Non return valve with female thread


Product specification sheet
Application RV 280 non return valves are for use as an independent means of preventing reverse water flow. They can be used for commercial, industrial or similar water supply systems where reverse flow of water must be prevented. The classifications of safety devices to meet these requirements are specified in DIN 1988, Part 4. Special Features q q q q q q Universal application Suitable for installation in any orientation Creates no shock pressure loadings Meets KTW requirements Reliable, tried and tested Low pressure loss

Range of Application Medium Water, compressed air, medium and light fuel oils, kerosene, petroleum with less than 15% aromatic content. Not suitable for gaseous mediums below 0.5 bar, steam, heavy oils and benzole Operating pressure Technical Data Operating temperature Water up to 75 C (short term up to 90 C) Compressed air and other mediums up to 70 C Opening pressure Connection sizes Materials q q q q q q Brass housing Brass union nut High quality synthetic material disc guide and disc NBR lip sealing ring Stainless steel spring High grade synthetic material blanking plugs Approximately 0.05 bar
1 2

Construction The non return valve comprises: q q q q q q q Housing with test and drain taps (1/2" device with test tap only) Non return valve insert Union connector with female thread Blanking plugs Disc guide Spring Disc with lip sealing ring

Maximum 16.0 bar

/ " - 2"

Subject to change

02/00

13

Non return valve RV 280


Method of Operation Spring loaded non return valves have a moving seal disc which is lifted off the seat by a greater or lesser amount depending on the flow rate through the valve. If the flow falls towards zero, then the spring pushes the disc back onto the seat and seals the waterway. To ensure continuing correct function it is recommended that non return valves be regularly checked and maintained (as specified in DIN 1988 Parts 2 and 8). Options RV 280-. . . A = Standard version Special versions available on request Connection size
1 4

v v
h Rp

Connection sizes Rp Weight (Approx. kg) Dimensions (mm) L h sw Test and drain plugs R* kvs-value Nominal flow rate (m3/h) at Dp = 0.15 bar
* Test plug only

14

Honeywell AG . Mosbach

v v
/"
1 4

v v
L " 0.2 65 29 27 1/4" 4.5 1.7
1/2

" 0.3 75 32 32 1/4" 9.1 3.5

3/4

1" 0.5 93 35 41 1/4" 17.0 6.6

1 1/4" 0.8 110 43 50 1/4" 28.0 10.8

1 1/2" 1.0 120 47 55 1/4" 38.0 14.7

2" 1.9 150 55 70 1/4" 60.0 23.2

Subject to change

02/00

Non return valve RV 280

Installation Example

Installation Guidelines q If possible install in horizontal pipework with test and drain plugs downwards This position is best for draining q Fit isolating valves Isolating valves provide optimal serviceability q Ensure good access Simplifies maintenance and inspection q For systems with water meters, install immediately afterwards (permitted by draft Euronorm) Protects against backflow from water systems

Typical Applications Type RV 280 non return valves are suitable for use as a safety device on any water installation as specified in DIN 1988, Part 4. They can be used within the scope of their specification. The following are some typical uses for RV 280 non return valves: q In central water supply systems q After a water meter q As a safety device up to risk Class 2 of DIN 1988, Part 4 q Downstream of pumping installations q Upstream of water heating installations

Flow Diagram
[m3/h]100 80 60 40 30 20 10 8 6 4 3 2 1 0,8 0,6 0,4 0,3 0,2 0,1 0,3 0,03 0,4 0,04 0,5 0,6 0,7 0,8 0,05 0,06 0,07 0,08 1 0,1 1,5 0,15 2 0,2 3 0,3 4 0,4 5 0,5 8 6 7 0,6 0,7 0,8 10[mWS] 1[bar

R 2" R 11/2" R 11/4" R 1" R 3/4" R 1/2"

Durchflumenge V Flow rate V

Pressure drop Dp
Subject to change 02/00 Honeywell AG . Mosbach

15

Non return valve RV 280


Spare Parts - RV 280 non return valves (Form 1966 onwards) Description Nominal size /" /" 1" 11/4" 11/2" 2"
3 4 1 2

Part number 5534900 5535100 5531500 5535300 5535500 5535700 2061400 2061500 2061600 2061700 2062000 2062400 0900356 0900357 0900358 0900359 0900360 0900361 S 06 M - 1/4

y
x Disc guide

x {

y Spring

/" /" 1" 11/4" 11/2" 2"


3 4

1 2

z Valve disc complete

/" /" 1" 11/4" 11/2" 2"


3 4 1 2

1 2

{ Blanking plug with seal ring (pack of 5)

/ " - 2"

Subject to change

02/00

Honeywell AG P.O. Box 1347 D-74819 Mosbach (Germany) (+49) 0 62 61/8 10 Fax (+49) 0 62 61/8 13 09

16 12

http://europe.hbc.honeywell.com

Anda mungkin juga menyukai