Anda di halaman 1dari 5

SECTION 09510 ACOUSTICAL CEILING 00000000PART 1 - GENERAL 1.1 SECTION INCLUDES A. B. C. 1.

2 Grid suspension system for acoustical ceiling. Mineral fiber acoustical ceiling tiles as shown on the Drawings and as specified herein. Acoustical ceiling panels as shown on the Drawings and as specified in this section.

REFERENCES A. ASTM - American Society for Testing and Materials ASTM A 446 ASTM A 525 ASTM A 614 ASTM C 423 ASTM C 523 ASTM E 90 ASTM E 84 ASTM C 635 ASTM C 636 ASTM C 637 B. Steel Sheet, Zinc-Coated (Galvanized) by the Hot-Dip Process, Structural Quantity Steel Sheet Zinc-Coated (Galvanized) by Hot-Dip Process Zinc-Coated (Galvanized) Carbon Steel Wire Test for Sound Absorption Reverberation Rooms of Acoustical Materials in

Light Reflectance of Acoustical Material Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions Test for Surface Burning Characteristics of Building Materials Specification for Metal Suspension Systems for Acoustical Tile and Lay-In Panel Ceilings Recommended Practice for Installation of Metal Ceiling Suspension System for Acoustical Tile and Lay-In Panels Tests for Strength Properties of Prefabricated Architectural Acoustical Materials

UL - Underwriters Laboratories, Inc. UL Fire Resistance Directory, 1989 Edition

1.3

SUBMITTALS

ITCC in Riyadh Residential Complex J10-13300

09510-1

Acoustical Tiles

A. B. 1.4

Samples of grid system components and ceiling tiles. Certification that the components meet the requirements and tests specified.

TRANSPORTATION, HANDLING AND STORAGE A. Deliver acoustical ceiling units to project site in original, unopened packages and store them in fully enclosed space where they will be protected against damage from humidity, direct sun light, surface contamination, and other causes. Handle acoustical ceiling units carefully to avoid chipping edges or damaging units in any way.

1.5

WARRANTY A. Submit written guarantee signed by the contractor and manufacturer for 1 year from the date of substantial handover. Guarantee shall cover repair and replacement of defective material and workmanship.

1.6

QUALITY ASSURANCE A. Engage an experience installer who has successfully completed acoustical ceilings similar in material, design and extent to that indicated for the Project.

1.7

PROJECT CONDITIONS A. Do not install acoustical materials unless temperature and humidity conditions closely approximate the interior conditions which will exist when the building is occupied. Maintain temperature and humidity conditions during and after installation. Plastering, concrete and terrazzo work (including grinding) shall be completely dry. Windows and doors shall be in place and glazed.

PART 2 - PRODUCTS 2.1. SUSPENSION SYSTEM A. Suspension System: Manufacturer's standard exposed grid system designed and fabricated to meet requirements of ASTM C 635 with UL classification as approved by the Engineer. Materials: Double-web, cold-rolled electro-galvanized steel with the following features: Face Dimension: 15/16 Profile: Exposed Tee Color: As selected by the Engineer from the Manufacturer's standard range of products Finish: Baked polyester paint

B.

C. D.

Hanger Wires: Galvanized steel wires, pre-stretched, 2.8 mm diameter. Hanger Wire Anchors: Drill-in type as approved by the Engineer.

ITCC in Riyadh Residential Complex J10-13300

09510-2

Acoustical Tiles

E. 2.2.

Accessories: Edge Moldings, hold-down clips and other necessary accessories shall be provided in accordance with the Engineer's selection and approval.

ACOUSTICAL CEILING TILE A. Tile Construction: Wet-formed mineral fiber composition conforming to ASTM E 1264 or Federal Specifications FS-SS-S-118B, Type III, form 1 units; Class A with an STC Range from 35 - 40; Flame Spread of 0 - 25 and Smoke Developed 0 - 50 in accordance with ASTM E 84. B. Profiles: Square-cut and Beveled Tegular, lay-in type. Sizes: 600 x 600 mm as indicated on Drawings. Thickness: Not less than 19 mm. Finish: Factory-applied washable white finish with light reflectance value of LR-1 (over 75 percent).

Access Hatches: Provide manufacturer standard access hatches which are designed specially for the acoustical ceiling systems. Provide the access hatches with complete features including door locks, frames, pivots, metal trims and gaskets. Broad Spectrum Antimicrobial Fungicide and Bactericide Treatment: Provide acoustical tiles treated with manufacturer's standard antimicrobial formulation that inhibits fungus, mold, mildew, and gram-positive and gram-negative bacteria and showing no mold, mildew, or bacterial growth when tested according to ASTM D 3273 and evaluated according to ASTM D 3274 or ASTM G 21.

C.

2.3.

ACOUSTICAL CEILING PANELS A. Acoustical Panel Standard: Provide manufacturer's standard panels of configuration indicated that comply with ASTM E 1264 classifications as designated by types, patterns, acoustical ratings, and light reflectance, unless otherwise indicated. Subparagraph below represents standard mounting referenced in ASTM e 1264. Revise if testing units with another mounting method is required for Project. Mounting Method for Measuring Noise Reduction Coefficient: Type E-400; plenum mounting in which face of test specimen is 15-3/4 inches (400 mm) away from test surface per ASTM E 795. Acoustical Panel Colors and Patterns: Match appearance characteristics indicated for each product type. Where appearance characteristics of acoustical panels are indicated by referencing ASTM E 1264 pattern designations and not manufacturers' proprietary product designations, provide products selected by Architect from each manufacturer's full range of products that comply with requirements indicated for type, pattern, color, light reflectance, acoustical performance, edge detail, and size. Treatment below is available from armstrong world Industries and USG interiors for some panel products. If paragraph is retained, correlate with panel product
09510-3 Acoustical Tiles

B. C.

D. E.

F.

ITCC in Riyadh Residential Complex J10-13300

characteristics in schedule. Delete if not needed or if treatment is not available for product selected. G. Antimicrobial Treatment: Provide acoustical panels treated with manufacturer's standard antimicrobial solution consisting of a synergistic blend of substituted ammonium salts of alkylated phosphoric acids admixed with free alkylated phosphoric acid that inhibits fungus, mold, mildew, and gram-positive and gramnegative bacteria. Panel Characteristics: Comply with requirements indicated in the Acoustical Panel Ceiling Schedule at the end of Part 3, including those referencing ASTM E 1264 classifications. Vibration Isolation: Provide manufacturer's standard vibration isolation units at hangers as required . Installation: Install acoustical tile ceilings to comply UBC, ASTM C 636, manufacturer's written instructions and CISCA's "Ceiling Systems Handbook." Provide edge moldings, hold-down clips and other necessary accessories as required.

H.

I. J.

PART 3 - EXECUTION 3.1 INSTALLATION A. The installation of all exposed grid acoustical work covered in this section shall be done by a qualified acoustical subcontractor recommended by the manufacturer, having at least 5 years experience in successfully completed projects.

3.2

SUSPENSION SYSTEM A. B. Installation of suspension system shall be in accordance with ASTM C 636 and in accordance with manufacturer's directions. Rough Suspension: 1. 2. 3. 4. C. D. Space hanger wires at 1200 mm on centers, each direction. Supported from structural angle runners by looping and wire-tying. Hangers shall be installed at ends of each suspension member and at light fixtures, 150 mm from vertical surfaces. Wires shall not be splayed more than 125 mm in a 1200 mm vertical drop. Wire shall be wrapped a minimum of three times horizontally, turning the ends upward.

System shall be level within tolerance specified and parallel with walls. Wall moldings shall be installed at intersection of suspended ceiling an vertical surfaces. 1. Corners shall be mitered where wall moldings intersect or corner caps shall
09510-4 Acoustical Tiles

ITCC in Riyadh Residential Complex J10-13300

be installed in lieu thereof. 2. 3. 3.3 Continuous ribbon of acoustical adhesive or caulking compound shall be applied on vertical web. Attachment to vertical surface shall be by means of mechanical fasteners.

CEILING TILES A. B. C. Installation of acoustical ceilings shall not begin until the building has been closed to weather with Relative Humidity not more than 70 percent. Ceiling tiles shall be in a leveled plane and in straight line courses. Provide cutting and patching for the passage of materials of other trades.

3.4

CLEANING A. Clean exposed surfaces of acoustical ceiling including trims, edges, moldings and suspension members. Comply with manufacturer's instructions for cleaning and touch-up of minor finish damage. Remove and replace work which cannot be successfully cleaned and repaired to permanently eliminate evidence of damage. END OF SECTION

ITCC in Riyadh Residential Complex J10-13300

09510-5

Acoustical Tiles