Anda di halaman 1dari 3

CONDUIT

02/09/2008 Conduit Very Flexible - Medium Fatigue Construction PVCu Spiral with plasticised covering

Technical Data Sheet

Page No.1

INSERT PICTURE HERE

Non-Metallic Systems TYPE XF -XTRAFLEX


Applications
Torsional Equipment

Fittings IP65

Xtraflex Fittings

Characteristics High UV Resistance


Very High Flexibility Medium Fatigue life Self Extinguishing Electrical Insulator Smooth bore

Approvals CE LVD

Material

PVCu Spiral with plasticised covering

Part No.

Conduit Size
NC Inside Diameter 10.0 12.0 16.0 22.0 28.0 38.0 50.0

Dimensions
Outside Diameter Reel Length 14.5 16.5 20.5 27.5 33.5 44.0 57.5 30 30 30 30 30 30 30 (C) Min Bend Radius 25 30 35 50 60 80 105 Colour BL BL BL BL BL BL BL

XF12 XF16 XF20 XF25 XF32 XF40 XF50

12 16 20 25 32 40 50

Adaptaflex, Station Road, Coleshill, B46 1HT United Kingdom - Tel: +44(0)1675 468222 - Fax: +44(0)1675 464930 - e-mail: sales@adaptaflex.co.uk - www.adaptaflex.com

CONDUIT

02/09/2008 Conduit Very Flexible - Medium Fatigue Construction PVCu Spiral with plasticised covering

Technical Data Sheet

Page No.2

INSERT PICTURE HERE

Non-Metallic Systems TYPE XF -XTRAFLEX


Properties
Test Type Dynamic Static Flammability Electrical resistance Method/Standards UL94 Suitable Value -5 OC to +60 OC -20 OC to +60 OC Self Extinguishing >100M Limited Suitability

Chemical Properties
Astm No.1 Astm No.2 Astm No.3 Acetic Acid (10%) Acetone Aluminium Chloride Aniline Benzaldehyde Benzene Carbon tetrachloride Chlorine water Chloroform Citric Acid Copper Sulphate Cresol Diesel oil Diethylamine Ethanol Ether Ethylamine Ethylene Glycol Ethyl Ethanoate Freon 32 Hydrochloric Acid (10%) Hydrochloric Acid (36%) Hydrogen Peroxide (35%) Hydrogen Peroxide (87%) Lactic Acid Lubricating oil

Not Suitable Not Suitable Not Suitable Not Suitable Not Suitable Not Suitable Not Suitable Not Suitable Not Suitable

Methanol Methyl Bromide MEK Nitric Acid (10%) Nitric Acid (70%) Oxalic Acid Ozone (Gas) Paraffin oil Petrol Phenol Sea Water Silver Nitrate Skydrol Sodium Chloride Sodium Hydroxide (10%) Sodium Hydroxide (60%) Sulphur Dioxide (Gas)

Not Suitable Not Suitable Not Suitable

Not Suitable

Not Suitable

Not Suitable

Sulphuric Acid (10%) Sulphuric Acid (70%) Toluene Transformer Oil Not Suitable Not Suitable Not Suitable

Not Suitable

1,1,1-Trichloroethane Trichloroethylene Turpentine Vegetable Oil Vinyl Acetate Water White Spirit Zinc Chloride

Not Suitable

The information above is given as a guide only and is based on published technical data and experience. The chemical resistance of the above products is dependant on factors such as chemical exposure, concentration of the chemical and temperature. The above chemicals are valid for a temperature of 23 C. Use of the above table is at the users own discretion and risk. Those using it must satisfy themselves that their application presents no health and safety risks. The end user should assess compatibility with their application and contact Adaptaflex for further information.

Adaptaflex, Station Road, Coleshill, B46 1HT United Kingdom - Tel: +44(0)1675 468222 - Fax: +44(0)1675 464930 - e-mail: sales@adaptaflex.co.uk - www.adaptaflex.com

CONDUIT

02/09/2008 Conduit Very Flexible - Medium Fatigue Construction PVCu Spiral with plasticised covering

Technical Data Sheet

Page No.3

INSERT PICTURE HERE

Non-Metallic Systems TYPE XF -XTRAFLEX

Dimension charts for associated fittings XF FITTINGS

Adaptaflex, Station Road, Coleshill, B46 1HT United Kingdom - Tel: +44(0)1675 468222 - Fax: +44(0)1675 464930 - e-mail: sales@adaptaflex.co.uk - www.adaptaflex.com

Anda mungkin juga menyukai