Anda di halaman 1dari 3

Product Data Sheet

SIMACOVER EP GLASSFLAKE

3406 - 00
A - three page issue January 2008

DESCRIPTION Two component high solids glass flake reinforced polyamine cured epoxy coating PRINCIPAL CHARACTERISTICS RECOMMENDED USE Glass flake particularly used in areas of the subject to heavy impact, excellent corrosion resistant due to its low permeability and high electrolytic resistance SPECIFICATION DATA AT 20C Gloss Gloss Black (other colours on request) Colour Specific gravity Solids by volume Recommended Coverage theoretical Drying time 1.50 0.20 kg/litre 84 2 % Dry film thickness : Wet film thickness :
2

Excellent abrasion and impact resistance Long term protection for areas subject to heavy wear and tear Excellent resistance to corrosion Very low water permeability, due to glass flake barrier Tar free Resistance to splash and spillage of a wide range of chemicals Application and curing at temperatures down to 5C

400 microns 476 microns Touch dry 2.5 hours 2 hours 1.5 hours 1 hour Hard dry 7 hours 5 hours 4 hours 3 hours

2.1 m / litre 400 microns Temperature 26C 32C 36C 40C 7 days

Full cure Painting interval VOC Flash point (DIN 53213) Pot life Service temperature Shelf life SURFACE PREPARATION

Min : 8 hours Max : 30 days Max. 140 g/litre O O Base 27 C, hardener 24 C 3 hours (after mixing the components) o Continuous : 120 C Periodic : up to 120C 12 months (cool and dry place) New steel; blast cleaned to SSPC-SP 10, blasting profile (Rz) 70 100 microns Primed steel; (SIMACOVER EP PRIMER);Dry and free from any contaminants.

WE PROTECT YOUR INVESTMENT

Page 1 of 3

Jl. Lanbouw 1, Jagorawi-Cibinong Bogor, INDONESIA; 021-8756310-11, 8753043; F: 021-8753042; www.sigmautama.com ; cs@sigmautama.com

Product Data Sheet

SIMACOVER EP GLASSFLAKE

3406 - 00
A - three page issue January 2008

CONDITION OF APPLICATION Substrate temperature must be at least 5 C during application and curing. Relative humidity: maximum 85% o Substrate temperature should be at least 3 C above dew point Adequate ventilation must be maintained during application and curing SYSTEM SPECIFICATION Suitable primer : SIMACOVER EP PRIMER or according to the specification INSTRUCTION FOR USE - Mixing ratio by volume : base to hardener 3 : 1 o - The temperature of the mixture of base and hardener should be above 15 C, otherwise extra solvent may be required to obtain application viscosity. - To much solvent results in lower sag resistance and slower cure - Thinner should be added after mixing the components - Stir well before use, preferable by mechanical mixer to ensure good homogeneity. - Application with brush only for touch up and spot repair (due to thixothrophy it is difficult to obtain a smooth film by brush although this does not affect performance) APPLICATION DETAILS Method of application Thinner No. Volume of thinner Nozzle orifice Nozzle pressure Cleaning solvent

Airless spray 44-00 0-5% 0.021 0.031 190 225 Bar/2100 3200 psi Sima Thinner 49-00

Air spray 44-00 5 - 10% 0.062 0.079 3 - 4Bar /43 57psi

Brush 44-00 0 - 5% -

ADDITIONAL DATA Over coating table for epoxy paints : Substrate temperature Minimum interval Max. interval Curing table : Substrate temperature 5 C 10 C 20 C 32 C 40 C Touch dry 16 hours 8 hours 3 hours 2 hours 1 hour Hard dry 30 hours 8 hours 6 hours 5 hours 3 hours Full cure 10 days 7 days 5 days 4 days 2 days Pot life 5 hours 4 hours 3 hours 2 hours 1 hour 5 C 24 hours 30 days 10 C 12 hours 30 days 20 C 8 hours 30 days 32 C 6 hours 30 days 40 C 5 hours 30 days

WE PROTECT YOUR INVESTMENT

Page 2 of 3

Jl. Lanbouw 1, Jagorawi-Cibinong Bogor, INDONESIA; 021-8756310-11, 8753043; F: 021-8753042; www.sigmautama.com ; cs@sigmautama.com

Product Data Sheet

SIMACOVER EP GLASSFLAKE

3406 - 00
A - three page issue January 2008

SAFETY PRECAUTION - Avoid contact with the skin and eyes. - Wear suitable protective clothing such as overalls, goggles, dust mask and gloves. - Ensure that there is adequate ventilation in the area where the product is being applied. - Do not breathe the vapour or spray. - This product is flammable. - Keep away from sources of ignition. Do not smoke. HEALTH AND SAFETY: For detailed information on the health and safety hazards and precaution for use of this product, please see the MATERIAL SAFETY DATA SHEET. PACKING SIZE AND STORAGE Packing size (two packs product) : 5 and 20 litres Storage The product must be storage in accordance with national regulation. Preferred storage conditions are to keep the containers in the dry space provided with adequate ventilation. The containers should be sealed tightly

The 6th Edition


The information in this data sheet is to the best our knowledge connects at date printing. The company reserves the right to the modify data without notice. Any change in data will normally be followed by issued of new data sheet. The user should check the data of printing and if more than 12 months have elapsed, then the data should on only be used after checking with our nearest self-office to establish that they are still valid. Since condition of application and services may be beyond our control, no liability can accept on basis of this data.

WE PROTECT YOUR INVESTMENT

Page 3 of 3

Jl. Lanbouw 1, Jagorawi-Cibinong Bogor, INDONESIA; 021-8756310-11, 8753043; F: 021-8753042; www.sigmautama.com ; cs@sigmautama.com