Anda di halaman 1dari 2

Voltage

Degree of protection IP-54


16 (non volatile with time stamp)
10 (non volatile with time stamp) Fault Recorder
Event Recorder
1.0 kg
0
-25 to 70 C
CSENEX-I 100
CSENEX-I 100
Current Protect|on & Mon|tor|ng System
Features
Application
Communication
Test & Environments
Metering & Monitoring
Records
The CSENEX-I over current relays have been designed for
controlling, protecting & monitoring industrial, utility distribution
networks & substations.
They can also be used as backup protection scheme for feeders,
transformers and generators against over current.
1A & 5A Rated CT input (Site selectable)
Drawout with self CT shorting
SCADA Communication (Local & Remote)
Wide Auxiliary Supply range
DI / DO Freely programmability
Event Recorder
Fault Recorder
IEC 60255
(EMC Emission / Emmunity / Mechanical / EMI)
USB Plug & Play Interface for PC / Laptop
RS-485 MODBUS / IEC-103 (Remote)
Operating Temperature
Weight
Phase Current
Earth Current
Unbalance Current
18-60V DC / 18-150V DC /
85-280V AC / 110-300V DC
Rated Aux Voltage (UAUX)
Rated Phase Current (IP)
Current measuring range
Rated Neutral Current (IN)
1A/5A (site selectable)
30xIp
1A/5A (site selectable)
Thermal withstand Capacity At Ip = 1A
Continuous = 4xIp
for 10 sec = 30xIp
for 1 sec = 100xIp
Rated Frequency (FN) 50/60 Hz
Digital Input
Trip Contacts
02 Nos
04 Nos programmable
:
:
:
:
:
:
:
:
Technical Data
Protection & Control
3 Phase Time Over-current
3 Phase Instantaneous Current
Earth Time Over-current & Instantaneous
Trip Circuit Supervision
Circuit Breaker Failure Protection
22
156.0
125.0
1
5
4
.
0
E
L 3
L 2
L 1
ON
V R E O URRE T N C ELAY R
TRI P t I>
CHAR I>
PHASE
EARTH
COMM FACTORY PORT
I
I>>
IE>>
IE>
I>>
t
IE>>
t
CHAR I> t
IE>
IE> t
I
s
s
u
e

D
a
t
e
:

1
5
.
0
4
.
1
3
,

R
e
v
.

N
o
.
:

0
0
,

R
e
v
.

D
a
t
e
:

-
-
-
-
(Panel cutout dimensions (W x H} : 112.0 x 145.0mm}
CSENEX-I 100
Current Protect|on & Mon|tor|ng System
Model Selection Chart
Function ANSl NEX-l-100 NEX-l-101
CT inputs - 4 4
Over current 50/51
Earth fault 50N/51N
CBFP 50BF
Trip circuit 74TC x
lnrush blocking 51H x
Digital input - x 2
Digital output - 4 4
Fault record - 10 10
Event record - 16 16
Selection of 1/5A -
Front communication -
Rear comm. (RS-485} -
(Front view}
(Side view}
CSENEX-I X X X X
Rear Commun|cat|on
CT Short|ng
Rated Current
-C: RS-485 Modbus communication
-N: Non-Draw out (without CT shorting}
-1: 1A Rated Phase & Earth Current
-l: RS-485 lEC-103 Protocol
-0: No communication
-D: Draw out (with CT shorting}
-5: 5A Rated Phase & Earth Current
-S: 1A/5A Rated Phase & Earth Current site selectable
-Zx: Customer specific model
-: Standard model
Aux Supp|y
-L: 18v - 60v DC
-W1: 18v - 150v DC
-H: 85v - 280v AC / 110v - 300v DC
X X
Mode| No.
-100
-101
Ordering Information Dimension Details