AUTOMATION AND INTEGRATION SOLUTIONS for Electric Power Systems

IED Integration Event Monitoring, Collection, and Analysis Local HMI and Visualization Cybersecurity RTU Replacement Distribution Automation Remedial Action Schemes SCADA Asset Optimization

Making Electric Power Safer, More Reliable, and More Economical 1

About SEL
Schweitzer Engineering Laboratories has delivered solutions for over 25 years that make electric power safer, more reliable, and more economical. SEL invented the worlds first digital distance relay in 1984, revolutionizing fault location, event analysis, and protection. In 1999, south of Orlando, Florida, SEL implemented smart grid projects in the International Drive power grid to automatically sectionalize a faulted line and reconfigure the grid to restore service to unfaulted sectionsall within six cycles. Leading in wide-area monitoring, protection, control, and analysis, SEL has installed over 31,000 SEL synchrophasor phasor-measurement-ready relays around the world. We offer engineering services, providing professional consulting and turnkey solutions for utility, industrial, and commercial markets worldwide. We also offer specialized training through SEL University courses. Visit www.selinc.com/selu for more information and to register for courses.

Reliability
SEL designs and manufactures products for the worlds most challenging production environments to exceed all industry standards for temperature, shock, and electric stress. SEL products operate in a temperature range of 40 to +85C (40 to +185F). They withstand electrostatic shock up to 15 kV and are vibration/shock resistant up to 15 g. We rigorously test our equipment in real-world conditions, producing products that lead the industry in their ability to withstand harsh substation environments. Manufactured in Pullman, Washington, USA, SEL products exceed industry standards and come with a ten-year, no-questions-asked, worldwide warranty. Through a relentless focus on continual improvement, SEL achieves ever-increasing levels of quality, delivery, and service performance. Since 2004, in independent studies conducted by Newton-Evans Research Company, Inc., electric utilities have ranked SEL the North American leader in all categories surveyed, including technology, price, features, service, and security.

Renewable Energies Motor-Operated Air Break Switch Control

Distribution Substation Control Enclosure Advanced Metering Solutions

Transmission Substation Control Enclosure


Power Plant

Single-Phase Recloser Monitoring

Recloser Control Overhead Faulted Circuit Indicators

Advanced Metering Solutions

Feeder Monitoring Feeder Monitoring and Capacitor Bank Control Voltage Regulation Control Automated Pad-Mounted Switchgear
Factory

Underground Faulted Circuit Indicators

From the generating station to the end of a distribution line, SEL solutions make the electric power grid smarter by providing protection, communications, sensing, monitoring, security, and control.
2

Automation and Integration Over view


Today, SEL offers robust automation and integration solutions for your applications and is committed to leading with the best, most economical solutions. We offer technologies, products, systems, and services that address the entire application spectrum, from communicating with a single relay to integrating and automating the metering, control, reporting, and protection for a large system. In electrical substations, commercial sites, and generating, manufacturing, and processing plants, apply SEL microprocessor-based relays to protect the electrical system. Apply SEL networking, control, and communications solutions to integrate devices for data acquisition plus remote and local control. SEL relays, information processors, and systems support many architectures. SEL information processors include real-time automation controllers (RTACs), communications processors, and tough computers with appropriate software. Choose tough SEL computing and networking products that are far more reliable and robust than office or industrial computer equipment and ideal for protocol conversion, local human-machine interfaces (HMIs), event report collection, data concentration, and more. Many SEL relays include local, remote, and latched control switches and display points. With these features, you can replace or eliminate many external devices and associated panels, documentation, wiring, commissioning, testing, and maintenance. You benefit from reduced total cost, improved system reliability, and state-of-the-art protection, monitoring, and control. Information processors support external communications links, including the public switched telephone network for engineering access or dial-out alerts, private line connections to your SCADA system, and wide-area networks (WANs). Many SEL relays and controllers have integral protocols and ports for connection to networks. The SEL ICON provides the fiber-optic communications backbone. SEL products and services are components of complete SEL solutions for instrumentation, protection, reporting, monitoring, local and remote control, and automation.

Relays and Other IEDs

Station LAN

SEL-3620

Security Gateway Integrated Communications Optical Network

Integrated Communications Optical Network

Human-Machine Interface

Serial SCADA Link Encrypt Data

Serial SCADA Link

Dial-Up Data Link Encrypt Data Modem


SEL-3530

Tough Computer SatelliteSynchronized Clock


SEL-2407

SEL-3620

SEL-3354

SatelliteSynchronized Clock
SEL-2407

Security Gateway

Encrypt Data

Ethernet Switch

SEL-2725

SEL-3530

Information Processor Fiber-Optic Ethernet Interleaved ASCII and Binary Data for Most SEL Products, Noninterleaved for Others Dial-Up Voice Link
SEL-3010

Information Processor Remote I/O Module


SEL-2516
Other IED

Other IED

Relay

SEL-3373

SEL-2533

PDC
Relay
SEL-3530

Port Server
SEL-3610

Ethernet Switch

SEL-2725
SEL-2240

Event Messenger

Annunciator
SEL-751A

Relays, Controllers, and Other IEDs

Information Processor Copper Ethernet

SEL-551

RTU
SEL-2515

SEL-2516

Other IED

Copper Ethernet
SEL-2411

SEL-2440

Remote I/O Module

Remote I/O Module

Relay

Copper Ethernet Programmable Automation Controller

Relay

Discrete Programmable Automation Controller

Relays, Controllers, and Other IEDs

Relays, Controllers, and Other IEDs

Block diagram of typical utility communications infrastructure.

I E D I n te g ra t i o n
SEL information processors enable you to design and implement both simple and complex intelligent electronic device (IED) integration solutions. Supported peer-to-peer technologies include SELs patented Mirrored Bits communications and IEC 61850.

SEL Information Processors


With protocols, I/O, and easy-to-use interfaces, SEL information processors like the RTAC offer data acquisition, control, and automatic notification for both SEL and non-SEL IEDs. SELs newest information processor, the SEL-3530 Real-Time Automation Controller (RTAC), is the next generation in automation control. The RTAC features secure communications, advanced data concentration, high-speed logic processing, exible engineering access, and protocol conversion capabilities between multiple built-in client/server protocols. The RTAC also provides the tools necessary to easily integrate and concentrate information from the wide variety of microprocessor-based devices found in todays substations.
Engineering

Local HMI
SEL-3354

SEL Mirrored Bits Relays

DNP3, Modbus, IEC 61850 Encrypted Link EIA-232 Mirrored Bits Communications Links
SEL-3530

SEL-2725
Five-Port Ethernet Switch

SEL Switch

GOOSE Messaging

Protocol conversion and data concentration with local control.

SEL University offers WBT 3332 Configuring Logical Expressions Using the SEL-3332 Intelligent Server and SEL-3351 System Computing Platform.
4

IEC 61850 and GOOSE Messaging

Control Center

SEL products support IEC 61850 and GOOSE, allowing you to combine IEC 61850 technology, Engineering Ethernet networking, and SEL high reliability Office to perform station computing, automation, and control. Find out more about IEC 61850 and GOOSE messaging solutions, case studies, and technical papers on the SEL website at www.selinc.com/61850.
Relay 1 sends high-speed GOOSE messages to Relay 2. Relay 2 sends high-speed GOOSE messages to Relay 1.
SEL-2725
Five-Port Ethernet Switch

SCADA Master

Wide-Area Network
SEL-3354
Desktop PC

Local HMI
SEL451

SEL451-4

SEL-311L
SEL487B

SEL421

SEL-387

SEL-710

SEL-751A

SEL-387
Relay 1

SEL451
Relay 2

SEL-2411

Ethernet Switch

Use IEC 61850 GOOSE messages to communicate high-speed information between local relays or other devices on the local-area network (LAN). Examples include breaker position, breaker trip, interlocking, and load-shedding commands.

Display and control using operational data in IEC 61850 logical nodes via LAN for local HMI, and WAN for remote SCADA. Engineers use WAN to configure devices and to retrieve and analyze event reports and sequential events records.

SEL M i r r o r e d B i t s Communications
Mirrored Bits communications is an innovative, low-cost, relay-torelay communications technology that exchanges the status of eight internal logic points called Mirrored Bits, encoded in a digital message, between two devices. This patented technology opens the door to numerous integration applications that would otherwise require more expensive external communications equipment wired through contacts and control inputs. Integration applications for Mirrored Bits communications include line protection pilot schemes, remote device control and monitoring, relay cross-tripping, and more. Apply Mirrored Bits communications over radio channels for directional comparison protection schemes. This provides fast fault clearing and preserves transient and voltage stability at very low cost. For additional information on integrating your applications using Mirrored Bits, visit www.selinc.com/mirroredbits.
Source #1
3

Recloser

SEL-351R

52
1

Hospital (critical load)

MIRRORED BITS Communications


(up to 20 miles using SEL-3031)
1

Recloser

SEL-351R

52

Source #2

SEL-311C

Available Communications Paths

Fiber-Optic Wave Audio Radio

SEL-311C

Mirrored Bits communications recloser application.

SEL-3031
SEL Serial Radio Transceiver

SEL-3031
SEL Serial Radio Transceiver

Mirrored Bits communications transmitted over radio channels.

Event Monito r i n g , Co l l e c t i o n , a n d A n a l ys i s
In 1984, SEL invented the worlds first digital distance relay with a built-in fault locator, revolutionizing fault finding. Current SEL event reporting technology and software, such as the ACSELerAtor Analytic Assistant SEL-5601 Software, makes wide-area monitoring, collection, analysis, and control of power system data possible. Integrated systems with SEL synchrophasors take event analysis one step further by providing the ability to monitor power system disturbances in real time through angle 1750 measurements, modal analysis, and out-of-step detection. You can view time-synchronized events together using the SEL-5601 Software. SEL 1550 Line Trip uses the SEL-3378 Synchrophasor Vector Processor (SVP) to create real-time, wide-area monitoring, protection, automation, and control solutions. 1350
MW

Another outage in Florida on February 26, 2008, was quickly analyzed by engineers using an SEL integrated and synchronized solution. The engineers then used their synchronized solution to improve their models and prevent similar situations in the future. A NERC press release on the Florida outage stated that synchrophasors are like the MRI of the bulk power system.

System Separation
SEL-421

SEL-3378

Line Trip and Generation Drop

The magnitude of the Northeast power blackout on August 14, 2003, could have been prevented, and the data analyzed in minutes rather than months, by using an SEL integrated and synchronized event monitoring and analysis solution.

1600

Amplitude = 32.71 Damping Ratio = 8.9% Frequency = 0.263 Hz

1565

Amplitude = 16.74 Damping Ratio = 0.76% Frequency = 0.258 Hz

1600

Amplitude = 42.02 Damping Ratio = 3.22% Frequency = 0.232 Hz

MW

MW

1550

1545

MW t Negative Damping Ratio

1500

1150 0

1500

t Damping Ratio < 10%

1525

1400

t Damping Ratio < 3%

100

200

300

400

500

Seconds

Line tripping, loss of generation, and other system events cause power oscillations. Use the SVP to identify oscillations in the early stages and alert power system operators to potentially unstable operating conditions.

SEL University offers the following classes in event monitoring, collection, and analysis: WBT 101 Event Report Analysis Workshop WBT 102 Event Report Analysis Workshop for Distribution Relays CBT 102 Retrieving Event Reports for Technicians CBT 103 Analyzing Event Reports for Engineers

Local HMI a n d Vi s u a l i za t i o n
SEL IEDs and tough computers monitor the status of communications lines and logic controllers, summarizing power system data (MW, MVAR, voltage, and current) and interfacing with settings for power management and remedial action schemes. Display one-line diagrams, alarms, communications diagrams, and many other useful tools with the substation touchscreen. SEL remote I/O modules and alarm panels provide quick indication status and alarm annunciation. Connect to information processors and IEDs to gather data, perform operations, and display the information you want.

SEL tough computers support a wide variety of visualizations for local HMI.

Cy b e rse cu r i ty
Implement cybersecurity with substation-hardened products from SEL. SEL relays and information processors contain strong electronic access-control technologies to effectively secure your cyberassets. The SEL-3620 Ethernet Security Gateway secures all Ethernet communications between your private networks and interoperates with existing business IT and control systems over an Internet Protocol Security (IPsec) virtual private network (VPN). The SEL-3620 protects your private network from malicious traffic with an integrated firewall and strong authentication access control. The SEL-3025 Serial Shield, an EIA-232, bump-inthe-wire serial cryptographic transceiver, protects meters, protective relays, programmable logic controllers (PLCs), remote terminal units (RTUs), and computers. The SEL-3025 prevents unauthorized access, control, monitoring, and malicious attacks by authenticating and optionally encrypting all data along the communications path. Our tough computers are also used in security solutions for their inherent authentication, security management, IPsec IP filtering, encryption, logging, password protection, and authentication features. Combine SEL technology with your policies, procedures, and training for a complete solution. For more information, visit www.selinc.com/cybersecurity.

SEL employs a number of individuals with professional security certifications in different levels and roles, and works closely with universities to implement the most current security technologies.

Where Is the Network Vulnerable to Intrusion?


Wireless

Real-Time Protection
Dedicated Fiber, Wire, or Cable

Satellite

SCADA/Metering Communications
Remote Monitoring or Billing

SCADA Control Center


Telecom Network WAN Private or Public TCP/IP Network

Public Telephone Network

Remote Access
Engineering Access

SCADA/Remote Access

Substation or Generation Facility


Internet

SEL University offers: APP 3620 Sensible Cybersecurity Using the Ethernet Security Gateway COM 203 SEL Cybersecurity Best Practices for Critical Infrastructure
8

SEL ICON Integrated Communications Optical Network


IRIG-IN IRIG-IN IRIG-IN IRIG-IN

SEL-3620 Ethernet Security Gateway

0 362 SELLi nk
Engineering Access Cisco Device IT Access

DM

Lin

WA N

Pu bl ic

Et he

Substation

Pri vat eT

rn

et

SEL-3620 Ethernet Security Gateway

Re

SEL ICON Integrated Communications Optical Network

SEL-3354 Embedded Automation Computing Platform

Firewall

mo

0 362 SEL-

te Ac ces s

3610 SEL351 SEL351 SEL351 SEL-

SEL-3610 Serial Port Server

ACCESS

025 EL-3

SEL-3530 Real-Time Automation Controller (RTAC)

LA

Serial Relays

0 353 SEL7XX SEL-

DATA AGGREGATION

Power System Protection

SEL-3025 Serial Shield Other IEDs


D D

IED ZONE

7XX SEL-

Information Technology

Regulatory Compliance

r IE the er IE

SEL offers complete end-to-end cybersecurity solutions for critical infrastructure applications.

Oth

Password Management
Manage IED passwords quickly and efficiently. Using ACSELERATOR TEAM SEL-5045 Software, you may even manage multivendor IEDs with the TEAM scripting interface.

Centralized Logging
Integrate into existing log management systems using Syslog. Off-site log storage also means easier compliance with NERC CIP critical infrastructure event logging rules and regulations.

Scalability
SEL builds security from the system level. Whether you need to manage one substation or hundreds, we create manageable, scalable solutions that make your system easier to control. Zone 1: Access Supplies strong access control for protecting both Ethernet and serial data entering or exiting the electronic security perimeter. Creates a proxy for legacy devices, instantly improving security without firmware upgrades. Zone 2: Data Aggregation Provides strong access control through port-level security, configurable access levels on local and remote access, strong authentication, and secure protocols. Zone 3: IED or Process Provides user and administrative access with strong passwords, port enable/disable, and alarm contacts, informing appropriate systems of events or changes to settings.

SEL-3620
SEL-3620
SEL-3530

SEL-3025

3:14PM: Admin: Login Attempt... 3:15PM: Admin: Login Attempt... 3:16PM: Admin: Login Attempt... 3:17PM: Admin: Login Attempt... 3:52PM: Admin: Login Attempt...

SEL-3610

Other IED Other IED Other IED

SEL-351

High Availability at the Substation


Mirror user rights and permissions using an SEL-3354 Embedded Computer and Windows Server 2008. This allows personnel to continue accessing the substation as they normally would if the communications link to the main Active Directory server is not accessible.

Compliance
Examine what enters the electronic security perimeter (ESP) by visualizing routes, open ports, and services. Powerful, flexible access controls are centrally managed, and user-based access controls ensure that access to the substation is only provided at the level needed to accomplish the job.

Central Authentication
Query central directories, including Microsoft Active Directory, using Lightweight Directory Access Protocol (LDAP). System administrators can easily add and remove role-based accounts to specific devices from a central location.
Bob isnt in the local database. Is Bob an approved user?

SEL-3620

Im Bob. I need access to the SEL-3620.


SEL-3620

Yes, Bob is approved.

SEL-3620
SEL-3354

SEL-3530

SEL-3530

SEL-3610

SEL-3610

Other IED Other IED Other IED

SEL-351

Other IED Other IED Other IED

SEL-351

RTU Replace m e n t
Improve your systems reliability, reduce program development time, and simplify connectivity with RTU replacement solutions from SEL. SEL solutions use substation-hardened devices and are economical, dependable, and easy to use. The graphic to the right shows a typical RTU replacement scheme by SEL for monitoring and controlling switchgear equipment. Your application may require different I/O configurations. Set up your own solutions, or let SEL help you design custom solutions to meet your needs.

Local HMI

SCADA Master

DNP3
SEL-2240

SEL-3354

Ethernet

SEL-2240

Combine a exible network structure using copper or fiber Ethernet cables to integrate local and remote signals.

High-density modular I/O RTU solutions integrated directly with the SEL-3530 RTAC for rugged and exible monitoring and control.

Example RTU Replacement Solutions


Simplify system design and gain greater performance by using the SEL-2240 for high-density I/O applications. The SEL-2240 directly integrates with the SEL-3530 RTAC, making configuration a snap. Easily create an Ethernet network of SEL-2240 nodes. The EtherCAT protocol provides deterministic performance and 1 ms SER records.

Create RTUs of any size using IEC 61850 GOOSE networks.

Choose the RTAC and other devices as needed for RTU replacement. This product features an easy-to-use IEC 61131-3 interface and a locally embedded, deterministic logic engine that allows you to manage your collected data. Easily combine and configure an SEL-3354 Embedded Automation Computing Platform and SEL-2411 Programmable Automation Controller (PAC) to monitor and control your devices. Connect multiple IEDs and support legacy protocols to send information directly to SCADA. Improve communications by replacing pad-mounted switchgear RTUs with the IEC 61850-compatible SEL-2411 PAC and wireless Ethernet peer-to-peer communications. This solution allows you to improve your system by supporting remote automation with coordinated protection and autorestoration schemes. SEL University offers WBT 2411S RTU Replacement Using IEC 61850.
10

D istributi o n Au to m a t i o n
From analysis to implementation, SELs comprehensive distribution automation products enhance voltage and power quality optimization programs and improve reliability statistics for SAIDI, CAIDI, SAIFI, and MAIFI. Once implemented, the system will analyze, isolate, and restore power. SEL distribution automation systems using information processors and integrated IEDs enable you to supervise the restoration of alternative sources based on parameters you set with the information processor, such as abnormal circuit configuration, hot-line tags, nonreclose status, disabled supervisory control, or communications failure. SEL distribution automation schemes include the following: Normal/standby source transfer Main-tie-main scheme Automatic load restoration Automatic fault line sectionalizing Automatic reconfiguration for restoration Automatic source transfer
Distribution Automation Control System

SEL Products Enable Distribution Automation

Analyze

Restore

Isolate

Analyze and detect fault conditions Isolate the affected feeder section Restore power to unaffected sections

SEL-3354

SCADA

Comms

Circuit A

Circuit B

SEL Relay

CB J

CB H
Relay

SEL Relay

Relay Comms

Comms
SEL-651R SEL-651R

Since 1999, SEL has been implementing distribution automation solutions to automatically sectionalize a faulted line and reconfigure the grid to restore service to unfaulted sections, such as the one at International Drive, Orlando, Florida.

R5
Non-SEL Control Comms

R1

SEL-651R

Comms
SEL-351R

R4
Non-SEL Control

R2 R3

SEL-351R

Comms
SEL-651R

SEL-651R

Distribution automation control system architecture.


11

Re m e d i a l Ac t i o n Sc h e m es
SEL remedial action schemes (RAS) protect against blackouts and system instability, increase corridor capacity limits, increase reliability, respond automatically to system contingencies, and bring your system operation closer to its stability limits. With remedial action schemes from SEL, you can detect and automatically respond to multiple, consecutive system contingencies. Control thousands of contingencies and loads with high-speed Mirrored Bits communications or IEC 61850 GOOSE messages. Preserve system stability using intelligent, contingency-based actions, such as exible load and generation shedding. All loads and generation can be prioritized and shed only when necessary to satisfy the contingency. Remedial action schemes detect unstable power conditions and automatically take corrective action, such as system islanding, to avoid blackouts. Let SEL Engineering Services design a remedial action scheme for your system.
SEL Meter
SEL-734
SEL-421

Substation #1
SEL Remedial Action Scheme

VPN/Ethernet

SEL Relay

Substation #3
SEL-351S

SEL Relay

SEL-3354
Tough Computer
VPN/Ethernet

Leased Line/ Serial


SEL-2505

I/O Module

Substation #2
SEL-2505

SEL-2411

I/O Module

Programmable Automation Controller

Remedial action scheme system architecture.

12

SCADA
SEL information processors support standard as well as customized SCADA applications with real-time access and control. Use SEL information processors, such as the SEL-3354 Embedded Automation Computing Platform or the SEL-3530 RTAC, for SCADA RTU and IED data collection and connectivity. Create distribution management systems (DMS) to avoid service interruptions, restore power quickly, and manage load shedding, load ow, switch order, automatic voltage control, disturbance analysis, load management, and SER analysis. Create energy management systems (EMS) for automatic generation control, synchrophasor state analysis, state estimation, operator load ow, load management, contingency analysis, dispatcher load ow, and optimal power ow.

SCADA Master
Local HMI
SEL-3354

DNP3 LAN/WAN

GPS Clock
SEL-2407

Engineering Access

Modem

SEL-3530

SEL-3010

Event Messenger
SEL-651R

Phone

SEL-3031
Radio Recloser Control

Relay
Protection, Control, Reporting, I/O

SEL-2516
Digital I/O

SEL-2410

Digital Outputs, Analog Inputs, TimeTagged Digital Inputs

SCADA connectivity converts protocols and communicates necessary information.

13

A sset O pt i m i za t i o n
SEL information processors form the data backbone of a complete substation asset optimization system by collecting, sorting, and storing information before sending it to a system-wide database. SEL asset optimization solutions provide the secure, concise, and controlled data that asset and maintenance managers need. Optimize the life cycle of your assets by monitoring key health indicators, and improve maintenance scheduling, life cycle management, reliability programs, and power quality management. Continuous monitoring of transformer and circuit breaker operating conditions can help you evaluate wear, allowing you to schedule or avoid unnecessary maintenance, improve physical management of assets, and improve system loading. Cost-effective, data-driven maintenance schedules, allowed by SEL Asset Optimization, reduce maintenance costs, increase asset life, help engineers make informed decisions, and maximize engineering resources.
Circuit Breaker Station Batteries

Transformer RTD Module


SEL-2600

SEL- Transformer 487E Protection Relay

SEL-2800

SEL-2890

Fiber-Optic Transceiver

Ethernet Transceiver

Load, top-oil and hot-spot temperatures, and cooling stage data are provided by the individual SEL-487E Relays protecting each transformer.

SEL-3354
Tough Computer as Information Processor

SEL-3010

Event Messenger

Asset optimization monitoring and notification architecture.

An individual transformer thermal report and graph use relay data to show a 24-hour trend for the transformer top-oil and hot-spot temperatures accumulated history.
14

SEL Suppo r t a n d Tra i n i n g


We are ready to assist with all of your automation and integration needs. Let us help you find the right solution for your unique situation.

SEL Engineering Ser vices


For more information on how to implement these solutions and others, contact SEL, an SEL representative, or SEL Engineering Services. Learn more about SEL Engineering Services at www.selinc.com/ engineeringservices.

SEL University
We offer application and product-specific courses that meet your training needs. In addition to scheduled courses, SEL University offers on-site training, webbased training (WBT), and computer-based training (CBT). For more information, visit the SEL University website at www.selinc.com/selu.

15

2350 NE Hopkins Court Pullman, WA 99163 USA Tel: +1.509.332.1890 Fax: +1.509.332.7990 www.selinc.com info@selinc.com

LM00100-01 20110413