Anda di halaman 1dari 14

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 600 52 25Hz Client:

Client Number: Contact: P2 [kW] 55 55 55 55 75 75

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski p max [bar] 16 16 16 16 16 16 Q actual [m/h] 588 588 588 588 588 588 H actual [m] 51 51 51 51 51 51

Product name 4 x NK 80-250 4 x NK 80-250 4 x NBG 125-80-250 4 x NB 80-250 4 x NB 80-250 4 x NBG 125-80-250

Phase 3 3 3 3 3 3

U [V] 380-415 D / 660-690 Y 380-415 D / 660-690 Y 380-415 D / 660-690 Y 380-415 D / 660-690 Y 380-415 D / 660-690 Y 380-415 D / 660-690 Y

Pump outlet DN 80 DN 80 DN 80 DN 80 DN 80 DN 80

Printed from Grundfos CAPS

1/14

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 600 52 25Hz Client: Client Number: Contact:

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski
Single Price

Position

Qty.

Description

NK 80-250 -B BAQE Non-self priming, single-stage centrifugal pump according to EN. The pump is for the pumping of thin, clean or slightly contaminated liquids without abrasive or long-fibred solids. Pump and 3-phase AC motor are mounted as separate units on a common baseplate and connected via a Spacer-coupling. The impeller is hydraulically as well as dynamically balanced. The pump has the following characteristics: - flange dimensions according to EN 1092-2, - Cast iron volute pump housing, - stainless steel shaft and Bronze impeller and bronze wear rings, - unbalanced mechanical shaft seal according to EN 12756. Liquid: Pumped liquid: Liquid temperature range: Technical: Speed for pump data: Rated flow: Actual calculated flow: Rated head: Resulting head of the pump: Actual impeller diameter: Calculated impeller diameter: Shaft seal: Curve tolerance: Materials: Pump housing:

Price on request

Heating water 0 .. 120 C

2975 rpm 203.4 m/h 150 m/h 68.9 m 51 m 220 mm 220 mm BAQE ISO 9906 Annex A

Impeller:

Cast iron EN-JL1040 DIN W.-Nr. A48-40 B ASTM Bronze 2.1096.01 DIN W.-Nr. B584-C83600 ASTM

Installation: Maximum ambient temperature: System pressure: Maximum operating pressure: Min inlet pressure: Flange standard:
Printed from Grundfos CAPS

40 C 16 bar 16 bar 0.025 bar EN

2/14

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 600 52 25Hz Client: Client Number: Contact:

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski
Single Price

Position

Qty.

Description

Pump inlet: Pump outlet: Pressure stage: Coupling type: Electrical data: Motor type: Efficiency class: Number of poles: Rated power - P2: Mains frequency: Rated voltage: Rated current: Starting current: Cos phi - power factor: Rated speed: Motor efficiency at full load: Motor efficiency at 3/4 load: Enclosure class (IEC 34-5): Insulation class (IEC 85): Others: Net weight: Gross weight: Shipping volume:

DN 100 DN 80 PN16 Spacer

250M 1 2 55 kW 50 Hz 3 x 380-415 D / 660-690 Y V 93 / 53.7 A 680 % 0,90 2980 rpm 95,3 % 95,3 % IP55 F

706 kg 758 kg 1.57 m

Printed from Grundfos CAPS

3/14

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 600 52 25Hz Client: Client Number: Contact:

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski
Single Price

Position

Qty.

Description

NK 80-250 -B BAQE

Price on request

Note! Product picture may differ from actual product

Non-self priming, single-stage centrifugal pump according to EN. The pump is for the pumping of thin, clean or slightly contaminated liquids without abrasive or long-fibred solids. Pump and 3-phase AC motor are mounted as separate units on a common baseplate and connected via a Spacer-coupling. The impeller is hydraulically as well as dynamically balanced. The pump has the following characteristics: - flange dimensions according to EN 1092-2, - Cast iron volute pump housing, - stainless steel shaft and Bronze impeller and bronze wear rings, - unbalanced mechanical shaft seal according to EN 12756. Liquid: Pumped liquid: Liquid temperature range: Technical: Speed for pump data: Rated flow: Actual calculated flow: Rated head: Resulting head of the pump: Actual impeller diameter: Calculated impeller diameter: Shaft seal: Curve tolerance: Materials: Pump housing:

Heating water 0 .. 120 C

2975 rpm 203.4 m/h 150 m/h 68.9 m 51 m 220 mm 220 mm BAQE ISO 9906 Annex A

Impeller:
Printed from Grundfos CAPS

Cast iron EN-JL1040 DIN W.-Nr. A48-40 B ASTM Bronze

4/14

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 600 52 25Hz Client: Client Number: Contact:

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski
Single Price

Position

Qty.

Description

2.1096.01 DIN W.-Nr. B584-C83600 ASTM Installation: Maximum ambient temperature: System pressure: Maximum operating pressure: Min inlet pressure: Flange standard: Pump inlet: Pump outlet: Pressure stage: Coupling type: Electrical data: Motor type: Efficiency class: Number of poles: Rated power - P2: Mains frequency: Rated voltage: Rated current: Starting current: Cos phi - power factor: Rated speed: Motor efficiency at full load: Motor efficiency at 3/4 load: Enclosure class (IEC 34-5): Insulation class (IEC 85): Others: Net weight: Gross weight: Shipping volume:

40 C 16 bar 16 bar 0.025 bar EN DN 100 DN 80 PN16 Spacer

250M 1 2 55 kW 50 Hz 3 x 380-415 D / 660-690 Y V 93 / 53.7 A 680 % 0,90 2980 rpm 95,3 % 95,3 % IP55 F

706 kg 758 kg 1.57 m

Printed from Grundfos CAPS

5/14

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 600 52 25Hz Client: Client Number: Contact:
H (m) 100 % 60 2975 rpm 203.4 m/h 150 m/h 68.9 m 51 m 220 mm 220 mm BAQE 32 mm ISO 9906 Annex A

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski
NK 80-250/220 Losses in fittings and valves not included Q = 588 m/h H = 51 m n = 4 x 89 % switch-on at Pumped liquid = Heating water 1

Description Product name: Product No: EAN number: Technical: Speed for pump data: Rated flow: Actual calculated flow: Rated head: Resulting head of the pump: Actual impeller diameter: Calculated impeller diameter: Shaft seal: Shaft diameter: Curve tolerance: Materials: Pump housing:

Value NK 80-250 -B BAQE < > < >

50

40 3 4 20

30

Impeller:

Material code: Installation: Maximum ambient temperature: System pressure: Maximum operating pressure: Min inlet pressure: Flange standard: Pump inlet: Pump outlet: Pressure stage: Coupling type: Neck ring(s): Liquid: Pumped liquid: Liquid temperature range: Electrical data: Motor type: Efficiency class: Number of poles: Rated power - P2: Mains frequency: Rated voltage: Rated current: Starting current: Cos phi - power factor: Rated speed: Motor efficiency at full load: Motor efficiency at 3/4 load: Enclosure class (IEC 34-5): Insulation class (IEC 85): Motor protec: Motor No: Motor range: Others: Net weight: Gross weight: Printed from Grundfos CAPS

Cast iron EN-JL1040 DIN W.-Nr. A48-40 B ASTM Bronze 2.1096.01 DIN W.-Nr. B584-C83600 ASTM B

10 Eta pump = 78.1 % Eta pump+motor = 73.8 % 500 600 700 800 Q(m/h) P1 P2

0 0 P (kW) 160 120 80 40 0

100

200

300

400

40 C 16 bar 16 bar 0.025 bar EN DN 100 DN 80 PN16 Spacer neckring(s)

Heating water 0 .. 120 C

250M 1 2 55 kW 50 Hz 3 x 380-415 D / 660-690 Y V 93 / 53.7 A 680 % 0,90 2980 rpm 95,3 % 95,3 % IP55 F PTC 83A15138 Premium

706 kg 758 kg

6/14

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 600 52 25Hz Client: Client Number: Contact:

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski

Description Shipping volume:

Value 1.57 m

Printed from Grundfos CAPS

7/14

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 600 52 25Hz Client: Client Number: Contact:

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski

H (m) 70 100 % 60

NK 80-250/220 Losses in fittings and valves not included Q = 588 m/h H = 51 m n = 4 x 89 % switch-on at Pumped liquid = Heating water

50

40

30 4 20

10 Eta pump = 78.1 % Eta pump+motor = 73.8 % 700 800 Q(m/h)

0 0 P (kW)

100

200

300

400

500

600

P1 P2 160

120

80

40 P2 = 105 kW P1 = 111 kW 8/14

0
Printed from Grundfos CAPS

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 600 52 25Hz Client: Client Number: Contact:

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski I (A) 200 eta cos phi

cos phi eta 1

4 NK 80-250/220 speed controlled + 250M

55 kW 3* 400 V, 50 Hz

0.8

160

0.6

120

0.4

80

0.2

40

0 0 n (rpm) 2800 2600 2400 2200 2000 1800

10

20

30

40

50

60

70 P2(kW) n

0 P1 (kW) 120

P1

80

40

0
Printed from Grundfos CAPS

9/14

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 600 52 25Hz Client: Client Number: Contact:

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski

8x19

670 8x19 = 28 1200 90 = 752 100

1622

Note! All units are in [mm] unless others are stated. Printed from Grundfos CAPS

125

1800

730

80

100
10/14

360

280

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 600 52 25Hz Client: Client Number: Contact:

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski

+T

+T

+T

TO AMPLIFIER RELAY

L1

L2

L3

+T

+T

+T

TO AMPLIFIER RELAY

L1

L2

L3

Note! All units are in [mm] unless others are stated. Printed from Grundfos CAPS

IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY THERMISTORS PTC ACCORDING TO DIN 44082

11/14

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 600 52 25Hz Client: Client Number: Contact:
Sizing result Type Main Circulator flow or return Your Requirements Allowed flow undersize Flow (Q) Head (H) Max. inlet pressure Max. liquid temperature Max. operation pressure Min. inlet pressure Control Mode Decrease at low flow Frequency Converter Edit Load Profile Consumption Q1 Consumption Q2 Consumption Q3 Consumption Q4 Heating season Load profile Time T1 Time T2 Time T3 Time T4 Configuration Of these: number of standby pumps Preferred number of poles Total number of pumps Pump design End Suction, Close Coupled End Suction, Long Coupled Impeller trim allowed Inline Inline Canned Rotor P2 according to ISO 5199 With spacer coupling Operational Conditions Ambient temperature Frequency Min. power limit for SD start Phase Voltage Hit list settings Allow uncontrolled Calculation period Energy price Evaluation criterion Max. hits per product group Max. hits total Load Profile Flow Head 1 98 98 2 75 78 3 50 63 4 25 53 % % Parallel 1 2 4 Yes Yes Yes Yes Yes No No 20 C 50 Hz 5.5 kW 1 or 3 1 x 230 or 3 x 400 V No 15 years 0.1 EUR/kWh Price + energy costs 2 8 Prop. pressure, Ext. 50 % External for all pumps 600 m/h 450 m/h 300 m/h 150 m/h 185 days Standard profile 266 h/a 666 h/a 1554 h/a 1954 h/a 2% 600 m/h 52 m 2 bar 70 C 10 bar 1.5 bar

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski

Input Select Type of Installation

NK 80-250/220 Impeller: 220 mm Quantity 4 Supply 380-415 D/660-690 Y V Motor 55 kW speed controlled Flow 588 m/h ( max. +3 %) Switch-on at 184 m/h Head 51 m ( max. +9 %) Max. velocity 8.12 m/s Min.inlet pressure 0.025 bar ( 70 C, against atmosphere) Power P1 110 kW Power P2 104 kW Eta pump 78.1 % Eta motor 95.2 % Eta pump+motor 74.4 % =Eta pump * Eta motor Eta total 65.2 % =Eta relative to the duty point Energy consumption 188190 kWh/Year CO2 emission 107000 kg/Year Price On request EUR Energy cost 18819 EUR /Year Price + energy costs On request EUR /Years All pumps with variable speed; the required control (modified Control 2000 ME) is available on request Flow is too high during operation! Minimum number of pumps in operation is increased

H (m) 100 % 60 50 40 30 4

NK 80-250/220 Losses in fittings and valves not included

1 2 3

20 Q = 588 m/h H = 51 m 10 n = 4 x 89 % switch-on at Eta pump = 78.1 % Pumped liquid = Heating water Eta pump+motor = 73.8 % 0 0 100 200 300 400 500 600 700 Q(m/h) P (kW) P1 P2 160 120 80 40 0

Printed from Grundfos CAPS

12/14

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 600 52 25Hz Client: Client Number: Contact:

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski

Load profile Q 600.0 [m/h] 450.0

300.0

150.0

266

932 1 98 98 125 266 33299 4 2 75 78 75.3 666 50117 3 3 50 63 42.6 1554 66223 3

2486 4 25 53 19.7 1954 38547 2 52 m 600 m/h % % kW h/Year kWh/Year

t 4440 [h]

Flow Head P1 Time Energy consumption Quantity Total head Dimensioning flow

Printed from Grundfos CAPS

13/14

Company name: Created by: Phone: Fax: Date: KOGEL SEVER Project: Reference Number: 600 52 25Hz Client: Client Number: Contact:

RUDARSKI INSTITUT Goce Vasilevski 389 2 2447627 02.10.2013

A.Kechovski

Order Data:
NK 80-250 -B BAQE Amount: Product No: Rated flow: Rated head: Actual calculated flow: Resulting head of the pump: Shaft seal: Coupling type: Actual impeller diameter: Impeller material: Pump housing material: Motor No: Motor range: Mains frequency: Rated voltage: Rated power - P2: Price: Total: Price on request ;

4 < > 203.4 m/h 68.9 m 150 m/h 51 m BAQE Spacer 220 mm Bronze Cast iron 83A15138 Premium 50 Hz 3 x 380-415 D / 660-690 Y V 55 kW On request

Printed from Grundfos CAPS

14/14

Anda mungkin juga menyukai