GEP110

Diesel Generator Set


Exclusively from your Caterpillar® dealer

Output Ratings

Generating Set Model Prime* Standby*

380-415V,50Hz 100.0 kVA 110.0 kVA


80.0 kW 88.0 kW

480V, 60 Hz 113.0 kVA 125.0 kVA


90.4 kW 100.0 kW

* Refer to ratings definitions on page 4.


Ratings at 0.8 power factor.

Technical Data
Engine Make & Model: Perkins 1006TG2A

Alternator Model: LL3014B

Base Frame Type: Heavy Duty Fabricated Steel

Circuit Breaker Type: 3 Pole MCB / 3 Pole MCCB

Frequency: 50 Hz 60 Hz

Engine Speed: RPM 1500 1800

Fuel Tank Capacity: litres (US gal) 230 (60.8)

Fuel Consumption, Prime: l/hr (US gal/hr) 22.8 (6.0) 26.4 (7.0)

Fuel Consumption, Standby : l/hr (US gal/hr) 25.4 (6.7) 29.2 (7.7)
Engine Techncial Data
Physical Data Lubrication system
Manufacturer: Perkins Oil Filter Type: Spin-On, Full Flow
Model: 1006TG2A Total Oil Capacity l (US gal): 16.1 (4.3)
No. of Cylinders/Alignment: 6 / In Line Oil Pan l (US gal): 13.1 (3.5)
Cycle: 4 Stroke Oil Type: AP1CD 15W-40
Induction: Turbocharged Cooling Method: Water

Cooling Method: Water


Governing Type: Mechanical Performance 50 Hz 60 Hz
Governing Class: ISO 8528 G2
Engine Speed: RPM 1500 1800
Compression Ratio: 16.0:1
Gross Engine Power: kW (hp)
Displacement: l (cu.in) 6.0 (365.5)
-Standby: 105.0 (141.0) 125.0 (168.0)
Bore/Stroke: mm (in) 100.0 (3.9)/127.0 (5.0)
-Prime: 95.7 (128.0) 114.0 (153.0)
Moment of Inertia: kg m² (lb. in²) 1.61 (5502)
BMEP: kPa (psi)
Engine Electrical System: -Standby: 1404.0 (203.6) 1393.0 (202.0)
-Voltage/Ground: 12/Negative -Prime: 1279.0 (185.5) 1270.0 (184.2)
-Battery Charger Amps: 55 Regenerative Power: kW 12.6 16.2
Weight: kg (lb) - Dry: 586 (1292)
- Wet: 623 (1373)
Fuel System
Fuel Filter Type: Replaceable Element
Air System 50 Hz 60 Hz Recommended Fuel: Class A2 Diesel
Fuel Consumption: l/hr (US gal/hr)
Air Filter Type: Replaceable Element
110% 100% 75% 50%
Combustion Air Flow:
Load Load Load Load
m³/min (cfm) -Standby: 6.0 (212) 7.6 (268)
Prime
-Prime: 5.7 (201) 7.2 (254)
50 Hz 25.4 (6.7) 22.8 (6.0) 16.9 (4.5) 11.9 (3.1)
Max. Combustion Air Intake
60 Hz 29.2 (7.7) 26.4 (7.0) 20.1 (5.3) 14.7 (3.9)
Restriction: kPa (in H2O) 5.0 (20.1) 5.0 (20.1)
Radiator Cooling Air Flow:
Standby
m³/min (cfm) 192.0 (6780) 244.0 (8617)
50 Hz 25.4 (6.7) 18.6 (4.9) 12.8 (3.4)
External Restriction to
60 Hz 29.2 (7.7) 22.1 (5.8) 15.8 (4.2)
Cooling Air Flow: Pa (in H2O) 125 (0.5) 125 (0.5)
(based on diesel fuel with a specific gravity of 0.85 and conforming to
BS2869, Class A2)

Cooling System 50 Hz 60 Hz Exhaust System 50 Hz 60 Hz


Cooling System Capacity: Silencer Type: Level 1
l (US gal) 27.7 (7.3) 27.7 (7.3) Silencer Noise Reduction SD80 (1)
Water Pump Type: Centrifugal Pressure Drop Across
Heat Rejected to Water & Silencer System: kPa (in Hg) 4.00 (1.181) 4.00 (1.181)
Lube Oil: kW (Btu/min) Silencer Noise Reduction
-Standby: 69.8 (3969) 78.8 (4481) Level: dB 18 18
-Prime: 62.6 (3560) 70.8 (4026) Max. Allowable Back
Heat Radiation to Room: Pressure: kPa (in. Hg) 6.0 (1.8) 6.0 (1.8)
kW (Btu/min) -Standby: 48.3 (2747) 44.3 (2519) Exhaust Gas Flow:
-Prime: 39.3 (2235) 35.1 (1996) m³/min (cfm) -Standby: 17.6 (622) 21.9 (773)
Radiator Fan Load: kW (hp) 2.8 (3.8) 4.9 (6.6) -Prime: 16.1 (569) 19.5 (689)
Exhaust Gas Temperature: °C (°F)
m³/min (cfm) -Standby: 585 (1085) 581 (1077)
Cooling system designed to operate in ambient conditions up to 50°C -Prime: 550 (1023) 541 (1006)
(122°F). Contact your local Olympian dealer for power ratings at specific
site conditions.

Consult your Olympian representative for more information


Alternator Performance Data
50 Hz 60 Hz
Data Item 415/240V 400/230V 380/220V 220/127V 480/277V 380/220V 240/120V 230/115V 440/254V
230/115V 220/110V 240/139V 220/110V 208/120V 220/127V
200/115V

Motor Starting
Capability* kVA 187 176 160 208 206 136 160 149 177

Short Circuit
Capacity** % 300 300 300 300 300 300 300 300 300

Reactances:
Per Unit

Xd 3.200 3.440 3.810 2.840 3.240 5.080 4.310 4.660 3.850

X'd 0.120 0.130 0.150 0.110 0.130 0.200 0.170 0.180 0.150

X''d 0.074 0.080 0.089 0.066 0.075 0.118 0.100 0.108 0.090

Reactances shown are applicable to standby ratings.


* Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.
** With optional Permanent Magnet generator or AREP excitation.

Alternator Technical Data

Physical Data Operating Data

Manufacturer: OLYMPIAN Overspeed: RPM 2250

Model: LL3014B Voltage Regulation (steady state) (% ): +/- 0.5

No. of Bearings: 1 Wave Form NEMA = TIF: 50

Insulation Class: H Wave Form IEC = THF: 2.0%

Winding Pitch - Code: 2/3 - 6 Total Harmonic Content LL/LN: 4.0%

Supression is in line with European


Wires: 12 Radio Interference: Standard EN61000-6

Ingress Protection Rating: IP23 Radiant Heat: kW (Btu/min)

Excitation System: -50 Hz: 10.7 (608)


SHUNT

-60 Hz: 12.0 (682)


AVR Model: R250

Consult your Olympian representative for more information


1800

Technical Data
3 Phase Ratings and Performance at 50 Hz, 1500 RPM 3 Phase Ratings and Performance at 60 Hz, 1500 RPM

Voltage Prime Standby Voltage Prime Standby


kVA kW kVA kW kVA kW kVA kW
415/240V 100.0 80.0 110.0 88.0 480/277V 113.0 90.4 125.0 100.0
400/230V 100.0 80.0 110.0 88.0 220/127V 113.0 90.4 125.0 100.0
380/220V 100.0 80.0 110.0 88.0 380/220V 111.0 88.8 122.0 97.6
230/115V 100.0 80.0 110.0 88.0 240/120V 113.0 90.4 125.0 100.0
220/127V 100.0 80.0 110.0 88.0 230/115V 113.0 90.4 125.0 100.0
220/110V 100.0 80.0 110.0 88.0 440/254V 113.0 90.4 125.0 100.0
200/115V 100.0 80.0 110.0 88.0 220/110V 111.0 88.8 122.0 97.6
208/120V 113.0 90.4 125.0 100.0
240/139V 113.0 90.4 125.0 100.0

Weights & Dimensions


Weights: kg (lb) Dimensions: mm (in)
Net (+ lube oil) 1240 (2734) Length 2481 (97.7)
Wet (+ lube oil & coolant) 1260 (2778) Width 746 (29.4)
Fuel, lube oil & coolant 1454 (3206) Height 1435 (56.5)

Note: General configuration not to be used


for installation. See general dimension
drawings for detail.

Definitions General Data


Standby Rating Documents
These ratings are applicable for supplying continuous electrical Operation and maintenance manuals provided.
power (at variable load) in the event of a utility power failure. No Wiring diagrams included.
overload is permitted on these ratings. The alternator on this model
is peak continuous rated (as defined in ISO 8528-3).
Quality Standards
BS4999, BS5000, BSEN60034, BSEN61000, IEC60034.
Prime Rating
These ratings are applicable for supplying continuous electrical
power (at variable load) in lieu of commercially purchased power.
There is no limitation to the annual hours of operation and this Warranty
model can supply 10% overload power for 1 hour in 12 hours. All equipment carried full manufacturer's warranty.

Standard Reference Conditions


Note: Standard reference conditions 27°C (80°F) air Inlet Temp,
152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption
data at full laod with diesel fuel with spedcific gravity of 0.85 and
conforming to BS2869: 1998, Class A2.

Information contained in this publication may be considered confidential. www.CAT-ElectricPower.com


Discretion is recommended when distributing.
Materials and specifications are subject to change without notice. © 2008 Caterpillar
Market: International
CAT, CATERPILLAR,OLYMPIAN, their respective logos and ''Caterpillar Yellow'', as well as corporate and product All rights reserved.
LEHF1192-08 Printed in U.S.A.