http://catalog.phoenixcontact.net/phoenix/treeViewClick.do?UID=1518025
Bus system cable, PROFIBUS, 2-position, PUR halogen-free, Violet, RAL 4001, shielded, Plug straight M12-SPEEDCON, B-coded, on Free cable end, Cable length: 2 m
sales group Pack Customs tariff Gross weight in pieces Net weight per piece Catalog page information
D117 1 Pcs. 85444290 0.1478 KG 0.1426 KG Page 393 (PC-2011) http:// www.download.phoenixcontact.com Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation. The General Terms and Conditions of Use apply to Internet downloads.
Technical data General data Rated current at 40C Rated voltage Number of positions Volume resistance 4A 250 V 2 5 m
http://catalog.phoenixcontact.net/phoenix/treeViewClick.do?UID=1518025
Insulation resistance Length of cable Stripping length of the free conductor end Ambient temperature (operation) General characteristics Coding Surge voltage category Pollution degree Degree of protection Contact material Contact surface material Contact carrier material Material of grip body Material, knurls Status display Conductor data Cable type Cable type (abbreviation) UL AWM style Conductor cross section AWG signal line Conductor structure signal line Core diameter including insulation Wire colors Overall twist Shielding Optical shield covering External sheath, color External cable diameter D Number of bending cycles Minimum bending radius, drag chain applications Traversing path Traversing rate
B - inverse II 3 IP65 IP67 CuSn Ni/Au PA 66 TPU, hardly inflammable, self-extinguishing Zinc die-cast, nickel-plated No
PROFIBUS 910 21198 (80C/300 V) 2x 0.25 mm (signal line) 24 19x 0.13 mm 2.55 mm 0.07 mm Red, green 2 cores with 2 fillers to the core Plastic-coated aluminum foil, tinned copper braided shield 85 % Violet, RAL 4001 7.8 mm 0.2 mm 2000000 8xD 4.5 m 3 m/s
http://catalog.phoenixcontact.net/phoenix/treeViewClick.do?UID=1518025
Acceleration Outer sheath, material Material conductor insulation Conductor material Insulation resistance Conductor resistance Working capacitance Wave impedance Shield attenuation Nominal voltage, conductor Test voltage Core/Core Test voltage Core/Shield Flame resistance Other resistance Ambient temperature (operation)
3 m/s PUR Foamed PE Tin-plated Cu litz wires 5 G*km 157.2 /km 30 nF nom. 150 10 % (3 MHz ... 20 MHz) 4.9 dB (at 16 MHz) 30 V 1500 V (50 Hz, 1 min.) 1500 V (50 Hz, 1 min.) UL 1581, Sec. 1060 (FT-1) IEC 60332-1 Low adhesion -40 C ... 80 C (cable, fixed installation) -30 C ... 70 C (cable, flexible installation)
Certificates / Approvals
GOST
http://catalog.phoenixcontact.net/phoenix/treeViewClick.do?UID=1518025
Schematic diagram
PROFIBUS[910]
http://catalog.phoenixcontact.net/phoenix/treeViewClick.do?UID=1518025
Address
PHOENIX CONTACT Ind. Com. Ltda. Rua Gino Cesaro BR-05038-140 Sao Paulo-SP / 169 - gua Branca,Brazil Phone +55/11/3871-6400 Fax +55/11/3871-6401 http://www.phoenixcontact.com.br