Project
Date
Application Engineer
S 13-0075
00 Impeller material: IB: Zincfree bronze TDH m 27.5 25.0 22.5 20.0 17.5 15.0 12.5 10.0 7.5 5.0 2.5 0 0 Eff. % 90 80 70 60 50 40 30 20 10 0 40 80 120 TDH
15-Jul-13
00 Capacity Total Head Frequency Speed Voltage Density Rising Main : : : : : : : 140 m/h 15 m 60 Hz 3495 1/min 480 V 1030 kg/m G5
P P kW 25 20 15 P P 10 5 0 Q
160
200
240
280
m/h
NPSH
Curves are approximate, pump is guaranteed for one set of conditions acc. to EN ISO 9906 1999, Cl. 1 Guarantees are based on shop test when handling clear fresh water at a temperature not over 20 C Flowserve Hamburg GmbH - P.O.Box 70 13 20 - D-22013 Hamburg Subject to alterations
QN83-1a + M6-270-2
Project
Date
Application Engineer
Data Sheet
00
15-Jul-13
00
Pump Data
Shut Off Head max. Power Rated Power Efficiency opt. Eff. in Duty Point Q/Qopt NPSH Suction specific speed (SI Units)
Motor Data
Rated Power : 9.4 kW Rated Current : 18.4 A Phase Current : --Speed : 3495 1/min Eff. in Duty Point : 81.0 % Total Efficiency : 59.4 % Veloc. along Motor Surface (min.) : 0.20 m/s Motor cable : 1Fl 3 m 4x2.5
Construction
Rotation, viewed in flow direction Height of centre line Moment of inertia Pump Moment of inertia Motor Non-Return Valve Adapter max. Diameter of Unit Overall Length of Unit BU-Code Act. Voltage Drop max. diameter (w/o cable) Material max. rated about min. : --: --: 147 mm : CCW : --: 0.009 kgm : 0.007 kgm : G5 : --: 188 mm : 1188 mm
Load
1/2 3/4 1/1
Eff-M
0.760 0.800 0.815
Pow.-Fact.
0.575 0.685 0.755
70 % U rated
Starting / Rated Torque 0.6 Breakdown / Rated Torque --Starting / Rated Current 2.4 max. permitted starts per hour Filling w. drinking water Motor Curve No. Torque-Speed Curve Pump Motor Non-Return Valve Adapter extended cable : : : :
100 % U rated
1.4 2.8 5.1 20 No MK60015/1 MM60015/1
Weights approx.
: 31.4 kg : 53 kg : 16 kg : --: ---
Notes
The max. diameter of unit must be cross checked by all means for narrow wells! In case there is the danger of ochring with sedimantation on the outer surface of motor a modified layout of motor is necessary. In such cases contact Flowserve Hamburg GmbH. Guarantee acc. to IEC 60034 / VDE 0530 + EN ISO 9906 1999, Cl. 1
Attention! Rated power of motor must be checked!Veloc. along Motor Surface: 0.00 m/s (calculational)
Price ex works:
Delivery time:
Validity:
Pleuger
Version 6.6 (04.09)
QN83-1a + M6-270-2
Project
Date
Application Engineer
UB4-130074
00
15-Jul-13
00
d
e e e
Data of installation
Length Pump + Motor Length of motor Non-Return Valve Length Non-Return Valve Adapter Length Adapter Overall Length of Unit Diameter of Motor max. Diameter of Unit Motor cable extended cable Rising Main Height of centre line a b : : : e : : e : a + e: c : d : : : : f : g g 983 mm 664 mm G5 205 mm ----1188 mm 144 mm 188 mm 1Fl 3 m 4x2.5 --G5 ---
a b
g f
Pleuger
Version 6.6 (04.09)