Anda di halaman 1dari 3

CONTRACT DATA SHEET

CONTRACT NO. 0663 PURCHASER CSEB KORBA WEST TPP EXTN PLANT NAME STAGE III 1 x 500 MW, CONS. ENGG ---

Contract Date: April, 2008

Utility

PROPOSED FUEL FC% 24.0

Sub Bituminous Coal M% 14.0 Ash% 41.0 S% 0.28

Ash Fusion Temp 1400oC

HHV Kcal/kg 3300

Grindability (HGI) 55

VM% 21.0

FUEL BURNING EQUIPMENT TYPE Main Burners MAKE & NOS. CONTROL CAPACITY DISPOSITION FURNACE Tilting Tangential BHEL, 40 Air Damper 55 x 106 kcal/hr. Corners Stabilisation Burners Low NOx BHEL, 20 Air Damper 18.51 x 106 kcal/hr. Corners MILLS Pressure Type: XRP 1003 Make & Nos.: BHEL, 10 Capacity: 65.0 t/h @ DC Motor kW : 525 Speed (RPM) : 1000 System: Cold PA

Type: Balanced Draft Furnace with Fusion Welded Water Walls DEPTH 16115 mm Volume m3 : 17599 (as per specification) Fuel Heat Input: 1234.2x106 kcal/hr @ BMCR DC Drum Design: 209 kg/cm2 (g) Super heater outlet: 178.0 kg/cm2 (g) - BMCR

WIDTH 19177 mm

BOILER

Controlled Circulation with Rifled Tubing, (CC+), Radiant Reheat, Dry Bottom, Top Supported

DESIGNATION:

19177 16115
SUPER HEATER

301 51 235 51

CC +

Stage: 1 H. S. Area m2
2

Type: LTSH Horizontal and Pendant Stage: 2

8661

Total H.S. m2 11561

Type: SH Division Panellette (Tube Projected) Stage: 3 Type: SH Finish Platen (Tube Projected)

1415

1485

ATTEMPERATOR

Type: Spray Type: Stage-I: Pendant Platen, Stage-II: Pendant Spaced

No. of Stages: Single Stage Total: H.S. m 8620

Medium of Spray: Feed Water Control: Burner Tilt and Excess Air

REHEATER

Sheet 1 of 3

CONTRACT DATA SHEET


CONTRACT NO. 0663 ECONOMISER Type: Plain Tube Type: Bisector AIR HEATER Primary: 27.5 VI 2000 Secondary: 30.0 VI 2000 Total H. S. m2 : 15200 Total: H.S. m Nos.:
2

Contract Date: April, 2008 No. of Blocks: 3 Motor kW Make:


Primary:11.0 Secondary:18.5

Primary:40070 Secondary:62740 Primary: 2 Nos. Secondary: 2 Nos.

BHEL

BOILER AUXILIARIES FANS FD FAN PA FAN ID FAN Type AXIAL


AP1-26/16 Make

Flow
Nos

Pressure mmwc

Temp
o

m /s 277

Drive

Speed rpm 980

Motor kW 1430

Control

BHEL

410

50

Motor

AXIAL
AP2-20/12

BHEL

193

1195

50

Motor

1480

2800

RADIAL NDZV 47 SIDOR

BHEL

609

490 Make BHEL

150

Motor No.s 88

580

4000 Medium Steam

Blade Pitch Control Blade Pitch Control Inlet Damper Control + VFD

SOOT BLOWERS FURNACE SH PANEL SH PLATEN LTSH REHEATER ECONOMISER DUST COLLECTOR FAA-9x45M2x92150-2 PIPE LINES SIZE mm x mm No. OFF MATERIAL

TYPE Wall Blowers

Long Retractable Soot Blowers

BHEL

40

Steam

Make

Nos.

Dust Concentration at inlet 74.0 g/Nm3 HOT REHEAT 711.0 x 25 2 SA 335 P91

Flue Gas Flow 617.1 Nm3/Sec COLD REHEAT 660 x 22 2 SA 106 GR.C

Combined Efficiency %
(One field out of service) 99.932

BHEL

MAIN STEAM 406.4 x 38 2 SA 335 P91

FEED WATER 508 x 64 1 SA 106 GR.C

Sheet 2 of 3

CONTRACT DATA SHEET


CONTRACT NO. 0663 BOILER MOUNTINGS Location Type 1750 WB Drum 1740 WB Safety Valves SH Outlet SV ERV 1740 WD 1538 VX-10W BHEL BHEL 2 2 5 Make
No.

Contract Date: April, 2008

Set Pr. Kg/cm2(g) 209.0, 211.1 213.2, 213.2 215.3, 215.3 188.5, 188.5 185.5, 185.5,186.6, 186.6, 186.6

Size in / out (mm)

76.2/152.4 76.2/152.4 63.5/101.6

Inlet RH Outlet

1786 WB 1786 WE 1525 VX DWLG EWLI

BHEL BHEL Yarway BHEL

4 4 4 2 4

52.4, 52.4, 54.0, 54.0 48.4, 48.4, 49.9, 49.9 47.4, 47.4, 47.9, 47.9 -

152.4/254 152.4/203.2 152.4/203.2 21 VISIBILITY BHELVISION

Water Level Indicator

Drum

MAIN PARAMETERS FUEL UNIT GENERATOR Superheat Reheat Total Heat Output of System (Q Duty) Pressure at Super Heater Outlet Temperature at SH Outlet Pressure at Reheater Inlet Temperature at Reheater Inlet Pressure at Reheater Outlet Temperature at Reheater Outlet Feed Water Temperature (ECO Inlet) Ambient Air Temperature Combustion Air Temperature (Secondary) Fuel Quantity FLOW Air Quantity (Total Combustion Air) FLUE GAS Temp. of Gas at Boiler Exit (Corrected) Temp. of Recirculation Gas Quantity of Recirculation Gas STEAM MW t/h t/h Mkcal/h kg/cm2(g) o C kg/cm2(g) o C kg/cm2(g) o C o C o C o C t/h t/h
o o

DESIGN COAL 100% 100% BMCR TMCR 500 1590.0 1457.9 1358.0 1302.1 1046.6 969.7 178.0 176.6 540 540 45.02 43.19 337.5 337.1 42.37 40.65 568 568 254.5 253.4 27 27 311 305 374 347 2024 126 84.84 1855 125 84.85

50% TMCR 250 755.4 656.8 538.6 171.1 540 21.45 310.7 20.17 568 219.4 27 262 193 1033 114 84.74

C C

t/h %

Efficiency Based on HHV (BSEN 12953-15:2003)

Sheet 3 of 3