Anda di halaman 1dari 8

User Manual for

Joerns EasyCare 2100


Model B694

To avoid injury, read manual before using bed.

Important Warnings
WARNING: POSSIBLE INJURY. Before adjusting bed, check that nothing is under or near the bed. Keep children and pets away from the bed to prevent injury. WARNING: POSSIBLE INJURY. Keep bed in lowest position except for providing care (bathing, clothing changes, etc.). Entering or exiting a raised bed could result in falls or injuries. WARNING: POSSIBLE INJURY. Injury may result from improper use of bed accessories (patient restraints, side rails, trapeze devices, etc.). Consult the accessory manufacturer for proper use instructions. WARNING: POSSIBLE SHOCK HAZARD. Bed power cord has a hospital grade 3prong grounding plug. Connect only to a hospital grade 3-prong outlet. Do not defeat grounding safety feature by using a 3-prong to 2-prong adapter. If necessary, have outlet ground reliability checked by a qualified electrician. WARNING: POSSIBLE SHOCK HAZARD. The motor control box does not contain serviceable parts. Unplug the bed if there is a malfunction. Refer servicing to qualified personnel. WARNING: POSSIBLE FIRE HAZARD. Use nasal mask or 1/2 bed tent oxygen administering equipment. Oxygen tent should not extend below mattress support. WARNING: POSSIBLE INJURY. Unplug power cord from wall outlet before using emergency crank. Injury could result if power resumes while cranking. WARNING: POSSIBLE SHOCK HAZARD. Unplug power cord from wall outlet before performing any maintenance or service to the power box. WARNING: POSSIBLE FIRE HAZARD. Pendant should not be placed in an oxygen enriched environment such as an oxygen tent. WARNING: POSSIBLE INJURY OR DEATH. Use a mattress thick enough and wide enough so that the gap between the top of the mattress and the bottom of the side rail is small enough to prevent a patient from getting their head between the mattress and the side rail and possibly suffocating. WARNING: POSSIBLE INJURY . Floor locks increase bed stability and resident safety, decreasing the liability of a nursing home. Sunrise Medical strongly recommends using floor locks on all beds. WARNING: POSSIBLE INJURY. Do not mount trapeze to headboard. When mounting a trapeze, use a trapeze adapter supplied by Sunrise Medical. WARNING: POSSIBLE SHOCK HAZARD. Injury may result from improper routing of the power cord. Refer to service manual for proper routing schematic.
2

Thank you and congratulations for choosing the Joerns

EasyCare 2100 bed.

The Joerns EasyCare 2100 was developed to provide comfort and ease of operation for patients and caregivers. Its dependable design will provide years of trouble free operation. The 2100 is uniquely suited for use in health care institutions and alternate care settings.

Table of Contents
Important Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Features and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Side Rails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Bed Identification Numbers


When ordering parts, or when contacting our Customer Care Department, please include the Model and Serial Numbers of the bed, found on the identification label. The identification label is located on the frame of the bed under the foot section of the sleep deck. Your bed warranty information appears on the back cover of this manual.

Bed Weight Capacity


The Joerns EasyCare 2100 bed has a capacity of 500 pounds distributed evenly on the sleep surface. This is the total weight of the resident, mattress, bedding, accessories and other medical equipment in use. Do not use water mattresses that allow water to flow to the foot end when the head is raised.

Questions?
If you have any questions about your new Joerns EasyCare bed or any other Joerns product, contact our Customer Care Department at:

Sunrise Medical 5001 Joerns Drive Stevens Point, Wl 54481 USA

Phone: (800) 826-0270 Fax: (715) 341-3962 Please have the Model and Serial Number of the product available.

Copyright 2001 Sunrise Medical, Inc. All rights reserved. Publisher reserves the right to make dimension or specification changes, or deletions, consistent with design trends, product improvements, or for reasons beyond our control. Publisher makes no warranties with respect to the accuracy or completeness of the contents of this manual. Joerns and EasyCare are trademarks of Sunrise Medical, Inc.; other trademarks used in this document are property of their respective trademark holders.

Joerns EasyCare 2100


Joerns EasyCare Standard Features
76 or 80 Sleep Surface Pendant Full Frame Traction Capability Grip Lock Staff Control Trendelenburg Control Mechanism

Accessories and Options


Baseboard Bumper Trapeze Bar Adapter Emergency Crank IV Rod Bed Panels 84 Extender Pan Fabric 1/2, 3/4 or Full length rails

Operation of Your New Joerns EasyCare 2100 Bed


Operation of the Electronic Controls Your Joerns EasyCare 2100 comes with both a pendant control and staff control, so the bed can be controlled by either the resident or by a staff member. The pendant is white in color with high-contrast, easy-to-read graphics. It is water resistant and comes standard with a coiled cord. The pendant can be snapped onto the side rail.

Pendant Lockout Operation 1 - Push button to lockout Head 2 - Push button to lockout Knee 3 - Push button to lockout Hi/Lo 4 - Push button to unlock Head 5 - Push button to unlock Knee 6 - Push button to unlock Hi/Lo

Bed Operation 7 - Push button to raise Head 8 - Push button to lower Knee 9 - Push button to raise Knee 10 - Push button to lower Knee 11 - Push button to raise Bed 12 - Push button to lower Bed

Head Operation 1 - Push button to raise Head 2 - Push button to lower Head Knee Operation 3 - Push button to raise Knee 4 - Push button to lower Knee Bed Height Operation 5 - Push button to raise Bed 6 - Push button to lower Bed

The Staff Control allows the caregiver to individually lockout all functions of the pendant control. The caregiver can also operate the bed from this panel without walking to the side of the bed. To lockout a function, press the no pendant graphic on the panel. The illuminated red LED indicates that the function is now locked out. To unlock the function, press the pendant graphic on the panel. The red LED is no longer illuminated, signaling that the pendant can operate that function.
4

Operation of the Trendelenburg Control System


Trendelenburg (Feet Raised) 1. Lower head and knee to flat position with either pendant or Staff Control. 2. Raise bed to highest position. 3. Slide silver lever of Trendelenburg control to the right and engage in detent. (figure 3) 4. Lower the bed with either the pendant or Staff Control system to desired Trendelenburg angle.

Fig. 3

Normal Position 1. Raise bed to highest position with the Staff Control from either Trendelenburg or Reverse Trendelenburg, 2. Disengage black or silver lever from detent and return it to its normal position. (figure 4) 3. Lower bed to lowest level for resident's safety with Staff Control system.

Fig. 4

Reverse Trendelenburg (Head Raised) 1. Lower head and knee to flat position with either the Pendant or Staff Control. 2. Raise bed to highest position. 3. Slide black lever of the Trendelenburg control to the left and engage in detent. (figure 5). 4. Lower the bed with either the pendant or Staff Control system to desired angle.

Fig. 5

Operation of the Grip Lock


To lock the bed, step on the red pedal. To unlock casters, step on the green pedal. (figure 6)

Fig. 6

Side Rail Models for the EasyCare 2100 Bed


Sunrise Medical offers several side rail designs for Joerns beds. Rotating side rails are easily raised or lowered with one hand. This leaves the other hand free to assist the patient or to hold medicines or meals.

Half Rails
The most flexible option is the rotating half rails. These rails come in sets of two, and are available for the head section only, or for extra protection, both head and foot sections. All four sections can be raised or lowered individually. This permits a wide range of patient protection or freedom as needs change.(figure 7)

Fig. 7

3/4 and Full Length Rails


Sunrise Medical also offers full or 3/4 length rails for greater patient protection. Remember, always use a mattress thick enough and wide enough so that the gap between the top of the mattress and the bottom of the rail is small enough to prevent a patient from getting their head between the mattress and side rail and possibly suffocating.(figure 8)
Fig. 8

WARNING: POSSIBLE INJURY. Injury may result from improper use of bed accessories (patient restraints, side rails, trapeze devices, etc.). Consult the accessory manufacturer for proper use instructions.

Cleaning and Sanitizing Your Joerns EasyCare 2100 Bed


WARNING: POSSIBLE SHOCK HAZARD. Unplug the power cord of electric beds before cleaning with water based solutions.

CAUTION: Possible damage to electrical parts.


Clean all electrical components (motors, control box, pendant and cords) on your Joerns EasyCare 2100 bed with a damp, well-wrung out cloth. Excess water in or on electrical parts could damage these components. Do not submerge the pendant in liquid. The Joerns EasyCare 2100 bed has a durable, baked-on epoxy finish that is easily cleaned with a mild solution of antiseptic cleaner (like Lysol) and warm water. Read and follow all label instructions on the cleaning products. Wood grain surfaces are maintained by cleaning with furniture polish or lemon oil.

Notes

SUNRISE MEDICAL PRODUCT ASSURANCE WARRANTY PROGRAM


Sunrise Medical products are guaranteed for a period of 12 months from the date of delivery against defects in materials and workmanship under normal use and service.
Steel structural components and welds on beds are covered under warranty for a period of ten years from the date of delivery. This warranty does not apply to damage or defects caused by misuse, incorrect handling, or installation by a non-authorized installer. Damaged caused by use in unsuitable environmental conditions or failure to maintain the product in accordance with user and service instructions is not covered. Any alteration, modification, or repair unless performed by or authorized in writing by Sunrise Medical will void this warranty. servicing, or replacing, at its option, any product which is, found by Sunrise Medical to be defective. Warranty replacement parts are covered by the terms of this warranty until the product's original warranty period expires. When requested by Sunrise Medical, parts must be returned for inspection at the customer's expense. Credit will be issued only after inspection.

Warranty
for all Joerns beds including UltraCare, FreeStyle, EasyCare series (manual and electric), Safe-Height, and others Technical Support Hotline (888) 528-8799 Technical Support Fax (715) 341-3603

Service
Most service requests can be handled by the facility Maintenance Department with assistance from the Sunrise Medical Product Service Department. Most parts requested can be shipped UPS next day air at the customer's expense. Should a technician be required, at our discretion, one will be provided by Sunrise Medical. Only the Sunrise Medical Product Service Department can dispatch authorized technicians.

Parts
The product contains various parts that wear from normal use. These parts, such as DC batteries, are not covered under the 12-month warranty but are covered for 90 days after purchase of product. Sunrise Medical's obligation under this warranty is limited to supplying replacement parts,

2001 SUNRISE MEDICAL, INC. 03/01 LITHO U.S .A. Part #6110002C

5001 Joerns Drive Stevens Point, WI 54481 USA (800) 826-0270 Customer Service (715) 341-3600 General Phone (715) 341-3962 General Fax

Anda mungkin juga menyukai