Anda di halaman 1dari 6

Return Filters

Tank top mounting / In-line mounting

20.10-2e

D 023 D 043
Connection Nominal flow rate G up to 45 l/min

Q ua lit y

m an ag em en t

ac co rd in g

to

DI N

EN

IS O

90 01

Description
Application In the return line circuits of hydraulic systems. Performance features Protection against wear: By means of filter elements that, in fullflow filtration, meet even the highest demands regarding cleanness classes. Protection against malfunction: By means of full-flow filtration in the system return, the pumps above all are protected from dirt particles remaining in the system after assembly, repairs, or which are generated by wear or enter the system from outside. Special features By-pass valve: The location close to the inlet port prevents dirt particles retained by the filter element from entering into the clean oil side. Dirt collecting bowl: Prevents back-flushing of collected dirt particles during element replacement. Connection: A female thread in the bowl outlet makes in-line mounting possible. Filter elements Flow direction from outside to centre. The star-shaped pleating of the filter material results in: large filter surface high dirt-holding capacity low pressure drop long service life In filters with a magnetic system, the ferromagnetic particles in the fluid pass first through a strong magnetic field and are separated. Ventilating Filter Ventilation of the reservoir by an integral star-shape pleated filter element: removable (replace annually!) splash-proof fineness 7 m Some versions are also available with galvanized steel wool. Filter maintenance By using a clogging indicator the correct moment for maintenance is stated and guarantees the optimum utilization of the filter elements. Materials Screw-on cap: Housing: Seals: Filter media: Polyamide, GF reinforced Aluminium alloy NBR (Viton on request) Exapor - inorganic microfibre web Paper - cellulose web, impregnated with resin Stainless steel wire mesh (1.4301) with mesh size 40, 60 and 75 m, bronce screen (2.1020) is used with 100 m

Accessories An optional oil separator (Part No. D 023.1702) prevents oil splashing through the ventilating filter at mobile applications. Electrical and optical clogging indicators are available. Dimensions and technical data see Spec. Sheet 60.20.

Characteristics
Nominal flow rate Up to 45 l/min (see Selection Chart, column 2) The nominal flow rates indicated by ARGO are based on the following features: closed by-pass valve at 200 mm2/s element service life 1000 operating hours at an average fluid contamination of 0,08 g per l/min flow volume flow velocity in the connection lines 4,5 m/s Connection Threaded ports according to ISO 228 or DIN 13. Sizes see Selection Chart, column 6 (other port threads on request) Filter fineness 10 m ... 100 m -values according to ISO 4572-81 (see Selection Chart, column 4 and Diagram Dx) ACFTD capacity -values in g test dust ACFTD according to ISO 4572-81 (see Selection Chart, column 5) Hydraulic fluids Mineral oil and biodegradable fluids (see info-service 00.20) Temperature range - 30 C ... + 100 C (- 40 C in starting phase) Viscosity at nominal flow rate < 60 mm2/s at operating temperature max = 1200 mm2/s as starting viscosity at first operation: The recommended starting viscosity can be read from the Diagram D (pressure drop as a function of the kinematic viscosity) as follows: Find the 70% p of the cracking pressure of the by-pass valve on the vertical axis. Draw a horizontal line so that it intersects the p curve at a point. Read this point on the horizontal axis for the viscosity. Operating pressure Max. 16 bar Mounting position Preferably vertical, outlet downwards under the minimum oil level

20.10-2e

2/6

Diagrams
p-curves for complete filters in Selection Chart, column 3

D1

Pressure drop as a function of the flow volume at = 35 mm2/s (0 = casing empty)

Pressure drop as a function of the kinematic viscosity at nominal flow

p [bar]

p [bar]

Q [l/min]

[mm2/s] Pressure drop as a function of the kinematic viscosity at nominal flow

D2

Pressure drop as a function of the flow volume at = 35 mm2/s (0 = casing empty)

p [bar]

p [bar]

Q [l/min]

[mm2/s]

Filter fineness curves in Selection Chart, column 4

Dx

Filtration ratio as a function of particle size x obtained by the Multi-Pass-Test similar to ISO 4572-81
The abbreviations represent the finenesses: For Exapor and Paper elements: 3 E = 3 75 Exapor ( 3 m 10 E = 10 75 Exapor (10 m 20 E = 20 75 Exapor (20 m 10 PA 15 P following -values resp.

abs.) abs.) abs.)

35 75 Paper 60 75 Paper

(10 m nom.) (15 m nom.)

Filtration ratio for particles > x m

Efficiency [%]

Based on the structure of the filter media of the 10 PA and 15 P paper elements, deviations from the printed curves are quite probable. For screen elements: 40 S = screen material with mesh size 40 m 60 S = screen material with mesh size 60 m 75 S = screen material with mesh size 75 m 100 S = screen material with mesh size100 m Tolerances for mesh size according to DIN 4189. For ventilating filter elements: 2 EL = 99% filter efficiency for particles 2 m 7 PL = 99% filter efficiency for particles 7 m according to a single-pass test with ACFTD

Dotted characteristics apply if pEnd = 0,25 bar

Particle size x [m] (for particles larger than the given particle size x)

For special applications, finenesses differing from these curves are also available by using special composed filter media.
20.10-2e 3/6

Selection Chart
s Dx as r. -p g y t a b en Di of o. it) m e e n ) e n ( u se se ve ur ele ity B ss ss pac ce in sic A/ op /cur nt w e r e a r e o n d n l p B D ca rfa l f re tio em . .( ne ing bol ec na ssu ram er fi FTD r su ac t No ht i k No l n c t p g e t m n r m r e a a eig Fil AC Filt Re Pa No Pr Di Co Pa Cr Sy W g bar kg l/min

m Re

ar

ks

1 D 023-05 D 023-01

2 15 25

3 D1/1 D1/2

6 G G *

7 -

8 8 8

10

11

12

40 S (80 cm) 100 S (80 cm)

S0.0408-05 0,4 steel wool breather with magnetic system S0.0408-01 0,4 steel wool breather with magnetic system

D 043-56 D 043-58 D D D D D 043-51 043-73 043-52 043-82 043-84

23 35 30 30 45 45 45 40 45 45

D2/1 D2/2 D2/3 D2/3 D2/4 D2/4 D2/4 D2/5 D2/6 D2/6

10 E 20 E 10 PA 10 PA 15 P 15 P 15 P

3,5 5,5 5 5 6 6 6

G * G * G * G G * G * G * G G G *

2,5 2,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5

2 2 2 1 2 1 2 2 5 2

V3.0510-56 0,4 L1.0406-01 (7 PL) V3.0510-58 0,4 L1.0406-01 (7 PL) P3.0510-51 P3.0510-51 P3.0510-50 P3.0510-50 P3.0510-50 0,4 L1.0406-01 (7 PL) 0,4 0,4 steel wool breather 0,4 0,4 L1.0406-01 (7 PL)

D 043-05 D 043-10 D 043-00

40 S (220 cm) 60 S (220 cm) 60 S (220 cm)

S3.0508-55 0,45 steel wool breather S3.0508-50 0,47 steel wool breather with magnetic system S3.0508-50 0,45 steel wool breather -

As clogging indicators either manometers or electrical pressure switches can be used. Optional extension pipes adapt the filter length to various tank depths. For ordering of accessories please use the below mentioned codes. Order example: The filter D 043-56 has to be supplied with an extension pipe for a mounting depth of 200 mm and with a manometer. Order description: Part No. (Basic unit) Mounting depth ET (mounting depth) in mm, according to chapter "Dimensions" Clogging indicators and connection A = Connection M 12 x 1,5 in the filter head 0 = Manometer DG 200-06 red area from 1 = Manometer DG 200-05 red area from 2 = Pressure switch DG 812-00 switching pressure 3 = Pressure switch DG 812-01 switching pressure Technical data see Spec. Sheet 60.20. D 043-56 / ET 200 / A0

2,0 bar 1,0 bar 1,2 bar 2,0 bar

4 5 6 7 8

= = = = =

Protection cap Pressure switch Pressure switch Pressure switch Pressure switch

DG DG DG DG DG

812.0701 815-01 815-02 815-11** 815-12**

for pressure switch switching pressure switching pressure switching pressure switching pressure

DG 812 1,2 bar 2,0 bar 1,2 bar 2,0 bar

Remarks: The switching pressure of the electrical pressure switch has always to be lower than the cracking pressure of the by-pass valve (see Selection Chart, column 7). The clogging indicators are always delivered detached from the filter. The filters listed in this chart are standard filters. Other designs available on request.
* No female thread in the bowl outlet ** With LED for optical indication 20.10-2e 4/6

Dimensions
, , , , , , , , , , , , , , , , , , , , , , ,

Ventilating filter with galvanized steel wool

Oil separator optional ARGO Part No.: D 023.1702

Dia hole in reservoir

Required mounting surface

Connection M 12 x 1,5 for clogging indicator on request

Ventilating filter Fineness 7 m with protection cap

, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

Measurements
Type A B* C
min./max.

D 52 52

H 67 67

I1 125 150

I2 72

K 87,5 87,5

L 88 88

M 9 9

N 50 50

P1 45 45

D 023 G G 60/63 D 043 G G 60/63

33,5 11,5 24 33,5 11,5 24

11 11 68,5

9,5 75,5 73,5 9,5 75,5 73,5

* see also Selection Chart, column 6

Symbols
1 2 3 4 5 6 7 8

20.10-2e

5/6

Spare Parts
Pos. 1b 1.1 1a 1.2 1a 1b 1.1 1.2 2 2 3 4 5 3 6 7 8 4 5 Designation Screw cap assy (with Pos. 2) Screw cap assy (with Pos. 2) Screw cap Magnetic system Seal Filter element Ventilating filter (with Pos. 5) Clip Flat gasket Oil separator (with Pos. 8) Flat gasket Part No. D 043.1210 D 023.1210 D 043.2202 MO.2501-00 N 031.0562 see Chart / col. 9 L1.0406-01K7 N 026.0253 D 023.0704 D 023.1702 D 023.0718

6 7 8

The functions of the complete filters as well as the outstanding features of the filter elements assured by ARGO can only be guaranteed if original ARGO spare parts are used.

Quality Assurance
To ensure constant quality in production and operation, ARGO filter elements undergo strict controls and tests according to the following DIN and ISO standards: DIN ISO 2941-83 Verification of collapse/burst resistance DIN ISO 2943-90 Verification of material compatibility with fluids DIN ISO 3724-90 Verfication of flow fatigue characteristics ISO 2942-94 Verification of fabrication integrity (Bubble Point Test) ISO 3968-81 Evaluation of pressure drop versus flow characteristics ISO 4572-81 Multi-pass method for evaluating filtration performance Various quality controls during the production process guarantee the leakfree function and solidity of our filters.

Our engineers will be glad to advice you in questions concerning filter application, selection as well as the cleanness class of the filtered medium attainable under practical operating conditions.
Illustrations may sometimes differ from the original. ARGO is not responsible for any unintentional mistake in this specification sheet.

FSP Fluid Systems Partners GmbH


ARGO Filtration Division D-76703 Kraichtal / Germany Tel. E-Mail +49-(0) 7250-76-0 argo@fluid-systems-partners.de Fax +49-(0) 7250-76-199 Internet www.argo.de
20.10-2e 6/6

Subject to change 9107163-e / 11.00

Anda mungkin juga menyukai