 Page 2/ 9

07/11/2013

subject to modifications Copyright Siemens AG 2013

Number of parallel interfaces Number of 20 mA interfaces (TTY) Number of RS 232 interfaces Number of RS 422 interfaces Number of other interfaces With software interfaces

0 0 0 0 0 No

Industrial Ethernet
Number of industrial Ethernet interfaces Industrial Ethernet status LED 1 2

Protocols
PROFINET Supports protocol for PROFINET IO IRT supported PROFIBUS MPI Yes No No No No

Protocols (Ethernet)
TCP/IP DHCP SNMP DCP LLDP Yes Yes Yes Yes Yes

WEB characteristics
HTTP HTML No No

Further protocols
CAN MODBUS Supports protocol for EtherNet/IP No Yes ; Modicon (MODBUS TCP/IP) Yes

Interrupts/diagnostics/status information Diagnostic messages


Diagnostic information readable No

Degree and class of protection


Type of protection IP (at the front) Enclosure Type 4 at the front Enclosure type 4x at the front IP20 IP65 Yes Yes

Standards, approvals, certificates


CE Yes

6AV6647-0AF11-3AX0 Page 3/ 9

07/11/2013

subject to modifications Copyright Siemens AG 2013

KC approval cULus C-TICK GL ABS BV DNV LRS Class NK PRS

Yes Yes Yes Yes Yes Yes Yes Yes Yes No

Use in hazardous areas


ATEX Zone 2 ATEX Zone 22 cULus Class I Zone 1 cULus Class I Zone 2, Division 2 FM Class I Division 2 No No No No No

Ambient conditions
Mounting position maximum permissible angle of inclination without external ventilation vertical 35

Operating temperature
Operation (vertical installation) in vertical mounting position/ minimum in vertical mounting position/ maximum Operation (max. tilt angle) at maximum tilt angle/minimum at maximum tilt angle/maximum 0 C 40 C 0 C 50 C

Storage/transport temperature
Min. max. -20 C 60 C

Relative humidity
max. relative humidity 90 %

Operating systems
Windows CE proprietary other No Yes No

Configuration
Message indicator With alarm logging system (incl. buffer and acknowledgment) Yes Yes

6AV6647-0AF11-3AX0 Page 4/ 9

07/11/2013

subject to modifications Copyright Siemens AG 2013

Process value display (output) Process value default (input) possible Recipe administration

Yes Yes Yes

Configuration software
STEP 7 Basic (TIA Portal) STEP 7 Professional (TIA Portal) WinCC flexible Compact WinCC flexible Standard WinCC flexible Advanced WinCC Basic (TIA Portal) WinCC Comfort (TIA Portal) WinCC Advanced (TIA Portal) WinCC Professional (TIA Portal) Yes ; via integrated WinCC Basic (TIA Portal) Yes ; via integrated WinCC Basic (TIA Portal) Yes Yes Yes Yes Yes Yes Yes

Languages Online languages


Number of online/runtime languages 5

Languages
Languages per project Languages D GB F I E Chinese traditional Chinese simplified DK FIN GR J KP / ROK NL N PL P RUS S CZ SK Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 32

6AV6647-0AF11-3AX0 Page 5/ 9

07/11/2013

subject to modifications Copyright Siemens AG 2013

TR H

Yes Yes

Functionality under WinCC (TIA Portal)


Libraries Task planner time-controlled task-controlled No Yes Yes

With alarm logging system (incl. buffer and acknowledgment)


Number of alarm classes Number of bit messages Number of analog messages System messages HMI Number of characters per message Number of process values per message Message indicator Message buffer Number of entries Circulating buffer retentive maintenance-free 256 Yes Yes Yes 32 200 15 Yes 80 8 Yes

Recipes
Number of recipes Data records per recipe Entries per data record Size of internal recipe memory Recipe memory expandable 5 20 20 40 kbyte No

Variables
Number of variables per device Number of variables per screen Limit values Multiplexing Structs Arrays 500 30 Yes Yes No Yes

Images
Number of configurable images Permanent window/default Global image Start screen configurable Image selection by PLC 50 Yes Yes Yes Yes

6AV6647-0AF11-3AX0 Page 6/ 9

07/11/2013

subject to modifications Copyright Siemens AG 2013

Image number in the PLC

Yes

Image objects
Number of objects per image Text fields I/O fields Graphic I/O fields (graphics list) Symbolic I/O fields (text list) Date/time fields Switch Buttons Graphic view Icons Geometric objects 30 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Complex image objects


Number of complex objects per screen Alarm view Trend view User view Status/control Sm@rtClient view Recipe view f(x) trend view System diagnostics view Media Player Bar graphs Sliders Pointer instruments Analog/digital clock 5 Yes Yes Yes No No Yes No No No Yes No No No

Lists
Number of text lists per project Number of entries per text list Number of graphics lists per project Number of entries per graphics list 150 30 100 30

Archiving
Number of archives per device 0

Security
Number of user groups Number of user rights Number of users 50 32 50

6AV6647-0AF11-3AX0 Page 7/ 9

07/11/2013

subject to modifications Copyright Siemens AG 2013

Password export/import SIMATIC Logon

No No

Character sets
Keyboard fonts US English Character sets Tahoma Arial Courier New WinCC flexible Standard Ideographic languages Font size freely scalable Additional character sets can be loaded Yes No No Yes Yes No No Yes

Transfer (upload/download)
MPI/PROFIBUS DP USB Ethernet using external storage medium No No Yes No

Process coupling
S7-1200 S7-1500 S7-200 S7-300/400 LOGO! Win AC SINUMERIK SIMOTION Allen Bradley (EtherNet/IP) Allen Bradley (DF1) Mitsubishi (MC TCP/IP) Mitsubishi (FX) OMRON (FINS TCP) OMRON (LINK/Multilink) Modicon (Modbus TCP/IP) Modicon (Modbus) Yes Yes Yes Yes Yes Yes No No Yes No Yes No No No Yes Yes

Service tools/configuration aids


Clean screen Touch calibration Backup/restore Yes Yes Yes

6AV6647-0AF11-3AX0 Page 8/ 9

07/11/2013

subject to modifications Copyright Siemens AG 2013

Backup/Restore automatically Simulation Device switchover Delta transfer

No Yes Yes No

I/O / Options
I/O devices Printer Multi Media Card SD card USB memory No No No No

Mechanics/material
Type of housing (front) Plastic Aluminum Stainless steel Yes No No

Dimensions
Width of the housing front Height of housing front Mounting cutout (W x H x D) Mounting cutout, width Mounting cutout, height Depth/installation dimension 310 mm 248 mm 60 mm 335 mm 275 mm

Weight
Weight without packaging Weight incl. packaging Status 2.65 kg 3.38 kg Jul 10, 2013

6AV6647-0AF11-3AX0 Page 9/ 9

07/11/2013

subject to modifications Copyright Siemens AG 2013

Anda mungkin juga menyukai