Introduction
HHO Technology also known as Water Fuel Technology, is all about breaking the water molecule into Hydrogen and Oxygen using the electrical energy. Advanced Electrolysis technique used by researchers like Stan Meyer and others used pulsed DC current of 12VDC. It is proven by many researchers that square wave pulsed current helps to reduce heat generation during the electrolysis making the HHO gas production more efficient. DC Gated Pulse Generator is not an ordinary Pulse Width Modulator (PWM). Unlike PWM it gives you a complete control to vary the frequency, duty cycle, Amp and nature of wave form of the current being fed to the cell. Square Wave DC Gated Pulse Generator model # 12DC10A500C is based on Stan Meyer and Dave Lawtons pulsing circuit used for water fuel cell. Pls. refer Stan Meyers patent documents for WFC for original pulsing circuit. Our circuit is a modified version using advanced material and components technologies. We have incorporated several advanced features to make this circuit suitable for wider range of applications.

Schematic Diagram:

BATTERY 12VDC

DC GATED PULSE GENERATOR

Bubbler

To Engine

HHO CELL

www.HydroxyGarage.com, sales@HydroxyGarage.com Page 2

To Engine
Flow Meter BATTERY Control Valve
Pressure Gauge

12V
Bubbler

Humidity Seperator

DC Gated Square Wave Pulse Generator

Wave Forms of DC Gated Square Wave Pulsed Current HHO Generator Cell

www.HydroxyGarage.com, sales@HydroxyGarage.com Page 3

Parts:

Input Power 12VDC +Ve -Ve

Output Power 12VDC +Ve -Ve

Top View

Power ON/ OFF

Gating ON/ OFF

Range (1-2-3) Switch

Gate Frequency

Gating Section

Gate Mark/Space

Oscillator Section
Oscillator Frequency
Range (1-2-3) Switch

Oscillator Mark / Space

www.HydroxyGarage.com, sales@HydroxyGarage.com Page 4

Specifications:
DC Gated Pulse Generator (PWM) model # 12DC10A500C is a modified replication of Stan Meyer's Pulsing Circuit. It takes 12VDC supply from a car's battery and outputs 12VDC, 10A max, Square wave pulsed current. Frequency and duty cycle of the output current is variable making it convenient to adjust for the best performance. Frequency can be varied from 0 - 500 KHz and Duty Cycle from 0 100%.

Features

Input : 12VDC Output : 12VDC, 10 Amp max. Freq : Variable from 0 to 500 KHz. (Oscillator) max. Duty Cycle : 0 - 100% Gating : Selectable

Protection
Fuse Protected against over current >10 A. Protected against back EMF when connected with an inductive
load. Has in-built Fan and Heat-sink to protect circuit.

www.HydroxyGarage.com, sales@HydroxyGarage.com Page 5

Connection:
Requirements: 1. A Battery/ power supply with output voltage of 12VDC. 2. HHO Generator with 6 pairs of tubes or 6 cells if plates. You may also have a HHO Generator with 9 pairs of tubes or 9 cell if plates. 3. DC Gated Pulse Generator model # 12DC10A500C. 4. A Bubbler 5. Two sets of 5 long Red and Black, 12gauge electrical wire. 6. A good quality flexible tubes 1) 3 long 2) 5 DC Gated Pulse Generator model # 12DC10A500C is rated for input voltage at 12VDC. The device delivers constant Output Voltage at 12VDC. Step1: Please turn the DC Gated Pulse Generator to power OFF, Gating OFF and all knobs to minimum value i.e Turn Frequency and Mark/ Space knobs anti-clockwise and Range Switch to 1. Step 2: Please connect the Battery to Input terminal on the device. Positive (+ve) or Red terminal of battery should be connected to Positive (+ve) or Red terminal of DC Gated Pulse Generator. Similarly, Negative (-ve) or Black terminal of battery should be connected to Negative (-ve) or Black terminal of DC Gated Pulse Generator. Please remember that while working with DC current, connecting the device with correct polarity i.e. +ve to +ve and ve to Ve, is ESSENTIAL. Connecting the opposite polarity i.e. +ve to -ve and ve to +Ve, will damage the device permanently.

www.HydroxyGarage.com, sales@HydroxyGarage.com Page 6

Step 3: Connect output terminals of the DC Gated Pulse Generator to the terminals on the HHO generator cell. Remember to connect with right polarity. In a tube cell the outer tubes are connected to +Ve and inner tubes are connected to Ve of DC Gated Pulse Generator. In a plate cell, look for marking for +Ve and Ve polarity. Step 4: Connect output of HHO Cell to Bubbler. Bubbler is a safety device which acts as fire extinguisher in case of flashback. Output from the Bubbler should be injected into an engine with proper Gas Injection system by an engine expert.

Note: In certain cases, you may need to connect some devices like
Humidity Separator, Flow Meter, Pressure Gauge, etc.. Pls. take necessary precautions to connect them properly and make sure that there is NO LEAKAGE of gas. In any case, use the bubbler, before the HHO gas is delivered to engine or used in an application, as a best SAFETY measure. If required use two Bubblers.

www.HydroxyGarage.com, sales@HydroxyGarage.com Page 7

Operation:
OSCILLATOR SECTION :
Purpose of this circuit is to find Resonance Frequency.

Step 1: Turn the Power switch of DC Gated Pulse Generator to ON. Keep the Gating switch in OFF position. This will activate only the Oscillator section. Step 2: Turn the Mark/Space knob in Oscillator section clockwise, only few degrees from the minimum position. This is near to 100% duty cycle. Now, turn the Frequency knob in Oscillator section clockwise by few degrees from the minimum position and measure the current using a multi-meter. Measure the Frequency using an Oscilloscope or a frequency meter. Measure volume of HHO gas produced for the duration of 5 minutes. You can vary the duration as you wish.
Pulse Width Duration between 2 Pulses/ Duty Cycle

Pulse Width is Reduced. Duration between 2 Pulses/ Duty Cycle is constant.

www.HydroxyGarage.com, sales@HydroxyGarage.com Page 8

Again, turn the Frequency knob clockwise by few degrees and note the current. Again measure the Frequency and the volume of HHO gas produced for the duration of 5 minutes. Likewise, keep on increasing the frequency by turning the Frequency knob clockwise and measure current, Frequency and volume of HHO gas produced. Note the frequency at which you got best output of HHO Gas with least current. Step 3: Set the Frequency value derived from step 2 above. Now, turn the Mark/Space knob in Oscillator section clockwise by few degrees and note the current. Measure the Frequency using an Oscilloscope or a frequency meter. Measure volume of HHO gas produced for the duration of 5 minutes.
Pulse Width
Duration between 2 Pulses/ Duty Cycle

Pulse Width is constant. Duration between 2 Pulses/ Duty Cycle is reduced.

Keep on turning the Mark/Space knob clockwise and take the measurements. Purpose of the Oscillator Frequency is to find Resonance Frequency of the water in the cell.

www.HydroxyGarage.com, sales@HydroxyGarage.com Page 9

Oscillator section controls the nature of Square Wave pulses sent to the primary of the coil/ to cell i.e. pulse width and duty cycle. GATING SECTION: We use the gating frequency to tune into the mechanical Resonance of water that is between the tubes. We are turning on and off the voltage with the gating frequency to achieve the resonance of water between the tubes. Then we can use the duty cycle on the gating to control the gas production. Once the mechanical resonance is set, you need not change the frequency of the gating signal. It won't change once found. A gate pulse controls the number of pulses produced by the resonant frequency generator sent to the primary coil during a period determined by the gate frequency of the second pulse generator. So basically it controls the rate at which gas is produced and the formation of the pulse train. 1) Pls. read more explanation at: http://82.173.38.215/index.php/topic,1962.25.html and 2) A video showing gated pulses http://www.youtube.com/watch?v=ZKwKZ6V_gkw&feature=play er_embedded You will see the gated pulses in real.

www.HydroxyGarage.com, sales@HydroxyGarage.com Page 10

Fuse

Side View

Cooling Fan

View from Back

www.HydroxyGarage.com, sales@HydroxyGarage.com Page 11

WARNINGS : 1) This product is suitable for Input 12VDC only. 2) There is no Current Limiting in this device, hence you must manually monitor/ control the output current limit, else the device will fail permanently. HHO cell using a Catalyst are known to draw more current over a period of time. This can be dangerous for this device if exceeds max current. 3) We have provided a fuse as a security for over current, but it is found that fuses are not a reliable component. 4) There is a provision to safeguard the device against back EMF while using inductive load. But, one must gradually increase the inductive load to test its capability. 5) This product is EXPERIMENTAL only. We DONOT make any claims on increase in mileage, power, life of the engine, etc. whatsoever. As a researcher, we are just trying to develop/ test a new technology and as a fellow researcher or a techno-savvy individual, you are supporting our efforts. Pls. DONOT try this product if, you do not understand the risk associated. If you do, we shall not be liable for any claims and damages and payments. WARRANTY: 1) Free Replacement if returned within 1 months from Invoice. Shipping for returns to be paid by the Buyer. 2) Returns Warranty applicable only to units returned UNTEMPERED. 3) Please verify/ ask for Specifications, Prices, Availability/ Delivery before placing an order.