Cell: +923317119697, +923477772208 Email:gabbas_engr98@yahoo.com

OBJECTIVE: ___________ _______________________________________________ To work in power organization that offers a management, creative, dynamic and professional environment. Where abilities can be utilized fully to achieve goals and to utilize experience worths.

QUALIFICATION B.Sc. Electrical Engineering

Professional Engineer PEC # ELECT/19757

Experience: _ 9+Years___________________________________________________ 1year as Assistant Engineer (O&M) 7 Years as Assistant Engineer (P&I) NTDCL Pakistan. 1year to date as Resident Engineer 500KV NTDCL (WAPDA) Pakistan. Trainings:______________________________________________________________ 32 weeks P&I training from TSG Terbela and Lahore. 15 weeks Management Training (WAPDA Staff College Islamabad). 15 weeks Technical Training (Grid Station). 03 weeks PLC training.

National Transmission and dispatch company (NTDCL) PAKISTAN_____________

Position 1: Period: Position 2: Period:

Assistant Engineer P&I at 500KV G/S Multan. 01/2004 to 12/2011 (7 Years). Deputy Manager (Resident Engineer) 500KV Grid Station Multan. 01/2012 to date

Expertise as Protection Engineer.___________________________________________

1. Commissioning/installation/testing of all kinds of protection Schemes & control schemes designed by TOSHIBA, GE, ALSTOM, SIEMENS, ABB, MG of 600MVA 500/220KV,450MVA 500/220KV, 160MVA 220/132KV Auto Transformers ABB,TBEA,SIEMNS,TOSHIBA,JSHP make and 500KV,220KV & 132KV Transmission Lines, 500KV&220KV Bus Bar used in NATIONAL TRANSMISSION PAKISTAN Having hands on Experience to designed/Modified the Breaker failure Protection Scheme and 220KV BUS BARS 1&2 Protection Scheme during Extension of 220KVGrid at 500KV Multan. Having hands on Experience to Test/Modify the Control Circuit, Tripping Circuit, AC & DC Circuits, CT Circuits, CCVT/CVT, PT Circuits and Trip Circuit Supervision of Auto Transformers and Transmission Lines, shunt reactors and bus bars schemes. Have an Experience to test Temperature Gauges (Winding), CT circuit of Transformer, Shunt Reactors etc. Have an experience to Test Wiring of AC/DC (220 ,110 Volts )Supply Distribution to Control Panels, Relay Panels Marshaling Kiosk and Circuit Breakers / Isolators & Transformers /Shunt Reactor Cubical Box etc. Have an Experience of commissioning 220V DC Battery Charger in addition. Have good experience of CT Circuit and rectified many times faults in the CT circuit of Differential/Distance Protective Relays at 500KV G/S Multan. AND DESPATCH COMPANY LIMITED (NTDCL)

2. Experience & Knowledge of Troubleshooting and root cause analysis of faults in control circuits, CT & CCVT/CVT circuits and tripping circuits of AUTO Transformers, Transmission Lines, BUS BARS schemes. Have a Sound experience and knowledge about the faults related with control circuits of Auto transformers, Bus bar , Shunt Reactors Transmission Lines Circuit Breakers. Having hands on Experience about the faults related to CCVT/CVT circuit of Distance Protective relay, Over Voltage relay installed at transmission lines. Troubleshoot the tripping circuits of Auto Transformers, Power Transformers & transmission lines in case of failure of one of the main protection installed at these equipment. and

3. Testing/Commissioning/Installation of different type of protective relays of TOSHIBA, GE, ALSTOM, SIEMENS & ABB Make for AUTO Transformers, Shunt Reactors, and BUS BAR and Transmission lines with Universal Testing Sets and relevant software. Having hands on Experience of installation /commissioning /Testing of

following Protective Relays. SrNO. 01 02 03 04 05 06 Nomenclature of relays Differential Distance Breaker Failure Over Load/Over Current Distance OPTIMHO LOW Impedance Bus Bar 07 MICROMHO Quadramho 08 09 10 Over Current Over Voltage Biased Differential SHNB102 SHPM MCGG, MCAG MVTU, MVTD MBCH GEC GEC GEC GEC GEC Type of relay T6o D60 C60 MFII LZF11 MBCZ Make GE GE GE GE ALSTOM ALSTOM

SrNO. 11 12 13 14 15 16 17 18 19

Nomenclature of relays Breaker Failure Distance Differential Distance Over Current Distance Over Voltage Differential Differential

Type of relay MCTI 7SA52 7UT612 7SA513 7SJ6000 LZ96, LZ96a UT91 TBB7B GBT4D

Make GEC SIEMENS SIEMENS SIEMENS SIEMENS ABB ABB TOSHIBA TOSHIBA

Having hands on Experience of using following testing sets Type of Testing Set FREJA F6150 C&DF M2HE PRIMARY INJECTION PT-3000 Make MEGGER DOBLE DOBLE AG POWER

SrNO. 01 02 03 04

05

SECONDRY INJECTION MICRO TEST 860

AG POWER

06

TTR TEST SET TRT30D

DV POWER

07

Transformer Winding Resistance Test Set WRM-10

08

Battery Impedance Test Set BITE2

ENERVEK

09 10 11 12 13 14 15

SF6 Gas Purity Test Set TM1600 SF6 Gas Dew Point Meter 5KV MEGGER TEST AC HI-POT 130KV DC HI-POT 160KV ZFB Distance Relay Test Set

DILLO

DILLO MEGGER PROGRAMA BIDDLE GEC

4. Complete Testing of EHV&HV Substation Equipments such as Current Transformer, Potential Transformer, Auto Transformers, and Capacitor Voltage Transformer & Coupling Capacitor Voltage Transformer. Testing of Ear thing Mesh and HT cables etc.

Computer Skills MS Office, Window XP, Metering Software, Relays software (DIGSI, ENERVISTA, OPTICOM) Other Skills Communication ENGLISH, URDU