1 June, 2006..............................................................................................................................................1 1 RNC Parameter.......................................................................................................................................3 1.1 Periodic Location Update Timer (T3212)...................................................................................3 1.2 Attach/detach indication (ATT)...................................................................................................4 1.3 Network mode of operation (NMO)............................................................................................4 1.4 BE service handover rate thresholdBEBITRATETHD..........................................................4 2 CellSelReselParas...................................................................................................................................5 2.1 Min quality level(Qqualmin).......................................................................................................5 2.2 Min RX level(Qrxlevmin)...........................................................................................................5 2.3 Max allowed UE UL TX powerMaxAllowedUlTxPower......................................................6 2.4 Reselection delay timeTresections..........................................................................................6 2.5 Hysteresis 2Qhyst2s................................................................................................................6 2.6 Intra-freq cell reselection thresholdSintrasearch....................................................................7 2.7 Inter-RAT cell reselection thresholdSsearchrat......................................................................7 3 CellPowerRatioParas..............................................................................................................................8 3.1 PCPICH transmit powerPcpichPower....................................................................................8 3.2 Max transmit power of PCPICH(MaxPcpichPower)..................................................................8 3.3 Min transmit power of PCPICH(MinPcpichPower)....................................................................9 4 CellIntraFreqHOMrParas........................................................................................................................9 4.1 Intra-freq meas L3 filter coeff (FilterCoef).................................................................................9 4.2 1A event relative threshold (IntraRelThdFor1A)......................................................................10 4.3 1B event relative threshold (IntraRelThdFor1B).......................................................................10 4.4 1A hysteresis(Hystfor1A)..........................................................................................................10 4.5 1B hysteresis(Hystfor1B)..........................................................................................................11 4.6 1C hysteresis(Hystfor1C)..........................................................................................................11 4.7 1D hysteresis(Hystfor1D)..........................................................................................................11 4.8 Weighted factor(WEIGHT).......................................................................................................12 4.9 1A event trigger delay time(TrigTime1A)................................................................................12 4.10 1B event trigger delay time(TrigTime1B)...............................................................................12 4.11 1C event trigger delay time(TrigTime1C)...............................................................................13 4.12 1D event trigger delay time (TrigTime1D).............................................................................13 5 CellInterRATHOMrParas.....................................................................................................................14 5.1 Inter-RAT filter coeff(FilterCoef).............................................................................................14 5.2 Inter-RAT period report interval(RptInterval)..........................................................................14 5.3 Inter-RAT CS handover decision THD(INTERRATCOVHOCSTHD)...................................15 5.4 Inter-RAT PS handover decision THD(INTERRATCOVHOPSTHD)....................................15 5.5 Inter-RAT hysteresis(HYSTFORINTERRAT).........................................................................15 5.6 Time to trigger for verified GSM cell(TIMETOTRIGFORVERIFY)......................................16 5.7 Inter-RAT CS measure start RSCP THD(INTERRATCSTHD2DRSCP)................................16 5.8 Inter-RAT CS measure stop RSCP THD(INTERRATCSTHD2FRSCP).................................16 5.9 Inter-RAT PS measure start RSCP THD(INTERRATPSTHD2DRSCP).................................17 5.10 Inter-RAT PS measure stop RSCP THD(INTERRATPSTHD2FRSCP)................................17 6 3G-3G NCELL......................................................................................................................................17 6.1 Cell offset (CELLINDIVIDALOFFSET).................................................................................17
6.2 Qoffset1sn (QOFFSET1SN)......................................................................................................18 6.3 Qoffset2sn (QOFFSET2SN)......................................................................................................18 7 3G-2G NCELL......................................................................................................................................19 7.1 Cell individual offset(CELLINDIVIDALOFFSET).................................................................19 7.2 QOFFSET1SN...........................................................................................................................19 7.3 QRXLEVMIN...........................................................................................................................19
1 1.1
RNC Parameter
Parameter setting:
Default: 10, namely 1 hour. The periodic update is completed by the MS through the location update process; 0 means that periodic update is disabled. This parameter is effective only when [CN domain identity] is CS_DOMAIN. If timer T3212 has not been started yet, when the UE enters NORMAL SERVICE of MM IDLE or the ATTEMPTing TO UPDATE substate, the UE will start timer T3212 and send the LOCATION UPDATING REQUEST message. If a response message such as LOCATION UPDATING ACCEPT or LOCATION UPDATING REJECT and AUTHENTICATION REJECT is received, it will stop timer T3212 and initialize it and wait for the next location update when the UE enters again NORMAL SERVICE or ATTEMPTing TO UPDATE substate. When timer T3212 expires, T3212 will be initialized, and the abovementioned location update will be started again.
If this parameter is too small, the UE will carry out location update frequently, resulting in a large number of location update messages on the Uu and Iu interfaces; if it is too big, the UE location message will probably not be timely updated.
Relevant commands:
Set this parameter through ADD CNDOMAIN, query it through LST CNDOMAIN, and modify it through MOD CNDOMAIN.
1.2
Set this parameter through ADD CNDOMAIN, query it through LST CNDOMAIN, and modify it through MOD CNDOMAIN.
1.3
Set this parameter through ADD CNDOMAIN, query it through LST CNDOMAIN, and modify it through MOD CNDOMAIN.
1.4
Physical value range: 8k, 16k, 32k, 64k, 128k, 144k, 256k, 384k Physical unit: bit/s Content: The bit rate threshold used to determine whether to perform soft handover for the Best Effort (BE) service on DCH. When the maximum bit rate of the BE service is lower than or equal to this threshold, the system will perform soft handover for this user to guarantee the service quality. If the maximum bit rate of the BE service is higher than the threshold, the system will perform intra-frequency hard handover for this user to avoid the too great effect of soft handover on the system capacity. Recommended value: D384 Set this parameter through SET HOCOMM, query it through LST HOCOMM
2 2.1
2.2
Min RX level(Qrxlevmin)
Value range: -58~-13. Physical value range: -115~-25; step: 2 (-58:-115; -57:-113; ..., 13:25 ). Physical unit: dBm. Content: The minimum required RX level corresponding to CPICH
RSCP. The UE can camp on the cell only when the measured CPICH RSCP is greater than the value of this parameter. Recommended value: -58. Set this parameter through ADD CELLSELRESEL,query it through MOD CELLSELRESEL
2.3
2.4
2.5
Hysteresis 2Qhyst2s
Value range: 0~20.
Physical value range: 0~40; step: 2. Physical unit: dB. Content: The hysteresis value for serving FDD cells in case the quality measurement for cell selection and reselection is set to CPICH Ec/No. It is related to the slow fading feature of the area where the cell is located. The greater the slow fading variance is, the greater this parameter. It is optional. If it is not configured, [Hysteresis 1] will be adopted as the value. Recommended value: None. Set this parameter through ADD CELLSELRESEL,query it through MOD CELLSELRESEL
2.6
2.7
threshold plus the [Qqualmin] of the cell, the inter-RAT cell reselection procedure will be started. Recommended value: 2. Set this parameter through ADD CELLSELRESEL,query it through MOD CELLSELRESEL
3 3.1
3.2
Max transmit power of PCPICH(MaxPcpichPower) Value range: -100~500. Physical value range: -10~50; step: 0.1. Physical unit: dBm. Content: This parameter should be set based on the actual system environment such as cell coverage (radius) and geographical
environment. In a certain proportion of soft handover area, it is of no help to improve the downlink coverage by raising PCPICH power. Recommended value: 346. Set this parameter through ADD PCPICH,query it through LST PCPICH
3.3
4 4.1
4.2
4.3
4.4
1A hysteresis(Hystfor1A)
Value range: 0~15 Physical value range: 0~7.5; step: 0.5 Physical unit: dB Content: The hysteresis value of the event 1A. This parameter value is related to the slow fading characteristic. The greater this parameter is set, the less ping-pong effect and misjudgement can be caused. However, in this case, the event cannot be triggered in time. Recommended value: 0
4.5
1B hysteresis(Hystfor1B)
Value range: 0~15 Physical value range: 0~7.5; step: 0.5 Physical unit: dB Content: The hysteresis value of the event 1B. This parameter value is related to the slow fading characteristic. The greater this parameter is set, the less ping-pong effect and misjudgement can be caused. However, in this case, the event cannot be triggered in time. Recommended value: 0
4.6
1C hysteresis(Hystfor1C)
Value range: 0~15 Physical value range: 0~7.5; step: 0.5 Physical unit: dB Content: The hysteresis value of the event 1C. This parameter value is related to the slow fading characteristic. The greater this parameter is set, the less ping-pong effect and misjudgement can be caused. However, in this case, the event cannot be triggered in time. Recommended value: 8
4.7
1D hysteresis(Hystfor1D)
Value range: 0~15 Physical value range: 0~7.5; step: 0.5 Physical unit: dB Content: The hysteresis value of the event 1D. This parameter value is related to the slow fading characteristic. The greater this parameter is set, the less ping-pong effect and misjudgement can be caused. However, in this case, the event cannot be triggered in time.
Recommended value: 8 Set this parameter through SET INTRAFREQHO,query it through LST INTRAFREQHO
4.8
Weighted factor(WEIGHT)
Value range: 0~20 Physical value range: 0~2; step: 0.1 Physical unit: None Content: This parameter is used to define the soft handover relative threshold based on the measured value of each cell in the active set. The greater this parameter is set, the higher the soft handover relative threshold. When this parameter is set as 0, the soft handover relative threshold is only for the best cell in the active set. Recommended value: 0
4.9
Physical value range: 0, 10,20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560, 5000 Physical unit: ms Content: The trigger delay time of the event 1B. This parameter value is related to the slow fading characteristic. The greater this parameter is set, the smaller the misjudgement probability, but the lower the response speed of the event to the measured signal changes. Recommended value: D640 Set this parameter through SET INTRAFREQHO,query it through LST INTRAFREQHO
Content: The trigger delay time of the event 1D. This parameter value is related to the slow fading characteristic. The greater this parameter is set, the smaller the misjudgement probability, but the lower the response speed of the event to the measured signal changes. Recommended value: D640 Set this parameter through SET INTRAFREQHO,query it through LST INTRAFREQHO
5 5.1
5.2
5.3
5.4
5.5
Inter-RAT hysteresis(HYSTFORINTERRAT)
Value range: 0~15. Physical value range: 0~7.5; step: 0.5. Physical unit: dB. Content: Determining whether to trigger inter-RAT handover decision together with quality threshold. The smaller the shadow fading is, the smaller the parameter value should be. Recommended value: 4. Set this parameter through SET INTERRATHOCOV,query it through LST INTERRATHOCOV
5.6
5.7
5.8
Physical unit: dBm. Content: If the CS service uses RSCP as measurement item, when the measurement value is higher than this threshold, the UE reports event 2F; the RNC sends a signalling to disable compressed mode and stop inter-RAT measurement. Recommended value: 90. Set this parameter through SET INTERRATHOCOV,query it through LST INTERRATHOCOV
5.9
6 6.1
Physical value range: -10~10; step: 0.5. Physical unit: dB. Content: Offset of cell CPICH measurement value. The sum of this parameter value and the actual measured value is used in UE event evaluation. In handover algorithms, this parameter is used for moving the border of a cell. It is configured according to the actual environment. Recommended value: 0. Set this parameter through ADD INTRAFREQNCELL,query it through LST INTERFREQNCELL
6.2
Qoffset1sn (QOFFSET1SN)
Value range: -50~50. Physical unit: dB. Content: Offset of cell CPICH RSCP measurement value in cell selection/reselection. It is used for moving the border of a cell. The greater the parameter value is, the smaller the probability of selecting neighboring cells. Recommended value: 0.
6.3
Qoffset2sn (QOFFSET2SN)
Value range: -50~50. Physical value: dBm. Content: Offset of cell CPICH Ec/No measurement value in cell selection/reselection. It is used for moving the border of a cell. The greater the parameter value is, the smaller the probability of selecting neighboring cells. Recommended value: 0.
INTERFREQNCELL
7 7.1
7.2
QOFFSET1SN
Value range: -50~50. Physical unit: dB. Content: Offset between inter-RAT neighboring cell and WCDMA cell. In cell selection/resection, the greater the parameter value is, the smaller the probability of selecting inter-RAT neighboring cells
7.3
QRXLEVMIN
Value range: -58 to -13. Physical value range: -115 to -25; step: 2. Physical unit: dBm. Content: Min RX level of inter-RAT cell.