Anda di halaman 1dari 6

Sun x86 Firmware (ILOM/BIOS) Update Procedure

This articles describes SUN x86 Firmware Patches/Updates procedure. This method of updating firmware patch is called Remote Flashing image method. In Sun Fire X4xxx series server with firmware that resides in the following locations: Server motherboard (system BIOS) Servers Service Processor (ILOM) On-board LSI disk controller (HBA BIOS) Among these BIOS/ILOM are always updated together, We can update both ILOM and BIOS firmware even if one of their versions has not changed since the last software update.

Step 1 Download the corresponding latest patches/updates from the Oracle downloads page. http://www.oracle.com/technetwork/systems/patches/firmware/index.html Step 2 Ensure that you have the file: ILOM-3_0_6_15_d_r67788-Sun_Fire_X4150_X4250_X4450.pkg on the PC that will access the ILOM web GUI. Also ensure the MD5 hash of the downloaded file is same as provided. If you have RSG access or Remote desktop access, you have to upload the above Firmware package on the respective server whose Firmware will be upgraded using data IP. Step 3 We have to login in Sun X 4250 ILOM and once we got the prompt then we have to check the existing Firmware version by executing the following command version now check the network status by executing the following command cd /SP showspnetwork

Step 4 Start the Intergrated LOM SP web GUI by typing the IP address of the SP into a browser.

Step 5 Log in to the SP, and backup the current configuration

Using the option Backup/Restore in Maintenance tab, Select a transfer method from the Transfer Method drop-down list as "Browser". With the Browser transfer method, the backup file is saved according to your web browser settings. Step 5 Click on the Maintenance Tab and choose Enter Upgrade Mode

Step 6 Click Browse and navigate to the location of the flash file

Step 7 Click Upload

Step 8 Once the firmware is uploaded, you will be asked to confirm the upgrade, as the current firmware and future firmware versions will be displayed. Please capture screenshot before proceeding. You will be presented with a screen that asks if you want to preserve or Not to preserve the current Settings, and if you want to delay BIOS upgrade until next server poweroff. Please Choose Preserve and do NOT delay BIOS upgrade Now in the ILOM command prompt we have to shutdown the OS by the following command Stop force /SYS Once the OS is shutdown then go for the next step. Step 9 Click "Start Upgrade". The BIOS and SP firmware on the Sun Fire X4150/X4250/X4450 server will be updated.

Step 10 Now click the Reconnect link and login again to ILOM gui. Step 11 Log in to the SP and check the ILOM and BIOS version. In the command prompt of ILOM, start the OS by the following command Start /SYS Check My Next article on Sun SPARC Firmware update

Anda mungkin juga menyukai