PTO Configurations - Test


SMCS - 1000-081; 1165-081 The tables that follow list the following information: Sequence of events, Action that is taken by the Operator of the PTO and Position of the controlling equipment. The positions produce the resultant engine RPM within a specific programmed limit. The following components are used in order to provide a demonstration of the interaction of different systems: Cruise Control On/Off switch, PTO On/Off switch, Set/Resume switch, Fast Idle On/Off switch and Accelerator Pedal. Most systems will require only some of the components. Note: (Fast Idle) is not available for the H/D engines.

The Programmable Engine Limits


Note: Before performing each test, reset the parameters to the factory defaults. This will ensure that a parameter that was used for one test is not active for another test. The parameters that are given in the tables must be programmed in order to perform the tests. The parameters that are given in Table 1 must be programmed in order to perform the following test. The tables have the rpm ranges for the Medium DutyEngines M/D ( 3126B, 3126E, C7, and C9). The tables also have the rpm ranges for the Heavy Duty Engines H/D ( C-10, C11, C-12, C13, 3406E, C15, C-15, C-16, and C-18). Table 1 Parameter Programming for the Programmable Engine Limits "PTO Configuration" "PTO Top Engine Limit" The PTO Top Engine Limit can be programmed anywhere between the Low Idle Speed and the Top Engine Limit. "PTO Cab Throttle RPM Limit" Cab Switches 2100 rpm 2000 rpm H/D PTO Top Engine Limit

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 2 de 34

"Low Idle RPM" "Idle RPM Limit"

700 rpm 600 rpm H/D 900 rpm 2460 rpm C7, 3126B, and 3126E engines 2350 rpm C9 2120 rpm H/D 1000 rpm

"Top Engine Limit"

"Fast Idle Engine RPM" This option is not used on H/D engines. Table 2 The Programmable Engine Limits Frame 1 Action that was taken by the Operator of the PTO

Controlling Equipment

Result

Resultant Engine RPM

The Cruise Control switch is OFF. The PTO switch is OFF. The Set/Resume switch is OFF. The Fast Idle switch is OFF. The Accelerator Pedal is not depressed.

Park the vehicle with the engine at idle.

The engine is at the programmed low idle rpm. Programmed low idle for H/D engines is 600 rpm.

700 rpm 600 rpm H/D

Table 3 The Programmable Engine Limits Frame 2 Action that was taken by the Operator of the PTO Resultant Engine RPM

Controlling Equipment

Result

The Cruise Control switch is OFF. The PTO switch is OFF. The Set/Resume switch is OFF. The Fast Idle switch is OFF. The Accelerator Pedal is fully depressed.

Fully depress the accelerator pedal.

The engine is limited by the programmed Top Engine Limit (TEL). The TEL in this instance is 2640 rpm. Programmed TEL for C9 engines is 2350 rpm. Programmed TEL for H/D

2640 rpm C7, 3126B, and 3126E 2350 rpm C9 2120 rpm H/D

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 3 de 34

engines is 2120 rpm. Table 4 The Programmable Engine Limits Frame 3 Controlling Equipment Action that was taken by the Operator of the PTO Result The engine is limited by the programmed TEL which is 2640 rpm. Programmed TEL for C9 engines is 2350 rpm. Programmed TEL for H/D engines is 2120 rpm. Resultant Engine RPM

The Cruise Control switch is ON. The PTO switch is OFF. The Set/Resume switch is in the Set position. The Fast Idle switch is OFF. The Accelerator Pedal is fully depressed.

Place the Cruise Control switch to the ON position. Place the Set/Resume switch to the Set position.

2640 rpm C7, 3126B, and 3126E 2350 rpm C9 2120 rpm H/D

Note: The PTO Top Engine Limit (PTO TEL) can be programmed anywhere between the Low Idle Speed and the Top Engine Limit. Table 5 The Programmable Engine Limits Frame 4 Controlling Equipment The Cruise Control switch is ON. The PTO switch is OFF. The Set/Resume switch is OFF. The Fast Idle switch is OFF. The Accelerator Pedal is released. Action that was taken by the Operator of the PTO Release the Accelerator Pedal. Release the Set/Resume switch from the Set position. Result Resultant Engine RPM

The engine is at the programmed idle RPM Limit which is 900 rpm.

900 rpm

Table 6 The Programmable Engine Limits Frame 5 Action that

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 4 de 34

Controlling Equipment

was taken by the Operator of the PTO

Result The engine will return to Low Idle RPM because a PTO rpm has not been set. The PTO On/Off switch will override the Cruise Control On/Off switch. The "PTO Vehicle Speed Limit" must be higher than the actual vehicle speed.

Resultant Engine RPM

The Cruise Control switch is ON. The PTO switch is ON. Turn the PTO The Set/Resume switch is On/Off switch OFF. The Fast Idle switch is to ON. OFF. The Accelerator Pedal is released.

700 rpm 600 rpm H/D

Table 7 The Programmable Engine Limits Frame 6 Controlling Equipment Action that was taken by the Operator of the PTO Result The engine is at the PTO TEL which is 2100 rpm. PTO TEL for H/D engines is 2000 rpm. Resultant Engine RPM

The Cruise Control switch is ON. The PTO switch is ON. The Set/Resume switch is in the Set position. The Fast Idle switch is OFF. The Accelerator Pedal is fully depressed.

Place the Set/Resume switch in the Set position and fully depress the accelerator pedal.

2100 rpm 2000 rpm H/D

Note: The PTO Top Engine Limit (PTO TEL) can be programmed anywhere between the Low Idle Speed and the Top Engine Limit. Table 8 The Programmable Engine Limits Frame 7 Action that was taken by the Operator of the PTO Resultant Engine RPM

Controlling Equipment

Result

The Cruise Control switch is ON. The PTO switch is ON. The Set/Resume switch is OFF. The Fast Idle switch is OFF. The Accelerator Pedal is released.

Release the Set/Resume switch. Release the accelerator pedal.

The engine will remain at the PTO TEL which is 2100 rpm. PTO TEL for

2100 rpm 2000 rpm H/D

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 5 de 34

H/D engines is 2000 rpm. Table 9 The Programmable Engine Limits Frame 8 Controlling Equipment Action that was taken by the Operator of the PTO Result The engine will return to the low idle rpm which is 700 rpm. Low idle rpm for H/D engines is 600 rpm. Resultant Engine RPM

The Cruise Control switch is OFF. The PTO switch is OFF. The Set/Resume switch is OFF. The Fast Idle switch is OFF. The Accelerator Pedal is released.

Turn the Cruise Control On/Off switch to the OFF position. Turn the PTO On/Off switch to the OFF position.

700 rpm 600 rpm H/D

Table 10 The Programmable Engine Limits Frame 9 Controlling Equipment The Cruise Control switch is OFF. The PTO switch is OFF. The Set/Resume switch is OFF. The Fast Idle switch is ON. The Accelerator Pedal is released. Action that was taken by the Operator of the PTO Turn the Fast Idle switch to the ON position and then release. The switch will automatically return to the OFF position when the switch is released. Result Resultant Engine RPM

The engine will accelerate to the programmed Fast Idle RPM which is 1000 rpm.

1000 rpm

Note: (Fast Idle) is not available for the H/D engines. Table 11 The Programmable Engine Limits Frame 10 Controlling Equipment Action that was taken by the Operator of the Result Resultant Engine

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 6 de 34

PTO The Cruise Control switch is ON. The PTO switch is OFF. The Set/Resume switch is OFF. The Fast Idle switch is OFF. The Accelerator Pedal is released. Turn the Cruise Control On/Off switch to the ON position. The engine remains at the programmed Fast Idle rpm which is 1000 rpm.

RPM

1000 rpm

Table 12 The Programmable Engine Limits Frame 11 Action that was taken by the Operator of the PTO Turn the PTO On/Off switch to the ON position. Resultant Engine RPM

Controlling Equipment

Result

The Cruise Control switch is ON. The PTO switch is ON. The Set/Resume switch is OFF. The Fast Idle switch is OFF. The Accelerator Pedal is released.

The engine returns to the programmed Low Idle rpm because a PTO rpm has not been set. The PTO On/Off switch will override the Fast Idle.

700 rpm

Table 13 The Programmable Engine Limits Frame 12 Controlling Equipment The Cruise Control switch is ON. The PTO switch is OFF. The Set/Resume switch is in the RESUME position. The Fast Idle switch is OFF. The Accelerator Pedal is released. Action that was taken by the Operator of the PTO Turn the PTO On/Off switch to the OFF position. Turn the Set/Resume switch to the RESUME position. The switch will release after the RESUME position. Table 14 The Programmable Engine Limits Frame 13 Result The engine will return to the Idle RPM Limit that was set in Frame 4. Resultant Engine RPM

900 rpm

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 7 de 34

Controlling Equipment

Action that was taken by the Operator of the PTO Turn the Fast Idle switch to the ON position and then release.

Result

Resultant Engine RPM

The Cruise Control switch is ON. The PTO switch is OFF. The Set/Resume switch is OFF. The Fast Idle switch is ON. The Accelerator Pedal is released.

The engine will accelerate to the programmed Fast Idle RPM, which is 1000 rpm. The Fast Idle rpm is set higher than the Idle rpm. The Fast Idle rpm overrides the Cruise Control.

1000 rpm

"Fast Idle Operation"


Note: The Fast Idle option is not used on all engines. Table 15 illustrates the engine speed control by using the Fast Idle Enable Switch. The Fast Idle Enable Switch is a dash mounted switch. The switch is standard in GMC and Chevrolet Medium Duty Trucks. The switch is optional in all other chassis. The "Fast Idle Engine RPM 1" parameter provides one set speed above Low Idle operation. The "Fast Idle Engine RPM 2" parameter provides an additional set speed above Low Idle operation. NOTE: The programmed value for the "Fast Idle Engine RPM 1" can be overridden by using the accelerator pedal that is in the cab. Once the programmed value is overridden, the new value is used until the ignition key is turned OFF. Press the accelerator pedal to the new speed and press the Fast Idle switch. This will override the "Fast Idle Engine RPM 1". The programmed value for the "Fast Idle Engine RPM 2" can not be overridden. The parameters that are given in Table 15 must be programmed in order to perform the following test. Table 15 Parameter Programming for "Fast Idle Operation" "PTO Configuration" "Low Idle RPM" "Fast Idle Engine RPM 1" "Fast Idle Engine RPM 2" OFF 700 rpm 1000 rpm 1500 rpm Table 16 "Fast Idle Operation" Frame 1 Action that was taken Resultant

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 8 de 34

Controlling Equipment

by the Operator of the PTO

Result The engine is at the programmed low idle of 700 rpm.

Engine RPM

The Fast Idle Switch is OFF. Start the engine. The Accelerator Pedal is released. Table 17

700 rpm

"Fast Idle Operation" Frame 2 Controlling Equipment Action that was taken by the Operator of the PTO Turn the Fast Idle switch to the ON position and then release. Result The engine will ramp up to 1000 rpm, which is the programmed Fast Idle Engine RPM 1. Table 18 "Fast Idle Operation" Frame 3 Controlling Equipment Action that was taken by the Operator of the PTO Turn the Fast Idle switch to the ON position and then release. Resultant Engine RPM Resultant Engine RPM

The Fast Idle Switch is ON. The Accelerator Pedal is released.

1000 rpm

Result

The Fast Idle Switch is ON. The Accelerator Pedal is released.

The engine will then ramp up to 1500 rpm. 1500 rpm is the programmed Fast Idle Engine RPM 2. Table 19

1500 rpm

"Fast Idle Operation" Frame 4 Controlling Equipment Action that was taken by the Operator of the PTO Result Resultant Engine RPM

The Fast Idle Switch is

Turn the Fast Idle switch The engine will return to

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 9 de 34

ON. The Accelerator Pedal to the ON position and is released. then release. Table 20

the programmed Low Idle of 700 rpm.

700 rpm

"Fast Idle Operation" Frame 5 Controlling Equipment Action that was taken by the Operator of the PTO Result Resultant Engine RPM

In order to override the programmed "Fast Idle Engine RPM", the accelerator The Fast Idle pedal must be depressed until the desired Switch is ON. The rpm is achieved. Quickly toggle the Fast Accelerator Pedal Idle Enable Switch to the ON position is depressed. and then release. In this example, 1200 rpm is used.

The engine will go to 1200 rpm. The programmed Fast Idle Engine RPM 1 has been overridden. 1200 rpm NOTE: The programmed Fast Idle Engine RPM 2 can not be overridden.

Table 21 "Fast Idle Operation" Frame 6 Controlling Equipment Action that was taken by the Operator of the PTO Release the accelerator pedal. Resultant Engine RPM

Result

The Fast Idle Switch is OFF. The Accelerator Pedal is released.

The engine is now at the new Fast Idle Engine RPM, which is 1200 rpm. 1200 rpm is the temporary "Fast Idle Engine RPM".

1200 rpm

Engine Operation with "PTO Engine RPM Set Speed"


The parameter for the "PTO Engine RPM Set Speed" is useful only if one or two specific engine rpm above low idle is required. Program this parameter to the same value as the "PTO Top Engine Limit" if ONLY one specific engine rpm above low idle is required. This parameter determines the amount of engine rpm when the PTO On/Off switch is turned to the ON position. The parameter for the "PTO to Set Speed" must also be programmed to YES. If the "PTO to Set Speed" is programmed to NO, then this speed can be achieved by using the RPM Increase/RPM Decrease switch.

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 10 de 34

NOTE: The parameter for the "PTO Engine RPM Set Speed" can override the parameter for the "Idle/PTO Bump RPM". If the "PTO Engine RPM Set Speed" is programmed above 0 rpm, then the Set/Resume switch will function as the RPM Increase/RPM Decrease switch. This occurs when the PTO On/Off switch is ON. Example 1 illustrates PTO operation with two specific engine rpm above low idle. Example 1 also illustrates the "PTO Engine RPM Set Speed". In this example, the "PTO Engine RPM Set Speed" is for applications that require engine operation at low idle, at an intermediate rpm, and at the "PTO Top Engine Limit". Note: The PTO Top Engine Limit (PTO TEL) can be programmed anywhere between the Low Idle Speed and the Top Engine Limit. Example 2 illustrates PTO operation with one specific engine rpm above low idle.

Example 1
Table 22 Example 1 of the Parameter Programming for the "PTO Engine RPM Set Speed" "PTO Engine RPM Set Speed" "PTO Top Engine Limit" 1500 rpm 2100 rpm 2000 rpm H/D Table 23 Example 1 of the "PTO Engine RPM Set Speed" Frame 1 Controlling Equipment The PTO On/Off Switch is ON. The RPM Increase/Decrease switch is OFF. Action that was taken by the Operator of the PTO Turn the PTO On/Off Switch to the ON position and leave the throttle at the low idle position. Table 24 Example 1 of the "PTO Engine RPM Set Speed" Frame 2 Controlling Equipment Action that was taken by the Operator of Result Resultant Engine Result The engine will remain at low idle, which is 700 rpm. Low idle for H/D engines is 600 rpm. Resultant Engine RPM 700 rpm 600 rpm H/D

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 11 de 34

the PTO The PTO On/Off Switch is ON. The RPM Increase/Decrease switch is set to Increase. Turn the RPM Increase/Decrease switch to the Increase position. There should be no change in engine rpm. The PTO Engine RPM Set Speed is programmed and the engine will not respond until the RPM Increase/Decrease switch is released.

RPM

700 rpm 600 rpm H/D

Table 25 Example 1 of the "PTO Engine RPM Set Speed" Frame 3 Controlling Equipment Action that was taken by the Operator of the PTO Resultant Engine RPM

Result

The PTO On/Off Switch is ON. The RPM Increase/Decrease switch is released.

Release the RPM Increase/Decrease switch.

The engine will ramp up to the PTO Engine RPM Set Speed which is 1500 rpm. This will happen only after the RPM Increase/Decrease switch is released. Table 26

1500 rpm

Example 1 of the "PTO Engine RPM Set Speed" Frame 4 Controlling Equipment Action that was taken by the Operator of the PTO Turn the RPM Increase/Decrease switch to the Increase position. Result There should be no change in engine rpm. The PTO Engine RPM Set Speed is programmed and the engine will not respond until the RPM Increase/Decrease switch is released. Resultant Engine RPM

The PTO On/Off Switch is ON. The RPM Increase/Decrease switch is set to Increase.

1500 rpm

Table 27 Example 1 of the "PTO Engine RPM Set Speed" Frame 5

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 12 de 34

Controlling Equipment

Action that was taken by the Operator of the PTO

Result

Resultant Engine RPM

The PTO On/Off Switch is ON. The RPM Increase/Decrease switch is released.

Release the RPM Increase/Decrease switch.

The engine will ramp up to the PTO Top Engine Limit, which is 2100 rpm. This will happen only after the RPM Increase/Decrease switch is released. The PTO Top Engine Limit is 2000 rpm for H/D engines. Table 28

2100 rpm 2000 rpm H/D

Example 1 of the "PTO Engine RPM Set Speed" Frame 6 Controlling Equipment Action that was taken by the Operator of the PTO Result There should be no change in engine rpm. The PTO Engine RPM Set Speed is programmed and the engine will not respond until the RPM Increase/Decrease switch is released. PTO Engine RPM Set Speed is 2000 rpm for H/D engines. Resultant Engine RPM

The PTO On/Off Switch is ON. The RPM Increase/Decrease switch is set to Decrease.

Turn the RPM Increase/Decrease switch to the Decrease position.

2100 rpm 2000 rpm H/D

Table 29 Example 1 of the "PTO Engine RPM Set Speed" Frame 7 Controlling Equipment Action that was taken by the Operator of the PTO Resultant Engine RPM

Result

The PTO On/Off Switch is ON. The RPM Increase/Decrease switch is released.

Release the RPM Increase/Decrease switch.

The engine will ramp to the PTO Engine RPM Set Speed, which is 1500 rpm. This will happen only after the RPM Increase/Decrease switch is released.

1500 rpm

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 13 de 34

Table 30 Example 1 of the "PTO Engine RPM Set Speed" Frame 8 Controlling Equipment Action that was taken by the Operator of the PTO Turn the RPM Increase/Decrease switch to the Decrease position. Result There should be no change in engine rpm. The PTO Engine RPM Set Speed is programmed and the engine will not respond until the RPM Increase/Decrease switch is released. Resultant Engine RPM

The PTO On/Off Switch is ON. The RPM Increase/Decrease switch is set to Decrease.

1500 rpm

Table 31 Example 1 of the "PTO Engine RPM Set Speed" Frame 9 Controlling Equipment Action that was taken by the Operator of the PTO Resultant Engine RPM

Result

The PTO On/Off switch is ON. The RPM Increase/Decrease switch is released.

Release the RPM Increase/Decrease switch.

The engine will ramp to the programmed low idle rpm, which is 700 rpm. This will happen only after the RPM Increase/Decrease switch is released. Programmed low idle rpm for H/D engines is 600 rpm.

700 rpm 600 rpm H/D

Example 2
Table 32 Example 2 of the Parameter Programming for the "PTO Engine RPM Set Speed" "PTO to Set Speed" "PTO Engine RPM Set Speed" "PTO Top Engine Limit" Table 33 NO 1500 rpm 1500 rpm

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 14 de 34

Example 2 of the "PTO Engine RPM Set Speed" Frame 1 Controlling Equipment Action that was taken by the Operator of the PTO Result The engine will remain at low idle, which is 700 rpm. Low idle on H/D engines is 600 rpm. Resultant Engine RPM

The PTO On/Off Switch is ON. Turn the PTO On/Off The RPM Increase/Decrease switch Switch to the ON is OFF. position.

700 rpm 600 rpm H/D

Table 34 Example 2 of the "PTO Engine RPM Set Speed" Frame 2 Controlling Equipment Action that was taken by the Operator of the PTO Turn the RPM Increase/Decrease switch to the Increase position. Result There should be no change in engine rpm. The PTO Engine RPM Set Speed is programmed and the engine will not respond until the RPM Increase/Decrease switch is released. Resultant Engine RPM

The PTO On/Off Switch is ON. The RPM Increase/Decrease switch is set to Increase.

700 rpm 600 rpm H/D

Table 35 Example 2 of the "PTO Engine RPM Set Speed" Frame 3 Controlling Equipment Action that was taken by the Operator of the PTO Resultant Engine RPM

Result

The PTO On/Off Switch is ON. The RPM Increase/Decrease switch is released.

Release the RPM Increase/Decrease switch.

The engine will ramp up to the PTO Engine RPM Set Speed, which is 1500 rpm. This will happen only after the RPM Increase/Decrease switch is released.

1500 rpm

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 15 de 34

Table 36 Example 2 of the "PTO Engine RPM Set Speed" Frame 4 Controlling Equipment Action that was taken by the Operator of the PTO Turn the RPM Increase/Decrease switch to the Increase position. Result There should be no change in engine rpm. The PTO Engine RPM Set Speed is programmed. The engine will not respond until the RPM Increase/Decrease switch is released. Resultant Engine RPM

The PTO On/Off Switch is ON. The RPM Increase/Decrease switch is set to Increase.

1500 rpm

Table 37 Example 2 of the "PTO Engine RPM Set Speed" Frame 5 Controlling Equipment Action that was taken by the Operator of the PTO Result There should be no change in engine rpm. The PTO Top Engine Limit is programmed to the same rpm as the PTO Engine RPM Set Speed, which is 1500 rpm. Resultant Engine RPM

The PTO On/Off Switch is ON. The RPM Increase/Decrease switch is released.

Release the RPM Increase/Decrease switch.

1500 rpm

Table 38 Example 2 of the "PTO Engine RPM Set Speed" Frame 6 Controlling Equipment Action that was taken by the Operator of the PTO Turn the RPM Increase/Decrease switch to the Decrease position. Result There should be no change in engine rpm. The PTO Engine RPM Set Speed is programmed and the engine will not respond until the RPM Increase/Decrease switch is released. Resultant Engine RPM

The PTO On/Off Switch is ON. The RPM Increase/Decrease switch is set to Decrease.

1500 rpm

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 16 de 34

Table 39 Example 2 of the "PTO Engine RPM Set Speed" Frame 7 Controlling Equipment Action that was taken by the Operator of the PTO Resultant Engine RPM

Result

The PTO On/Off Switch is ON. The RPM Increase/Decrease switch is released.

Release the RPM Increase/Decrease switch.

The engine will ramp to the programmed low idle rpm, which is 700 rpm. This will happen only after the RPM Increase/Decrease switch is released. Programmed Low idle rpm for H/D engines is 600 rpm.

700 rpm 600 rpm H/D

"PTO to Set Speed Engine Operation"


The engine will accelerate to the "PTO Engine RPM Set Speed" when the "PTO to Set Speed" parameter is programmed to YES. The PTO On/Off switch must be ON. This is useful for applications that require only one specific engine rpm above low idle. Only one circuit is required. Table 40 Parameter Programming for "PTO to Set Speed Engine Operation" "PTO to Set Speed" "PTO Engine RPM Set Speed" YES 1500 rpm Table 41 "PTO to Set Speed Engine Operation" Frame 1 Controlling Equipment Action that was taken by the Operator of the PTO Result The engine is at the programmed low idle of 700 rpm. Programmed low idle rpm for H/D engines is 600 rpm. Resultant Engine RPM

The PTO On/Off switch is OFF. The Set/Resume switch is set to OFF.

Start the engine.

700 rpm 600 rpm H/D

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 17 de 34

Table 42 "PTO to Set Speed Engine Operation" Frame 2 Action that was taken by the Operator of the PTO Resultant Engine RPM

Controlling Equipment

Result

The PTO On/Off Switch is Turn the PTO On/Off ON. The Set/Resume switch Switch to the ON is set to OFF. position.

The engine will ramp to the programmed "PTO Engine RPM Set Speed".

1500 rpm

Multiple Speed PTO Operation by Using the PTO Engine RPM Set Speed "Input A" and PTO Engine RPM Set Speed "Input B"
JUL99 and Later Personality Modules The following is for the Medium Duty Engines. 3126B, 3126E, C7, and C9 PTO Engine RPM Set Speed A must be programmed to J1/P1:46 Input 7. PTO Engine RPM Set Speed B can be programmed to J1/P1:7 Input 4 or J1/P1:23 Input 19. A desired engine rpm can then be programmed for each input (PTO Engine RPM Set Speed A and PTO Engine RPM Set Speed B). The following is for the Heavy Duty Engines. C-10, C11, C-12, C13, 3406E, C15, C-15, C-16, and C-18 PTO Engine RPM Set Speed A or PTO Engine RPM Set Speed B must be programmed to any of the following terminals:
z

J1/P1:6 J1/P1:46 J1/P1:58 J1/P1:60

A desired engine rpm can then be programmed for each input (PTO Engine RPM Set Speed A and PTO Engine RPM Set Speed B). Perform the following functions so that the engine will proceed to the corresponding rpm that is programmed for the PTO Engine RPM Set Speed "Input A" or PTO Engine RPM Set Speed "Input B":
z

Turn the PTO On/Off Switch to the ON position. Turn the switch for the PTO Engine RPM Set Speed "Input A" or the PTO Engine RPM Set Speed

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 18 de 34

"Input B" to the ON position. If both switches are ON, the engine will proceed to PTO Engine RPM Set Speed "A" because the PTO Engine RPM Set Speed "Input A" has priority over "Input B". If switch "A" is then turned OFF, the engine will proceed to the programmed PTO Engine RPM Set Speed "B". If switch "A" is then turned ON, then the engine will proceed back to the PTO Engine RPM Set Speed "A". If both switches are in the OFF position, then the engine will return to Low Idle.

Example 1
Table 43 Example 1 of the Parameter Programming for the "Multiple Speed PTO Operation" by Using the PTO Engine RPM Set Speed "Input A" and PTO Engine RPM Set Speed "Input B" "PTO Engine RPM Set Speed A" "PTO Engine RPM Set Speed B" Table 44 Example 1 for the "Multiple Speed PTO Operation" by Using the PTO Engine RPM Set Speed "Input A" and PTO Engine RPM Set Speed "Input B" Frame 1 Action that was taken by the Operator of the PTO Resultant Engine RPM 1500 rpm 1200 rpm

Controlling Equipment

Result

The PTO On/Off Switch is OFF. The PTO Engine RPM Set Speed "A" is OFF. The PTO Engine RPM Set Speed "B" is OFF.

Start the engine.

The engine is at the programmed low idle of 700 rpm. Programmed low idle rpm for H/D engines is 600 rpm.

700 rpm 600 rpm H/D

Table 45 Example 1 for the "Multiple Speed PTO Operation" by Using the PTO Engine RPM Set Speed "Input A" and PTO Engine RPM Set Speed "Input B" Frame 2 Action that was taken by the Operator of the PTO Resultant Engine RPM

Controlling Equipment

Result

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 19 de 34

The PTO On/Off Switch is ON. The PTO Engine RPM Set Speed "A" is OFF. The PTO Engine RPM Set Speed "B" is OFF.

Turn the PTO On/Off Switch to the ON position.

The engine is at the programmed low idle of 700 rpm. The programmed low idle for H/D engines is 600 rpm.

700 rpm 600 rpm H/D

Table 46 Example 1 for the "Multiple Speed PTO Operation" by Using the PTO Engine RPM Set Speed "Input A" and PTO Engine RPM Set Speed "Input B" Frame 3 Controlling Equipment The PTO On/Off Switch is ON. The PTO Engine RPM Set Speed "A" is ON. The PTO Engine RPM Set Speed "B" is OFF. Action that was taken by the Operator of the PTO Turn the PTO On/Off Switch to the ON position. Turn the PTO Engine RPM Set Speed "A" to the ON position. Table 47 Example 1 for the "Multiple Speed PTO Operation" by Using the PTO Engine RPM Set Speed "Input A" and PTO Engine RPM Set Speed "Input B" Frame 4 Action that was taken by the Operator of the PTO Resultant Engine RPM Result Resultant Engine RPM

The engine is now at the programmed PTO Engine RPM Set Speed "A".

1500 rpm

Controlling Equipment

Result

The PTO On/Off Switch is ON. The PTO Engine RPM Set Speed "A" is ON. The PTO Engine RPM Set Speed "B" is ON.

The engine will remain at the programmed PTO Turn the PTO Engine RPM Set Speed Engine RPM Set "A". Speed "B" to the ON NOTE:Set Speed "A" position. has priority over Set Speed "B". Table 48

1500 rpm

Example 1 for the "Multiple Speed PTO Operation" by Using the PTO Engine RPM Set Speed "Input A" and PTO Engine RPM Set Speed "Input B"

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 20 de 34

Frame 5 Action that was taken by the Operator of the PTO Turn the PTO Engine RPM Set Speed "A" to the OFF position. Table 49 Example 1 for the "Multiple Speed PTO Operation" by Using the PTO Engine RPM Set Speed "Input A" and PTO Engine RPM Set Speed "Input B" Frame 6 Action that was taken by the Operator of the PTO Resultant Engine RPM Resultant Engine RPM

Controlling Equipment

Result

The PTO On/Off Switch is ON. The PTO Engine RPM Set Speed "A" is OFF. The PTO Engine RPM Set Speed "B" is ON.

The engine will go to the programmed PTO Engine RPM Set Speed "B".

1200 rpm

Controlling Equipment

Result

The engine is at programmed PTO The PTO On/Off Switch is ON. The Turn the PTO Engine Engine RPM Set Speed PTO Engine RPM Set Speed "A" is RPM Set Speed "A" "A". ON. The PTO Engine RPM Set to the ON position. NOTE: Set Speed Speed "B" is ON. "A" has priority over Set Speed "B". Table 50

1500 rpm

Example 1 for the "Multiple Speed PTO Operation" by Using the PTO Engine RPM Set Speed "Input A" and PTO Engine RPM Set Speed "Input B" Frame 7 Action that was taken by the Operator of the PTO Resultant Engine RPM

Controlling Equipment

Result

The PTO On/Off Switch is OFF. The PTO Engine RPM Set Speed "A" is ON. The PTO Engine RPM Set Speed "B" is ON.

Turn the PTO On/Off Switch to the OFF position.

The engine is at the programmed low idle of 700 rpm. The programmed low idle for H/D engines is 600 rpm.

700 rpm 600 rpm H/D

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 21 de 34

Table 51 Example 1 for the "Multiple Speed PTO Operation" by Using the PTO Engine RPM Set Speed "Input A" and PTO Engine RPM Set Speed "Input B" Frame 8 Action that was taken by the Operator of the PTO Resultant Engine RPM

Controlling Equipment

Result

The PTO On/Off Switch is ON. The PTO Engine RPM Set Speed "A" is ON. The PTO Engine RPM Set Speed "B" is ON.

Turn the PTO On/Off Switch to the ON position.

The engine is at programmed PTO Engine RPM Set Speed "A". NOTE:Set Speed "A" has priority over Set Speed "B".

1500 rpm

Example 2
The switches for the PTO Engine RPM Set Speed "A" or "B" can also be used in conjunction with other features that control engine speed during PTO operation. Set Speed "A" and Set Speed "B" have priority over all of the other features that are used to adjust engine rpm. Table 52 describes the interaction between the parameter for the PTO to Set Speed and the parameter for the PTO Engine RPM Set Speed. The parameter for the PTO to Set Speed is programmed to YES. Note: The feature for the "PTO Engine RPM Set Speed" is not available for the "Remote Throttle PTO Configuration". The PTO Engine RPM Set Speed "A" and the PTO Engine RPM Set Speed "B" are available for all three PTO configurations. Table 52 Example 2 for the Parameter Programming for the "Multiple Speed PTO Operation" by Using the PTO Engine RPM Set Speed "Input A" and PTO Engine RPM Set Speed "Input B" "PTO to Set Speed" "PTO Engine RPM Set Speed" PTO Engine RPM Set Speed "A" PTO Engine RPM Set Speed "B" Table 53 Example 2 for the "Multiple Speed PTO Operation" by Using the PTO Engine RPM Set Speed "Input A" and PTO Engine RPM Set Speed "Input B" Yes 1000 rpm 1500 rpm 1200 rpm

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 22 de 34

Frame 1 Action that was taken by the Operator of the PTO Resultant Engine RPM

Controlling Equipment

Result

The PTO On/Off Switch is OFF. The PTO Engine RPM Set Speed "A" is OFF. The PTO Engine RPM Set Speed "B" is OFF.

Start the Engine.

The engine is at the programmed low idle of 700 rpm. Programmed low idle for H/D engines is 600 rpm.

700 rpm 600 rpm H/D

Table 54 Example 2 for the "Multiple Speed PTO Operation" by Using the PTO Engine RPM Set Speed "Input A" and PTO Engine RPM Set Speed "Input B" Frame 2 Action that was taken by the Operator of the PTO Turn the PTO On/Off Switch to the ON position. Resultant Engine RPM

Controlling Equipment

Result

The PTO On/Off Switch is ON. The PTO Engine RPM Set Speed "A" is OFF. The PTO Engine RPM Set Speed "B" is OFF.

The engine is at the programmed PTO Engine RPM Set Speed of 1000 rpm.

1000 rpm

Table 55 Example 2 for the "Multiple Speed PTO Operation" by Using the PTO Engine RPM Set Speed "Input A" and PTO Engine RPM Set Speed "Input B" Frame 3 Action that was taken by the Operator of the PTO Resultant Engine RPM

Controlling Equipment

Result

The PTO On/Off Switch is ON. The PTO Engine RPM Set Speed "A" is ON. The PTO Engine RPM Set Speed "B" is OFF.

Turn the PTO Engine RPM Set Speed "A" to the ON position.

The engine is now at the programmed PTO Engine RPM Set Speed "A". NOTE: Set Speed "A" has priority over Set Speed "B". Set Speed "A" also has priority over the PTO to Set

1500 rpm

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 23 de 34

Speed. Table 56 Example 2 for the "Multiple Speed PTO Operation" by Using the PTO Engine RPM Set Speed "Input A" and PTO Engine RPM Set Speed "Input B" Frame 4 Action that was taken by the Operator of the PTO Resultant Engine RPM

Controlling Equipment

Result

The PTO On/Off Switch is ON. The PTO Engine RPM Set Speed "A" is ON. The PTO Engine RPM Set Speed "B" is ON.

Turn the PTO Engine RPM Set Speed "B" to the ON position.

The engine will remain at the programmed PTO Engine RPM Set Speed "A". NOTE: Set Speed "A" has priority over Set Speed "B". Set Speed "A" also has priority over the PTO to Set Speed.

1500 rpm

Table 57 Example 2 for the "Multiple Speed PTO Operation" by Using the PTO Engine RPM Set Speed "Input A" and PTO Engine RPM Set Speed "Input B" Frame 5 Action that was taken by the Operator of the PTO Resultant Engine RPM

Controlling Equipment

Result

The PTO On/Off Switch is ON. The PTO Engine RPM Set Speed "A" is OFF. The PTO Engine RPM Set Speed "B" is ON.

Turn the PTO Engine RPM Set Speed "A" to the OFF position.

The engine will go to the programmed PTO Engine RPM Set Speed "B". NOTE: Set Speed "B" has priority over the PTO to Set Speed.

1200 rpm

Table 58 Example 2 for the "Multiple Speed PTO Operation" by Using the PTO Engine RPM Set Speed "Input A" and PTO Engine RPM Set Speed "Input B" Frame 6

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 24 de 34

Controlling Equipment

Action that was taken by the Operator of the PTO

Result

Resultant Engine RPM

The PTO On/Off Switch is ON. The PTO Engine RPM Set Speed "A" is OFF. The PTO Engine RPM Set Speed "B" is OFF.

Turn the PTO Engine The engine is at RPM Set Speed "B" programmed PTO to the OFF position. Engine RPM Set Speed. Table 59

1000 rpm

Example 2 for the "Multiple Speed PTO Operation" by Using the PTO Engine RPM Set Speed "Input A" and PTO Engine RPM Set Speed "Input B" Frame 7 Action that was taken by the Operator of the PTO Resultant Engine RPM

Controlling Equipment

Result

The PTO On/Off Switch is OFF. The PTO Engine RPM Set Speed "A" is OFF. The PTO Engine RPM Set Speed "B" is OFF.

Turn the PTO On/Off Switch to the OFF position.

The engine is at the programmed low idle of 700 rpm. Programmed low idle for H/D engines is 600 rpm.

700 rpm 600 rpm H/D

Table 60 Example 2 for the "Multiple Speed PTO Operation" by Using the PTO Engine RPM Set Speed "Input A" and PTO Engine RPM Set Speed "Input B" Frame 8 Controlling Equipment The PTO On/Off Switch is ON. The PTO Engine RPM Set Speed "A" is OFF. The PTO Engine RPM Set Speed "B" is ON. Action that was taken by the Operator of the PTO Turn the PTO On/Off Switch to the ON position. Turn the PTO Engine RPM Set Speed "B" to the ON position. Result Resultant Engine RPM

The engine is at programmed PTO Engine RPM Set Speed "B".

1200 rpm

Programmable "Torque Limit"


Programming the parameter for the "Torque Limit" provides an engine torque limit for PTO operation or

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 25 de 34

other special situations. This feature should only be used for temporary protection of equipment. The programmable range for this parameter is 136 to 2720 Nm (100 to 2000 lb ft). The range is in 1 Nm (1 lb ft) increments. Programming the "Torque Limit" above the rated torque of the engine will not provide additional torque. The engine will operate using the normal torque curve whenever the normal torque is less than the programmed value of the "Torque Limit". The tables demonstrate the Torque Limit for the PTO. The tables also demonstrate the "Torque Limit" when the PTO is OFF. The "Torque Limit" operates when the PTO On/Off switch is ON. When the PTO On/Off switch is OFF and the Torque Limit Switch is ON, the "Torque Limit" will operate. Refer to Electronic PTO Installation and Applications Guide for Electronic Engines, "Cab Switches with Torque Limiting and Ignore Brake/Clutch Switch" for more information if the configuration for the PTO is programmed to Cab Switches. Refer to Electronic PTO Installation and Applications Guide for Electronic Engines, "Remote Switches with Torque Limiting and Ignore Brake/Clutch Switch" for more information if the configuration for the PTO is programmed to Remote Switches. The Torque Limit switch should be part of the system that requires the torque limit. Program the "Torque Limit" to the torque that is rated for the device that is protected by the Torque Limit. NOTE: The programmed torque level is an estimate. To achieve precise torque limiting, a chassis dynamometer may be required.

Illustration 1 (1) Engine Speed (RPM) (2) Torque (3) Normal Engine Torque Curve

g00621329

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 26 de 34

(4) Programmed Torque Limit

Illustration 2 (1) Engine Speed (RPM) (2) Torque (4) Programmed Torque Limit

g00621335

Operation of the "Torque Limit" With PTO On/Off Switch


Table 61 Parameter Programming "PTO Configuration" "Torque Limit" Cab Switches, Remote Switches, or Remote Throttle The value should be below rated torque of the engine. Table 62 Controlling Equipment The PTO On/Off Switch is OFF. Action that was taken by the Operator of the PTO Start the engine. Turn the PTO On/Off Result The normal engine torque is used. Refer to Illustration 43. The Torque Limit that has been programmed is

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 27 de 34

The PTO On/Off Switch is ON.

Switch to the ON position.

activated. This will reduce the torque that is available. Refer to Illustration 44.

Operation of the "Torque Limit" With A Torque Limit Switch


Table 63 Parameter Programming "PTO Configuration" "Torque Limit" Cab Switches, Remote Switches, or Remote Throttle The value should be below rated torque of the engine. Table 64 Action that was taken by the Operator of the PTO

Controlling Equipment

Result

The PTO On/Off switch is OFF. The Torque Limit switch is OFF. The PTO On/Off switch is OFF. The Torque Limit switch is ON.

Start the engine. Turn the Torque Limit Switch to the ON position.

The normal engine torque is used. Refer to Illustration 43. The Torque Limit that has been programmed is activated. This will reduce the torque that is available. Refer to Illustration 44.

"PTO Cab Throttle RPM Limit"


Note: The PTO Top Engine Limit (PTO TEL) can be programmed anywhere between the Low Idle Speed and the Top Engine Limit. The "PTO Cab Throttle RPM Limit" is active when the "PTO Configuration" is programmed to Cab Switches. The accelerator in the cab is always limited to low idle when the PTO Configuration is programmed to Remote Switches. The accelerator position sensor that is in the cab is limited to the value of the "PTO Cab Throttle RPM Limit" only when the PTO On/Off circuit is in the ON position. This is useful for applications with equipment that may be damaged by engine overspeed. This parameter has three programmable choices. The following items are the three programmable choices: Low Idle, Top Engine Limit and PTO Top Engine Limit.
z

If the "PTO Cab Throttle RPM Limit" is programmed to Low Idle, then the engine will not exceed the programmed Low Idle when the accelerator pedal is depressed. The PTO On/Off circuit must also be in the ON position. The accelerator pedal is ignored. If "PTO Cab Throttle RPM Limit" is programmed to the "Top Engine Limit", then depressing the accelerator pedal will allow the engine to achieve the programmed "Top Engine Limit".

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 28 de 34

If "PTO Cab Throttle RPM Limit" is programmed to the "PTO Top Engine Limit", then depressing the accelerator pedal will allow the engine to reach the programmed "PTO Top Engine Limit". The PTO On/Off circuit must also be in the ON position.

The next three tables describe each of the three options that are for this parameter.

"PTO Cab Throttle RPM Limit" That is Programmed to Low Idle


Table 65 Parameter Programming for "PTO Cab Throttle RPM Limit" That is Programmed to Low Idle "PTO Configuration" "PTO Top Engine Limit" "PTO Cab Throttle Limit" "Top Engine Limit" Cab Switches 2100 rpm 2000 rpm H/D Low Idle 2640 rpm C7, 3126B, and 3126E 2350 rpm C9 2120 rpm H/D Table 66 "PTO Cab Throttle RPM Limit" That is Programmed to Low Idle Frame 1 Controlling Equipment Action that was taken by the Operator of the PTO Resultant Engine RPM

Result

The PTO On/Off Switch is OFF. The Accelerator Pedal is fully depressed.

Fully depress the Accelerator Pedal.

The engine will not exceed the programmed Top Engine Limit of 2640 rpm for C7, 3126B, and 3216E engines. The Top Engine Limit for C9 engines is 2350 rpm. The Top Engine Limit for H/D engines is 2120 rpm. Table 67

2640 rpm C7, 3126B, and 3126E 2350 rpm C9 2120 rpm H/D

"PTO Cab Throttle RPM Limit" That is Programmed to Low Idle Frame 2

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 29 de 34

Controlling Equipment

Action that was taken by the Operator of the PTO

Result The engine will return to the low idle rpm of 700. Low idle rpm for H/D engines is 600 rpm.

Resultant Engine RPM

The PTO On/Off switch is ON. The Accelerator Pedal is fully depressed.

Turn the PTO On/Off Switch to the ON position.

700 rpm 600 rpm H/D

"Cab Throttle RPM Limit" That is Programmed to The "Top Engine Limit"
Note: The PTO Top Engine Limit (PTO TEL) can be programmed anywhere between the Low Idle Speed and the Top Engine Limit. Table 68 Parameter Programming for "Cab Throttle RPM Limit" That is Programmed to The "Top Engine Limit" "PTO Configuration" "PTO Top Engine Limit" "PTO Cab Throttle Limit" "Top Engine Limit" Cab Switches 2100 rpm 2000 rpm H/D TEL 2640 rpm C7, 3216B, and 3126E 2350 rpm C9 2120 rpm H/D Table 69 "Cab Throttle RPM Limit" That is Programmed to The "Top Engine Limit" Frame 1 Controlling Equipment Action that was taken by the Operator of the PTO Resultant Engine RPM

Result

The PTO On/Off Switch is OFF. The Accelerator Pedal is fully depressed.

Fully depress the Accelerator Pedal.

The engine will not exceed the Programmed Top Engine Limit of 2640 rpm for C7, 3126B, and 3126E. The Programmed Top Engine Limit for C9 engines is 2350

2640 rpm C7, 3126B, and 3126E 2350 rpm C9 2120 rpm H/D

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 30 de 34

rpm. Programmed Top Engine Limit of 2120 rpm for H/D engines Table 70 "Cab Throttle RPM Limit" That is Programmed to The "Top Engine Limit" Frame 2 Action that was taken by the Operator of the PTO Resultant Engine RPM

Controlling Equipment

Result

The PTO On/Off Switch is ON. The Accelerator Pedal is fully depressed.

The engine will remain at the Top Engine Limit of 2640 rpm for C9, 3126B, Turn the PTO On/Off and 3126E. Switch to the ON 2350 rpm for C9 position. The Top Engine limit is 2120 rpm for H/D engines.

2640 rpm C7, 3126B, and 3126E 2350 rpm C9 2120 rpm H/D

"Cab Throttle RPM Limit" That is Programmed to The "PTO Top Engine Limit"
Note: The PTO Top Engine Limit (PTO TEL) can be programmed anywhere between the Low Idle Speed and the Top Engine Limit. Table 71 Parameter Programming for "Cab Throttle RPM Limit" That is Programmed to The "PTO Top Engine Limit" "PTO Configuration" "PTO Top Engine Limit" "PTO Cab Throttle Limit" "Top Engine Limit" Cab Switches 2100 rpm 2000 rpm H/D PTO TEL 2640 rpm C7, 3126B, and 3126E 2350 rpm C9 2120 rpm H/D Table 72 "Cab Throttle RPM Limit" That is Programmed to The "PTO Top Engine Limit"

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 31 de 34

Frame 1 Controlling Equipment Action that was taken by the Operator of the PTO Resultant Engine RPM

Result

The PTO On/Off switch is OFF. The Accelerator Pedal is fully depressed.

Fully depress the Accelerator Pedal.

The engine will accelerate to the programmed Top Engine Limit of 2640 rpm for the C7, 3126B, and 3126E engines. Top Engine Limit of 2350 rpm for C9 The Programmed Top Engine Limit is 2120 rpm for H/D engines. Table 73

2640 rpm C7, 3126B, and 3126E 2350 rpm C9 2120 rpm H/D

"Cab Throttle RPM Limit" That is Programmed to The "PTO Top Engine Limit" Frame 2 Action that was taken by the Operator of the PTO Resultant Engine RPM

Controlling Equipment

Result

The PTO On/Off Switch is ON. The Accelerator Pedal is fully depressed.

Turn the PTO On/Off Switch to the ON position.

The engine will decelerate to the PTO Top Engine Limit of 2100 rpm. The PTO Top Engine Limit is 2000 rpm for H/D engines.

2100 rpm 2000 rpm H/D

"Idle/PTO RPM Ramp Rate"


The "Idle/PTO RPM Ramp Rate" determines the rate of acceleration and deceleration of the engine when the engine rpm is changing. This happens because of the actuation of the following items: Set/Resume switch, "Idle/PTO Bump RPM", "PTO to Set Speed" and parameters for the "PTO Engine RPM Set Speed". The "Idle/PTO RPM Ramp Rate" is not applicable to the acceleration and the deceleration of the engine due to an accelerator position sensor. The parameter is programmed in one rpm per second increments from 5 to 1000 rpm per second. This parameter should be programmed in order to match the application. Some applications have a reduced cycle time that is critical. This will provide reduced cycle times for those applications. Programming excessive ramp rates may stress the driven equipment.

"Idle/PTO Bump RPM"


https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 32 de 34

The "Idle/PTO Bump RPM" can be programmed to change the engine rpm when the Set/Resume switch is toggled. This parameter determines the change in rpm when the Set/Resume switch is toggled. If the PTO Engine RPM Set Speed is programmed to one rpm or above, then the parameter is overridden. Note: The "Idle/PTO Bump RPM" can not be used with the "Fast Idle" operation. The Fast Idle RPM is not set or changed with the Cruise Control Set/Resume switch. Table 74 Parameter Programming for "Idle/PTO Bump RPM" "PTO to Set Speed" "PTO Engine RPM Set Speed" "Cruise/Idle/PTO Switch Configuration" "Idle/PTO Bump RPM" "PTO Top Engine Limit" NO 0 rpm Set/Accelerate 400 rpm 1800 rpm Table 75 "Idle/PTO Bump RPM" Frame 1 Controlling Equipment Action that was taken by the Operator of the PTO Result The engine will remain at the low idle of 700 rpm. Low idle rpm for H/D engines is 600 rpm. Resultant Engine RPM

The PTO On/Off Switch is OFF. The Set/Resume Switch is OFF.

Start the engine.

700 rpm 600 rpm H/D

Table 76 "Idle/PTO Bump RPM" Frame 2 Controlling Equipment Action that was taken by the Operator of the PTO Turn the PTO On/Off Switch to Resultant Engine RPM

Result

The PTO On/Off Switch is ON. The Set/Resume

The engine will remain at the low idle of 700 rpm because the PTO

700 rpm 600 rpm H/D

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 33 de 34

Switch is OFF.

the ON position.

to Set Speed is programmed to NO. Table 77

"Idle/PTO Bump RPM" Frame 3 Controlling Equipment Action that was taken by the Operator of the PTO Result The engine will accelerate 400 rpm. This is the Idle/PTO Bump RPM value. The engine rpm is now 1100. The engine rpm will now be 1400 rpm for H/D engines. Resultant Engine RPM

The PTO On/Off switch is ON. The Set/Resume Switch is in the SET position.

Quickly toggle the Set/Resume Switch to the SET position and then release.

1100 rpm 1400 rpm H/D

Table 78 "Idle/PTO Bump RPM" Frame 4 Controlling Equipment Action that was taken by the Operator of the PTO Result The engine will accelerate 400 rpm. This is the Idle/PTO Bump RPM value. The engine rpm is now 1500. The engine rpm will now be 1800 rpm for H/D engines. Resultant Engine RPM

The PTO On/Off switch is ON. The Set/Resume Switch is in the SET position.

Quickly toggle the Set/Resume Switch to the SET position and then release.

1500 rpm 1800 rpm H/D

"PTO Vehicle Speed Limit"


The parameter for the "PTO Vehicle Speed Limit" is used to disable a "PTO Set Speed" when the vehicle speed exceeds the programmed limit. The PTO On/Off switch operates the "PTO Vehicle Speed Limit". The programmable range is 2 to 204 km/h (1 to 127 mph) in increments of one. By programming the parameter to one, the PTO Set RPM will be disabled while the vehicle is moving. The following item will cause disengagement of an active set rpm: exceeding the "PTO Vehicle Speed Limit". Note: A PTO that is driven by the transmission will produce a vehicle speed signal. Program the

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

3126E Truck Engine 9SZ00001-UP(SEBP3385 - 05) - Document Structure

Pgina 34 de 34

parameter for the "PTO Vehicle Speed Limit" to the maximum value of 204 km/h (127 mph) instead of disconnecting the vehicle speed circuit during the operation of the PTO. This will ensure that the "PTO Set Speed" will not be disabled due to vehicle speed. Note: In some instances, a false vehicle signal can be produced during the operation of the PTO due to the movement of the drive train. If the parameter for the "PTO Vehicle Speed Limit" is programmed to a very low value, then the operation of the PTO will abort when the false vehicle speed exceeds the programmed limit. It may be necessary to isolate the source of the false speed signal. The "PTO Vehicle Speed Limit" can also be programmed to a higher value.

"Cruise/Idle/PTO Switch Configuration"


This parameter will determine the ACCEL and DECEL function of both the Cruise Control On/Off switch and the PTO On/Off switch. The switch can be used for the Set/Resume switch or the switch can be held in position for a constant acceleration. The default positions follow: The Set position is the ACCEL position and the Resume position is the DECEL position. This can be changed by using the electronic service tool. Note: The Set Switch serves as the RPM Increase position and the Resume Switch serves as the RPM Decrease position under the following conditions: The PTO On/Off Switch is in the ON position. and The PTO Engine RPM Set Speed is programmed to one rpm or more. This is regardless of the programmed setting for the "Cruise/Idle/PTO Switch" configuration.

"Engine Monitoring"
An engine monitoring function is available for the engines. The parameter can be programmed to Off, Warning, Derate or Shutdown. Refer to the engine Operation and Maintenance Manual for additional information regarding this feature.

If Engine Monitoring is programmed to "Derate" or "Shutdown", and one of the monitored conditions is exceeded, then the engine will derate or shutdown. This should be considered especially if derating or shutting the engine down during PTO operation. This could present a problem for the vehicle or possible injury to the operator.

Copyright 1993, 2003 Caterpillar Inc. All Rights Reserved. Private Network For SIS Licensees.

Wed Sep 10 13:31:07 EST 2003

https://sis.cat.com/sisweb/servlet/cat.dcs.sis.controller.techdoc.CSSISFormatTechDocFor... 10/09/2003

Anda mungkin juga menyukai