ESTIMATE BASED ON S.O.R. FOR ROAD & BRIDGE WORKS ISSUED BY ENGINEER-IN-CHIEF M.P.P.W.D.

BHOPAL INFORCE FROM 1ST APRIL, 2009 PIU-Khandwa ESTIMATE FOR SUBMERSIBLE BRIDGE ACROSS AJNAL RIVER ON DHAMANGAON TO BADNAGAR RAYAT 8 SPANS @ 1OM.=80M. ABUTMENT 2 X 5.0 + RETURN 2 X 3.6 = 17.2M. WALL TYPE PIER & R.C.C. BOX TYPE ABUTMENT & COUNTERFORT & TIEBACK TYPE RETURN Name of bridge:-AJNAL RIVER ON DHAMANGAON TO BADNAGAR RAYAT Block:-Punasa Package no. MP-21 BO1 Ref. Of S.No. C.S.R. Description PAC-155.29 Lacs Quantity Unit

Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and 1.1 A other deleterious matter, dressing of sides and bottom and backfilling with approved material etc. and as per relevant clauses of section 300 & 2100 in 1.1 A (I) Ordinary Soil 1.1 A (I) (I) upto 3 m depth 1076 1.1 A (I) (ii) 3 m to 6 m depth 1209 1.1 A (III) Hard rock ( requiring blasting ) 1.1 A (III) (i) Depth upto 3 m from av. Ground level 448 Add extra as follows in the rates of the above 1.1B items if dewatering is resorted to 1.1B (b) 3m. To 6m. Depth 1209 1.1B (III) Hard rock ( requiring blasting ) 448 Providing Plain cement concrete M-10 nominal 21.3 mix in foundation as per relevant clauses of 59 sections 1500, 1700 and 2100. Providing and laying Plain/Reinforced cement concrete in sub-structure or complete RCC Box section as per drawing and technical 32.5 (G) specifications and as per relevant clauses of sections 1500, 1700 & 2200 in (Height above average ground level) 2.5 (G) PCC Grade M15 2.5 (G) (a) Height upto 5m 636 (b) Height beyond 5m and upto 10m 207 Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per 55 drawing and technical specifications and as per relevant clauses of sections 1600.

Cum Cum Cum

Cum

cum cum

42.6

tonne

53.1 3.1 C a) 63.2

72.8

Providing and laying Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification and as per relevant clauses of sections 1500, 1700 and 2300 in RCC Grade M30 Height upto 5m 436 a) Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications as per 39 relevant clauses of section 1600 of specifications.. Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure 130 with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications and as per clause 2706 of specifications. Providing Back filling behind abutment, wing wall and return wall with Granular Material complete as per drawing and Technical 357 specification and as per relevant clauses 305 of specifications and as per appendix 6 of IRC-78 Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MORTH specifications to a thickness of not less than 600 mm with smaller size towards the soil 86 and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification. Inside granular filling in abutment 600 Inside granular filling in return 80 Supplying, fitting and fixing in position true to line and level elastomeric bearings confirming to IRC:83:(Pt.II) section IX complete including all 187200 accessories as per drawing and specifications as per section 2000. Stopper bearing 28160 Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical 55 Specifications and as per relevant clauses of sections 1500, 1700 and Clause 2702 of specifications.. Providing Drainage Spouts complete as per drawing and Technical specification and as per 16 clause 2705 of specifications. Providing and laying Reinforced cement concrete approach slab in M-25 grade concrete including reinforcement and formwork complete as per

cum tonne

metre

82.9

cum

92.10

cum

Cum Cum Cu.Cm. Cu.Cm.

102.14

113.4

cum

123.9

Nos.

133.11

18

cum

133.11

drawing and Technical specification and as per relevant clauses of section 1500, 1600, 1700 and clause 2704 of specifications.. Providing & fixing 2 mm thick and 200mm wide corrugated copper plate in expansion joint complete as per drawing & Technical Specification and as per relevant clauses of section 2600. Providing & fixing 20 mm thick & 25cm deep compressible fibre board in expansion joint complete as per drawing & Technical Specification and as per relevant clauses of section 2600. Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight and as per relevant clauses of section 2600.

18

cum

143. 14(i)

76

metre

153. 14(ii)

76

metre

163. 14(iv)

76

metre

173.21

Testing of span of bridge for deflection due to live load with platforms for loading arrangements 77 apparatus for meaurement including unloading etc. complete as per approved drawing. Providing and fixing in position Marble Plates of 3.23size 0.9 m. x 1.2 m. with inscribed details as per 2 detailed drawings.

tonne

18

each

19

Providing and fixing of retro-reflecorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a 8.3mild steel angle iron post 75mm x 75mm x 6 mm (height from crown level of the road and bottom of the sign board shall not be less than 1.5m) firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cm x 45 cm x 60xm,

8.3 (iv) 208.6

80cm x 60cm rectangular 2 Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces and as per relevant 390 clauses of section-800 & I.R.C.-67 including cost of paint etc. complete. Reinforced cement concrete M15 grade boundary pillars of standard design as per IRC:25-1967, 104 fixed in position including finishing and lettering but excluding painting) Tubular Steel Railing on Medium Weight steel channel ( ISMC series) 100 mm x 50 mm (Providing, fixing and erecting 50 mm dia GI pipe (medium class) railing in 3 rows duly painted on

sqm

218.13

each

228.16

234.1

4.1 (a) EXTRA

medium weight steel channels (ISMC series) 100 194 mm x 50 mm, 1.2 metres high above ground, 2 m centre to centre, complete as per approved drawings as per relevant clauses of section-800 of specifications. Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with on prepared surface, mixing by mix in place method at OMC, and compacting with vibratory roller to achieve the desired density, complete in all respect and as per relevant clauses of section-400. Boulder laid dry without wire crates. 1080 Provision of Barriers on both banks of submersible Bridge. Excavation for roadway in soil including loading in truck for carrying of cut earth to embankment 3000 site with all lifts and lead upto1000 metres and as per relevant clauses of section-300. Construction of embankment/subgrade with approved material/selected soil having CBR >5 (Unless specified othewise in the cotract) obtained from excavation of borrow pits i/c all lifts & leads upto 250 M. i/c grading to required slope 2000 & camber and compacting using vibratory roller of 80 to 100 kN static weight to meet requirement of Table 300.1, 300.2 and as per relevant clause of section 300. For Grading I material Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with on prepared surface, mixing by mix in place method at OMC, and compacting with 250 vibratory roller to achieve the desired density, complete in all respect and as per relevant clauses of section-400. for grading -1 material Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding materials to fill up the interstices of coarse aggregate, watering and compacting to the required density and as per relevant clauses of section-400. Grading - II 164 Construction of dry lean cement concrete Subbase over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than

metre

Cum

24

3.1

cum

25

3.12

cum

26

4.1

Cum

27

4.3

4.3 (ii)

cum

28

6.1

29

6.2

150 kg/ cum, optimum moisture content to be 328 determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing and as per relevant clauses of section-600. Deduct from Item No.6.1 above if paver with electronic sensor, vibratory roller are not used -328 and laying, compaction is done by any other method. . Construction of dowel jointed, plain cement concrete pavement in M-40 grade concrete over a prepared sub base with 43 or higher grade cement, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver with electronic sensor, spread, compacted and finished in a continuous operation including provision of contraction, 437 expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, placing of dowel bar and tie rod, admixtures as approved, curing compound, finishing to lines and grades as per approved drawings as per IRC-15 2002 and as per relevant clauses of section-602 of specifications complete but excluding cost of steel in dowel bar and tie rod etc. Deduct from Item No.6.3 above if paver with electronic sensor is not used and laying, compaction is done by any other method (The acceptance criteria regarding level, thickness, -437 surface regularity, texture finish, strength of concrete and all other quality control measures shall be the same as in case of machine laid work.) Add extra in Item No.6.3 & 6.7 above for the cost of steel in dowel bar and tie rod etc. required as per design. Tor steel Provdiing and laying Plain/Reinforced cement concrete in open foundation including form work shuttering etc. complete as per drawing and technical specifications and as per relevant clauses of sections 1500, 1700 & 2100 with . PCC Grade M15 Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications and as per relevant clauses of section 2500. 154 4.5

cum

cum

30

6.3

cum

316.4

cum

326.9 ii)

MT

331.6

1.6 (a)

cum

34B4-'4.4

a) 35B4-'4.5

Stone/Boulder Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification and as per relevant clauses of section 2500.

165 83

cum cum

Anda mungkin juga menyukai