Anda di halaman 1dari 6

C PLUG

OLD OTIS type

The Type C Equalizing Plug is an equalizing sub that holds pressure generated from the bottom only. It can be used as a pump through plug if needed. When used in conjunction with the Type B, H, and F Equalizing Subs, the upper end of the bean housing serves as a valve which seats and seals on a tapered seat that is present in all Type B, H, and F subs. This same tapered seat is present in the B and W Mandrels so that the C Plug could be used on them without another equalizing sub made up to it. The bean has a secondary valve which sticks out above the bean that must be pushed off seat, using an equalizing prong made up the the proper pulling tool, in order to equalize. This is accomplished by applying tool string weight on it prior to pulling the locking mandrel.

SPECIFICAT IONS
2" 2" 2 1/2" 3" 3" Thread Connection 1 3/16"-14 1 9/16"-12 2"-12 Flow Area Equalizing Button .0075" .0075" .0075" (Sq. In.) Roll Pin 1/4" x 3/4" 1/4" x 7/8" 1/4" x 1 7/16"

B-4

D PLUG

(1 1/2, 1 3/4)

OLD OTIS TYPE

The Type D Equalizing Plug is a plug that is designed to hold pressure from below. It can be used in conjunction with many locking devices to bleed off a well in order to perform repairs or replacement of surface equipment. It also has pump through capabilities that would allow an operator to kill a well. A pulling prong is needed to equalize these subs. The prong actuates a secondary valve which allows either fluid bypass or pressure equalization.

SPECIFICAT IONS
Max. O.D. Thread Connection Flow Area Pump Down (sq. in.) Flow Area Equalizing Button (sq. in.) Roll Pin 1 1/2", 1 3/4" 1.250" 7/8"-14 .149" .003" 1/16" x 1/2"

B-8

TICXR PUMP THROUGH PLUG


OLD OTIS TYPE
The Type TICXR Pump Through Plug is used in conjunction with the Type TICX Locking Mandrel and the Type TICX Equalizing Sub Assembly to hold pressure from below in a Type TICX Landing Nipple. This plug has pump through capabilities that would allow an operator to pump fluids into well bore.

SPECIFICATIONS
Max. O.D. Thread Connection Flow Area (Seat Hole) (sq. in.) 1 1/2" 2" 2" 2 1/2" 3" 3" 1.325" 1.750" 2.00" 2.570" 1 1/8"-16 1 3/8-14 1 3/4"-12 2 1/4"-12 SLB .306" .371" .690" .861"

ASSEMBLY

Part Number Unit Price

21TICXR3150 360.00

1 1/2

21TICXR3200 360.00

21TICXR3250 435.00

2 1/2

21TICXR3300 545.00

COMPONENTS
Cap

21B01511 267.00 21B01512 74.00 21B01510 73.00 90A01499 16.00 95SS0075 11.00 ********

21B01502 267.00 21B01501 74.00 21B01509 73.00 90A01044 27.00 95SS0094 16.00 ********

21B01503 323.00 21B01504 84.00 21B01508 73.00 90A00895 29.00 95SS0154 22.00 ********

21B01505 407.00 21B01506 92.00 21B01507 92.00 90A01136 32.00 95SS0125 26.00 #033 1.10 ********

Seat Spring Sleeve Spring Ball O-ring

INCONEL SPRINGS (OPTIONAL)


Spring

********

90N02120 51.00

90N02121 51.00

Prices effective June 1, 2012

1-800-338-0308

B-2 7

DUAL FLAPPER CHECK VALVE


The Dual Flapper Check Valve is a device used to prevent pressure or fluid from passing up through the assembly. It is used in conjunction with a TICX or TICR Locking Mandrel. The Dual Flapper Check Valve has two flapper assemblies with seals to prevent pressure of fluid bypass upwards. The Dual Flapper Check Valve is a back pressure valve that allows the operator to pump through the assembly while allowing maxiumum flow through the assembly with minimal restriction. Equalization can be achieved by placing an equalizing sub above the assembly, or by running a prong attached to the pulling tool that will knock both flappers off seat.

SPECIFICATIONS
MAX. O.D. O-RING (2) O-RING (2) TOP CONNECTION BOTTOM CONNECTION FLOW AREA (SQ. IN.) 1 1/2" 2" 2" 2 1/2" 1.328" 1.750" 2.156" #116 #122 #128 #116 #215 #221 1 1/8"-16 1 3/8"-14 1 3/4"-12 3/8" NPT 1/2" NPT 3/4" NPT .374" .785" .208"

B-28

Pump Thru Check Valve


The Pump Thru Check Valve is designed to fit onto the Peak SIM Plug and most standard wireline conveyed lock assemblies and is used where there is a requirement to hold tubing pressure from below whilst allowing a maximum pump through capability.
The Peak design incorporates several key differentiating features including a reversible metal-to-metal seal for optimum working life, a secondary bronze filled Teflon seal to initiate metal to metal sealing at low pressures and mass reduction in the piston valve to reduce stress loading on the Inconel Return Spring also designed to extend working life. Applications The Pump Thru Check Valve can be used when there is a requirement to hold tubing pressure from below whilst allowing a pump through capability Features & Benefits Reversible metal-to-metal seal designed to extend working life Secondary bronze filled Teflon seal to initiate metal to metal sealing at low pressures Mass reduction in the Piston Valve reducing Return Spring stress extending working life Sour service components to industry specifications Robust and simplistic design

Technical Information
Nominal Lock Assembly 2 3/8 2 7/8 3 1/2 4 1/2 5 5 1/2 7 * Pressure Rating 5,000 psi 5,000 psi 5,000 psi 5,000 psi 5,000 psi 5,000 psi 5,000 psi

* Higher pressure ratings available on request

Pump Thru Check Valve (revision 03 April 2013) Product Code: 335

info@peakwellsystems.com www.peakwellsystems.com

Pump Open Sub


When deployed as part of a downhole plug assembly, the Pump Open Sub is primarily designed to act as a single barrier against well-bore contents.
The Pump Open Sub Plunger is secured in place with a series of shear screws which are designed to shear out when a predetermined pressure is applied from above the Pump Open Sub. Once the Plunger is sheared out, there is a clear flow path through the Pump Open Sub. This allows for full equalisation across the barrier device, circulation, communication to prevent recovery of wet tubing strings or production of well bore contents. Applications When deployed as part of a downhole plug assembly, the Pump Open Sub can be: used as a barrier to allow setting of hydraulically-set packers having to make an equalising run prior to plug recovery remotely opened by pressuring the tubing above to the pre-set shear rating. The well can then be brought back online without any intervention used for creating tubing overbalance prior to Fracture Stimulation Operations deployed as a contingent equalising device in high debris environments used as a mechanical barrier during wellhead removal / tree valve maintenance Features & Benefits Can be retrofitted to suit existing Lock Mandrel / Equalising Assemblies Multiple setting values (500 psi minimum - 3000 psi maximum) in 500 psi increments Large flow area after pump out in flow type / circulating applications Sheared plunger retained within the sump of Pump Open Sub eliminating unnecessary well debris Minimising wireline runs Can be sheared out even if debris restricts access to primary equalising facility by applying sufficient pressure Technical Information
To Suit SIM Lock 2 3/8 2 7/8 3 1/2 Actual OD 1.810 2.200 2.720 Pressure Rating *500 - 3,000 psi *500 - 3,000 psi *500 - 3,000 psi *500 - 3,000 psi

4 1/2 2.720 *Higher Shear Ratings Available on Request

Pump Open Sub Product Code: 300

info@peakwellsystems.com www.peakwellsystems.com