FE -E2-101 -11 FE -E2-101 -12 FE -V2-104 -16

0 0 0

ISSUED FOR PURCHASE ISSUED FOR PURCAHSE ISSUED FOR PURCHASE

05-07-2000 05-07-2000 05-07-2000

TVN TVN TVN

HBNS2-PS-IC-241-001 HBNS2-PS-IC-241-002 HBNS2-PS-IC-241-003

GENERAL

PROCESS CONDITIONS

METER

COUNTER

OPTIONS

PURCHASE

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55

Tag Number Service P&ID Number Line Number Area Classification

Equipment Number IEC

FE -E2-101 -11 SPLIT FEED EXCHANGERS TR 2 (SHELL SIDE) OUTLET HBNS2-PR-1238-1/1 12"-OL-A-2-1238002 E2-101A/B . Group II A Zone 2 Temp Class T3

Fluid Minimum Maximum Flow Normal Flow Operating Pressure Oper. Temperature Operating Specific Gravity Operating Viscosity Coefficient of Expansion Line Size Line Size Schedule Data Pipe I.D. Type of Element Inlet Size Outlet Size Connections Inlet Conn. Outlet Conn. Inlet Rating Outlet Rating Temperature & Pressure Rating Flow Rate Range Totalized Unit Enclosure Power Supply Outer Housing Main Body Cover Piston Element Materials Shaft of Blades Construction O-Ring Packing Bearing Bearings: Type & Material Type of Coupling Meter Size Register Type Totalizer Reset Capacity Set Stop Enclosure Shut-Off Valve Switch: Single / 2-Stage Temperature Compensator Transmitter Type Transmitter Output Air Eliminator Strainer: Size & Mesh Manufacturer Model Number

Crude oil Nm/h Nm/h bar-g cP in 419.9 48.88 Nm/h C

12.07 0.736 1.2 12 STD 12.

Liquid Turbine Flowmeter 6 in RF Flange ANSI Class 150 -46C TO 371C 54.5 - 749.5 N/A Explosionproof (IEC zone 2) 24V DC 304 SS/A105 (FLANGE) MFG STD 316 SS MFG STD (304 SS) MFG STD MFG STD Tungsten Carbide Magnetic Pickups 6 in NONE N/A N/A N/A

6 in RF Flange ANSI Class 150 Nm/h

N/A N/A N/A UNIVERSAL PREAMPLIFIER (TAG # FT-E2-101-11) PULSE OUTPUT N/A by others DANIEL #1401-3P

Notes: 1. Flowmeter shall be installed with minimum 20-pipe diameter upstream and 5-pipe diameter downstream. 2. Supplier to provide turbine meter flow range with meter factor calculations. INSTRUMENT SPECIFICATION 0 B A No. TVN TVN TVN By 05-07-2000 05-04-2000 16-03-2000 Date ISSUED FOR PURCHASE ISSUED FOR INQUIRY ISSUED FOR IDC Revision Turbine Flowmeter Sheet 1 Spec. No.: HBNS2-PS-IC-241-001 of 1 Rev.: 0

Code: 53

GENERAL

PROCESS CONDITIONS

METER

COUNTER

OPTIONS

PURCHASE

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55

Tag Number Service P&ID Number Line Number Area Classification

Equipment Number IEC

FE -E2-101 -12 2ND STG DESALTER TR 2 TO STABILIZER HBNS2-PR-1238-1/1 12"-OL-A-2-1238002 E2-101A/B . Group II A Zone 2 Temp Class T3

Fluid Minimum Maximum Flow Normal Flow Operating Pressure Oper. Temperature Operating Specific Gravity Operating Viscosity Coefficient of Expansion Line Size Line Size Schedule Data Pipe I.D. Type of Element Inlet Size Outlet Size Connections Inlet Conn. Outlet Conn. Inlet Rating Outlet Rating Temperature & Pressure Rating Flow Rate Range Totalized Unit Enclosure Power Supply Outer Housing Main Body Cover Piston Element Materials Shaft of Blades Construction O-Ring Packing Bearing Bearings: Type & Material Type of Coupling Meter Size Register Type Totalizer Reset Capacity Set Stop Enclosure Shut-Off Valve Switch: Single / 2-Stage Temperature Compensator Transmitter Type Transmitter Output Air Eliminator Strainer: Size & Mesh Manufacturer Model Number

Crude Oil Nm/h Nm/h bar-g cP in 522.2 48.89 Nm/h C

12.07 0.736 1.2 12 STD 12.

Liquid Turbine Flowmeter 6 in RF Flange ANSI Class 150 -46C TO 371C 54.5 - 749.5 N/A Explosionproof (IEC zone 2) 24V DC 304 SS/ A105 (FLANGE) MFG STD 316SS 304 SS (MFG STD) MFG STD MFG STD Tungsten Carbide Magnetic Pickups 6 in NONE N/A N/A N/A

6 in RF Flange ANSI Class 150 Nm/h

N/A N/A N/A UNIVERSAL PREAMPLIFIER (TAG # FT-E2-101-12) PULSE OUTPUT N/A by others DANIEL #1401-3P

Notes: 1. Flowmeter shall be installed with minimum 20-pipe diameter upstream and 5-pipe diameter downstream. 2. Supplier to provide turbine meter flow range with meter factor calculations. INSTRUMENT SPECIFICATION 0 B A No. TVN TVN TVN By 05-07-2000 05-04-2000 17-03-2000 Date ISSUED FOR PURCAHSE ISSUED FOR INQUIRY ISSUED FOR IDC Revision Turbine Flowmeter Sheet 1 Spec. No.: HBNS2-PS-IC-241-002 of 1 Rev.: 0

Code: 53

GENERAL

PROCESS CONDITIONS

METER

COUNTER

OPTIONS

PURCHASE

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55

Tag Number Service P&ID Number Line Number Area Classification

Equipment Number IEC

FE -V2-104 -16 HEATER FUEL GAS FILTER SUPPLY HBNS2-PR-1240-1/1 6"-FG-A-2-1881004 V2-104 . Group II A Zone 2

Temp Class T3

Fluid Minimum Maximum Flow Normal Flow Operating Pressure Oper. Temperature Operating Specific Gravity Operating Viscosity Coefficient of Expansion Line Size Line Size Schedule Data Pipe I.D. Type of Element Inlet Size Outlet Size Connections Inlet Conn. Outlet Conn. Inlet Rating Outlet Rating Temperature & Pressure Rating Flow Rate Range Totalized Unit Enclosure Power Supply Outer Housing Main Body Cover Piston Element Materials Shaft of Blades Construction O-Ring Packing Bearing Bearings: Type & Material Type of Coupling Meter Size Register Type Totalizer Reset Capacity Set Stop Enclosure Shut-Off Valve Switch: Single / 2-Stage Temperature Compensator Transmitter Type Transmitter Output Air Eliminator Strainer: Size & Mesh Manufacturer Model Number

Fuel Gas 2910 3.5 0.83 0.00978 6 STD 6.065 Nm/h Nm/h bar-g cP in Nm/h 48.89 C

Gas Turbine Flowmeter 6 in RF Flange ANSI Class 150 118.8 - 4485 N/A Explosionproof (IEC zone 2) 24V DC A216 WCB MFG STD MFG STD ALUMINUM MFG STD MFG STD 440 SS Magnetic Pickups 6" NONE N/A N/A N/A

6 in RF Flange ANSI Class 150 Nm/h

N/A N/A N/A UNVERSAL PREAMPLIFIER (TAG # FT-V2-104-16) PULSE OUTPUT N/A by others DANIEL #2011-DHC

Notes: 1. Flowmeter shall be installed with minimum 20-pipe diameter upstream and 5-pipe diameter downstream. 2. Supplier to provide turbine meter flow range with meter factor calculations. INSTRUMENT SPECIFICATION 0 B A No. TVN TVN TVN By 13-07-2000 05-04-2000 17-03-2000 Date ISSUED FOR PURCHASE ISSUED FOR INQUIRY ISSUED FOR IDC Revision Turbine Flowmeter Sheet 1 Spec. No.: HBNS2-PS-IC-241-003 of 1 Rev.: 0