6

EnCORE

PICTORIAL VIEW (SHEAR BLOCK ASSEMBLY)

COVER MULLION SHEAR BLOCK WATER DEFLECTOR (Standard Mullion Show SSG Optional) GLAZING CLIP HEAD SETTING BLOCK CHAIR INTERMEDIATE HORIZONTAL SILL

NOVEMBER, 2009

SILL FLASHING

EC 97911-15

kawneer.com Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Kawneer Company, Inc., 2009

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Kawneer Company, Inc., 2009

Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

kawneer.com

EC 97911-15

NOVEMBER, 2009

5/16" Dia. WEEP HOLE

COVER MULLION SPLINE SCREWS SHEAR BLOCK WATER DEFLECTOR SETTING BLOCK CHAIR GLAZING CLIP GLAZING CLIP SILL HEAD INTERMEDIATE HORIZONTAL

EnCORE
7

PICTORIAL VIEW (TYPE-B ASSEMBLY)

DETAILS

EnCORE

PICTORIAL VIEW (TYPE-B SSG ASSEMBLY)

SSG MULLION

SPLINE SCREWS SHEAR BLOCK COVER SETTING BLOCK CHAIR

GLAZING CLIP

GLAZING CLIP

SILL

HEAD

INTERMEDIATE HORIZONTAL

NOVEMBER, 2009 EC 97911-15

kawneer.com Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Kawneer Company, Inc., 2009

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Kawneer Company, Inc., 2009

Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

kawneer.com

EC 97911-15

NOVEMBER, 2009

SCALE 3" = 1'-0"

JAMB

1/4" INFILL

1 HEAD

HORIZONTAL

SILL

3 2
175-002 FLASHING

ELEVATION IS NUMBER KEYED TO DETAILS

MULLION 1 HEAD 2 HORIZONTAL 3 SILL


175-002 FLASHING
1-3/4" (44.5) TYP.

4 JAMB
175-171 ADAPTER

175-005

1" INFILL

175-155

3-9/16" SYSTEM (SCREW SPLINE)

5 SPLIT MULLION 2A HORIZONTAL W/ 1/4" ADAPTER

5/8" (15.9)

175-007

3-9/16" (90.5) TYP.

EnCORE

5A SPLIT MULLION W/ 1/4" ADAPTER

175-171 ADAPTER

10

SCALE 3" = 1'-0"

4 JAMB

EnCORE

1/4" INFILL

1 HEAD

2 HORIZONTAL

3 SILL

175-052 FLASHING

175-075

1-3/4" (44.5) TYP.

175-155

4-1/2" SYSTEM (SCREW SPLINE)

5 MULLION ELEVATION IS NUMBER KEYED TO DETAILS 1 HEAD 2 HORIZONTAL 3 SILL


1-3/4" (44.5) TYP.

5/8" (15.9)

175-077

4-1/2" (114.3) TYP.

4 JAMB
175-052 FLASHING
175-055

175-055

1" INFILL

175-155

5 SPLIT MULLION
175-171 ADAPTER

175-057

5/8" (15.9)

4-1/2" (114.3) TYP.

175-155

175-171 ADAPTER

2A HORIZONTAL W/ 1/4" ADAPTER

175-155

175-050

1 HEAD w/ caulk leg

5A SPLIT MULLION W/ 1/4" ADAPTER

NOVEMBER, 2009

EC 97911-15

175-057

kawneer.com

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Kawneer Company, Inc., 2009

Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Kawneer Company, Inc., 2009

Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

kawneer.com

EC 97911-15

NOVEMBER, 2009

SCALE 3" = 1'-0"

4 JAMB

1/4" INFILL

1 HEAD

2 HORIZONTAL

3 SILL
175-002 FLASHING

ELEVATION IS NUMBER KEYED TO DETAILS

5 MULLION 1 HEAD 2 HORIZONTAL 3 SILL

4-1/2" SYSTEM - CENTER GLAZED (SCREW SPLINE)

4 JAMB
175-002 FLASHING
175-156

1" INFILL

5 SPLIT MULLION 2A HORIZONTAL W/ 1/4" ADAPTER

EnCORE

175-171 ADAPTER

175-171 ADAPTER

175-003

5A SPLIT MULLION W/ 1/4" ADAPTER

11

12

SCALE 3" = 1'-0"

4 JAMB

EnCORE

1/4" INFILL

1 HEAD

2 HORIZONTAL

3 SILL
175-125

1-3/4" (44.5) TYP.

175-155
175-102 FLASHING

6" SYSTEM (SCREW SPLINE)

5 MULLION 1 HEAD ELEVATION IS NUMBER KEYED TO DETAILS 2 HORIZONTAL 3 SILL


175-105
1-3/4" (44.5) TYP.

5/8" (15.9)

175-127

6" (152.4) TYP.

4 JAMB
175-102 FLASHING
175-107

1" INFILL

175-155

5 SPLIT MULLION
175-171 ADAPTER
175-105

5/8" (15.9)

175-155

6" (152.4) TYP.

175-171 ADAPTER

2A HORIZONTAL W/ 1/4" ADAPTER

175-155

1 HEAD w/ caulk leg

5A SPLIT MULLION W/ 1/4" ADAPTER


175-107

NOVEMBER, 2009

EC 97911-15

175-100

kawneer.com

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Kawneer Company, Inc., 2009

Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Kawneer Company, Inc., 2009

Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

kawneer.com

EC 97911-15

NOVEMBER, 2009

SCALE 3" = 1'-0"

4 JAMB 1 HEAD 3 SILL

1/4" INFILL

2 HORIZONTAL

5 MULLION
175-002 FLASHING

ELEVATION IS NUMBER KEYED TO DETAILS

NOTE: TYPE-B SYSTEM SIMILAR EXCEPT HEAD & SILL RUN THROUGH.

6 SSG MULLION 1 HEAD 3 SILL

4 JAMB

6 ssg mullion
175-002 FLASHING 175-171 ADAPTER
175-003 175-155

1" INFILL

3-9/16" SYSTEM (SHEAR BLOCK)

6a w/ 1/4" adapter inside seal


175-171 ADAPTER

175-171 ADAPTER

5 MULLION

EnCORE

2 HORIZONTAL

2A HORIZONTAL W/ 1/4" ADAPTER

5A MULLION W/ 1/4" ADAPTER

6A W/ 1/4" ADAPTER outside seal

175-171 ADAPTER

13

14

SCALE 3" = 1'-0"

4 JAMB 1 HEAD 3 SILL

EnCORE

1/4" INFILL

2 HORIZONTAL

4-1/2" SYSTEM (SHEAR BLOCK)

5 MULLION
175-052 FLASHING

ELEVATION IS NUMBER KEYED TO DETAILS

NOTE: TYPE-B SYSTEM SIMILAR EXCEPT HEAD & SILL RUN THROUGH.

6 SSG MULLION 1 HEAD 3 SILL

4 JAMB

6 ssg mullion
175-052 FLASHING

1" INFILL

6a w/ 1/4" adapter inside seal 2A HORIZONTAL W/ 1/4" ADAPTER


175-171 ADAPTER 175-171 ADAPTER

175-171 ADAPTER

5 MULLION

2 HORIZONTAL

5A MULLION W/ 1/4" ADAPTER

NOVEMBER, 2009

6A W/ 1/4" ADAPTER outside seal

175-171 ADAPTER

EC 97911-15

kawneer.com

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Kawneer Company, Inc., 2009

Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Kawneer Company, Inc., 2009

Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

kawneer.com

EC 97911-15

NOVEMBER, 2009

SCALE 3" = 1'-0"

4 JAMB 1 HEAD 3 SILL

1/4" INFILL

2 HORIZONTAL

5 MULLION
175-002 FLASHING

ELEVATION IS NUMBER KEYED TO DETAILS

NOTE: TYPE-B SYSTEM SIMILAR EXCEPT HEAD & SILL RUN THROUGH.

6 SSG MULLION 1 HEAD 3 SILL

4 JAMB

4-1/2" SYSTEM - CENTER GLAZED (SHEAR BLOCK)

6 SSG MULLION
175-002 FLASHING

1" INFILL

6A W/ 1/4" ADAPTER INSIDE SEAL


175-171 ADAPTER 175-171 ADAPTER

175-171 ADAPTER

5 MULLION

EnCORE

2 HORIZONTAL

2A HORIZONTAL W/ 1/4" ADAPTER

5A MULLION W/ 1/4" ADAPTER

6A W/ 1/4" ADAPTER OUTSIDE SEAL

175-171 ADAPTER

15

16

SCALE 3" = 1'-0"

4 JAMB 1 HEAD 3 SILL

EnCORE

1/4" INFILL

6" SYSTEM (SHEAR BLOCK)

2 HORIZONTAL

5 MULLION
175-102 FLASHING

ELEVATION IS NUMBER KEYED TO DETAILS

NOTE: TYPE-B SYSTEM SIMILAR EXCEPT HEAD & SILL RUN THROUGH.

6 SSG MULLION 4 JAMB 1 HEAD 3 SILL


175-102 FLASHING

6 SSG MULLION 5 MULLION 2 HORIZONTAL 2A HORIZONTAL W/ 1/4" ADAPTER


175-171 ADAPTER

1" INFILL

6A W/ 1/4" ADAPTER INSIDE SEAL 5A MULLION W/ 1/4" ADAPTER


175-171 ADAPTER

175-171 ADAPTER

NOVEMBER, 2009

6A W/ 1/4" ADAPTER OUTSIDE SEAL

175-171 ADAPTER

EC 97911-15

kawneer.com

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Kawneer Company, Inc., 2009

Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Kawneer Company, Inc., 2009

Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

kawneer.com

EC 97911-15

NOVEMBER, 2009

SCALE 3" = 1'-0" 1/4" INFILL

3-9/16" SYSTEM

4-1/2" SYSTEM

4-1/2" SYSTEM center glazed

6" SYSTEM

90 OUTSIDE CORNERS

1" INFILL

EnCORE
17

18

SCALE 3" = 1'-0"


90 INSIDE CORNERS

EnCORE

1/4" INFILL

3-9/16" SYSTEM

4-1/2" SYSTEM

4-1/2" SYSTEM center glazed

6" SYSTEM

1" INFILL
NOVEMBER, 2009 EC 97911-15

kawneer.com Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Kawneer Company, Inc., 2009

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Kawneer Company, Inc., 2009

Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

kawneer.com

EC 97911-15

NOVEMBER, 2009

SCALE 3" = 1'-0" 1/4" INFILL

3-9/16" SYSTEM

4-1/2" SYSTEM

4-1/2" SYSTEM center glazed

6" SYSTEM

135 OUTSIDE CORNERS

1" INFILL

EnCORE
19

20

SCALE 3" = 1'-0"

5/8" (15.9) 175-079


175-155 1-3/4" (44.5)

EnCORE

4-1/2" (114.3)

135 INSIDE CORNERS

1/4" INFILL

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Kawneer Company, Inc., 2009

17 17 507 9

5-

15

3-9/16" SYSTEM

4-1/2" SYSTEM

4-1/2" SYSTEM center glazed

6" SYSTEM

1" INFILL
NOVEMBER, 2009 EC 97911-15

kawneer.com Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

NOVEMBER, 2009 EC 97911-15

EnCORE
MISCELLANEOUS FRAMING

21

SCALE 3" = 1'-0" 1-1/4" narrow perimeter


screw spline system with 1/4" infill

1-1/4" narrow perimeter


screw spline system with 1" infill

Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

3-9/16" SYSTEM

4-1/2" SYSTEM

4-1/2" SYSTEM center glazed

6" SYSTEM

head receptors

heavy mullions

(IN LIEU OF 175-003) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

3-9/16" non-thermal

3-9/16" thermal

(IN LIEU OF 175-053)

(IN LIEU OF 175-103)

Kawneer Company, Inc., 2009

4-1/2" non-thermal
279-504

4-1/2" thermal

(IN LIEU OF 175-005)

279-501

(IN LIEU OF 175-055)

6" non-thermal

6" thermal

(IN LIEU OF 175-105)

NOTE: HEAVY MULLIONS CAN BE USED WITH STANDARD FACE COVERS 175-155 & 175-156

kawneer.com

22

EnCORE
MISCELLANEOUS FRAMING / GLAZING CHART

NOVEMBER, 2009 EC 97911-15

SCALE 3" = 1'-0" HORIZONTAL / CROSSRAIL ASSEMBLY


(SCREW SPLINE SYSTEM)

1/4" INFILL

1" INFILL
Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. kawneer.com Kawneer Company, Inc., 2009

BRAKE METAL

BRAKE METAL

(SHOWN WITH 3-9/16" DEEP SYSTEM)

1/2" INFILL ADAPTER

EnCORE GLAZING CHART


INFILL THICKNESS 1/8" 1/4" ADAPTER for 1" Infill Pocket 175-171 175-171 175-171 175-173 175-173 175-175 WEATHERING (Both Sides) 027-077 Heavy 027-074 Standard 027-076 Light 027-074 Standard 027-076 Light 027-074 Standard 027-077 Heavy 027-074 Standard 027-076 Light

175-173 ADAPTER

3/8" 1/2" 5/8" 3/4" 7/8" 1"

HEAD
175-173 ADAPTER

HORIZONTAL

1-1/8"

175-173 ADAPTER

175-173 ADAPTER

NOTE: For infill thicknesses in 1/16" increments or oversize glass, use a combination of the Std. (027-074) with either the Light (27-076) or the Heavy (027-077) gaskets.

SSG GLAZING CHART


INFILL THICKNESS SSG ADAPTER 175-172 175-173 HORIZONTAL WEATHERING 027-074 Std. 027-074 Std. SSG WEATHERING 175-302 175-302

JAMB

MULLION

1/4" 1/2"

NOVEMBER, 2009 EC 97911-15

EnCORE
GLASSvent

23

SCALE 3" = 1'-0"

OUTSWING CASEMENT
Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

PROJECT-OUT
1
175-053

175-155

175-051

2 7

3
3 8 4

452-132

452-132

452-132

ELEVATION IS NUMBER KEYED TO DETAILS

452-132 175-051

175-053

175-155

175-155

175-052

OUTSWING CASEMENT
175-051 175-053 175-053

PROJECT-OUT
175-053

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

452-132 175-155

452-132

175-155

175-155

452-132

452-132

175-155

Kawneer Company, Inc., 2009

NOTE: Bronze spacer is recommended when 1" insulating glass is used.

MAXIMUM / MINIMUM SIZES (1" INFILL) PROJECT-OUT MAXIMUM 60" x 36" MINIMUM 14" x 14"

OUTSWING CASEMENT MAXIMUM 36" x 60" MINIMUM 14" x 14"

kawneer.com

24

EnCORE
GLASSvent

NOVEMBER, 2009 EC 97911-15

STOREFRONT GLASSvent HARDWARE SELECTION GUIDE


DESCRIPTION Stainless steel 4-bar hinge Cast white bronze cam lock Cast white bronze cam lock with pole ring Cast white bronze custodial lock with removable handle Cast white bronze concealed lock with removable hex key Cast white bronze pole/pull ring Pivot-shoe roto-operator Multi-point lock with cast white bronze locking handle Insect screen OPTIONAL PROJECT - OUT STANDARD STANDARD OPTIONAL OPTIONAL OPTIONAL OPTIONAL OPTIONAL OPTIONAL OPTIONAL OUTSWING CASEMENT STANDARD STANDARD OPTIONAL OPTIONAL OPTIONAL
Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. kawneer.com Kawneer Company, Inc., 2009

CAM LOCK

CAM LOCK WITH POLE RING

PULL RING

ACCESS CONTROL LOCK

REMOVABLE HANDLE

PIVOT-SHOE ROTO-OPERATOR

STAINLESS STEEL 4 BAR HINGES

CONCEALED LOCK

INSECT SCREEN WITH STANDARD WICKET

INSECT SCREEN WITH FULL WICKET

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Kawneer Company, Inc., 2009

Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

kawneer.com

EC 97911-15

NOVEMBER, 2009

SCALE 3" = 1'-0"

175-174 VENT ADAPTER 175-174 VENT ADAPTER

3
175-174 VENT ADAPTER 175-174 VENT ADAPTER

8225TL PROJECT-OUT VENT SHOWN

NOTE: Other vent types can be accommodated. Consult your Kawneer Representative for other options.

ELEVATION IS NUMBER KEYED TO DETAILS

2 4

EnCORE
VENTS

25

26

EnCORE
4-1/2" ENTRANCE FRAMING (FRONT GLAZED)

NOVEMBER, 2009 EC 97911-15

SCALE 3" = 1'-0"

EnCORE FRAMING INCORPORATING KAWNEER "190" DOORS. NOTE: Other types of Kawneer doors may be used with this framing. See the Entrance Section for additional information.
Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. kawneer.com Kawneer Company, Inc., 2009

1 TRANSOM HEAD

ELEVATION IS NUMBER KEYED TO DETAILS

175-251 STOPS

175-251 STOPS

175-251 STOPS

450-500 TRAY

2 OFFSET PIVOT/ BUTT HUNG TRANSOM BAR

2 S/A OFFSET ARM OFFSET PIVOT/ BUTT HUNG TRANSOM BAR

2 C.O.C. CENTER PIVOT TRANSOM BAR

450-500 TRAY

3 OFFSET PIVOT/ BUTT HUNG HEADER

3 S/A OFFSET ARM OFFSET PIVOT/ BUTT HUNG HEADER

3 C.O.C. CENTER PIVOT HEADER

NOVEMBER, 2009 EC 97911-15

EnCORE
4-1/2" ENTRANCE FRAMING (FRONT GLAZED)

27

SCALE 3" = 1'-0"


Transom area for both double or single acting doors with glass surround. Jambs above transom area are routed out to accept pocket insert 175-253.
Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

175-253 POCKET INSERT

4 DOOR JAMB AT TRANSOM

4 DOOR JAMB AT TRANSOM (OPTIONAL)

5 SINGLE ACTING SSG DOOR JAMB W/ DOOR ADAPTER

5 DOUBLE ACTING SSG DOOR JAMB W/ DOOR ADAPTER

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

5 SINGLE ACTING DOOR JAMB

5 DOUBLE ACTING DOOR JAMB

5 SINGLE ACTING DOOR JAMB W/ DOOR ADAPTER

5 DOUBLE ACTING DOOR JAMB W/ DOOR ADAPTER

Kawneer Company, Inc., 2009

HOLE PLUG

HOLE PLUG

6 SINGLE ACTING DOOR JAMB

6 DOUBLE ACTING DOOR JAMB

6 SINGLE ACTING DOOR JAMB W/ DOOR ADAPTER

6 DOUBLE ACTING DOOR JAMB W/ DOOR ADAPTER

kawneer.com

28

EnCORE
4-1/2" ENTRANCE FRAMING (CENTER GLAZED)

NOVEMBER, 2009 EC 97911-15

SCALE 3" = 1'-0"

EnCORE FRAMING INCORPORATING KAWNEER "190" DOORS. NOTE: Other types of Kawneer doors may be used with this framing. See the Entrance Section for additional information.
Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. kawneer.com Kawneer Company, Inc., 2009

1 TRANSOM HEAD

ELEVATION IS NUMBER KEYED TO DETAILS

175-252 STOP

175-251 STOP

175-252 STOP

175-251 STOP

175-252 STOP

175-251 STOP

450-500 TRAY

2 OFFSET PIVOT/ BUTT HUNG TRANSOM BAR

2 S/A OFFSET ARM OFFSET PIVOT/ BUTT HUNG TRANSOM BAR

2 C.O.C. CENTER PIVOT TRANSOM BAR

450-500 TRAY

3 OFFSET PIVOT/ BUTT HUNG HEADER

3 S/A OFFSET ARM OFFSET PIVOT/ BUTT HUNG HEADER

3 C.O.C. CENTER PIVOT HEADER

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Kawneer Company, Inc., 2009

Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

kawneer.com

EC 97911-15

NOVEMBER, 2009

SCALE 3" = 1'-0"

5 SINGLE ACTING DOOR JAMB

Transom area for both double or single acting doors with glass surround. Jambs above transom area are routed out to accept pocket insert 175-253.

6 SINGLE ACTING DOOR JAMB 4 DOOR JAMB AT TRANSOM


175-253 POCKET INSERT

175-231 or 175-641

5 DOUBLE ACTING DOOR JAMB

4-1/2" ENTRANCE FRAMING (CENTER GLAZED)

6 DOUBLE ACTING DOOR JAMB

EnCORE
29

30

EnCORE
6" ENTRANCE FRAMING (FRONT GLAZED)

NOVEMBER, 2009 EC 97911-15

SCALE 3" = 1'-0"

EnCORE FRAMING INCORPORATING KAWNEER "190" DOORS. NOTE: Other types of Kawneer doors may be used with this framing. See the Entrance Section for additional information.
Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. kawneer.com 450-500 TRAY Kawneer Company, Inc., 2009

1 TRANSOM HEAD

ELEVATION IS NUMBER KEYED TO DETAILS

175-251 STOPS

175-251 STOPS

175-251 STOPS

450-500 TRAY

2 OFFSET PIVOT/ BUTT HUNG TRANSOM BAR

2 S/A OFFSET ARM OFFSET PIVOT/ BUTT HUNG TRANSOM BAR

2 C.O.C. CENTER PIVOT TRANSOM BAR

3 OFFSET PIVOT/ BUTT HUNG HEADER

3 S/A OFFSET ARM OFFSET PIVOT/ BUTT HUNG HEADER

3 C.O.C. CENTER PIVOT HEADER

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Kawneer Company, Inc., 2009

Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

kawneer.com

EC 97911-15

NOVEMBER, 2009

SCALE 3" = 1'-0"

4 DOOR JAMB AT TRANSOM

175-164 175-101

5 SINGLE ACTING SSG DOOR JAMB W/ DOOR ADAPTER

5 SINGLE ACTING DOOR JAMB W/ DOOR ADAPTER

175-643 175-101

6 SINGLE ACTING DOOR JAMB W/ DOOR ADAPTER 5 DOUBLE ACTING DOOR JAMB W/ DOOR ADAPTER

HOLE PLUG

175-164

EnCORE

6" ENTRANCE FRAMING (FRONT GLAZED)

175-233

6 DOUBLE ACTING DOOR JAMB W/ DOOR ADAPTER

5 DOUBLE ACTING SSG DOOR JAMB W/ DOOR ADAPTER

HOLE PLUG

31

32

EnCORE
ENTRANCE FRAMING OPTIONS

NOVEMBER, 2009 EC 97911-15

SCALE 3" = 1'-0"

COMMON DOOR JAMBS

SINGLE ACTING DOOR JAMB

DOUBLE ACTING DOOR JAMB

HOLE PLUG

HOLE PLUG

SINGLE ACTING DOOR JAMB W/ DOOR ADAPTER

DOUBLE ACTING DOOR JAMB W/ DOOR ADAPTER

SINGLE ACTING SSG DOOR JAMB W/ DOOR ADAPTER

175-103

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. kawneer.com

HOLE PLUG

175-234

HOLE PLUG

SINGLE ACTING DOOR JAMB W/ DOOR ADAPTER

DOUBLE ACTING DOOR JAMB W/ DOOR ADAPTER

SINGLE ACTING SSG DOOR JAMB W/ DOOR ADAPTER

Kawneer Company, Inc., 2009

Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

MISCELLANEOUS FRAMING
SAFETY RAILS

OCTOBER, 2010 EC-97911-22

SCALE 3" = 1'-0"

RAILING MOUNTED ON FACE OF MULLION


1-1/4" (31.8)

RAILING MOUNTED BETWEEN MULLIONS

104-060 SAFETY RAIL

060-274 STAND OFF ANCHOR BAR

060-275 STANDARD END CAP

060-276 BETWEEN MULLION END CAP

060-274 STAND OFF ANCHOR BAR

MULLION

104-060 SAFETY RAIL

DETAIL OF AREA AFTER ASSEMBLY

060-275 STANDARD END CAP

060-276 BETWEEN MULLION END CAP

RAILING MOUNTED ON FACE OF MULLION

RAILING MOUNTED BETWEEN MULLIONS

kawneer.com

Kawneer Company, Inc., 2010

MULLION

104-060 SAFETY RAIL

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

6" (152.4)

350 IR ENTRANCES
SCALE 3" = 1'-0"
IR 500 ENTRANCE FRAMING DETAILS Hurricane Resistant Product

MAY, 2012 EC 97911-43

NOTE: 1. IR 500 FRAMING WITH 9/16" (14.3) GLAZING IS DETAILED WITH THESE DOORS FOR REFERENCE. OTHER GLAZING INFILLS MAY BE USED WITH THE IR 500 SERIES FRAMING. SEE CATALOG SECTION IR 500/501 FRAMING FOR APPROPRIATE DETAILS.
1 7 2 8 7 1 2
Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Kawneer Company, Inc., 2012

2-1/2" (63.5)

575-012

1 TRANSOM HEAD
5" (127)

ELEVATION IS NUMBER KEYED TO DETAILS

575-051 575-033

575-051

575-004

575-022

575-035

575-035

2-1/2" (63.5)

1-1/8" (28.6)

1-1/8" (28.6)

2-1/2" (63.5)

7* DOOR JAMB AT TRANSOM


575-051

8* DOOR JAMB AT TRANSOM


575-051

3-1/2" (88.9)

2-1/2" 1/8" (63.5) (3.2)

575-033

2 DOOR WITH TRANSOM

575-035

575-035

3/32" (2.4) 2-1/2" (63.5)

3-1/2" (88.9)

3-1/2" (88.9)

3/32" (2.4) 2-1/2" (63.5)

4 DOOR JAMB

6 DOOR JAMB

6-1/2" (165.1)

200-795

069-139

11/16" (17.5)
3-1/2" (88.9) 1/8" (3.2)

3 THRESHOLD

5 PAIR OF DOORS

3-1/2" (88.9)

* STEEL REINFORCING AS REQUIRED.

kawneer.com