Anda di halaman 1dari 36

JC International Limited

RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 16909 Identification Number Qty

Date of Examination 11/07/2013

Examiner PHILEMON ATAHINE TARE WT

Qualifications LEEA, SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

SHACKLE

1019551/13

Bow safety pin shackle.

N/A

8.5 Tonnes

N/A

N/A
10-01-14

LOCATION: SHAKER AREA


SPECIFICATION : BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: 4 lifting points and Entire Body RESULTS: No defect as at the time of inspection.
Name and address of equipment owner: OANDO ENERGY SERVICES

Fit for use


Address of premises where Test / Examination was held:

OES PASSION

We hereby certify that 11/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: PHILEMON ATAHINE Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 16910 Identification Number Qty

Date of Examination 11/07/2013

Examiner PHILEMON ATAHINE TARE WT

Qualifications LEEA, SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

SHACKLE

P 27

Bow safety pin shackle.

N/A

2 Tonnes

N/A

N/A
10-01-14

LOCATION: UNDER RIG FLOOR


SPECIFICATION : BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: 4 lifting points and Entire Body RESULTS: No defect as at the time of inspection.
Name and address of equipment owner: OANDO ENERGY SERVICES

Fit for use


Address of premises where Test / Examination was held:

OES PASSION

We hereby certify that 11/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: PHILEMON ATAHINE Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 16911 Identification Number Qty

Date of Examination 11/07/2013

Examiner PHILEMON ATAHINE TARE WT

Qualifications LEEA, SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

SHACKLE

P 67

Bow safety pin shackle.

N/A

2 Tonnes

N/A

N/A
10-01-14

LOCATION: UNDER RIG FLOOR


SPECIFICATION : BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: 4 lifting points and Entire Body RESULTS: No defect as at the time of inspection.
Name and address of equipment owner: OANDO ENERGY SERVICES

Fit for use


Address of premises where Test / Examination was held:

OES PASSION

We hereby certify that 11/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: PHILEMON ATAHINE Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 16912 Identification Number Qty

Date of Examination 11/07/2013

Examiner PHILEMON ATAHINE TARE WT

Qualifications LEEA, SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

SHACKLE

P 21

Bow safety pin shackle.

N/A

2 Tonnes

N/A

N/A
10-01-14

LOCATION: UNDER RIG FLOOR


SPECIFICATION : BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: 4 lifting points and Entire Body RESULTS: No defect as at the time of inspection.
Name and address of equipment owner: OANDO ENERGY SERVICES

Fit for use


Address of premises where Test / Examination was held:

OES PASSION

We hereby certify that 11/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: PHILEMON ATAHINE Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 16913 Identification Number Qty

Date of Examination 11/07/2013

Examiner PHILEMON ATAHINE TARE WT

Qualifications LEEA, SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

SHACKLE

BS 20

Bow safety pin shackle.

N/A

4.75 Tonnes

N/A

N/A
10-01-14

LOCATION: UNDER RIG FLOOR


SPECIFICATION : BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: 4 lifting points and Entire Body RESULTS: No defect as at the time of inspection.
Name and address of equipment owner: OANDO ENERGY SERVICES

Fit for use


Address of premises where Test / Examination was held:

OES PASSION

We hereby certify that 11/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: PHILEMON ATAHINE Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 16914 Identification Number Qty

Date of Examination 11/07/2013

Examiner PHILEMON ATAHINE TARE WT

Qualifications LEEA, SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

SHACKLE

BA 01

Bow safety pin shackle.

N/A

4.75 Tonnes

N/A

N/A
10-01-14

LOCATION: UNDER RIG FLOOR


SPECIFICATION : BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: 4 lifting points and Entire Body RESULTS: No defect as at the time of inspection.
Name and address of equipment owner: OANDO ENERGY SERVICES

Fit for use


Address of premises where Test / Examination was held:

OES PASSION

We hereby certify that 11/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: PHILEMON ATAHINE Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 16915 Identification Number Qty

Date of Examination 11/07/2013

Examiner PHILEMON ATAHINE TARE WT

Qualifications LEEA, SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

SHACKLE

SDT 1

Bow safety pin shackle.

N/A

2 Tonnes

N/A

N/A
10-01-14

LOCATION: UNDER RIG FLOOR


SPECIFICATION : BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: 4 lifting points and Entire Body RESULTS: No defect as at the time of inspection.
Name and address of equipment owner: OANDO ENERGY SERVICES

Fit for use


Address of premises where Test / Examination was held:

OES PASSION

We hereby certify that 11/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: PHILEMON ATAHINE Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 16916 Identification Number Qty

Date of Examination 11/07/2013

Examiner PHILEMON ATAHINE TARE WT

Qualifications LEEA, SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

SHACKLE

VN 1

Bow safety pin shackle.

N/A

8.5 Tonnes

N/A

N/A
10-01-14

LOCATION: UNDER RIG FLOOR


SPECIFICATION : BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: 4 lifting points and Entire Body RESULTS: No defect as at the time of inspection.
Name and address of equipment owner: OANDO ENERGY SERVICES

Fit for use


Address of premises where Test / Examination was held:

OES PASSION

We hereby certify that 11/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: PHILEMON ATAHINE Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17020 Identification Number Qty

Date of Examination
12/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE

SH 01

Bow Safety Pin Shackle

N/A

6.5 tonnes

N/A

N/A

11-01-14

LOCATION: MOON POOL


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 12/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17021 Identification Number Qty

Date of Examination
12/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
1

Bow Safety Pin Shackle

N/A

8.5 tonnes

N/A

N/A

11-01-14

LOCATION: MOON POOL


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 12/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17022 Identification Number Qty

Date of Examination
12/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
98/1 1

Bow Safety Pin Shackle

N/A

6.5 tonnes

N/A

N/A

11-01-14

LOCATION: MOON POOL


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 12/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17023 Identification Number Qty

Date of Examination
12/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
98/ 1

Bow Safety Pin Shackle

N/A

6.5 tonnes

N/A

N/A

11-01-14

LOCATION: MOON POOL


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 12/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17024 Identification Number Qty

Date of Examination
12/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
VLC 1 1

Bow Safety Pin Shackle

N/A

6.5 tonnes

N/A

N/A

11-01-14

LOCATION: MOON POOL


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 12/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17025 Identification Number Qty

Date of Examination
12/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
VLC 2 1

Bow Safety Pin Shackle

N/A

6.5 tonnes

N/A

N/A

11-01-14

LOCATION: MOON POOL


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 12/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17026 Identification Number Qty

Date of Examination
12/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
1019597/1 1

Bow Safety Pin Shackle

N/A

12 tonnes

N/A

N/A

11-01-14

LOCATION: RIG FLOOR


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 12/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17027 Identification Number Qty

Date of Examination
12/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
DD 1 1

Bow Safety Pin Shackle

N/A

8.5 tonnes

N/A

N/A

11-01-14

LOCATION: RIG FLOOR


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 12/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17028 Identification Number Qty

Date of Examination
12/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
OP 24 1

Bow Safety Pin Shackle

N/A

6.5 tonnes

N/A

N/A

11-01-14

LOCATION: RIG FLOOR


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 12/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17029 Identification Number Qty

Date of Examination
12/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
002/3 1

Bow Safety Pin Shackle

N/A

6.5 tonnes

N/A

N/A

11-01-14

LOCATION: RIG FLOOR


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 12/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17030 Identification Number Qty

Date of Examination
12/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
1019551/12 1

Bow Safety Pin Shackle

N/A

8.5 tonnes

N/A

N/A

11-01-14

LOCATION: RIG FLOOR


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 12/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17031 Identification Number Qty

Date of Examination
12/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
DD 2 1

Bow Safety Pin Shackle

N/A

4.75 tonnes

N/A

N/A

11-01-14

LOCATION: RIG FLOOR


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 12/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17032 Identification Number Qty

Date of Examination
12/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
OP 16 1

Bow Safety Pin Shackle

N/A

6.5 tonnes

N/A

N/A

11-01-14

LOCATION: RIG FLOOR


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 12/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17033 Identification Number Qty

Date of Examination
12/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
1019551/14 1

Bow Safety Pin Shackle

N/A

8.5 tonnes

N/A

N/A

11-01-14

LOCATION: RIG FLOOR


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 12/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17034 Identification Number Qty

Date of Examination
13/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
04B 1

Bow Safety Pin Shackle

N/A

6.5 tonnes

N/A

N/A

12-01-14

LOCATION: SHELL WARE HOUSE


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 13/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17035 Identification Number Qty

Date of Examination
13/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
PM 02 1

Bow Safety Pin Shackle

N/A

12 tonnes

N/A

N/A

12-01-14

LOCATION: SHELL WARE HOUSE


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 13/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17036 Identification Number Qty

Date of Examination
13/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
1019551/6 1

Bow Safety Pin Shackle

N/A

8.5 tonnes

N/A

N/A

12-01-14

LOCATION: SHELL WARE HOUSE


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 13/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17037 Identification Number Qty

Date of Examination
13/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
111 1

Bow Safety Pin Shackle

N/A

4.75 tonnes

N/A

N/A

12-01-14

LOCATION: SHELL WARE HOUSE


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 13/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17038 Identification Number Qty

Date of Examination
02/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
V1 1

Bow Safety Pin Shackle

N/A

8.5 tonnes

N/A

N/A

01-01-14

LOCATION: PIPE DECK


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 02/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17039 Identification Number Qty

Date of Examination
02/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
V2 1

Bow Safety Pin Shackle

N/A

8.5 tonnes

N/A

N/A

01-01-14

LOCATION: PIPE DECK


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 02/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17040 Identification Number Qty

Date of Examination
02/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
1019551/A 1

Bow Safety Pin Shackle

N/A

8.5 tonnes

N/A

N/A

01-01-14

LOCATION: PIPE DECK


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 02/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17041 Identification Number Qty

Date of Examination
02/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
V3 1

Bow Safety Pin Shackle

N/A

8.5 tonnes

N/A

N/A

01-01-14

LOCATION: PIPE DECK


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 02/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17042 Identification Number Qty

Date of Examination
02/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
OP 28 1

Bow Safety Pin Shackle

N/A

6.5 tonnes

N/A

N/A

01-01-14

LOCATION: PIPE DECK


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 02/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17043 Identification Number Qty

Date of Examination
02/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
1019597/17 1

Bow Safety Pin Shackle

N/A

12 tonnes

N/A

N/A

01-01-14

LOCATION: PIPE DECK


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 02/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17044 Identification Number Qty

Date of Examination
02/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
V4 1

Bow Safety Pin Shackle

N/A

12 tonnes

N/A

N/A

01-01-14

LOCATION: PIPE DECK


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 02/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17045 Identification Number Qty

Date of Examination
02/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
OP 3 1

Bow Safety Pin Shackle

N/A

12 tonnes

N/A

N/A

01-01-14

LOCATION: PIPE DECK


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 02/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17046 Identification Number Qty

Date of Examination
02/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
V5 1

Bow Safety Pin Shackle

N/A

17 tonnes

N/A

N/A

01-01-14

LOCATION: PIPE DECK


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 02/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.
17047 Identification Number Qty

Date of Examination
02/07/2013

Examiner
PHILEMON ATAHINE

Qualifications
LEEA,SNT LEVEL II MT, PT & UT SWL GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

TARE WT

SHACKLE
V6 1

Bow Safety Pin Shackle

N/A

13.5 tonnes

N/A

N/A

01-01-14

LOCATION: PIPE DECK


SPECIFICATION: BS EN 13889 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire body


RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: OANDO ENERGY SERVICES

Address of premises where Test / Examination was held: PASSION RIG

We hereby certify that on 02/07/2013 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: PHILEMON ATAHINE Conducting: Examination only Doc No: JCI-C-V-01

Anda mungkin juga menyukai