Range of Application Medium Water, compressed air, medium and light fuel oils, kerosene, petroleum with less than 15% aromatic content. Not suitable for gaseous mediums below 0.5 bar, steam, heavy oils and benzole Operating pressure Technical Data Operating temperature Water up to 75 C (short term up to 90 C) Compressed air and other mediums up to 70 C Opening pressure Connection sizes Materials q q q q q q Brass housing Brass union nut High quality synthetic material disc guide and disc NBR lip sealing ring Stainless steel spring High grade synthetic material blanking plugs Approximately 0.05 bar
1 2
Construction The non return valve comprises: q q q q q q q Housing with test and drain taps (1/2" device with test tap only) Non return valve insert Union connector with female thread Blanking plugs Disc guide Spring Disc with lip sealing ring
/ " - 2"
Subject to change
02/00
13
v v
h Rp
Connection sizes Rp Weight (Approx. kg) Dimensions (mm) L h sw Test and drain plugs R* kvs-value Nominal flow rate (m3/h) at Dp = 0.15 bar
* Test plug only
14
Honeywell AG . Mosbach
v v
/"
1 4
v v
L " 0.2 65 29 27 1/4" 4.5 1.7
1/2
3/4
Subject to change
02/00
Installation Example
Installation Guidelines q If possible install in horizontal pipework with test and drain plugs downwards This position is best for draining q Fit isolating valves Isolating valves provide optimal serviceability q Ensure good access Simplifies maintenance and inspection q For systems with water meters, install immediately afterwards (permitted by draft Euronorm) Protects against backflow from water systems
Typical Applications Type RV 280 non return valves are suitable for use as a safety device on any water installation as specified in DIN 1988, Part 4. They can be used within the scope of their specification. The following are some typical uses for RV 280 non return valves: q In central water supply systems q After a water meter q As a safety device up to risk Class 2 of DIN 1988, Part 4 q Downstream of pumping installations q Upstream of water heating installations
Flow Diagram
[m3/h]100 80 60 40 30 20 10 8 6 4 3 2 1 0,8 0,6 0,4 0,3 0,2 0,1 0,3 0,03 0,4 0,04 0,5 0,6 0,7 0,8 0,05 0,06 0,07 0,08 1 0,1 1,5 0,15 2 0,2 3 0,3 4 0,4 5 0,5 8 6 7 0,6 0,7 0,8 10[mWS] 1[bar
Pressure drop Dp
Subject to change 02/00 Honeywell AG . Mosbach
15
Part number 5534900 5535100 5531500 5535300 5535500 5535700 2061400 2061500 2061600 2061700 2062000 2062400 0900356 0900357 0900358 0900359 0900360 0900361 S 06 M - 1/4
y
x Disc guide
x {
y Spring
1 2
1 2
/ " - 2"
Subject to change
02/00
Honeywell AG P.O. Box 1347 D-74819 Mosbach (Germany) (+49) 0 62 61/8 10 Fax (+49) 0 62 61/8 13 09
16 12
http://europe.hbc.honeywell.com