Anda di halaman 1dari 8

IS : 8360 (Part

II) -1977

Indian Standard

(RePFmed 1992) ( Reaffirmed 1997 )

SPECIFICATION FOR FABRICATED HIGH DENSITY POLYETHYLENE ( HDPE ) FITTINGS FOR POTABLE WATER SUPPLIES
PART II SPECIFIC REQUIREMENTS FOR 90 TEES ( Second Reprint JANUARY 1998 )

UDC

621.643.4.062.3:[678.742.2-JX596.115

@ Copyright 1977 BUREAU


hlANAK

OF
BHAVAN,

INDI~AN

STANDARDS

9 BAHADUR SHAH ZAFAR MARG NEW DELHI 110002

Gr 2

May 1977

IS : 8360 ( Part II ) - 1977

Indian Standard

(R-m--2)

SPECIFICATION FOR FABRICATED HIGH DENSITY POLYETHYLENE ( HDPE ) FITTINGS FOR POTABLE WATER SUPPLIES
PART
Sanitary

II

SPECIFIC

REQUIREMENTS Sectional

FOR 90 TEES Committee, BDC 3

Appliances

and Water Fittings


Bombay

Chairman
SHRI V. D. DESAI

Rcprexenting Municipal-Corporation

Members
Ministry of Health ADVISER SHRI B. B. Rau ( Allen& ) Indian Iron 8t Steel Co Ltd, Calcutta SIIEI H. R. BADYAL SHRIX. D. BISWAS ( Alternate ) Ceot~lor~~ildig Research Institute SHRI S. P. CHAKRABARTI
0 SHRI S.K.SIiAItMA

( CSIR ),

Central Public Works Department, New Delhi CHIEF ENGINEER SUPERINTENDINO ENOINF,ER ( Allcrnalc ) Tamil Nadu Water Supply & Drainage Board CHIEF ENQINEER Madras U. P. Jal Nigam, Lucknow CHIEF ENGINEER SU~ERINTENDINCI ENQINEER( Alkrnata ) Municipal Corporation of Delhi CHIEF ENGINEER( WATER ) DRAINAGE ENCXNEER( Alternate ) Bombay Municipal Corporation CITY ENGINEER HYDRAULIC ENGINEER( Allcmafe ) Indian Institute of Architects, Bombay SHRI H. N. DALLAS National Test House, Calcutta LALA G. C. DAS Institution of Engineers ( India ), Calcutta SHRI T. R. DE Directorate General of Supplies & Diiposals SHRI M. T. KANSE Delhi Devrlopment Authority SHRI S. C. KAPOOR Central Glass & Ceramic Research Institute SKRI R. V. LELE ( CSIR ), Calcutta National Environmental Engineering Research PROF N. MAJUMDER Institute ( CSIR ), Nagpur SHRI J. M. DAVF: ( Allematc ) Directorate General of Technical Development SHRI R. N. MALLICK SHRI N. R. SRINI~ASAN ( Al&nate )

(Allcmafc)

( Conhuud on page 2 )
@

Cofivri/ht 1977

BUREAU OF INDIAN STANDARDS This publication is protected under the Indian Copyrighf Ad ( XIV of 1957 ) and reproduction in whole or in part by any means except with written permission of the publisher shall be deemed to be an infringement of copyright under the said Act.

IS I 8360 (Part II) - 1977 ( Continuedfrom page 1 )


Members SRRI R. M. MEHRA SHRI R. N. MUKEERJEE SRRI 8. K. NEOGI ( Altcmatc ) SHRI D. APPUKUTTAN NAYAR Bombay Calcutta Representing Potteries & Tiles Ltd, Bombay Metropolitan Planning Organization

Public Health Engineering Department, Government of Kerala, Trivandrum SHRI K. RA~MACHANDRAN( Al&mare ) Engineer-in-Chiefs Branch, Army Headquarters COL RAJ KUMAR SHRI I. S. BEDI ( Altarnatr ) Public Health Engineering Department, Government SHRI P. S. RAJVAN~AI of Rajasthan, Jaipur Ministry of Railways SHRI RANJIT SINGE National Buildings Organization, New Delhi DR A. V. R. RAO SHRI G. T. BHIDE ( AIternatc ) E. I. D. Parry Ltd, Madras SHRI P. JAQANATH RAO SRRI T. S. CHINTAMANI ( Alternate ) Public Health Engineering Department, Government SHRI J. L. SETH1 of Haryana, Chandigarh SHRI A. N. hkiANm4LE ( ~&raarr ) Ltd, & Industries Hindustan Sanitaryware SHRI R. K. SOMANY Bahadurgarh SERI V. S. BHATT ( A&mat6 ) DirectorGeneral,IS1 ( Ex-oficio Member ) SEXI D. AJITEA SIMHA, Director ( Civ Engg )

Assistant

SRRI S. P. M~aau Director ( Civ Engg ), IS1

Plastic

Pipes Subcommittee,
Bombay Municipal

BDC 3 : 8
Corporation

SERI K. D. MULEKAR Members

SHRI S. H. MHATRE ( AIternate to Ministry of Health ADVISEB SSIRI V. A. ANANDADO~S ( Alternate ) Calico Chemicals, DE B. R. C. ANAND Bombay SERI S. MITRA ( Aftemak ) Houss~ &&ban SBRI P. M. APTE SERI B. K. CMKRABARTP SBBI S. BEOC~THALINQA~ SESI H. R. BUTANX SHBI B. K. CHAWLA (

Shri K. D.

Mulekar )

Plastics

and

Fibres

Division, Ltd,

Development

Corporation

( Altimatr ) Public Health Engineering Department, of Keralal Trivandrum Garwan Plastta ( Pvt ) Ltd, Bombay

Government

,&mut#)
( Continued on page 6

IS t 8360 ( Part II ) - 1977

Indian Standard
SPECIFICATION FOR FABRICATED HIGH DENSITY POLYETHYLENE ( HDPE ) FITTINGS FOR POTABLE WATER SUPPLIES
-PART II SPECIFIC REQUIREMENTS FOR 90 TEES

0.

FOREWORD

0.1 This Indian Standard ( Part II ) was adopted by the Indian Standards Institution on 17 January 1977, after the draft finalized by the Sanitary Appliances and Water Fittings Sectional Committee had been approved by the Civil Engineering Division Council. 0.2 The fabricated HDPE fittings are used for connection, process, to HDPE pipes covered by IS : 4984-1972*. by welding

0.3 The requirements of fabricated HDPE fittings are covered in three parts of this standard. Part I of the series deals with the general requirements applicable to all fabricated HDPE fittings and specific requirements of different types of fittings are covered in separate parts of the standard. This Part II deals with the specific requirements for 90 tees. 0.4 For the purpose of deciding whether a particular requirement of this standard is complied with, the final values, observed or calculated, expressing the result of a test or analysis, shall be rounded off in accordance with IS : 2-1960t. The number of significant places retained in the rounded off values should be the same as that of the specified values in this standard.

1. SCOPE 1.1 This standard ( Part II ) lays down the requirements for manufacture, dimensions and tolerances and marking for fabricated HDPE 90 tees for potable water supplies. *Specification for high density polyethylene pipes ( first revision ) . tRules for rounding off numerical values ( revised ). 3
for potable water supplies

IS t 8360 ( Part II ) - 1977 2. REQUIREMENTS 2.1 General test and sampling 2.2 Manufacture The general requirements for material, sizes, shall conform to IS : 8360 ( Part I )-1977*. method of

2.2.1 A typical

illustration

of fabricated

90 tee is shown

in Fig.

1.

FIG

90 TEE

2.2.2
thereon

Laying Length shall comply

The overall laying length 5 and the tolerance with those given in Table 1 read with Fig. 1.

2.2.3 The outside diameters and wall thicknesses of pipes out of which YiWees are fabricated shall comply with those given in IS : 8360 ( Part I )*_ The wall thickness of a fabricated 90 tee shall not be less than that of the pipe to which it is to be welded. 3. MARKING

3.1 Each

fabricated information: a) Manufacturers

90 tee name

fitting

shall

be

marked mark,

with the following and

or identification

b) The size of the fitting and the appropriate class ( working pressure ) to which the pressure rating ofthe fitting corresponds.
*Specification for fabricated high density water supplies: Part I Gsneral requirements. polyethylene ( HDPL ) fittings for potable

TABLE 1 DIMENSIONS FOR LAYING LENGTH OF FABRIGATED 90 TEES ( C&uI82.2.2 aml Fig. 1 )
SIZE 900

TBEU,OPEBALL h%!IlIOblVOTH, z
(2) mm

(1) mm

20 25 32 40 !iO 63 75 90 110 125 140 160 180 200 225 250 280 315 355 400 450 500

so& 2
62.5 f 2 80* 2 m* 2 *f 2 94-s * 4 112-S& 4 135f 4 16!J* 4 181.5 f 4 210& 6 240f 6 270& 6 300& 6 537.5 f I3 3755 8 420 f 8 472-5 f .8 532.5 f 10 600 f 10 675 f 10 75OflO

-~ 3.1.1 Each

~-

fabricated

90 tee fitting

may also be marked with the

Standard mark. 3.1.2 The use of the Standard Mark is govered by the provisions of the Bureau of Indian Standards Act, 1986 and the Rules and Regulations made thereunder. The details of conditions under which the licence for the use of Standard Mark may be granted to manufacturers or producers may be obtained from the Bureau of Indian Standards.

IS t 8360 ( Part II ) - 1977


(

Conlinuedfrom page 2)
Members RepraSnfing Small Scale Plastics Pipes and Fittings Manufacturers* Association, Bombay TamMafr;u Water Supply & Drainage Board, S. S. CEXHEDA ENoINEEE

SHBI
CHIET

U. P. Jai Nigam, Lucknow CEIE~ ENQINEER SUPERINTENDIIO ENOIN~E~ ( Allcrnatc ) Municipal Corporation of Delhi Cm~v EN~INEEE ( WAT) DEPUTY CHIEJ ENGINE= ( WATER ) ( Altmnatr ) National Environmental Engineering SRRI J. M. DAVIC Institute, Nagpur SHRI R. PARAMAEI~AM ( Altrmatr ) EMC~lc~;teml ( Plastic ) Industries SIIRI S. K. DEY SHRI R. K. JAIN Cent;~ork~dlding Research Institute

Research (P

Ltd,

( CSXR ),

SHRI S. P. CHAKRABARTI ( Alfrmate ) City & Industrial Development Corporation Ltd, SHBI A. R. KAN~A Bombay National Chemical Laboratory ( CSIR ), Pune DE S. L. KAPUE Imperial Chemical Industries ( India ) Ltd, Calcutta &RI A. E. LADEABHOY in V. B. V. RAJAN ( Altrmate t nion Carbide India Ltd, Calcutta SHRI U. S. MAJM~NDAR SEEI S. P. KHIJRANA ( Alternate ) Directorate General of Technical Development Saar R. PARIKSHIT Central Public Works Department Sam G. S. RAO Ministry of Defcnce SHRI K. C. S. RAO MAJ S. K. A~~ARWAL ( Ahnate ) Polyolefins Industries Ltd, Bombay Soar: P. B.RAo Srwtr V. DOEA~AJ (Ahmate ) National Buildings Organization, New Delhi SEBI 0. P. RATEA Public Health Engineering Department, Government REPEE~UWTATIV~ of Haryana, Chandigarh Chemicals & Plastics ( India ) Ltd, Madras SEXI R. SIVAEAMAKRI~HNAN SEBI R. KALIDAE ( A&srmaI~) Wavin India Ltd, Madras SFIRI G. K. SEINIVASAN &RI K. R. RANGARAJAX? ( Ahmate )

BUREAU

OF INDIAN STANDARDS Y

Headquarters: Manak Bhavan, 9 Bahadur Shah Zafar Marg, NEW DELHI 110002 Telephones: 323 0131,323 3375.323 9402 Fax : 91 11 3234062,91 11 3239399, 91 11 3239382 Telegrams : Manaksanstha (Common to all Offices) Central Laboratory : Telephone Plot No. 20/9, Site IV, Sahibabad Industrial Area, Sahibabad 201010 Regional Central *Eastern Offices: 32376 17 8-77 00 32

: Manak Bhavan, 9 Bahadur Shah Zafar Marg, NEW DELHI 110002 : l/l 4 CIT Scheme VII M, V.I.P. Road, Maniktola, CALCUTTA 700054
Sector 34-A, CHANDIGARH 160022

337 86 62 60 38 43 23523 15

Northern : SC0 335336, Southern

: C.I.T. Campus, IV Cross Road, CHENNAI 600113

twestern : Manakalaya, E9, Behind Marol Telephone Exchange, Andheri (East), MUMBAI 400093 Branch Offices:: Pushpak, Nurmohamed Shaikh Marg, Khanpur, AHMEDABAD SPeenya Industrial Area, 1 st Stage, Bangalore-Tumkur BANGALORE 560058 Road, 380001

832 92 95

550 13 48 839 49 55 55 40 21 40 36 27 21 01 41 8-28 88 01 8-71 1996

Gangotri Complex, 5th Floor, Bhadbhada Road, T.T. Nagar, BHOPAL 462003 Plot No. 62-63, Unit VI, Ganga Nagar, BHUBANESHWAR Kalaikathir Buildings, 670 Avinashi Road, COIMBATORE Plot No. 43, Sector 16 A, Mathura Road, FARIDABAD Savitri Complex, 116 G.T. Road, GHAZIABAD 201001 781003 500001 751001 641037

121001

53/5 Ward No.29, R.G. Barua Road, 5th By-lane, GUWAHATI

541137 201083 37 29 25 21 68 76

5-8-56C, L.N. Gupta Marg, Nampally Station Road, HYDERABAD E-52, Chitaranjan Marg, C- Scheme, JAIPUR 302001 1171418 B, Sarvodaya Nagar, KANPUR 208005 Seth Bhawan, 2nd Floor, LUCKNOW 226001 Behind Leela Cinema, Naval

Kishore

Road,

23 89 23 52 51 71 26 23 05 32 36 35 621 17

NIT Building, Second Floor, Gokulpat Market, NAGPUR 440010 Patliputra Industrial Estate, PATNA 800013 Institution of Engineers (India) Building 1332 Shivaji Nagar, PUNE 411005 T.C. No. 14/l 421, University P. 0. Palayam, THIRUVANANTHAPURAM 695034

*Sales Cffice is at 5 Chowringhee Approach, P.O. Princep Street, CALCUTTA 700072 tSales Office is at Novelty Chambers, Grant Road, MUMBAI 400007 *Sales Office is at F Block, Unity Building, Narashimaraja Square, BANGALORE 560002

271085 309 65 28 222 39 71

Reprography Unit, BIS, New Delhi, India