Users Guide
User Guide
www.nec-computers.com
Table of Contents
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Text Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
European Notice ............................................................................................................ USA and Canada Notice ................................................................................................ Modifications to the Product.......................................................................................... Connections and Remote Earths .................................................................................... Power Supply and Cables .............................................................................................. Batteries ......................................................................................................................... Chassis Cover Removal and Replacement .................................................................... Laser Compliance Statement ......................................................................................... Warning - Hazardous Voltage! ...................................................................................... Warning -Avoid Electrostatic Discharge!...................................................................... Product Disposal ............................................................................................................
11 11 12 12 12 13 13 13 14 14 14
Power Lamp................................................................................................................... Access Lamp.................................................................................................................. LAN Connector Lamps.................................................................................................. Internal View ................................................................................................................. Motherboard................................................................................................................... Configuring MotherBoard Jumpers ............................................................................... Back Panel Connectors .................................................................................................. Processor........................................................................................................................ Memory.......................................................................................................................... PCI Slots ........................................................................................................................ PCI -E xpress Slots ........................................................................................................ Network Controller ........................................................................................................ ACPI .............................................................................................................................. Keyboard and Mouse ..................................................................................................... Peripheral Bays .............................................................................................................. Power Supply................................................................................................................. Peripheral Bays ..............................................................................................................
Optional Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CD-ROM Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DVD-ROM Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DVD +R9 Combination Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DVD+R9 (DL) Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DAT72 Tape Backup Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sony AIT-E Turbo Backup Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sony AIT-1 Turbo Backup Unit (SCSI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sony AIT-1 Turbo Backup Unit (IDE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sony AIT-2 Turbo Backup Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LTO 2 Tape Drive (SCSI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20 20 20 21 22 23 24 25 25 25 25 26 26 27 27 28 28
29 30 31 32 33 35 36 37 38 39 40
Standard Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
User Guide
www.nec-computers.com
Intel Pro 1000 MT LAN Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 PCI-E x1 Syskonnect LAN Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 S-ATA Hard Disk Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Highlights....................................................................................................................... 55 Specifications................................................................................................................. 56
Adaptec SCSI Card 29160ALP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Highlights....................................................................................................................... 58 Specifications................................................................................................................. 58
Adaptec SCSI Card 29320ALP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Highlights....................................................................................................................... 59 Specifications................................................................................................................. 59
SCSI Card SecuRAID 114 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Highlights....................................................................................................................... 60 Features.......................................................................................................................... 60
Unpacking the Rack Installation Kit.............................................................................. Before You Begin .......................................................................................................... Static Precautions........................................................................................................... Assembly ....................................................................................................................... Installing the Support Rails............................................................................................ Attaching the Handles to the Rack Mounting Frame .................................................... Installing the Rack Mounting Frame on the Server....................................................... Installing the Server in the Rack Cabinet ......................................................................
66 67 67 67 69 70 70 72
User Guide
www.nec-computers.com
FastTrak BIOS ............................................................................................................... View Drive Assignments ............................................................................................... Create a Logical Drive................................................................................................... Delete Logical Drive...................................................................................................... Controller Configuration................................................................................................ Logical Drive Problems ................................................................................................. Description..................................................................................................................... Enabling RAID in the BIOS .......................................................................................... Entering the Intel Matrix Storage Manager ................................................................... Creating a RAID Volume .............................................................................................. Deleting a RAID Volume .............................................................................................. Resetting Disks to Non-RAID .......................................................................................
87 88 88 90 90 91 92 92 92 92 93 94
Installing the Hard Disk Drives ..................................................................................... 95 Enabling the RAID Feature using the SCSISelect Utility ............................................. 95 Creating Arrays............................................................................................................ 100
RAID Configuration using the MegaRAID Configuration Utility . . . . . . . . . . . . . . . . . . . . . . 110
Removing the Right Side Door.................................................................................... 114 Replacing the Right Side Door .................................................................................... 115
Removing and Replacing the Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Removing the Front Panel ........................................................................................... 116 Replacing the Front Panel............................................................................................ 116
Installing or Removing a 5.25-inch Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Adding a 5.25-inch Device .......................................................................................... 117 Removing a 5.25-inch device ...................................................................................... 118
Installing or Removing a 3.5-inch Floppy Disk Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
Removing a 3.5-inch Floppy Disk Drive..................................................................... 119 Installing a 3.5-inch Floppy Disk Drive ...................................................................... 119
Installing or Removing Hard Disk Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
Removing a Hard Disk Drive ...................................................................................... 120 Installing a Hard Disk Drive........................................................................................ 121
Installing and Removing the Hard Disk Drive Cage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Installing the Hard Disk Drive Cage............................................................................ 123 Removing the Hard Disk Drive Cage .......................................................................... 124
Cabling the Hard Disk Drive Cage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
User Guide
www.nec-computers.com
Recommended Memory Configuration ....................................................................... 129 Checking System Memory........................................................................................... 129 Removing and Replacing a DDR2 module.................................................................. 129
Replacing the Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131 Installing and Removing an Expansion Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
Specific Recommendations.......................................................................................... 132 Installing an Expansion Card....................................................................................... 135 Removing an Expansion Card from Your System....................................................... 137
Cabling IDE Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
The IDE Cable ............................................................................................................. 138 System Power Cables................................................................................................... 139 Cabling an Optical Disk Drive..................................................................................... 139
Cabling SCSI Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
The S-ATA Cable ........................................................................................................ 142 System Power Cables................................................................................................... 142 Cabling a Hard Disk Drive .......................................................................................... 142
Cabling a Floppy Disk Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 Preparing IDE Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
Preparing an IDE Optical Drive................................................................................... 145 Preparing an IDE Tape Drive ...................................................................................... 145
Preparing SCSI Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
Preparing a SCSI Hard Disk Drive .............................................................................. 147 Preparing a SCSI Tape Drive....................................................................................... 147
Preparing SATA Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
EXPRESSBUILDER for DOS-Based with Local Console........................................ 153 EXPRESSBUILDER for DOS-based with Remote Console ...................................... 158 EXPRESSBUILDER for Windows-Based (Master Control Menu)............................ 160
Configuration Diskette Creator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162
Features........................................................................................................................ 166
WebPAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167 Intel Matrix Storage Manager (Windows Interface) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168 Power Console Plus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
User Guide
www.nec-computers.com
Running the SCSISelect Utility ................................................................................... Adaptec SCSI Utility Configuration Settings.............................................................. SCSI Disk Utilities....................................................................................................... Exiting Adaptec SCSI Utility ...................................................................................... Overview of HostRAID ............................................................................................... Overview of the specifications .................................................................................... Features........................................................................................................................ Enabling HostRAID on your system ........................................................................... References.................................................................................................................... Recommendations and Specifics .................................................................................
172 172 173 174 175 175 175 176 176 177
HostRAIDTM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175
Test Items .................................................................................................................... 178 Starting and Ending the System Diagnostics .............................................................. 179
Installation Notice........................................................................................................ 182 Windows Server 2003 or Windows XP Professional .................................................. 182 Installing Windows Server 2003 or Windows XP Professional .................................. 184
Installing Drivers or Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186
Using Passwords .......................................................................................................... 189 Secure Mode ................................................................................................................ 190 Software Security Features .......................................................................................... 190
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .193
Making Backup Copies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194
Cleaning the External Surfaces of the system ............................................................ Cleaning the Interior of the system.............................................................................. Cleaning the Keyboard ................................................................................................ Cleaning the Mouse ..................................................................................................... Cleaning an Optical Drive and CD-Rom/CD-RW/DVD-Rom....................................
Problems with Express Server ..................................................................................... Problems with Windows Server 2003 ......................................................................... Problems with EXPRESSBUILDER........................................................................... Problems with Express Setup ...................................................................................... Problems with Disk Array Configuration ................................................................... Problems with Master Control Menu .......................................................................... Problems with Configuration Diskette Creator ........................................................... Problems with Disk Array Configuration....................................................................
Collecting Event Log
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
User Guide
www.nec-computers.com
Collecting Configuration Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214 Collecting Dr. Watson Diagnostic Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215 Memory Dump (depending on your configuration) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
Preparing for Memory Dumping ................................................................................. 216 Saving the Dump File .................................................................................................. 216
Off-Line Maintenance Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218
Starting the Off-line Maintenance Utility.................................................................... 218 Off-line Maintenance Utility Features......................................................................... 219
If You Need Assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Diagnostics Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Problems at initial System Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Problems After the System Has Been Running Correctly . . . . . . . . . . . . . . . . . . . . . . . . . . . Problems Running New Application Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221 224 225 226 227 228
Standard BIOS Features Menu .................................................................................... Boot Configuration Features Menu ............................................................................. Advanced BIOS Features Menu .................................................................................. Advanced Chipset Features Menu ............................................................................... Power Management Features Menu ............................................................................ Hardware Health Configure Menu .............................................................................. BIOS Security Features Menu ..................................................................................... Exit Options on the Main Menu ..................................................................................
User Guide
www.nec-computers.com
10
Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials, is the valuable property of NEC Computers International and/or its licensors. NEC Computers International and/or its licensors, as appropriate, reserve all patent, copyright and other proprietary rights to this document, including all design, manufacturing, reproduction, use, and sales rights thereto, except to the extent said rights are expressly granted to others. The NEC Computers International product(s) discussed in this document are warranted in accordance with the terms of the Warranty Statement accompanying each product. However, actual performance of each product is dependent upon factors such as system configuration, customer data, and operator control. Since implementation by customers of each product may vary, the suitability of specific product configurations and applications must be determined by the customer and is not warranted by NEC Computers International. To allow for design and specification improvements, the information in this document is subject to change at any time, without notice. Reproduction of this document or portions thereof without prior written approval of NEC Computers International is prohibited.
Trademarks Adobe, and Adobe Acrobat are registered trademarks of Adobe Systems, Incorporated. Microsoft, Microsoft Windows, Windows NT, Windows 95, Windows 98, Windows 2000 and Windows Storage Server 2003 are all registered trademarks of Microsoft Corporation. MS-DOS is a registered trademark of Microsoft Corporation. Intel and Pentium are registered trademarks of Intel Corporation. All other product, brand, or trade names used in this publication are the trademarks or registered trademarks of their respective trademark owners. rev 0.0 July 2005
Copyright 2005 NEC Computers International B.V. Nieuweweg 279 6603 BN Wijchen The Netherlands All Rights Reserved
User Guide
www.nec-computers.com
Text Conventions
This guide uses the following text conventions. Warnings, cautions, and notes have the following meanings:
Warning
Warnings alert you to situations that could result in serious personal injury or loss of life.
Caution
Cautions indicate situations that can damage the system hardware or software.
Names of keyboard keys are printed as they appear on the keyboard. For example, Ctrl, Alt, or Enter. Text or keystrokes that you enter appear as boldface type. For example, type abc123 and press ENTER. File names are printed in uppercase letters. For example, AUTOEXEC.BAT.
10
User Guide
www.nec-computers.com
Safety Notices
Caution
To reduce the risk of electric shock which could cause personal injury, follow all the safety notices. Symbols are shown in your documentation and on your equipment to indicate safety hazards.
Regulatory Information
European Notice
Products with the CE marking comply with both the Electromagnetic Compatibility Directive (89/336/EEC) and the Low Voltage Directive (73/23/EEC) - modified by the Directive 93/68/ECC - issued by the Commission of the European Community. Compliance with these directives implies conformity to the following European Standards: EN55022: Radio Frequency Interference EN55024 (1998+A1:2001): Immunity characteristics EN6100-3-2: Limits for harmonic current emissions EN6100-3-3: Limitation of voltage fluctuation and flicker in low-voltage supply system EN60950-1 (2001): Product Safety If your system includes a telecommunication network board, the input/output socket is classified as Telecommunication Network Voltage (TNV-3)
11
User Guide
www.nec-computers.com
The equipment has been tested and found to comply with the limits for a Class A or B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.
12
User Guide
www.nec-computers.com
this manual, make sure that your system is powered off and unplug the AC power cords from the back of the chassis. Failure to disconnect power before opening your system can result in personal injury and equipment damage. Under no circumstances should the user attempt to disassemble the power supply. The power supply has no user-replaceable parts. Inside the power supply are hazardous voltages that can cause serious personal injury. A defective power supply must be returned to your dealer. Cables In the U.S.A. and Canada, the power cord must be a UL-listed detachable power cord (in Canada, CSA-certified), type ST or SJT, 16 AWG, 3-conductor, provided with a moulded-on NEMA type 5-15 P plug cap at one end and a moulded-on cord connector body at the other end. The cord length must not exceed 9 feet (2.7 meters). Outside the U.S.A. and Canada, the plug must be rated for 250 VAC, 10 amp minimum, and must display an international agency approval marking. The cord must be suitable for use in the end-user country. Consult your dealer or the local electrical authorities if you are unsure of the type of power cord to use in your country. The voltage change occurs via a switch in the power supply. The detachable power supply cords are intended to serve as the disconnect devices. For PLUGGABLE EQUIPMENT, the socket-outlet shall be installed near the equipment and shall be easily accessible. This equipment has a 3-wire, grounded power cords. To prevent electrical hazards, do not remove or defeat the ground prong on the power cords. Replace a power cord if it gets damaged. Contact your dealer for an exact replacement.
Batteries
Lithium batteries can be dangerous. Improper handling of lithium batteries may result in an explosion. Dispose of lithium batteries as required by local ordinance. Also see Product Disposal on page 14
13
User Guide
www.nec-computers.com
The optical devices installed in your system is designed for use solely as a component of such electronic product and therefore does not comply with the appropriate requirements of Code of Federal Regulation Sec. 1040.10 and Sec. 1040.11 for COMPLETE laser products
Product Disposal
The Waste Electrical and Electronic Equipment (WEEE) Directive requires that used electrical and electronic products must be disposed of separately from normal household waste in order to promote reuse, recycling and other forms of recovery and to reduce the quantity of waste to be eliminated with a view to reduce landfill. WEEE includes accessories such as keyboard, mouse, remote control, speakers, etc... When you dispose of such products, please follow the agreement made between you and NEC and/or your distributor.
14
User Guide
www.nec-computers.com
System Features
The Express5800 TM800 system is a highly flexible and reliable server designed to offer the highest levels of performance at an affordable price. It is: based on the Intel i955X chipset, designed for the Intel Pentium 4, Intel Pentium D or the Intel Celeron D processor, and housed in a tower chassis that can also easily be installed into a standard EIA 19inch rack cabinet. To get comfortable with your computer, take a tour around your system by reading the sections hereafter.
15
User Guide
www.nec-computers.com
Related Documents
In addition to this User Guide, several other documents are included with your system either as electronic files (on the EXPRESSBUILDER CD-ROM) or as paper copy shipped with your server. We recommend you read these additional documents as it becomes necessary when setting up, using or upgrading your server system.
16
User Guide
www.nec-computers.com
17
User Guide
www.nec-computers.com
Rear View
A B C
AC power connector Connect the power cord to this socket. Power switch Key lock and intrusion switch Security feature that allows you to open the right side door and to be noticed when your chassis has been opened
D E F G
Connectors Refer to the System Connectors section hererafter for details. Expansion boards slots Refer to the Expansion Boards Slots section hererafter for details Side cover latch Push the latch up to enable the right side door opening. Venting holes Keep the area near the venting holes clear for proper ventilation.
18
User Guide
www.nec-computers.com
System Connectors
Description
6 Pin Mini-DIN 6 Pin Mini-DIN 25 Pin SUB D 9 pin SUB D
G, H, J, K L M N
Led A Activity
Always ON (orange) Lights OFF when active
Led B Activity
OFF ON (orange) ON (green)
Expansion Board Slots Three PCI expansion slots, one PCI-E x16 expansion slot, one PCI-E x1 expansion slot, and one PCI-E x4 expansion slot are available enabling you to install additional Video Boards and LAN board. Refer to Optional Features on page 29 for details about the components that may be installed in the expansion slots.
19
User Guide
www.nec-computers.com
Status Indicators
This section explains the indication and meanings of the server lamps.
Power Lamp
Lights green to indicate normal operation with the server powered on Remains off when the server is powered off. Blinks green when the server in in a power-saving mode.
Access Lamp
Lights amber when one of the drives is being accessed.
Caution
To indicate the access states of the built-in hard disk drives when an optional board (e.g. disk mirroring controller or disk array controller) is installed, connect the LED cable provided with the server to the LED connector on the motherboard and the optional board.
20
User Guide
www.nec-computers.com
Internal View
21
User Guide
www.nec-computers.com
Motherboard
Name
Power connector Auxiliary Power connector Auxiliary 12v power connector for PCI-Ea CPU fan connector Rear fan connector Front fan connector Floppy drive connector Primary IDE connector PCI connectors PCI-E 1x connector PCI-E 16x connector PCI-E 4x connector CPU connector
Type
20 pin keyed connector 4 pin keyed connector 4 pin keyed connector 3 pin header (white) 3 pin header (white) 3 pin header (white) 34 (2x17) pin shrouded header 40 (2x20) pin header (blue) Standard PCI expansion slots PCI Express expansion slot (white) PCI Express expansion slot (orange) PCI Express expansion slot (blue) LGA 775 socket
22
User Guide
www.nec-computers.com
Name
DDR2 sockets CD-ROM audio line in Connects to the front panel audio Connects to the front panel IEEE1394 port Connects to the front panel USB ports InfraRed (not used) Connect to the SATA hard disk drives Battery socket Clear CMOS jumper 12v standby on board LED Auxiliary thermal diode (not used) Chassis intrusion switch (not used) Front Panel connector Speaker connector (for additional buzzer not used)
Type
184 pin standard sockets 4 pin header (black) 10 pin header (purple) 10 pin header (orange) 2 x 10 pin header (yellow) 6 pin header (black) SATA connector (orange) 3 pin header (pink) Standard LED (orange) 2 pin header (black) 2 pin header (black) 10 pin header (multi coloured) 4 pin header (light green)
a. This connector provides the required additional power when using 75W or greater add-in cards in both the PCI-E x16 and x4 connectors. If possible, plug power cables from the server power supply to the add-in cards. Alternately, use this additional power connector to power the add-in cards. Failure to specifically power 75W or greater add-in cards may damage both the motherboard and the add-in cards.
23
User Guide
www.nec-computers.com
Description
Mouse P/S2 connector Keyboard P/S2 connector Parallel Port Serial Port Mini-IEEE Port RJ-45 Ports USB Ports Audio Line In Audio Line Out Stereo Mic In
24
User Guide
www.nec-computers.com
Standard Features
400W power supply On-board LAN Dual channel memory architecture support SCSI and S-ATA hard disk drives support CD-ROM, DVD-ROM, COMBO DVD-ROM/ CD-RW, DVD+R9 (DL) support PCI and PCI-E x4 support PCI-E x16 video boards support PCI-E x1 LAN board support 5.25-inch tape backup unit support
Processor
The system board may accommodate either: One Intel Pentium 4 processor with up to 2 MB cache, One Intel Pentium D processor with up to 2 x 1 MB cache, Or one Intel Celeron D processor with 256KB cache.
Memory
The system board contains four 240-pins DIMM slots each supporting DDR2 ECC memory. You may install a minimum of 256 MB and as much as 4 GB. Your system supports dual-channel memory architecture. Refer to Recommended Memory Configuration on page 129 for details.
PCI Slots
The motherboard features three standard PCI expansion slots.
25
User Guide
www.nec-computers.com
One PCI-E x4 expansion slot (for a LAN or video board, for instance). One PCI-E x1 expansion slot (for a LAN board, for instance).
Caution
A power connector on the motherboard provides additional power when using 75W or greater add-in cards in both the PCIE x16 and x4 connectors. If possible, plug power cables from the server power supply to the add-in cards. Alternately, use this additional power connector to power the add-in cards. Failure to individually power 75W or greater add-in cards may damage both the motherboard and the add-in cards.
Network Controller
Note: To ensure EMC product regulation compliance, the system must be used with a shielded LAN cable.
The motherboard features the two LAN chipsets below: Realtek 1GB (8118/8110 family) - Integrated 10/100/1000 transceiver - Supports PCI v2.3, 32-bit, 33/66MHz - Supports IEEE 802.3, IEEE 802.3u, IEEE 802.3ab IntelPRO 1000M - Integrated 10/100/1000 transceiver - Supports PCI Express architecture (v1.0a) - Supports Active Management Technology (AMT) - Supports IEEE 802.3, IEEE 802.3u, IEEE 802.3ab
ACPI
The motherboard supports the Advanced Configuration and Power Interface (ACPI) as defined by the ACPI 2.0 specifications. An ACPI aware operating system can put the system into a state where the hard drives spin down, the system fans stop, and all processing is halted. However, the power supply will still be on and the processors will still be dissipating some power, so the power supply fans will still run. The system board supports sleep states s0, s1, s4, and s5:
26
User Guide
www.nec-computers.com
s0: Normal running state. s1: Processor sleep state. No context will be lost in this state and the processor caches will maintain coherency. s3: Suspend to RAM: Your working environment is saved to RAM.
Peripheral Bays
Your system features four 5.25-inch bays that you can use with either a hard disk drive, an optical device such as a CD-ROM, DVD-ROM, a COMBO DVD-ROM CD-RW, a DVD+R9 (DL) or a tape backup unit. You can also use two of these bays to install an optional hot-swap SCSI hard disk drive bay or an optional hot-swap S-ATA hard disk drive bay. See Optional Features on page 29.
27
User Guide
www.nec-computers.com
Power Supply
The system contains one auto-sensing 400-watt power supply at an operating frequency of 50/60 Hz. The power supply is designed to comply with existing emission standards and provide sufficient power for a fully loaded system configuration.
Peripheral Bays
The system supports a variety of standard PC AT-compatible peripheral devices. The chassis includes these peripheral bays: One 3.5-inch file bay for installing the standard 3.5-inch floppy disk drive (supports 720KB and 1.44MB floppy disk media) or an optional file device. Four 5.25-inch file bays for installing half-height 5.25-inch peripheral devices such as optional tape drives (An optical drive is factory-installed). The hard disk drive bays for installing up to four S-ATA or SCSI hard disk drives.
28
User Guide
www.nec-computers.com
Optional Features
You will find hereafter information about the optional components that may be installed in your system. This is not an exhaustive list, some options may not be available anymore, others may have been added.
29
User Guide
www.nec-computers.com
CD-ROM Drive
High Speed CD: 48X max. Buffer: 128 kBytes Emergency Eject: Pin-hole on front panel to release tray. Software Ejection/ Loading and Volume Control Form Factor: 5.25" half height.
Compatibility: Mixed mode CD-ROM disc, CD-DA, Photo-CD Multi-session, CD-ROM XA, CD-I Ready, CD-Plus, CD-Extra, CD-RW. Transfer rate (max): 7200Kbytes/s CD-ROM ATA Interface (burst): - 16.6 Mbytes/s (PIO Mode 4/ MULTI word DMA Mode 2) Rotation Speed: approx.10500 rpm Full Stroke Access Time: 75 ms (typical) Environmental Specifications: Table 5: CD-ROM Drive Environmental Specifications
Operating
Temperature Humidity (% relative humidity) Vibration 0C to 50C 10% to 80% 0.35 G (10-500 Hz)
Non-operation
-40C to +60C 5% to 90% 2.0 G (10-500 Hz)
30
User Guide
www.nec-computers.com
DVD-ROM Drive
High Speed DVD: 16X max & High Speed CD: 40X max. Buffer: 256 kBytes Emergency Eject: Pin-hole on front panel to release tray. Software Ejection/ Loading and Volume Control Form Factor: 5.25" half height.
Compatibility: DVD-ROM (single-layered and dual-layered), DVD-R 3.95GB & 4.7GB, DVD+R, DVD-RW (rev 1.0 & 1.1), DVD+RW, DVD-RAM 2.6GB & 4.7 GB, CD-ROM Mode1 and Mode2 data disc, CD-R,CD-RW,CD-ROM XA, CD-I, Photo-CD Multi-session, CD-Extra, CD TEXT, CD Audio disc, Mixed mode CDROM disc. Transfer rate (max): - CD-ROM: 6000Kbytes/s - DVD-ROM: 22.1 Mbytes/s CD-ROM ATA Interface (burst): - 16.6 Mbytes/s (PIO Mode 4/ MULTI word DMA Mode 2) - 8.3 Mbytes/s (Single word DMA Mode 2) - 66.7 Mbytes/s (Ultra DMA Mode 4) Rotation Speed: - CD-ROM: 8780 rpm - DVD-ROM: 9420 rpm Full Stroke: - CD-ROM: 160 ms - DVD-ROM: 180 ms Environmental Specifications: Table 6: DVD-ROM Drive Environmental Specifications
Operating
Temperature Humidity (% relative humidity) Vibration 5C to 45C 15% to 85% 0.25 G (zero to peak)
Non-operation
-40C to +60C 10% to 90% 50 G (zero to peak)
31
User Guide
www.nec-computers.com
Writing Speed
48x 48x
Non-operation
-30C to +60C 15% to 95% 2.0 G (5-500 Hz)
32
User Guide
www.nec-computers.com
Read
DVD-ROM Single Layer 6.6-16x CAV 9-22 Mbytes/sec Dual Layer 3-7x CAV 4.1-10 Mbytes/sec DVD-R/+R 6.6-16x CAV 9-22 Mbytes/sec DVD+R-DL 2-5x CAV 2.7-6.9 Mbytes/sec DVD+RW/-RW 3.3-8x CAV 4.5-11 Mbytes/sec DVD-Video with CSS protection 2-5x CAV 2.7-6.9 Mbytes/sec CD-ROM/CD-R Mode 1 and Mode 2 Form 1 (2048 Bytes) 20-48x CAV 3000 - 7200 kBytes/sec CD-RW Mode 1 and Mode 2 Form 1 (2048 Bytes) 13-32x CAV 1950 - 4800 kBytes/sec
33
User Guide
www.nec-computers.com
Read
DAE 13-32x CAV 1950 - 4800 kBytes/sec
34
User Guide
www.nec-computers.com
35
User Guide
www.nec-computers.com
36
User Guide
www.nec-computers.com
37
User Guide
www.nec-computers.com
38
User Guide
www.nec-computers.com
39
User Guide
www.nec-computers.com
40
User Guide
www.nec-computers.com
41
User Guide
www.nec-computers.com
42
User Guide
www.nec-computers.com
Caution
You may use either S-ATA or SCSI hard disk drives. However, mixing S-ATA and SCSI hard disk drives is not supported.
43
User Guide
www.nec-computers.com
Caution
You may use either S-ATA or SCSI hard disk drives. However, mixing S-ATA and SCSI hard disk drives is not supported.
44
User Guide
www.nec-computers.com
45
User Guide
www.nec-computers.com
Specifications
Graphics Processing Unit Full 128-bit floating-point precision pipeline
46
User Guide
www.nec-computers.com
12-bit subpixel precision 8 pixels per clock rendering engine Hardware accelerated antialiased points and lines Hardware OpenGL overlay planes Hardware accelerated two-sided lighting Hardware accelerated clipping planes 3rd-generation occlusion culling 16 textures per pixel Hardware-Accelerated Pixel Read-Back Next Generation Shading Architecture Fully programmable GPU (OpenGL 1.5/DirectX 9.0 class) Long fragment and vertex programs (up to 65,536 instructions) Looping and subroutines (up to 256 loops per vertex program) Dynamic flow control Conditional execution High-Level Shader Languages Optimized compilers for Cg, OpenGL shading language, and Microsoft HLSL OpenGL 1.5 and DirectX 9.0 support Open source compiler Architecture x16 PCI-Express 128MB high-speed DDR frame buffer 128-bit IEEE floating-point precision graphics pipeline 128-bit color 32-bit floating point frame buffer 12-bit subpixel precision Memory High-speed memory (128MB GDDR3) Advanced lossless compression algorithms (color and Z data)
47
User Guide
www.nec-computers.com
48
User Guide
www.nec-computers.com
Specifications
Graphics Processing Unit Full 128-bit floating-point precision pipeline 12-bit subpixel precision 8 pixels per clock rendering engine Hardware accelerated antialiased points and lines Hardware OpenGL overlay planes Hardware accelerated two-sided lighting Hardware accelerated clipping planes 3rd-generation occlusion culling 16 textures per pixel OpenGL quad-buffered stereo (3-pin sync connector) Hardware-Accelerated Pixel Read-Back Architecture x16 PCI-Express 128MB high-speed DDR frame buffer 128-bit IEEE floating-point precision graphics pipeline 128-bit color 32-bit floating point frame buffer 12-bit subpixel precision Unlimited programmability 3D volumetric textures Single-system powerwall Shading Architecture Fully programmable GPU (OpenGL 1.5/DirectX 9.0 class) Long fragment and vertex programs (up to 65,536 instructions) Looping and subroutines (up to 256 loops per vertex program) Dynamic flow control Conditional execution High-resolution Anti-aliasing Up to 16x Full-Scene Anti-aliasing (FSAA)
49
User Guide
www.nec-computers.com
Up to 2048x1536 per display or 3840x2400 for single digital display 12-bit subpixel sampling precision enhances AA quality Rotated grid FSAA significantly increases color accuracy and visual quality for edges, while maintaining performance Memory High-speed memory (128MB GDDR3) Advanced lossless compression algorithms (color and Z data)
50
User Guide
www.nec-computers.com
51
User Guide
www.nec-computers.com
Hardware Accelerated Pixel Read-Back Greater than 1.0GB/sec pixel read-back performance delivers massive host throughput, more than 5x the performance of previous generation graphics systems. PCI Express Support Designed specifically to take advantage of the next-generation PCI Express bus architecture. This new bus doubles the bandwidth of AGP 8X delivering over 4 GB per second in both upstream and downstream data transfers. Unified Driver Architecture Provides easy installation and manageability through a single unified driver for large scale system deployment. The performance and power of the NVIDIA Quadro FX are built on a solid foundation of quality engineering.
Specifications
Graphics Processing Unit Full 128-bit floating-point precision pipeline 12-bit subpixel precision 8 pixels per clock rendering engine Hardware accelerated antialiased points and lines Hardware OpenGL overlay planes Hardware accelerated two-sided lighting Hardware accelerated clipping planes 3rd-generation occlusion culling 16 textures per pixel OpenGL quad-buffered stereo (3-pin sync connector) Hardware-Accelerated Pixel Read-Back Architecture x16 PCI-Express 256MB high-speed GDDR3 frame buffer 128-bit IEEE floating-point precision graphics pipeline 128-bit color 32-bit floating point frame buffer 12-bit subpixel precision Up to 16x FSAA Unlimited programmability
52
User Guide
www.nec-computers.com
3D volumetric textures Single-system powerwall Next Generation Shading Architecture Fully programmable GPU (OpenGL 1.5/DirectX 9.0 class) Long fragment and vertex programs (up to 65,536 instructions) Looping and subroutines (up to 256 loops per vertex program) Dynamic flow control Memory High-speed memory (256MB GDDR3) Advanced lossless compression algorithms (color and Z data)
53
User Guide
www.nec-computers.com
54
User Guide
www.nec-computers.com
55
User Guide
www.nec-computers.com
Sophisticated Array Monitoring Tools Web-based Promise Array Management (WebPAM) software offers professional management tools in a simple-to-use, straightforward format. Array configurations, management and monitoring features are available via the web based interface. Moreover, the FastTrak SX family supports industry standard SNMP so third party management application integration is simplified.
Specifications
Controller Specifications Four SATA ports at 1.5Gb/s (150 MB/sec) Supports up to 1.6 terabytes of storage per controller (with four 400GB drives) Dual controller support within a system Low profile form factor ideal for 1U/2U servers 32-Bit, 66 MHz PCI bus; PCI 2.2 compliant Promise RAID Processor with integrated XOR engine for RAID parity calculations and memory controller for local cache memory 64MB onboard ECC cache memory FRAM for RAID5 transaction log to avoid data corruption in the event of application hangs Built-in GPIO ports for enclosure management RAID Levels Supported RAID 5: Striped parity on 3-4 drives, ultimate data protection, capacity and performance balance RAID 10: Data mirrored then striped across four drives, for double drive failure protection RAID 1: Mirrored pairs of drives for data protection with increased read performance RAID 0: Data striped across 2-4 drives for increased performance but no data protection JBOD: Just a Bunch Of Drives: independent connected drives with no RAID interconnection RAID Fault Tolerance and Robustness Features Multiple logical drive support enables combining different RAID levels on one set of disks Online array expansion and RAID level migration to add capacity as needed PerfectRAID technology for error handling and recovery of fatal media and disk errors
56
User Guide
www.nec-computers.com
Read Check table to avoid data read errors Support hot swap of failed drives and hot spare Automatic/manual rebuild of hot spare drive Background initialization for instant drive availability Background rebuild, migration and synchronization Error and event logging Variable stripe block size support to meet various application requirements Optimal disk utilization with gigabyte rounding Support for SMART capable drives Synchronization can be scheduled periodically for RAID array data consistency Advanced Performance Features Multiple caching policy support: Write-back: - Write-back cache for maximum write performance - Write-through: Write-through cache for data protection in the event of application freeze - Read ahead: Predictive read ahead caching based on application and data types Packet commands and interrupt coalescing minimize interrupts for better performance Elevator seek streamlines commands based on where data is located on the disk Load balancing (mirrored RAID array only) - Web-Based Promise Array Management Creates, deletes, expands, and converts disk arrays remotely Array synchronization and rebuild scheduling Monitors drive, array, and enclosure status and provides online event logging E-mail notification of disk, array, controller or enclosure events (e.g. error or degrade conditions)
57
User Guide
www.nec-computers.com
Highlights
160 MByte/sec performance SpeedFlex technology ensures top performance of all connected devices, regardless of SCSI generation Seamless backwards compatibility protects legacy devices Industry-leading compatibility, reliability* CRC (Cyclical Redundancy Checking) improves data integrity Domain Validation intelligently verifies system configuration for improved reliability
Specifications
1-channel, 64-bit (32-bit compatible), ideal for internal and external hard disk drive configurations Data Transfer Rate: 160MB/sec External Connectors - One 68-pin for LVD SCSI devices Internal Connectors - One 68-pin for LVD SCSI - One 68-pin for Ultra Wide SCSI - One 50-pin for Ultra SCSI Bus Type 64-bit PCI (32-bit compatible) Board Dimensions 6.87" x 3.87"
58
User Guide
www.nec-computers.com
Specifications
Hardware Features - 64-bit/ 133 MHz PCI/PCI-X interface - Compatible with 32-bit PCI slots (thus running in the slower 32-bit mode) - Single-channel Ultra320 SCSI card. Connectors - 68-pin internal connector - 68-pin VHDCI external connector for Ultra320 SCSI (LVD) hard disks drives Physical Specifications - Size: 16,8cm x 6,4cm
59
User Guide
www.nec-computers.com
Features
Disk Array Features - Supports RAID0/RAID1/RAID5/RAID10/RAID50 - Supports up to 40 logical drives - Supports hot-swap of failed drives - Automatic rebuild of hot spare drives - Auto resume on array reconstruction Harware Features - 64-bit / 66MHz PCI interface compliant to PCI Rev2.2 - A 64MB cache memory is soldered on the card.
60
User Guide
www.nec-computers.com
- Single-channel, PCI RAID controller card with an Ultra 320 SCSI interface - Modes supported: SE or LVD mode, SCSI FAST, ULTRA, ULTRA2, 160M and 320M Connectors: - one internal 68-pin - one external VHDCI-68-pin connector Physical & Environmental Specifications - Size: 16,76 x 6,45 cm - Operating temperature: up to 55C - Voltage: 5V 0.25V
61
User Guide
www.nec-computers.com
Setup Flow.
Selecting the server site Select a suitable site for the server. Assemble the 19-inch rack assembly.
Unpacking the system Unpack the server and accessories from the shipping carton box.
Installing the server Install the server into the rack assembly.
Connecting the power cord Connect the power cord to the server.
Turning on the server Power on the server to start software setups. Setups depend on the optional internal devices installed and the peripheral devices connected.
Installing the utilities Install the utilities in the provided EXPRESSBUILDER CD-ROM.
Making backup copies of system information After all the system setup procedures are completed, make backup copies of system information. System information is required for recovering the server from the trouble or after replacing the system board.
62
User Guide
www.nec-computers.com
Warning
Observe the following instructions to use the server safely. Failure to follow these instructions may result in death or serious personal injury. See General Safety Information on page 111 for details.
Do not use the server in any unapproved place. Do not connect the ground line to a gas pipe.
Caution
Observe the following instructions to use the server safely. Failure to follow these instructions may cause a fire, personal injury, or property damage. See General Safety Information on page 111 for details.
Do not carry or install the server only by a single person. Do not install the server where the load may be concentrated on a specific point.
Do not pull out a device from the rack if the rack is unstable. Do not leave more than one device being pulled out from the
rack.
Do not provide the wiring exceeding the rating power. Do not install the rack in the places listed below. Installing the rack or mounting the server on the rack in such a place may cause some malfunction to occur. Narrow space from which devices cannot be pulled out from the rack completely Place that cannot bear the total weights of the rack and devices mounted on the rack Place where stabilizers cannot be installed or where the rack can be installed only after the practice of proper earthquake-resistant construction Place of uneven or slanting floor Place of drastic temperature change (near a heater, air conditioner, or refrigerator)
63
User Guide
www.nec-computers.com
Place where intense vibration may be generated Place where corrosive gas is generated, chemicals are nearby, or chemicals may be accidentally sprayed over Place where a carpet not subject to anti-static process is laid. Place where some objects may be fallen on the rack Place near a device generating intense magnetic field (such as a TV, radio, broadcast/communication antenna, power transmission wire, and electromagnetic crane) is placed (If unavoidable, contact your sales agent to request proper shield construction.) Place where the power cord of the server must be connected to an AC outlet that shares the outlet of another device with large power consumption. Place near equipment that generates power noise (e.g., contact spark at power-on/ power-off of commercial power supply through a relay). If you must install the server close to such equipment, request your sales agent for separate power cabling or noise filter installation.
64
User Guide
www.nec-computers.com
65
User Guide
www.nec-computers.com
3. If parts are missing or the hardware is damaged, notify your server representative.
66
User Guide
www.nec-computers.com
Warning
Be sure that power to the system is turned off and unplugged. All voltage is removed only when the power cords are unplugged.
Avoid excessive vibration and shock. Dropping an electronic component can cause serious damage. Do not disconnect or remove parts other than those specified in the procedure. Do not touch I/O connector pins. All screws are Phillips-head, unless otherwise specified. On completion of any assembly or reassembly, perform a power-on test. If a fault occurs, verify that the assembly or reassembly was performed correctly. If the problem persists, see Solving Problems on page 199.
Static Precautions
An electrostatic discharge (ESD) can damage disk drives, option boards, and other components. You can provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground when handling system components. Electronic devices can be easily damaged by static electricity. To prevent damage, keep them in their protective packaging when they are not installed in your system.
Assembly
The following subsection describes how to assemble your rack-mount server into a standard 19-inch rack cabinet. Before you begin select an appropriate location in your rack cabinet for the rack-mount server. To improve rack stability, mount heavier items towards the bottom of the rack cabinet. If the rack is a stand-alone unit and the rack is more than 75% filled with components, consider installing an optional stabilizer kit.
Note: When planning your system configuration for the rack cabinet you should consider the length of the cables that interconnect system components.
67
User Guide
www.nec-computers.com
Warning
ANCHOR THE EQUIPMENT RACK: The equipment rack must be
anchored to an unmovable support to prevent it from falling over when one or more servers are extended in front of it on slide assemblies. The anchors must be able to withstand a force of up to 113 kg (250 lbs). You must also consider the weight of any other device installed in the rack.
MAIN AC POWER DISCONNECT: You are responsible for installing an AC power disconnect for the entire rack unit. This main disconnect must be readily accessible, and it must be labeled as controlling power to the entire unit, not just to the server(s).
GROUNDING
To avoid the potential for an electrical shock hazard, you must include a third wire safety grounding conductor with the rack installation. If a server power cord is plugged into an AC outlet that is part of the rack, then you must provide proper grounding for the rack itself. If server power cords are plugged into wall AC outlets, the safety grounding conductor in each power cord provides proper grounding only for the server. You must provide additional, proper grounding for the rack and other devices installed in it.
Caution
Temperature: The operating temperature of the server, when installed in an equipment rack, must not go below 5 C or rise above 35 C. Extreme fluctuations in temperature can cause a variety of problems in your server. Ventilation: The equipment rack must provide sufficient airflow to the front of the server to maintain proper cooling. It must also include ventilation sufficient to exhaust a maximum of 4,100 Btu's per hour for the server. The rack selected and the ventilation provided must be suitable to the environment in which the server will be used.
Note: For vertical reference, every three screw holes on the rack vertical mounting rail are equal to 1U (1.75 inches).
Mounting holes in the vertical rails of equipment racks are commonly spaced in a 5/8 x 5/8 x 1/2-inch sequence. Perform the following steps carefully; brackets must be mounted with precision to allow room for the next server you install in a rack.
68
User Guide
www.nec-computers.com
3. Insert two caged nuts (F in figure 2) as shown in figure 2. One in the hole just above the support rail, the other one eight holes above. Insert the caged nuts in the front mounting rail as follows (see figure 3): Position the caged nut on the inside of the front vertical mounting rails. Hook the side lip of a caged nut into the square hole in the rail.
69
User Guide
www.nec-computers.com
Push the other side lip of the caged nut into the square hole in the rail until it is secured. Repeat for each caged nut.
Warning
The handles are only used to slide the server in and out of the rack. DO NOT use these handles to carry the server.
Attach the handles (A in figure 1) to the rack mounting frame with two screws (B in figure 1).
70
User Guide
www.nec-computers.com
3. Install the rack mounting frame (A) on the server (B) as shown in figure 4 below.
4. Slide the rack mounting frame on the server until the front of the server protrude a little from the frame. 5. Replace the front panel. 6. Replace the right side door. 7. Align the rack mounting frame (A in figure 5) with the rear of the front panel (B in figure 5). 8. Secure the frame with the grubscrews (C in figure 5, four on each side) using the hex key (C in figure 1), enough to fix the frame to the server but not too much to prevent damage to the server case.
71
User Guide
www.nec-computers.com
Warning
The system can weigh up to 17.5 kg. If it contains numerous optional boards and peripheral devices, it will weigh more. To avoid personal injury, make sure you have at least one person help you lift or move the system. Do not use the handles of the rack mounting frame to lift the server.
1. Lift the sever onto the support rails and slide it toward the rear of the cabinet. 2. Secure the server to the vertical mounting rails with the four thumbscrews (A in figure 6).
72
User Guide
www.nec-computers.com
Making Connections
Connect your keyboard, monitor, and mouse. Also connect any external peripheral devices such as a printer or scanner by following the instructions included with these devices.
Caution
Damage to the system may result if the keyboard/ mouse cable is inserted or removed when power is applied to the system. Inserting a telephone line connector into a LAN RJ-45 port may result in personal injury and equipment damage.
73
User Guide
www.nec-computers.com
! WARNING
A power cord is provided for the power supply shipped with your system. Do not attempt to modify or use the supplied AC power cord if it is not the exact type required.
74
User Guide
www.nec-computers.com
75
User Guide
www.nec-computers.com
Power on your system as follows. 1. Make sure all external devices, such as a video display, keyboard, and mouse (optional) have been connected, and the power cords are connected. 2. Power on the video display and any other external devices. Note: If the system power cord(s) is connected to a power control unit such as an UPS (Uninterruptible Power Supply) make sure that the power control unit is powered on.
3. If applicable, open the door behind which the power button is located. 4. Press the POWER button to power on the system. The POWER lamp lights green. If it is does not light, make sure that the ac power cord is connected to a functional ac power source. After a few seconds your system begins the internal Power-On Self Tests (POST). The POST automatically checks the system board, CPU(s), memory, keyboard, mouse, and most installed peripheral devices. It also displays the start messages of the BIOS setup utility during execution. The POST check results should be especially monitored in the following cases: When the system is being used for the first time. When the system appears to fail. When the system beeps many times between power-on and the OS start-up. When an error message appears on the screen. Note: For error messages that appear on the display unit, see Error Messages on page 228.
76
User Guide
www.nec-computers.com
Caution
Always allow the POST to complete before powering down your system.
If you have problems powering on your system, see Solving Problems on page 199. After you have successfully powered on your system, insert the EXPRESSBUILDER CD-ROM into the CD-ROM device, reboot the system and follow the screen prompts to run EXPRESSBUILDER.
77
User Guide
www.nec-computers.com
78
User Guide
www.nec-computers.com
79
User Guide
www.nec-computers.com
Caution
Resetting the system clears the DIMM memory and the data in process. To reset the system when it is not frozen, make sure that no processing is in progress.
Hard reset Press the power switch at the front of the system. (See Forcing a Power Shutdown on page 79.) Soft reset If the system halts before starting the OS, press and hold Ctrl and Alt and press Delete. This restarts the system.
80
User Guide
www.nec-computers.com
81
User Guide
www.nec-computers.com
Configuring RAID
RAID Configuration Utility
The RAID (Redundant Array of Inexpensive Devices) option available for your system is either a RAID controller board, a RAID chipset on the motherboard, or both (depending on your configuration) which gives your system the added security of fault tolerance. If you want to change the RAID level or add additional hard disk drives to the array, use the RAID configuration utility. The RAID configuration utility is included with the RAID controller. If you are adding the RAID controller to an existing system, the RAID configuration utility allows you to configure your disk array before reinstalling your network operating system. The RAID controllers support various versions of RAID technology (referred to as RAID levels). To use any RAID level, you must configure the RAID controller using the RAID configuration utility prior to installing your Network Operating System. For an explanation of this utility, check this users guide for basic informations, and refer to the documentation that comes with the RAID controller (the manufacturers documentation is generally included on the EXPRESSBUILDER CD-ROM). It describes RAID technology and provides tips on making your array perform well in your specific application. It also covers array hardware preparation, configuration, and initialization. After completing the steps in the manual, you can install your Network Operating System.
82
User Guide
www.nec-computers.com
RAID Levels
RAID Configuration RAID 0 RAID 1 RAID 10 RAID 5 RAID 0 and RAID 1 RAID0 (striping) When a logical drive is striped, the read and write blocks of data are interleaved between the sectors of multiple disk drives. Performance is increased, since the workload is balanced between drives or members that form the logical drive. Identical drives are recommended for performance as well as data storage efficiency. The logical drive's data capacity is equal to the number of drive members multiplied by the smallest logical drive member's capacity. Figure 1. RAID 0 Stripe interleaves data across multiple drives For example, one 100GB and three 120GB drives will form a 400GB (4 x 100GB) logical drive instead of 460 GB. Number of required hard disk drives 2 2 4 3
Warning
RAID0 does not have data redundancy. When a hard disk
drive failure occurs, data cannot be restored.
Logical capacity of the array becomes a multiple of the connected hard disk drive.
RAID1 (mirroring) When a logical drive is mirrored, identical data is written to a pair of disk drives, while reads are performed in parallel. The reads are performed using elevator seek and load balancing techniques where the workload is distributed in the most efficient manner. Whichever drive is not busy and is positioned closer to the data will be accessed first. With RAID 1, if one disk drive fails or has errors, the other mirrored disk drive continues to function. This is called Fault Tolerance. Moreover, if a spare disk drive is present, the spare drive will be used as the replacement drive and data will
begin to be mirored to it from the remaining good drive.
Due to the data redundancy of mirroring, the capacity of the logical drive is only the size of the smallest disk drive. For example, two 100GB disk drives which have a combined capacity of 200GB instead would have 100GB of usable storage
83
User Guide
www.nec-computers.com
when set up in a mirrored logical drive. Similar to RAID 0 striping, if disk drives of different capacities are used, there will also be unused capacity on the larger drive.
Warning
RAID1 reads or writes data to/from the several hard disk
drives at the same time. The disk access performance is lower than the single disk.
Raid 10 & RAID 5 These RAID levels may also be available on your server. Browse through the next sections of this Users Guide for more information. RAID 10 Mirror/Stripe combines both of the RAID 0 and RAID 1 logical drive types. It can increase performance by reading and writing data in parallel while protecting data with duplication. At least four disk drives are needed for RAID 10 to be installed. With a four-disk-drive logical drive, one drive pair is mirrored together then striped over a second drive pair. The data capacity is similar to a RAID 1 logical drive, with half of the total storage capacity dedicated for redundancy. An added plus for using RAID 10 is that, in many situations, such a logical drive offers double fault tolerance. Double fault tolerance may allow your logical drive to continue to operate depending on which two disk drives fail.
84
User Guide
www.nec-computers.com
RAID 5 RAID level 5 organizes data across the disk drives of the logical drive, and distributes parity information across the disk drives along with the data blocks. This organization allows increased performance by accessing multiple disk drives simultaneously for each operation, as well as fault tolerance by providing parity data. In the event of a disk drive failure, data can be re-calculated by the RAID system based on the remaining data and the parity information. The adjustable block size of the RAID 5 logical drive allows for performance tuning based on the typical I/O request sizes for your system. The block size must be set at the time the logical drive is created and cannot be adjusted dynamically. RAID 5 makes efficient use of hard drives and is the most versatile RAID Level. It works well for file, database, application and web servers. The capacity of a RAID 5 logical drive is the smallest disk drive size multiplied by the number of disk drives, less one. Hence, a RAID 5 logical drive with four 100 GB disk drives will have a capacity of 300 GB. A logical drive with two 120 GB disk drives and one 100 GB disk drive will have a capacity of 200 GB.
85
User Guide
www.nec-computers.com
86
User Guide
www.nec-computers.com
87
User Guide
www.nec-computers.com
88
User Guide
www.nec-computers.com
5. Press the arrow keys to move to Disk Assignments. Press the spacebar to toggle between N and Y for each available drive. Y means this disk drive will be assigned to the logical drive. Assign the appropriate number of disk drives to your logical drive. A disk drive that is not assigned to a logical drive will automatically function as a Hot Spare Drive. 6. Press Ctrl-Y to save your logical drive configuration. You have the option of using all of the disk drive capacity for one logical drive or allocating a portion to a second logical drive. 7. Choose one of the following: Use the full capacity of the disk drives for a single logical drive. See One Logical Drive on page 89. Split the disk drives among two logical drives. This option does not apply to JBOD. See Two Logical Drives on page 89. One Logical Drive 1. Press any key (except for Ctrl-Y) to use the full portion of the logical drive for one logical drive. 2. Press Esc to exit to the Main Menu. Press Esc again to exit the Utility. 3. Press Y to restart the computer. You have successfully created a new RAID logical drive. You must partition and format your new logical drive before you can use it. Use the same method of partitioning and formatting a logical drive as you would any other fixed disk added to your computer system. Two Logical Drives 1. Press Ctrl-Y to allocate a portion of the disk drives to the first logical drive. 2. Enter the desired capacity in MB for the first logical drive and press Enter. The Define LD Menu displays again. Press the up and down arrow keys to select an available logical drive number and press Enter. 3. Choose the RAID level and options for the second logical drive. 4. Press Ctrl-Y to save your logical drive configuration. 5. Press Esc to exit to the Main Menu. Press Esc again to exit the Utility. 6. Press Y to restart the computer. You have successfully created a new RAID logical drive. You must partition and format your new logical drive before you can use it. Use the same method of partitioning and formatting a logical drive as you would any other fixed disk added to your computer system. View Drive Assignments, Split Disk Drives After you create two logical drives from the same set of disk drives, press 1 on the Main Menu screen to see the View Drive Assignments screen.
89
User Guide
www.nec-computers.com
Note that the combined size of the extents is slightly smaller than the total capacity of the disk drive. Unassigned drives are labeled free and are considered hot spares to provide fault tolerance in the event of a disk drive failure. Alternatively, you can use an unassigned drive to create a new logical drive.
Controller Configuration
From the Main Menu screen, press 4 to display the Controller Configuration Options screen. The Controller Configuration Options screen has one setting and provides diagnostic information. Halt On Error The Halt On Error function causes the FastTrak controller to stop the boot process at the FastTrak BIOS screen when there is a problem with your logical drive. For example, a disk drive failure causes your logical drive to go critical. Depending on the Halt On Error setting, one of the following events will happen: Enabled Your system will stop booting at this point to alert you to the condition. Press Ctrl-F to enter the FastBuild utility and diagnose the problem. Disabled Your system will continue booting. In this case, you could use WebPAM to diagnose the problem. System Resources The information in the System Resources section might be helpful for troubleshooting purposes: Installed memory address and size The system IRQ used by the FastTrak card Base Addresses (advanced troubleshooting)
90
User Guide
www.nec-computers.com
Note: Please refer to the FastBuild online documentation for more information.
91
User Guide
www.nec-computers.com
92
User Guide
www.nec-computers.com
6. 7.
8. 9. 10.
usage. The default selection is 128 KB for RAID 0 and RAID 10 volumes, and 64KB for RAID 5 volumes. Press Enter to select the physical disks. This will bring up another dialog. Select the appropriate number of hard drives by scrolling through the list of available hard drives by using the arrows keys and pressing Space to select the drive. When you have finished selecting hard drives, press Enter. Select the volume size. At the Create Volume prompt, press Enter to create the volume. Confirm this selection by pressing Enter after the prompt. Scroll to option 4 Exit and press Enter to exit the RAID Configuration utility. Confirm the exit by pressing Y.
Note: To change any of the information before the volume creation has been confirmed, you must exit the Create Volume process and restart it. Press Esc to exit the Create Volume process.
Warning
All data on the RAID drives will be lost unless the volume that is selected is a RAID 1 volume.
1. Select option 2 Delete RAID Volume and press Enter to delete the RAID volume. 2. Use the up and down arrow keys to select the volume you would like to delete. 3. Press Delete to delete the RAID volume. Confirm the volume deletion by pressing Y.
93
User Guide
www.nec-computers.com
Warning
All data on the RAID drives and any internal RAID structures will be lost unless the drives are members of a RAID 1 volume. Resetting drives that are members of a RAID 1 volume to nonRAID will not result in the loss of data on those member drives.
1. Select option 3 Reset Disks to Non-RAID and press Enter to delete the RAID set and remove any RAID structures from the drives. 2. In the selection screen, use Space to select the drives you would like to reset. Press Enter after selecting the drives. 3. Confirm the selection by pressing Y.
94
User Guide
www.nec-computers.com
Caution
Use two hard disk drives of the same revolution (rpm). To configure RAID 1, use also two hard disk drives of the
same capacity.
Note: The factory-set value is to use the hard disk drive as a single disk drive.
To configure a disk drive connected to the onboard SCSI connector with the SCSISelect Utility: 1. Start the SCSISelect Utility. See Running the SCSISelect Utility on page 172.
AIC-7902 A at Slot 23 02:03:00 AIC-7902 B at Slot 23 02:03:01
95
User Guide
www.nec-computers.com
2. Select the channel to set HostRAID to open the Options window. 3. Select [Configure/View SCSI Controller Settings] and press Enter.
5. Change it to [Enabled].
6. Press Esc. The confirmation message [Save Changes Mode?] appears. Select [Yes].
96
User Guide
www.nec-computers.com
Main Menu When you select [Configure/View HostRAID Settings], the Main Menu as shown below appears upon completion of the device scan.
97
User Guide
www.nec-computers.com
ID Type
Indicates either the SCSI ID of the hard disk drive or the ID of the array. Indicates the RAID level for the array, and any available disk drive that is not in the array. - Hard Drive: Available hard disk drive that is not in the array. - Striped (R0): Array configured in RAID0. - Mirrored (R1): Array configured in RAID1. - Stripe/Mirror (R10): Array configured in RAID 10 (spanning of RAID1). - Spare: Hard disk drive assigned as a spare disk.
Indicates the manufacturer of the hard disk drive or HostRAID (Adaptec). Indicates the model name of the hard disk drive or the array name. Indicates the capacity of the hard disk drive or that of the array. Indicates the status of the hard disk drive or array. - Free: Available hard disk drive that is not in the array. - Optimal: Array is in normal state. - Degraded: One of the RAID1 or RAID10 hard disk drives is failed. - Dead: One or more RAID0 hard disk drives is failed. Two or more RAID1 or RAID10 hard disk drives are failed. - Building: The array is in build process. - Verify: The array is in verify process. - Rebuild: The array is in rebuild process.
98
User Guide
www.nec-computers.com
When you select the array on Main Menu, the detailed information of the hard disk drives in array is displayed.
Detailed indications
ID Type
Indicates the SCSI ID of the hard disk drives that configures the array Indicates the RAID level for the array. - Striped (R0): Array configured in RAID0 - Mirrored (R1): Array configured in RAID1 - Stripe/Mirror (R10): Array configured in RAID 10 (spanning of RAID1)
Indicates either the manufacturer of the hard disk drive or HostRAID (Adaptec). Indicates the model name of the hard disk drive or the array name. Indicates the capacity of the hard disk drive or that of the array. Indicates the status of the hard disk drive or that of the array. - Optimal: the hard disk drive is operating normally. - Degraded: the hard disk drive is degraded. - Failed: the hard disk drive is failed. - Building: the hard disk drive is being built. - Verify: the hard disk drive is being verified. - Replaced: the hard disk drive is being rebuilt. - Missing: the hard disk drive is hidden from the controller.
Exiting the Utility To exit the utility, press Esc until a message prompts you to exit.
99
User Guide
www.nec-computers.com
Select [Yes] to exit and press any key to restart the computer. The changes you have made become valid after the system restarts.
Creating Arrays
Follow the procedures below to create an array. Requirements Before creating arrays, make sure the disks for the array are connected and installed in your system. 1. Start the SCSISelectUtility. Select [Configure/Veiw HostRAIDSettings] from Options menu of the channel to create an array.
Note: Some characters may not be displayed correctly when the console redirection is used. It is safe to bypass this issue.
Caution
At least two hard disk drives are required to create an array. If hard disk drives of different capacities are used, the array
capacity is determined according to the smaller one.
100
User Guide
www.nec-computers.com
3. Select a RAID type in [Select RAID Type] window and press Enter. Put a cursor to the selected item, another window opens indicating the minimum and maximum number of disks to create an array and a message for assigning a spare disk.
Note: To set the RAID level, see or Creating RAID1 Array on page 103 and Creating RAID0 Array on page 101.
Caution
After creating an array, set the boot priority for the created array according to "Boot Priority".
Creating RAID0 Array To create a RAID0 array: 1. Select [RAID-0] on the [Select RAID Type] window.
101
User Guide
www.nec-computers.com
2. Use the cursor key to highlight the desired hard disk drives, press Space to select them (an [X] mark is placed next to the selected hard disk drive) and when the selection is finished, press Enter to validate it.
. 3. Select the desired stripe size and press Enter. Available stripe sizes are 16, 32, and 64 KB. 4. Enter the desired RAID Name in [Assign RAID Name] window and press Enter.
Caution
A RAID Name must be unique, and up to 15 characters are
acceptable.
5. The message "Do you want to make this array as bootable?". Select either [YES] or [NO], and then press Enter.
Note: The boot priority can be changed after the arrays have been created. Refer to Boot Priority on page 109.
6. When prompted with the message [Create Array?], select [Yes] and press Enter. Selecting [No] cancels the array creation and returns to the Main menu.
102
User Guide
www.nec-computers.com
7. When prompted with the message [Are you sure?], select [Yes] and press Enter. Selecting [No] cancels the array creation and returns to the Main menu. 8. When the message [Build Completed] is displayed, press Esc to return to the Main menu.
Note: On the Main menu, make sure that "Optimal" is indicated for the status of the created array.
Creating RAID1 Array To create a RAID1 array, perform either of the followings: Create a new RAID1 array. Migrate to RAID1 array using the data stored in an existing single disk. (Migration) Creating RAID1 array using an existing single hard disk drive is called "migration". During the migration, the source hard disk drive must have been used as the boot disk in the standard SCSI connection. Refer to the "HostRAID Setup Card" documentation for details on the migration.
To create a RAID1 array:
2. Use the cursor key to highlight the desired hard disk drives, press Space to select them (an [X] mark is placed next to the selected hard disk drive) and when the selection is finished, press Enter to validate it.
Select one of the options in the [RAID-1 Build Option] window and press Enter.
103
User Guide
www.nec-computers.com
- Create new RAID-1:Default - Copy from (X) to (Y):Copy data from the disk of ID X to that of ID Y. - Copy from (Y) to (X):Copy data from the disk of ID Y to that of ID X.
Caution
Double-check the copy source and copy destination. If they are incorrect, the data will no longer be restored.
3. Enter the desired RAID Name in [Assign RAID Name] window and press Enter.
Caution
A RAID Name must be unique, and up to 15 characters are
acceptable.
4. The message "Do you want to make this array as bootable?". Select either [YES] or [NO], and then press Enter.
Note: The boot priority can be changed after the arrays have been created. Refer to Boot Priority on page 109.
5. When prompted with the message [Create Array?], select [Yes] and press Enter. Selecting [No] cancels the array creation and returns to the Main menu. 6. When prompted with the message [Are you sure?], select [Yes] and press Enter. Selecting [No] cancels the array creation and returns to the Main menu.
104
User Guide
www.nec-computers.com
Caution
Be sure to complete the Build process. Do not stop the process by pressing Esc. The OS only detects arrays which have been completly built, and their status set to "Optimal". In addition, no OS can be installed in that array.
7. When the message [Build Completed] is displayed, press Esc to return to the Main menu.
Note: On the Main menu, make sure that "Optimal" is indicated for the status of the created array.
Creating RAID10 Array 1. Select [RAID-10] on [Select RAID Type] window and press Enter.
2. Use the cursor key to highlight the desired hard disk drives, press Space to select them (an [X] mark is placed next to the selected hard disk drive) and when the selection is finished, press Enter to validate it.
105
User Guide
www.nec-computers.com
3. Select the desired stripe size and press Enter. Available stripe sizes are 16, 32, and 64 KB. 4. Enter the desired RAID Name in [Assign RAID Name] window and press Enter.
Caution
A RAID Name must be unique, and up to 15 characters are
acceptable.
5. The message "Do you want to make this array as bootable?". Select either [YES] or [NO], and then press Enter.
Note: The boot priority can be changed after the arrays have been created. Refer to Boot Priority on page 109.
6. When prompted with the message [Create Array?], select [Yes] and press Enter. Selecting [No] cancels the array creation and returns to the Main menu. 7. When prompted with the message [Are you sure?], select [Yes] and press Enter. Selecting [No] cancels the array creation and returns to the Main menu. 8. When the message [Build Completed] is displayed, press Esc to return to the Main menu. Deleting Arrays
To delete an array:
Caution
Before deleting an array, back up the hard disk drive data. Deleted arrays cannot be restored.
1. On the main menu, highlight the array you wish to delete and press Enter.
106
User Guide
www.nec-computers.com
3. Select [Yes] when prompted with the message [Delete Array?] and press Enter. Selecting [No] returns to the main menu without deleting any array. 4. Depending on your RAID level: <RAID0> The [Deleting information] window appears, select the hard disk drive from which you wish to delete a partition or boot block, or select [None], then press Enter. <Example> Drive ID 0:Data in drive 0 is entirely erased. Data in drive 1 is reserved. Drive ID 1:Data in drive 1 is entirely erased. Data in drive 0 is reserved. Drive ID 0 & 1:All the data in both drives is erased. None:Array is deleted, but the data is reserved in both drives. <Other than RAID0> The [Deleting information] window is not displayed, proceed to the next step.
107
User Guide
www.nec-computers.com
Caution
The partition or boot block of the selected hard disk drive will be deleted.
5. Select [Yes] when prompted with the message [Are you sure?] and press Enter. Selecting [No] returns to the main menu without deleting any array. Creating Spare Disks Up to two spare disks can be assigned for one channel. Spare disk is available for RAID1 and RAID10 (spanning of RAID1) only.
Note: Spare disks must have a larger capacity than the hard disk drives configuring the array.
108
User Guide
www.nec-computers.com
3. Select the spare disk from the list of available disks, and press Enter. 4. Select [Yes] when prompted with the message [Are you sure?] and press Enter. Selecting [No] returns to the Main menu without assigning any spare disk. 5. On the Main menu, make sure that the type of the selected hard disk drive is set to "Spare", and its status "Optimal".
To unassign a spare disk, take the same steps from 1 to 4, using "Delete Spare" instead of "Add Spare". Boot Priority To specify boot priority to an array: 1. Select the desired array, and press Enter. 2. Press B on the window showing the array details.
Note: Some characters may not be displayed correctly when the console redirection is used. It is safe to bypass this issue.
109
User Guide
www.nec-computers.com
110
User Guide
www.nec-computers.com
Warning
The DC push-button on/off switch on the front panel does not turn off completely the system AC power. +5vdc is present on the system board whenever the AC power cord connects the system to an AC outlet. Before doing the procedures in this manual, make sure that your system is powered off and unplug the AC power cord from the back of the chassis. Failure to disconnect the power cord before opening your system can result in personal injury and equipment damage.
Caution
Operating your system with the top covers removed can damage your system components. For proper cooling and airflow, always replace the top covers before powering on your system.
Warning
Avoid burns: If the system has been running, any installed processor and heat sink on the processor board(s) will be hot. To avoid the possibility of a burn, be careful when removing or installing components that are located near processors.
Contact your sales representative or dealer for a list of approved optional peripheral devices.
111
User Guide
www.nec-computers.com
Static Precautions
An electrostatic discharge (ESD) can damage disk drives, option boards, and other components. You can sensure some ESD protection by wearing an antistatic wrist strap attached to chassis ground when handling system components. Electronic devices can be easily damaged by static electricity. To prevent damage, keep them in their protective packaging when they are not installed in your system.
Equipment Log
Use the equipment log form located at the end of this manual to record the model and serial number of your system, all the installed options, and any other pertinent information specific to your system. You will need this information when configuring your system.
112
User Guide
www.nec-computers.com
Note: If the system power cord is connected to a power control unit such as an UPS (Uninterruptible Power Supply), refer to the UPS user's guide for proper power-off procedures.
6. Unplug all the I/O cables connected to the rear panel of your system.
113
User Guide
www.nec-computers.com
4. Lift the release latch on the back of your system as shown in the picture below.
5. Carefully slide the right side door about two centimetres towards the back of the unit. Please note that you may find this procedure easier to follow if you lay the unit on the left side. 6. Lift the right side door away from the computer
114
User Guide
www.nec-computers.com
Note: If you have previously removed the front panel, be sure to fasten it securely to the chassis before restoring the cover. The front panel must be securely connected to the chassis before you replace the cover.
1. Take a few moments to examine the interior side of the cover, and notice the 2 rails on two separate edges and the 3 slots located on a third edge. 2. Leaving about 1 centimetre to slide the cover forward, lay the cover on the chassis, and check that the rail is ready to slide on its corresponding edge and that the slots are ready to fit with their corresponding metal hooks. You may find this procedure easier to follow if you lay the unit on the left side. 3. Slide the cover forward as far as it will go, and make sure the cover is properly inserted; the cover, the chassis and the front panel should fit squarely together. 4. Push the release latch down. 5. Lock the key.
115
User Guide
www.nec-computers.com
3. Once the left side is free, pivot the front panel toward you until it is totally released.
116
User Guide
www.nec-computers.com
5. Take two slide rails marked as CD-ROM. Slide rails come with the system in a plastic bag. 6. Attach the slide rails to the upper holes on both side of the 5.25-inch device.
7. Slide in the 5.25-inch device until it clicks into place. 8. Connect the data cable to the device with the marked edge toward pin 1 of the drive. See Cabling IDE Devices on page 138. 9. Connect the power cable to the drive. See Cabling IDE Devices on page 138. 10. Replace the front panel. See Replacing the Front Panel on page 116. 11. Replace the right side door. See Replacing the Right Side Door on page 115.
Note: Modify the BIOS Setup program to recognise the additional device. For additional information, refer to BIOS Setup Utility on page 238.
117
User Guide
www.nec-computers.com
118
User Guide
www.nec-computers.com
5. Slide in the floppy disk drive. 6. Connect the data cable to the floppy disk drive with the marked edge toward pin 1 of the drive. See Cabling IDE Devices on page 138. 7. Connect the power cable to the drive. See Cabling IDE Devices on page 138. 8. Replace the front panel. See Replacing the Front Panel on page 116. 9. Replace the right side door. See Removing the Right Side Door on page 114.
Note: Modify the BIOS Setup program to recognise the additional device. For additional information, refer to BIOS Setup Utility on page 238.
119
User Guide
www.nec-computers.com
4. Disconnect the data cable and the power cable from each installed hard disk drive.
Caution
Be careful when working around the cables connected to the already installed drives. If necessary disconnect these cables, but be sure to note which device each cable or power lead was attached to.
120
User Guide
www.nec-computers.com
5. Both holding the HDD bracket and pressing down the latch, gently slide the HDD bracket out of the chassis.
6. The hard disk drive is secured to the bracket with 3 screws located on both sides of the hard disk drive. Remove these screws, and slide the hard disk drive out of the bracket. 7. Set the hard disk drive aside.
Caution
Make sure to install hard disks starting from the upper slot.
1. Refer to the information provided with the hard disk drive for pre-installation instructions and master/slave/cable select pin configurations. See Preparing IDE Devices on page 145. 2. Remove the right side door. See Removing the Right Side Door on page 114. 3. If applicable, disconnect the data and power cables of the installed hard disk drives. 4. Loosen the screw (A) securing the HDD bracket and the 3.5/5.25-inch bracket together.
121
User Guide
www.nec-computers.com
Caution
Be careful when working around the cables connected to the already installed drives. If necessary disconnect these cables, but be sure to note which device each cable or power lead was attached to.
6. Notice the screw holes located on each side of the HDD bracket, and the corresponding screw holes located on the hard disk drive you mean to install. Making sure the screw holes will line up, slide the hard disk drive into one of the available slots, connectors last. 7. Secure screws into the three side screw holes of the hard disk drive. 8. Slide the HDD bracket into its original place. 9. Secure the screw loosened in step 5. 10. Connect the data and power cables to their respective hard disk drives. See Preparing IDE Devices on page 145. 11. Replace the right side door. See Replacing the Right Side Door on page 115.
Note: Modify the BIOS Setup program to automatically recognise the hard disk drive. For additional information, refer to BIOS Setup Utility on page 238.
122
User Guide
www.nec-computers.com
The two tabs that hold the cache actually break: this is normal.
6. Take four slide rails marked as CD-ROM. Slide rails come with the system in a plastic bag. 7. Attach two slide rails onto both sides of the hard disk drive cage as shown in the picture below.
8. Connect the cables getting out of the hard disk drive cage slot to the hard disk drive cage. See Cabling the SCSI Hard Disk Drive Cage on page 125.
123
User Guide
www.nec-computers.com
9. Slide in the hard disk drive cage until it clicks into place.
10. Replace the front panel. See Replacing the Front Panel on page 116. 11. Replace the right side door. See Replacing the Right Side Door on page 115.
Note: Modify the BIOS Setup program to recognise the additional device. For additional information, refer to BIOS Setup Utility on page 238.
5. Replace the front panel. See Replacing the Front Panel on page 116. 6. Replace the right side door. See Replacing the Right Side Door on page 115.
124
User Guide
www.nec-computers.com
125
User Guide
www.nec-computers.com
Upgrading Microprocessor
Your system is fitted with a processor installed in a socket LGA 775.
Removing a Processor
1. Remove the right side door. See Removing the Right Side Door on page 114. 1. Lay the server on its left side (this is not mandatory, but it will make the process easier to follow). 2. Disconnect the fan cable(s) from the processor fan connector(s) on the motherboard. 3. Remove the processor heatsink: - Remove the four screws fastening the heatsink to the motherboard. - Remove the heatsink manually using a gentle rocking motion.
Reset the fasteners caps to their original position. Re-attach the cable to the cable management clips. 4. Open the processor socket: - Use your right thumb to push down and outwards the lever in order to disengage it from the retention tab.
Caution
If you do not follow scrupulously these instructions, the lever can bounce back and cause bend contacts.
- Rotate the load lever to its fully open position at approximately 135. - Rotate the load lever to its fully open position at approximately 100. 5. Grasp the processor (use your index to hold the load plate side, and your thumb to hold the lever side). 6. Lift the processor straight and away. 7. Set the processor immediately in its protective cover. - Hold the CPU by three of its corners. - The chamber of the protective cover should match the connection 1 on the CPU. - The rentention tabs on the cover and the processor contacts should point each other.
126
User Guide
www.nec-computers.com
Installing a CPU
1. Remove the processor from its shipping materials, and, if applicable, remove its protective cover.
Caution
Do not touch the processor sensitive contacts. Hold the processor by the substrate edges. 2. Locate the connection 1 indicator and the two orientation key notches on the CPU and on the socket. 3. Grasp the processor with your thumb and index finger by the orientation key notches. 4. Carefully lower down the processor into the socket body.
Caution
Do not tilt the processor or shift it into place, doing so may damage the sensitive contacts.
5. Check that the orientation notches and the connection 1 indicator are properly fitted to the socket body. 6. Close the soket: - Close the load plate. - Press gently on the load plate and engage the load lever. - Secure the load lever under its retention tab. 7. Remove the heatsink from its packaging materials. 8. Place the heatsink on the processor socket. - Ensure that the fan cable(s) are on the closest side to the fan(s) header(s) on the motherboard. - Align the screws with the screwholes on the motherboard. - Make sure that the heatsink is completely level with the motherboard.
Caution
Check the following:
127
User Guide
www.nec-computers.com
The screws are perpendicular to the heatsink. 9. Secure the heatsink: - Hold the heatsink to prevent it from tilting, and tighten the screws. 10. Connect the fan cable(s) to the header(s) on the motherboard. 11. Secure the excess cable with a tie-wrap to ensure that the cable does not interfere with fan operation or make contact with other components. 12. Replace the right side door. See Replacing the Right Side Door on page 115.
128
User Guide
www.nec-computers.com
If your memory configuration requires the removal of a module, perform the following steps: 1. Remove the computer right side door. See Removing the Right Side Door on page 114. 2. Locate the memory upgrade sockets on the motherboard. 3. Press the plastic clips at the outer edge of the socket away from the memory module. This ejects the memory module from the socket. Do not touch the module's metal "fingers." Store the module in an anti-static bag (available at electronic supply stores) or a cardboard box. 4. IAlign the new module with an empty memory socket. Make sure the notch on the module aligns with the key in the socket. The module is designed to install into the socket in only one way. 5. Press the module firmly into the socket. If you have difficulty installing a module, do not force it! Carefully remove the module, then check the
129
User Guide
www.nec-computers.com
alignment of the module's notch with the one in the socket. Then re-install the module. 6. Make sure the locking clips at either end of the module click closed. If the brackets do not secure themselves to the module, carefully remove the module, then reinstall it. 7. Replace the computer right side door. See Replacing the Right Side Door on page 115.
Note: The amount of installed memory will be automatically detected by the system.
130
User Guide
www.nec-computers.com
Caution
Removing the battery from the motherboard causes the computer to lose system configuration information. Before removing it, run Setup and record the system configuration settings. Use this information to restore the system after replacing the battery.
1. Turn off and unplug the system unit and any external options connected to the system. 2. Remove the right side door. See Removing the Right Side Door on page 114. 3. Locate the battery on the motherboard. See Motherboard on page 22. 4. Note that the + side faces the circular-shaped cut-out. Pull on the battery to disengage it from the tabs.
Warning
The battery may explode if it is incorrectly replaced or improperly discarded. Use only an identically rated battery from the same manufacturer.
5. With the positive (+) side facing the circular cut-out (away from the tabs), press the new battery into the socket. 6. Replace the right side door. See Replacing the Right Side Door on page 115. 7. Connect the external peripherals and the power cables. 8. Run Setup to reconfigure system parameters.
131
User Guide
www.nec-computers.com
Specific Recommendations
RAID Controller Take the following into consideration when installing either a S-ATA Disk array controller or a SCSI Disk array controller. Refer to the manual that comes with the RAID controller for more details. Prepare the hard disk drives and cables corresponding to the RAID controller to be installed. Configure the Logical Settings of the hard disk drive. Prepare the number of hard disk drives required for the desired RAID (Redundant Array of Inexpensive [Independent] Disks) level. See Configuring RAID on page 83. Installing hard disks in the disk array configuration or changing the RAID level initializes hard disks. Make sure to backup any valuable data that may be present on the hard disk drive before installing the disk mirroring controller board and configuring the array. Use hard disks of the same capacity and revolution for each pack to configure them in the array. The disk array configuration improves the disk reliability. On the other hand, the disk capacity is reduced (not equal to the sum of the arrays hard disks total capacity). Use an appropriate RAID configuration utility to configure the RAID.
When the disk array controller board is replaced, restore the disk array configuration information to the new disk array controller board. Use the configuration utility for the restoration. Refer to the RAID configuration utlity specific to your card for more details.
132
User Guide
www.nec-computers.com
To indicate the global disk access status of drives connected to the RAID controller with the DISK ACCESS lamp on the front panel of the system (depending on your chassis), use the LED cable that comes with your system to connect the RAID controller to the hard disk drive cage.
A
Figure 27: LED Cable LED Cable end A goes to the hard disk drive cage. LED Cable end B goes to the RAID controller.
Two examples are shown below. Refer to the instructions that come with the card for more details.
A B
Figure 28: Disk Array Controller (S-ATA) A = Red pin B = Black pin
A B
133
User Guide
www.nec-computers.com
SCSI Controller Take the following into consideration either when installing an SCSI controller or when using SCSI hard disk drives as internal hard disk drives. Refer to the manual that comes with the SCSI controller for details. Prepare the hard disk drives (up to 4 drives) and cables appropriate to SCSI controller to be installed. Configure the Logical Settings of hard disk drive. When the controller is choosed to boot on OS, install the hard disk controller in the highest priority PCI slot, i.e. in the smallest PCI slot number. After the installation, set the transfer rate of the board, those of the devices connected to the board, and other parameters by using the SCSI BIOS utility of the SCSI controller. Refer to the document coming with the board for the details of the settings and the procedures. Two examples are shown below. Refer to the instructions that come with the card for more details.
A
134
User Guide
www.nec-computers.com
Figure 31: SCSI Controller for Disks A - External SCSI Connector B - Internal SCSI Connector C - Hard Disc Activity LED Connector (not used)
Graphics Card When installing 75W or greater add-in cards (especially graphics cards) in both the PCI-E x16 and x4 connectors, the add-in cards must be individually powered. Use either of the following solutions: Use available power cables from the server power supply and plug the connector onto the graphics cards. Plug the graphics cards onto a specific power connector on the motherboard. See Motherboard on page 22.
Caution
Failure to specifically power 75W or greater add-in cards may damage both the motherboard and the add-in cards.
135
User Guide
www.nec-computers.com
2. Locate the add-on card holder near the slot you mean to fit with an expansion card.
3. Pull up the relevant latch and slide it out. 4. Remove the expansion slot cover from the chassis and set it aside. Save the expansion slot cover in a safe place in case you ever need to replace it.
5. Remove your expansion card from its protective packaging. Do not touch the metal fingers on the edge of the card. 6. Check the expansion card's documentation for any switches or jumpers that may need to be set, and set them now. 7. Carefully, but firmly, press the expansion card into the connector. 8. Replace the computer right side door. See Replacing the Right Side Door on page 116.
136
User Guide
www.nec-computers.com
3. Pull up the relevant latch and slide it out. 4. Do not touch any components on the card - handle it only by its edges, to avoid risk of damage from electrostatic discharge. Without flexing the motherboard, carefully unplug the card from its connector on the motherboard, and remove it from the expansion slot on the chassis' rear panel. 5. Store the expansion card in an anti-static bag (available from electronic supply stores) or a cardboard box. 6. Place an expansion slot cover in the space left by the expansion card you removed. For more details on the location and availability of the expansion card slots on your system's motherboard, see Motherboard on page 22.
137
User Guide
www.nec-computers.com
Figure 35: Three-connector IDE Cable A - Connects to the motherboard IDE port B - Red edge (Pin 1) C - Connects to IDE devices
138
User Guide
www.nec-computers.com
139
User Guide
www.nec-computers.com
A - Audio Cable - N/A B - IDE cable C - Red edge (Pin 1) D - Power cable
Note: Audio Cable is not available on this system.
140
User Guide
www.nec-computers.com
Figure 38: Cabling a SCSI Hard Disk Drive A - SCSI cable B - Power cable
141
User Guide
www.nec-computers.com
142
User Guide
www.nec-computers.com
2. Locate an available power connector coming from the power supply. 3. Connect the appropriate power cable to the cable power adaptor. 4. Connect the power cable adaptor to the connector on the storage device.
143
User Guide
www.nec-computers.com
Figure 42: Cabling a Floppy Disk Drive A - Data cable B - Purple edge (Pin 1) C - Power cable
144
User Guide
www.nec-computers.com
Figure 43: Connectors on the Back of an Optical Drive (example) A - Jumper block
145
User Guide
www.nec-computers.com
Refer to the Connectors on the Back of a Tape Drive (example) hereafter for details about configuring IDE drives as master or slave. Refer to the instructions printed on the device for further jumper setting information.
Figure 45: Connectors on the Back of a Tape Drive (example) A - Master Setting B - Slave Setting C - Cable Select
146
User Guide
www.nec-computers.com
147
User Guide
www.nec-computers.com
148
User Guide
www.nec-computers.com
Interrupt Requests
The factory-set interrupt requests (IRQs) are listed below. Find an appropriate one to install an optional device.
IRQ H
(X = used)
Caution
When using PCI cards on shared slots, ensure that the drivers support Share IRQ or that the cards do not need IRQ assignments. Otherwise, conflicts will arise between the two PCI groups, making the system unstable and the card inoperable.
149
User Guide
www.nec-computers.com
Note: Some of the utilities mentionned above may not be available on your server.
Note: Some of the features can be performed remotely using a cross cable (COM) or LAN.
Utilities
All the utilities described in the pages hereafter are not available on your server system. Most depend on your configuration.
150
User Guide
www.nec-computers.com
For instance, amid the several RAID configuration and management utilities listed, only the ones relevant to your RAID hardware (card or chipset) will be available.
151
User Guide
www.nec-computers.com
EXPRESSBUILDER
EXPRESSBUILDER is an automated software integration tool that helps simplify the process of installing and configuring your server. It provides a flexible, guided installation process for system administrators to install Microsoft Windows 2000 or Microsoft Windows ServerTM 2003. To install other operating systems, please contact your service representative for more information on the operating systems certified on the server.
Note: Before using EXPRESSBUILDER for initial setup, complete the hardware configuration.
EXPRESSBUILDER includes three distinct programs: DOS-based with local console Used to set up the server at the first time. This program is also used to diagnose the server and to install/uninstall the management utilities on the maintenance partition of the system drive. DOS-based with remote console Used to set up the server from the management workstation by accessing the server over the network or via serial port B.
Note:
This menu is displayed only when an optional remote management card is installed in your system.
152
User Guide
www.nec-computers.com
Windows-based This program is called "Master Control Menu" and runs under the Microsoft Windows system (Windows 95 or later and Windows NT 4.0 or later). You can install the several applications and read the documentation from this menu.
Caution
Do not remove the EXPRESSBUILDER CD-ROM while EXPRESSBUILDER is running.
1. 2. 3. 4.
Turn on first the peripheral devices and then the server. Insert the EXPRESSBUILDER CD-ROM supplied with your server into the CD-ROM drive of your server. Ensure that the floppy disk drive is empty. Press the RESET switch or press Ctrl, Alt, and Delete to reboot from the EXPRESSBUILDER. (You may also turn off and then on again to reboot the server.) EXPRESSBUILDER boots up displaying the top menu..
153
User Guide
www.nec-computers.com
Express Setup
"Express Setup" is intended for the initial setup of the server. Its automatic installation mode guides the user easily through the process by detailing specific hardware features and providing screen prompts for software selection and configuration. The program loads the utilities and drivers, applies RAID settings, partitions the disk, and installs the desired operating system. If you install Windows Server 2003 or Windows 2000, after a few tasks are completed, all that remains to be done is to remove the EXPRESSBUILDER CD-ROM, insert the Windows CD-ROM, input a product ID number, and acknowledge the license agreement.
Caution
The Express Setup is intended for the initial setup of the
server system and, therefore, the Express Setup clears the contents of the hard disk.
Tools
"Tools" is also intended for initial setup of the server. It allows additional installation options and allows the user to quickly create utility support disks, run the Off-line Maintenance Utility and system diagnostic utility, set up a maintenance partition, and update the various BIOS programs. Table 11: Tools Menu
Tools Menu
Save/Restore RAID Configuration Data Off-line Maintenance Utility System Diagnostics Create Support Disk Setup Maintenance Partition BIOS/FW/etc. Update Initialize Remote Management Card System Management Help Return to the Top Menu RAID Level: 7 Write Mode: WRITE_THRU Maint Part: Present RAID Board: Present Total Drives: 1 Drives in Group: 1 Hot Spares: 1
154
User Guide
www.nec-computers.com
Save/Restore RAID Configuration Data The item allows the configuration information on the disk array system to be saved or restored from the floppy disk. If the HostRAID and LSI-Logic disk array controllers are used together, the configuration information of HostRAID is saved or restored. If the Adaptec Zero channel raid controller (ZCR) and LSI-Logic disk array controller are used together, the configuration information of ZCR is saved or restored.
Warning
In these cases, If you want to save or restore the configuration information of LSI-Logic disk array controller, refer to the "Power Console Plus User's Guide".
- Save Disk Array Configuration Data The configuration information on the disk mirroring controller is saved into the floppy disk. If you set or change RAID, always use this function to save the configuration information into a floppy disk.
Warning
Some Disk Array Controllers do not support this function. In that case, this menu will not be shown.
- Restore Disk Array Configuration Data The configuration information saved in a floppy disk is restored to NVRAM and hard disk on the disk mirroring controller. If the configuration information is broken or changed by mistake, restore the configuration information. When the defective disk array controller is replaced, the configuration information on the hard disk must be saved into the disk array controller. However, if the configuration information on the new disk mirroring controller is saved into a hard disk, use this function to restore the configuration information.
Warning
Some Disk Array Controllers do not support this function. In
that case, this menu will not be shown.
Please do not use this function, except for maintenance. Off-line Maintenance Utility
155
User Guide
www.nec-computers.com
The Off-line Maintenance Utility is an OS-independent maintenance program that performs preventive maintenance and error analysis for your server. See the online help for details. System Diagnostics Executes various tests on the server system to check if the server functions are normal and if the connection between the server and additional board is normal. After the System Diagnostics is executed, a system check program assigned to each model starts. Create Support Disk The EXPRESSBUILDER CD-ROM contains a number of device drivers and utilities that you can put on floppy disks and load onto your system. Use this menu to create a support disk by copying from the EXPRESSBUILDER CD-ROM. If your system is running a Windows operating system, you may find it more convenient to use EXPRESSBUILDER for Windows-based to make support disks Write the displayed title on the floppy disk label, which is useful for management in the future. Customers are to provide a floppy disk to create a support disk. - Windows Server 2003 OEM-DISK for EXPRESSBUILDER Creates a support disk used for the installation of Windows Server 2003 Standard Edition and Windows Server 2003 Enterprise Edition. (No need to create this disk when installing the operating system with the Express Setup.) - Windows 2000 OEM-DISK for EXPRESSBUILDER Creates a support disk used for the installation of Windows 2000 Server and Windows 2000 Advanced Server. (This disk is used for Windows 2000 clean installation and for Recovery for Windows 2000 system.) (Not required when installing the operating system with the Express Setup.) - ROM-DOS Startup FD Creates a support disk used to start the ROM-DOS system. - Off-line Maintenance Utility Bootable FD Creates a support disk used to activate the Off-line Maintenance Utility. - System Management FD Creates a support disk used to activate the System Management. Setup Maintenance Partition The Maintenance partition is a specific partition for the server that is created on your system disk. About 55MB of the maintenance partition includes the various maintenance utilities and executable commands.
156
User Guide
www.nec-computers.com
Warning
Do not reset or turn off the server while running this menu. If
this process is interrupted, the system will not start anymore.
Notes:
- Create Maintenance Partition EXPRESSBUILDER creates a maintenance partition of about 55MB on the system disk (or disk array system) as work area. The various utilities are installed when the maintenance partition is created successfully or when the maintenance partition is already created. - Install Maintenance Partition Utilities Various utilities are installed in the maintenance partition from the CD-ROM. - Update Maintenance Partition Utilities Various utilities are copied in the Maintenance Partition from the update disk. This menu is only used when the update disk is supplied from your service representative or attached with your system. - FDISK Executes the FDISK command of the ROM-DOS system. You can create/delete partitions, etc.
157
User Guide
www.nec-computers.com
BIOS/FW/etc. Update This menu allows you to update the software module such as BIOS and firmware of the server by using the update disk (3.5-inch floppy disk) that is distributed from NEC customer service representative. After rebooting the system, an update program starts automatically from the floppy disk, and the various BIOS and firmware programs are updated.
Warning
Do not turn off the server while the update program is running. If this process is interrupted, the system will not start anymore.
Initialize Remote Management Card "Initialize Remote Management Card" is used to configure the Remote Management Card with correct parameters of the system installed it. System Management The parameters of the BMC (Baseboard Management Controller) are set for remote control and alert. Help Displays explanations about various functions of EXPRESSBUILDER. Return to the Top Menu Choosing this menu returns to the Top Menu.
Warning
Do not use this feature on any other computer than the
server, or on any other server obtained without EXPRESSBUILDER. Doing so may cause a failure of the server.
158
User Guide
www.nec-computers.com
The system may fail to operate with the transfer rate of 115.2
Kbps for serial console redirection. Specify any other transfer rate than 115.2 Kbps.
Starting The following two methods are available to start the server. Running EXPRESSBUILDER from the management PC via LAN Running EXPRESSBUILDER from the management PC via direct connection (COM B) For the procedure for starting EXPRESSBUILDER for DOS-based with Remote Console, see "Dianascope".
Warning
Do not change the boot device order in BOOT menu in BIOS
SETUP. EXPRESSBUILDER cannot be used if the CDROM drive is not the first boot device.
Notes: The following items of BIOS setup information will be set as shown below.
BIOS Redirection Port:[Serial B] Baud Rate:[19.2K] Flow Control:[CTS/RTS] Console Type:[PC ANSI]
Top Menu
159
User Guide
www.nec-computers.com
Setup: automatically sets up the server. Tools: launch the features of EXPRESSBUILDER individually. Help: help message on EXPRESSBUILDER. Quit: quit EXPRESSBUILDER.
Setup
EXPRESSBUILDER checks the hardware configuration of the server. The disk array and maintenance partition are automatically configured.
Tools
When you select the [Tools] on the Top Menu, the following screen appears.
The menu items available only in remote console operation among those described in section "EXPRESSBUILDER for DOS-based with Local Console" are displayed. See the previous subsection for detailed explanation of menu items.
Warning
The following differs from the [Tools] menu in the local console mode.
Notes:
160
User Guide
www.nec-computers.com
Insert the EXPRESSBUILDER CD-ROM into the CD-ROM drive, the Master Control Menu appears on the screen automatically. If the Autorun function is invalid in your system, run the \MC\1ST.EXE file in the CD-ROM directly. Some items are grayedout when the logon user does not have administrator authority, or if the item is not proper for the system. To use Master Control Menu, Click on [Online Document], [Setup] or [Quit], or Click the right mouse button on Master Control Menu window.
161
User Guide
www.nec-computers.com
Note: You can install Windows Server 2003 and Windows 2000 without a Configuration Diskette. Also, you can modify/ newly create the Configuration Diskette during the setup with EXPRESSBUILDER.
Creating Configuration Diskette This section describes how to specify the setup information required for OS installation and the creation of the Configuration Diskette. Follow the procedure below.
Note: In the procedure below, the folder name that is specified when installing the Trekking command is assumed as [Configuration Diskette Creator].
1. 2. 3. 4. 5. 6. 7.
Start the OS. Insert the EXPRESSBUILDER CD-ROM into the CD-ROM drive. Click Setup on the Master Control Menu. Click Configuration Diskette Creator. Click Create New Information files from the File menu. Specify each item and click OK. Follow the on-screen instructions to specify each item on the dialog box and click Next.
Note: If you click on Cancel, all the values already entered will be deleted.
Once you have finished completing the specification of setup information, the Save Setup Information dialog box will appear. 8. Make sure that the Configuration Diskette check box is checked, and type a file name for the Setup File in File Name. 9. Insert a 1.44MB floppy disk into the floppy disk drive and click OK.
162
User Guide
www.nec-computers.com
The Configuration Diskette is created; we recommend you label it and store it in a safe place. Use it to install Windows Server 2003 or Windows 2000. If you want to modify an existing information file, click Modify Information Files on the Configuration Diskette Creator Window. Refer to the Help file for more information.
5. When User and application setup is displayed, check Apply OEM-FD for mass storage device. 6. When the Save Setup Information dialog box is displayed, confirm that the Configuration Diskette check box is checked, and input file name for the Setup File in File Name. 7. Insert a 1.44MB floppy disk into the floppy disk drive and click OK.
163
User Guide
www.nec-computers.com
ESMPRO
ESMPRO lets a system administrator manage remote servers across a network. ESMPRO monitors server hardware and software configurations, failures, and performance. Using the log data collected by ESMPRO, a system administrator can track long-term and short-term performance, monitor server usage, create graphs to record trends, and check server failure rates. The administrator can use the information collected to create more efficient data routing procedures and optimize the server usage.
Caution
For installation procedure and detailed explanations on ESMPRO, refer to the online documentation provided on the EXPRESSBUILDER CD-ROM.
164
User Guide
www.nec-computers.com
DianaScope
DianaScope is a software used for the remote management of the Express5800 series. See the online documents for details on the functions and installation of DianaScope.
Note: You need the server license to activate DianaScope for this product.
165
User Guide
www.nec-computers.com
Features
Maintaining ZCR and HostRAID storage system. Making a consistency check on redundant disk arrays. Recording ZCR and HostRAID events into the event log. Omitting the installation of client software into each management PC if ASMBE is installed. Before attempting to operate ASMBE, read the Adaptec Storage ManagerTM - Browser Edition User's Guide included on the EXPRESSBUILDER CD-ROM.
166
User Guide
www.nec-computers.com
WebPAM
The Web-Based Promise Array Management (WebPAM) software offers local and remote management and monitoring of all FastTrak logical drives that exist anywhere on a network. The browser-based graphical user interface provides email notification of all major events/alarms, memory cache management, drive event logging, logical drive maintenance, rebuild, and access to all components in the RAID configuration (server, controller, logical drives, physical drives, and enclosure). For more information on using WebPAM, refer to the WebPAM Online Help.
167
User Guide
www.nec-computers.com
168
User Guide
www.nec-computers.com
Major Functions
Power Console Plus provides the following features: Support for the Wizard function in order to facilitate configuration Makes it possible to change of RAID level Compatible with SAF-TE Performance monitor support Supports enclosure functions such as temperature monitoring, power monitoring, and fan monitoring Enables the settings of Write, Read, and Cache policies for each logical drive Supports the save and restore functions for configuration Enables the display of the SCSI transfer rate
Components
Power Console Plus consists of the following five components: SNMP Agent (not supported) MegaRAID Service Monitor Enables ESMPRO to monitor the SecuRAID controller by registering event logs. Install MegaRAID Service Monitor in the Express server in which the SecuRAID controller is mounted. MegaRAID Client Controls the RAID system on graphical screens. Install MegaRAID Client in the Express server in which the SecuRAID controller mounted or in the management PC that is connected through the Express server and network. MegaRAID Server Enables control of the SecuRAID controller via the network. Install MegaRAID Server in the Express server in which the SecuRAID controller mounted. MegaRAID Registration Server
169
User Guide
www.nec-computers.com
Enables control of the SecuRAID controller via the network. Install in one of Express servers and management PCs that are connected through network. The above components must be installed correctly for establishing the environment to use Power Console Plus. Power Console Plus components to be installed are different between the target servers and management PC. Server (Express server in which the SecuRAID controller is mounted): Install the following three components in this server: - MegaRAID Service Monitor - MegaRAID Server - MegaRAID Client Management PC (Management PC that monitors and controls servers via the TCP/ IP network) When managing array on Terminal Server working on Windows NT Server Version 4.0 Terminal Server Edition, prepare PC, and install Management PC component. Management PC does not guarantee operation on Client, which used Terminal Server, Terminal Server Emulator, WBT. Start Power Console Plus of management PC, after the Power On machine that installed "Server" and "Management Server". Install the following component in this PC: - MegaRAID Client Management server (Machine that manages all servers that are monitored and controlled by management PCs): Install the following component in one of the servers or management PCs: - MegaRAID Registration Server
Server Setup
This section explains the Power Console Plus setup in the Express server in which the MegaRAID controller is mounted. Operating Environment Hardware - Machine: Express5800 series connected with the AMI disk array controller (A) - Memory: Size large enough for OS operation + 8MB or more - Free space of the hard disk: 5MB or more - Display unit: Screen size 1024 768 or larger
170
User Guide
www.nec-computers.com
- Required peripheral equipment: Network Interface card, CD-ROM unit, Pointing device such as a mouse Software - Microsoft Windows NT version 4.0 (Windows NT Version 4.0 Service Pack 5 or later + Internet Explorer 4.01 Service Pack 2 or later) - Microsoft Windows 2000
Management PC Setup
This section explains Power Console Plus setup in a computer that manages servers via the network (TCP/IP). Operating Environment Hardware - Machine: Express5800 series, PC/AT-compatible machine (which contains Intel Pentium or a CPU at least equivalent to it) - Memory: Size large enough for OS operation + 8MB or more - Free space of the hard disk: 5 MB or more - Display unit: Screen size 1024 768 or larger - Required peripheral equipment: Network Interface card, CD-ROM unit, Pointing device such as a mouse Software - Microsoft Windows NT Version 4.0 (Windows NT Version 4.0 Service Pack 5 or later + Internet Explorer 4.01 Service Pack 2 or later) - Microsoft Windows 2000 - Microsoft Windows 95/98/Me
171
User Guide
www.nec-computers.com
SCSISelect Utility
The SCSISelect Utility detects and configures the SCSI controller located on the system board or an optional SCSI controller board installed in your system. This utility may be started with a simple key operation while POST is in progress and requires no specific start-up disk. The SCSISelect Utility is used mainly to set the transfer rate of connected SCSI device. Use the SCSISelect Utility to: Change default values Check and/or change SCSI device settings that may conflict with those of other devices in the server.
Description
Configure host adapter and device settings. The utility scans the SCSI bus for SCSI devices, reports a description of each device. Run these utilities before configuring SCSI devices.
4. If you wish to format a disk, verify disk media, or display a list of devices and their SCSI IDs, select SCSI Disk Utilities. If you wish to configure the adapter or a device, select Configure/View Controller Settings.
Action
Up and down arrows move from one parameter to another within a screen. Displays options for a configurable parameter. Selects an option. Moves back to previous screen or parameter or EXIT if at the Main menu. Switches between color and monochrome. Resets to host adapter defaults.
172
User Guide
www.nec-computers.com
The following table shows the normal settings for the Adaptec SCSI Utility and provides a place for you to record any changes you make to these settings. Table 14: SCSISelect Utility Setup Configurations
OPTION SCSI Bus Interface Definitions SCSI Controller ID SCSI Controller Parity SCSI Controller Termination Additional Options Boot Device Configuration Master SCSI Controller Boot SCSI Controller SCSI Device Configuration Sync Transfer Rate (MB/Sec) Packetized QAS Initiate Wide Negotiation Enable Disconnection Send Start Unit Command BIOS Multiple LUN Support Include in BIOS Scan Advanced Configuration Reset SCSI Bus at IC Initialization Display <Ctrl-A> Messages During BIOS Initialization Extended Int13 Translation for DOS Drives >1 GByte POST Display Mode SCSI Controller Int13 Support Domain Validation Support Removable Disks Under Int13 as Fixed Disks BIOS Support for Bootable CDROM
1 No 2
RECOMMENDED SETTING OR DISPLAY ONLY 7 Enabled Enabled Press ENTER for menu 29320ALP slot 01 03:01:00 29320ALP slot 01 03:01:00 Press ENTER for menu 320 Yes Yes Yes Yes Yes No 1 Yes 1 Press ENTER for menu. Enabled Enabled Enabled
YOUR CONFIGURATION
Do not remove media from a removable media drive if it is under BIOS control.
173
User Guide
www.nec-computers.com
Scanning SCSI ID : 0
LUN Number : 0
When the SCSI ID scan completes, the screen listing SCSI IDs and associated devices appears.
Select SCSI Disk and press <Enter> SCSI ID #0 SCSI ID #1 SCSI ID #2 SCSI ID #3 SCSI ID #4 SCSI ID #5 SCSI ID #6 SCSI ID #7 SCSI ID #8 SCSI ID #9 : No device : No device : No device : No device : No device : No device : No device : Adaptec Adaptec29320ALP AIC-7901 : No device : No device
SCSI ID #10 : No device SCSI ID #11 : No device SCSI ID #12 : No device SCSI ID #13 : No device SCSI ID #14 : No device SCSI ID #15 : No device
With this screen you can determine the SCSI IDs of the installed options. You can also view the device information by selecting a device and pressing Enter. The following submenu appears.
SCSI ID#4: xxxxxxxxx Firmware: xxxx xxx Capacity: xxGB Format Verify Disk Media
The following table lists submenu items and descriptions.: Table 15: Submenu Items
Submenu item
Format Verify Disk Media
Description
Formats the selected device. Verifies all the sectors in the selected device. If one or more bad sectors are found, the sectors are remapped.
174
User Guide
www.nec-computers.com
HostRAIDTM
The following is an overview of HostRAID and explains the setup procedure.
Overview of HostRAID
HostRAID is an integrated RAID technology that adds entry level RAID support. It is also called intelligent RAID on chip (iROC) or software RAID and it is build into the firmware of the controller. There is no additional RAID processor on HostRAID cards. HostRAID is available for both Serial ATA and SCSI cards, though not for all of them. Check the specifications of the card installed in your system for support information. HostRAID configuration requires: A specific driver to control the disk arrays - refer to the setup procedure explained in this manual. "Adaptec Storage Manager - Browser Edition" (hereinafter referred to as "ASMBE"), which is a disk array management utility. Refer to the HostRAID (SATA) Adaptec Storage Manager Browser Edition User's Guide for the setup procedure. Also see Adaptec Storage Manager - Browser Edition on page 166.
Note: Since the JAVA-based management utility ASMBE uses the browser (IE5.5 or later), the software must be installed on each server, but not onto each client PC.
Features
Bootable array support Global Spares (minimum 1 spare, maximum 2 spares)
175
User Guide
www.nec-computers.com
Complete RAID configuration and management utility in the BIOS Provides graphical RAID management software Support for transparent array (data) migration to Adaptec Intelligent RAID cards Supports Hot Swap of drives Support for Auto Rebuild (if there is a spare) Support for Auto Verify
References
For more information on the BIOS setup utility, refer to BIOS Setup Utility on page 238. For more information on ASMBE, refer to Adaptec Storage Manager - Browser Edition on page 166.
176
User Guide
www.nec-computers.com
Note: You may view or print the HostRAID Adaptec Storage Manager Browser Edition User's Guide from the EXPRESSBUILDER CD-ROM.
177
User Guide
www.nec-computers.com
System Diagnostics
The System Diagnostics tool runs several tests on the system. Use the System Diagnostics program in the EXPRESSBUILDER CD-ROM provided with the system to diagnose the system.
Test Items
The following items are tested in system diagnostics. Memory CPU cache memory Hard disk used as a system
Caution
When executing the System Diagnostics, make sure to remove the LAN cable. When executing the System Diagnostics with the LAN cable connected, the network may be influenced.
Note: No data is written to the hard disk during the disk check.
178
User Guide
www.nec-computers.com
Caution
Use the serial port to execute System Diagnostics with remote console. The LAN connection is not for System Diagnostics.
Procedures to start the diagnostics program is as follows: 1. 2. 3. 4. 5. 6. Shutdown the OS, and turn off the system. Then, unplug the power cord. Disconnect all the LAN cables from the system. Plug the power cord and turn on the system. Reboot the system with the EXPRESSBUILDER CD-ROM. Select [Tools]. Select [System Diagnostics]. The System Diagnostics starts and completes in three minutes. When the diagnosis completes, the test window title shows "Test End". Diagnosis tool title: shows a name of this diagnosis and Version information. Test windows title: shows the progress of diagnosis. When it completes, it shows "Test End". Test Result: shows the information including time of start, end and progress, and result of the diagnosis. Guide line: shows a description of keys to navigate the window. Test window: Move the cursor and press Enter to view the detail of the diagnosis. If an error is detected during the System Diagnostics, the test result shows "Abnormal End" in red color. Move the cursor and press Enter on the diagnosis which error occurred. Take a note of the error message showed, and contact your sales agent.
179
User Guide
www.nec-computers.com
7. Follow the Guide line shown in the bottom of the screen and press Esc to show the End user Menu. <Test Result> shows the screen of the diagnosis completed aforementioned. <Device List> shows the information of all the devices connected. <Log Info> shows the log information and error messages of the diagnosis. it can be saved to a floppy disk. To save the log information to a floppy disk, insert a formatted floppy disk to a floppy disk drive and select <Save [F]>. <Option> change where to output log <Reboot> Restarts the system. 8. Select <Reboot> in the Enduser Menu above. The Express system restarts and EXPRESSBUILDER boot the system. 9. Exit EXPRESSBUILDER, and remove the CD-ROM from the optical device drive. 10. Turn off the system and unplug the power cord from the receptacle. 11. Reconnect all the LAN cables to the system. 12. Plug the power cord. This completes the System Diagnostics.
180
User Guide
www.nec-computers.com
Caution
Before installing the operating system, adjust the system date and time by using the BIOS setup utility "SETUP."
Caution
Express Setup is intended for the initial setup of the system. Therefore, it clears the contents of the hard disk.
For Microsoft Windows Server 2003 and Windows XP Professional, Express Setup automatically configures your system and installs the operating system. After a few tasks are completed, all that remains to be done is to remove the NEC EXPRESSBUILDER CD-ROM and set the Windows CD-ROM, input a product ID number, and acknowledge the license agreement.
181
User Guide
www.nec-computers.com
Installation Notice
This section explains precautions and matters you should be aware of before beginning the installation in order to install Windows Server 2003 or Windows XP Professional correctly. Supported Operating System on this Model The system supports Microsoft Windows Server 2003 Standard Edition (hereinafter, referred to as "Windows Server 2003") and Microsoft Windows XP Professional. When installing other operating systems, contact your sales dealer or the maintenance service representative. BIOS Specification Before installing the Operating System, verify if the BIOS specification of the hardware is correct. See BIOS Setup Utility on page 238.
Caution
Before starting the installation, complete all the process of
adding the optional device and the setup of Express system mainframe (BIOS and optional board specification)
182
User Guide
www.nec-computers.com
Installing on a RAID Pack If you want to install Windows Server 2003 on a volume, the RAID pack needs to be configured previously. Connecting Hard Disk Drive Connect an hard disk drive on which the operating system is not going to be installed after installing the operating system. Creating Partition Size The minimum size for the partition where the system is to be installed can be calculated from the following formula. Size necessary to install the system + Paging File Size + Dump File Size Size necessary to install the system= 2900 MB Paging File Size (Recommended)= Mounted Memory Size 1.5 Dump file Size= Mounted Memory Size + 12 MB
Caution
The above paging file size is necessary for collecting debug
information (memory dump). If you set the default value of paging file size smaller than the 'recommended' value, the accurate debug information (memory dump) may not be collected.
The maximum paging file size which can be set on one partition is 4095 MB. If the above paging file size exceeds 4095 MB, specify 4095 MB for the paging file size.
If you install any application program or the like, add necessary space to the partition to install these programs.
For example, if the mounted memory size is 512 MB, the minimally required partition size will be calculated by the above formula as follows: 2900 MB + (512 MB * 1.5) + (512 MB + 12 MB) = 4192 MB Re-installing to the hard disk which has been upgraded to Dynamic Disk You cannot re-install Windows Server 2003 with the current partition of the hard disk upgraded to Dynamic Disk kept remained. If you want to keep the current partition remained, see Appendix D to re-install the system.
183
User Guide
www.nec-computers.com
Disk Configuration (Concerning the area displayed as "EISA") In disk area, an area displayed as "EISA" may exist. This area is maintenance partition for saving configuration information and utilities. Do not delete the area.
2. Insert NEC EXPRESSBUILDER CD-ROM into the CD-ROM drive. The Choose Your Language prompt displays.
3. Click on one of the flags to choose a language. The Express Setup home page displays.
Express Setup: click here to install the Operating System. Tools: click here to access DOS tools Quit: click here to exit Express Setup
184
User Guide
www.nec-computers.com
5. Fill in the boxes. 6. Click on Start Installation. 7. The Configurations Settings OK dialog box displays. Click OK.
185
User Guide
www.nec-computers.com
186
User Guide
www.nec-computers.com
Server Security
To help prevent unauthorized entry or use of the server, the server may include several security features, both hardware and software.
187
User Guide
www.nec-computers.com
Notes: the keys are attached to the back panel of the system.
188
User Guide
www.nec-computers.com
Using Passwords
You can set either the user password, the supervisor password, or both passwords. If only the user password is set, you: Must enter the user password to enter BIOS Setup. Must enter the user password to boot the server if Password on Boot is enabled in the BIOS Setup. Must enter the user password to exit secure mode.
189
User Guide
www.nec-computers.com
If only the supervisor password is set, you: Must enter the supervisor password to enter BIOS Setup. Must enter the supervisor password to boot the server if Password on Boot is enabled in the BIOS Setup. Must enter the supervisor password to exit secure mode. If both passwords are set, you: May enter the user password to enter BIOS Setup. However, you will not be able to change many of the options. Must enter the supervisor password if you want to enter BIOS Setup and have access to all of the options. May enter either password to boot the server if Password on Boot is enabled in either the BIOS Setup. May enter either password to exit secure mode.
Secure Mode
Configure and enable the secure boot mode by using the BIOS Setup (See BIOS Setup Utility on page 238). When secure mode is in effect: You can boot the server and the operating system will run, but you must enter the user password to use the keyboard or mouse. You cannot turn off the server power or reset the server from the front panel switches. Secure mode has no effect on functions enabled via remote server management or power control via the watchdog timer. Taking the server out of secure mode does not change the state of system power. That is, if you press and release the power switch while secure mode is in effect, the system will not be powered off when secure mode is later removed. However, if the front panel power switch remains depressed when secure mode is removed, the server will be powered off.
Note: Some of the measures listed below may not be available on your server.
190
User Guide
www.nec-computers.com
Description
How to enter secure mode: - Setting and enabling passwords automatically places the server in secure mode. - If you set a hot-key combination (through Setup), you can secure the system simply by pressing the key combination. This means you do not have to wait for the inactivity time-out period. When the server is in secure mode: The server can boot and run the operating system, but mouse and keyboard input is not accepted until the user password is entered. At boot time, if a CD is detected in the optical device drive or a diskette in drive A, the system prompts for a password. When the password is entered, the server boots from CD or diskette and disables the secure mode. If there is no CD in the optical device drive or diskette in drive A, the server boots from drive C and automatically goes into secure mode. All enabled secure mode features go into effect at boot time. To leave secure mode: Enter the correct password(s).
In secure mode, the server will not boot from or write to a diskette unless a password is entered. To write protect access to diskette whether the server is in secure mode or not, use the Setup main menu, Floppy Options, and specify Floppy Access as read only.
Set a time out period so that keyboard and mouse input are not accepted. Also, screen can be blanked, and writes to diskette can be inhibited
Specify and enable an inactivity time out period of from 1 to 120 minutes. If no keyboard or mouse action occurs for the specified period, attempted keyboard and mouse input will not be accepted. The monitor display will go blank, and the diskette drive will be write protected (if these security features are enabled through Setup). To resume activity: Enter the correct password(s).
To control access to setting or changing the system configuration, set a supervisor password and enable it through Setup. If both the supervisor and user passwords are enabled, either can be used to boot the server or enable the keyboard and/or mouse, but only the supervisor password will allow Setup to be changed. To disable a password, change it to a blank entry in the Change Password menu of the Supervisor Password Option menu found in the Security Subsystem Group. To clear the password if you cannot access Setup, change the Clear Password jumper (see BIOS Security Features Menu on page 250).
191
User Guide
www.nec-computers.com
Description
To control access to using the system, set a user password and enable it through Setup. To disable a password, change it to a blank entry in the Change Password menu of the User Password Option menu found in the Security Subsystem Group. To clear the password if you cannot access Setup, change the Clear Password jumper (see BIOS Security Features Menu on page 250).
The server can boot with or without a keyboard. During POST, before the system completes the boot sequence, the BIOS automatically detects and tests the keyboard if it is present and displays a message. The sequence that you specify in setup will determine the boot order. If secure mode is enabled (a user password is set), then you will be prompted for a password before the server fully boots. If secure mode is enabled and the "Secure Boot Mode" option is also enabled, the server will fully boot but will require a password before accepting any keyboard or mouse input.
192
User Guide
www.nec-computers.com
Maintenance
This chapter describes the daily maintenance of the system and precautions when relocating or storing the system.
193
User Guide
www.nec-computers.com
Cleaning
Clean the system on a regular basis to keep the system in a good shape.
Warning
Do not disassemble, repair, or alter the system Do not look into the optical device drive Do not remove the lithium battery Disconnect the power plug before working with the system
Caution
Avoid installation in extreme temperature conditions Make sure to complete board installation
Caution
To avoid altering the material and color of the system, do not
use volatile solvents such as thinner and benzene to clean the system.
For daily cleaning, wipe the external surfaces of the system with a dry soft cloth If stains remain on the surfaces: 1. Make sure that the system is off-powered (the POWER/SLEEP lamp goes off).
194
User Guide
www.nec-computers.com
2. Unplug the power cord of the system from a power outlet. 3. Wipe off dust from the power cord plug with a dry cloth. 4. Soak a soft cloth in neutral detergent that is diluted with cold or lukewarm water, and squeeze it firmly. 5. Rub off stains on the system with the cloth prepared in Step 4. 6. Soak a soft cloth in water, squeeze it firmly, wipe the system with it once again. 7. Wipe the system with a dry cloth. 8. Wipe off dust from the fan exhaust opening on the rear of the system with a dry cloth.
Warning
Unplug all power cords before performing any maintenance. Voltage is present inside the system and display unit even after the power is turned off. All voltage is removed only when the power cord is unplugged.
Caution
Do not use the brush made of chemical fabric, or the cleaning material that will generate an electrostatics.
To clean the interior of the system: 1. Turn off the system and unplug all power cables.
195
User Guide
www.nec-computers.com
2. Remove the logic cover and the drive cover. 3. Use a small brush to loosen any dust and debris on the mother board. 4. Use computer grade canned air to blow dust off components on the motherboard. 5. Use a small vacuum cleaner with plastic tip to vacuum out dust and debris from the interior of the system. 6. Reinstall the logic cover and the drive cover. 7. Reconnect all power cables and turn on the system.
196
User Guide
www.nec-computers.com
To Clean an Optical Drive: 1. Power the system. The POWER/SLEEP lamp is lit. 2. Press the optical drive tray Open/Close button on the front of the optical drive. The tray os openning. 3. Hold the CD-ROM/CD-RW or DVD-Rom and take it out from the tray.
Note: Do not touch the signal side of the CD-ROM with your hand.
Caution
Do not wipe the lens of the optical drive. Doing so may damage the lens and may cause a malfunction of the drive.
5. Push on the tray front to close the tray. To Clean a CD-Rom or CD-RW or DVD-Rom: Wipe the signal side of the disk with a dry soft cloth.
Caution
Wipe disks from the center to the outside. Use only CD-ROM cleaner if necessary. Cleaning a CDROM or CD-RW or DVD-ROM with record spray/cleaner, benzene, or thinner causes damage to the disk contents. At worst, inserting the disk into the system may cause failure.
197
User Guide
www.nec-computers.com
Protect the system from extremely low or high temperatures. Let the system warm (or cool) to room temperature before using it.
Keep the system dry. Do not wash the system with a wet cloth or pour fluid into it.
Check the system for condensation. If condensation exists, allow it to evaporate before powering on the system.
198
User Guide
www.nec-computers.com
Solving Problems
This chapter helps you identify and solve problems that may occur during system installation or while using your system. The first section of this chapter tells you how to reset your system in the event of problems. The next few sections provide troubleshooting checklists and procedural steps that help you isolate specific system problems. The last section includes BIOS and system user information.
Warning
The DC push-button on/off switch on the front panel does not turn off completely the system AC power. +5vdc is present on the system board whenever the AC power cord is connected between the system and an AC outlet. Before doing the procedures in this manual, make sure that your system is powered off and unplug the AC power cords from the back of the chassis. Not disconnecting power before opening your system can result in personal injury and equipment damage
Caution
Running your system with the cover removed can damage your system components. For proper cooling and airflow, always replace the covers before powering on your system.
Static Precautions
An electrostatic discharge (ESD) can damage disk drives, option boards, and other components. You can provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground when handling system components. Electronic devices can be easily damaged by static electricity. To prevent damage, keep them in their protective packaging when they are not installed in your system.
199
User Guide
www.nec-computers.com
Troubleshooting Guide
This section provides you a guide to identify a problem and locate its source.
Warning
The system power and any peripheral devices should be turned off before connecting or disconnecting peripheral devices to or from the system. Otherwise, you could permanently damage the system or peripheral devices.
1. Turn off the system and any peripheral devices. Disconnect all external peripherals from the system, except for the keyboard and monitor. The systems power cord must be plugged into a grounded electrical outlet. 2. Make sure your keyboard and monitor are properly connected to the system. Turn the monitor on, then adjust its brightness and contrast controls to suit your preference (see your monitors documentation). 3. Turn the system on. If the power indicator does not light up, but the system seems to be operating normally, the indicator may need replacement. 4. Monitor the power-on self test (POST) execution. Each time you turn on the system, the POST checks the system board, memory, keyboard, and certain peripheral devices. 5. Check the following during the POST:
IfthePOSTdoesnotdet ctanyerors,thesystemshouldbo tup. Erorsthatdonotprevent hebo tproces (non-fat lerors)displayames agethatmayap earsimilartothefol wingdisplay:
(Error Message Line 1) (Error Message Line 2) Press <F1> to continue, <F2> to enter Setup You should note the error and press F1 to resume the boot-up process, or F2 to enter Setup. 6. Errors that prevent the boot process from continuing (fatal errors) are communicated by a series of audible beeps. If this type of error occurs, record the information and refer to the Error Messages: Beep Codes section.
System Viewers
Monitor the occurrence of fault by ESMPRO during the system operation. Especially take note on whether any alert is reported to ESMPRO Manager on the management PC. Check whether any alert is reported on the Operation Window, Data Viewer, or Alert Viewer of ESMPRO Manager.
200
User Guide
www.nec-computers.com
Lamps
The server includes lamps to indicate the server states by a variety of colors and display patterns on the front panel, hard disk drive, and power supply. Refer toStatus Indicators on page 20 for more information.
201
User Guide
www.nec-computers.com
What to do
Make sure all cables are installed correctly. Verify that your system hardware configuration is set correctly. In Setup, check the values against the system settings that you previously recorded. If an error is evident (wrong type of drive specified, for example), make the change in Setup and reboot the system. Record your change. Make sure the software is properly configured for the system. Refer to the software documentation for information. Try a different copy of the software to see if the problem is with the copy you are using. If other software runs correctly on the system, contact the vendor of the failing software.
Make sure the brightness and contrast controls are properly adjusted. Make sure the monitor's video signal cable and power cables are properly installed. (Shut down system power before reconnecting cables.) Make sure your monitor is compatible with the video mode you have selected. (Check your monitor's documentation.) Characters do not appear on screen Make sure the monitor is plugged in and turned on. Are the brightness and contrast controls properly adjusted? Make sure that the video signal cable is properly connected. (Turn the system power off before reconnecting cables). Make sure your system's video adapter card is installed, enabled. Reboot the system. CMOS RAM settings are wrong If system settings stored in CMOS RAM change for no apparent reason (for example, the time of day is in error), the backup battery may no longer have enough power to maintain the settings. Replace the battery. Diskette drive light does not go on Make sure the power and signal cables for the drive are properly installed. when drive is in use or is tested by Check that the drive is properly configured and enabled in Setup. POST. Hard drive light does not go on when drive is in use or is tested by POST. Make sure the power and signal cables for the drive are properly installed. Make sure the front panel connector is securely attached to the system board headers. Check that the drive is properly configured and enabled in Setup. Check the drive manufacturer's manual for proper configuration for remote hard disk drive activity. If the system is operating normally, check the connector between the system board and the front panel. If OK, the light may be defective.
202
User Guide
www.nec-computers.com
203
User Guide
www.nec-computers.com
Did you perform any keyboard or mouse operation immediately after you started the server? - If you perform any keyboard or mouse operation immediately after start-up, POST may accidentally detect a keyboard controller error and stops proceeding. In such a case, restart the server once again. Do not perform any keyboard or mouse operation until the BIOS start-up message appears when you restart the server. Does the server contain appropriate memory boards or PCI devices? - Operation of the server with unauthorized devices is not guaranteed. Fail to access to internal or external devices (or such devices fail to operate): Are cables properly connected? - Make sure that the interface cables and power cord are properly connected. Also make sure that the cables are connected in the correct order. Is the power-on order correct? - When the server has any external devices connected, power on the external devices first, then the server. Did you install drivers for connected optional devices? - Some optional devices require specific device drivers. Refer to the manual that comes with the device to install its driver. Is BIOS configuration correct? - Some devices connected to the serial or parallel port may require I/O port address or operation mode settings. Refer to the manual that comes with the board for details to make correct settings. The Power switch and sleep features are disabled: Is the server in Secure mode? - In the Secure Mode, the Power switch and sleep feature are disabled. To release the Secure mode, enter the password specified with the BIOS Setup utility. The keyboard or mouse fails to operate: Is the cable properly connected? - Make sure that the cable is connected to the correct connector on the rear of the server. - The keyboard or mouse does not operate if it is connected when the server is powered (not applicable to USB devices). Power of the server first and connect it properly. Are the server drivers installed?
204
User Guide
www.nec-computers.com
- Refer to the manual that comes with your OS to check that the keyboard and mouse drivers are installed. (These drivers are installed along with the OS.) Some OS's allow you to change the keyboard and mouse settings. Refer to manual that comes with your OS to check that the keyboard and mouse settings are correct. Fail to access (read or write) to the floppy disk: Does the floppy disk drive contain a floppy disk? - Insert a floppy disk into the floppy disk drive until it clicks. Is the floppy disk write-protected? - Place the write-protect switch on the floppy disk to the "Write-enabled" position. Is the floppy disk formatted? - Use a formatted floppy disk or format the floppy disk in the floppy disk drive. Refer to the manual that comes with the OS for formatting a floppy disk. Fail to access to the CD-ROM: Is the CD-ROM properly set in the CD-ROM drive tray? - The tray is provided with a holder to secure the CD-ROM. Make sure that the CD-ROM is placed properly in the holder. Is the CD-ROM applicable to the server? - The CD-ROM for Macintosh is not available for use. - For the disk which does not conform to the CD standard, the playback of such a disk with the CD drive is not guaranteed. Inserted the correct CD-ROM but an error message is displayed:
The CD-ROM is not inserted or the wrong CD-ROM is inserted. Please insert the correct CD-ROM. OK
Is the data side of the CD-ROM dirty or injured? - Take the CD-ROM out of the CD-ROM drive, check that it is not dirty or injured, reset and click [OK]. Fail to access the hard disk (Refer to the documentation supplied with the disk array controller.) Is the hard disk applicable to the server? - Operation of any device that is not authorized by NEC is not guaranteed. Is the hard disk properly installed?
205
User Guide
www.nec-computers.com
Is the hard disk properly configured? Fail to access the (internal or external) SCSI devices: Is the SCSI device applicable to the server? - Operation of any SCSI device that is not authorized by NEC is not guaranteed. Is the cable connection changed? Are SCSI devices properly configured? - When the server has external SCSI devices connected, devices settings, including SCSI ID and terminator, are required. Refer to the manual that comes with the SCSI device for details. Is cable length exceeded? - Refer to the manual that comes with the SCSI device for details. Are the optional SCSI controllers properly configured? - When the server has an optional SCSI controller installed and SCSI devices connected to it, use the POST Setup utility that comes with the optional SCSI controller for proper configuration. See the manual that comes with the optional SCSI controller for details. The server is not found on the network: Is the LAN cable connected? - Make sure to connect the LAN cable to the network port on the rear of the server. Also make sure that the LAN cable to use conforms with the network interface standard. Is the BIOS configuration correct? - The internal LAN controller may be disabled with the BIOS SETUP utility of the server. Check the setting with the BIOS SETUP utility. ave the protocol and service already configured? - nstall the distinctive network driver for the server. Make sure that the protocol, such as TCP/IP, and services are properly specified. s the transfer speed correct? - Open the network property dialog box in control panel to specify the "Link Speed & Duplex" value the same as the value specified for HUB. Wake on LAN does not start from standby state. s Hub set to Auto-Negotiation? Or, Is the client set to Auto-Negotiation/optimum speed?
206
User Guide
www.nec-computers.com
- For both hub and client, Wake on LAN does not start from the standby state if the speed is fixed to 1000Mbps.
207
User Guide
www.nec-computers.com
The OS presents unstable operation: Did you update the system? - Installing a network drive after installation of the OS may cause unstable operation. Use the EXPRESSBUILDER CD-ROM to update the system. The system does not restart automatically when a stop error occurs, though the system is adjusted to automatically restarting: - When the system does not restart automatically, restart it manually. The system restarts automatically when a stop error occurs, though the system is NOT adjusted to automatically restarting: - There is no problem about this issue. Check the System Event Log to check that STOP error occurred. Cannot turn the power OFF at the blue screen: - If you want to turn off the power at the blue screen, execute forced shutdown (forced shutdown: continue to press POWER/SLEEP switch for 4 seconds). The power will not be turned off if you press the switch for less than 3 seconds. The PXE boot (network boot) fails or the server is not found on the network: Is the cable connected properly? - Connect the proper cable to the network port on the rear of the Express server. In addition, make sure that the used cable conforms to the network interface standard. Is BIOS configuration correct? - The internal LAN controller may be disabled with the CMOS Setup utility of the server. Check the setting with the BIOS setup utility. Have the protocol and service already configured? - Install the distinctive network driver for the server. Make sure that the protocol, such as TCP/IP, and services are properly specified. Is the transfer speed correct? - Open the network property dialog box in control panel to specify the link speed and duplex value the same as the value specified for HUB.
208
User Guide
www.nec-computers.com
- If you do not set the EXPRESSBUILDER during POST and restart the server, an error message will appear or the OS will boot. Is BIOS configuration correct? - The boot device order may be specified with the CMOS Setup utility of the server. Use the CMOS Setup utility to change the boot device order to boot the system from the CD-ROM drive first. <Menu to check: [Boot]> Has an error message appeared? - When an error occurs while the EXPRESSBUILDER is in progress, the following message appears. After this message appears, check the error and take the appropriate corrective action according to the message listed in the table below. Table 18: Error Messages
Message
This machine is not supported
NvRAM access error The system-specific information does not exist on the baseboard. Please restore the backup data or write the data by using [System Information Management] of the Off-line Maintenance Utility. Only the authorized personnel are allowed to do this operation.
209
User Guide
www.nec-computers.com
Express Setup terminated and asks to input setup information. - There are some errors on the specified setup information. Follow the instruction to input the correct value. It is not necessary to cancel the installation. On Windows 2000, you might be asked to press Enter again after the last reboot of the setup. [Complete] appears on the [Role of Computer] screen. - If you select [Complete] here, the setup will select the default value of Express Setup for the later specification to continue the process. Table 19: Default Value for Windows 2000
Specification of network Protocol
Protocol Service Client Component Application TCP/IP[DHCP Specified] Select sharing Microsoft network files and printer. Microsoft network client. SNMP, IIS (Excluding Professional) ESMPRO Agent Power Console Plus (When the optional SCSI RAID controller is installed) FastCheck (When the optional RAID S-ATA controller is installed)
[Complete] does not appear on [Role of Computer] screen. - The [Complete] does not appear if the Setup File that has already been created is loaded. - [Complete] appears only when you first entered the [Role of Computer] screen. Once you go to the next screen from [Role of Computer], the [Complete] will not appear even if you enter [Back] to go back to the [Role of Computer] screen. Selected [Use Existing Array] at [New/Existing RAID Configuration], but the OS is installed in the whole area of the disk. - Is there any other partition than the partition to re-use (excluding maintenance area)? If no other partition exist, the setup will reserve the whole area of the disk to install operating system. Specified to join the Domain, but the system is installed as Workgroup. - When the setup fails to join the Domain during the installation, it will install the system as Workgroup. Open [System] in Control Panel to specify joining the Domain. Specified large value as partition size, but when Windows 2000 is actually started, the system partition is created by 4095MB.
210
User Guide
www.nec-computers.com
- Is the [Partition Size] specified by the value larger than the real area? If you want to create one partition in all area of the hard disk (excluding the maintenance area) to install the OS, specify [All Area]. Windows 2000 started with different display resolution from the specified value. - If the specified display resolution can not be used, the system will use the nearest value or the default value of the driver. Entered the incorrect Product ID/CD key. - Even if you entered the incorrect Product ID/CD key, Express Setup will start. However, the setup will stop and asks you to re-enter the correct value. Also in this case, input request will occur when rebooting after GUI setup completed during Express Setup. If these 2 inputs are done correctly, there is no problem on Windows 2000 setup. Unable to specify the details of Network adapter. - In Express Setup, you can not specify the details of Network adapter. Specify them from Control Panel after starting Windows 2000. Windows 2000 is started with Network adapter that has not been specified during Express Setup - Windows 2000 will install the recognized Network adapter specified as default value. If you want to modify the specification, it can be done from Control Panel after starting Windows 2000. Also, the Network adapter that has been specified during Express Setup but that is not connected will not be setup, though the protocol will only be installed. Connected more than two Network adapter and specified different protocol for each adapter, but all the protocols are specified on either adapter. - It's a design. Each adapter is specified so that all the installed protocols can be used. The value that can not be specified during Express Setup will all be specified by default value. When more than two Network adapter are specified, the detailed specification of TCP/IP protocol are all set to use DHCP. - When more than two Network adapter are specified, the detailed specification of the protocol may all be set by default value. Re-specify the details from Control Panel. Not more than two Network adapter is connected, but the detailed specification of the protocol are all set by default.(e.g. Specified IP Address on TCP/IP, but DHCP is specified) - Are you specifying more than two protocols? In this case, the situation will be the same as connecting more than two Network adapter, so the detailed specification of the protocol are all set by default. Re-specify the details from Control Panel after starting the OS.
211
User Guide
www.nec-computers.com
212
User Guide
www.nec-computers.com
Caution
If STOP error, system error, or stall occurred, follow the procedure below after restarting the system.
1. Click [Management Tool]: [Event Viewer] from the Control Panel. 2. Select the type of the log to collect. On [Application Log], the events related to the running application is archived. On [Security Log], the events related to the security is archived. On [System Log], the events occurred at the item which configures Windows system is archived. 3. Click [Save as...] in the [Run] menu. 4. Input the file name of archived log in the [File Name] box. 5. Select the type of the log file you want to save in the [File Type] list box and click [OK]. For more information, refer to Windows Online Help.
213
User Guide
www.nec-computers.com
Caution
If STOP error, system error, or stall occurred, follow the procedure below after restarting the system.
1. Point to [Settings] in Start menu, and click [Control Panel]. The [Control Panel] dialog box appears. 2. Double-click [Management Tool], and double-click [Computer Management]. The [Computer Management] dialog box appears. 3. Click [System Tool]: [System Information]. 4. Click [Save as System Information File] in the [Operation] menu. 5. Enter the file name to save in the [File Name] box. 6. Click [Save].
214
User Guide
www.nec-computers.com
215
User Guide
www.nec-computers.com
Caution
Consult with your sales agent before dumping the memory.
Dumping the memory while the server is in process may affect the system operation.
Restarting the system due to an error may display a message indicating insufficient virtual memory. Ignore this message and proceed. Restarting the system may result in dumping improper data.
216
User Guide
www.nec-computers.com
Pressing the DUMP switch saves the dump file in the specified directory. (Memory dumping may not be available when the CPU stalls.)
Warning
Do not use a toothpick or plastic stick that could break easily. Do not use any pin easily broken such as a toothpick or plastic pin.
217
User Guide
www.nec-computers.com
Caution
The Off-line Maintenance Utility is intended for use of your
sales agent. The EXPRESSBUILDER CD-ROM and the Off-line Maintenance Utility Bootable FD you have created contain a file that describes operation of the utility, but do not attempt to use the utility by yourself. Contact your sales agent and follow instructions.
Caution
Do not start the Off-line Maintenance Utility while the server is in successful operation.
From the CD-ROM Set the EXPRESSBUILDER CD-ROM in the CD-ROM drive and reboot the system. After the menu is displayed on the screen, select "Tools" - "Off-line Maintenance Utility". The Off-line Maintenance Utility program starts from the CD-ROM. From the floppy disk Set the Off-line Maintenance Utility Bootable FD in the floppy disk drive and reboot the system. The Off-line Maintenance Utility program starts from the boot disk. The Off-line Maintenance Utility Bootable FD is created by selecting "Tools" "Create Support FD" on the EXPRESSBUILDER. Manual start (by pressing F4)
218
User Guide
www.nec-computers.com
When the Off-line Maintenance Utility is installed, press F4 while the start-up screen of the server is on screen. The Off-line Maintenance Utility starts from the hard disk.
Caution
See the on-line help for details of the Off-line Maintenance Utility. For further information, ask your sales agent.
IPMI Information Viewer Provides the functions to view the system event log (SEL), sensor data record (SDR), and field replaceable unit (FRU) and to make a backup copy of them. Using this feature, you can find system errors and events to determine a maintenance part. BIOS Setup Viewer Provides the functions to export the current configuration data defined with the SETUP utility to a text file. System Information Viewer Provides the functions to view information on the processor and the BIOS and export it to a text file. System Information Management Provides the function to make a back-up copy of your data. Without the backup data, the system-specific information and/or configuration may not be restored. Only the authorized personnel is allowed to restore the backup data. Start of Utilities With the EXPRESSBUILDER, you can start the following utilities installed in the maintenance partition. System Management System Diagnostics Maintenance Partition Update
219
User Guide
www.nec-computers.com
Chassis Identify This function can distinguish the machine with the lamp or buzzer of the machine. This is convenient if you have to distinguish a machine among many machines on the rack.
220
User Guide
www.nec-computers.com
Note: Refer to the warranty booklet delivered with your system to find out how to contact the local office in your country.
For technical support such as BIOS upgrades, consult our Web site at the following address: http://www.nec-computers.com.
221
User Guide
www.nec-computers.com
222
User Guide
www.nec-computers.com
223
User Guide
www.nec-computers.com
224
User Guide
www.nec-computers.com
225
User Guide
www.nec-computers.com
226
User Guide
www.nec-computers.com
227
User Guide
www.nec-computers.com
Error Messages
This section describes the POST error codes and messages.
The BIOS is unable to properly control the motherboards Gate A20 function, which controls access of memory over 1 MB. This may indicate a problem with the motherboard. Multi-Bit ECC Error This message will only occur on systems using ECC enabled memory modules. ECC memory has the ability to correct single-bit errors that may occur from faulty memory modules. A multiple bit corruption of memory has occurred, and the ECC memory algorithm cannot correct it. This may indicate a defective memory module. Parity Error Fatal Memory Parity Error. System halts after displaying this message. RAM R/W test failed This message is displayed by the AMIBIOS8 when the RAM read/write test fails. CMOS Memory Size The base memory (memory below 1MB) size that is Wrong reported in the CMOS (offset 15h) mismatches with the actual size detected. This condition may occur when the hole is set at 512K base memory or when CMOS is corrupted.
Gate20 Error
228
User Guide
www.nec-computers.com
This is a generic message indicating the BIOS could not boot from a particular device. This message is usually followed by other information concerning the device. Invalid Boot Diskette A diskette was found in the drive, but it is not configured as a bootable diskette. Drive Not Ready The BIOS was unable to access the drive because it indicated it was not ready for data transfer. This is often reported by drives when no media is present. A: Drive Error The BIOS attempted to configure the A: drive during POST, but was unable to properly configure the device. This may be due to a bad cable or faulty diskette drive. The BIOS attempted to configure the B: drive during POST, but was unable to properly configure the device. This may be due to a bad cable or faulty diskette drive. Insert BOOT disThe BIOS attempted to boot from the A: drive, but kette in A: could not find a proper boot diskette. Reboot and Select BIOS could not find a bootable device in the system proper Boot device or and/or removable media drive does not contain media. Insert Boot Media in selected Boot device NO ROM BASIC This message occurs on some systems when no bootable device can be detected. B: Drive Error
229
User Guide
www.nec-computers.com
Primary Master Hard Disk Error or Primary Slave Hard Disk Error Secondary Master Hard Disk Error or Secondary Slave Hard Disk Error
3rd Master Hard Disk Error
The IDE/ATAPI device configured as Primary Master/ Slave could not be properly initialized by the BIOS. This message is typically displayed when the BIOS is trying to detect and configure IDE/ATAPI devices in POST. The IDE/ATAPI device configured as Secondary Master/Slave could not be properly initialized by the BIOS. This message is typically displayed when the BIOS is trying to detect and configure IDE/ATAPI devices in POST.
The IDE/ATAPI device configured as Master/Slave in the 3rd IDE controller could not be properly initialized by the BIOS.
or
3rd Slave Hard Disk Error 4th Master Hard Disk Error
This message is typically displayed when the BIOS is trying to detect and configure IDE/ATAPI devices in POST.
The IDE/ATAPI device configured as Master/Slave in the 4th IDE controller could not be properly initialized by the BIOS.
This message is typically displayed when the BIOS is trying to detect and configure IDE/ATAPI devices in POST.
The IDE/ATAPI device configured as Master/Slave in the 5th IDE controller could not be properly initialized by the BIOS.
or
5th Slave Hard Disk Error 6th Master Hard Disk Error
This message is typically displayed when the BIOS is trying to detect and configure IDE/ATAPI devices in POST.
The IDE/ATAPI device configured as Master/Slave in the 6th IDE controller could not be properly initialized by the BIOS.
or
6th Slave Hard Disk Error
Primary Master Drive - ATAPI Incompatible or Primary Slave Drive - ATAPI Incompatible
This message is typically displayed when the BIOS is trying to detect and configure IDE/ATAPI devices in POST. The IDE/ATAPI device configured as Primary/Secondnary Slave failed an ATAPI compatibility test. This message is typically displayed when the BIOS is trying to detect and configure IDE/ATAPI devices in POST.
230
User Guide
www.nec-computers.com
The IDE/ATAPI device configured as Secondary Master/Slave failed an ATAPI compatibility test. his message is typically displayed when the BIOS is trying to detect and configure IDE/ATAPI devices in POST.
The IDE/ATAPI device configured as Master/Slave in the 3rd IDE controller failed an ATAPI compatibility test.
or
This message is typically displayed when the BIOS is 3rd Slave Drive - ATAPI trying to detect and configure IDE/ATAPI devices in Incompatible POST.
4th Master Drive ATAPI Incompatible The IDE/ATAPI device configured as Master/Slave in the 4th IDE controller failed an ATAPI compatibility test.
or
4th Slave Drive ATAPI Incompatible 5th Master Drive ATAPI Incompatible
This message is typically displayed when the BIOS is trying to detect and configure IDE/ATAPI devices in POST. The IDE/ATAPI device configured as Master/Slave in the 5th IDE controller failed an ATAPI compatibility test. This message is typically displayed when the BIOS is trying to detect and configure IDE/ATAPI devices in POST.
The IDE/ATAPI device configured as Master/Slave in the 6th IDE controller failed an ATAPI compatibility test.
or
5th Slave Drive ATAPI Incompatible 6th Master Drive ATAPI Incompatible
or
6th Slave Drive ATAPI Incompatible
This message is typically displayed when the BIOS is trying to detect and configure IDE/ATAPI devices in POST. The BIOS tried to send a S.M.A.R.T. message to a hard disk, but the command transaction failed. This message can be reported by an ATAPI device using the S.M.A.R.T. error reporting standard. S.M.A.R.T. failure messages may indicate the need to replace the hard disk. The BIOS tried to send a S.M.A.R.T. message to a hard disk, but the command transaction failed. This message can be reported by an ATAPI device using the S.M.A.R.T. error reporting standard. S.M.A.R.T. failure messages may indicate the need to replace the hard disk.
231
User Guide
www.nec-computers.com
A S.M.A.R.T. capable hard disk sends this message when it detects an imminent failure. This message can be reported by an ATAPI device using the S.M.A.R.T. error reporting standard. S.M.A.R.T. failure messages may indicate the need to replace the hard disk. A S.M.A.R.T. capable hard disk sends this message when it detects an imminent failure. This message can be reported by an ATAPI device using the S.M.A.R.T. error reporting standard. S.M.A.R.T. failure messages may indicate the need to replace the hard disk.
BootSector Write !!
The BIOS has detected software attempting to write to a drives boot sector. This is flagged as possible virus activity. This message will only be displayed if Virus Detection is enabled in AMIBIOS setup. If the BIOS detects possible virus activity, it will prompt the user. This message will only be displayed if Virus Detection is enabled in AMIBIOS setup.
DMA-1 Error
DMA-2 Error
Error initializing primary DMA controller. This is a fatal error, often indication a problem with system hardware. Error initializing secondary DMA controller. This is a fatal error, often indication a problem with system hardware. POST error while trying to initialize the DMA controller. This is a fatal error, often indication a problem with system hardware. BIOS could not write to the NVRAM block. This message appears when the FLASH part is writeprotected or if there is no FLASH part (System uses a PROM or EPROM).
232
User Guide
www.nec-computers.com
Microcode Error
NVRAM Checksum Bad, NVRAM Cleared Resource Conflict NVRAM Ignored NVRAM Bad
BIOS could not find or load the CPU Microcode Update to the CPU. This message only applies to INTEL CPUs. The message is most likely to appear when a brand new CPU is installed in a motherboard with an outdated BIOS. In this case, the BIOS must be updated to include the Microcode Update for the new CPU. There was an error in while validating the NVRAM data. This causes POST to clear the NVRAM data. More than one system device is trying to use the same non-shareable resources (Memory or I/O). The NVRAM data used to store PlugnPlay (PnP) data was not used for system configuration in POST.
The NVRAM data used to store PlugnPlay (PnP) data was not used for system configuration in POST due to a data error. Static Resource Con- Two or more Static Devices are trying to use the flict resource space (usually Memory or I/O). PCI I/O conflict A PCI adapter generated an I/O resource conflict when configured by BIOS POST. PCI ROM conflict A PCI adapter generated an I/O resource conflict when configured by BIOS POST. A PCI adapter generated an I/O resource conflict when configured by BIOS POST. PCI IRQ routing BIOS POST (DIM code) found a PCI device in the table error system but was unable to figure out how to route an IRQ to the device. Usually this error is causing by an incomplete description of the PCI Interrupt Routing of the system. Timer Error Indicates an error while programming the count register of channel 2 of the 8254 timer. This may indicate a problem with system hardware. Refresh timer test BIOS POST found that the refresh timer hardware failed failed to pass the Refresh Retrace Test. Interrupt Controller-1 BIOS POST could not initialize the Master Interrupt error Controller. This may indicate a problem with system hardware. Interrupt Controller-2 BIOS POST could not initialize the Slave Interrupt error Controller. This may indicate a problem with system hardware. PCI IRQ conflict
233
User Guide
www.nec-computers.com
The CMOS Date and/or Time are invalid. This error can be resolved by readjusting the system time in AMIBIOS Setup. CMOS Battery is low. This message usually indicates that the CMOS battery needs to be replaced. It could also appear when the user intentionally discharges the CMOS battery. CMOS settings are invalid. This error can be resolved by using AMIBIOS Setup. CMOS contents failed the Checksum check. Indicates that the CMOS data has been changed by a program other than the BIOS or that the CMOS is not retaining its data due to malfunction. This error can typically be resolved by using AMIBIOS Setup.
KBC BAT Test failed Keyboard controller BAT test failed. This may indicate a problem with keyboard controller initialization. Keyboard Error Keyboard is not present or the hardware is not responding when the keyboard controller is initialized. PS2 Keyboard not PS2 Keyboard support is enabled in the BIOS setup found but the device is not detected. PS2 Mouse not found PS2 Mouse support is enabled in the BIOS setup but the device is not detected. Keyboard/Interface Keyboard Controller failure. This may indicate a Error problem with system hardware. Unlock Keyboard PS2 keyboard is locked. User needs to unlock the keyboard to continue the BIOS POST. System Halted The system has been halted. A reset or power cycle is required to reboot the machine. This message appears after a fatal error has been detected. Indicates that <INS> key is pressed during the BIOS POST. The POST will load and use default CMOS settings.
<INS> Pressed
234
User Guide
www.nec-computers.com
Password check failed Unknown BIOS error. Error code = 004Ah Unknown BIOS error. Error code = 004Bh Floppy Controller Failure
The password entered does not match the password set in the setup. This condition may occur for both Supervisor and User password verification. This message is displayed when ADM module is not present in the AMIBIOS8 ROM. This message is displayed when language module is not present in the AMIBIOS8 ROM. Error in initializing legacy Floppy Controller.
Warning! Unsupported USB device found and disabled! Warning! Port 60h/ 64h emulation is not supported by this USB Host Controller! Warning! EHCI controller disabled. It requires 64bit data support in the BIOS.
This message is displayed when a non-bootable USB device is enumerated and disabled by the BIOS. This message is displayed to indicate that port 60h/ 64h emulation mode cannot be enabled for this USB host controller. This condition occurs if USB KBC emulation option is set for non-SMI mode. This message is displayed to indicate that EHCI controller is disabled because of incorrect data structure. This condition occur if the USB host controller needs 64-bit data structure while the USB is ported with 32bit data structure.
Not enough space in Runtime area!!. SMBIOS data will not be available.
This message is displayed when the size of the SMBIOS data exceeds the available SMBIOS runtime storage size.
235
User Guide
www.nec-computers.com
Warning! This sysThis message is displayed when the power requiretem board does not ments of the board do not match the power requiresupport the power ment of the CPU. requirements of the installed processor. The processor will be run at a reduced frequency, which will impact system performance.
236
User Guide
www.nec-computers.com
Restrictions
Caution
This document describes the restrictions on Express5800 120Rf1. Please read below notices carefully and make sure to follow them.
Note: If you have any questions about this document, please contact your sales representative.
237
User Guide
www.nec-computers.com
Use
Use this menu for basic system configuration. Use this menu to set the boot sequence and various on boot options. Use this menu to set the CPU, the drives, the super IO and the remote access configurations. Use this menu to configure the oboard devices and the advanced chipset . Use this menu to configure the power management settings. Use this menu to specify hardware monitoring values. Use this menu to set passwords. Loads the optimal default settings. Loads the failsafe default settings. Saves the changes and exist the BIOS Setup utility. Discards the changes just made and exits the BIOS Setup utility.
Use the arrow keys to select a menu or an item on a displayed menu. Press the value keys (listed in the table below) to cycle through the allowable values for the selected field. Use the Exit menus Save Values selection to save the current values on all the menus. To display a submenu, position the cursor on a selection that has a submenu and press ENTER. An arrow precedes selections with submenus.
238
User Guide
www.nec-computers.com
Refer to the following table for information on the keys that you use with BIOS Setup. These keys are also listed at the bottom of the Setup menu. Table 32: BIOS Setup Keys
Key F1 or Alt-H ESC Left or right arrow keys Up or down arrow keys F7 F9 F10 ENTER Function in Setup Menu Get Help about an item. Exit the current menu and return to the previous menu. Move between menus. Move cursor up and down. The cursor moves only to the settings that you can change. Load the previous values. Load default configuration values. Save configuration values and exit. Execute command or Select submenu.
239
User Guide
www.nec-computers.com
Description
Your Setting
Note: The BIOS may display more options that presented here.
240
User Guide
www.nec-computers.com
Description
Your Setting
Hard Disk Drives Submenu Specifies the boot sequence of the available devices. Removable Drives Submenu Specifies the boot sequence of the available devices. CD/DVD Drives Submenu Specifies the boot sequence of the available devices.
241
User Guide
www.nec-computers.com
Description
Press Enter to open the submenu Press Enter to open the submenu Press Enter to open the submenu Press Enter to open the submenu Press Enter to open the submenu
Your Setting
Advanced CPU Settings Submenu Table 36: Advanced CPU Settings Submenu
Feature
Manufacturer Brand String Frequency FSB Speed Cache L1 Cache L2 Ratio Status Ratio Actual Value Ratio CMOS Setting [16] Sets the ration between the CPU Core Clock and the FSB frequency. Only if Pentium 4 CPU. Enables or disables the HyperThreading technology. See note below. When set to Enabled, allows to boot a legacy OS that does not support CPUs with extended CPUID functions. When set to Disabled, forces the XD feature flag to always return to 0. Enables/Disables the Enhanced Hat State. When set to TM1, enables the CPU Thermal Monitor mechanism. Display Only Displays the relevant information
Description
Your Setting
C1E Support
Enabled Disabled
CPU TM Function
[TM1] Disabled
Notes: 1. This motherboard supports Intel Pentium 4 CPUs with Hyper-Threading Technology
242
User Guide
www.nec-computers.com
2. Hyper-Threading Technology is supported under Windows 2003, Windows XP and Linux 2.4x (kernel) and later versions only. Under Linux, use the Hyper-Threading compiler to compile code. If you are using any other operating system, disable the Hyper-Threading Technology in this submenu to ensure system stability and performance. 3. It is recommended that you install Windows XP Service Pack 1. 4. Make sure to enable the Hyper-Threading Technology in BIOS before installing a supported operating system. For more information on Hyper-Threading Technology, visit www.intel.com/info/hyperthreading.
243
User Guide
www.nec-computers.com
Description
Sets the type of floppy disk drive connected to the system.
Your Setting
Description
Specifies the ATA/IDE configuration.
Your Setting
Configure SATA as
ATAPI CDROM
Not Detected
Disabled Enabled
Enables/Disables the device write protection. This is effective only if the device is accessed through the BIOS. Sets the time out value for detecting ATA/ATAPI devices (in seconds). Sets the mechanism for detecting 80-pin ATA(PI) cable.
35 0 - 5 - 10 - 15 - 20 25 - 30
Description
Enables or disables the floppy controller. Sets the Serial Port 1 base address.
Your Setting
244
User Guide
www.nec-computers.com
Description
Sets the IR Port IRQ, or disables the IR Port.
Your Setting
Sets the ECP mode channel for the parallel port mode set to ECP. Sets the parallel port IRQ.
IRQ7 IRQ5
Remote Access Configuration Submenu Table 40: Remote Access Configuration Submenu
Feature
Remote Access
Description
Sets the Remote Access type.
Your Setting
245
User Guide
www.nec-computers.com
Description
Your Setting
Advanced Chipset Settings DRAM Frequency Sets the DRAM frequency. When set to Auto, the frequency is automatically detected.
246
User Guide
www.nec-computers.com
Description
Sets the ACPI state used for system suspend.
Your Setting
Power Management/APM Repost Video on S3 Resume P/S2 Keyboard Wakeup P/S2 Mouse Wakeup Suspend Time Out
Enabled Disabled No Yes Disabled Enables/disables VGA BIOS post on S3/STR resume.
Disabled
Disabled 1- 2 - 4 - 8 - 10 - 20 30 - 40 - 50 - 60 min
Goes into Suspend mode after the specified amount of time. When set to Disabled, does not enter the Suspend mode automatically. Specifies what happens when the power button is pressed; the system either turns on (or goes off) or enters Suspend mode. This option allows you to select how the system will react following a loss of power. Last State means that the system will be restored to the state which it was in previous to the power loss. Power Off means that you will have to restart your system with the power on button and Power On means the system will reboot itself automatically.
On/off Suspend
Resume on Ring
Disabled Enabled
Resume on PME#
Enabled Disabled Specifies whether these events can wake up the system from Suspend mode.
247
User Guide
www.nec-computers.com
Description
Displays or not a message during POST if the chassis has been opened. Specifies the temperature which triggers a shutdown.
Your Setting
Shutdown Temperature
System Temperature CPU Temperature System1 Temperature Rear Fan Speed CPU Fan Speed Front Fan Speed CPU Vcore +12V +1.5V +5V +3.3V SB VBAT Rear Fan Mode Setting
Display only Display only Display only Display only Display only Display only Display only Display only Display only Display only Display only Display only Smart FAN1 Mode Manual Mode
03 min = 0, max = 15
CPUFAN2 Tmin
248
User Guide
www.nec-computers.com
Description
Your Setting
249
User Guide
www.nec-computers.com
Description
Indicates whether the supervisor password is set (display only). Indicates whether the user password is set (view only). Press Enter to display the supervisor password entry screen. With the supervisor password, all SETUP menus are available for access. This option is available only when you log into the SETUP utility with the supervisor password. Press Enter to display the user password entry screen. With a user password, only certain menus are accessible. This option is available only if the Supervisor Password is set. Press Enter to display the supervisor password entry screen. With the supervisor password, all SETUP menus are available for access. This option is available only when you log into the SETUP utility with the supervisor password.
Your Setting
Up to 7 alphanumeric characters
Up to 7 alphanumeric characters
Up to 7 alphanumeric characters
Disabled Enabled
250
User Guide
www.nec-computers.com
Description
Load default values for all SETUP items. F9 key can be used for this operation.
Load failsafe values for all SETUP items. F8 key can be used for this operation.
Exit after writing all modified Setup item values to NVRAM. F10 key can be used for this operation.
251
User Guide
www.nec-computers.com
Updating BIOS
The AFU400 flash feature allows you to easily update the BIOS. To update the BIOS, proceed as follows: 1. Consult our Web site at the following address: http://www.neccomputers.com to download the latest BIOS file for your motherboard as weel as the AFU400 flashing utility (these files may have been zipped for your convenience). Save these files on a bootable floppy disk (unzip them if necessary). 2. Insert the floppy disk in the floppy disk drive, and reboot the system. 3. When the command prompt A:\ appears, type a dir command. 4. Depending on the contents of the directory: If there is a batch file (*.bat), launch this file. If there is only an afu400.exe file, type the following line to execute the file (these are default settings): afu400 filename.rom /p /b /n /c (replace filename with the actual name of the rom file you downloaded)
Note: For more explanations on the available parameters, check the help file.
Caution
Do not shutdown or reset the system while updating the BIOS! Doing so may cause system boot failure!
6. The following message should appear: CMOS Checksum Bad. Press F1 to Run Setup. When it does appear, press F1 to enter the BIOS Setup utility. 7. In the BIOS Setup utility, press F9 to load the setup defaults. 8. Press F10 to save the changes and exit the BIOS Setup utility.
252
User Guide
www.nec-computers.com
253
User Guide
www.nec-computers.com
Equipment Log
Use this equipment log form to record pertinent information about your system. You will need some of this information to run the System Setup Utility. Be sure to update the equipment log when you add options. Record the model and serial numbers of the system components, dates of component removal or replacement, and the name of the vendor from whom the component was purchased. Be sure to record the same information for any components added to the system, such as a power supply, hard disk drives, add-in boards, or printers. Record the model and serial numbers of the unit and system board. The model and serial numbers of the system unit are recorded on a label attached to the rear of the unit. The location of serial numbers on add-in boards, hard disk drives, and external equipment, such as video displays or printers, varies from one manufacturer to another. Literature accompanying these products should illustrate or describe the location of model and serial numbers.
254
User Guide
www.nec-computers.com
Hardware
Main Unit Model name CPU #1 Clock Clock Memory #7, #8 #5, #6 #3, #4 #1, #2 Monitor Type Model name Serial No. Date installed Hot-swap HDD cage Model name Serial No. Date installed Hot-swap SCSI Hard Disks ID0 Type Capacity Type number ID1 Type Capacity Type number ID2 Type Capacity Type number Fixed SCSI Hard Disks ID0 Type Capacity Type number ID1 Type Capacity Type number ID2 Type Capacity Serial No. Date installed Serial No. Date installed Serial No. Date installed Serial No. Date installed Serial No. Date installed Serial No. Date installed Size Size Size Size Serial No. Serial No. Serial No. Serial No. Date installed Date installed Date installed Date installed Serial No. Serial No. Date installed Date installed Serial No. Date installed
255
User Guide
www.nec-computers.com
Type number ID3 Type Capacity Type number Hot-swap SATA Hard Disks #1 Type Capacity Type number #2 Type Capacity Type number #3 Type Capacity Type number Hot-swap SATA Hard Disks #1 Type Capacity Type number #2 Type Capacity Type number #3 Type Capacity Type number #4 Type Capacity Type number 5.25-inch Device #1 Size Model name 5.25-inch Device #2 Size Model name 5.25-inch Device #3 Size Model name Capacity Type number Serial No. Date installed Capacity Type number Serial No. Date installed Capacity Type number Serial No. Date installed Serial No. Date installed Serial No. Date installed Serial No. Date installed Serial No. Date installed Serial No. Date installed Serial No. Date installed Serial No. Date installed Serial No. Date installed
256
User Guide
www.nec-computers.com
5.25-inch Device #4 Size Model name PCI Slot #1 Model name Serial No. Date installed PCI Slot #2 Model name Serial No. Date installed PCI Slot #3 Model name Serial No. Date installed PCI-E 1x Slot Model name Serial No. Date installed PCI-E 4x Slot Model name Serial No. Date installed PCI-E 16x Slot Model name Serial No. Date installed Printer Model name Manufacturer External USB Device 1 Model name Manufacturer External USB Device 2 Model name Manufacturer External USB Device 3 Model name Manufacturer External USB Device 4 Model name Manufacturer Serial No. Date installed Serial No. Date installed Serial No. Date installed Serial No. Date installed Serial No. Date installed Capacity Type number Serial No. Date installed
257
User Guide
www.nec-computers.com
External USB Device 5 Model name Manufacturer External USB Device 6 Model name Manufacturer External Parallel Device 1 Model name Manufacturer External IEEE Device 1 Model name Manufacturer External Serial Device 1 Model name Manufacturer Serial No. Date installed Serial No. Date installed Serial No. Date installed Serial No. Date installed Serial No. Date installed
258
User Guide
www.nec-computers.com
Software
Firmware version OS Application of RUR media File system FAT Others ( Bundled software installed Licensed software installed Application running when a failure occurred Apply Name: Name: HPFS NTFS ) Version Version
259
User Guide
www.nec-computers.com
Specifications
Table 46: TM800 Specifications
Item
Cabinet design Chipset CPU Type L2 Cache HyperTransport Bus Number of processors Packaging Frequency Memory Minimum Maximum Connectors Memory module Error check Floppy Disk Drive Hard Disk Drive Technology
Description
Tower or Rack (with conversion optional kit) i955X + ICH7R Intel(R) Pentium(R) 4 2 MB 800 MHz 1 (max: 1) Socket FC-LGA775 2.8 GHz minimum 256 MB 4 GB (4x1GB) 4 slots DDR2 533 ECC 3.5-inch drive 1 SCSI S-ATA 2.8 GHz minimum 2.8 to 3.2 GHz Intel(R) Celeron(R) D 256 KB 533 MHz Intel(R) Pentium(R) D 2 x 1MB 800 MHz
RPM Socket
10000 rpm Non hot-swap: 68pins Hot-swap: 80pins RAID 0, RAID1, RAID 10 and RAID 5 (with optional adapter board)
7200 rpm _
RAID
RAID 0, RAID1, RAID 10 and RAID 5 (with onboard chipset or optional adapter board)
5.25-inch bay 3.5-inch bay Non Hot-swap Hot-swap Keyboard Mouse USB Serial Network Parallel Audio
4 slots 1 slot 4 slots 3 slots PS/2 (1 port) PS/2 (1 port) 2.0 (6 ports - 2 on the front, 4 on the rear) FIFO compatible (1 port) RJ-45 (2 ports) SPP (Standard Parallel Port)/ EPP (Enhanced Parallel Port) / ECP (Extended Capabilities Port) support (1 port) Microphone in (2 ports - 1 on the front, 1 on the rear) Stereo line in (1 port) Stereo line out (2 ports - 1 on the front, 1 on the rear) IEEE 1394 (2 ports - 1 mini on the rear, 1 normal on the front)
IEEE
260
User Guide
www.nec-computers.com
Description
32-bit/33MHz (3 slots) 1 slot 1 slot 1 slot Realtek 1GB 8118/8110 family Integrated 10/100/1000 transceiver Supports PCI v2.3, 32-bit, 33/ 66MHz Supports PCI Express architecture (v1.0a) Supports Active Management Technology (AMT) Supports IEEE 802.3, IEEE 802.3u, IEEE 802.3ab IntelPRO 1000M
PCI-E x16 support ISA Flash ROM 4 MB Power On Self Test (POST) 425 (height) 198 (width) mm 465 (depth) 14 kg Input voltages 220 to 240 VA Input voltages 110 to 220 VA
External dimensions Weight Power supply (depending on your configuration) Power consumption (maximum)
Temperature Humidity
261
User Guide
www.nec-computers.com
262
User Guide
www.nec-computers.com
Index
Numerics 3.5-inch bay ............................................. 17 5.25-inch Bay .................................................... 17 Device .............................................. 117 A AC Power Connector .............................. 18 ACPI ........................................................ 26 Advanced BIOS Features Menu ............ 242 Advanced Chipset Features Menu ......... 246 B Backup Copies ....................................... 193 Batteries ................................................... 13 Disposing of ...................................... 13 Replacing ........................................... 13 Battery ................................................... 131 Bays 3.5-inch .............................................. 17 5.25 inch ............................................ 17 BIOS Revision Level ............................ 253 BIOS Security Features Menu ............... 250 BIOS Setup Utility ................................ 238 Boot Configuration Features Menu ....... 241 C Cable IDE .................................................. 138 S-ATA ............................................. 142 System Power .......................... 139, 142 CD-ROM Drive ....................................... 30 CE marking ............................................. 11 Cleaning ................................................ 194 Combination Drive .................................. 32 Configuring MotherBoard Jumpers ....................... 23 Connecting Power Cord ........................................ 74 D Disk Access Lamp ................................... 20 DVD-ROM Drive .................................... 31
E Equipment Log .............................. 112, 254 Error Codes POST ............................................... 228 Error Messages POST ............................................... 228 Exit Menu .............................................. 251 Expansion Board Slots ............................ 19 Expansion Card ..................................... 132 F Features Optional Features .............................. 29 Standard Features .............................. 25 Floppy Disk Drive ................................. 119 Front Panel ............................................ 116 Front View .............................................. 17 H Hard Disk Drive .................................... 120 HDD Slots ......................................... 21 S-ATA HDD ..................................... 43 S-ATA HDD Cage ............................ 43 SCSI HDD ........................................ 44 SCSI HDD Cage ............................... 44 Hard Disk Drive Cage ........................... 123 SCSI ................................................ 125 Hardware Health Configure Menu ........ 248 I IDE Device Lamp ................................... 17 Intel Matrix Storage Manager (Windows Interface) .................................................. 168 Interrupt Requests ................................. 149 K Keyboard ................................................. 27 L Lamp Disk Access ....................................... 20 IDE Device ........................................ 17 LAN Connector ................................. 20 Power ................................................ 20 Status ................................................. 17 LAN Board Intel Pro 1000 MT ............................. 41 PCI-E x1 Syskonnect ........................ 42 LAN Connector Lamp ............................ 20
263
User Guide
www.nec-computers.com
M Memory ................................................... 25 RAM ................................................ 129 Motherboard ...................................... 21, 22 MotherBoard Jumpers Configuring ....................................... 23 Mouse ...................................................... 27 N Network Controller ................................. 26 P Passwords .............................................. 189 PCI Slots .................................................. 25 PCI-Express Slot ..................................... 25 Ports USB ................................................... 17 POST Error Codes ..................................... 228 Error Messages ................................ 228 Power Button ................................................ 17 Forced Power Off .............................. 79 Off ..................................................... 78 On ...................................................... 76 Power Cord Connecting ........................................ 74 Power Lamp ............................................ 20 Power Management Features Menu ...... 247 Power Supply .......................................... 21 Problem Solving ............ 202, 225, 226, 227 Problems After the System Has Been Running Correctly ........................................ 226 Problems and Suggestions ..................... 202 Problems at initial System Start-up ....... 225 Problems Running New Application Software ....................................................... 227 Processor ......................................... 25, 126 R Rack Installation Kit Assembly ............... 66 Rack-Mount subsystem assembly ........... 66 RAID ............................. 82, 86, 87, 92, 175 Configuring RAID ............................. 82 SATA Hard Disk Drives ....... 86, 87, 92 SCSI Hard Disk Drives ............. 95, 110 Rear View ................................................ 18 Regulatory information ........................... 14 Resetting .................................................. 80 Server ................................................ 80 Right Side Door ..................................... 114
S Safety Information ................................ 111 SATA RAID configuration .............. 86, 87, 92 SCSI RAID configuration .................. 95, 110 SCSISelect Utility ................................. 172 Security ................................................. 187 Server Resetting ........................................... 80 Specifications ........................................ 260 Standard BIOS Features Menu ............. 240 Static Precautions .................................. 112 Status Lamp ............................................ 17 System forcing a power shutdown ................. 79 Powering Off ..................................... 78 Powering On ..................................... 76 System Connectors .................................. 19 T Troubleshooting .................................... 200 Troubleshooting Guide ......................... 200 U Unpacking the Rack Mounting Hardware .. 66 USB ports ................................................ 17 V Video Board PCI .................................................... 54 PCI-E x16 .......................................... 46
264